Loading...
DRC Summary 12-18-2014 OFFICE OF COMMUNITY DEVELOPMENT . • > CITY HALL 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 C U P E RT 1 N tJJ (408)777-3308 • FAX(408)777-3333• planning�a�cupertino.org To: Mayor and City Council Members Planning Commissioners From: Gary Chao, Assistant Director of Community Development Date: December 22, 2014 Subj: REPORT OF DESIGN REVIEW COMMITTEE FINAL DECISIONS MADE December 18, 2014 Chapter 19.12.170 of the Cupertino Municipal code provides for Appeal of decisions made by the Design Review Committee 1. Application EXC-2014-13, Rago Neon (Armadillo Willy's), 10100 S De Anza Boulevard Description Sign Exception to allow a new wall sign with an exposed LED border at an existing restaurant Action The Design Review Committee approved the application on a 2-0-0 vote. This is effective October 18, 2014. The fourteen-calendar day appeal will expire on January 1, 2015— extended to January 8, 2015 due to the City's facility closure. Enclosures: Design Review Committee Report of December 18, 2014 Resolution No(s). 325 Plan set COMMUNITY DEVELOPMENT DEPARTMENT PLANNING DIVISION , � , CITY HALL 10300 TORRE AVENUE • CUPERTINO,CA 95014-3255 C U P E RT 1 N O (408)777-3308 •FAX(408)777-3333 DESIGN REVIEW COMMITTEE STAFF REPORT Agenda Item No. � Agenda Date:December 18, 2014 Application no: EXC-2014-13 Applicant: Tony Rago (Rago Neon, Inc. for Armadillo Willy's) Project Location: 10100 S De Anza Boulevard (APN 369-01-001) APPLICATION SUMMARY: Sign Exception (EXC-2014-13) to allow an exposed white LED border on a new wall sign. RECOMMENDATION: Staff recommends that the Design Review Committee approve the application per the draft resolution. PROJECT DATA: General Plan Desi ation Commercial/Office/Residential Zoning Designation P (CG, OP, Res)—Planned Development General Commercial, Office, and Residential S ecific Plan Area Heart of the Ci Existin Land Use Commercial restaurant(no chan e) Lot Size 26,136 s uare feet(.6 acres) Existing/I'ro osed ound si ns One existin round si Existin Pro osed wall signs No existin wall si ; one ro osed wall si Project Consistency with: General Plan Yes S ecific Plan Yes Zonin Yes, exce t for the si exce tion re uest Environmental Review Cate oricall Exem t er Section 15302, Class 2 of CEQA BACKGROUND: Site Description The subject property is located at the northeast corner of the S De Anza Boulevard and Scofield Drive intersection. To the north and east of the site is Cupertino City Center complex (including hotel, office, open space, and residential land uses); to the northwest are the Cupertino Crossroads Shopping Center and a Chevron auto service station; to the west is a commercial office; and to the south is an office EXG2014-13 10100 S De Anza Boulevard December 18, 2014 Page 2 building (currently occupied by Seagate Technology). The nearest residence to the west of the proposed sign is located 450 feet away, across S De Anza Boulevard. DISCUSSION: Application request The applicant, Tony Rago, of Rago Neon Inc., representing Armadillo Willy's is proposing to construct a new wall sign along S De Anza Boulevard, its only public street frontage. The sign will comprise of an internally illuminated body and an exposed LED barder. The City's Sign Ordinance requires signs with directly visible light sources to be reviewed and approved by the Design Review Committee with a Sign Exception application. Proposed Signage The City's Sign Ordinance does not specifically address ` � " " .���. % exposed LED signage, yet under the current ordinance �' provisions, exposed or visible neon signs shall meet ..,:4 � ' ,.�� " .:... ,. � ��: ;: �'� � � ? � , illumination restrictions specified in the ordinance. The .�a� �" � � �� `--�� • _ , � restrictions against directly visible light sources are � '"'� ,�?'•�'� �� ' � �'� ;�,�� -;� i �� i ; ;.� ��� intended to limit glare and distraction to motorists, �° � ���� � ` -���� .�� bicyclists, pedestrians, and residents in the neighborhood. � � ,; �� �.� � � . ; ��� Furthermore, permanent signs are required to meet basic u6'���������� -� -��� •�=��'°�`� � ��`�' ''� `'"� design guidelines as specified in the ordinance. " � R � „., . ..., .�. . �. ��..... .� . . . � ..�.���,��� The proposed signage is 56.35 square feet and within the limits of 1 square feet per lineal feet of building frontage on which the sign is located. The majority of the sign is internally illuminated with push- through elements. The exposed LED border is compatible with the style of the sign and serves as a decorative design element highlighting the content of the sign copy. The cumulative illumination intensity of the internally illuminated sign with exposed LED border is within the 250 foot lamberts allowed by the City's Sign Ordinance. Moreover, the exposed LED border contributes to approximately 20% of the total foot-lambert illumination. As part of the proposed project, the sign would be equipped with a manual dim control box that would be adjusted based on the light condition. The conditions of approval for the project require the following in order to minimize glare and distractions to passersby: • Restrictions on illumination intensity • A requirement that the signs be turned off by 11:00 PM or within two hours after closing (whichever is later per the ordinance) • Utilization of dimming technology to adjust brightness consistent with the restrictions on illumination intensity • Licensed lighting engineer testing and confirmation that the sign meets the illumination restrictions following installation EXC-2014-13 10100 S De Anza Boulevard December 18,2014 Page 3 Approval Findings Staff recommends that the Design Review Committee approve the project based on the following Sign Exception findings (Section 19.104.290): That the literal enforcement of the provisions of the Sign Ordinance will result in restrictions inconsistent with the spirit and intent of the ordinance; The proposed sign is consistent with the intent of the Sign Ordinance in that it minimizes glare and distraction to motorists, bicyclists, pedestrians, and neighborhood residents. The lighting intensity also has the ability to be reduced if deemed necessary by the City. That the granting of an exception will not result in a condition which is materially detrimental to the public health,safety, or welfare;and The proposed sign will not be detrimental or injurious to property or improvements in the vicinity, and will not be detrimental to the public health, safety, or welfare. The City's Traffic Engineer does not anticipate traffic safety issues with the exposed LED border. The project also includes automatic dimming technology to reduce glare and will not include animated messages. That the exception to be granted is one that will require the least modification of the prescribed design regulations and the minimum variance that will accomplish the purpose The strict application of the ordinance standards would not allow the LED technology that is currently being used in commercial signage applications. The illumination intensity and appearance of the sign addresses the intent of the City's Sign Ordinance since it would not create distractions nor impact the City's aesthetic appearance. OTHER DEPARTMENT/AGENCY REVIEW The City's Building Division and Public Works Department have reviewed the project and have no objections. No additional conditions of approval are required from the aforementioned departments. OUTREACH/NOTICING The following table is a brief summary of the noticing done for this project: N�tiee of Public FTearin 1'�c►�i�es 8��i��l�t�tic� A en�� • Site Signage • Posted on the City's official notice (10 days prior to the hearing) bulletin board (one week prior to the • Notices mailed to property owners adjacent hearing) to the project site (10 days prior to the hearing) • Posted on the City of Cupertino's Web site (one week prior to the hearing) No comments were received from any member of the public at the time of staff report production. PERMIT STREAMLINING ACT This project is subject to the Permit Streamlining Act (Government Code Section 65920 - 65964). The City has complied with the deadlines found in the Permit Streamlining Act. EXC-2014-13 10100 S De Anza Boulevard December 18,2014 Page 4 Project Received: October 17, 2014 Deemed Incomplete:November 7, 2014 Project Resubmittal:November 12, 2014 Deemed Complete:November 21 ,2014 The City has 60 days (until January 21, 2014) to make a decision on the project since this project is Categorically Exempt from CEQA. The Design Review Committee's decision on this project is final unless appealed to the City Council within 14 calendar days of the decision. CONCLUSION Staff recommends approval of the project since the conditions of approval address all concerns related to the proposed project and all of the findings for approval of the proposed project, consistent with Chapter 19.104 of the Cupertino Municipal Code,may be made. Prepared by: Ellen Yau,Planning Division Approved by: Gary Chao, Assistant Director of Community Development Attachments Draft Resolution Plan Set EXC-2014-13 CITY OF CUPERTINO 10300 Torre Avenue Cupertino, California 95014 RESOLUTION NO. 325 � OF THE DESIGN REVIEW COMMITTEE OF THE CITY OF CUPERTINO APPROVING A SIGN EXCEPTION TO ALLOW AN EXPOSED LED BORDER ON A NEW WALL SIGN LOCATED AT 10100 S DE ANZA BLVD. SECTION I: PROJECT DESCRIPTION Application No.: EXC-2014-13 Applicant: Tony Rago (Rago Neon, Inc. for Armadillo Willy's) Location: 10100 S De Anza Boulevard (APN 326-31-021) SECTION II: RECITALS: WHEREAS, the Design Review Committee of the City of Cupertino received an application for a Sign Exception as described in Section I. of this Resolution; and WHEREAS, the necessary public notices have been given as required by the Procedural Ordinance of the City of Cupertino, and the Design Review Committee has held at least one public hearing in regard to the application; and WHEREAS, the project has been determined to be categorically exempt from the California Environmental Quality Act; WHEREAS, the applicant has met the burden of proof required to support said application; and WHEREAS, the Design Review Committee finds as follows with regard to this application: SECTION III: FINDINGS 1. That the literal enforcement of the provisions of the Sign Ordinance will result in restrictions inconsistent with the spirit and intent of the ordinance.The proposed sign is consistent with the intent of the Sign Ordinance in that it minimizes glare and distraction to motorists, bicyclists, pedestrians, and neighborhood residents. The lighting intensity also has the ability to be reduced if deemed necessary by the City. 2. That the granting of an exception will not result in a condition which is materially detrimental to the public health, safety, or welfare.The proposed sign will not be detrimental or injurious to property or improvements in the vicinity, and will not be detrimental to the public health, safety, or welfare. The City's Traffic Engineer does not anticipate traffic safety issues with the exposed LED border. The project also includes automatic dimming technology to reduce glare and will not include animated messages. Resolution No.325 EXC-2014-13 December 18,2014 Page-2- 3. That the exception to be granted is one that will require the least modification of the prescribed design regulations and the minimum variance that will accomplish the purpose.The strict application of the ordinance standards would not allow the LED technology that is currently being used in commercial signage applications. The illumination intensity and appearance of the sign addresses the intent of the City's Sign Ordinance since it would not create distractions nor impact the City's aesthetic appearance. NOW, THEREFORE, BE IT RESOLVED: That after careful consideration of maps, facts, exhibits, testimony and other evidence submitted in this matter, subject to the conditions which are enumerated in this Resolution beginning on Page 2 thereof, the application for a Sign Exception, Application no. EXC-2014-13, is hereby approved; and That the subconclusions upon which the findings and conditions specified in this Resolution are based and contained in the Public Hearing record concerning Application no. EXC-2014-13 as set forth in the Minutes of Design Review Committee Meeting of December 18, 2014, and are incorporated by reference as though fully set forth herein. SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY DEVELOPMENT DEPT. 1. APPROVED EXHIBITS Approval is based on the plan set received on November 12, 2014 entitled, "Armadillo Willy's, 10100 S De Anza Blvd., Cupertino, CA 95014," drawn by Rago Neon, Inc., consisting of 10 sheets labeled 1- 10; except as may be amended by conditions in this resolution. 2. ACCURACY OF PROJECT PLANS The applicant/property owner is responsible to verify all pertinent property data including but not limited to property boundary locations, building setbacks, property size, building square footage, any relevant easements and/or construction records. Any misrepresentation of any property data may invalidate this approval and may require additional review. 3. EXCEPTION APPROVAL A Sign Exception is hereby granted to allow a new wall sign with an exposed LED border. The color of the LED border shall be white, and the background shall be black. Alternative colors may be reviewed and approved by the Director of Community Development. 4. ILLUMINATION INTENSITY AND HOURS OF ILLUMINATION The intensity of the ground sign shall not exceed 250 foot-lamberts. All illuminated signs shall be turned off by 11:00 p.m. A letter from the business operator shall be provided prior to final building permit approval acknowledging this condition of approval and incorporated in the building permit plans. 5. LED SIGN REQUIREMENTS The following requirements shall apply to the LED sign: a. The sign shall not display anunated messages, including flashing, blinking, fading, rolling, shading, dissolving, or any other effect that gives the appearance of movement. b. The sign shall not include any audio messages. Resolution No.325 EXC-2014-13 December 18,2014 Page-3- c. The sign shall utilize dimming technology to adjust the brightness of the signs relative to ambient light so that at no time shall a sign exceed a brightness level of three-tenths foot candles above ambient light, as measured using a foot candle (Lux) meter aimed directly at the sign face at a distance of 100 feet from the sign. d. An ambient light measurement shall be taken prior to final inspections using a foot candle meter at some point between the period of time between 30 minutes past sunset and 30 minutes before sunrise with the sign turned off to a black screen. e. Immediately following the ambient light measurement taken in the manner required above, an operating sign light measurement shall be taken with the sign tumed on. f. The difference between the ambient light measurement and the operating sign light measurement shall be three tenths foot candles or less. g. The sign shall comply with Section 13532 of the State of California Business and Professions Code and all other State regulations regarding LED signage. 6. LIGHTING INTENSITY ADJUSTMENT The City reserves the right to require the applicant to utilize dimming technology to adjust the lighting intensity of the sign when deemed necessary. 7. SIGN EXCEPTION REVIEW/ADDITIONAL RESTRICTIONS If complaints are received related to the intensity of the LED signage under this Sign Exception, and the complaints are not addressed immediately by the property management, then the Design Review Committee shall conduct a public hearing on the Sign Exception at which time, the approval for LED signage may be modified or revoked. T'he City reserves the right to require additional measures to reduce lighting intensity if deemed necessary. 8. SIGN PERMITS REQUIRED The applicant shall consult with the City's Building Division to obtain the necessary sign permits for this project. 9. CONSULTAT'ION WITH OTHER DEPARTMENTS The applicant is responsible to consult with other departments and/or agencies with regard to the proposed project for additional conditions and requirements. Any misrepresentation of any submitted data may invalidate an approval by the Community Development Department. 10. INDEMNIFICATION To the extent permitted by law, the applicant shall indemnify and hold harmless the City, its City Council, its officers, employees and agents (the "indemnified parties") from and against any claim, action, or proceeding brought by a third party against the indemnified parties and the applicant to attack, set aside, or void this Resolution or any perxnit or approval authorized hereby for the project, including (without limitation) reimbursing the City its actual attomeys' fees and costs incurred in defense of the litigation. The applicant and City shall use best efforts to select mutually agreeable legal counsel to defend such action, and the applicant shall pay all compensation for such legal Resolution No.325 EXC-2014-13 December 18,2014 Page-4- counsel, following the applicant's receipt of invoices from City, together with reasonable supporting documentation. Such compensation shall include reasonable compensation paid to counsel not otherwise employed as City staff and shall include City Attorney time and overhead costs and other City staff overhead costs and any costs directly related to the litigation reasonably incurred by City. If the applicant and the City cannot in good faith agree on joint counsel, the City shall have the right to retain counsel of its own choosing, separate from the applicant's litigation counsel. 11. NOTICE OF FEES, DEDICATIONS, RESERVATIONS, OR OTHER EXACTIONS The Conditions of Project Approval set forth herein may include certain fees, dedication requirements, reservation requirements, and other exactions. Pursuant to Government Code Section 66020(d) (1), these Conditions constitute written notice of a statement of the amount of such fees, and a description of the dedications, reservations, and other exactions. You are hereby further notified that the 90-day approval period in which you may protest these fees, dedications, reservations, and other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest within this 90-day period complying with all of the requirements of Section 66020, you will be legally barred from later challenging such exactions. PASSED AND ADOPTED this 18t'' day of December, 2014, at a regular Meeting of the Design Review Committee of the City of Cupertino, State of California,by the following roll call vote: AYES: COMMISSIONERS: Chair Lee, Brophy NOES: COMMISSIONERS: none ABSTAIN: COMMISSIONERS:none ABSENT: COMMISSIONERS: Takahashi ATTEST: APPROVED: /s/Gar�Chao /slWinnie Lee Gary Chao Winnie Lee, Chair Asst. Director of Community Development Design Review Committee '. * �.. ",s--�/`?" � �� ;�,���tidn Nur�ber /���,��� _,vF�,-,-_ .�,.�� :.... _., � :,:.r...,,:.� � �Y ,� ___ , / � i / / new wall 5ign � � 1 1 �� 1 I � I I I � �, I ! I / ► i � � , � � � � � � � exi5ting monument 5ign -� . e nz a v i I ; �� ,1 �- -�► , � � �� r C� � 9� � . � � n � I 3 S.Li...J�S.JR��� � � � NOV 12 2014 � i B�: i ������� 235 Laurel Ave�ue•Hayward,CA 94541 phone(51 Q)537-1903 tax(510)537-8728 This is an original,unpublished drawing, submitted in connection with a project we are planning for you.It is not to be copied, reproduced,exhibited or shown to anyone outside of your organizarion without written permiasion from Rago Neon, Inc. Project Address: Armadillo Willy's 10100 S De Anza Blvd Cupertino CA 95014 Client: Approved by: Dat�: "7HIS SIGN IS INTENDED 70 BE INSTALLED IN ACCORDANCE WITH 7HE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN." UL Certified Primary wires provided by customer. Sign voltage based upon 120v. Page 1 of 10 11/11/14(RMD) AWCup111114.pdf exi 5ti n c n iti o n 5 0 ���_,. ��"� � � � � ��' �'; r - Q :I�! � . .a__ ;,..P_....,..�..�......_._.� �.._ ....,.�...,_ .._�.. �.�_�._ .,.. .,.:_.... . „� ;� r,.._ � � «�..._,.�,._ � ., _ ���; k. f . . . . .. ...... . � � � �^ � . . .. . � -. . . .. . . -.r v�.TRw_.. ir�:�N%l sr,,.� '.'� . _ . ' . . S�.tl ��:;. ` ':���J�i���n `� � . ...r.. . .�.,..� nr�..;., y.... ,.,.f y...�.:,.. _ � ..,�y ,x . . . •{ 1 � i �f il3 �'��"�"i�1ic � �.� t. � ^ � � r . . t..��,,, : ,� � . - . :a�=w:.����n t�ti�im�: A., . _„_ _ ..� _C�:"��:ti'�1�� ,_. .� �.�- ro o5ed internal[y ilfuminated 5ign p p black ortion: u5h th roug h [etter5 p p with L�1�5tri e border L�I� border i5 p the only ex o5ed lightin� p ��Q: 5e arate element with lexan face p and vinyl gra hic5 p armadillo: 5e arate efement with lexan face p and vinyl gra hic5 p �, _._ � �: � � �-�; h. ., . �� f � s �. ,�'..'.�:..�.. �Yt -.�. . _. +. . x � �;.�C�I V ED� I . NOV 12 2014 BY: P�IC��U�1��U1 235 Laurel Ave�ue�Haywerd,CA 94541 ptwne(510)537-1903 fax(510)537-8728 This is an original,unpublished drawing, aubmitted in connection with a project we are planning for you.It is not to be copied, reproduced,exhibited or shown to anyone outside of your organizarion without written permission from Rago Neon, Inc. Project Address: �' Armadillo Willy's 10100 S De Anza Blvd Cupertino CA 95014 ._ _.� �., :�� _� � •�F� _ w. �.' - . . _ , �,����:; Client: Approved by: Date: "7HIS SIGN IS IN7ENDED TO BE INSTALLED IN ACCORDANCE WI7H 7HE REQUIREMENTS OF ARTICLE 600 OF 7HE NA710NAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. 7HIS INCLUDES PROPER GROUNDIN� AND BONDING OF THE SIGN." UL Certified Primary wires provided by customer. Sign voltage based upon 120v. Page 2 of 10 11/11/14(RMD) AWCup111114.pdf d 0 total 56.35 ft2 9� 7�� �' 113/" i nterna I I i I I u m i nated 5i n with la ered element� y � y 7 1 lexan face with vinyl gra hic5 � p 2 aluminum face with pu5h through element5 3 white LED 4 LED power 5upply 5 drain hole � provided 5ign cirucuit 7 1"tri mca p � wedge anchor5 into CMU wall 9 '/2" rigid conduit with '/4"all thread `� 51oan LEDStripe (white outline in drawing)1 " 51oan manual dimmer 5witch RECEI�TED i NOV 12 2014 BY: r L 1C � �� �� � � �x�-�,,� ;�_�; a...e_�.N:�.���. ���;��;�b;�n �Vu�ber s., ��-�,�.-,~�� . .... . _ � i rn "' l �t�, ._ , � :� � P���(���U� 235 Laurel Averwe•Hayward.CA 94541 phona(510)537-1903 iax(510)537-8728 This is an original,unpublished drawing, submitted in connection with a project we are planning for you.It is not to be copied, reproduced,exhibited or shown to anyone outside of your organizarion without written permisaion from Rago Neon, Inc. Project Address: Armadillo Willy's 10100 S De Anza Blvd Cupertino CA 95014 Client: Approved by: Date: "THIS SIGN IS INTENDED TO BE INS7ALLED IN ACCORDANCE WI7H THE REQUIREMEN7S OF ARTICLE 600 OF THE NA710NAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN." UL Certified Primary wires provided by customer. Sign voltage based upon 120v. Page3of10 11/11/14(RMD) AWCup111114.pdf � � . �'. ;:;.�,.��� �. � z� � ` � � � _ :..�`� f �# � a ��' .�.r di5tance from curb 10' max heig ht a bove 5idewa I k 8' �O" f ropo5ed change5 �'fw.e �;4 3 Fa g / .���/fi./1/f�i [ c:`:.�fi i�::;� u J¢"�i Kic„ �/(�•r � ii ( �•.� r"Yp_>�]i5>�.�;�i�i%f 1 f V4711�'�i u.++c�,.R.-. � �'y v _ ....._ . ._ ��'� �' A�:.:.,��,�,,,�,�,,. exi5ting monument current cond ition5 ��A' �:�,� ; ,�..� �..� � �-� £, , , , . . . �. �-_ _ ���r�-� ���; � .t A :..... _ ��� ;���IVEI�� r NOV 12 2014 BY: modify exi5ting monument by removing and replacing ribbon element5 �nd pla5tic face5 add 3" trim piece a-t ba5e NO change5 to 5tructure, exi5ting pole, pad, footing or electrical. . '�� � ,.,_ � � � ., P�JC��GlI��(�1 235 Laurel Avenue•Hayward,CA 9,541 phone(510)537-1903 fax(510j 537$728 This is an original,unpublished drawing, submitted in connection with a project we are planning for you.It is not to be copied, reproduced,exhibited or shown to anyone outside of your organi7ztion without written permission from Rago Neon, Inc. Project Address: Armadillo Willy's 10100 S De Anza Bivd Cupertino CA 95014 Client: Approved by: Date: "THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMEN7S OF ARTICLE 600 OF 7HE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF 7HE SIGN." UL Certified Primary wires provided by customer. Sign voltage based upon 120v. Page 4 of 10 11/11/14(RMD) AWCup111114.pdf n ew (exa n face with viny[ graphic5 new element with vinyl graphic5 ..��� , � ����j�� ._�����«��o�, c�Um��� _��.�.���r� .�a, _ j��:EI"�TE� ! NOV 12 2014 �BY:—-- -- -- -- �i�ting 4" pole xi5ting fluore5cent lamp5 efr�ove and replace 5ign face �move and replace exi5ting neon ribbon element 5hown in black ►ith LEL� powered element 5hown in red exi5ting 5ign circuit (not 5hown) ,c�xi5ting 13" x 26" x 6' concrete ba5e -�xi5ting addre55 number5 =new 3" trim piece � \�xi5ting 2" x 2' x 6'4" concrete pad ;xi5ting 18" diameter concrete footing P�DC���1��W 235 lsurel Avenue•Haywerd,CA 94541 phons(510}537-1903 tax(510)537-8728 This is an original,unpublished drawing, submitted in connection with a project we are planning for you.It is not to be copied, reproduced,exhibited or shown to anyone outside of your organization without written permission from Rago Neon, Inc. Project Address: Armadillo Wiliy's 10100 S De Anza Blvd Cupertino CA 95014 Client: Approved by: Date: Page 5 of 10 11/11/14(RMD) AWCup111114.pdf ��.a . � . � � � . . ��� __� ` � { � � � , � � � � ��� � �. . ;�! 2 � � . � ai � � � � � � � � a � � �__�_ --� � - -�� __-� —� �! -� . , - � - - i - _ -- _ % _ _-� � _ 1 � � ! v �� — -� — — — — — — — — — ; � , -- � ---J _ — — — — — — — — — — — — — — — — — — L� I� la out with a rtWOrk 5u eri m o5ed y j ��.ECEIV�� ' � � NOV 12 2014 � • BY. . _ � ;� . ,,��-��j�� . ,,i� - ,._ . .:�� > .:;��-_ ��� _��.,�.�_�_�.����' . !�.� F: �'��`��J�`;°° t�4�...y:6:.�+, ia . � ... ,., � ... Pac�o ���� 235 Laurel Avenue•Hayward,CA 94541 phone(510)537-1903 fax(510)537-8728 This is an original,unpublished drawing, submitted in connecrion with a project we are planning for you.It is not to be copied, reproduced,exhibited or shown to anyone outside of your organization without written permission from Rago Neon, Inc. Project Address: Armadillo Willy's 10100 S De Anza Blvd Cupertino CA 95014 Client: Approved by: Date: "THIS SIGN IS INTENDED TO BE INS7tiLLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF 7HE NA710NAL ELEC7RICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. 7HIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN." U L Certif ied Primary wires provided by customer. Sign voltage based upon 120v. Page 6 of 10 11/11/14(RMD) AWCup111114.pdf ��r � � �I�� ,J �� _.:. . ./G� �� _. �•?- _�._._._ . �a_ _� .,.,�.�„�.,�,....,. �� < ,a��, ;� .,... :.. ,..;,:.r � - _ i . � . - - � . � � , � � ♦ � � ♦ � � — — — — — — — — — Note: 5ign to be turned o�Ff by 11f M or wi-thin 2 hour5 after clo5ing time whichever i5 later) � — — — — - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - lnterna [ 5i n I [lumination g tota[ L�I� m o d u I e 5 79 lumen5 er L�b module 38 LM p 38 79)/56.35=53.27LM�ft2 � �� i5 only expo� �x o5ed 5i n Illumination � �:�.�. `.:���TED NOV 12 2014 tota I I i nea[ feet of L�d5tri e 14.16 p 14.2 x 52 lumen5 er foot =738.4 lumen5 p [umen5 er ft2 from L�d 5tri e 13.1 � p 53.27 + 13.1 lumen5 /ft2= �06.37 LM/ft2 = 208.�07 foot lambert5 <250 foot lambert5 ������� 236 lsurel Avenue•Hsywetd.CA 94541 phoris(510)537-1903 tax(510)537-8728 This is an original,unpublished drawing, submitted in connection with a project we are planning for you.It is not to be copied, reproduced,exhibited or shown to anyone outside of your organization without written permission from Rago Neon, Inc. Project Address: Armadillo Willy's 10100 S De Anza Blvd Cupertino CA 95014 Client: Approved by: Date: "THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELEC7RICAL CODE ANDIOR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDIN� AND BONOING OF THE SIGN." U L Certif ied Primary wires provided by customer. Sign voltage based upon 120v. Page 7 of 10 • • 11/11/14(RMD) 0o a m e r a C/ u �/ I O � � O r a j � AWCup111114.pdf • O rl t�e55 0 � O r� tn e55 0 r:�� �: ���::� � _.i �i� .,. �•,i �3���� ._��'i�> ����� �i. s�d__. �t� P�vo��ow 235 Laurel Avenue•Hayward.CA 94541 phone(51d)537-19d3 faz(510)537-8728 This is an original,unpublished drawing, submitted in connection with a project we are planning for you.It is not to be copied, rtproduced,exhibited or shown to anyone outcide of your oiganization without writttn permission from Rago Neon, Inc. Project Address: Armadillo Wiliy's 10100 S De Anza Bivd Cupertino CA 95014 Client: Approved by: Date: "THIS SIGN IS INTENDED t0 BE INS7ALLED tH ACCOROANCE WRH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAI.ELECTRlCAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THiS INCLUOES PROPER GROUNDING AND BONDtNG OF THE SIGN." UL Certified Primary wires provided by customer. Sign voltage based upon 120v. �4' IOCin��a� -h;, ders in LED Technolog� • • � lmmin o utlons Tu�n-Key Dimming fo� SloanLED 12 VDC Systems Specs and Features... • Can operate off primary voltage of 100-240 Volt AC • Uses SloanLED's Modular 6012 Volt DC power supply � Maintains power supply's footage capacities(see Power Supply Footage chart) • Manual solution uses SloanLED's proprietary dim control box and can run up to 15 power supplies • Automatic solution uses a Control Station and an Electronic Fluorescent Dimmer (EFD)from Marlin Controls,and can run up to 24 power supplies �� * �; x.'r ,�'4±i' �uti �. �'� Fully Compatible with all S1oanLED 12 VDC Products Maintains LED Life Span and Warranties Manual or Automatic Configurations Easy to Install and Operate These user friendly dimming solutions combine SloanLED's lighting systems and power supplies with dimming modules and either a manual dim control box, or an automatic control station. • Both solutions place an Osram Optotronic OT Dimming Module between each power supply and its run of LED products (available from SloanLED) • Maintains benefits of LED systems' Constant Current Technology Manual System e 4�18 Dim Control Box (White) � 701843 (Switch Plate and Knob not induded) e 701507-MOD 400311 (Gray) SloanLEO 120.240 VAC 100.240VACT012VDC (I� POWER SUPPLY t2 voC (OUTPLn 701817 LED PRODUCT •�, .. �� OPTRONIC OT DIFIMING MODULE • Does not affect the LEDs'life,nor impact their warranties • Easy-to-follow installation guides available for both solutions Automatic System MARLIN CONTROL STATION* I �COND,2 TYAST R,BELDON 9402 � iz�x SbaN_ED\ 400418 � 100-240VAC TO 12V (Whik) POWERSUPPLV OPTOTRONIC OT DRAMMG MODULE I VUI .711 II�IC�VUII.0 IVI LLV il II IVVQIIVI 1�LR',JCI ICI II.0 tX.JCICI.IIVI l—"'.J11 I�.0 I 7J! 5725 Olivas Park Dr.�Ventura,CA 93003�Toll-Free 888J47.4LED•805.676.3200•Fax 805.676.3206 •www.SloanL_ED.com•info@SloanlED.co,��. !���'�=i_.•.�i�tir��.:�:..� ' R � NOV 12 2014 � I ' , 11/11/2014 Convert foot-�2mbert[fLj<—>ItmeNmeter�/steradan•PhOtomeVy—Light•Luminanr,P•C'omp��ct�r__.._ _--� &` � – °---�- �'q"'�,'i����!''�5����.C41'il ��� _ u�h�r�Irngur:t:and thcir�lirnt;mrtt ..���,� Common Mechanlcs Meat FluidS SourW I.iqht EkGttieal . •�tam Radiat�on Mnc Convert foot-lambert[fL]<—>lumen/meter2/steradian Online Unit Converters•Photometry—Light•Luminance•Help �„ Select a converter. Convercer View Luminance � <<?��'>» ��=+IC�.:iitor pr FuII Table CakulatU? mn..,.. k�,�. From: To: �66.37 208.5075044188 66.37 lume�/foot'/steradia� = 208.5075044188 foot-lambert candeW/meter=[cd/m=] candela/meter�(cd/m�) candela/centimeter�(cd/cm=] candela/cenGme[er�(cd/cm=] candela/foot�(cd/R�] candeia/foot=(cd/k7) candelaJ�nch7[cd/�n�] candela/inchl[cd/i�:] kibcandela/meter=(kcd/m�J kilocandela/meter2 jkcd/m�j sUlb[sbj sUlb[Sb] lumen/merer2/steraaian Iumen/meter�/steradian lumen/cen[imeter�/steradian tumen/cennme[er=/sterad�an lumen/footx/stered ian tumen/foot2/ste radia n nit(nt) nit[ntj mdhmt[mny mdhrnt[mntJ lambert[Lj lambert(lj mdlilambert(mL] m�lhlambert[mL] foot•lambert[fl] foat-lambert�ttj apostilb[asb] apos0lb(asb) blondel blondel bril brd skot sko[ A lume�per square foot per steradian(Im/ft=�s�)is a A fooMambat(fL,it or ft-L)is a unit of luminance in U.S. un�t ol iummance in the US Customary Un�[s and Bnbsh customary u�its and other unft systems.A foot-�ambert Impenal Uni[s.1 cd/ft2=1 Im/ft=•sr equals 1/n candela per square toot,or 3.426 candelas per square meter.!t Is rareFy used by etecVical and iighting eng�neers,who prefer the candela per square foot or candela per square meter.However,it is ofte�used in the unema �ndustry for measunng the lum�nance of images on a projection screen and in the flight simulatlon indusdy for measur�ng tAe bnghtness oi visual display systems of flight s�mulators. 1 foot-lambert[fL)=3.4262590996323 lumen/meterz/sieradian More about Luminancr� Thc sky�n this�mage of The M�ss�on Dstntt�n Scn�•�-+�c,s����s a�rr t�quiluminant r�r.ysici,_�. Contras!_ . . :uminarrce..,� ..-�!_._. Vlsual Ef`c�+�� Oes�g� http:/lwww.translatorscafe.com/cafe/EN/units-cornerterA um i narx�.e�147/fooi-I�n bert-Iixnen9�2Fmeler°/aC 2%B2%2Fsteradian/ Definitions r���rni��� 235 Leurel Avenue•Hayward,CA 9,541 phone(510)53T-1903 tax(510)537-8728 This is an original,unpublished drawing, submitted in connection with a project we are planning for you.It is not to be copied, reproduced,exhibited or shown to anyone outside of your organizarion without written permission from Rago Neon, Inc. Project Address: Armadillo Willy's 10100 S De Anza Blvd _ Cupertino CA 95014 Photometry—Llqht Photom�ery is the suenc measurement of energy c I�qhi,�n term5 Of its perce the human eye. Unlfke ra0iometry,w��th =- '�•�' measurement of absolute ene�gy(indud�n9 i�qht),�� radlant povaer at each wa we�ghted by a lum�nos�ty ,^°.., _ _ sensitivity function ttiat m d,,,�:�,�;;��:;,;�� briqhtness sensitivdy. Luminance luminanoe is a measure by a light source in a givc area per unit solid anqle. luminance is the nmount through or is emitteC tror within a 9rven solid angle The 51 urnt for luminance square meter(cdlm�).A luminance�s the nit.The is[he stllb,which is equz square centimeter or 10� Unrt defirniwns Usiny the Lumina�ce C Th�s online urnt converter accurate convenion betw measure,from one syste Conversion page proviCe� engfncers,translators,ar acLv�t�es reqw�e wak�ry measUrea�n d:'temnr,.�� You can usc th�s onllne cc behveen se�e�al hund�ed metric,British and Ameri� or severai thousand pa�rs accekratlon,arca,elerni leng[h,light,mass,mass volume,power,prcssure, Gme,torque,vebc�ty,vn capacity,volume flow,an Note:Integers inumDers per�od or exponent rrotat� accurate up to IS Agict a number of d�g�ts aRer tne In this calculator,E notat� reDresent numDers that a large.E notstion rs an a the suentific nota0on a 1,103,000=1.303�1Q� (from exporxnt)rcprcse� `trmes ten raseo to me t� ua Client: s ��� °�:`�y�-�_°�' ,„_,.:,...2�3-,,, . :•'sia.;:.ls-i�:!t"; .. ��,�'��_.'��� _;i;: r.� � Approved by: Date: "7HIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH 7HE REQUIREMEYTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE ANDIOR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF 7HE SIGN." U L Certif ied Primary wires provided by customer. Sign voltage based upon 120v. Page 9 of 10 11/11/14(RMD) AWCup111114.pdf ���� Sloa n L E D �V'� I_eaders in LED Technology � �� �r4. Mounting Buttons 701156 400775 <� 0 � LEDStripe Large-profile LED tubing For over fifteen years LEDStripe has added lighting elegance and distinction to buildings worldwide.This patented LED-based rigid tubing system,with its large profile and long runs, has become the border tube system of choice for many retail,restaurant,and lodging chains. • Daytime color when non-illuminated • High impact acrylic:UV stable,hydrocarbon insensitive,and non-fading • Can be factory bent to minimum 12 inch radius • Can be cut in the field • Conforms to UL 48 requirements Joint&Corner Covers Specifications r� J� � Dimensions �V 701361-X 701362-X 701363-X 701364-X Bends Radial bend .- � �, �/ .% Factory bends In-field bends Operating temperature Protection class Brightness(LM/ft) Power per foot Power capacity COIOfS Mounting Accessories Width 1.00 in Height 1.68 in Lengths 1 ft,2 ft,4 ft,6 ft,8 ft,10 ft 12 in radius(radia)and flat bend) Radial bend 14 ft Flat bend 19 ft -40°C to+70°C IP66 52 lumens per foot(value provided by Sophia Wagner at Sloan LED 1(888)747-4533 x 122 1.5 W(except 1-foot piece at 3.0 W on average) 60 ft per SloanLED 100 W 24 VDC power supply Red,Orange,Amber,Green,Blue,White(6500 K),Lemon Yellow Round pre-mounting buttons 701156 Slide and mount rectangle mounting buttons 400775 Snap-on,colored joint and corner covers for clean finish: Joint 701361-X Outside Corner 701362-X Inside Corner 701363-X Step Corner 701364-X �-�.��_'.,�;�'(�,-m��-.�.� �_;; ;i: ;�:. `_. 1�- �����f i�',����- . ,��?�'��'���E� � � � ' {�in�i � � �n�a ' �, . � _. � � 11/10/2014 5050LED modules HM-2S-Fanver.com Home Profilc• News Service ContactUs fB1�'�'� - fi��i�i� I'roducu Llill Module L,ED Power Sun�lv UUCULConstant Volatec 1 f'.I) POK'CiSllDDIV 5050LED modules HM-2S UU CUL Constant Curccnt LED Po��cr � :� .�.--. � .�_, � uz. ....�d., .,.M�.a CF.Constant Voltaee LED Power $UDDIV LED Modulc LED Lightin� Y ��" MODEL 5050LED modules HM-2S Model: HM-25 LED type: 5050 SMD Chip brend: ES Size mm: 44*16*6.5 mm IP grade: 65 Amp: 60mA View An91e: 120 Color Temperature: 4500�10000k Parameter Lifetime: 30 000 hours Voltage: 12v Power W: 0.5w LED Quantity: 2 Color: White,Red,Green,Yellow,Blue option. Lumens: 38LM Packing: 200pcs/box 2000pcs/Carton Carton Packing Size: 540*455*325 mm(L*W*H) http://www.fanver.comfi ndex.php/productsAec�m odul e/ul-cul-lec�m odul�tem/5rhm-2s.htm I 1/2 � + �__--� Pac�o��o� 235 Laurel Avenue•Hayward,CA 94541 phone(510)537-1903 fax(510)537-8728 This is an original,unpublished drawing, submitted in connection with a project we are planning for you.It is not to be copied, r e p r o d u c e d,e x h i b i t e d o r s h o w n t o a n y o n e outside of your organi7adon without written permission from Rago Neon, Inc. Project Address: Armadillo Willy's 10100 S De Anza Blvd Cupertino CA 95014 Client: Approved by: Date: "THIS SIGN IS IN7ENDED TO BE INSTALLED IN ACCORDANCE WITH 7HE REQUIREM�I�TS OF AR7ICLE 600 OF THE NA710NAL ELEC7RICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. 7HIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN." U L Certif ied Primary wires provided by customer. Sign voltage based upon 120v. Page 10 of 10 11/11/14(RMD) AWCup111114.pdf