13010132 - SI � RECEI�TEI�
� TESTING ENGINEERS, INC.
� JUN 1 �� 2013
2811 Teagarden St. 510-835-3142 510-834-3777fax
San Leandro,CA 94577 800-660-3142 Name:
San Leandro • San Jose • Martinez
INSPECTION REPORT Week Ending: 5/24/13
PROJECT#57260 TYPE OF INSPECT'ION:
Visual Welding
PROJECT: PLACE OF INSPECTION:
TA07B South:AOS Relocation Glazier Iron Works(shop)
10100 N.Tanfiau Avenue
Cupertino,CA
Permit#1301-0132 .
DATE 5/22/13
HOURS 4
INSPECTOR J.Yoka
Reported to Brian Rose of Glazier Iron Works at the shop as requested.
Checked welder qualification papers(Carlos Cervantes,ID#6978). Checked WPSs and verified welding parameters.
Verified proper elecirode storage. Verified proper preheat. Visually inspected joint preparation and fit up. Performed
continuous visual inspection of the in progress welding performed by one qualified welder using the FCAW process with
E71T-8 wire electrode.
Weldments consist of 1/a"complete joint penetration groove welds,partial joint peneiration groove welds and single pass fillet
welds jouung channel stringers to channel siringers,connection plates,bent checkered plate threads,plate and pipe posts;
and pipe posts to pipe rails for ladder assemblies shop marked A21 and A24(complete).
The preceding work was,to the best of my knowledge,in compliance with engineer approved plans and specificaiions,
including revisions by engineer and shop dxawings D21 and D24,dated 5/15/13.
�
Reviewed by:
David Chippero
Special Inspechion Division Manager
1cc: Apple Computer Inc./A.Vu
Hayes Group/S.Lee
SW Structural,Inc./S.Wade
XL Construction/J.Seacrist
City of Cupertino/Bldg.Inspeciion Dept.
This report can be reproduced only in its entirety unless written permission from TEI is obtained.
Page 1 of 1
_
� TESTING ENGINEERS, INC.
2811 Teagarden St. 510-835-3142 �c�1 � .�1�834-3777 fax
San Leandro,CA 94577 800-660-3142
JUN 0 5 2013
San Leandro • San Jose • Marlinez
INSPECTION REPOR� Week Ending: 4/26/13
ame�
PROJECT#57260 TYPE OF INSPECTION:
Visual Welding
PROJECT: PLACE OF INSPECTION:
TA07B South:AOS Relocation Jobsite
10100 N.Tantau Avenue
Cupertino,CA
Permit#1301-0132
DATE 4/23/13
HOURS 4
INSPECTOR A.Gundersen
Reported to Chris Martin of Sttmmit Welding at the jobsite as requested.
Performed periodic visual inspection of welding previously completed without special inspection.
Weldments consist of 5/16' single pass fillet welds on both sides of outrigger;and 5/16"fillet welds on 3-12" on center for
angles.
NOTE: Request for information: The following items are not in compliance with the approved job plans and
specifications. These items need to either be corrected or a�proved in writing by the responsible en 'g�neer
before the work can be accepted and a final report can be issued.
> Detail provided did not indicate weld size,pattern or length,and did not include weld symbols.
The preceding work,as noted,was to the best of my knowledge,in compliance with approved plans and specifications,
including revisions by engineer,and Drawing A7.2,dated 1/25/13.
�_ � -�.,,,.--�--�-�".�\
Reviewed by: �
David Chippero
Special Inspection Division Manager
1cc: Apple Computer Inc./ A.Vu
Hayes Group/S.Lee
SW Structural,Inc./S.Wade
XL Construction/ H.Seacrist
City of Cupertino/Bldg.Inspection Dept.
This report can be reproduced only in its entirety unless written pern►ission from TEI is obtained.
Page 1 of 1