Loading...
TUP-2013-04b CITY OF CUPERTINO 10300 Torre Avenue, Cupertino, California 95014 (408) 777-3308 To: Mayor and City Council members Chairman and Planning Commissioners From: Aarti Shrivastava, Director of Community Development� � Prepared by: Stephen Rose, Associate Planner ��— Date: September 16, 2013 Subject: Director's Temporary Use Permit, TUP-2013-04 to allow an AT&T COW (cell on wheels) facility for a period of one year at 19050 Pruneridge Avenue (Apple); APN: 316-06-033, to allow time to identify and permit another permanent cell site. Chapter 19.12.030 of the Cupertino Municipal Code allows for administrative approval of a temporary use permit, authorizing the use of a site in any zoning district for a temporary use. The Director reports his/her decision to the City Council & Planning Commission in time to allow an appeal of the decision within fourteen calendar days. DISCUSSION The applicant, jason Osborne (Osborne & Associates, LLC), on behalf of AT&T, is requesting approval to allow the installation of a temporary unmanned wireless cell facility, COW (cell on wheels), for a period of one year in the parking lot of the subject Apple owned property. The temporary facility is needed as Apple will be demolishing (as part of the Apple Campus 2 project) the building upon which the existing cell tower is located. The proposed facility will prevent any interruption in cellular service while AT&T works on identifying and permitting a new permanent cell site. Location The subject property is an existing office building occupied by Apple, bounded by Pruneridge Avenue to the north, N. Tantau to the east, and other Apple office buildings to the south and west. TUP-2013-04 19050 Pruneridge Avenue Temporary COW Page 2 �-'� � r---,'"r,,,� �y� .._,.—__ _— }�.2 v�'•. � _._'.. "'._ iPa'EFil NE r�l.\ k't�� Y};i �:`, �_ ___�__! . i —_,,� �1� y �?SiIE 4:/S.l:—.,,,� f.r%�r""J ,._� _ _ . . . ' . . �I� � . _ � 1G j�~ �� .. i I i i i � , I i � ..._ 9 � e r . i �. i S ; i 1 � ` :�_ . ' - i i ..... � —,.—,�'__�� ..._ I � I ; �.�,.... , , .. ,.:. _. � I I - c�r....°'mwr.�w.��t.-� .w �, _ r I � � 1 � ______---""`V".'.\� __W r � � I�V , ._ _____--- �,} �—����� 'I '� � (� ,�;��-� �' y 1 4 Sc iG.1E i 1 ....� �..... . I �.. �.. I .... t I �.-I?:9°XUl P+N:IY:�lvi./ ....... i � .. 'E`,.:Rlfii .. . I Y i S TFBI:)W�:eCs tTi6�1 PvV(k-,, I J.':,. � � � � � l .��ii .�._v'J_"2� . I I 'h � � R'i y t .. i ' _as�.- ... � i � � - � � ( � _I _ , -�-- , , , � _ , � � , ....... 1..... ' EE ai?E L r' � �i . ;.x°as�-e• , i i ,. .ixt l['#xEa wi � � ....... . � . , � i E T .�:qltk IFF FFM"S � �� . . { , t � � � � � 1 tF`^YLLLa1k ti ATtI ",nFR?.6.(.—� � 1 ` f � t[raiva r,n s.ia:o re.c�..� � �.y.1 � f� vu.:�r+w�i�r- `..,,/ .: , �•, - s m�at..s:cs.;°tu -;E s�'riu:xua.ta� _m�vm..,F uar s/p}nt:r r �:e x/�.ie:x 1�.at ? � _ - ,.�_�n+i!CVNS k f48'�FAf �/� I ` _. { i i-- -— � — � � — � -- ,� ~ � � —<;—e—t, �...... . �r�,u� ce u�. f � �l F{ , \ .ti ,.-,»..:� � iEi'-"�3T#ICT:a J �., I z�a,c¢,;�rtµ / j.. 4 r C6 A�NLLf?lx'KI�L'�T! � b 1 I { � � j � . ,.. .. ... � !-tF):WS1k:CRan 9R.' � (' � � �".iW.:l�'L � � 4 ��ITE f;.,L:�.ti " ,w-s� ti.;TIi;E � vwx��s��vrzw r.:a r��e.�nE er rw:a�on�m.artaw�*e Evui¢�:i�:�a iMC.M;N51 KS?il�itlE PoR ME E�fLWi11:T:t itE?'e�>:.�;f.M!'J'i M31EJe�.kASi The temporary COW is proposed at the southwest corner of the project site. Equipment The proposed equipment includes a new temporary unmanned mobile telecommunication facility consisting of a new AT&T equipment/battery cabinet, two new masts supported by coaxial cable, 6 antennas, 3 new RRU's, and a GPS antenna. Overall the facility will be 55' tall, 30' long and 18' wide once setup. TUP-2013-04 19050 Pruneridge Avenue Temporary COW Page 3 -:x;=rtrcvu<..;;a x r��.�«; �'l�,cKw<.v«��nM1�;��xc=�: i fi K AiST Rl1EItA➢�. �� �i ldW`:�1<.IS.�PY F.;I.W[ii ...... ..... ... ....... . .................................. .. ..SS :.L � . �4,„iRi 4v1Eti F TY_f E r. T. �,F k tA1CIH�YP�i ... \_._..._.. __.____ / —� 3S9'-'t'h�L - � . {. �+;'�'1ER'F'4'�FTbT N:iE`�'��i . #. ♦ t_�I'-'i'{G.L. -.`.i A�:TE4'1A u�S1,T'M1'�F 2 �// 'i'; N1:�t. ..,. I �14�:i::;Y fi7'�'2.TY'f�!! N�'::RTE�P' �4A.,Tj-. ��1:1�I'i 44'lE`R.F.- .��:� �'. S � ,� �,. (\i�il.'_-S r�;i. �.�\ \ / ;N;iEY��;d!`*Y i:.^iti.;ifLL JR \\.� W1EEL��t!!�T wi fN?47kT � �` d�TEYYf<,k EiJ1'kERT�-,.,\ �: : �� (E P "t,ryU��FK �V.�:-^.�'CD�::AE SWr:L AL'GS G�IE FEK"_E k��1.33:11ESH-,.. � %' �1�!� .•.�XFI':Llhl:FE�r.E �� / ;i � �� t ��� �-�..�n LEvEL �... Y ..2__�..3-.�-- �w T�i.�. ���� __ ; p-r; Elevation View ViSIbZlZt1� The COW is proposed to be located towards the rear of the existing Apple office building, interior to the project site. While proposed at 60' tall, the COW will be obstructed from view from the north, west, and east by trees, and another Apple office building to the south. Noise No significant noise impacts are anticipated, provided that the equipment does not generate noticeable noise or vibration and the closest residential use is located approximately 800+feet away from the proposed equipment. Duration The facility is proposed for a period of one year while AT&T works on identifying and permitting a new permanent cell site. TUP-2013-04 19050 Pruneridge Avenue Temporary COW Page 4 FINDINGS Prior to approval, the Community Development Director must make the following findings as outlined in Section 19.160.030 of the City of Cupertino Municipal Code. Staff analysis is shown below the required findings in italics. A. The granting of the application will not be detrimental or Tnjurious to�roperty or improvements in the vicinity, and will not be detrimental to tl2e pi�blic, health, safety, general welfare, or convenience; and As proposed, the temporary COW shall provide adequate protective barriers. The plans will be required to be submitted as part of a building permit for review for consistency with applicable code and safety requirements. The temporary COW is proposed to mitigate any loss of cellular service in the area while AT&T attempts to find a new permanent facility. Due to the temporary nature of the use, no significant impact to public convenience is anticipated. B. The pro�osed use will be located and conducted in a manner in accord with the Cupertino General Plan and the purposes of this title. As conditioned, the project shall be conducted in a manner that serves the General Plan Guiding Principals in that adequate safety measures have been taken to mitigate potential impacts to people, property, and the environment. The proposed location promotes attractive community design in that the facility is temporary and not highly visible. The facility has also been reviewed for consistently with the setback requirements stipulated in the City of Cupertino Wireless Facilities Master Plan. The facility meets the required setbacks being greater than 75 feet to any residential property (closest is approximately 800+feet to the east). ACTION The Director of Community Development deems this application as minor, and approves the temporary COW subject to the following conditions of approval. 1. APPROVED PROTECT This approval is based on the plan set entitled "APPLE WORLD CAMPUS COW" consisting of eight (8) sheets (T-1, A-1 through A-6, and E1), stamped as TUP-2013-04 19050 Pruneridge Avenue Temporary COW Page 5 received August 27, 2013, except as may be amended by the following conditions. 2. ACCURACY OF PROTECT PLANS The applicant/property owner is responsible to verify all pertinent property data including, but not limited to, property boundary locations, building setbacks, property size, building square footage, any relevant easements and/or construction records. Any misrepresentation of any project data may invalidate this approval and require additional review. 3. DURATION The temporary COW and all associated equipment shall be removed from the site no later than September 12, 2014. A new Temporary Use Permit shall be submitted to the City for review and approval prior to the Temporary Use Permit expiration. 4. BUILDING PERMIT REQUIRED Issuance of a building permit shall be required prior to installation of proposed equipment and facilities. 5. GRADING AND CONSTRUCTION HOURS All grading activities shall be limited to the dry season (April 15 to October 15). Grading hours shall be limited to Monday through Friday, 7 a.m. to 8 p.m. Grading, street construction, demolition or underground utility work shall not occur on Saturdays, Sundays and holidays, and during the nighttime period as defined in Section 10.48.053(b) of the Municipal Code. Construction activities shall be limited to Monday through Friday, 7 a.m. to 8 p.m. and Saturday and Sunday, 9 a.m. to 6 p.m. Construction activities are not allowed on holidays. The developer shall be responsible for educating all contractors and subcontractors of said construction restrictions. Rules and regulation pertaining to all construction activities and limitations identified in this permit, along with the name and telephone number of a developer appointed disturbance coordinator, shall be posted in a prominent location at the entrance to the job site. 6. ANNOTATION OF THE CONDITIONS OF APPROVAL The conditions set forth shall be attached to, incorporated into, or annotated on the first page of the building plans. 7. NOISE Noise shall not exceed the maximum Daytime and Nighttime exposure limits TUP-2013-04 19050 Pruneridge Avenue Temporary COW Page 6 prescribed in Chapter 10.48 of the City of Cupertino Municipal Code. 8. CONSULATION WITH OTHER DEPARMENTS The applicant is responsible to consult with other departments and/or agencies with regard to the proposed project for additional conditions and requirements. Any misrepresentation of any submitted data may invalidate an approval by the Community Development Department. 9. NOTICE OF FEES, DEDICATIONS, RESERVATIONS OR OTHER EXACTIONS The Conditions of Project Approval set forth herein may include certain fees, dedication requirements, reservation requirements, and other exactions. Pursuant to Government Code Section 66020(d) (1), these Conditions constitute written notice of a statement of the amount of such fees, and a description of the dedications, reservations, and other exactions. You are hereby further notified that the 90-day approval period in wllich you may protest these fees, dedications, reservations, and other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest within this 90-day period complying with all of the requirements of Section 66020, you will be legally barred from later challenging such exactions. 10. INDEMNIFICATION To the extent permitted by law, the Applicant shall indemnify and hold harmless the City, its City Council, its officers, employees and agents (the "indemnified parties") from and against any claim, action, or proceeding brought by a third party against the indemnified parties and the applicant to attack, set aside, or void this ordinance or any permit or approval authorized hereby for the project, including (without limitation) reimbursing the City its actual attorneys' fees and costs incurred in defense of the litigation. The City may, in its sole discretion, elect to defend any such action with attorneys of its choice. This approval is granted on September 16, 2013. Please note that an appeal of this decision can be made within 14 calendar days from the approval date. The fourteen calendar day appeal period expires on September 30, 2013. If an appeal is filed, a public hearing will be scheduled before the Planning Commission. If no appeal is filed, the Director's Temporary Use Permit becomes effective on October 1, 2013. Attachments Attachment 1 - Plan Set G:\PlamTing\PDREPORT\TUPreports\2013\TUP-2013-04.docx ,,,H ,-,��� ,A��.,. s;Y '��� f�f��N �i � ,. �-, ���. F/�h.. �, �,� r;,. ,r�� APPLE WORLD CAIVIPUS COW PROJECT DESCRIPTION A(N) TEMPORARY UNMANNED MOBILE TELECOMMUNICATION FACILITY KNOWN AS A COW, "CELL ON WHEELS", CONSISTING OF(1) (N)23"RACK W/(1)(N) 6601-DUL RBS UNIT, (3) (N) RRUS-11'S MOUNTED TO(N) MAST, A (N)LINEAGE DC POWER PLANT, A(N) BATTERY RACK, (6) (N) ANTENNAS, (24) (N) RUNS OF COAX CABLE, &A(N) GPS ANTENNA WITHIN A(N)30'X30' LEASE AREA. SI?E NAME: COUNTY: APN: SITE ADDRESS: CURRENT ZONING: CONSTRUCTION TYPE: OCCUPANCY TYPE: PROPERTY OWNER: APPUCANT: LEASING CONTACT: ZONING CONTACT: CONSTRUCTION CONTACT LATITUDE: LONGITUDE: AMSL: PROJECT INFORMATION AP?LE WORLD CAMPUS COW SANTA CLARA 316-06-033 19050 PRUNERIDGE AVENUE CUPERTINO, CA 95014 V-B U, (UNMANNED COMMUNICATIONS FACILITY) AT&T 4430 ROSEWOOD DR BLDG 3, 6TH FLOOR PLEASANTON, CA 94588 ATTN: JASON OSBORNE (415) 559-2121 ATTN: JASON OSBORNE (415) 559-2121 ATTN: MARK CONWAY (510) 206-1463 N 37'19' S2.8" NAD 83 W-122'00' 27.3" NAD 83 f 162' SITE #: CCU2693 /CCL02593 JURISDICTION: CITY OF CUPERTINO POWER: PG&E TELEPHONE: AT&T VICINITY MAP DRIVI NG DI RECT��NS FROM: 4430 ROSEWOOD DR BLDG 3, 6TH FLOOR, PLEASANTON, CE�94588 T0: 19050 PRUNERIDGE AVENUE, CUPERTINO, CA 1. HEAD EAST ON ROSEWOOD DR 20 FT 2. MAKE A U-TURN 0.5 MI 3. TURN RIGHT ONTO OWENS DR 0.2 MI 4. TURN RIGHT ONTO HACIENDA DR 0.3 MI 5. SLIGHT RIGHT TO MERGE ONTO I-580 W TOWARD OAKLAND 1.8 MI 6. TAKE THE EXIT TOWARD SAN JOSE 0.8 MI 7. MERGE ONTO I-680 S 16.6 MI 8. TAKE THE MISSION BLVD/STATE ROUTE 262 EXIT TOWARD I-88C; 0.2 MI 9. KEEP RIGHT AT THE FORK, FOLLW SIGNS FOR MISSION BLVD W F,ND MERGE ONTO STATE ROUTE 262 EXIT TOWARD I-880 0.9 MI 10. KEEP LEFT AT THE FORK, FOLLOW SIGNS FOR INTERSTATE 880 S/SAN JOSE AND MERGE ONTO I-880 S 12.6 MI 11. TAKE THE EXIT ONTO I-280 N TOWARD SAN FRANCISCO 4.3 MI 12. TAKE THE WOLFE ROAD EXIT 0.4 MI 13. TURN RIGHT ONTO N WOLFE RD 0.1 MI 14. TAKE THE 1ST RIGHT ONTO PRUNERIDGE AVE 0.4 MI END AT: 19050 PRUNERIDGE AVENUE, CUPERTINO, CA ESTIMATED TIME: 42 MINUTES ESTIMATED DISTANCE: 39.1 MILES .+�"°.��i,3��4� . ', , . - .�t-�� ,.� - , . .,t , .,.. ... .. . > .y_ . . . .,,. ,, " . _ CODE COMPLIANCE ALL WORK & MATERIALS SHALL BE PERFORMED &INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: t. 2010 CALIFORNIA ADMINISTRATIVE CODE (INCL TITLES 24 & 25) 2. 2010 CALIFORNIA BUILDING CODE 3. 2010 CALIFORNIA ELECTRICAL CODE 4. 2010 CALIFORNIA MECHANICAL CODE � 5. 2010 CALIFORNIA PLUMBING CODE D JGL' � LJ U �j 6. 2010 CALIFORNIA FIRE CODE 7. LOCAL BUILDING CODES ^"�1 ,G ( 20�� 8. CITY/COUNTY ORDINANCES 9. ANSI/EIA-TIA-222-G � ALONG WITH ANY OTHER APPLICABLE LOCAL&STATE LAWS AND REGULATIONS DISAB�ED ACCESS REQUIREMENTS THIS FACILITY IS UNMANNED &NOT FOR HUMAN HABITATION. DISABLED ACCESS& REQUIREMENTS ARE NOT REQUIRED IN ACCORDANCE WITH CALIFORNIA STATE BUILDING CODE TITLE 24 PART 2, SECTION 11346.2.1, EXCEPTION 4 SHEET T-1 A-1 �-2 A-3 A-4 A-5 A-6 E-1 SHEET INDEX DESCRIPTION TITLE SHEET SITE PLAN tNLAR�tG SiTt PLHiv ELEVATIONS DETAILS DETAIL DETAILS ELECTRICAL PLAN APPROVAL RF LEASING ZONING CONSTRUCTION AT&T APPLE WORLD CAMPUS COW CCU2693/CCL02693 190�0 PRUNERIDC;E AVE CUPERTINO.CA 9i014 ISSUE STATUS Q DATE DESCRIPTION BY 08 12 13 CD 90� A.G. DRAWN BY: A. GOLESORKHI CHECKED BY: C. MATHISEN APPROVED BY: - DATE: 08/12/13 wo� � n v "��" :• rn o o' o;¢ -,�:. U o c�0 °�oy� . ��� � m�,� - �a�r � �o �w' �-�� C� x p � ��' � � E =z ei.1 w L ° _°� :: a ° �ow "_ �� c c I a � �' � �; � wo>� ��� I V`"� m o � �0°8 0.1'i cn �gN � � �' ��ms Cr. • � �>� = - � ^ U�> �,;�� �r. �� m� uY, � �'�i• '� � � ° _ �.... � - y�� � v U� ao t'r'� � a w � �, w�� w��w � > � � � � x � � � � J�m �� O V �z O ,`���`°'�� O Q 3� ?�y. �N ;;�,� �,°,u� � -�,� �a ,- �,",.� �,� SHEET TITLE: TI T�E SHEET NUMBER: T-1 PROJECT GENERA� NOTES t. THIS FACILITY IS AN UNOCCUPIED WIRELESS TELECOMMUNICATION FACI LI TY. 2. PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY, UNLESS NOTED OTHERWISE. 3. THE SCOPE OF WORK SHALL INCLUDE FURNISHWG MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE ORAWINGS. 4. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS, AND CONFIRM THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER AND ENGINEER PRIOR TO PROCEEDING WITH THE WORK. 5. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PAY FOR PERMIT FEES, AND TO OBTAIN SAID PERMITS AND TO COORDINATE INSPECTIONS. 6. THE CONTRACTOR SHALL RECEIVE, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. 7. CALL BEFORE YOU DIG. CONTRACTOR IS REQUIRED TO CALL 811 (NATIONWIDE "CALL BEFORE YOU DIG" HOTLINE) AT LEAST 72 HOURS BEFORE DIGGING. 8. ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. 9. THE GENERAL CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING THE BEST SKILLS AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. CONTRACTOR SHALL ALSO COORDINATE ALL PORTIONS OF THE WORK UNDER THE CONTRACT; INCLUDING CONTACT AND COORDINATION WITH THE CONSTRUCTION MANAGER AND WITH THE LANDLORD'S AUTHORIZED REPRESENTATIVE. 10. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, PAVING, CURBS, GALVANIZED SURFACES, ETC., AND UPON COMPLETION OF WORK, REPAIR ANY DAMAGE THAT OCCURRED DURING CONSTRUCTION TC TNE SATISFACTION OF THE PROJECT MANAGER. 11. KEEP GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS AND RUBBISH. REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY. LEAVE PREMISES IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. 12. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED, OR OTHERWISE DISCONNECTED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, AS DIRECTED BY THE RESPONSIBLE ENGINEER, AND SUBJECT TO THE APPROVAL OF THE OWNER AND/OR LOCAL UTILITIES. 13. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND ALL OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK SHALL BE PROTECTED AT ALL TIMES. 14. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. 15. THE CONTRACTOR SHALL PROVIDE A TOILET FACILITY DURING ALL PHASES OF CONSTRUCTION. 16. SUFFICIENT MONUMENTATION WAS NOT RECOVERED TO ESTABLISH THE POSITION OF THE BOUNDARY LINES SHOWN HEREON. THE BOUNDARY REPRESENTED ON THIS MAP IS BASED ON COMPILED RECORD DATA AND BEST FIT ONTO EXISTWG IMPROVEMENTS. IT 15 POSSIBLE FOR THE LOCATION OF THE SUBJECT PROPERTY TO SHIFT FROM THE PLACEMENT SHOWN HEREON WITH ADDITIONAL FIELD WORK AND RESEARCH. THEREFORE ANY SPATIAL REFERENCE MADE OR SHOWN BETWEEN THE RELATIONSHIP OF THE BOUNDARY LINES SHOWN HEREON AND EXISTING GROUND FEATURES, EASEMENTS OR LEASE AREA IS INTENDED TO BE APPROXIMATE AND IS SUBJECT TO VERIfICATION BY RESOLVING THE POSITION OF THE BOUNDARY LINES. 17. THE CONTRACTOR TO VERIfY THE LATEST/CURRENT RF DESIGN. 18. WHERE APPLICABLE, CONTRACTOR SHALL PROVIDE SEPARATE P�ANS, SPECIFICATIONS, FEES AND PERMITS fOR ANY REVISION TO ANY FIRE SPRINKLER AND/OR ALARM SYSTEM ON THE PREMISES AS MAY BE NEEDED TO COMPLETE THE WORK DEPICTED HEREIN, USING A C-10 LICENSED SUBCONTRACTOR FOR ALL SUCH WORK. (E)SITE ACCESS � �(E) ASPHALT PARKING LOT Y (N) 30'-0"X30'-0" AT&T LEASE AREA W/ (N) CHAIN LINK FENCE (E) PULLBOX W/AT&T POWER P.O.C. (E) PULLBOX W/AT&T TELCO P.O.C. '�] � � i�i� � �,,.,. ; ���. % (E)BUILDWG ;� (E)BUILDING �;,, ,; E���G� P�v� � I� � I ' II / I� i�__ I Y�� � (E) ASPHALT PARKING LOT� — � I —�I I— � I � � ; � � 10'-0" SITE � � I_ ACCESS ROUTE � I_ — � � � I � � I I (E) UTILITY — �i � —� TRENCHING FOR ' —�I FIBER & POWER— z - II I - I- >- � i I � i � — �—� a � � � i� a � � � I_ II - � �I � I I� � Ii P�� \ �""�(.���,;?�1�-��� . . � . _. _ ._r:i� .. . . L.�.� , �. � .. . .�• ..._ - ._... ... �,. . ... ,.-. � � • . • � � ,' ... 4 ' . ' , - �I �� � �� � SEE SITE P�AN �'� — I � — — �I �- � � i I_ �I � I � � lil � - � (N) TEMPORARY C.O.W. (CELL _ _���_=ON WHEELS) UNIT W/(N) AT&T _- �. ANTFNNAC,� F!)IIIP�IFNT (E) CONSTRUCTION SITE ACCESS GATE #4 � � (E)CONSTRUCTION SITE J (E) 8'-0" TALL CHAIN LINK FENCE W/BLACK MESH (E)ASPHALT PARKING LOT � (E) ASPHALT PARKING LOT S TE P�AN �r� 1"=40'-0" 0 20' ao' so' �20' zoo' z � z � C C r� �, I, � NOTICE PROPOSED ANTENNA MAST TO BE ANALYZED BY MANUFACTURER. STREAMLINE ENGINEERING &DESIGN INC. IS NOT RESPONSIBLE FOR THE EVALUATION OF THE PROPOSED COW OR ANTENNA MAST. APPLE WORLD CAMPUS COW CCU2693/CCL02693 190�0 PRUNERIDGE AVE CUPERTINO.CA 95014 ISSUE STATUS Q DATE DESCRIPTION BY 08 12 13 CD 90% A.G. DRAWN BY: A. GOLESORKHI CHECKED BY: C. MATHISEN APPROVED BY: — DATE: 08/12/13 � � �goN � �M� 003¢ vr'�°c osw` o`° w¢= �� �CO� ��''" � ' m`O� o�o �. �� c . � N �foa � LL =p �� � � �ii �%. W L U �i y a �ow •�r �' '3 C C w3wz � tn N a�i �°T< ��� = � ow � m o� o�§ C'i� a�� � ��ms .'� N.�N �o�, C �Y ' z3N8 �/�, ; U i _V ��Y .� `v.7 � °� � " i "ir�":" �U� oaa C'�"S . w � �� � ��z �,: N��= r 3 � � � H cc cri � � J�m 0� O V �z O -�i"�'�"�a, �N �,� �� s';4 � ry,� a �`�a ;:�� SHEET TITLE: SI TE PLAN SHEET NUMBER: A-1 I I � I (N) 30'-0"X30'-0" AT&T LEASE AREA WJ(N) 6'-0"CHAIN LINK FENCE-- (N) TEMPORARY C.O.W. (CELL ON WHEELS) UNIT W/(N) AT&T ANTENNAS&EQUIPMENT- � ,� ---- ------ , ---30'-0"-- � - � I i I �� �i —d—0—a—0�—� —��—O �—0�—O�—�--0--0----0 i � � �, � (E� CONCRETE CURB� TYP �' I/f"���'u3!����'M/�.��'J/„��rfiirf���✓�xifr"�,z7�'/a�l�/,,��/�,�',�"�/,; �u�;nk��z�ra""���;�%�v';� I � � q � � ___--� � i I � �—(E)PARKING STRIPE, TYP I qqq � I I (N) 02" CONDUIT FOR POWER� � �, ���� � (E) PULLBOX W/AT&T POWER P.O.C.� � I '� �o�Gy � �(N)REMOVABLE TONGUE � � � I (E)PULLBOX W/AT&T TEL.,.,,..,..,. � � (N)02"CONDUIT FOR TELCO � r, T 9 ��, (N) GPS ANTENNA � `��s: P P P P P P ----- ------ ------------- ----- 4'-4" (N) METER � �BI(N) MAST W�(3) (N) FIB/P F�/ `P FIB/P FIB/P FI /P AT&T ANTENNAS& � (1) (N)RRUS-11 �---- -- ----�--- - - --------------� ; (N) 2" CONDUIT FOR��,�Y%�'�',.- ' .,,�?�,. o e � e FIBER &DC POWER / -o a _ � AZIMUTH = 90'� SECTOR C ��� T T P,�������0-T I S�G'� i (N) 23" RACK W/(1) (N) 6601-DUL UNIT—� (N) 26" BATTERY RACK �I ���;,'�, (N) 26" LINEAGE POWER RACK I (N) OUTRIGGER, TYP OF 4 �3'—s° , � � � �—o--��--0�-0 (N) ACCESS DOOR, TYP OF 2 ' � NOTE: ALL(N)EQUIPMENT CABINETS I &EQUIPMENT RACKS TO BE INSTALLED W/ELECTRICAL ISOLATION PAD �i i NOTICE PROPOSED ANTENNA MAST TO BE ANALYZED BY MANUFACTURER. STREAMLINE ENGINEERING&DESIGN INC. IS NOT RESPONSIBLE FOR THE EVALUATION OF THE PROPOSED COW OR ANTENNA MAST. I 6 t� -� � -�Z�6 4,. � 0 4" _�6 _. B B 2'-4" ,�—�� � � �� I (N) I � (N) I I �I HVAC / � HVAC I � ' / \ I �---- � i � � ---J II i � li �� �� II _� ��—_JJ 4'-6" (E) 8'-0" TALL CHAW LINK FENCE W/BLACK MESH- _ � � _ > (N)MAST W/(3)(N) ____30'-0"/ AT&T ANTENNAS & �i� (2) (N)RRUS-11'S � I (24) (N) RUNS OF COAX p CABLE / (N) 3206 RBS!'ABINET � (N) 3206 RBS CABINET P � O \N) 3206 RBS CABINET � � � � EN�ARGED S TE P�AN .,.� ,"=s'—o„ 0 1' 2' 3' 4' S' 10' 15' 25' (N) GUY WIRE, TYP OF 8 i � � �i 'i I i I , ' 10'-0" SITE � ACCESS ROUTE � I i I I ` �i (N) 12'-0" DOUBLE SWING ACCESS GATE FIB/P FIB/P FIB/P FIB/P FIB/P FIB/P APPLE WORLD CAMPUS COW CCU2693/CCL02693 190�0 PRUNERIDGE AVE CUPERTINO.CA 95014 ISSUE STATUS p DATE DESCRIPTION BY 08 12 13 CD 90� A.G. DRAWN BY: A. GOLESORKHI CHECKED BY: C. MATHISEN APPROVED BY: - DATE: 08/12/13 --------------------T----------------------------- � � �_=o� � � a "g�� 0 �; �°� �o;� U°'c°o ��w` � a� wo� m�°�° �w'� e.'�".'.`,'1��� m�� `<�' „�„'- X w�°o (E)UTILITY TRENCHING �C`� �� . 6, � ��oa FOR FIBER & POWER ��� � �;E Q =� c ww � , W L O a=°� �� U U�w •�*�. ' •� c c w3w� �`.a cn °�,' � Q�=< '1��,�G'--�,��i�"L�'7 ""'i-� >o� �ooN . . - . � �, � a� �_ws m� : ,. �� - � .�> ,�..�... ��., a��i��N �a° _ � � -��-1� �.. � @Y� N;N �Y p u z i .: •. �. I � � �o.� `s�<w 1 � ,. t ,V �r.� y': :� i .*.,,�"'�" � V U� z N . .,� .._ � � � w ��s�^�� � sz�V ;� �z APN: 316-06-033 (E) CONSTRUCTION SITE ACCESS GATE #4 � �� II �� I1 I 1 — �— — • �—� -- -- — i \ / \ / � / \ � � i � i � i � i � i � � / � i � � � � � � � � � , , , , , , , , � � � � �__---��� \���----_J � ���: a` � � � O � H cc c�i � � m� � � �U O �O �Z '��'�w„°�;�A O Q �;�4h �� ' 9� �u� �u i; J • y a �,.,�-.��� SHEET TITLE: EN�ARGED SITE P�AN SHEET NUMBER: A-2 (N)ANTENNA PUCK &PLATE W/ ANTENNA MOUNTING POLE PER nn.�.n.in rn�nrn-i nv riir.i uirrr NORTH E�E�AT ON �°=�'-o„ � TOP OF(N) AT&T ANTENNAS t55'-0" A.G.L. � TOP OF(N) ANTENNA MAST t54'-11° A.G.L. � RAD CENTER OF(N) AT&T ANTENNAS f52'-11" A.G.L. GROUND LEVE� 0'-0" (N) TEMPORARY C.O.W. WHEELS) UNIT W/ ANTENNAS &E� (E) 8'-0"CHAIN LI FENCE W/BLACK ME i r.��_.;��i3—��i , . . � �Y . �,� � . .�. �-1�� ' . . � . . . ,� . _..� � . •- � , � EAST E�E�ATON �°=,'-o„ APPLE WORLD CAMPUS COW CCU2693/CCL02693 190�0 PRUNERIDGE AVE CUPERTINO,CA 95014 ISSUE STATUS Q DATE DESCRIPTION BY 08 12 13 CD 90� A.G. DRAWN BY: A. GOLESORKHI CHECKED BY: C. MATHISEN APPROVED BY: — DATE: 08/12/13 �o� �c e=°w � � � oN og� 6��� 0 3¢ U o� �o� @�� � t""i��� m�� �`�" � �o�o .� �: .��, m ��a �..� , c� �� < �� �.'Z� : C� oE ww t7.'s w L ° ��� �a • °pw .� .� � � w�a� � � � � N�ya ��� � > �wm `'`"' m o� .��� ci� u�� � ��ms .C, � a� ' `n �zr ��+..rri o Y c Q w<� ` : U� > �iNw -_ ��:.� m@ Y o�i i Q� � � p.� �baw � y; ��� gao � w �"_� �,. a==� � N�°z � � � � E � cc ri � � J�m 0� O V �O � �..��,, O� u �NQ ��% �W �• °' �J °d';� �a SHEET TITLE: E�EVATIONS SHEET NUMBER: A-3 POWERWAVE P65-15—XLH—RR (s.o") I I (12.0") ,� 'r' i � � LEFT VIEW FRONT VIEW � A TE f�A D E TA Y2=1-0" ;��`�� ,� I� ISO �IEW MOUNTING HARDWARE (VARIES) 02�" O.D. GALV STD PIPE PANEL ANTENNA (VARIES) (1; SIDE VIEW 2 A TE A MOU T DETA 1 =1-0 ��26.����� TOP VIEW (22.3") (2�.5") �� T-�- a � ��~��fl9 +'� ��� r_- .--� _,� � �� �. (84.0") �,�,_� FRONT VIEW (10.0") (5.0") �o:, � ,`^ _^�{ � ��'-'� LINEAGE POWER 26" RACK - �l', #CC848828938 � - (6.1")-1 � ,�(i5.o) SIDE VIEW DC POWER 26" RACK DETA � 6 y.,=,�-o„ �(17.8)� T(1 D \/I C 1�1 ERICSSON RRUS-11 ;7.2") � FRONT VIEW RIGHT VIEUV ,3 RRUS- 11 DETA !_ 1 =1.-0 WEIGHT- 50LBS �(26.�"/� TOP VIEW (22.3") �z�.5") �� (84.0") ,�- � �I � `^^^^ � _r,_ FRONT VIEW i �,�Q� 4 GPS DETA 3=1-0" (10.0") �5.0°� LINEAGE POWER 26" RACK #CC848828938 �-- MARATHON 12V155FT lf BATTERY, TYP �'_ -� _ u-- -- �6.���� ` I_ — '.. � ,��,5.0) SIDE VIEW 26" BATTERY RACK DETA � 7 y,._,'-o., 0.750 HOLE, TYP 4 PLACES �-� (15.0) ;..:....a....:..� (10.5) ,�L=7 tl I (22.8) I ,�-(27.5) � MOUNT W/(4) MOUNTING TOP VIEW SCREWS CHATSWORTH PART# 13855-703 OR EQUIVALENT - � � (N) 6601-RBS EQUIPMENT i � i � � 12-24, THD MTG HOLES E I 135 PLS(45 RMU) � (84.0) SIDE VIEW ' 0.656 HOLE, �i-'o TYP 12 PLACES (23.0) O � 0 � O (39.0) O oo, (4A�. .. � FRONT VIEW APPLE WORLD CAMPUS COW CCU2693/CCL02693 19050 PRUNERIDGE AVE CUPERT[NO.CA 9�014 ISSUE STATUS p DATE DESCRIPTION BY 08 12 13 CD 90% A.G. DRAWN BY: A. GOLESORKHI CHECKED BY: C. MATHISEN APPROVED BY: - DATE: 08/12/13 ^ � Noo� � � o = �o �o;� " RA,CK W 6601 DETA � U�� pVwa 23 SE SM C / °`� np°� ��� _ �� 5 ��� °°�°' �ooa ,.�. X Y2�=�_�" ��� �� �C rn �p ���� � �� � �' � = ww � w= � _�_ C"�; � a' � ` � �ow •��„r,.,�._.i:: .� c c w.3 w z ��� � u�i N N°i� �� C a � �.+�.... : m �� ��w g Q� a�� �' ��ms �� � � 1 N ��S -����' 0 Y � �/�, w f6 U � ���w _V e�+Y f U�u � �i. � 0— �y u � � � LLn �`�"'1 � ��� =a o `� W �=�w � �, N� � a��z � Ww�� �: � •1"'u,�':.-��1�'-�"r-f' _ ' : � . �G��J' - � . `-��: ... .. �.....r�`�. _. � � ' � :4 �(23.6')� (15.8") � ERICSSON RBS 3206 TOP VIEW � I i (79.8") ' i I I �RONT VIEW RIGHT VIEW 8 RBS DETA � YZ=1—0" WEIGHT = 441 LBS � � � � � co c�i � � J� m � � �U O �z O "�,�;."�,�, z ��,�����¢ �j J ' ., , � �a -=�.�,�� SHEET TITLE: DETAI�S SHEET NUMBER: A-4 OUTRIGGERS FRuNl (EXTENDED), � OUTRIGGER JAC ���'����-� -��' �i-��� 13.._ . �.,,.�„��,,.,,. �, , .,.,", .,,.,, BACK VIEW ,y„� �t3'- ,�- -- ---- �,o�—,o°� I 60' MAST, TYP OF 2 TRANSFER SWITCH REMOVABLE TONG�JE ,�— (7�-3°) V A/C UNIT � N A/C UNIT C�O�W� (CE�� ON '�UHEE�S) DETA � 1 y„_,'-o" - - - -- --- - SIDE VIEW APPLE WORLD CAMPUS COW CCU2693/CCL02693 I 190�0 PRUNERIDGE AVE CUPERTINO.CA 95014 � ISSUE STATUS p DATE DESCRIPTION BY 08 12 13 CD 90% A.G. DRAWN BY: A. GOLESORKHI CHECKED BY: C. MATHISEN APPROVED BY: - DATE: 08/12/13 �o� �o a�°p ' � V �io: � � � �� ��M� a°o�¢ - a�C�O o5w` ���:. U�cG a w'o� �x ��� z¢R `i1'1 ws [��o� a�� � s. y� Eo` �w y ��� .0� @ ��oi � �i � °'� �p c ti� w r ° �°� � �� V uow •�r s �j C C w3w3 _ �� � N N Noia '� y C w `�`'�•� ) owmw W - m 0 � zow8 ��::'�.._.�: � a � � �' �=ms c"";: � �'�� :��� "+� o Y c N-�s' �r U��> �>�w � � �y o;zi � � N C_ c`i�<w 4.... ,� �c.� f6 " : � ,- � � d aa z, � w o � ��_� � sz�z � y�� ww�� �'_ �3 ' OF2 � a' � � _ � co M � � J�m 0� p U �O � �'"�;"'� �N �����,, / � y� 4 7.;''y. W ?�, �J 1/ y.';a;/�� d � SHEET TITLE: DETAI� SHEET NUMBER: A-5 �❑ � IN A E OF CS EMERGENCY CALL - - 2-6662 1 800 83 Site No: CCU2693 � � � i Beyond This Point you�e entering an area where radio frequency emissions may exceed the FCC General Population Exposure Limits. Follaw all posted signs and site guidelines far working in a radio frequcncy environment. Ref FCC 47C,FR 1.130?(b) Cingular Wireless T�'r CA� CAU T ON S GN 2 TYP CA� CAU T O�J S �N 1 CONSTRUCTION NOTES 1. EXISTING BUILDING CONSTRUCTION CONDITIONS INDICATED ON THE DRAWINGS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO PROCEEDING WITH CONSTRUCTION OR ORDERING OF MATERIALS. IF EXISTING CONDITIONS DO NOT ALLOW FOR DETAILS OF CONSTRUCTION AS SHOWN ON THESE DRAWINGS, NOTIFY ENGINEER OF RECORD FOR RESOLUTION PRIOR TO PROCEEDING. CONTRACTOR SHALL EXPOSE AND REVIEW EXISTING CONDITIONS IN A TIMELY MANNER SUCH THAT ALTERNATE DESIGNS OR DETAILS, IF REQUIRED MAY BE GENERATED WITHOUT DELAY TO THE PROJECT. 2. D U R I N G C O N S T R U C T I O N, T H E C O N T R A C T O R S H A L L N O T A L T E R, D A M AG E O R R E M O V E A N Y P A R T O F T H E E X I S T I N G S T R U C T U R E U N L E S S SPECIFICALLY DETAILED ON THESE DRAWINGS. 3. THE INTENT OF THESE DRAWINGS IS THAT THE WORK OF THE ADDITION, ALTERATION, REHABILITATION, OR RECONSTRUCTION IS TO BE IN ACCORDANCE WITH THE 2010 CBC. SHOULD ANY EXISTING CONDITIONS SUCH AS DETERIORATION OR NONCOMPLYING CONSTRUCTION BE DISCOVERED WHICH IS NOT COVERED BY THE CONTRACT DOCUMENTS WHEREIN THE FINISHED WORK WILL NOT COMPLY WITH THE 2010 CBC, A CHANGE ORDER, OR A SEPARATE SET OF PLANS AND SPECIFICATIONS, DETAILING AND SPECIFYING THE REQUIRED WORK SHALL BE PREPARED AND SUBMITTED TO AND APPROVED BY THE BUILDING DEPARTMENT PRIOR TO PROCEEDING WITH THE WORK. 4. ALL WORK AND MATERIALS SHOWN ARE NEW UNLESS INDICATED AS EXISTING(E). 5. IT MAY BE NECESSARY TO REMOVE ARCHITECTURAL FINISHES, PLUMBING PIPES AND FIXTURES, ELECTRICAL CONDUIT, FIXTURES, PANELS, BOXES, TELEPHONE OR FIRE ALARM WIRING AND FIXTURES OR OTHER NON-STRUCTURAL ITEMS TO INSTALL STRUCTURAL WORK AND MATERIALS SHOWN ON THESE DRAWINGS. SUCH ITEMS SHALL BE REMOVED, REPAIRED AND/OR REPLACED TO MATCH PRE-CONSTRUCTION CONDITIONS AT THE CONTRACTORS EXPENSE. 6. ALL WEATHER PROOFING. INCLUDING BUT NOT LIMITED TO TORCH DOWN, CAULKING, Z-FLASHING OR ANY OTHER MATERIAL THAT MAY BE ALTERED DURING INSTALLATION SHALL BE REPAIRED REPLACED AND/OR MODIFIED TO ENSURE THE BUILDING AT THE INSTALLATION SITE IS WEATHER PROOF. 7. ANY PROPOSED SUBSTITUTIONS FOR STRUCTURAL MEMBERS, HARDWARE, ANCHOR TYPES, OR DETAILING INDICATED IN THESE DRAWINGS SHALL BE SUBMITTED TO AND REVIEWED BY THE ENGINEER OF RECORD PRIOR TO ORDERING MATERIALS. SUCH REVIEW SHALL BE BILLED ON A TIME AND MATERIALS BASIS TO THE CONTRACTOR WITH NO GUARANTEE THAT THE SUBSTITUTION WILL BE ALLOWED. �XTERIOR SIDE FACILITY SIDE IVACY SLATS PRIVACY ,',',``': � �� 6,I�„ ��/„ ' �I I '' 3'-0"2�_9�� I � II I, ', �� � ��— ,� � �, 3 012°,�- 02%" ASTM A53 SCHED 40 GALV POST TYPICAL �2 T!NNED COPPEP, CADWELD TO CORNER, GATE, TERMINAL, OR PULL POST TIED TO GROUND RING TYP. GROUND RING CORNER POST DETA � 3 __ _- --- ____ _ __-- Y��-,�-o�� 6'-0" , � �, CHAIN LINK �FABRIC �%r� � � i :, 3,I p..2'-9" �� �� � . , 3°J ' -�'012"� CHAIN �INK FENCE NOTES 1. INSTALL FENCING PER ASTM F567 AND F1083, SWIN�GATES PER ASTM F900 2. GATE, CORNER, TERMINAL OR PULL POSTS SHALL BE 02%" SCHED 40 FOR GATE WIDTHS UP TO 6 FEET OR 12 FEET FOR DOUBLE SWING GATE. 3. LWE P O S T S SHALL B E 0 2%a' S CH E D 4 0 P I P E. 4. GATE FRAMES SHALL BE 1Y2° SCHED 40 PIPE. 5. TOP AND BRACE RAILS SHALL BE 01Ye" SCHED 40 F'IPE. 6. FABRIC SHALL BE 12 GAUGE CORE WIRE SIZE 2"MESH, CONFORMING TO ASTM A392 CLASS 1. 7. ALL FENCING SHALL BE GALVANIZED STEEL. 8. TIE WIRE SHALL BE 11 GAUGE MIN. INSTALL A SINGLE WRAP TIE WIRE AT POSTS AND RAILS AT MAX. 24" MAX IPJTERVALS. INSTALL HOG RINGS ON TENSION WIRE AT 24" INTEPVALS. 9. TENSION WIRE SHALL BE 7 GAUGE. 10. GATE LATCH SHALL BE 01�" O.D. PLUNGER ROD W,� MUSHROOM TYPE CATCH AND LOCK. 11. BARBED WIRE (IF USED) SHALL BE DOUBLE STRAND 12 GAUGE TWISTED WIRE TO MATCH WITH FABRIC, 4 PT. BARBS SPACED ON APPROXIMATELY 5" CENTERS. �� ���.��;: � '` 02%" ASTM A53 SCHED �! 40 GALV POST TYPICAL '�I � � �I I�.��� : :r:i ,, BOTTOM TENSION WIRE GROUND RING I�I� j; " ���' - � NE POST DETA � _ _- --------- ---- --_-- 4 Y2�=,�-o„ PRIVACY SLATS GATE GROUNDING STRAP #:? TINNED COPPER CADWELD TO CORNER, GATE, TERMINAL, OR PULL POST TIED TO G�OUND RING TYP. CIAGONAL ROD W/ S�EEL TURNBUCKLE ALPHA SECTOR BETA SECTOR GAMMA SECTOR ANTENNA & CABLE SCHEDULE ANTENNAS ANTENNA ANTENNA MODEL RAD CENTER AZIMUTH POSI TION A1 P65-15-XLH-RR 52'-11" 335' A2 P65-15-XLH-RR 52�-11" 335' Bt P65-15-XLH-RR 52'-11" 235' 62 P65-15-XLH-RR 52'-11" 235' C1 P65-15-XLH-RR 52'-11" 90' C2 P65-15-XLH-RR 52'-11" 90' NOTE: CONTRACTOR TO VERIFY LATEST RF DESIGN TMA OR DIPLEXER NO NO NO NO NO NO CABLING N0.OF COAX DIA. COAX COAX CABLES LENGTH 4 �" 70' 4 i�" 70' 4 �" 70' 4 �" 70' 4 �" 70' 4 �" 70' NORTHERN CALIFORNIA ANTENNA COLOR CODE SECTORS A, B, & C 1900 GSM TX 1/RX 1 RX 2 TX 3/RX 3 RX 4 TX 5/RX 5 RX 6 ALPHA UMTS 1900 4 BROWN 4 ORANGE 4 BRN/1 RED 4 ORN/1 RED 4 BRN/2 RED 4 ORN/2 RED TX 1/RX 1 RX 2 TX 3/RX 3 RX 4 TX 5/RX 5 RX 6 ALPHA UMTS 850 5 BROWN 5 ORANGE S BRN/1 RED 5 ORN/1 RED 5 BRN/2 RED 5 ORN/2 RED TX 1/RX 1 TX 2/RX 2 TX 3/RX 3 TX 4/RX 4 TX 5/RX 5 TX 6/RX 6 ALPHA LTE 700 6 BROWN 6 ORANGE 6 BRN/1 RED 6 ORN/1 RED 6 BRN/2 RED 6 ORN/2 RED TX 1/RX 1 TX 2/RX 2 TX 3/RX 3 TX 4/RX 4 TX 5/RX 5 TX 6/RX 6 ALPHA LTE 1700/2100 � gROWN 7 ORANGE 7 BRN/1 RED 7 ORN/1 RED 7 BRN/2 RED 7 ORN/2 RED TX 1/RX 1 RX 2 TX 3/RX 3 RX 4 TX 5/RX 5 RX 6 BETA UMTS 1900 4 YELLOW 4 BLUE 4 YEL/1 RED 4 BLU/1 RED 4 YEL/2 RED 4 BLU/2 RED TX 1/RX 1 RX 2 TX 3/RX 3 RX 4 TX 5/RX 5 RX 6 BETA UMTS 850 5 YELLOW 5 BLUE 5 YEL/1 RED 5 BLU/1 RED 5 YEL/2 RED 5 BLU/2 RED TX 1/RX 1 TX 2/RX 2 TX 3/RX 3 TX 4/RX 4 TX 5/RX 5 TX 6/RX 6 BETA LTE 700 6 YELLOW 6 BLUE 6 YEL/1 RED 6 BLU/1 RED 6 YEL/2 RED 6 BLU/2 RED TX 1/RX 1 TX 2/RX 2 TX 3/RX 3 TX 4/RX 4 TX 5/RX 5 TX 6/RX 6 BETA LTE 1700/2100 � YELLOW 7 BLUE 7 YEL/1 RED 7 BLU/1 RED 7 YEL/2 RED 7 BLU/2 RED TX 1/RX 1 RX 2 TX 3/RX 3 RX 4 TX 5/RX 5 RX 6 GAMMA UMTS 1900 4 VIOLET 4 WHITE 4 VIO/1 RED 4 WHT/1 RED 4 VIO/2 RED 4 WHT/2 RED TX 1/RX 1 RX 2 TX 3/RX 3 RX 4 TX 5/RX 5 RX 6 GAMMA UMTS 850 S VIOLET 5 WHITE 5 VIO/1 RED 5 WHT/1 RED 5 VIO/2 RED 5 WHT/2 RED TX 1/RX 1 TX 2/RX 2 TX 3/RX 3 TX 4/RX 4 TX 5/RX 5 TX 6/RX 6 GAMMA LTE 700 6 VIOLET 6 WHITE 6 VIO/1 RED 6 WHT/1 RED 6 VIO/2 RED 6 WHT/2 RED GAMMA LTE 1700/2100 TX 1/RX 1 TX 2/RX 2 TX 3/RX 3 TX 4/RX 4 TX 5/RX 5 TX 6/RX 6 7 VIOLET 7 WHITE 7 VIO/1 RED 7 WHT/1 RED 7 VIO/2 RED 7 WHT/2 RED WHEN ANTENNA LINES ARE DIPLEXED, THE COLOR CODE OF THE HIGHEST FREQUENCY PREVAILS (I.E.1900 UMTS DIPLEXED WITH 850 GSM SHOULD HAVE COLOR 4 BANDS) ����..V�- ,;Zc r3 -� _ C� .— �`'i -.�` • . . ,. . .. _.-,:._ : . : --� � �'012°;� DOUB�E GATE DETA � 5 y„_,'-o" --- - TOP BRACE RAIL GATE LATCH W/LOCK POLO LATCH GATE FRAME 02�" GATE POST STRETCHER BAR FINISH GRADE OR GROUND GROUND RING CONCRETE OR SAKRETE CAST-IN-PLACE GALV. MTL "MUSHROOM" PER MFR.SPECS (TYP) SET IN CONC. BASE APPLE WORLD CAMPUS COW CCU2693/CCL02693 190�0 PRUNER[DGE AVE CUPERTINO.CA 9>014 ISSUE STATUS p DATE DESCRIPTION BY 08 12 13 CD 90% A.G. DRAWN BY: A. GOLESORKHI CHECKED BY: C. MATHISEN APPROVED BY: - DATE: 08/12/13 Woo � � �__� 0 rn o r' :o�¢ Q rn� o°� < s� v o� awa� m`D C° � t'+,�'l1��< m�rn w � .� �� �a, � Loo � LL a �u � �� � � � ¢w 0 ��Li �; W r v �°� � ����;. d u o w �: d �w�r ' •� c c w 3 w? � � � � ¢��a �� c �� � � owm W m p � ��8 " 'r, ; d c � ��ms � �#� N� N a i z =-•�� � U Y c N w�8 'V '.� U > �3�w � �Y p�jzi �� �:i.1 � � o.� �"� -�..~' �, �"� a o c'-�".s �; � W °�_ , �: N� �w=� �' N��w &< °3 � � � � H co cri � � J�m o� O V �Z O �� tn Z "�, � � O Q ;�� �� 0 ;�� �a d�-.;,��,� SHEET TITLE: DETAILS SHEET NUMBER: A-6 E�ECTRIC �EGEND MI MECHANICAL INTERLINK OMETER o CIRCUIT BREAKER � SERVICE GROUND S N G�E � N E D AGR AM - WIRED CONNECTION � TIMER SWITCH, WATERPROOF \O� OUTDOOR LIGHT � � � GFI OUTLET, WATERPROOF ELECTRICAL NOTES 1. ALL ELECTRICAL WORK SHALL CONFORM TO THE CEC AS WELL AS ALL APPLICABLE STATE AND LOCAL CODES. 2. CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUIT, CONDUCTORS, PULL BOXES, TRANSFORMER PADS, POLE RISERS, AND PERFORM ALL TRENCHING AND BACKFILLING REQUIRED IN THE PLANS. 3. ALL ELECTRICAL ITEMS SHALL BE U.L. APPROVED OR LISTED AND PROCURED PER PLAN SPECIFICATIONS. 4. ALL CIRCUIT BREAKERS, FUSES, AND ELECTRICAL EQUIPMENT SHALL HAVE AN INTERRUPTION RATING NOT LESS THAN THE MAXIMUM SHORT CIRCUIT CURRENT TO WHICH THEY MAY BE SUBJECTED WITH A MINIMUM OF 10,000 A.I.C. OR AS REQUIRED. 5. THE ENTIRE ELECTRICAL INSTALLATION SHALL BE GROUNDED AS REQUIRED BY ALL APPLICABLE CODES. 6. ELECTRICAL WIRING SHALL BE COPPER #12 MIN WITH TYPE XHHW, THWN, OR THHN INSULATION. 7. ALL OUTDOOR EQUIPMENT SHALL HAVE NEMA 3R ENCLOSURE. 8. ALL BURiED WIRE SHALL RUN THROUGH SCHEDULE 40 PVC CONDUIT UNIESS OTHERWISE NOTED. 9. A GROUND WIRE IS TO BE PULLED IN ALL CONDUITS. 10. WHERE ELECTRICAL WIRING OCCURS OUTSIDE A STRUCTURE AND HAS THE POTENTIAL FOR EXPOSURE TO WEATHER, WIRING SHALL BE IN WATERTIGHT GALVANIZED RIGID STEEL OR FLEXIBLE CONDUIT. 11. WHERE PLANS CALL FOR A NEW ELECTRICAL SERVICE, PRIOR TO SUBMITTING BID, CONTRACTOR SHALL VERIFY PLAN DETAILS WITH THE UTILITY'S SERVICE PLAN &REQ'MTS INCLUDING SERVICE VOLTAGE, METER LOCATION, MAIN DISCONNECTING MEANS, AND AIC BRACING REQ'MT, AND SHALL OBTAIN CLARIfICATION FROM THE PROJECT ENGINEER ON ANY DEVIATIONS FOUND IN THESE PLANS. UTI�ITY SERVICE NOTE CONTRACTOR SHALL COORDINATE NEW ELECTRICAL SERVICE DROP & TELCO SERVICE EXTENSION TO SITE COMPLETE FROM SERVICE APPLICATIONS TO TURN ON OF(N) SERVICES, INCLUDING PROVISION &INSTALLATION OF ALL CUSTOMER-PROVIDED MATERIALS& INSTALLATIONS, INSPECTIONS BY UTILITIES AND/OR JURISDICTIONS,ETC. NOTIFY THE ENGINEER OF RECORD OF ANY DISCREPANCIES WITH THESE PLANS AS SOON AS POSSIBLE. PANEL SCHEDU�E NAI�EPLATE: PANEL A SC LEVEL: 10,000 VOLTS: 120V/240V, 10 LOCATION : INSIDE BUS AMPS: 200A I�OUNTING: WALL I�AIN CB: 200A 0A e� BKR BKR en �e LOAD VA LOAD VA LOAD DESCRIPTION AI�P/ CIRCUIT NO AMP/ LOAD DESCRIPTION LOAD VA LOAD VA POLE POLE 3400 AIR CONDITIONER�1 60/2 1 2 60/2 SURGE ARRESTOR 30 3400 " " - 3 4 - " " 30 500 EXTERIOR,INTERIOR LIGHTS 20/1 5 6 60/2 AIR CONDITIONER #2 p 360 RECEPTACLES /EXT RECEPT 20/1 7 8 - " " 0 3016 SHELF 1, RECT 1 &2 40/2 9 10 40/2 SHELF 3,RECT 1 &2 3�16 3016 " " - 11 12 - " " 3016 3016 SHELF 1,RECT 3&4 40/2 13 14 40/2 BLANK 3016 " " - 15 16 - " " 3016 SHELF 2, RECT t &2 40/2 17 18 40/2 " " 3016 " " - 19 20 - » " 3016 SHELF 2, RECT 3&4 40/2 21 22 40/2 " " 3016 " " - 23 24 - " " 15964 15824 PHASE TOTALS PHASE TOTALS 3046 3046 TOTAL VA= 37880 TOTAL AMPS 158 NOTE: AIR CONDITIONING UNITS ARE PROGRAMMED TO WORK IN AN A�TERNATING SEQUENCE, NO TWO UNITS WILL OPERATE AT THE SAME INSTANCE. 'i��,��e�3��� - , �l�� - l�, � r , .. ----�.• APPLE WORLD CAMPUS COW CCU2693/CCL02693 190>0 PRUNERIDGE AVE CUPERT[NO,CA 95014 ISSUE STATUS Q DATE DESCRIPTION BY 08 12 13 CD 90% A.G. DRAWN BY: A. GOLESORKHI CHECKED BY: C. MATHISEN APPROVED BY: - DATE: 08/12/13 , _wo¢ t � �_ "z== 0 °'°°' ¢°N� U�(�O o5w` �CO aw°�z ��� m<p� �o°o ..� �� �� � p��a � � LL :� �vu► �; c� � � � w w � `""" w L � a�°� y a � �ow ���.;: �3 y y �ad� � � �, a� �o> �� c ��;� ) owm ``i'�', m o � :'oN� C �� �, �_ms � � >N �s= =—•r::;::� O Y c ,�-� �S �,.;�`.. �p U � 0 3 N w � �-'Y .'�� Q� 'u� ` ""`� .r..�'�'.' � ��� a o �.--� � � w =�_ �` wu3z 4� °� � � � � x � rS � � J�m o� O V �O H ���;�. O Q ��� �� �" �a �� ���� SHEET TITLE: E�ECTRICAL P�AN & NOTES SHEET NUMBER: E-1