TUP-2013-04b CITY OF CUPERTINO
10300 Torre Avenue, Cupertino, California 95014 (408) 777-3308
To: Mayor and City Council members
Chairman and Planning Commissioners
From: Aarti Shrivastava, Director of Community Development� �
Prepared by: Stephen Rose, Associate Planner
��—
Date: September 16, 2013
Subject: Director's Temporary Use Permit, TUP-2013-04 to allow an AT&T COW (cell
on wheels) facility for a period of one year at 19050 Pruneridge Avenue
(Apple); APN: 316-06-033, to allow time to identify and permit another
permanent cell site.
Chapter 19.12.030 of the Cupertino Municipal Code allows for
administrative approval of a temporary use permit, authorizing the use of
a site in any zoning district for a temporary use. The Director reports
his/her decision to the City Council & Planning Commission in time to
allow an appeal of the decision within fourteen calendar days.
DISCUSSION
The applicant, jason Osborne (Osborne & Associates, LLC), on behalf of AT&T, is
requesting approval to allow the installation of a temporary unmanned wireless cell
facility, COW (cell on wheels), for a period of one year in the parking lot of the subject
Apple owned property. The temporary facility is needed as Apple will be demolishing
(as part of the Apple Campus 2 project) the building upon which the existing cell tower
is located. The proposed facility will prevent any interruption in cellular service while
AT&T works on identifying and permitting a new permanent cell site.
Location
The subject property is an existing office building occupied by Apple, bounded by
Pruneridge Avenue to the north, N. Tantau to the east, and other Apple office buildings
to the south and west.
TUP-2013-04
19050 Pruneridge Avenue Temporary COW Page 2
�-'� �
r---,'"r,,,�
�y� .._,.—__ _—
}�.2 v�'•. � _._'.. "'._ iPa'EFil NE r�l.\
k't�� Y};i �:`,
�_ ___�__! . i —_,,� �1�
y �?SiIE 4:/S.l:—.,,,� f.r%�r""J ,._� _ _ . . . ' . . �I�
� . _ �
1G j�~ �� .. i
I
i i
i � ,
I i � ..._ 9 � e r . i �. i S
; i 1 � ` :�_ . ' - i
i ..... �
—,.—,�'__�� ..._ I � I ; �.�,.... , , .. ,.:. _. �
I I
- c�r....°'mwr.�w.��t.-�
.w
�, _ r I � �
1 �
______---""`V".'.\� __W r � � I�V , ._
_____--- �,} �—����� 'I '� � (� ,�;��-� �' y
1 4 Sc iG.1E i 1 ....� �..... . I �.. �.. I ....
t I
�.-I?:9°XUl P+N:IY:�lvi./ ....... i � .. 'E`,.:Rlfii .. . I Y i S
TFBI:)W�:eCs
tTi6�1 PvV(k-,, I J.':,.
� � � � � l .��ii .�._v'J_"2� . I I 'h
� � R'i
y t .. i ' _as�.- ...
� i �
� - � � ( � _I _ ,
-�-- , , , �
_ ,
� � , ....... 1..... ' EE ai?E L r' � �i .
;.x°as�-e• , i i ,.
.ixt l['#xEa wi � � ....... . � . , � i E T
.�:qltk IFF FFM"S � �� . . { , t � � � �
� 1
tF`^YLLLa1k ti ATtI ",nFR?.6.(.—� � 1 ` f �
t[raiva r,n s.ia:o re.c�..� � �.y.1 � f� vu.:�r+w�i�r-
`..,,/ .: , �•, - s m�at..s:cs.;°tu -;E s�'riu:xua.ta�
_m�vm..,F uar s/p}nt:r r �:e x/�.ie:x 1�.at ? �
_ - ,.�_�n+i!CVNS k f48'�FAf �/� I
` _. { i i-- -— � — � � — � --
,� ~ � � —<;—e—t,
�...... .
�r�,u� ce u�. f � �l
F{ ,
\ .ti ,.-,»..:� � iEi'-"�3T#ICT:a J
�., I z�a,c¢,;�rtµ /
j.. 4 r C6 A�NLLf?lx'KI�L'�T!
� b 1
I {
�
� j � . ,.. .. ...
� !-tF):WS1k:CRan 9R.'
� (' �
� �".iW.:l�'L
� �
4
��ITE f;.,L:�.ti
" ,w-s� ti.;TIi;E
� vwx��s��vrzw r.:a r��e.�nE er
rw:a�on�m.artaw�*e Evui¢�:i�:�a
iMC.M;N51 KS?il�itlE PoR ME E�fLWi11:T:t
itE?'e�>:.�;f.M!'J'i M31EJe�.kASi
The temporary COW is proposed at the southwest corner of the project site.
Equipment
The proposed equipment includes a new temporary unmanned mobile
telecommunication facility consisting of a new AT&T equipment/battery cabinet, two
new masts supported by coaxial cable, 6 antennas, 3 new RRU's, and a GPS antenna.
Overall the facility will be 55' tall, 30' long and 18' wide once setup.
TUP-2013-04
19050 Pruneridge Avenue Temporary COW Page 3
-:x;=rtrcvu<..;;a x r��.�«;
�'l�,cKw<.v«��nM1�;��xc=�:
i fi K AiST Rl1EItA➢�. �� �i ldW`:�1<.IS.�PY F.;I.W[ii
...... ..... ... ....... . ..................................
.. ..SS :.L � . �4,„iRi 4v1Eti F TY_f E
r. T. �,F k tA1CIH�YP�i ... \_._..._.. __.____ /
—� 3S9'-'t'h�L - � . {.
�+;'�'1ER'F'4'�FTbT N:iE`�'��i . #.
♦ t_�I'-'i'{G.L.
-.`.i A�:TE4'1A u�S1,T'M1'�F 2
�//
'i'; N1:�t. ..,. I �14�:i::;Y fi7'�'2.TY'f�!!
N�'::RTE�P' �4A.,Tj-.
��1:1�I'i 44'lE`R.F.- .��:� �'. S
� ,� �,. (\i�il.'_-S r�;i.
�.�\ \ /
;N;iEY��;d!`*Y i:.^iti.;ifLL JR \\.�
W1EEL��t!!�T wi fN?47kT � �`
d�TEYYf<,k EiJ1'kERT�-,.,\ �: :
��
(E P "t,ryU��FK �V.�:-^.�'CD�::AE SWr:L AL'GS G�IE
FEK"_E k��1.33:11ESH-,..
� %' �1�!� .•.�XFI':Llhl:FE�r.E
�� / ;i
� �� t ���
�-�..�n LEvEL �... Y ..2__�..3-.�-- �w T�i.�. ���� __ ;
p-r;
Elevation View
ViSIbZlZt1�
The COW is proposed to be located towards the rear of the existing Apple office
building, interior to the project site. While proposed at 60' tall, the COW will be
obstructed from view from the north, west, and east by trees, and another Apple office
building to the south.
Noise
No significant noise impacts are anticipated, provided that the equipment does not
generate noticeable noise or vibration and the closest residential use is located
approximately 800+feet away from the proposed equipment.
Duration
The facility is proposed for a period of one year while AT&T works on identifying and
permitting a new permanent cell site.
TUP-2013-04
19050 Pruneridge Avenue Temporary COW Page 4
FINDINGS
Prior to approval, the Community Development Director must make the following
findings as outlined in Section 19.160.030 of the City of Cupertino Municipal Code. Staff
analysis is shown below the required findings in italics.
A. The granting of the application will not be detrimental or Tnjurious to�roperty or
improvements in the vicinity, and will not be detrimental to tl2e pi�blic, health, safety,
general welfare, or convenience; and
As proposed, the temporary COW shall provide adequate protective barriers.
The plans will be required to be submitted as part of a building permit for review
for consistency with applicable code and safety requirements.
The temporary COW is proposed to mitigate any loss of cellular service in the
area while AT&T attempts to find a new permanent facility. Due to the
temporary nature of the use, no significant impact to public convenience is
anticipated.
B. The pro�osed use will be located and conducted in a manner in accord with the Cupertino
General Plan and the purposes of this title.
As conditioned, the project shall be conducted in a manner that serves the
General Plan Guiding Principals in that adequate safety measures have been
taken to mitigate potential impacts to people, property, and the environment.
The proposed location promotes attractive community design in that the facility
is temporary and not highly visible.
The facility has also been reviewed for consistently with the setback
requirements stipulated in the City of Cupertino Wireless Facilities Master Plan.
The facility meets the required setbacks being greater than 75 feet to any
residential property (closest is approximately 800+feet to the east).
ACTION
The Director of Community Development deems this application as minor, and
approves the temporary COW subject to the following conditions of approval.
1. APPROVED PROTECT
This approval is based on the plan set entitled "APPLE WORLD CAMPUS
COW" consisting of eight (8) sheets (T-1, A-1 through A-6, and E1), stamped as
TUP-2013-04
19050 Pruneridge Avenue Temporary COW Page 5
received August 27, 2013, except as may be amended by the following
conditions.
2. ACCURACY OF PROTECT PLANS
The applicant/property owner is responsible to verify all pertinent property data
including, but not limited to, property boundary locations, building setbacks,
property size, building square footage, any relevant easements and/or
construction records. Any misrepresentation of any project data may invalidate
this approval and require additional review.
3. DURATION
The temporary COW and all associated equipment shall be removed from the
site no later than September 12, 2014. A new Temporary Use Permit shall be
submitted to the City for review and approval prior to the Temporary Use
Permit expiration.
4. BUILDING PERMIT REQUIRED
Issuance of a building permit shall be required prior to installation of proposed
equipment and facilities.
5. GRADING AND CONSTRUCTION HOURS
All grading activities shall be limited to the dry season (April 15 to October 15).
Grading hours shall be limited to Monday through Friday, 7 a.m. to 8 p.m.
Grading, street construction, demolition or underground utility work shall not
occur on Saturdays, Sundays and holidays, and during the nighttime period as
defined in Section 10.48.053(b) of the Municipal Code. Construction activities
shall be limited to Monday through Friday, 7 a.m. to 8 p.m. and Saturday and
Sunday, 9 a.m. to 6 p.m. Construction activities are not allowed on holidays.
The developer shall be responsible for educating all contractors and
subcontractors of said construction restrictions. Rules and regulation pertaining
to all construction activities and limitations identified in this permit, along with
the name and telephone number of a developer appointed disturbance
coordinator, shall be posted in a prominent location at the entrance to the job site.
6. ANNOTATION OF THE CONDITIONS OF APPROVAL
The conditions set forth shall be attached to, incorporated into, or annotated on
the first page of the building plans.
7. NOISE
Noise shall not exceed the maximum Daytime and Nighttime exposure limits
TUP-2013-04
19050 Pruneridge Avenue Temporary COW Page 6
prescribed in Chapter 10.48 of the City of Cupertino Municipal Code.
8. CONSULATION WITH OTHER DEPARMENTS
The applicant is responsible to consult with other departments and/or agencies
with regard to the proposed project for additional conditions and requirements.
Any misrepresentation of any submitted data may invalidate an approval by the
Community Development Department.
9. NOTICE OF FEES, DEDICATIONS, RESERVATIONS OR OTHER EXACTIONS
The Conditions of Project Approval set forth herein may include certain fees,
dedication requirements, reservation requirements, and other exactions.
Pursuant to Government Code Section 66020(d) (1), these Conditions constitute
written notice of a statement of the amount of such fees, and a description of the
dedications, reservations, and other exactions. You are hereby further notified
that the 90-day approval period in wllich you may protest these fees, dedications,
reservations, and other exactions, pursuant to Government Code Section
66020(a), has begun. If you fail to file a protest within this 90-day period
complying with all of the requirements of Section 66020, you will be legally
barred from later challenging such exactions.
10. INDEMNIFICATION
To the extent permitted by law, the Applicant shall indemnify and hold harmless
the City, its City Council, its officers, employees and agents (the "indemnified
parties") from and against any claim, action, or proceeding brought by a third
party against the indemnified parties and the applicant to attack, set aside, or
void this ordinance or any permit or approval authorized hereby for the project,
including (without limitation) reimbursing the City its actual attorneys' fees and
costs incurred in defense of the litigation. The City may, in its sole discretion,
elect to defend any such action with attorneys of its choice.
This approval is granted on September 16, 2013. Please note that an appeal of this
decision can be made within 14 calendar days from the approval date. The fourteen
calendar day appeal period expires on September 30, 2013. If an appeal is filed, a public
hearing will be scheduled before the Planning Commission. If no appeal is filed, the
Director's Temporary Use Permit becomes effective on October 1, 2013.
Attachments
Attachment 1 - Plan Set
G:\PlamTing\PDREPORT\TUPreports\2013\TUP-2013-04.docx
,,,H ,-,���
,A��.,.
s;Y '���
f�f��N
�i
� ,.
�-, ���.
F/�h..
�,
�,� r;,.
,r��
APPLE WORLD CAIVIPUS COW
PROJECT DESCRIPTION
A(N) TEMPORARY UNMANNED MOBILE TELECOMMUNICATION FACILITY KNOWN AS A COW, "CELL ON WHEELS", CONSISTING OF(1) (N)23"RACK
W/(1)(N) 6601-DUL RBS UNIT, (3) (N) RRUS-11'S MOUNTED TO(N) MAST, A (N)LINEAGE DC POWER PLANT, A(N) BATTERY RACK, (6) (N)
ANTENNAS, (24) (N) RUNS OF COAX CABLE, &A(N) GPS ANTENNA WITHIN A(N)30'X30' LEASE AREA.
SI?E NAME:
COUNTY:
APN:
SITE ADDRESS:
CURRENT ZONING:
CONSTRUCTION TYPE:
OCCUPANCY TYPE:
PROPERTY OWNER:
APPUCANT:
LEASING CONTACT:
ZONING CONTACT:
CONSTRUCTION CONTACT
LATITUDE:
LONGITUDE:
AMSL:
PROJECT INFORMATION
AP?LE WORLD CAMPUS COW
SANTA CLARA
316-06-033
19050 PRUNERIDGE AVENUE
CUPERTINO, CA 95014
V-B
U, (UNMANNED COMMUNICATIONS FACILITY)
AT&T
4430 ROSEWOOD DR BLDG 3, 6TH FLOOR
PLEASANTON, CA 94588
ATTN: JASON OSBORNE
(415) 559-2121
ATTN: JASON OSBORNE
(415) 559-2121
ATTN: MARK CONWAY
(510) 206-1463
N 37'19' S2.8" NAD 83
W-122'00' 27.3" NAD 83
f 162'
SITE #: CCU2693 /CCL02593
JURISDICTION: CITY OF CUPERTINO
POWER: PG&E
TELEPHONE: AT&T
VICINITY MAP
DRIVI NG DI RECT��NS
FROM: 4430 ROSEWOOD DR BLDG 3, 6TH FLOOR, PLEASANTON, CE�94588
T0: 19050 PRUNERIDGE AVENUE, CUPERTINO, CA
1. HEAD EAST ON ROSEWOOD DR 20 FT
2. MAKE A U-TURN 0.5 MI
3. TURN RIGHT ONTO OWENS DR 0.2 MI
4. TURN RIGHT ONTO HACIENDA DR 0.3 MI
5. SLIGHT RIGHT TO MERGE ONTO I-580 W TOWARD OAKLAND 1.8 MI
6. TAKE THE EXIT TOWARD SAN JOSE 0.8 MI
7. MERGE ONTO I-680 S 16.6 MI
8. TAKE THE MISSION BLVD/STATE ROUTE 262 EXIT TOWARD I-88C; 0.2 MI
9. KEEP RIGHT AT THE FORK, FOLLW SIGNS FOR MISSION BLVD W F,ND MERGE ONTO
STATE ROUTE 262 EXIT TOWARD I-880 0.9 MI
10. KEEP LEFT AT THE FORK, FOLLOW SIGNS FOR INTERSTATE 880 S/SAN JOSE
AND MERGE ONTO I-880 S 12.6 MI
11. TAKE THE EXIT ONTO I-280 N TOWARD SAN FRANCISCO 4.3 MI
12. TAKE THE WOLFE ROAD EXIT 0.4 MI
13. TURN RIGHT ONTO N WOLFE RD 0.1 MI
14. TAKE THE 1ST RIGHT ONTO PRUNERIDGE AVE 0.4 MI
END AT: 19050 PRUNERIDGE AVENUE, CUPERTINO, CA
ESTIMATED TIME: 42 MINUTES ESTIMATED DISTANCE: 39.1 MILES
.+�"°.��i,3��4�
. ', , .
- .�t-�� ,.�
- , . .,t ,
.,.. ... .. . > .y_ . . . .,,. ,, " . _
CODE COMPLIANCE
ALL WORK & MATERIALS SHALL BE PERFORMED &INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING
CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK
NOT CONFORMING TO THESE CODES:
t. 2010 CALIFORNIA ADMINISTRATIVE CODE (INCL TITLES 24 & 25)
2. 2010 CALIFORNIA BUILDING CODE
3. 2010 CALIFORNIA ELECTRICAL CODE
4. 2010 CALIFORNIA MECHANICAL CODE �
5. 2010 CALIFORNIA PLUMBING CODE D JGL' � LJ U �j
6. 2010 CALIFORNIA FIRE CODE
7. LOCAL BUILDING CODES ^"�1 ,G ( 20��
8. CITY/COUNTY ORDINANCES
9. ANSI/EIA-TIA-222-G �
ALONG WITH ANY OTHER APPLICABLE LOCAL&STATE LAWS AND REGULATIONS
DISAB�ED ACCESS REQUIREMENTS
THIS FACILITY IS UNMANNED &NOT FOR HUMAN HABITATION. DISABLED ACCESS& REQUIREMENTS ARE NOT REQUIRED IN
ACCORDANCE WITH CALIFORNIA STATE BUILDING CODE TITLE 24 PART 2, SECTION 11346.2.1, EXCEPTION 4
SHEET
T-1
A-1
�-2
A-3
A-4
A-5
A-6
E-1
SHEET INDEX
DESCRIPTION
TITLE SHEET
SITE PLAN
tNLAR�tG SiTt PLHiv
ELEVATIONS
DETAILS
DETAIL
DETAILS
ELECTRICAL PLAN
APPROVAL
RF
LEASING
ZONING
CONSTRUCTION
AT&T
APPLE WORLD
CAMPUS COW
CCU2693/CCL02693
190�0 PRUNERIDC;E AVE
CUPERTINO.CA 9i014
ISSUE STATUS
Q DATE DESCRIPTION BY
08 12 13 CD 90� A.G.
DRAWN BY: A. GOLESORKHI
CHECKED BY: C. MATHISEN
APPROVED BY: -
DATE: 08/12/13
wo�
� n v "��"
:• rn o o' o;¢
-,�:. U o c�0 °�oy�
. ���
� m�,� -
�a�r � �o
�w' �-�� C� x p
� ��' � � E =z
ei.1 w L ° _°�
::
a ° �ow
"_ �� c c I a
� �' � �; � wo>�
���
I V`"� m o � �0°8
0.1'i cn �gN
� � �' ��ms
Cr. • � �>� = -
� ^ U�> �,;��
�r. �� m� uY, �
�'�i• '� � � ° _
�.... � -
y�� � v U�
ao
t'r'� � a w
�
�, w��
w��w
� >
� �
�
�
x
�
�
� �
J�m
��
O V
�z
O
,`���`°'�� O Q
3� ?�y. �N
;;�,� �,°,u�
� -�,� �a
,-
�,",.� �,�
SHEET TITLE:
TI T�E
SHEET NUMBER:
T-1
PROJECT GENERA� NOTES
t. THIS FACILITY IS AN UNOCCUPIED WIRELESS TELECOMMUNICATION
FACI LI TY.
2. PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A
DIAGRAMMATIC OUTLINE ONLY, UNLESS NOTED OTHERWISE.
3. THE SCOPE OF WORK SHALL INCLUDE FURNISHWG MATERIALS,
EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE
ALL INSTALLATIONS AS INDICATED ON THE ORAWINGS.
4. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS SHALL
VISIT THE JOB SITE AND BE RESPONSIBLE FOR ALL CONTRACT
DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS, AND CONFIRM
THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO
PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES ARE TO BE
BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER AND
ENGINEER PRIOR TO PROCEEDING WITH THE WORK.
5. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PAY FOR
PERMIT FEES, AND TO OBTAIN SAID PERMITS AND TO COORDINATE
INSPECTIONS.
6. THE CONTRACTOR SHALL RECEIVE, IN WRITING, AUTHORIZATION TO
PROCEED BEFORE STARTING WORK ON ANY ITEM NOT CLEARLY
DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS.
7. CALL BEFORE YOU DIG. CONTRACTOR IS REQUIRED TO CALL 811
(NATIONWIDE "CALL BEFORE YOU DIG" HOTLINE) AT LEAST 72
HOURS BEFORE DIGGING.
8. ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN
STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS,
AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND
COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND
LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE
PERFORMANCE OF THE WORK.
9. THE GENERAL CONTRACTOR SHALL SUPERVISE AND DIRECT THE
WORK USING THE BEST SKILLS AND ATTENTION. THE CONTRACTOR
SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS,
METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES.
CONTRACTOR SHALL ALSO COORDINATE ALL PORTIONS OF THE
WORK UNDER THE CONTRACT; INCLUDING CONTACT AND
COORDINATION WITH THE CONSTRUCTION MANAGER AND WITH THE
LANDLORD'S AUTHORIZED REPRESENTATIVE.
10. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO
PROTECT EXISTING IMPROVEMENTS, PAVING, CURBS, GALVANIZED
SURFACES, ETC., AND UPON COMPLETION OF WORK, REPAIR ANY
DAMAGE THAT OCCURRED DURING CONSTRUCTION TC TNE
SATISFACTION OF THE PROJECT MANAGER.
11. KEEP GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL
DIRT, DEBRIS AND RUBBISH. REMOVE EQUIPMENT NOT SPECIFIED AS
REMAINING ON THE PROPERTY. LEAVE PREMISES IN CLEAN
CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF
ANY NATURE.
12. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER
UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK,
SHALL BE REMOVED AND/OR CAPPED, PLUGGED, OR OTHERWISE
DISCONNECTED AT POINTS WHICH WILL NOT INTERFERE WITH THE
EXECUTION OF THE WORK, AS DIRECTED BY THE RESPONSIBLE
ENGINEER, AND SUBJECT TO THE APPROVAL OF THE OWNER
AND/OR LOCAL UTILITIES.
13. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND ALL
OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK SHALL BE
PROTECTED AT ALL TIMES.
14. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR
MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR
CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS
PART OF THE WORK.
15. THE CONTRACTOR SHALL PROVIDE A TOILET FACILITY DURING ALL
PHASES OF CONSTRUCTION.
16. SUFFICIENT MONUMENTATION WAS NOT RECOVERED TO ESTABLISH
THE POSITION OF THE BOUNDARY LINES SHOWN HEREON. THE
BOUNDARY REPRESENTED ON THIS MAP IS BASED ON COMPILED
RECORD DATA AND BEST FIT ONTO EXISTWG IMPROVEMENTS. IT 15
POSSIBLE FOR THE LOCATION OF THE SUBJECT PROPERTY TO SHIFT
FROM THE PLACEMENT SHOWN HEREON WITH ADDITIONAL FIELD
WORK AND RESEARCH. THEREFORE ANY SPATIAL REFERENCE MADE
OR SHOWN BETWEEN THE RELATIONSHIP OF THE BOUNDARY LINES
SHOWN HEREON AND EXISTING GROUND FEATURES, EASEMENTS OR
LEASE AREA IS INTENDED TO BE APPROXIMATE AND IS SUBJECT TO
VERIfICATION BY RESOLVING THE POSITION OF THE BOUNDARY
LINES.
17. THE CONTRACTOR TO VERIfY THE LATEST/CURRENT RF DESIGN.
18. WHERE APPLICABLE, CONTRACTOR SHALL PROVIDE SEPARATE
P�ANS, SPECIFICATIONS, FEES AND PERMITS fOR ANY REVISION TO
ANY FIRE SPRINKLER AND/OR ALARM SYSTEM ON THE PREMISES AS
MAY BE NEEDED TO COMPLETE THE WORK DEPICTED HEREIN, USING
A C-10 LICENSED SUBCONTRACTOR FOR ALL SUCH WORK.
(E)SITE ACCESS
�
�(E) ASPHALT PARKING LOT
Y
(N) 30'-0"X30'-0"
AT&T LEASE AREA W/
(N) CHAIN LINK FENCE
(E) PULLBOX W/AT&T POWER P.O.C.
(E) PULLBOX W/AT&T TELCO P.O.C.
'�] �
�
i�i� �
�,,.,.
;
���.
%
(E)BUILDWG ;� (E)BUILDING
�;,, ,;
E���G�
P�v�
� I� �
I
' II /
I� i�__
I Y�� �
(E) ASPHALT PARKING LOT�
— � I —�I I—
� I
� � ; �
�
10'-0" SITE � � I_
ACCESS ROUTE � I_
— � �
� I �
� I I (E) UTILITY
— �i � —� TRENCHING FOR
' —�I FIBER & POWER—
z - II I - I-
>- � i I
� i � — �—�
a � � � i�
a � � � I_ II
- � �I � I I�
� Ii
P��
\
�""�(.���,;?�1�-���
. . � . _. _ ._r:i� .. . .
L.�.� , �. � .. . .�• ..._ - ._... ... �,. . ... ,.-.
� � • . • � � ,' ... 4 ' . ' ,
- �I �� � �� � SEE SITE P�AN �'�
— I � — — �I �-
� � i
I_ �I �
I
� � lil
� - � (N) TEMPORARY C.O.W. (CELL
_ _���_=ON WHEELS) UNIT W/(N) AT&T
_- �. ANTFNNAC,� F!)IIIP�IFNT
(E) CONSTRUCTION
SITE ACCESS GATE #4
�
�
(E)CONSTRUCTION SITE J
(E) 8'-0" TALL CHAIN LINK
FENCE W/BLACK MESH
(E)ASPHALT PARKING LOT
�
(E) ASPHALT PARKING LOT
S TE P�AN
�r�
1"=40'-0"
0 20' ao' so' �20' zoo'
z
�
z
�
C
C
r�
�, I,
�
NOTICE
PROPOSED ANTENNA MAST TO BE ANALYZED BY
MANUFACTURER. STREAMLINE ENGINEERING &DESIGN
INC. IS NOT RESPONSIBLE FOR THE EVALUATION OF
THE PROPOSED COW OR ANTENNA MAST.
APPLE WORLD
CAMPUS COW
CCU2693/CCL02693
190�0 PRUNERIDGE AVE
CUPERTINO.CA 95014
ISSUE STATUS
Q DATE DESCRIPTION BY
08 12 13 CD 90% A.G.
DRAWN BY: A. GOLESORKHI
CHECKED BY: C. MATHISEN
APPROVED BY: —
DATE: 08/12/13
� � �goN
� �M� 003¢
vr'�°c osw`
o`° w¢=
�� �CO� ��''"
� ' m`O� o�o
�. �� c
. � N �foa
� LL =p
�� � �
�ii �%. W L U �i
y a �ow
•�r �' '3 C C w3wz
� tn N a�i �°T<
��� =
� ow
� m o� o�§
C'i� a�� � ��ms
.'� N.�N �o�,
C �Y ' z3N8
�/�, ; U i
_V ��Y .�
`v.7 � °� � " i
"ir�":" �U� oaa
C'�"S . w �
�� � ��z
�,: N��=
r 3
� �
�
H
cc
cri
� �
J�m
0�
O V
�z
O
-�i"�'�"�a, �N
�,� ��
s';4 �
ry,� a
�`�a ;:��
SHEET TITLE:
SI TE PLAN
SHEET NUMBER:
A-1
I I
� I
(N) 30'-0"X30'-0" AT&T LEASE AREA
WJ(N) 6'-0"CHAIN LINK FENCE--
(N) TEMPORARY C.O.W. (CELL ON WHEELS)
UNIT W/(N) AT&T ANTENNAS&EQUIPMENT-
�
,� ---- ------ , ---30'-0"-- � - �
I i I �� �i
—d—0—a—0�—� —��—O �—0�—O�—�--0--0----0 i
�
� �, �
(E� CONCRETE CURB� TYP �' I/f"���'u3!����'M/�.��'J/„��rfiirf���✓�xifr"�,z7�'/a�l�/,,��/�,�',�"�/,; �u�;nk��z�ra""���;�%�v';� I
�
�
q � � ___--� � i
I � �—(E)PARKING STRIPE, TYP I
qqq � I
I (N) 02" CONDUIT FOR POWER�
� �, ���� �
(E) PULLBOX W/AT&T POWER P.O.C.� � I '� �o�Gy � �(N)REMOVABLE TONGUE
�
�
�
I
(E)PULLBOX W/AT&T TEL.,.,,..,..,. �
�
(N)02"CONDUIT FOR TELCO �
r, T
9 ��, (N) GPS ANTENNA �
`��s:
P P P P P P
----- ------ ------------- -----
4'-4" (N) METER
�
�BI(N) MAST W�(3) (N) FIB/P F�/ `P FIB/P FIB/P FI /P
AT&T ANTENNAS&
� (1) (N)RRUS-11
�---- -- ----�--- - - --------------�
; (N) 2" CONDUIT FOR��,�Y%�'�',.- ' .,,�?�,. o e � e
FIBER &DC POWER / -o a _ � AZIMUTH = 90'�
SECTOR C
���
T T P,�������0-T
I S�G'�
i
(N) 23" RACK W/(1)
(N) 6601-DUL UNIT—�
(N) 26"
BATTERY RACK
�I
���;,'�,
(N) 26" LINEAGE
POWER RACK
I
(N) OUTRIGGER, TYP OF 4
�3'—s° ,
�
�
�
�—o--��--0�-0
(N) ACCESS DOOR, TYP OF 2
' � NOTE: ALL(N)EQUIPMENT CABINETS
I &EQUIPMENT RACKS TO BE INSTALLED
W/ELECTRICAL ISOLATION PAD
�i
i
NOTICE
PROPOSED ANTENNA MAST TO BE ANALYZED BY
MANUFACTURER. STREAMLINE ENGINEERING&DESIGN
INC. IS NOT RESPONSIBLE FOR THE EVALUATION OF
THE PROPOSED COW OR ANTENNA MAST.
I
6 t� -�
� -�Z�6 4,.
�
0 4"
_�6
_. B
B
2'-4"
,�—�� �
�
�� I (N) I � (N) I I
�I HVAC / � HVAC I �
' / \ I
�---- � i � � ---J
II i � li
�� �� II
_� ��—_JJ
4'-6"
(E) 8'-0" TALL CHAW LINK FENCE W/BLACK MESH-
_ � �
_ >
(N)MAST W/(3)(N) ____30'-0"/
AT&T ANTENNAS & �i�
(2) (N)RRUS-11'S �
I
(24) (N) RUNS OF COAX p
CABLE /
(N) 3206 RBS!'ABINET
�
(N) 3206 RBS CABINET P
�
O
\N) 3206 RBS CABINET
�
�
�
�
EN�ARGED S TE P�AN
.,.�
,"=s'—o„
0 1' 2' 3' 4' S' 10' 15' 25'
(N) GUY WIRE,
TYP OF 8
i
� �
�i 'i
I i
I ,
' 10'-0" SITE
� ACCESS ROUTE �
I
i
I I
` �i
(N) 12'-0" DOUBLE
SWING ACCESS GATE
FIB/P FIB/P FIB/P
FIB/P FIB/P FIB/P
APPLE WORLD
CAMPUS COW
CCU2693/CCL02693
190�0 PRUNERIDGE AVE
CUPERTINO.CA 95014
ISSUE STATUS
p DATE DESCRIPTION BY
08 12 13 CD 90� A.G.
DRAWN BY: A. GOLESORKHI
CHECKED BY: C. MATHISEN
APPROVED BY: -
DATE: 08/12/13
--------------------T----------------------------- � � �_=o� �
� a "g��
0
�; �°� �o;�
U°'c°o ��w`
� a� wo�
m�°�° �w'�
e.'�".'.`,'1��� m�� `<�'
„�„'- X w�°o
(E)UTILITY TRENCHING �C`� �� . 6, � ��oa
FOR FIBER & POWER ��� � �;E Q =�
c ww
� , W L O a=°�
�� U U�w
•�*�. ' •� c c w3w�
�`.a cn °�,' � Q�=<
'1��,�G'--�,��i�"L�'7 ""'i-� >o� �ooN
. . - . � �, � a� �_ws
m�
: ,. �� - � .�> ,�..�... ��., a��i��N �a°
_ � � -��-1� �.. � @Y� N;N
�Y p u z i
.: •. �. I � � �o.� `s�<w
1 � ,. t ,V �r.� y': :� i .*.,,�"'�" � V U� z N
. .,� .._ � � � w ��s�^��
� sz�V
;� �z
APN: 316-06-033
(E) CONSTRUCTION SITE ACCESS GATE #4
� ��
II
��
I1
I 1 — �— —
• �—� -- -- —
i \
/ \
/ �
/ \
� �
i �
i �
i �
i �
i �
� / �
i �
� �
� �
� �
� �
, ,
, ,
, ,
, ,
� �
� �
�__---��� \���----_J
� ���:
a` �
� �
O
�
H
cc
c�i
� �
m�
�
�
�U
O
�O
�Z
'��'�w„°�;�A O Q
�;�4h ��
' 9� �u�
�u i; J
• y a
�,.,�-.���
SHEET TITLE:
EN�ARGED SITE P�AN
SHEET NUMBER:
A-2
(N)ANTENNA PUCK &PLATE W/
ANTENNA MOUNTING POLE PER
nn.�.n.in rn�nrn-i nv riir.i uirrr
NORTH E�E�AT ON
�°=�'-o„
� TOP OF(N) AT&T ANTENNAS
t55'-0" A.G.L.
� TOP OF(N) ANTENNA MAST
t54'-11° A.G.L.
� RAD CENTER OF(N) AT&T ANTENNAS
f52'-11" A.G.L.
GROUND LEVE�
0'-0"
(N) TEMPORARY C.O.W.
WHEELS) UNIT W/
ANTENNAS &E�
(E) 8'-0"CHAIN LI
FENCE W/BLACK ME
i r.��_.;��i3—��i
, . . � �Y
. �,� � . .�.
�-1�� '
. . �
. . . ,� . _..�
� . •- � , �
EAST E�E�ATON
�°=,'-o„
APPLE WORLD
CAMPUS COW
CCU2693/CCL02693
190�0 PRUNERIDGE AVE
CUPERTINO,CA 95014
ISSUE STATUS
Q DATE DESCRIPTION BY
08 12 13 CD 90� A.G.
DRAWN BY: A. GOLESORKHI
CHECKED BY: C. MATHISEN
APPROVED BY: —
DATE: 08/12/13
�o�
�c e=°w
� � � oN
og�
6��� 0 3¢
U o� �o�
@�� �
t""i��� m�� �`�"
� �o�o
.� �: .��, m ��a
�..� , c� �� < ��
�.'Z� : C� oE ww
t7.'s w L ° ���
�a • °pw
.� .� � � w�a�
� � � � N�ya
��� �
> �wm
`'`"' m o� .���
ci� u�� � ��ms
.C, � a� ' `n �zr
��+..rri o Y c Q w<�
` : U� > �iNw
-_ ��:.� m@ Y o�i i
Q� � � p.� �baw
� y; ��� gao
� w �"_�
�,. a==�
� N�°z
� �
�
�
E �
cc
ri
� �
J�m
0�
O V
�O
�
�..��,, O�
u �NQ
��% �W
�• °' �J
°d';� �a
SHEET TITLE:
E�EVATIONS
SHEET NUMBER:
A-3
POWERWAVE
P65-15—XLH—RR
(s.o")
I I
(12.0")
,� 'r'
i
�
�
LEFT VIEW FRONT VIEW
� A TE f�A D E TA
Y2=1-0"
;��`��
,�
I�
ISO �IEW
MOUNTING HARDWARE
(VARIES)
02�" O.D. GALV
STD PIPE
PANEL ANTENNA
(VARIES)
(1;
SIDE VIEW
2 A TE A MOU T DETA
1 =1-0
��26.�����
TOP VIEW
(22.3")
(2�.5")
�� T-�-
a
�
��~��fl9 +'�
���
r_-
.--�
_,� �
�� �.
(84.0") �,�,_�
FRONT VIEW
(10.0")
(5.0")
�o:,
�
,`^ _^�{
�
��'-'� LINEAGE POWER 26" RACK
- �l', #CC848828938
� -
(6.1")-1
�
,�(i5.o)
SIDE VIEW
DC POWER 26" RACK DETA �
6 y.,=,�-o„
�(17.8)�
T(1 D \/I C 1�1 ERICSSON
RRUS-11
;7.2")
�
FRONT VIEW RIGHT VIEUV
,3 RRUS- 11 DETA !_
1 =1.-0 WEIGHT- 50LBS
�(26.�"/�
TOP VIEW
(22.3")
�z�.5")
��
(84.0") ,�- � �I
�
`^^^^
� _r,_
FRONT VIEW
i
�,�Q�
4 GPS DETA
3=1-0"
(10.0")
�5.0°�
LINEAGE POWER 26" RACK
#CC848828938
�-- MARATHON 12V155FT
lf BATTERY, TYP
�'_ -�
_
u-- --
�6.���� ` I_ — '..
�
,��,5.0)
SIDE VIEW
26" BATTERY RACK DETA �
7 y,._,'-o.,
0.750 HOLE, TYP 4 PLACES
�-�
(15.0) ;..:....a....:..� (10.5)
,�L=7 tl
I (22.8) I
,�-(27.5) �
MOUNT W/(4) MOUNTING TOP VIEW
SCREWS CHATSWORTH PART#
13855-703 OR EQUIVALENT - �
�
(N) 6601-RBS EQUIPMENT i � i
� �
12-24, THD MTG HOLES E I
135 PLS(45 RMU) � (84.0)
SIDE VIEW
' 0.656 HOLE,
�i-'o TYP 12 PLACES
(23.0) O
� 0
� O
(39.0) O
oo,
(4A�. ..
�
FRONT VIEW
APPLE WORLD
CAMPUS COW
CCU2693/CCL02693
19050 PRUNERIDGE AVE
CUPERT[NO.CA 9�014
ISSUE STATUS
p DATE DESCRIPTION BY
08 12 13 CD 90% A.G.
DRAWN BY: A. GOLESORKHI
CHECKED BY: C. MATHISEN
APPROVED BY: -
DATE: 08/12/13
^ � Noo�
� � o =
�o �o;�
" RA,CK W 6601 DETA � U�� pVwa
23 SE SM C / °`� np°�
��� _ ��
5 ��� °°�°' �ooa
,.�. X
Y2�=�_�" ��� �� �C rn �p ����
� �� � �' � = ww
�
w= � _�_
C"�; � a' �
` � �ow
•��„r,.,�._.i:: .� c c w.3 w z
��� � u�i N N°i�
�� C a
�
�.+�.... : m �� ��w g
Q� a�� �' ��ms
�� � � 1 N ��S
-����' 0 Y �
�/�, w f6 U � ���w
_V e�+Y f U�u
� �i. � 0— �y u
� � � LLn
�`�"'1 � ��� =a o
`� W �=�w
�
�, N� �
a��z
� Ww��
�: �
•1"'u,�':.-��1�'-�"r-f'
_ ' : � . �G��J' - � . `-��:
... .. �.....r�`�. _.
� � ' � :4
�(23.6')�
(15.8")
�
ERICSSON
RBS 3206
TOP VIEW
�
I
i
(79.8") '
i I
I
�RONT VIEW RIGHT VIEW
8 RBS DETA �
YZ=1—0" WEIGHT = 441 LBS
� �
�
�
�
co
c�i
� �
J�
m
�
�
�U
O
�z
O
"�,�;."�,�,
z
��,�����¢ �j J
' ., , � �a
-=�.�,��
SHEET TITLE:
DETAI�S
SHEET NUMBER:
A-4
OUTRIGGERS FRuNl
(EXTENDED), �
OUTRIGGER JAC
���'����-� -��'
�i-��� 13.._ .
�.,,.�„��,,.,,. �, , .,.,", .,,.,,
BACK VIEW
,y„� �t3'-
,�- -- ---- �,o�—,o°�
I
60' MAST, TYP OF 2
TRANSFER SWITCH
REMOVABLE TONG�JE
,�— (7�-3°)
V A/C UNIT
�
N A/C UNIT
C�O�W� (CE�� ON '�UHEE�S) DETA �
1 y„_,'-o" - - - -- --- -
SIDE VIEW
APPLE WORLD
CAMPUS COW
CCU2693/CCL02693 I
190�0 PRUNERIDGE AVE
CUPERTINO.CA 95014
�
ISSUE STATUS
p DATE DESCRIPTION BY
08 12 13 CD 90% A.G.
DRAWN BY: A. GOLESORKHI
CHECKED BY: C. MATHISEN
APPROVED BY: -
DATE: 08/12/13
�o�
�o a�°p
' � V �io:
� � � ��
��M� a°o�¢
- a�C�O o5w`
���:. U�cG a w'o�
�x ��� z¢R
`i1'1 ws [��o� a��
� s. y� Eo`
�w y ��� .0� @ ��oi
� �i � °'� �p
c
ti� w r ° �°�
� �� V uow
•�r s �j C C w3w3
_ �� � N N Noia
'� y C w
`�`'�•� ) owmw
W - m 0 � zow8
��::'�.._.�: � a
� � �' �=ms
c"";: � �'�� :���
"+� o Y c N-�s'
�r U��> �>�w
� � �y o;zi
� � N C_ c`i�<w
4.... ,� �c.� f6 " :
� ,- � � d aa
z, � w o
� ��_�
� sz�z
�
y�� ww��
�'_ �3
' OF2 � a'
�
�
_
�
co
M
� �
J�m
0�
p U
�O
�
�'"�;"'� �N
�����,,
/ � y� 4
7.;''y. W
?�, �J
1/ y.';a;/�� d
�
SHEET TITLE:
DETAI�
SHEET NUMBER:
A-5
�❑
�
IN A E OF
CS
EMERGENCY
CALL
- - 2-6662
1 800 83
Site No: CCU2693
�
�
�
i
Beyond This Point you�e
entering an area where radio
frequency emissions may exceed
the FCC General Population
Exposure Limits.
Follaw all posted signs and site guidelines far
working in a radio frequcncy environment.
Ref FCC 47C,FR 1.130?(b) Cingular Wireless
T�'r CA� CAU T ON S GN 2 TYP CA� CAU T O�J S �N
1
CONSTRUCTION NOTES
1. EXISTING BUILDING CONSTRUCTION CONDITIONS INDICATED ON THE DRAWINGS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO
PROCEEDING WITH CONSTRUCTION OR ORDERING OF MATERIALS. IF EXISTING CONDITIONS DO NOT ALLOW FOR DETAILS OF CONSTRUCTION AS
SHOWN ON THESE DRAWINGS, NOTIFY ENGINEER OF RECORD FOR RESOLUTION PRIOR TO PROCEEDING. CONTRACTOR SHALL EXPOSE AND REVIEW
EXISTING CONDITIONS IN A TIMELY MANNER SUCH THAT ALTERNATE DESIGNS OR DETAILS, IF REQUIRED MAY BE GENERATED WITHOUT DELAY TO
THE PROJECT.
2. D U R I N G C O N S T R U C T I O N, T H E C O N T R A C T O R S H A L L N O T A L T E R, D A M AG E O R R E M O V E A N Y P A R T O F T H E E X I S T I N G S T R U C T U R E U N L E S S
SPECIFICALLY DETAILED ON THESE DRAWINGS.
3. THE INTENT OF THESE DRAWINGS IS THAT THE WORK OF THE ADDITION, ALTERATION, REHABILITATION, OR RECONSTRUCTION IS TO BE IN
ACCORDANCE WITH THE 2010 CBC. SHOULD ANY EXISTING CONDITIONS SUCH AS DETERIORATION OR NONCOMPLYING CONSTRUCTION BE
DISCOVERED WHICH IS NOT COVERED BY THE CONTRACT DOCUMENTS WHEREIN THE FINISHED WORK WILL NOT COMPLY WITH THE 2010 CBC, A
CHANGE ORDER, OR A SEPARATE SET OF PLANS AND SPECIFICATIONS, DETAILING AND SPECIFYING THE REQUIRED WORK SHALL BE PREPARED
AND SUBMITTED TO AND APPROVED BY THE BUILDING DEPARTMENT PRIOR TO PROCEEDING WITH THE WORK.
4. ALL WORK AND MATERIALS SHOWN ARE NEW UNLESS INDICATED AS EXISTING(E).
5. IT MAY BE NECESSARY TO REMOVE ARCHITECTURAL FINISHES, PLUMBING PIPES AND FIXTURES, ELECTRICAL CONDUIT, FIXTURES, PANELS, BOXES,
TELEPHONE OR FIRE ALARM WIRING AND FIXTURES OR OTHER NON-STRUCTURAL ITEMS TO INSTALL STRUCTURAL WORK AND MATERIALS SHOWN
ON THESE DRAWINGS. SUCH ITEMS SHALL BE REMOVED, REPAIRED AND/OR REPLACED TO MATCH PRE-CONSTRUCTION CONDITIONS AT THE
CONTRACTORS EXPENSE.
6. ALL WEATHER PROOFING. INCLUDING BUT NOT LIMITED TO TORCH DOWN, CAULKING, Z-FLASHING OR ANY OTHER MATERIAL THAT MAY BE
ALTERED DURING INSTALLATION SHALL BE REPAIRED REPLACED AND/OR MODIFIED TO ENSURE THE BUILDING AT THE INSTALLATION SITE IS
WEATHER PROOF.
7. ANY PROPOSED SUBSTITUTIONS FOR STRUCTURAL MEMBERS, HARDWARE, ANCHOR TYPES, OR DETAILING INDICATED IN THESE DRAWINGS SHALL
BE SUBMITTED TO AND REVIEWED BY THE ENGINEER OF RECORD PRIOR TO ORDERING MATERIALS. SUCH REVIEW SHALL BE BILLED ON A TIME
AND MATERIALS BASIS TO THE CONTRACTOR WITH NO GUARANTEE THAT THE SUBSTITUTION WILL BE ALLOWED.
�XTERIOR SIDE FACILITY SIDE
IVACY SLATS PRIVACY
,',',``':
� ��
6,I�„
��/„
' �I
I ''
3'-0"2�_9�� I �
II I, ',
��
�
��—
,� � �,
3 012°,�-
02%" ASTM A53 SCHED
40 GALV POST TYPICAL
�2 T!NNED COPPEP,
CADWELD TO CORNER,
GATE, TERMINAL, OR
PULL POST TIED TO
GROUND RING TYP.
GROUND RING
CORNER POST DETA �
3 __ _- --- ____ _ __--
Y��-,�-o��
6'-0" ,
� �, CHAIN LINK
�FABRIC
�%r� �
�
i :,
3,I p..2'-9" ��
��
�
. ,
3°J '
-�'012"�
CHAIN �INK FENCE NOTES
1. INSTALL FENCING PER ASTM F567 AND F1083, SWIN�GATES
PER ASTM F900
2. GATE, CORNER, TERMINAL OR PULL POSTS SHALL BE 02%"
SCHED 40 FOR GATE WIDTHS UP TO 6 FEET OR 12 FEET FOR
DOUBLE SWING GATE.
3. LWE P O S T S SHALL B E 0 2%a' S CH E D 4 0 P I P E.
4. GATE FRAMES SHALL BE 1Y2° SCHED 40 PIPE.
5. TOP AND BRACE RAILS SHALL BE 01Ye" SCHED 40 F'IPE.
6. FABRIC SHALL BE 12 GAUGE CORE WIRE SIZE 2"MESH,
CONFORMING TO ASTM A392 CLASS 1.
7. ALL FENCING SHALL BE GALVANIZED STEEL.
8. TIE WIRE SHALL BE 11 GAUGE MIN. INSTALL A SINGLE WRAP
TIE WIRE AT POSTS AND RAILS AT MAX. 24" MAX IPJTERVALS.
INSTALL HOG RINGS ON TENSION WIRE AT 24" INTEPVALS.
9. TENSION WIRE SHALL BE 7 GAUGE.
10. GATE LATCH SHALL BE 01�" O.D. PLUNGER ROD W,�
MUSHROOM TYPE CATCH AND LOCK.
11. BARBED WIRE (IF USED) SHALL BE DOUBLE STRAND 12 GAUGE
TWISTED WIRE TO MATCH WITH FABRIC, 4 PT. BARBS SPACED
ON APPROXIMATELY 5" CENTERS.
�� ���.��;:
� '` 02%" ASTM A53 SCHED
�! 40 GALV POST TYPICAL
'�I � �
�I I�.���
: :r:i
,,
BOTTOM
TENSION WIRE
GROUND RING
I�I�
j;
"
���'
- � NE POST DETA �
_ _- --------- ---- --_--
4 Y2�=,�-o„
PRIVACY SLATS
GATE GROUNDING STRAP
#:? TINNED COPPER
CADWELD TO CORNER, GATE,
TERMINAL, OR PULL POST
TIED TO G�OUND RING TYP.
CIAGONAL ROD W/
S�EEL TURNBUCKLE
ALPHA SECTOR
BETA SECTOR
GAMMA SECTOR
ANTENNA & CABLE SCHEDULE
ANTENNAS
ANTENNA ANTENNA MODEL RAD CENTER AZIMUTH
POSI TION
A1 P65-15-XLH-RR 52'-11" 335'
A2 P65-15-XLH-RR 52�-11" 335'
Bt P65-15-XLH-RR 52'-11" 235'
62 P65-15-XLH-RR 52'-11" 235'
C1 P65-15-XLH-RR 52'-11" 90'
C2 P65-15-XLH-RR 52'-11" 90'
NOTE: CONTRACTOR TO VERIFY LATEST RF DESIGN
TMA OR DIPLEXER
NO
NO
NO
NO
NO
NO
CABLING
N0.OF COAX DIA. COAX
COAX CABLES LENGTH
4 �" 70'
4 i�" 70'
4 �" 70'
4 �" 70'
4 �" 70'
4 �" 70'
NORTHERN CALIFORNIA ANTENNA COLOR CODE
SECTORS A, B, & C
1900 GSM
TX 1/RX 1 RX 2 TX 3/RX 3 RX 4 TX 5/RX 5 RX 6
ALPHA UMTS 1900 4 BROWN 4 ORANGE 4 BRN/1 RED 4 ORN/1 RED 4 BRN/2 RED 4 ORN/2 RED
TX 1/RX 1 RX 2 TX 3/RX 3 RX 4 TX 5/RX 5 RX 6
ALPHA UMTS 850 5 BROWN 5 ORANGE S BRN/1 RED 5 ORN/1 RED 5 BRN/2 RED 5 ORN/2 RED
TX 1/RX 1 TX 2/RX 2 TX 3/RX 3 TX 4/RX 4 TX 5/RX 5 TX 6/RX 6
ALPHA LTE 700 6 BROWN 6 ORANGE 6 BRN/1 RED 6 ORN/1 RED 6 BRN/2 RED 6 ORN/2 RED
TX 1/RX 1 TX 2/RX 2 TX 3/RX 3 TX 4/RX 4 TX 5/RX 5 TX 6/RX 6
ALPHA LTE 1700/2100 � gROWN 7 ORANGE 7 BRN/1 RED 7 ORN/1 RED 7 BRN/2 RED 7 ORN/2 RED
TX 1/RX 1 RX 2 TX 3/RX 3 RX 4 TX 5/RX 5 RX 6
BETA UMTS 1900 4 YELLOW 4 BLUE 4 YEL/1 RED 4 BLU/1 RED 4 YEL/2 RED 4 BLU/2 RED
TX 1/RX 1 RX 2 TX 3/RX 3 RX 4 TX 5/RX 5 RX 6
BETA UMTS 850 5 YELLOW 5 BLUE 5 YEL/1 RED 5 BLU/1 RED 5 YEL/2 RED 5 BLU/2 RED
TX 1/RX 1 TX 2/RX 2 TX 3/RX 3 TX 4/RX 4 TX 5/RX 5 TX 6/RX 6
BETA LTE 700 6 YELLOW 6 BLUE 6 YEL/1 RED 6 BLU/1 RED 6 YEL/2 RED 6 BLU/2 RED
TX 1/RX 1 TX 2/RX 2 TX 3/RX 3 TX 4/RX 4 TX 5/RX 5 TX 6/RX 6
BETA LTE 1700/2100 � YELLOW 7 BLUE 7 YEL/1 RED 7 BLU/1 RED 7 YEL/2 RED 7 BLU/2 RED
TX 1/RX 1 RX 2 TX 3/RX 3 RX 4 TX 5/RX 5 RX 6
GAMMA UMTS 1900 4 VIOLET 4 WHITE 4 VIO/1 RED 4 WHT/1 RED 4 VIO/2 RED 4 WHT/2 RED
TX 1/RX 1 RX 2 TX 3/RX 3 RX 4 TX 5/RX 5 RX 6
GAMMA UMTS 850 S VIOLET 5 WHITE 5 VIO/1 RED 5 WHT/1 RED 5 VIO/2 RED 5 WHT/2 RED
TX 1/RX 1 TX 2/RX 2 TX 3/RX 3 TX 4/RX 4 TX 5/RX 5 TX 6/RX 6
GAMMA LTE 700 6 VIOLET 6 WHITE 6 VIO/1 RED 6 WHT/1 RED 6 VIO/2 RED 6 WHT/2 RED
GAMMA LTE 1700/2100 TX 1/RX 1 TX 2/RX 2 TX 3/RX 3 TX 4/RX 4 TX 5/RX 5 TX 6/RX 6
7 VIOLET 7 WHITE 7 VIO/1 RED 7 WHT/1 RED 7 VIO/2 RED 7 WHT/2 RED
WHEN ANTENNA LINES ARE DIPLEXED, THE COLOR CODE OF THE HIGHEST FREQUENCY PREVAILS (I.E.1900 UMTS DIPLEXED WITH
850 GSM SHOULD HAVE COLOR 4 BANDS)
����..V�- ,;Zc r3 -�
_ C� .— �`'i -.�` • . .
,. . .. _.-,:._
: . : --�
�
�'012°;�
DOUB�E GATE DETA �
5 y„_,'-o" --- -
TOP BRACE RAIL
GATE LATCH W/LOCK
POLO LATCH
GATE FRAME
02�" GATE POST
STRETCHER BAR
FINISH GRADE
OR GROUND
GROUND RING
CONCRETE OR SAKRETE
CAST-IN-PLACE GALV. MTL
"MUSHROOM" PER MFR.SPECS
(TYP) SET IN CONC. BASE
APPLE WORLD
CAMPUS COW
CCU2693/CCL02693
190�0 PRUNER[DGE AVE
CUPERTINO.CA 9>014
ISSUE STATUS
p DATE DESCRIPTION BY
08 12 13 CD 90% A.G.
DRAWN BY: A. GOLESORKHI
CHECKED BY: C. MATHISEN
APPROVED BY: -
DATE: 08/12/13
Woo
� � �__�
0
rn o r' :o�¢
Q rn� o°�
< s� v o� awa�
m`D C° �
t'+,�'l1��< m�rn w
�
.� �� �a, � Loo
� LL a �u
� �� � � � ¢w
0
��Li �; W r v �°�
� ����;. d u o w
�: d
�w�r ' •� c c w 3 w?
� � � � ¢��a
�� c �� �
� owm
W m p � ��8
" 'r, ; d c � ��ms
� �#� N� N a i z
=-•�� � U Y c N w�8
'V '.� U > �3�w
� �Y p�jzi
��
�:i.1 � � o.� �"�
-�..~' �, �"� a o
c'-�".s �; � W °�_
, �: N�
�w=�
�' N��w
&< °3
� �
�
�
H
co
cri
� �
J�m
o�
O V
�Z
O
�� tn Z
"�, � �
O Q
;�� ��
0
;�� �a
d�-.;,��,�
SHEET TITLE:
DETAILS
SHEET NUMBER:
A-6
E�ECTRIC �EGEND
MI MECHANICAL INTERLINK
OMETER
o CIRCUIT BREAKER
� SERVICE GROUND
S N G�E � N E D AGR AM
- WIRED CONNECTION
� TIMER SWITCH, WATERPROOF
\O� OUTDOOR LIGHT
� �
� GFI OUTLET, WATERPROOF
ELECTRICAL NOTES
1. ALL ELECTRICAL WORK SHALL CONFORM TO THE CEC AS WELL AS ALL APPLICABLE STATE AND
LOCAL CODES.
2. CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUIT, CONDUCTORS, PULL BOXES,
TRANSFORMER PADS, POLE RISERS, AND PERFORM ALL TRENCHING AND BACKFILLING REQUIRED
IN THE PLANS.
3. ALL ELECTRICAL ITEMS SHALL BE U.L. APPROVED OR LISTED AND PROCURED PER PLAN
SPECIFICATIONS.
4. ALL CIRCUIT BREAKERS, FUSES, AND ELECTRICAL EQUIPMENT SHALL HAVE AN INTERRUPTION
RATING NOT LESS THAN THE MAXIMUM SHORT CIRCUIT CURRENT TO WHICH THEY MAY BE
SUBJECTED WITH A MINIMUM OF 10,000 A.I.C. OR AS REQUIRED.
5. THE ENTIRE ELECTRICAL INSTALLATION SHALL BE GROUNDED AS REQUIRED BY ALL APPLICABLE
CODES.
6. ELECTRICAL WIRING SHALL BE COPPER #12 MIN WITH TYPE XHHW, THWN, OR THHN INSULATION.
7. ALL OUTDOOR EQUIPMENT SHALL HAVE NEMA 3R ENCLOSURE.
8. ALL BURiED WIRE SHALL RUN THROUGH SCHEDULE 40 PVC CONDUIT UNIESS OTHERWISE NOTED.
9. A GROUND WIRE IS TO BE PULLED IN ALL CONDUITS.
10. WHERE ELECTRICAL WIRING OCCURS OUTSIDE A STRUCTURE AND HAS THE POTENTIAL FOR
EXPOSURE TO WEATHER, WIRING SHALL BE IN WATERTIGHT GALVANIZED RIGID STEEL OR
FLEXIBLE CONDUIT.
11. WHERE PLANS CALL FOR A NEW ELECTRICAL SERVICE, PRIOR TO SUBMITTING BID, CONTRACTOR
SHALL VERIFY PLAN DETAILS WITH THE UTILITY'S SERVICE PLAN &REQ'MTS INCLUDING SERVICE
VOLTAGE, METER LOCATION, MAIN DISCONNECTING MEANS, AND AIC BRACING REQ'MT, AND
SHALL OBTAIN CLARIfICATION FROM THE PROJECT ENGINEER ON ANY DEVIATIONS FOUND IN
THESE PLANS.
UTI�ITY SERVICE NOTE
CONTRACTOR SHALL COORDINATE NEW ELECTRICAL SERVICE DROP & TELCO SERVICE
EXTENSION TO SITE COMPLETE FROM SERVICE APPLICATIONS TO TURN ON OF(N) SERVICES,
INCLUDING PROVISION &INSTALLATION OF ALL CUSTOMER-PROVIDED MATERIALS&
INSTALLATIONS, INSPECTIONS BY UTILITIES AND/OR JURISDICTIONS,ETC. NOTIFY THE ENGINEER
OF RECORD OF ANY DISCREPANCIES WITH THESE PLANS AS SOON AS POSSIBLE.
PANEL SCHEDU�E
NAI�EPLATE: PANEL A SC LEVEL: 10,000 VOLTS: 120V/240V, 10
LOCATION : INSIDE BUS AMPS: 200A
I�OUNTING: WALL I�AIN CB: 200A
0A e� BKR BKR en �e
LOAD VA LOAD VA LOAD DESCRIPTION AI�P/ CIRCUIT NO AMP/ LOAD DESCRIPTION LOAD VA LOAD VA
POLE POLE
3400 AIR CONDITIONER�1 60/2 1 2 60/2 SURGE ARRESTOR 30
3400 " " - 3 4 - " " 30
500 EXTERIOR,INTERIOR LIGHTS 20/1 5 6 60/2 AIR CONDITIONER #2 p
360 RECEPTACLES /EXT RECEPT 20/1 7 8 - " " 0
3016 SHELF 1, RECT 1 &2 40/2 9 10 40/2 SHELF 3,RECT 1 &2 3�16
3016 " " - 11 12 - " " 3016
3016 SHELF 1,RECT 3&4 40/2 13 14 40/2 BLANK
3016 " " - 15 16 - " "
3016 SHELF 2, RECT t &2 40/2 17 18 40/2 " "
3016 " " - 19 20 - » "
3016 SHELF 2, RECT 3&4 40/2 21 22 40/2 " "
3016 " " - 23 24 - " "
15964 15824 PHASE TOTALS PHASE TOTALS 3046 3046
TOTAL VA= 37880 TOTAL AMPS 158
NOTE: AIR CONDITIONING UNITS ARE PROGRAMMED TO WORK IN AN A�TERNATING SEQUENCE,
NO TWO UNITS WILL OPERATE AT THE SAME INSTANCE.
'i��,��e�3���
- , �l�� - l�, � r
, .. ----�.•
APPLE WORLD
CAMPUS COW
CCU2693/CCL02693
190>0 PRUNERIDGE AVE
CUPERT[NO,CA 95014
ISSUE STATUS
Q DATE DESCRIPTION BY
08 12 13 CD 90% A.G.
DRAWN BY: A. GOLESORKHI
CHECKED BY: C. MATHISEN
APPROVED BY: -
DATE: 08/12/13
,
_wo¢
t � �_ "z==
0
°'°°' ¢°N�
U�(�O o5w`
�CO aw°�z
��� m<p� �o°o
..� �� �� � p��a
� � LL :�
�vu► �; c� � � � w w
�
`""" w L � a�°�
y a � �ow
���.;: �3 y y �ad�
� � �, a� �o>
�� c ��;�
) owm
``i'�', m o � :'oN�
C �� �, �_ms
� � >N �s=
=—•r::;::� O Y c ,�-� �S
�,.;�`.. �p U � 0 3 N w
� �-'Y .'��
Q� 'u� ` ""`�
.r..�'�'.' � ��� a o
�.--� � � w =�_
�` wu3z
4� °�
�
� �
�
x
�
rS
� �
J�m
o�
O V
�O
H
���;�. O Q
��� ��
�" �a
�� ����
SHEET TITLE:
E�ECTRICAL P�AN
& NOTES
SHEET NUMBER:
E-1