Loading...
HomeMy WebLinkAboutAH Summary 09-12-2013 OFFICE OF COMMUNITY DEVELOPMENT � ,. CITY HALL 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 C U P E RT 1 N O (408) 777-3308• FAX(408)777-3333•planning�a cupertino.orct To: Mayor and City Council Members Planning Commissioners From: Aarti Shrivastava, Director of Community Development Date: September 13, 2013 Subj: REPORT OF ADMINISTRATIVE HEARING DECISION MADE September 12, 2013 Chapter 19.12.170 of the Cupertino Municipal code provides for Appeal of decisions made at an Administrative Hearing 1. Application U-2012-06, Federico Diaz (Oakmont Produce Market), 19948 Homestead Rd Description Administrative Use Permit to allow the outdoor display of inerchandise and to allow a bakery operation that does not involve the direct retailing of goods to the general public Action The application was approved at the Administrative Hearing. The approval is effective September 12, 2013. The fourteen-calendar day appeal will expire on September 26, 2013. Enclosures: Administrative Hearing Report of September 12, 2013 Resolution No(s) 21 Plan set 2. Application DP-2013-01, ASA-2013-03, TR-2013-12, Terry Brown(Long residence), 10049 Imperial Ave Description Development Permit to all the demolition of a single family residence with a detached garage and to allow the construction of a new two-story mixed use building with a commercial space and medical space and one residential apartment; Architectural and Site approval to allow the construction of a new two-story mixed use building with associated site improvements; Tree Removal Permit to allow the transportation of an 18.2" Coast Live Oak tree and the removal and replacement of a 24" diameter Pittosporum tree and two multi-trunk California Pepper trees on the site of a proposed mixed use building Action The application was approved at the Administrative Hearing. The approval is effective September 12, 2013. The fourteen-calendar day appeal will expire on September 26, 2013. Enclosures: Administrative Hearing Report of September 12, 2013 Resolution No(s) 22, 23 and 24 Plan set 3. Application ASA-2013-04, TR-2013-32, Terry Brown(Stanley Square), 21666-21686 Stevens Creek Blvd Description Architectural and Site approval to allow modifications to the parking lot layout to facilitate a reciprocal ingress and egress at an existing shopping center (Stanley Square) in the Monta Vista Special Planning District; Tree Removal Permit to allow the removal and replacement of four Flowering Pear trees as part of the modifications to the parking lot layout Action The application was approved at the Administrative Hearing. The approval is effective September 12, 2013. The fourteen-calendar day appeal will expire on September 26, 2013. Enclosures: Administrative Hearing Report of September 12,2013 Resolution No(s) 25 and 26 Plan set COMMUNITY DEVELOPMENT DEPARTMENT PLANNING DIVISION ' ' CITY HALL 10300 TORRE AVENUE •CUPERTINO, CA 95014-3255 (408)777-3308• FAX(408)777-3333 CUPERTINO ADMINISTRATIVE HEARING STAFF REPORT Agenda Item No. �_ Agenda Date: September 12, 2013 Applications: U-2012-06 Applicant: Frederico Diaz (Oakmont Produce Market&Bakery) Property Owner: Wayne Gong Property Location: 19948 & 19952 Homestead Road (APN 316-03-039) Application Summary: Administrative Conditional Use Permit (U-2012-06) to allow the outdoor display of inerchandise and to allow a bakery operation that does not involve the direct retailing of goods to the general public located at 19948& 19952 Homestead Road. RECOMMENDATION: Staff recommends that the Director of Community Development approve the Administrative Conditional Use Permit (U-2012-06) per the draft resolution. PROJECT DATA: General Plan Designation Commercial/Residential Zonin Desi nation P(CG), Planned General Commercial Environmental Assessment Cate oricall Exem t Lot Size 72,745 s uare feet(1.67 acres) Project Building Area 1,322 square feet (Oakmont Produce Market); 640 square feet (Oakmont Baker ) Pro'ect Consistenc With: General Plan Yes Zonin Yes BACKGROUND: Site Description The site (Oakmont Shopping Center) is located at the southeast corner of Homestead Road & N. Blaney Avenue, with the City of Sunnyvale to the east, and light manufacturing and research uses to the soutll. The project spans two tenant spaces. Oakmont Produce Market is located at 19948 Homestead Road. U-2012-06 Oakmont Produce Market&Bakery September 12, 2013 Page 2 � , .. � � ����w� � r � �: �,,��.�� � ¢ �� , „ . ,;. .' est�t �,4"� .. �^^^�, *��� �� '� :x:s.�e::ar-*c.�c�r'" a'sc.ic.a�Y tic,.... ,a x s� r,� , �.� �,: . `" ° �' � "" . , '"'!t �,��.� ��"�.:��� � �r�� », ... "+��;� � ,t� ar�`��.�il��``.� , � ; �� „o � \ � � �. > .. �_ � . " �� '��►� � �„� � ��,a � ,� m �, ,��� � ` � � , , .�. , r. '""..�„ �- � �° ��� � '6�y` ,� �+� ���� � �».� � � � t n � �'� , ¢ �f v .r ��pz �'w � °'� � �.� � � .. � .8 �.�. �.3 a� , . `�0�' '� e _ .�. _ ° � m �.�,�,��'� .s � \ r -�" • �«� ..�:r."''. �.:�+� "., ,.,,,. ��. „. ( 1 . ^. �. � � -;�,. , . .�: � �. Asa� �.,�,�,,. i ,. @" . . : �.�.a , ,. .�..._P.. ��� a � !� � \�\�,�'a�` .. .. , - . . � "� . � �� .... m� �„' �"'� , �y- «"�^ . '�" ,� ,..' , . ;'�' . ,, �a� ��- .�� t ' .o ..:.: "aPo-�^r"'�.�-s ma�ea.� ���r � �,`� �.�,..�r�--�*M . "-� . "* . �.. �� . .. ,. .. : ;:� �^�x � w" i �.� �.� ' �:� ,y�,�� g J�..k �� k r �4 � , ,�� �� �,��, `�� "°.r�"�i ,_ � , `�.ar � � : � � � � � 5�^s�` �,�6- .� a+"° � •. ��'• d �9 yy_,, ��'^��w.,�` -„.�...., ;7 �^� i wM �t `� ��"'' � ' k ^�"•� ..,� r .'� i� �1 . m, a . . p .. � . . � . , . � 1. ` sw i � � � . ... . ... ,�� . .� �- . : .p . . ��� � 4 —,�� �1 ,a� ��� " � � ��::�� ... F .. �E � �'.� !1 � i�a«e .., . i � �.&'�+�� ', ,� • ' , . . ... . . . . . � , , �� ��. � � � � °,� � - �M �. , x ..,, �� , .� - .�.�r. ,� �,� ,�^ �,�.. <.��� „ ,'3ts� ���� r�"".� �J�p � ��>,�� ,��� „��^"� ,�� ++'�i��' � , ., , F .: "'^ � z e a c,,.�, �� k ��,°� �c,�; �v�`� m ��ua t�;'^ ' �:., .:. �a_.,az.�.u����.w„„> �W x `" - ��.; , ,� .��. aie`0�d �:k�Ff�,k��P ��,�;.w P� � .��.� � `c`q �a�``:,�, �N�.`�ss"�`t3�`�"�i�Sa. �a .x.� _._�f�_ x.. � '�,,...�t..:�, , �"�` � '' , • � -e _.__:_ w ._ . .:. � ����- � • • • > �u' ;a".:�'i ,� �' d?�" � < .. -�e . 'q' . .. �'�� �s�� ,.:,9'k'a?�� ..� " � ' y • � ... * ,h,1 A. q � 'C ^�.,. + ' � � ' .. ��' . �T.::�r�u���.F � . �:.,�'^i " �� :�.on A" @p .� � �`� 'u """"' ;�n� � ^�:� .,._..,� .`�': �!��.J4.�_.,1•.,.� y�.�,y : - 7 j + , ._ ��� , ,�,� "� .�''m x.. t<�� .. �c?SEi � �A"!IA�!"'�'7 . "��'!�S�1 �� � . " a .x , . �,4 n .. ^' ' +tr � \ �� �!! ^ ;� �.a��,,..�M" '� .. �9 .b� "R°61' � M ,. �� '�a '�� �� �,d °d°� 1 � � .,..'W.._... '." .. • . . .^ ''. � � ��` .��� �� "� �k i� � �:9���"�',, ���w�� � .3 k � � � � . � fi `'# te �:.���� <,!� � �'�� . � `� . .. . • .. . . , .:., � d �. , � =..a. . "? � - �< -� « ., ^ ..� -� s- . �� �.a� � � P^ �A .. ,-„ �.�, is �� � ,� ,�& � � k ".. .,....� a, e. . _ .. � e � , .� ....�n . �:�b' ,.x., ��, ,-v -_ . '� . �', � f�:. � .�, . �: .. . �, -� -..- , ` _.._ .�.�.,.,.,. ,. _ -. � � � . . , � , , , . , . .� c, . t . : .,. , w. , ,� ._� �. ,��� �t �.� y . . ���.x- �� - °��� ,�. � , � w.� - � �.� � �� � �� �...,.� � . � � �.I�;�, ���� � ; � :� _ � �, . _... .� .. -. , � �a . � '-'.,.,,�.._,�„. . .�,. _,-*..»-=�,,,� -a w „���� .,��^ � �� ��� � • �°� �,, ' �.-�:� ,FX�°'" * i � + � ,,;..� fi i w.., � �ry. . �1,5:w� +$4�._►a::�� �1 ���. ' a�a����'� .� � � � �o� ., � , w,t� �'�� �'r �y q E �� . � :.i y�' � m. ��R�' �,��� ` -i..�.,11._.*....._._.____"5_..�.JL � z .. . a .��--. - . s ^ ` ,�,.�,y} � ... �.y�a,»aprr� �"l.�.'1^�iw;•,� �"'y'.'�° � ,��°,.. � "� ":�.: • , . "� t �.. � � . -r;.: ��!�;�,,� r ° �+.:. , . '�a F . . .. . . . °M"`P'' ,s �► �';"a�."�,y^'H(� z �,� "� �k .:+ q � '� t'� F �' '�+ , � d y� r '!M. ��... � , "� . . _ �{ . � e „ . � ;�i'�° �> � � F � -� � '�'� �1 t � .. �'o,� .....�.'� " ,- .�. � . � ..t��L...� � . .,__. � .. � � . ��'°R �_ � �"� �. "' '�� .;. � � . L". �Y ' � �.. � .• � � s � � „ � .... .,�.: �� . .,. . � �.. .. r � �,: ,.: �, .. �r,� '. . .. � �, � .. ^ � �'b. .., lF�;;�'"'P� . `� .:� �?1�;,` . .._, \Y � �.� ' r es.� „, � y �,..��� m - .. �u. _ „ ..,. "[1 `s ti . r a r .r�+;e . 'nSy:�z,��"'�p"" �� ' . ' Xe,) : � �T ' �...�' .o L"! �v �'.♦ ,", $� �^�"'�.,.n..,..,� �Ky :, : . . ��� 5�� � � � � ,� �� � � "�1 � � �� � ��15 k >r°i lg9� - � ' '� '� f'4Atl .i .m . �� i�d .,e��` �r� ���i.�� ��f . -_ ..„� ` m'�('� ... '�: �V, � ~ . y R' � . 9 e (y ..�,�". � �S..�ie �(�' � ... ,� ._.. � �� �^ �1 '�:.5� . � �`+ �� �'�W aix� �.�ir.�� .1 f��# ..� a :� # ,„ . ���' �4va'� � �.. .�r� 1 :!� �...���� �. `" �i ;�. .we�s ..,_ 4 aV,�C : °. . e a. y�. ... '"�y � �� . . �. ��^y',*j � ?,�' . . �" .p� , , �� 4 .. � ♦ .. � ». ,,�"�+�• � � "a� �� �' , �� A.,,� �,�' - + � . , ,�*s".ii� -� ,�, j� .:,�_�m `�, ',� y ��N „� �..�i: ti a,�..,�� �.� a�� '�t a�-� �'aw w.,A` #:��� T � � .. , ... .'tS'.1 �."� a"y�3;e � .�'.'��ti', �-f^ :� . m� '� ���,+ �'�" � ���,A iw�,� � ...}"'* ` "'�, � +� :`� �a m' ��r . R �, . � �d>" ' ,r, � £ t � ��` ,�� ., �, , � • �� �.., ra �, . � .„w , s. � „�,r, 'j .., . �C ^r' ```��'R'R}� +�y��l�'r", t: � � y r v-u r�s?a��� � � 1 �� ..-� t ._ , � ��• . �7 . -ay . , � �� xe .c,,_,,.,,� -'1 ,t, S,�a,"°�s �^�'1 `v 91 .. � , `'; , � ', > , `� �' �;r� .�w k� � � r�i �-°�rs: ;^�, '"r�C�i t,.^'.,� ` .� � .. . „� .,� �K,��-a�- nY`. •A. , r _ �. . ... µ f . .�. .� �4 � , �a,'�'I � ���, � j � � � „� � „�� -�,e�mu ����,3'�'+A' ��r��, � � . , • ,... , .. _ ,, it,�,,,. is,.. . �r� . ��i,...,, �_.,sa"e.�;f,.x !1 �,y,.:.. a 2�:..+' . ��: '..'�....... .:�.�. -,+y, ,--,L!RlT, � . . 2:. . "a .: . . �.. �� K dti�� . ..,..�.aro.�.,�...._.,. �, .. . :., . .. �. .` , ... „.., . .+�:` ... . ..e..wae�.v,�,w..a�...�.�ac..e���«..,x..,,�..�..m� �,,,�� Previous City Approvals On September 15, 2004 a use permit modification to the prior Use Permit (U-2004-02) was granted on the subject property to allow late night operations for a karaoke studio, and denying a request to convert a storage room into a studio room in the Oakmont Square. A previous Architectural and Site Approval (15-ASA-01) was granted on July 5, 2001 establishing final colors, materials, landscaping, signage, and other architectural details for an approved addition to the existing shopping center. The proposed plans do not conflict with either prior approval. Application Request The applicant, Frederico Diaz, is rec�uesting approval of existing outdoor produce carts and associated display equipment for the Oakmont Produce Market and to allow the Oakmont Bakery to operate from a nearby tenant space without the direct retailing of goods; goods for the bakery would instead be sold at Oakmont Produce Market. This use permit application also seeks to address an anonymous complaint of produce bins obstructing the accessible parking spaces in the parking lot (Code Enforcement Case: 11-001502). While no bins have been observed in the parking lot, this permit has been conditioned such that the outdoor display must remain clear of accessible paths of travel and parking spaces. U-2012-06 Oakmont Produce Market&Bakery September 12,2013 Page 3 DISCUSSION: Outdoor Display The applicant is proposing eleven 4'x3'4"x34" larger, and six 4'x20"x34" smaller produce carts on wheels and patio umbrellas for shade. The proposed carts are green with diagonal white wooden cross beams (on all visible sides) and recessed produce displays. ._. m. ..��..�. _ q K... . o,....«. ._....,...��..,. .,..__.._. ,_.�...._�....�.�.,..�-�-.,... �� ��^^�mnwA� .. .�w�.w�--«�"..,.t..� ...--....�+-..-..+rr ,�.N.n!^�""�"°° w n � ..,. ..__.-.......��.. . .v .. ..-.�-...............- _...✓r.Y.T_i.w+--,....r.�-.� ..Y.., �.. ..... ( . .................iw.r „ ��..�.-._.-._.. .�..�__.. .-...-......r..... .m�n.�. ....-.. t . A �P � � �.�». � �c.'..-._. �wwww"..wrw+w..�.� ;'4 _.,, ..�..�._ c .�_..._..�,. .,.. M...,...«..�.«.._ .. , � ' � ��� � �'� r , ^�`r _._ .... . �, . ,,, �. ». , , �, ., � �'- ' �'°� � � _ ..-- � . . � � - � ., �-�__ ,.. � �,_.. � � ��� �� ,� �� ..,�� � � . : _. _ _. --- �� � ...�:�-� �� � x � .__..�. � ,. ,.,�.. 4 .. ." ' . . �r' . ' . ,-..__. :..` � 'Mm.a _. a , 8 4 y}� �� �M��L„ _�.. ....... ��. ��� _ .___ ,., . � . . _ . .�,� .�_ .. ��� _ . ,�� �.�. �� � �� �, ,. �: R �_ �. �.�: I'roposeci �3in llesi�n As conditioned, the produce bins and umbrellas would be required to be brought inside the store at night at the cessation of business hours or 11:00 p.m. through 7:00 a.m., whichever is more resti-ictive. Building Exterior Refinements The application would be required to provide a new cover to an existing trasl-� enclosure and a cart corral on the south side of the grocery for shopping carts. �,�`�-- �.. ---_ ____.___-� - "� _____._ .- ''� '=, ..---��� ? , �., ��,�,�� _._., , ��� � � � � - -�'� . �: �' i � � ' � Q ga �.;� �%': ^�r �7 °,�--✓'-^ r ' � ; ; �� � �� �;1�°0 ;��°, �� !; ��; ��'�.:=~� a�� �<; - --� ��1 ,� _,-.. .� .-_ . . _. :_ _.______..__-_ _ . .. _ A.__ _ ---�_.__ __-- � �, °� �°�� �� , t_.>_. ,r.a�E- �F�a5sa a�EA � ,�`""_.�` f�"-Q� ?3�s SzE��POS� E�XISTING 5"-6"t��ETAL FEtv �� 2�to��a=ea�t:�a�r�c�c7. AND GATE ?�?a�*;'�:���c�fp a�a*C�t=_ : �s ._ � � :z�.' . , �------- Proposed Front Elevation U-2012-06 Oakmont Produce Market & Bakery September 12,2013 Page 4 The application also requires the removal of rolled drapes that hung from the roof eaves and the shelves attached to the edge of the produce carts for aesthetics and to accommodate wider paths of travel, particularly those serving the primary entrance. Rolled Drapes &Shelves � - � ���� �_� � _ _ � �� . �, �. �; ,, . _ ��. � , �. ; � �,�� � ���. ���� �,n , � : ` . �� a, . + ����� �w�.�.. #��,�es.. � � .,.::.��.3� !i # a � * : JG G n �'q `� �' � aiMMI�R a �! "'',�-c.. °�Y • � " x .. ��° =vexaee.. � �. , � „�„ � � .,, ' ^.� .. a.< . . .... . -' � "� � "'" ��g.•- �� �u ..;,. . �, i ��s.:.'� �^"fit�'ty'kC".;. i�:"7 �w�-. ��r� � �t r ��,.� e.� , �. . , \\ � �I ' . { t�'j �i �� � a�� �--�"a '�"'� ` < ° i,d � . � �,,� �. , t . ,. �� .� ,y , . � . <� , � �h.,.,. , j. .- . ae -� . . . '�' a `' :- x + � � �� ' ��� � � �tl� .�^.P .. *"�::. ��� � � t' .. ��;m�s," Bakery Operation (Non-Direct Ret�il) The Oakmont Bakery has been in operation since February 2012, through an issued building permit, without the benefit of a use permit or business license. The applicant is requesting to legalize the bakery use by incorporating it into this use permit request. Typically the City discourages non-retail service in commercial areas, however, given that this use is already in operation, serves as a direct extension of/in close proximity to the Oakmont Produce Market, is adjacent to light industrial and utility uses, and is located in the most interior and least visible commercial tenant space (adjacent to a rear loading dock) of the shopping center, staff is supportive of it. A condition has been added that if the Oakmont Produce Market or Bakery discontinues operation, the space would be subject to review by the City with the intent of returning to a general commercial use. Furthermore, the goods produced at the bakery shall be made available for purchase through the Oakmont produce market and the storefront windows of the bakery are to remain unobscured. Outreach, Noticing, and Public Comments The following table is a brief summary of t11e noticing done for this project: Notice of Public Hearing, Site Notice &Legal Ad Agenda • Posted on the site (14 da�s p�-ior to the hea��ing) • Posted on the City's official notice � 61 notices mailed to property owners within bulletin board (one week prior to the 300' of the project site (10 days prior to the hearing) hearing) • Posted on the City of Cupertino's Web site (one week prior to the hearin ) U-2012-06 Oakmont Produce Market&Bakery September 12,2013 Page 5 ENVIRONMENTAL ASSESSMENT The project is categorically exempt from the California Environmental Quality Act (CEQA) per Section 15301 of the California Environmental Quality Act(CEQA). PERMIT STREAMLINING ACT This project is subject to the Permit Streamlining Act (Government Code Section 65920 - 65964). The City has complied with the deadlines found in the Permit Streamlining Act. Project Received: September 2$, 2012 Deemed Incomplete: November 29, 2012 Deemed Complete:August 13; 2013 The City has 60 days (until October 12, 2013) to make a decision on the project since this project is Categorically Exempt from CEQA. The Director of Community Development's decision on this project is final unless appealed to the Pla�nin,g Commission within 14 calendar days of the decision. CONCLUSION Staff recommends approval of the .proposed project, as it is compatible and complementary to the existing shopping center. Additionally, all of the findings for approval of the proposed project, consistent with Chapter 19.158 of the Cupertino Municipal Code, may be made. Submitted by: Stephen Rose, Associate Planner Attachments 1 -Draft Resolution 2 - Oakmont Produce Market Business History (including Letter of Explanation, Statistics and Market Exhibits) 3-Produce Table Design 4-Plan Set CITY OF CUPERTINO 10300 Torre Avenue Cupertino, California 95014 RESOLUTION NO. 21 OF THE ADMINISTRATIVE HEARING MEETING OF THE CITY OF CUPERTINO TO APPROVE A ADMINISTRATIVE USE PERMIT TO ALLOW THE OUTDOOR DISPLAY OF MERCHANDISE AND TO ALLOW A BAKERY OPERATION THAT DOES NOT INVOLVE THE DIRECT RETAILING OF GOODS TO THE GENERAL PUBLIC LOCATED AT 19948 HOMESTEAD ROAD SECTION I: PROTECT DESCRIPTION Application No.: U-2012-06 Applicant: Federico Diaz (Oakmont Produce Market) Location: 19948& 19952 Homestead Road APN# 316-03-039 SECTION II: FINDINGS WHEREAS, the Administrative Hearing Meeting of the City of Cupertino received an application to approve the outdoor display of inerchandise and to allow a bakery operation that does not involve the direct retailing of goods to the general public at an existing shopping center. WHEREAS, the Administrative Hearing Officer finds: 1. The proposed use, at the proposed location, will not be detrimental or injurious to property or improvements in the vicinity, and will not be detrimental to the public health, safety, general welfare, or convenience; Allowing an outdoor produce display for an existing produce market will not be detrimental or injurious to property or improvements in the vicinity, and will not be detrimental to the public health, safety, general welfare, or convenience because it will provide greater accessibility of goods in existing planned general commercial district. The non-direct retailing of goods produced by the bakery will not detrimentally impact convenience to the public in that the goods shall remain available to the public through the Oakmont produce market. 2. The proposed use will be located and conducted in a manner in accord with the Cupertino Comprehensive General Plan, underlying zoning regulations, the purpose of the City's zoning ordinances, and complies with the California Environmental Quality Act(CEQA). The proposed project is consistent with and will be conducted in a manner in accord with the General Plan, Zoning Ordinance in that the use, subject to this approval and as conditioned, meets the requirements of the Zoning District and General Plan and does not conflfct with any prfor approval. Furthermore the use is categorically exempt under CEQA in that the proposal involves a negligible expansion of the existing use. The project serves to achieve diversity in land use (GP Policy 2-20) by providing an employment center and neighborhood serving uses (produce market). The conditions of approval contained in this resolution further reduce the likelihood of adverse impacts to surrounding properties. Resolution 21 U-2012-06 September 12,2013 Page 2 NOW, THEREFORE,BE IT RESOLVED: That after careful consideration of maps, facts, exhibits, testimony and other evidence submitted in this matter, the Application No. U-2012-06, is hereby approved; and That the subconclusions upon which the findings and conditions specified in this Resolution are based and contained in the public hearing record concerning Application U-2012-06 as set forth in the Minutes of the Administrative Hearing Meeting of September 12, 2013, and are incorporated by reference herein. SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY DEVELOPMENT DEPARTMENT 1. APPROVED EXHIBITS Approval is based on the plan set titled "Oakmont Market, 19952 Homestead Rd, Cupertino Ca," dated Received June 4, 2013, consisting of four (4) pages, labeled TI-1, TI-2.1, TI-3, and TI-3.1, and exhibit entitled "Produce Table Design", dated Received August 16, 2013 and consisting of one (1) page except as may be amended by conditions in this resolution. 2. ANNOTATION OF THE CONDITIONS OF APPROVAL The conditions of approval set forth in this resolution shall be incorporated with complete written annotated responses into the building permit submittal. 3. ACCURACY OF PROJECT PLANS The applicant/property owner is responsible to verify all pertinent property data including but not limited to property boundary locations, building setbacks, property size, building square footage, any relevant easements and/or construction records. Any misrepresentation of any property data may invalidate this approval and may require additional review. 4. NUMBER SIZE AND LOCATION OF PRODUCE BINS&UMBRELLAS The total number, size, and location of produce bins and umbrellas shall be limited as shown on the project plans and shall remain clear of accessible paths of travel. No additional bins or umbrellas shall be permitted, nor shall any increase in size or revision to the location be permitted without a separate approval. 5. DESIGN OF PRODUCE BINS The final design, and colors, of the produce bins shall be as shown on the approved "Produce Table Design exhibit, noting that diagonal wooden cross beams shall be provided on all visible sides. In no case shall containers in which goods have been shipped, and/or alternate styles of basket/bin displays be permitted without prior approval of the Community Development Director. 6. OUTDOOR DISPLAY Produce bins, umbrellas, and other ancillary display equipment shall be returned indoors every night at the cessation of business hours or 11:00 p.m. through 7:00 a.m., whichever is more restrictive. The ground and surrounding areas shall be swept clean and maintained in good condition. 7. CESSATION OF USE Any discontinuation of the use of the produce market,bakery, or outdoor display shall not be permitted to be reestablished without prior approval of a new discretionary permit application. Resolution 21 U-2012-06 September 12,2013 Page 3 8. TRASH ENCLOSURE Protective bollards shall be installed to protect the gas meter adjacent to the trash bins. The exact number and placement shall be determined as part of the building permit plan check process. Furthermore, the Oakmont Produce Market shall share the recycling bin with the adjacent Dentist's office and dance studio. 9. BAKERY Goods produced by the bakery shall be made available for purchase through the Oakmont Produce Market. Furthermore the storefront windows of the bakery shall remain unobscured. 10. CONSULTATION WITH OTHER DEPARTMENTS The applicant is responsible to consult with other departments and/or agencies with regard to the proposed project for additional conditions and requirements. Any misrepresentation of any submitted data may invalidate an approval by the Community Development Department. 11. INDEMNIFICATION To the extent permitted by law, the Applicant shall indemnify and hold harmless the City, its City Council, its officers, employees and agents (the "indemnified parties") from and against any claun, action, or proceeding brought by a third party against the indemnified parties and the applicant to attack, set aside, or void this ordinance or any permit or approval authorized hereby for the project, including (without limitation) reimbursing the City its actual attorneys' fees and costs incurred in defense of the litigation. The City may, in its sole discretion, elect to defend any such action with attorneys of its choice. 12. NOTICE OF FEES DEDICATIONS RESERVATIONS OR OTHER EXACTIONS T'he Conditions of Project Approval set forth herein may include certain fees, dedication requirements, reservation requirements, and other exactions. Pursuant to Government Code Section 66020(d) (1), these Conditions constitute written notice of a statement of the amount of such fees, and a description of the dedications, reservations, and other exactions. You are hereby further notified that the 90-day approval period in which you may protest these fees, dedications, reservations, and other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest within this 90- day period complying with all of the requirements of Section 66020, you will be legally barred from later challenging such exactions. PASSED AND ADOPTED this 12�" day of September, 2013 at a Regular Meeting of the Administrative Hearing Meeting of the City of Cupertino, State of California,by the following roll call vote: AYES: HEARING OFFICER: Chao NOES: HEARING OFFICER: none ATTEST: APPROVED: /s/Ste�hen Rose /s/Gary Chao Stephen Rose Gary Chao Associate Planner City Planner Attachment 3 ro �c a �e _ _ �, � �.��......� ,_.�_ __�_� _.________ . .����� . , _ t � a r , ___��__..._. _____._ � �.... __�_ :..�.�� �_ _____�.�__� � w . _ �._._ .._� �.r_ . � � a _ _ � �._._. .a .� __ .�__ � . _ _ ... - ;, ,,�" �� _,,.�. .. , _.�_��.�� , °, ���..�.�__,4�..� _.�_ r _�� , , .� '� _.,. ' _ _ , ��., � . _ � . _��._ —..____.___... � � �, � �'� � ``��� � a � � � __ .. � ���� � � . � � , �, �'��`,�, �,,�. . �., � .._ _.._._.._--- „�,� ;� , '� �,. 1 t,._ �� °�� ' � � __.._.�.,... �� � �.,:.,.���,. __�._.._.. . __. „ , . _ ,. �. ,. � r,� .: : ,�" ; ° � — -_:'. . __ � ..��,ro<,�,�.�,,;, � ,,,: ;�` -�.,.___..____.. �� �,.�-- ! : ��' �- ; r �- s ,, �E � � � a .. ... ,�.._. �f _....... ��.� ....vmMi�:::rYLm•...., . � � �T � - W _ . . . � � ��� �_� . . ������ �..�.==�.. W - - �� A.� . �� _m��. . � � � � w �;# . �.��r ���� �,� �� �' � � � �� � _. ���� � . _.�,��. . �. ,.�... .. . � � � �. ._.. �. �_.�.__ „ , : � '� ,.. �� � _..�. m _ .... N_... ..._ ,_. _.�....._ � _ - �R. n� , __.- � � � � . . ;. v, � a p....�..,m_,..�,.....«."""..^'"^^+�.oemma�,� ,�m, ' �'�.u�.n......::....�M,,,,«-u � . � . ..- dwmWw�^ ....�:....�,. . ._ c,�'. ..,, w�. ;. � '._�ev w 1,. -. r, � .._. .._... '�_ w � ,. , . w . � _......�.............�.. -. «_ . ., ..M, . ,. . . ... . . „ . . . .„,� �.,...� ... , �:,,.�� � � ° � s. .::,..,�..,. .. � . ' ' .. .�A�,,;.,„.�..,,,.....,.m ���f �4 .. ... �r. x'A" �/�� ..., ...�.,A,,. .�«..�-•.... � $ i s a� 1 : , , � . �i., ,�.; �� e�. •e . ...._..�. � .R .... .... . ....,. . . . ..:.: , . rcM� . .� G. , V� Yf`� � .,. W a' . ... ,�rn n. .'�2 � �"C z,a �—,�,..,,��,.... ,�w �a�s, ""���+` ��F�� ���� ���i `� `� f�� ;�H,.�...d.a.�...�� � .... .�_� ,.. « . ...., ..�^^'� .. ... ��?;:��� w�� � � � Y �,���°���� ''� �� ,.„�.. > „ � ' »�.. ,�� . � ,� , o „ � • . �°k� � � rm .. �, � °�' �„ . �� ,; �' �:d .. 'S� -�r. ,� '� � r � �� ..., , . .. e . . � y . .... ... . '"_ . _ �.b .�, >> ���� �� ,...�,,.�,m;s�m�� . W ...,. . �.,..... .. , , .. , .,. ., .. �,, s _;� . .�_.. ... ,.,_� � , w-..-^.,:u�^>°.^ ��,�,. _ � J�� ^�"���� j id,l iil�i�Pe¢,I�. I� � '��Il�,�rl��� , . __ : .,_. �� ; - �k. �� � ....w,�.a ..... . � ...w��"P'�M�'.F ... 41+r+n—.� `' �^'{ m`,,�'•q5�;�'q`*��q°`^R��1�j},)F°' � , rJ/ �I5' ,1(�� ��V� �U 1,J"#d"tt,'�, w�.�tw *.9�: �TM, t' 1 1 � V AM✓Y ., . _.�� :1 - . 1J �..�.u..k.,�.�_. �(��-���� �_'..�.�..�_____._ U G S 2013 � �� A 1 . ._ .A v_ ..—_ ��,�; B PROJECT CODE NOTES: CONTRACTOR �IABILITY: SHEET INDEX: ALL CONSTRUCTION SHALL COMPLY WTIH THE CONVENTIONAL 2010 CBC UNKESS OTHER WISE NOTED CONSTRUCTION LIABILITY TI-1 COVER SHEET CONTRACTOR TO VERIFY SITE CONDITIONS AS THEY TI-2.1 SITE PLAN RELATE TO THE APPROVED SET OF PLANS,ALL TI-3 FLOOR PLAN DIMENSIONS MUST BE VERIFIED PRIOR TO CONSTRUCTION CONTRACTOR AGREE$THAT IN ACCORDANCE WITH TI-3.1 FLOOR PLAN BAKERY CONSTRUCTION GENERALLY ACCEPTED CONSTRUCTION PRACTICE�,CONSTRUCTION ALL WOOD SHALL BE DUG FIR#2 OR BETTER CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE METAL STUDS SHALL BE 25 GAGE UP TO 10'AND 20 UP TO 20' RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF ALL STRAPS SHAL BE SIMPSON CONSTRUCTION OF THE PROJECT,INCLUDING SAFETY OF ALL PERSONS - ALL CONCRETE SHALL MEET A MIMIMUM OF 2500 PSI AND PROPERTY;THAT THIS REQUIREMENT SHALL BE MADE TO APPLY ,� � �-� Q / ,.��n j��/�/ CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, Jl � ►it_ (>� ��v� ALL REINFORCING BARS ARE TO BE GRADE 40 P::� �,...JL��.�- � �--�---�°^^^°^"' " ` AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, : INDEMNIFY,AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY '�°N+�" -`''�` '""" "�"� ALL CONSTRUCTION SHALL COMPLY WITH THE AND ALL LIABILITY,REAL,OR ALLEGED,IN CONNECTION WITH THE ��h�/ 2009 iBC CODES AND COMPLY WITH ALL STATE PERFORMANCE OF WORK ON THIS PROJECT,EXCEPTING LIABILITY � V�� AMMENDMENTS 2007 ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL. ��'�-���fV J F 1-ALL METAL STUDS TO BE MIN 25 GA6E UON - 2-ALL WOOD SHALL BE#2 OR BETTER 3-ALL STRAPS SHAL BE SIMPSON NOTE �' 4-ALL CONCRETE SHALL MEET A MIMIMUM OF 2500 PSI k� "���� 5-ALL REWFORCING BARS ARE TO BE GRADE 40 THIS DESIGN IS FOR THE AREA OF ADDITION ONLY.NO 6-ALL GLASS TO BE TEMPERED AS REQUIRED BY SECTION 2406 CBC WARRANTY(AND UP-GRADE)AS TO THE QUALITY OR STRUCTURAL 7-PROVIDE GFI PROTECTION EXTERIOR OUTLETS&RESTROOM, INTEGRITY OF THE EXISTING BUILDING OR PORTION THEREOF IS AND AT ALL SINK WITH WEALTHER PROOF EITHER INFERRED OR IMPLIED BEYOND WHAT IS EXPRESSLY WRITTEN - � 8-INSTALL SMOKE DETECTORS IN THE SUPPLY SIDE OF AC UNITS 2000 OR SHOWN ON PLANS OR CALCULATIONS. � '?'� �� � CFM AND ABOVE I�� � � 9-HEATING SYSTEMS IN THE ATTIC SHALL COMPLY WITH �' THE 2007 UMC � 4 10-WATER HEATERS ARE TO BE STRAPED WITH A PAN IF IN THE ATTIC �'" III \ � P,T,TO THE EXTERIOR ,I 11-PROVIDE PROPER COMBUSTION AIR FOR BOTH WATER CODES: PROJ ECT DATA. � HEATER AND FAU 1 2-ALL DUCTING IS TO COMPLY WITH CHAPTER 10 UMC BE CLASS I DUCTING 13-ALL WASTE AND VENT ARE TO BE CAST IRON ALL WORK SHALL COMPLY WITH. qPNE P(CG) G 14-ALL WOOD EXSPOSED TO WEALTHER ARE TO BE PRIMED OR PRESSURE TREATED OCCUPANCY TYPE a 1 5-ALL GAS PIPING TO BE 6"ABOVE GRADE 2010 CBC CONSTRUCTION TYPE va 1 6-ALL HOSE BIBBS TO HAVE BACK FLOW DEVISES SPRINKLERS No � 1 7-ALL EXTERIOR DOORS TO BE WEALTHER STRIPPED 2O�O CPC TENANT S7ACE i322.o0 SF 1 8-CONNECTIONS SHALL COMPLY WITH TABLE 19-PROVIDE GREEN BOARD AT TOILET ROOMS MIN 2'-0"IN FRONT 1 SCOPE OF WORK _ 4 w 2O 1 O CMC LEGALIZE EXIST STORAGE AND BAKERY o u w 20-ALL TOILTS TO BE 1.6 GAL MAX � 4 ° � ` 0 NO NEW LIGHTING OR HEATING/COOLING 'f' N ° � 21-ALL EXTERIOR PLYWOOD TO BE CDX �onos � � � g d 22-MAIN DOOR TO HAVE A SIGN OVER IT"DOOR TO REMAIN UNLOCKED DURING ZO�O CEC � �= 4 ' BUSINESS HOURS. PARKING STALLS 85 23-AI.L DOORS WILL BE PROVIDED WITH 10"KICK PLATEA AS REQUIRED 2008 ENERGY REGS ACCESSIBLESTALLS 3 24-ALL INTERIOR FINISHES SHALL COMPLY WITH CHAPTER 8 CBC FOR MAX FLAME SPREAD AND SMOKE DENSITY Site Area: � 2 5-ALL EXIT SIGNS$HALL BE U.L.LISTED AND APPROVED C O N S U LTA N TS. Net Area=52750.03SF-1.219 acres Gross Area=72553.03-1.6fi acres �p' �` m m m � 26-ALL INTERIOR COUNTER$TO HAVE A MAX FINISH HEIGHT OF 34"A.F.F. Building Area:20958SF � �' w � w � 27-ALL SWITCHES&T-STATS TO BE MAX 48"A.F.F TO THE TOP OF THE BOX Floor Area Ratio:(20958/51595.03=.4062) N � � � � Number of Stories:1 � � g u � �, _� 28-ALL ELECTRICAL RECEPT TO BE MIN 1 5"A.F.F TO THE BOTTOM OF THE BOX Height of building:18'-0" 29-MAX HEIGH OF AlL DOOR THRESHOLD$1/2" Number of Employees Project(Produce Srore 5 8 Bakery 2) t ' =° 30-ALL NEW DOORS TO HAVE LEVER TYPE HARDWARE � � � Parking: 31-PROVIDE TACTILE SIGNAGE AS REQUIRED PER CHAPTER 10 CBC. Required Stalls 84 Provided Stalis 85 Accessible 3 IF BUILDING IS EQUIPT WITH AUTOMATIC FIRE SPRINKLERS OR HOOD&DUCT SYSTEM Hours of Operation:6am to 9pm(Produce Store 8 Bakery) � 1.SPRINKLER CONTRACTOR TO SUBMIT 5 SET OF SPRINKLER PLANS TO THE Existing Use:Produce Market �- �� Proposed Use:Produce Mark with Outdoor Sales and Bakery �,,��,�, � FIRE DEPT FOR APPROVAL PRIOR TO THE FIRE SPRINKLER INSTALLATION Zoning Designation P.(CG) � L`�' � I � General Plan Designation:Commercial/Residential Z �p�.K? _ ,� � ` � O �Q � �� Z�V O �C MAP LOCATION: CODE ANALYSIS: � ��N �� � `� � . • - _ "�,��. � � ABBREVIATIONS �,. .,,. �. � ` ...,...�..�� .. � .�,��. � & AND (E) EXISTING REINF REINFORCING INT. INTERIOR ; M � L ANGLE EA EACH RHWS ROUND HEAD WOOD SCREW KEC KITCHEN EQUIP.CONTRACTOR � ' o . . ' " @ AT ELECT ELECTRICAL RHR RIGHT HAND REVERSE L LENGTH � 0 DIAMETER EQ EQUAL RM ROOM LAV LAVATORY ' _ DEGREE EXT EXTERIOR RO ROUGH OPENING LF LINEAL FOOT ''" ���" ��� � :..., p .� � # POUND OR NUMBER FE FIRE EXTINGUISHER RWL RAINWATER LEADER LH LEFT HAND � > F-� . m SQUARE F00T FEC FIRE EXTINGUISHER CABINET SCD SEE CIVIL DRAWINGS LHR LEFT HAND REVERSED ; '""''' °"'" �� W AB ANCHOR BOLT FHWS FLAT HEAD WOOD SCREW SCH SECTION MAX MAXIMUM ", "'Q' � }--�--�—^�---. U � ACOUS ACOUSTIC FIN FINISH SED SEE ELECTRICAL DRAWINGS MB MACHINE BOLT �� i`• � 'i ; ' ` �� ACT ACOUSTIC CEILING TILE FLR FLOOR SIM SIMILAR MECH MECHANICAL """^""�"� ��� ��� (} ��� �'' �r �� � ; ���w p ACH ABOVE COUNTER HEIGHT FOC FURNISHED BY OWNER SMD SEE MECHANICAL DRAWINGS MFR MANUFACTURER .�-•• ,,,. , I I I I[� �r� J � � � i'' � !�� Z��� F A F F A B O V E F I N I S H E D F L O O R I N S T A L L E D B Y C O N T R A C T O R S M S S H E E T M E T A L S C R E W M I N M I N I M U M �,,;.,,,, I Uy "" -� I� ! O O�� � ALUM ALUMINUM FOS FACE OF STUD SPD SEE PLUMBING DRAWINGS MISC. MISCELLANEOUS . ( � 1 I , y N� � ARCH ARCHITECTURAL,ARCHITECT FOSTL FACE OF$TEEL SPEC SPECIFICATIONS MIW MAL IRON WASHER - J BD BOARD FRP FIBERGLASS REINFORCED PANEL S/S $TAINLE55 STEEL MOD MODULAR ° ! !I I I � � � O p�j� Z BLDG BUILDING FT FOOT OR FEET STD STANDARD MTD MOUNTED ° � � � '� � J U N � � (�I � BLKG BLOCKING FTG FOOTING STL STEEL MTL METAL " � '"` I �� � O Z O�� I �; i� BM BEAM GA GAUGE STS SELF TAPPING SCREW (N) NEW •.,,, � ; �_;�__.; ! J BOT BOTTOM GALV GALVANIZED T&G TONGUE&GROVE NIC NOT IN CONTRACT �--� � BUR BUILT-UP ROOFING GSM GALVANIZED SHEET METAL TOP TOP OF PAVEMENT NOM NOMINAL �"'� �� ` .w`"�"s`YI��YAir� ���r ; = � CENTER LINE GWB GYPSUM WALLBOARD TOF TOP OF FLOOR NTS NOT TO$CALE �,.>.. .� �� � ' CLG CEILING GYP GYPSUM TOS TOP OF SLAB/STEEL OC ON CENTER ' ' _ � �rr .'^.,,. `. r . COL COLUMN H OR HGT HEIGHT TOW TOP OF WALL OD OUTSIDE DIAMETER "°' • 1 `" � , � �-------- -�----------��...�.e �i-i6WN COMP COMPOSITE HB HOSE 816 TS TUBE STEEL PDP POWDER DRIVEN PIN -- - CONT CONTINUOUS HHS HEX HEAD SCREW TYP TYPICAL PH PANIC HARDWARE ' ``.,, ,..„„.�. CPT CARPET HM HOLLOW METAL UNO UNLESS NOTED OTHERWISE C PLATE DBL DOUBLE HORIZ HORIZONTAL VCT VINYL PLF PER LINAL FOOT - ` �, DET DETAIL HVAC HEATING VENTILATION VERT VERTICAL PLAM PLASTIC LAMINATE � z '' ¶-� DIM DIMENSION AIR CONDITIONING W WIDTH PLYWD PLYWOOD ' � DSA DIVISION OF STATE ARCHITECT ID INSIDE DIAMETER W/ WITH PR PAIR • ` DWG DRAWING WD WOOD PSF POUNDS PER SQUARE FOOT � �JO�'"�""` �F � . . , r. ,,_- � • l � � . �. . ( � ,� � F � �� _ _ '� .�� � • ,ri�,ti .� . a _ i��. .r•' ��'.�► �' •i � /� � ',� �� . +..�- ! , .+P�Y:�v�.��G� . y+R .I�"'� _� � , • . ,� J ` _ .t'�. •�R M� �- •�• ��w �' ,,,,.,�„��.,,,..... � =:r � ��!f ` �P � °' � � '` a 4 't � •' ~'� � �``�� ++�. !"��(! t t��i .4 ( ► � � � '�b�� ♦ �,''w' •�..alr���� . I �.�•.fi ��� *�••�' ����� �. � � � f r�,�+��. I�!� � �.�, �� , �`�t�vr'My�,���F a.���+ . � I �'`• � `� s !_�i � .# � � � ' � . . � . ' . . .. ..�...IR F,S ,�...:`Y ). r�'�r,� �"' -- * ' . :� . � f , �!',h �1 ., ��•� ' ' �r 1+e �"�°"�� -. _ ' �tii■�� * +— �� � � � • ` V' �� / _ '��� ±•�,,. �. �V,j °�\ =.e � 1 `, ` ._�_. ... -;; ��•A . \srw�.....� � . � �" A� � `�"Y� �'.. . ..+.___� � . �i�.. �°1 �'�' . �r, � '� . -' + ^ , � � i� � �4t � ��. .w�, � • :'�, �� i ', ' � • • .� �`,%?�i. =..ti.�..._ • � � ��,. • s �✓.� ,-• � ~�"�' r � ; .� �R" .� . i, '•*`, .� �- i, ��� � ,i ,.� . -'— ' •' ��6 ___ ' •. :� '� 1 , ���- --. ��� '�•' �' , ' - - . .., • ad�te,�i�� . , , �_t; •�' .�. I � �� (� � . PRODUCE �_ � �,,�•�.1. � ��li■r... �..n■.r --�- ____ ' _ ?• `�•�( M A R K E T �� ( � � _ r, . � -_ `. ' 1 �� '.�- . ss«.. �� : �s+.,,�"�'�*�'�...r� �•s+ • .. ' �' ' k w_ y'.._ ,ti' ' r_,,�; : . r._.3 <�r_' , ,�, , � _ .,.�,_ . . ,�'"',� � ' ��' '' ���� I �;,¢ �,ly - _.. �t ��� � � '�� �r � 1 ' �. tw� .,�, A�� ��st � ti I 1�_�_� �� .� � +cZ ' 3 `-.. .; , i*� ,,`,'�'� � �� K 4.. .. . �---'� .,,,._� _, . .�� - ._� ' I .r.�� M_, `��� � ' _ : , - ,, _ _ _ � � � . �� � ""�`� • ��� 'HE BACKUP .j� i fr. /_ `. ., � - ;��, � . _...�x...__. �� � . i , � �. � .-, �� �:���'� ' (`'w •V _ � ,,,� . . � � - ,^�.�� ,?.��,,,.�t i,,��-�.�.'��'';y':.»'�f��'..�. �!� r: �.- �y-_' - - - �.,'�� �k� . �'� "11 �� �i_ � � �V '.''�"� �� SI�PLAN ScA_e: = O=T TOTAL f ARKIN6 STALLS= ACCE55IBLE STALLS= 85 3 EXISTING SIDE WALK CONTINIOUS FROM THE ACCESSIBLE PARKING SPACE,MAX SLOPE 5%WITH A MAX CROSS SLOPE OF 2%.NO RAMP NEEDED. �.� ! c� a � �1 BAKERY � '�" -, � � � , �� �" ��� . , I r. �� �.� `� � � y . � 1� '� � `� _ =---.�+� -• � � �.�__�� (N)BACKFLOW PREVENTORS 1)3/4"SERVING THE(E)BAKERY 2)1"SERVING THE(E)PRODUCE STORE � � Yti` � i•t� }•�r � �� � Nen�fac:�re� 'ode`J�n�ber Si_es =rits C�09 '�4'.1.1 :4'1 _._ I I �ye�elC �_514,ft"�- NEW COVER fRASH AREA 1)4"STEEL POST 2)CORIGATED METAL ROOF 3)PAINT COVER TO MATCH(E) 4)(2)EXI51'NG 7'XS'GARBAGE BINS 5)6"CURB BUILDING V V ��8'BLOCK FENCE THERE ARE NO STORM \ DRAINS IN THIS AREA 0 6�_p�� I O �p 2 � 3 O O19'-11" 3 EXISTING METAL GATE AND TRASH AREA Ap����� �: �,C.��Df�—Ob � Ap����;::::;=on ir��.3�,��er .. �����""�� � EXISTING PRODUCE STORE ING TRASH AREA NEW COVER 6'x15-6" ► ���. � � � • ,-��-, , ,-�r-, ,..�r., ,: �%�%%����j/. �i�/�i���/i//i% �/� i� i�L,i �iJL/ .. � � OUTDOOR SALES AREA Scale:1/8"=1'-0" N U1 N ��-���� lil CART STORAGEAREA 3'-6"o O � � �� 0 0 0 �� a� � 3'1 1"X 3'4"34"TALL VEG,FRUIT CART ON WHEELS � 1'X20"34"TALL /EG,FRI,qT ;ART ON WHEELS � FRONT ELEVATION ��Scale: 1/8"=1'-0" ��IGHT ELEVATION � Scale:1/8"=1'-0" NEW COVER TRAS AREA 1)4"STEEL POST 2)CORIGATED ME L ROOF ' 3)PAINT COVER T MATCH(E) o 4)(2)EXISTING 7' S'GARBAGE BINS � 5)6"CURB � �� LEFT ELEVATION � Scale:1/8"=1'-0" ������� �������� �� ���'� Il����� . � � 1 � o � � � �� . ; _ 0 2 � s , � � d � � ° =`` ' z � � m � � � � �: � w c � � � � W � ; ; � d : 1 : ' � _ Z � U �� � �� � r Z C� ��l' � CC Z ��� O � o ��� � � � Z �u m z u N � Q � �� � � � � � c: � �. � � 0 � �Q Q z �w�� � co°L° � _�' � u� Q�� om m s�ow� TI-2.I OFFICE OF COMMUNITY DEVELOPMENT CITY HALL 10300 TORRE AVENUE •CUPERTINO,CA 95014-3255 (408)777-3308 • FAX(408)777-3333 CUPERTINO ADMINISTRATIVE HEARING STAFF REPORT Agenda Item No. Z 'F 3 Agenda Date: Se�tember 12, 2013 Applications: DP-2013-01, ASA-2013-03, ASA-2013-04, TR-2013-12, and TR-2013-32 Applicant/owner: Terry Brown (D.G. and Shirley Long)- 10049 Imperial Avenue Terry Brown (Barbara Kalman, Et al.)-21666-21686 Stevens Creek Boulevard Project Locations: 10049 Imperial Avenue (APN 357-17-013) and 21666-21686 Stevens Creek Blvd. Application Summaries: 10049 Im�erial Avenue 1. Development Permit (DP-2013-01) to allow the demolition of a single-family home and detached garage and allow the construction of a two-story mixed use building with a commercial and medical space and one residential apartment. 2. Architectural and Site Approval Permit (ASA-2013-03) to allow the construction of a new two-story mixed use building with associated site improvements. 3. Tree Removal Permit (TR-2013-12) to allow the transplantation of an 18-inch Coast Live Oak tree and the removal and replacement of a 24-inch diameter Pittosporum tree and two multi-trunk California Pepper trees on the site of a proposed mixed use building. 21666-21686 Stevens Creek Boulevard 4. Architectural and Site Approval Permit(ASA-2013-04) to allow modifications to the parking lot layout to facilitate reciprocal ingress and egress at the Stanley Square Center in the Monta Vista District. 5. Tree Removal Permit (TR-2013-32) to allow the removal and replacement of 4 Flowering Pear trees as part of modifications to the parking lot layout. RECOMMENDATION: Staff recommends that the Director of Community Development approve the Development Permit (DP-2013-01), Architectural and Site Approval Permits (ASA-2013-03 and ASA-2013-04), and Tree Removal Permits (TR-2013-12 and TR-2013-32) per the draft resolutions. DP-2013-01,ASA-2013-03,TR-2013-12 10049 Imperial Avenue September 12,2013 ASA-2013-04 and TR-2013-32 21666-21686 Stevens Creek Boulevard Page 2 PROJECT DATA: 10049 Imperial Avenue 21666-21686 Stevens Creek Blvd General Plan Designation Neighborhood Commercial/Residential (Monta Vista Special Center) Zoning Designation [P (CN, ML, Res 4-12)] Planned Neighborhood Commercial, Light Industrial, and Residential with 4-12 dwellin units er ross acre Desi n Guidelines Monta Vista Desi Guidelines Lot Size 7,187 s . ft. (0.16 acre) 24,375 s . ft. (0.56 acre) Existing use (to be 1 single family home(� 888 sq. ft.) demolished) Proposed use: Mixed Use Residential: 2,276 s . ft. (Inc. ara e:451 s . ft.) Nonresidential: 1,525 s . ft. Commercial 1,000 s . ft. N/A Medical 525 s . ft. Total 3,801 s . ft. Provided Re uired Pro osed Front setback: 5 ft. 5 ft. min. Proposed Side (south) 12 ft. 6 in. No min. setback Proposed Side (north) 10 ft. No min. setback Pro osed Rear setback: 47 ft. No min. Pro osed hei ht 26 ft., two stories 30 ft. max. Auto Parkin Provided Re uired Provided/IZec�uired Residential 2 stalls 2 stalls (2/unit) N/A Commercial 4 stalls 4 stalls (1/250 41 stalls s ft.) Medical 3 stalls 3 stalls (1/175 N/A s ft.) Total: 9 stalls [(7 onsite, 2 9 stalls 41 stalls ([(35 onsite, 6 on- on-street) (see GP street) (see GP Policy 2-24)] Polic 2-24)] Bicycle parking 4 stalls 1 stall No chan e Project Consistenc With: General Plan Yes Zonin Yes Environmental Assessment Categorically Exempt(Section Categorically Exempt 15303) (Section 15301) DP-2013-01, ASA-2013-03,TR-2013-12 10049 Imperial Avenue September 12,2013 ASA-2013-04 and TR-2013-32 21666-21686 Stevens Creek Boulevard Page 3 BACKGROUND: Previous City Approvals The project site at 10049 Imperial Avenue ("Imperial site") was developed with a single-family residence under Santa Clara County's jurisdiction in the 1940s and was annexed into the City in 1980. There are no subsequent City approvals for development on the site. The project site at 21666-21686 Stevens Creek Boulevard ("Stevens Creek site") was also developed under the County's jurisdiction in the 1950s and annexed in 1980. In 2002, a fa�ade remodel of the existing commercial building at the Stevens Creek site was allowed with an Architectural and Site Approval (ASA-2002-02). At that time, the Stevens Creek site was required to record a covenant to allow a reciprocal ingress and egress easement with the Imperial site. . . . Exzstzng Site an A . . . . �. g. �, . , . . , � �� . Surroundings �-- � ��'�•=�:�' , -Rr�N� :�� �" "; �� , , ,, � �� �p���r�►�s��� �� ° � ��,, , �) i�?r'"� ''' ,� - — �+ .. � kr. � The project sites are located ' � V '" , � w' �* �� �.�,a���� ��.. � adjacent to each other � " ° ���,� " ,� � �.- . �,..a P'. ..., . `; !"-� a --�, � ��, , . .. . . . _ �r�., :'«�P t�!`.s 1��;,°. � —i�/ � � �.. with�n the Monta Vista �- � ° � - �' - �,_ ��1i.r. _,_. -:...-. ' . . ,_ , ��,;� �,_ � .__.. �e :w ,.,,, ...,_ . _.-:�--.--,•�,� � ..a Plannin District at the ���' � � ' = �, ' .' �� �� ., g �� � ,. . southwest corner of the M � ��' .�,_ --� �. � - � ������ .� _ ; , �.�►�: co�cn�+�. � =� �. � � � ``���°, � >. -- intersection of Stevens ��� �, r. ��'��'r�� oF�_r� ,�„� ^ �`�'��,k ��� -M .�W.�~—�— 2i6G6-21686 SCB � Creek Boulevard and ;��` _� �� . � _ �' �, ,-. � Im erial Avenue. The sites -0�'' R - � r -•�' ` �``-�3`���s� �°������ .'� '�� �� � �+.� _- ��. �r !� � ,..,il�,w°� ��.�.,�a,',x/ . .._�.__. ..`;:t. - • . •^—�., ;. . . are bounded by mixed ' #�:�' "` `�' ` RIAi. � .~�---=�=-.__ .:"�'��`(`��. °y���,� � ', ;� 1�49 tmperiai Ave .iYYS-,q. .'^M.yl` � commercial-office, -� ?�-��F;,��-�! -�'�x�,� �; � �V Y�:;�;,. _ � . �, .., _ � �� � �'� ,� �� . , :�N� � �:.: � � �,,� �ts�,a� � a, �:r�w industrial, and mixed �ts � _ �'�w'�s.� �, �:': �, �, y..:a �',�.. - , �... � ,. , - .. �H: : �rr .. .z+�,�^^.---=i�+ . .+. ��.. office-residential to the �' ,.��� �� �. � • �►� ,' ��-;..�..,. ,.,, _°i�!�,r..t_ ttuousr��at Th� , rr�., �o �c�� , . west; office and commercial � �, o �n_ � ---- :_ � ��.� ��, ���, o_ �,. �,,., 1, 3; c�►� �t�tnnERCta� ���� uses across Imy�✓�erial �TM �-�.i�r ' ��4���� '�� � "�_ °� 1 .i� r- i. , . . . :��� INDU � �• P, . �� " �CQl��RCIAI,� n '�'� ;� ;''���� Avenue to the east; �� � �s� .. •� *;� � ° �'' �y .. �RE��E1�1T11['�•��� ; ' ^ '"; � ,-"� industrial uses to the south; � �::. ,- ��" -.� �-- �, ,'"� � ��� �����. � � � ,,- ��. .� ,� �� �� � � � -�r � �� - .�.. .. �� ., ,�"�` . - _ - ; � and the Cupertino Post �'�' �`' "�� F' ��`' '° r���' : ��� ..>�.^.�... ..,�'d',r. ..� :� e.l � i ; --�. �._..' � .t' .,. Office across Stevens Creek - �: � •. �_ � '° ����� ^` = �r� �.: Boulevard to the north. Site Vicinity Aerial DISCUSSION: Application Request The applicant, Terry Brown, representing the property owners of the Imperial site, is requesting a Development Permit, Architectural and Site Approval, and Tree Removal Permit for the demolition of an existing single-family residence and construction of a new 3,801 square foot, two-story mixed residential, commercial, and office building with associated tree removals, tree transplantation, and site improvements. The project is requesting an allocation of 1,000 square feet of commercial allocation and 525 square feet of office allocation. No residential allocation is necessary since there is not a net increase in units. This will leave a balance of 5,784 retail DP-2013-01,ASA-2013-03,TR-2013-12 10049 Imperial Avenue September 12,2013 ASA-2013-04 and TR-2013-32 21666-21686 Stevens Creek Boulevard Page 4 commercial square feet in the Monta Vista Planning Area. Currently, there is no office development allocation available within the Monta Vista Planning Area. However, the General Plan allows the transfer of allocation from one geographical area to another if no significant environmental impacts are associated with the project. Since there are no significant environmental impacts with the project, staff is proposing that the requested office allocation (525 square feet) be drawn from the office allocation available within the Heart of the City Planning Area, which would leave a balance of 17,113 office allocation in Heart of the City. The applicant is also representing the property owners of the adjoining Stevens Creek site to the north to request an Architectural and Site Approval permit and Tree Removal Permit to facilitate a shared access driveway with the Imperial site which require some modifications to the parking lot layout of the Stanley Square Shopping Center. The project is being reviewed at an administrative hearing by the Director of Community Development since the Municipal Code establishes the approval authority for minor Development Permits and Architectural and Site Approval permits as the Hearing Officer of the administrative hearing. Site and Off-Site Improvements Site and off-site improvements proposed are summarized as follows: 10049 Imperial Avenue • Two-way driveway connection to the Stevens Creek site • Public sidewalk, landscaping, tree, and street furniture enhancements along the street frontage • Parking lot in the rear designed to maximize parking capacity and to enhance efficiency, landscaping, onsite permeability, and pedestrian safety • One-way driveway along the south property line to connect Imperial Avenue to the rear parking lot in anticipation of a future shared two-way driveway with the property to the south • Walkway connecting the public sidewalk to the rear parking lot � Bicycle parking facilities • Detached trash enclosure • Pedestrian-scale lighting along walkways, building lights, and parking lot lighting throughout the project site • Parallel parking stall and replacement of curb and gutter along street frontage 21666-21686 Stevens Creek Boulevard • Two-way driveway connection to the Imperial site • Re-orientation of diagonal stalls in south parking aisle to perpendicular stalls • Widening south parking aisle and driveway approach to allow two-way vehicular access • Pedestrian-scale pole light, consistent with the Monta Vista Design Guidelines • Extended parking lot landscaping buffers with trees • Parallel parking stall and replacement of curb and gutter along south street frontage DP-2013-01,ASA-2013-03,TR-2013-12 10049 Imperial Avenue September 12,2013 ASA-2013-04 and TR-2013-32 21666-21686 Stevens Creek Boulevard Page 5 • Removal of existing fence along the south property line in order to allow access through both sites Conformance to General Plan The project sites are within the Monta Vista Planning District identified in the General Plan. The project conforms to the General Plan use, height, and density regulations. In addition, the project meets the following General Plan Policies: Polic�2-24: Monta Vista Retain and enhance Monta Vista as a residential, commercial, and industrial node, with adequate pedestrian and bicycle access. The commercial district should serve as a neighborhood commercial center for Monta Vista and its adjoining neighborhoods. Mixed-use with residential is encouraged. The proposed mixed use building at the Imperial site consists of a three-bedroom residential apartment unit on the second floor with neighborhood-serving commercial and office uses on the ground floor. The project is similar to other recently approved mixed use projects in Monta Vista. Adequate pedestrian and bicycle access is provided through public sidewalks along the street and walkways with a public access easement through the project site and bicycle parking along the public right-of-way. The project is also consistent with the Monta Vista Design Guidelines, explained later in the report. Polic�2-24, Desi�,n Element 1: Interconnected Access Individual properties shall have interconnected pedestrian and vehicle access and shared parking. The project will provide interconnected pedestrian and vehicle access between the two sites. In addition, the conditions of approval require reciprocal ingress/egress easements to be recorded on the properties to allow future connections when adjoining sites redevelop. A formal shared parking agreement is not required since both sites provide adequate parking onsite and directly in front of the site in conformance with the Parking Ordinance and the General Plan. Policy 2-24, DesiQn Element 2: Parkin� Commercial properties or commercial portions of properties may rely on public parking on Pasadena and Imperial Avenues to meet their off-street parking needs within the area bounded by Granada Avenue, Stevens Creek Boulevard, Orange Avenue, and the Union Pacific right-of-way. The project relies on public parking for a small portion of the required parking supply. The project proposes three on-street parking stalls. Polic�2-24, Desi�n Element 3: Storefront A��earance Commercial and office buildings shall include a storefront appearance to the public street, and shall not be sepnrated from the public sidewalk b� extensive landscaping or changes in elevation. Office buildings shall be designed to accommodate future entrances from the sidewalk for future retail uses. DP-2013-01,ASA-2013-03,TR-2013-12 10049 Imperial Avenue September 12,2013 ASA-2013-04 and TR-2013-32 21666-21686 Stevens Creek Boulevard Page 6 The proposed mixed use building provides a storefront appearance along Imperial Avenue with a pedestrian-oriented setback, entry, and storefront bays consistent with the Monta Vista Design Guidelines. Each tenant space has pedestrian entrances/access from the public sidewalk. Conformance to Monta Vista Design Guidelines The Monta Vista Design Guidelines provide development standards and design guidelines for various land uses in the Monta Vista Special Planning District. The project conforms to the Monta Vista Design Guidelines as follows: • Two-story structures promoting a well defined streetscape: The proposed mixed use building is two-stories high and provides a sense of enclosure along the street. • Building placement: The proposed mixed use building meets the specified setbacks in the guidelines. • Architectural Style: The proposed building architecture is consistent with the design guidelines in that the proposed building materials, colors, and building forms are in keeping with the standards recommended. In addition, the proposed building is compatible in mass and scale with the predominant neighborhood pattern. The City's Architectural Consultant has reviewed the building and supports the design. Specific comments from the architectural consultant have been addressed and incorporated into the proposed design. • Landscaping: Both project sites propose landscaping that is consistent with the overall informal landscape character of the design guidelines. The existing mature oak tree at the rear of the Imperial site is proposed for relocation and retention. Broad-crowned canopy trees are proposed to shade parking areas. Flowering ornamental trees are also provided throughout both sites. • Street Sections: The project provides a detached public sidewalk with a parkway planter strip to accommodate street trees and groundcover, consistent with the design guidelines. • Furniture, Fences F�Accessories: The project provides street furniture along the street frontage of the proposed mixed use building, including a bench, trash receptacles, and bicycle parking. • Lighting: The project proposes a new pedestrian-scale light pole to illuminate the public sidewalk, consistent with Monta Vista Design Guidelines. Low-level lighting is proposed in parking areas and along pedestrian walkways directed to preclude glare onto adjacent properties. • Trash Enclosure Screening: The Imperial site provides a new trash enclosure, consistent with the City's Trash Enclosure Guidelines, designed and located to the satisfaction of the City's Environmental Programs Manager and Recology. The proposed trash enclosure features decorative wood fencing with an overhead trellis in order to screen it from the public right- of-way. There is an existing trash enclosure at the Stevens Creek site that was constructed in DP-2013-01,ASA-2013-03,TR-2013-12 10049 Imperial Avenue September 12,2013 ASA-2013-04 and TR-2013-32 21666-21686 Stevens Creek Boulevard Page 7 conjunction with the previously approved site enhancements in 2002. No changes have been proposed or required for this trash enclosure. Circulation The project proposes to connect both sites with a two-way driveway connection. The existing diagonal stalls at the Stevens Creek site are proposed to be re-oriented to perpendicular stalls in order to accommodate the connecHon and maximize parking supply. The stall re-orientation also allows two-way access on the south drive aisle of the parking lot and improved circulation on the Stevens Creek site. Reciprocal ingress/egress easements will be required for the project connection. Additionally, the property owners of both sites will be required to enter into a maintenance agreement for the common driveway and parking lot improvements. The existing driveway on the south side of the Imperial site is proposed to be replaced with a one-way paver driveway designed to be widened to a shared two-way driveway when the adjoining site at 10051-10053 Imperial Avenue redevelops. The project is required to record an easement to allow future reciprocal access along this driveway, as well as an easement to connect the rear drive aisle to the 10051-10053 Imperial Avenue site. Parking The parking provided on the two sites satisfies the City's parking requirements. Parking provided includes 35 stalls on the Stevens Creek site, 7 stalls on the Imperial site, two parallel stalls on-street in front of the Imperial site, and six stalls (5 existing diagonal and 1 new parallel) provided on-street along the Stevens Creek site. As mentioned earlier in the report, General Plan Policy 2-24 allows credit for street parking for commercial uses. The intended tenants of the new mixed use building are a commercial and medical office tenant. A condition of approval restricts the future uses to what is currently proposed, unless a parking study is submitted at the applicant's expense demonstrating adequate parking supply. The required residential parking for the Imperial site is provided in a two-car garage. Tree Removals The project proposes to remove seven protected trees within the proposed areas of work (three at the Imperial site and four at the Stevens Creek site). The tree removals proposed are 1- Pittosporum, 2- California Pepper (10049 Imperial Avenue) and 4- Flowering Pear (21666-21686 Stevens Creek Boulevard). None of the trees removed are specimen trees, since they are smaller than 10 inches in diameter and/or not on the City's Specimen Tree list. The City's Consulting Arborist reviewed and concurred with the project's removal request(Attachment 2). In order to mitigate the removal of the protected trees, eight 24-inch box Flowering Pear trees and two 24-inch box Trident Maple trees along the frontage and in both parking lots are proposed to be planted consistent with the Protected Tree Ordinance. Staff supports the tree removals since they allow for a safer and more efficient circulation plan. Further, the proposed replacement trees will visually enhance the site. The final location of the tree replacements will be reviewed by staff in conjunction with the building permit review. DP-2013-01,ASA-2013-03,TR-2013-12 10049 Imperial Avenue September 12,2013 ASA-2013-04 and TR-2013-32 21666-21686 Stevens Creek Boulevard Page 8 'The proposed parking lot improvements at the Imperial site will require the relocation of an existing 18" Coast Live Oak tree. This is considered a specimen tree per the Protected Tree Ordinance. The City's Consulting Arborist has reviewed the proposed transplantation and concurs that the tree can be successfully transplanted (Attachment 3). A condition of approval has been added to ensure that the services of the City's Consulting Arborist are retained to recommend specific transplantation measures prior to building permit issuance and to confirm the tree's good health prior to final occupancy. OTHER DEPARTMENT/AGENCY REVIEW The City's Public Works Department; Building Division; the Santa Clara County Fire Department; Cupertino Sanitary District; and Recology reviewed the request and have no objections to the project. Their pre-hearing comments have been incorporated as conditions of approval in the draft resolutions. ENVIRONMENTAL ASSESSMENT 'The project at the Imperial site is categorically exempt from the California Environmental Quality Act (CEQA) per section 15303 (New Construction) of the CEQA Guidelines because it applies to a mixed residential and commercial building not exceeding 10,000 square feet. In addition, a Phase I Environmental Site Assessment (ESA) was conducted for the property. The Phase I ESA concluded that no further environmental investigations are needed given that no recognized adverse environmental conditions were identified. The project at the Stevens Creek site is also categorically exempt per secdon 15301 (Existing Facilities) since it involves minor alterations to an existing developed site. PUBLIC NOTICING &OUTREACH The following table is a brief summary of the noticing done for this project: Notice of Public Hearin ,Site Notice&Legal Ad A enda • Site Signage • Posted on the City's official notice (14 days prior to the hearing) bulletin board (one week prior to the • 48 notices mailed to property owners within hearing) 300 feet of the project site - 10049 Imperial • Posted on the City of Cupertino's Web Avenue (10 days prior to the hearing) site (one week prior to the hearing) • 48 notices mailed to property owners within 300 feet of the project site — 21666-21686 Stevens Creek Boulevard (10 days prior to the hearin ) The City sent out notices to property owners within 300 feet of the project sites. While only adjacent noticing is required for the project proposed at the Stevens Creek site, noticing was sent to property owners within 300 feet of the site since the project is being proposed at the same time as the project on the Imperial site. No public comments were received at the time of staff report production. DP-2013-01,ASA-2013-03,TR-2013-12 10049 Imperial Avenue September 12,2013 ASA-2013-04 and TR-2013-32 21666-21686 Stevens Creek Boulevard Page 9 PERMIT STREAMLINING ACT This project is subject to the Permit Streamlining Act(Government Code Section 65920—65964). The City has complied with the deadlines found in the Permit Streamlining Act. Project Received: March 22, 2013 Deemed Incomplete:Apri122, 2013 and August 7, 2013 Deemed Complete:August 29, 2013 The City has 60 days (until October 29, 2013) to make a decision on the project since this project is Categorically Exempt from CEQA. The Director of Community Development's decision on this project is final unless appealed to the Planning Commission within 14 calendar days of the decision. CONCLUSION Staff recommends approval of the Development Permit, Architectural and Site Approvals and Tree Removals, since the plans and conditions of approval address all concerns related to the proposed project. Additionally, all of the findings for approval of the proposed project, consistent with Chapter 19.156, 19.168, and 14.18 of the Cupertino Municipal Code, may be made. Submitted by: George Schroeder, Associate Planner Attachments 1 -Draft Resolutions � 2—Consulting arborist's tree removal report 3—Consulting arborist's tree transplantation report Plan Set DP-2013-01 CITY OF CUPERTINO 10300 Torre Avenue Cupertino, California 95014 RESOLUTION NO. 22 OF THE ADMINISTRATIVE HEARING MEETING OF THE CITY OF CUPERTINO TO ALLOW THE DEMOLITION OF A SINGLE-FAMILY HOME AND DETACHED GARAGE AND ALLOW THE CONSTRUCTION OF A MIXED USE BUILDING WITH A COMMERCIAL AND MEDICAL SPACE AND ONE RESIDENTIAL APARTMENT AT 10049 IMPERIAL AVENUE SECTION I: PROJECT DESCRIPTION&RECITALS Application No.: DP-2013-01 Applicant: Terry Brown Property Owner: D.G. and Shirley Long Location: 10049 Imperial Avenue (APN 357-17-013) Subject: Development Permit to allow the construction of a new mixed use building. WHEREAS, the Administrative Hearing Officer of the City of Cupertino received an application for a Development Permit as described in Section I. of this Resolution; and WHEREAS, the necessary public notices have been given as required by the Procedural Ordinance of the City of Cupertino, and the Administrative Hearing Officer held a public hearing on September 12, 2013 in regard to the application; and NOW, THEREFORE, BE IT RESOLVED: After careful consideration of the maps, facts, exhibits, testimony and other evidence submitted in this matter, the Administrative Hearing Officer hereby approves Application no. DP-2013-01 based upon the findings described in Section II of this resolution, the public hearing record, and the minutes of the Administrative Hearing meeting of September 12, 2013, and subject to the conditions specified in Section III of this resolution. SECTION II: FINDINGS: 1. T'he proposed development and/or use, at the proposed location, will not be detrimental or injurious to property or improvements in the vicinity, and will not be detrimental to the public health, safety, general welfare, or convenience; The proposed mixed use building will not be detrimental or injurious to property or improvements in the vicinity, and will not be detrimental to the public health, safety, general welfare, or convenience because it is located within a mixed use light industrial, neighborhood commercial, and residential district, which includes a variety of different land uses similar to the one proposed. The City has approved other similar mixed use projects in the neighborhood which is consistent with the City's General Plan Policy 2-24 for Monta Vista. Resolution No.22 DP-2013-01 September 12,2013 2. The proposed development and/or use will be located and conducted in a manner in accord with the Cupertino Comprehensive General Plan,underlying zoning regulations, and the purpose of this title and complies with the California Environmental Quality Act(CEQA). The proposed mixed use building is consistent with and will be conducted in a manner in accord with the General Plan, zoning ordinance, and CEQA. For example, the project will be required to allow/provide connections with adjoining sites (GP Policy 2-2 and 2-24), provide a storefront appearance (GP Policy 2-24), and provide a safe parking lot (GP Policy 4-1). The conditions of approval contained in this resolution further reduce the likelihood of adverse impacts to surrounding properties. SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY DEVELOPMENT DEPT. Planning Division: 1. APPROVED EXHIBITS Approval is based on plan sets received on August 23, 2013, titled "A Mixed Use Project with all new Construction for 10049 Imperial Ave., Cupertino, CA, 95014", consisting of five sheets labeled "Sheet No. 1 to Sheet No. 5 " and titled "Imperial Ave. Street Elevation,"consisting of twelve sheets labeled "L1.0 to L.4.0 and Sheet 1 to Sheet 6"drawn by Ray Rooker Architect, Reed Associates Landscape Architecture, and Nordic Engineering Inc. except as may be amended by conditions in this resolution. 2. ACCURACY OF PROJECT PLANS The applicant/property owner is responsible to verify all pertinent property data including but not limited to property boundary locations, building setbacks, property size, building square footage, any relevant easements and/or construction records. Any misrepresentation of any property data may invalidate this approval and may require additional review. 3. ANNOTATION OF THE CONDITIONS OF APPROVAL The conditions of approval set forth shall be incorporated into and annotated on the first page of the building plans. 4. CONCURRENT APPROVAL CONDITIONS The conditions of approval contained in file nos. ASA-2013-03 and TR-2013-12 shall be applicable to this approval. 5. PREVIOUS CONDITIONS OF APPROVAL The following previous conditions of approval for the project site shall remain in effect: Z-1980-40 • All conditions 6. DEVELOPMENT APPROVAL AND PROJECT AMENDMENTS Development Permit approval is granted to allow the demolition of an existing single-family home and detached garage and the construction of a 3,801 square foot two-story mixed use building with commercial uses, a medical use, and one residential apartment. Allowed uses include Neighborhood Commercial uses that serve primarily the residents of adjacent neighborhoods. This includes, but is not limited to, retail activities, personal services, and limited commercial and medical offices. Future uses will be determined using the City's Parking Ordinance. Resolution No.22 DP-2013-01 September 12,2013 A separate conditional use permit shall be required for commercial and office uses not considered neighborhood commercial by the Director of Community Development. Development intensity shall be regulated by conditional use permit review. The Director of Community Development shall review amendments to the project considered major. 7. DEVELOPMENT ALLOCATION The applicant shall receive an allocation of 1,000 square feet of commercial allocation from the Monta Vista General Plan area and 525 square feet of office allocation from the Heart of the City General Plan area. 8. TOTAL AVAILABLE PARKING There shall be a minimum of seven (7) available parking stalls onsite. Two (2) additional on-street stall directly in front of the site may be used for the onsite parking requirement per the General Plan. Any proposed intensification of the approved uses shown on the development plans (including,but not limited to, additional medical office space, child care, food uses) will require City review and approval and potential additional studies at the applicant's expense. 9. PARKWAY AND SIDEWALK WIDTH The construction plans shall include a 6 foot wide parkway along the curb and a 5 foot wide public sidewalk along the project frontage, beginning south of the southern driveway on 21666-21686 Stevens Creek Boulevard (APN 357-17-012). The final details shall be reviewed by the Director of Community Development in conjunction with the Director of Public Works �rior to issuance of building perxnits. 10. BELOW MARKET RATE HOUSING PROGRAM MITIGATION FEES The applicant shall participate in the City's Below Market Rate (BMR) Housing Program by paying the housing mitigation fees as per the Housing Mitigation Manual. The estimated mitigation fee for this project is $8,479 based on the 2013-2014 fiscal year rate of $5.56 per square foot of net commercial/office addition (1,525 square feet). The fees shall be paid vrior to issuance of buildin� nermrts• 11. INGRESS/EGRESS EASEMENTS The property owner shall record an appropriate deed restriction and covenant running with the land, subject to approval of the City Attorney, providing for vehicular and pedestrian reciprocal ingress and egress easements to adjoining parcels at 10051-10053 Imperial Avenue (APN 357-17-014) and 10052-10056 Pasadena Avenue (APN 357-17-035), to be implemented at such time that the City can require the same of adjacent property owners. In addition, the property owner shall record an appropriate deed restriction for necessary vehicular and pedestrian reciprocal ingress and egress, subject to approval of the City Attorney, to and from 21666-21686 Stevens Creek Boulevard (APN 357-17-012). The easements shall be recorded prior to final occu�ancy of site�ermits. 12. PUBLIC PEDESTRIAN ACCESS EASEMENT The property owner shall record an appropriate deed restriction, subject to approval of the City Attorney, for a public pedestrian access easement through the interior pedestrian path(s). The easement shall be recorded prior to final occu�anc�of site�ermits. Resolution No.22 DP-2013-01 September 12,2013 13. PARKING EASEMENT The property owner shall record an appropriate deed restriction and covenant running with the land, subject to approval of the City Attorney, allowing parking access on the northern portion of the property for 21666-21686 Stevens Creek Boulevard (APN 357-17-012). The easement shall be recorded �rior to final occupancv of site�ermits. 14. SHARED ACCESS DRIVEWAY The proposed shared access driveway between the project site and 21666-21686 Stevens Creek Boulevard (APN 357-17-012) shall be fully installed and constructed to the satisfaction of the Public Works Director and Community Development Director prior to the issuance of final occupancy of site�ermits. 15. PARKING LOT MAINTENANCE AGREEMENT/MANAGEMENT PLAN Prior to final occupanc�, the applicant shall record a parking lot maintenance agreement and management plan, subject to the approval of the City Attorney. This shall include, but not be limited to, parking easement area, assignment of parking stalls, maintenance of landscaping, stall striping, surfacing, and stalls that straddle the property at 21666-21686 Stevens Creek Boulevard (APN 357- 17-012). 16. PARKING LOT DIRECTIONAL SIGNAGE Prior to issuance of buildin��ermits, the applicant shall work with staff to consider the following parking lot directional signage to be installed �rior to final occu�anc�: a. Speed bumps and/or speed limit signage b. Directional/informational signs c. Signage indicating "Exit Only" or "Do Not Enter" at the rear parking lot for the driveway at Imperial Avenue d. Transpose directional arrows on the parking lot surface 17. MAIN BUILDING ENTRANCE The main building entrance shall face Imperial Avenue. The entrance doors and storefront are to be kept open and free of any obstructions. No more than 25% of each storefront window bay may be obstructed with signage or other interior items. Boarding, closure, shelves, permanent walls, opaque painting/material of windows, and other storefront obstructions are not permitted. 18. SIGNAGE Signage is not approved with this application. Signage shall conforxn to the City Sign Ordinance (Chapter 19.104 of the Cupertino Municipal Code). 19. FINAL LIGHTING PLAN All new lighting must conform to the standards in the Parking Ordinance (Chapter 19.124) and General Commercial Ordinance (Chapter 19.60), and the final lighting plan (including a detailed photometric plan) shall be reviewed and approved by the Community Development Director �rior to buildin� permit issuance. Prior to final occu�ancv, a licensed lighting consultant shall confirm that the lighting is in compliance with the City's standards. Resolution No.22 DP-2013-01 September 12,2013 20. SCREENING All mechanical and other equipment on the building or on the site shall be screened so they are not visible from public street areas or adjoining developments. Screening materials/colors shall match building features and materials. The height of the screening shall be taller than the height of the mechanical equipment that it is designed to screen. The location of equipment and necessary screening shall be reviewed and approved by the Director of Community Development prior to issuance of building permits. 21. TRANSFORMERS Electrical transformers, telephone cabinets and similar equipment shall be placed in underground vaults. The developer must receive written approval from both the Public Works Department and the Community Development Department prior to installation of any above ground equipment. Should above ground equipment be permitted by the City, equipment and enclosures shall be screened with fencing and landscaping such that said equipment is not visible from public street areas, as determined by the Community Development Department. 22. UT'ILITY STRUCT'URE PLAN Prior to issuance of buildin��ermits, the applicant shall work with staff to provide a detailed utility plan to demonstrate screening or undergrounding of all new utlity structures [including, but not limited to backflow preventers (BFP), fire department connections (FDC), post-indicator valves (PIV), and gas meters] to the satisfaction of the Director of Community Development, Public Works, Fire Department, and applicable utility agencies. 23. TREE PROTECTION The existing trees to remain shall be protected during construction per the City's Protected Tree Ordinance (Chapter 14.18 of the municipal code). The City's standard tree protection measures shall be listed on the plans, and protective fencing shall be installed around the trees to remain rin or to issuance of building �ermits. A report ascertaining the good health of these trees shall be provided prior to issuance of final occu�anc�. 24. LANDSCAPE PROJECT SUBMITTAL Prior to issuance of building permits, the applicant shall submit a full landscape project submittal per section 14.15.040 of the Landscaping Ordinance. The Water-Efficient Design Checklist (Appendix A of Chapter 14.15), Landscape and Irrigation Design Plans, and Water Budget Calculations shall be reviewed and approved to the satisfaction of the Director of Community Development prior to issuance of building permits. 25. LANDSCAPE INSTALLATION REPORT A landscape installation audit shall be conducted by a certified landscape professional after the landscaping and irrigation system have been installed. 'The findings of the assessment shall be consolidated into a landscape installation report. The landscape installation report shall include, but is not limited to: inspection to confirm that the landscaping and irrigation system are installed as specified in the landscape and irrigation design plan, system tune-up, system test with distribution uniformity, reporting overspray or run-off that causes overland flow, and preparation of an irrigation schedule. Resolution No.22 DP-2013-01 September 12,2013 The landscape installation report shall include the following statement: "The landscape and irrigation system have been installed as specified in the landscape and irrigation design plan and complies with the criteria of the ordinance and the permit." 26. LANDSCAPE AND IRRIGATION MAINTENANCE A maintenance schedule shall be established and submitted to the Director of Community Development or his/her designee, either with the landscape application package, with the landscape installation report, or any time before the landscape installation report is submitted. a) Schedules should take into account water requirements for the plant establishment period and water requirements for established landscapes. b) Maintenance shall include, but not be limited to the following: routine inspection; pressure testing, adjustment and repair of the irrigation system; aerating and de-thatching turf areas; replenishing mulch; fertilizing; pruning; replanting of failed plants; weeding; pest control; and removing obstructions to emission devices. c) Failed plants shall be replaced with the same or functionally equivalent plants that may be size- adjusted as appropriate for the stage of growth of the overall installation. Failing plants shall either be replaced or be revived through appropriate adjustxnents in water, nutrients, pest control or other factors as recommended by a landscaping professional. 27. SOIL ANALYSIS REPORT A soils analysis report shall document the various characteristics of the soil (e.g. texture, infiltration rate, pH, soluble salt content, percent organic matter, etc) and provide recommendations for amendments as appropriate to optimize the productivity and water efficiency of the soil. The soil analysis report shall be made available to the professionals preparing the landscape and irrigation design plans in a timely manner either before or during the design process. A copy of the soils analysis report shall be submitted to the Director of Community Development as part of the landscape documentation package. 28. TRASH AND DELIVERY ACTIVITIES A detailed refuse and truck delivery plan shall be prepared by the applicant �rior to issuance of building permits. The plan shall include,but not be limited to the following: a. Location and design of trash facilities (i.e. trash enclosures and receptacles). Trash enclosures shall provide ample space to include trash, recycling, food waste, and waste receptacles along with a tallow bin. b. Quantity of trash receptacles. c. Primary and alternative truck routes. d. Signage for parking stalls displaced during pick-up and delivery hours (if applicable). e. Trash pick-up schedule (shall not take place during peak business hours) f. Loading areas (with signage/markings restricting parking in these areas d uring loading times) g. Delivery hours (shall not take place during peak business hours) All trash facilities must be screened and enclosed to the satisfaction of the Public Works Department. The final plan shall be submitted to the City and the City's refuse service for review and approval prior to issuance of building permits. Resolution No.22 DP-2013-01 September 12,2013 29. CONSTRUCTION HOURS Construction activities shall be limited to Monday through Friday, 7 a.m. to 8 p.m. and Saturday and Sunday, 9 a.m. to 6 p.m. Construction activities are not allowed on holidays. The developer shall be responsible for educating all contractors and subcontractors of said construction restrictions. Rules and regulation pertaining to all construction activities and lixnitations identified in this permit, along with the name and telephone number of a developer appointed disturbance coordinator, shall be posted in a prominent location at the entrance to the job site. 30. DEMOLITION REQUIREMENTS All demolished building and site materials shall be recycled to the maximum extent feasible subject to the Building Official. The applicant shall provide evidence that materials were recycled prior to issuance of final demolition permits. 31. DUST CONTROL The following construction practices shall be implemented during all phases of construction for the proposed project to prevent visible dust emissions from leaving the site: a. Water all active construction areas at least twice daily and more often during windy periods to prevent visible dust from leaving the site; active areas adjacent to windy periods; active areas adjacent to existing land uses shall be kept damp at all times, or shall be treated with non-toxic stabilizers or dust palliatives. b. Cover all trucks hauling soil, sand, and other loose materials or require all trucks to maintain at least 2 feet of freeboard; c. Pave, apply water at least three times daily, or apply (non-toxic) soil stabilizers on all unpaved access roads, parking areas and staging areas at construction sites. d. Sweep streets daily, or more often if necessary (preferably with water sweepers) if visible soil material is carried onto adjacent public streets. e. The applicant shall incorporate the City's construction best management practices into the building permit plan set. 32. NOISE MITIGATION MEASURES The project and retail operations shall comply with the City's Community Noise Control Ordinance (Chapter 10.48 of the CMC). In addition, the following mitigation measures shall be taken in order to reduce noise event impacts to nearby receptor areas: a. The contractor shall use "new technology" power construction equipment with state-of-the-art noise shielding and muffling devices. All intemal combustion engines used on the project site shall be equipped with adequate mufflers and shall be in good mechanical condition to minimize noise created by faulty or poor maintained engines or other components. b. Locate stationary noise generating equipment as far as possible from sensitive receptors. Staging areas shall be located a minimum of 200 feet from noise sensitive receptors, such as residential uses.Unnecessary idling of machines when not in use shall be prohibited. c. The developer will implement a Construction Management Plan approved by the Community Development Director and Director of Public Works to minimize impacts on the surrounding sensitive land uses to the fullest extent possible. d. Temporary plywood enclosures shall be erected around stationary equipment that produces excessive noise at nearby receptors Resolution No.22 DP-2013-01 September 12,2013 e. Good maintenance and lubrication procedures shall be used to reduce operating noise. f. All construction equipment shall conform to the following standards: 1) no individual device produces a noise level more than 87 dBA at a distance of 25 feet; or 2) the noise level on any nearby property does not exceed eighty dBA (Cupertino Municipal Code Section 10.48.053). g. Equip all internal combustion engine driven equipment with intake and exhaust mufflers that are in good condition and appropriate for the equipment. h. Noise from construction workers' radios shall be controlled to a point that it is not audible at existing residences bordering the project site. i. Notify all adjacent businesses, residences, and other noise-sensitive land uses of the construction schedule in writing. 33. PRE-CONSTRUCTION MEETING AND CONSTRUCTION MANAGEMENT PLAN Prior to commencement of construction activities, the applicant shall arrange for a pre-construction meeting with the pertinent departments (including, but not limited to, Building, Planning, Public Works, Santa Clara County Fire Department) to review an applicant-prepared construction management plan including,but not limited to: a. Plan for compliance with conditions of approval b. Plan for public access during work in the public right-of-way c. Construction staging area d. Construction schedule and hours e. Construction phasing plan, if any f. Contractor parking area g. Tree preservation/protection plan h. Site dust, noise and storm run-off management plan i. Emergency/complaint and construction site manager contacts 34. CONSULTATION WITH OTHER DEPARTMENTS The applicant is responsible to consult with other departments and/or agencies with regard to the proposed project for additional conditions and requirements. Any misrepresentation of any submitted data may invalidate an approval by the Community Development Dep artment. 35. INDEMNIFICATION To the extent permitted by law, the Applicant shall indemnify and hold harmless the City, its City Council, its officers, employees and agents (the "indemnified parties") from and against any claim, action, or proceeding brought by a third party against the indemnified parties and the applicant to attack, set aside, or void this ordinance or any permit or approval authorized hereby for the project, including (without limitation) reimbursing the City its actual attorneys' fees and costs incurred in defense of the litigation. The City may, in its sole discretion, elect to defend any such action with attorneys of its choice. 36. NOTICE OF FEES DEDICATIONS, RESERVATIONS OR OTHER EXACTIONS The Conditions of Project Approval set forth herein may include certain fees, dedication requirements, reservation requirements, and other exactions. Pursuant to Government Code Section 66020(d) (1), these Conditions constitute written notice of a statement of the amount of such fees, and a description of the dedications, reservations, and other exactions. You are hereby further notified that the 90-day approval period in which you may protest these fees, dedications, Resolution No.22 DP-2013-01 September 12,2013 reservations, and other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest within this 90-day period complying with all of the requirements of Section 66020, you will be legally barred from later challenging such exactions. Building Division: 37. CONSTRUCTION PLAN SET REVISIONS/INFORMATION Prior to issuance of building permits, the construction plans shall indicate and/or clarify the following information: a. Minimum accessible parking dimensions are 8 feet by 18 feet per stall and S feet by 18 feet for van loading area. Entire accessible parking and loading area is to be 2%or less cross slope. Indicate an accessible path of access from the parking lot to the building and to the public right of way. Each business must be accessible. b. Fire sprinklers are required. SECTION IV: CONDITIONS ADMINISTERED BY THE PUBLIC WORKS DEPARTMENT 1. OFF-SITE PARKING Use of Public Right of way for private parking requirements is permitted within certain areas in Monta Vista, as indicated in the Monta Vista Specific Plan. ADA Accessible parking stalls are required to be located on-site, in order to maximize public parking spaces. 2. STREET WIDENING Public street widening and dedications shall be provided in accordance with City Standards and specifications and as required by the City Engineer. 3. CURB AND GUTTER IMPROVEMENTS Curbs and gutters, sidewalks and related structures shall be installed in accordance with grades and standards as specified by the City Engineer. 4. PEDESTRIAN AND BICYCLE IMPROVEMENTS Developer shall provide pedestrian and bicycle related improvements consistent with the Cupertino Bicycle Transportation Plan and the Pedestrian Transportation Guidelines, and as approved by the City Engineer. 5. BICYCLE PARKING Developer shall provide bicycle parking consistent with the City's requirements to the satisfaction of the City Engineer. 6. STREET LIGHTING INSTALLATION Street lighting shall be installed and shall be as approved by the City Engineer. Lighting fixtures shall be positioned so as to preclude glare and other forms of visual interference to adjoining properties, and shall be no higher than the maximum height permitted by the zone in which the site is located. 7. STREET TREES Street trees shall be planted within the Public Right of Way to the satisfaction of the City Engineer and shall be of a type approved by the City in accordance with Ordinance No. 125. Resolution No.22 DP-2013-01 September 12,2013 8. GRADING Grading shall be as approved and required by the City Engineer in accordance with Chapter 16.08 of the Cupertino Municipal Code. 401 Certifications and 404 permits maybe required. Please contact Army Corp of Engineers and/or Regional Water Quality Control Board as appropriate. 9. DRAINAGE Drainage shall be provided to the satisfaction of the City Engineer. Hydrology and pre- and post- development hydraulic calculations must be provided to indicate whether additional storm water control measures are to be constructed or renovated. The storm drain system may include, but is not limited to, subsurface storage of peak stormwater flows (as needed), bioretention basins, vegetated swales, and hydrodynamic separators to reduce the amount of runoff from the site and improve water quality. The storm drain system shall be designed to detain water on-site (e.g., via buried pipes, retention systems or other approved systems and improvements) as necessary to avoid an increase of the one percent flood water surface elevation to the satisfaction of the City Engineer. Any storm water overflows or surface sheeting should be directed away from neighboring private properties and to the public right of way as much as reason ably possible. 10. BEST MANAGEMENT PRACTICES Utilize Best Management Practices (BMPs), as required by the State Water Resources Control Board, for construction activity, which disturbs soil. BMP plans shall be included in grading and street improvement plans. 11. NPDES CONSTRUCTION GENERAL PERMIT When and where it is required by the State Water Resources Control Board (SWRCB), the developer must obtain a Notice of Intent (NOI) from the SWRCB, which encompasses preparation of a Storm Water Pollution Prevention Plan(SWPPP),use of construction Best Management Practices (BMPs) to control storxn water runoff quality, and BMP inspection and maintenance. 12. C.3 REQUIREMENTS C.3 regulated improvements are required for all projects creating and/or replacing 10,000 S.F. or more of impervious surface, or 5,000 S.F. of uncovered parking lot or restaurant use (collectively over the entire project site). The developer shall reserve a minimum of 4% of developable surface area for the placement of low impact development measures, for storm water treatment, on the tentative map, unless an alternative storm water treatment plan, that satisfies C.3 requirements, is approved by the City Engineer. The developer must include the use and maintenance of site design, source control and storm water treatment Best Management Practices (BMPs), which must be designed per approved numeric sizing criteria. A Storm Water Management Plan, Storm Water Facilities Easement Agreement, Storm Water Facilities Operation and Maintenance Agreement, and certification of ongoing operation and maintenance of treatment BMPs are each required. All storm water management plans are required to obtain certification from a City approved third party reviewer. Resolution No.22 DP-2013-01 September 12,2013 13. EROSION CONTROL PLAN Developer shall provide an approved erosion control plan by a Registered Civil Engineer. This plan should include all erosion control measures used to retain materials on site. Erosion control notes shall be stated on the plans. 14. IMPROVEMENT AGREEMENT The project developer shall enter into a development agreement with the City of Cupertino providing for payment of fees, including but not limited to checking and inspection fees, storm drain fees, park dedication fees and fees for under grounding of utilities. Said agreement shall be executed prior to issuance of construction permits Fees: a. Checking&Inspection Fees: $Per current fee schedule($4,183.00 or 6%) b. Grading Permit: $Per current fee schedule ($2,435.00 or 6%) c. Development Maintenance Deposit: $ 1,000.00 d. Storm Drainage Fee: $TBD e. Power Cost: ** f. Map Checking Fees: $Per current fee schedule(N/A) g. Park Fees: $Per current fee schedule(N/A) h. Street Tree By Developer ** Based on the latest effective PG&E rate schedule approved by th e PUC Bonds: a. Faithful Performance Bond: 100%of Off-site and On-site Improvements b. Labor&Material Bond: 100%of Off-site and On-site Improvement c. On-site Grading Bond: 100%of site improvements. -The fees described above are imposed based upon the current fee schedule adopted by the City Council. However, the fees imposed herein may be modified at the time of recordation of a final map or issuance of a building permit in the event of said change or changes, the fees changed at that time will reflect the then current fee schedule. 15. WORK SCHEDULE Every 6 months, the developer shall submit a work schedule to the City to show the timetable for all grading/erosion control work in conjunction with this project. 16. OPERATIONS&MAINTENANCE AGREEMENT Developer shall enter into an Operations & Maintenance Agreement with the City prior to final occupancy. T'he Agreement shall include the operation and maintenance for non-standard appurtenances in the public road right-of-way that may include, but is not limited to, sidewalk, pavers, and street lights. 17. TRAFFIC SIGNS Traffic control signs shall be placed at locations specified by the City. Resolution No.22 DP-2013-01 September 12,2013 18. FULL TRASH CAPTURE SYSTEM The developer will be responsible for installing a full trash capture system/device to capture trash from the onsite storm drain before the storm water reaches the City owned storm drain system. A full capture system or device is a single device or series of devices that traps all particles retained by a 5 mm mesh screen and has a design treatment capacity of not less than the peak flow rate Q resulting from a one-year, one-hour storm in the sub-drainage area (see the Municipal Regional Permit section C.10 for further information/requirements). 19. TRASH ENCLOSURES AND WASTE/RECYCLING SERVICE The trash enclosure plan must be designed to the satisfaction of the Environmental Programs Manager. Clearance by the Public Works Department is needed prior to obtaining a building permit. Toters instead of front load debris bins are allowed for this project. Tenants shall bring all toters to the curb on the weekly service day and put them in a designated place as approved by the Environmental Programs Manager. Signage may be desired to ensure toters stay in the designated place on service day and do not interfere with parking. Tenants may double-stack toters at the curb without ensuring that the toters face the street and have at least 30 inches between them. 20. REFUSE TRUCK ACCESS Developer shall must obtain clearance from the Environmental Programs Manager in regards to refuse truck access for the proposed development. 21. UNDERGROUND UTILITIES Developer shall comply with the requirements of the Underground Utilities Ordinance No. 331 and other related Ordinances and regulations of the City of Cupertino, and shall coordinate with affected utility providers for installation of underground utility devices. Developer shall submit detailed plans showing utility underground provisions. Said plans shall be subject to prior approval of the affected Utility provider and the City Engineer. All new utility services to the structure shall be placed underground. 22. TRANSFORMERS Electrical transformers, telephone cabinets and similar equipment shall be placed in underground vaults. The developer must receive written approval from both the Public Works Department and the Community Development Department prior to installation of any above ground equipment. Should above ground equipment be permitted by the City, equipment and enclosures shall be screened with fencing and landscaping such that said equipment is not visible from public street areas, as determined by the-Community Development Department. Transformers shall not be located in the front or side building setback area. 23. WATER BACKFLOW PREVENTERS Domestic and Fire Water Backflow preventers and similar above ground equipment shall be placed away from the public right of way and site driveways to a location approved by the Cupertino Planning Department, Santa Clara County Fire Department and the water company. 24. FIRE PROTECTION Fire sprinklers shall be installed in any new construction to the approval of the City. Resolution No.22 DP-2013-01 September 12,2013 25. SANTA CLARA COUNTY FIRE DEPARTMENT A letter of clearance for the project shall be obtained from the Santa Clara County Fire Department prior to issuance of building permits. Clearance should include written approval of the location of any proposed Fire Backflow Preventers, Fire Department Connections and Fire Hydrants (typically Backflow Preventers should be located on private property adjacent to the public right of way, and fire department connections must be located within 100' of a Fire Hydrant). 26. FIRE HYDRANT Fire hydrants shall be located as required by the City and Santa Clara County Fire Department as needed. 27. SAN JOSE WATER COMPANY CLEARANCE Provide San Jose Water Company approval for water connection, service capability and location and layout of water lines and backflow preventers before issuance of a building permit approval. 28. DEDICATION OF WATERLINES Developer shall dedicate to the City all waterlines and appurtenances installed to City Standards and shall reach an agreement with San Jose Water Company for water service to the subject development. 29. DEDICATION OF UNDERGROUND WATER RIGHTS Developer shall "quit claim" to the City all rights to pump, take or otherwise extract water from the underground basin or any underground strata in the Santa Clara Valley. 30. SANITARY DISTRICT A letter of clearance for the project shall be obtained from the Cupertino Sanitary District prior to issuance of building permits. 31. UTILITY EASEMENTS Clearance approvals from the agencies with easements on the property (including PG&E, PacBell, and California Water Company, and/or equivalent agencies) will be required prior to issuance of building perxnits. SECTION V: CONDITIONS ADMINISTERED BY THE SANTA CLARA COUNTY FIRE DEPARTMENT 1. FIRE DEPARTMENT REVIEW Review of this development proposal is limited to acceptability of site access and water supply as they pertain to fire department operations, and shall not be construed as a substitute for formal plan review to determine compliance with adopted model codes. Prior to performing any wark, the applicant shall make application to, and receive from, the Building Department, all applicable construction permits. 2. FIRE SPRINKLERS REQUIRED An automatic sprinkler system shall be provided throughout all new and existing buildings and structures. Exception: Group A, B, E, F, I, L, M, S and U occupancy buildings and structures that do not exceed 1,000 square feet of building area and that are not located in the Wildland-Urban Resolution No.22 DP-2013-01 September 12,2013 Interface Fire Area. NOTE: The owner(s), occupant(s), and any contractor(s) or subcontractor(s) are responsible for consulting with the water purveyor of record in order to determine if any modification or upgrade of the existing water service is required. NOTE: Covered porches, patios, balconies, and attic spaces may require fire sprinlcler coverage. A State of California licensed (C-16) Fire Protection Contractor shall submit plans, calculations, a completed permit application and appropriate fees to this department for review and approval prior to beginning their work. Sections 903.2 as adopted in Section 16-40-210 of the CMC. 3. WATER SUPPLY REQUIREMENTS Potable water supplies shall be protected from contamination caused by fire protection water supplies. It is the responsibility of the applicant and any contractors and subcontractors to contact the water purveyor supplying the site of such project, and to comply with the requirements of that purveyor. Such requirements shall be incorporated into the design of any water-based fire protection system, and/or fire suppression water supply systems or storage containers that may be physically connected in any manner to an appliance capable of causing contamination of the potable water supply of the purveyor of record. Final approval of the system(s) under consideration will not be granted by this office until compliance with the requirements of the water purveyor of record are documented by that purveyor as having been met by the applicant(s). 2010 CFC Sec. 903.3.5 and Health and Safety Code 13114.7. 4. PREMISES IDENT'IFICATION Approved numbers or addresses shall be placed on all new and existing buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Numbers shall contrast with their background. CFC Sec.505. 5. CONSTRUCTION SITE FIRE SAFETY All construction sites must comply with applicable provisions of the CFC Chapter 14 and County Fire Standard Detail and Specification SI-7. SECTION VI: CONDITIONS ADMINISTERED BY THE CUPERTINO SANITARY DISTRICT 1. SANITARY SEWER AVAILABILITY Sanitary sewer service is available on Imperial Avenue. 2. IMPROVEMENT PLANS On-site and off-site improvement plans shall be submitted to the District for review and comments. 3. FEES AND PERMITS Cupertino Sanitary District fees and permits shall be required for the subject application based on the proposed area and use modifications. SECTION VII: CEQA REVIEW This Development Permit is categorically exempt from the California Environmental Quality Act (CEQA) per section 15303 (New Construction) of the CEQA Guidelines because it applies to a mixed residential and commercial building and site improvements not exceeded 10,000 square feet. Resolution No.22 DP-2013-01 September 12,2013 PASSED AND ADOPTED this 12th day of September, 2013 at a Regular Meeting of the Administrative Hearing Meeting of the City of Cupertino, State of California,by the following roll call vote: AYES: HEARING OFFICER: Chao NOES: HEARING OFFICER: none ATTEST: APPROVED: /s/George Schroeder /s/Gar�Chao George Schroeder Gary Chao Associate Planner City Planner ASA-2013-03 CITY OF CUPERTINO 10300 Torre Avenue Cupertino, California 95014 RESOLUTION NO. 23 OF THE ADMINISTRATIVE HEARING MEETING OF THE CITY OF CUPERTINO TO ALLOW AN ARCHITECTURAL AND SITE APPROVAL PERMIT FOR THE CONSTRUCTION OF A NEW TWO-STORY MIXED USE BUILDING WITH ASSOCIATED SITE IMPROVEMENTS AT 10049 IMPERIAL AVENUE SECTION I: PROTECT DESCRIPTION & RECITALS Application No.: ASA-2013-03 Applicant: Terry Brown Property Owner: D.G. and Shirley Long Location: 10049 Imperial Avenue (APN 357-17-013) Subject: Architectural and Site Approval to allow the construction of a new mixed use building ans associated site improvements. WHEREAS, the Administrative Hearing Officer of the City of Cupertino received an application for an Architectural and Site Approval permit as described in Section I. of this Resolution; and WHEREAS, the necessary public notices have been given as required by the Procedural Ordinance of the City of Cupertino, and the Administrative Hearing Officer held a public hearing on September 12, 2013 in regard to the application; and NOW, THEREFORE, BE IT RESOLVED: After careful consideration of the maps, facts, exhibits, testimony and other evidence submitted in this matter, the Administrative Hearing Officer hereby approves Application no. ASA-2013-03 based upon the findings described in Section II of this resolution, the public hearing record, and the minutes of the Administrative Hearing meeting of September 12, 2013, and subject to the conditions specified in Section III of this resolution. SECTION II: FINDINGS: 1. The proposal, at the proposed location, will not be detrimental or injurious to property or improvements in the vicinity, and will not be detrimental to the public health, safety, general welfare, or convenience; The proposed mixed use building will not be detrimental or injurious to property or improvements in the vicinity, and will not be detrimental to the public health, safety,general welfare, or convenience because it is located within a mixed use light industrial, neighborhood commercial, and residential district, which includes a variety of different land uses sfmilar to the one proposed. The City has approved other similar mixed use projects in the neighborhood which is consistent with the City's General Plan Policy 2-24 for Monta Vista. 2. The proposal is consistent with the purposes of Chapter 19.168, Architectural and Site Review, of the Cupertino Municipal Code, the General Plan, any specific plan, zoning ordinances, applicable planned Resolution No.23 ASA-2013-03 September 12,2013 development permit, conditional use perxnits, variances, subdivision maps or other entitlements to use which regulate the subject property including, but not limited to, adherence to the following specific criteria: a) Abrupt changes in building scale have been avoided. A gradual transition related to height and bulk has been achieved between new and existing buildings. The project is compatible with the scale of the surrounding buildings and streetscape in terms of height, bulk, and form. The building design and height are consistent with the Monta Vista Design Guidelines. b) Design harmony between new and existing buildings have been preserved and the materials, textures and colors of new buildings harmonize with adjacent development with design and color schemes, and with the future character of the neighborhood and purposes of the zone in which it is situated. The location, height and materials of walls, fencing, hedges and screen planting harmonize with adjacent development. Unsightly storage areas, utility installations and unsightly elements of parking lots have been concealed. Ground cover or various types of pavements have been used to prevent dust and erosion, and the unnecessary destruction of existing healthy trees have been avoided. Lighting for development is adequate to meet safety requirements as specified by the engineering and building departments, and shielding to adjoining property owners. The project is harmonious with the existing buildings and streetscape in the Monta Vista Planning District. The design is also consistent with the Monta Vista Design Guidelines. No new retaining walls are proposed for the project. All fencing and walls wil be screened by landscaping, and will be minimally visible from public view. All above ground utility installations are required to be screened from public view. The design has incorporated decorative paving material and landscaping, as well as lighting to illuminate pedestrian paths and vehicular routes, which will not glare onto adjoining properties. The City's consulting arborist has confirmed that the existing trees proposed for removal are not suitable for preservation and will be replaced by appropriate replacement trees. The remaining Coast Live Oak tree suitable for preservation is requfred to be transplanted elsewhere on the project site. c) The number, location, color, size, height, lighting and landscaping of outdoor advertising signs and structures have been designed to minimize traffic hazard, positively affect the general appearance of the neighborhood and harmonize with adjacent development. No exterior signage is approved as part of this application. Project signage, if any, is required to adhere to the City's Sign Ordinance. Parking lot directional signage will be reviewed and approved by City staff prior to building permit issuance. d) This new development, not abutting an existing residential development, has been designed to protect residents from noise, traffic, light and visually intrusive effects by use of buffering, setbacks, landscaping, walls and other appropriate design measures. The project is designed to protect residents from noise, traffic, light, and visually intrusive effects by use of buffering, setbacks, and landscaping. The project has been designed to mitigate any potentially intrusive effects to the surrounding area. SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY DEVELOPMENT DEPT. Planning Division: 1. APPROVED EXHIBITS Approval is based on plan sets received on August 23, 2013, titled "A Mixed Use Project with all new Construction for 10049 Imperial Ave., Cupertino, CA, 95014", consisting of five sheets labeled "Sheet Resolution No.23 ASA-2013-03 September 12,2013 No. 1 to Sheet No. 5 " and titled "Imperial Ave. Street Elevation,"consisting of twelve sheets labeled "L1.0 to L.4.0 and Sheet 1 to Sheet 6"drawn by Ray Rooker Architect, Reed Associates Landscape Architecture, and Nordic Engineering Inc. except as may be amended by conditions in this resolution. 2. ACCURACY OF PROJECT PLANS The applicant/property owner is responsible to verify all pertinent property data including but not limited to property boundary locations, building setbacks, property size, building square footage, any relevant easements and/or construction records. Any misrepresentation of any property data may invalidate this approval and may require additional review. 3. ANNOTATION OF THE CONDITIONS OF APPROVAL The conditions of approval set forth shall be incorporated into and annotated on the first page of the building plans. 4. CONCURRENT APPROVAL CONDITIONS T'he conditions of approval contained in file nos. DP-2013-01 and TR-2013-12 shall be applicable to this approval. 5. FINAL BUILDING DESIGN The final building design and exterior treatment plans shall be reviewed and approved by the Director of Community Development prior to issuance of building permits. The Director of Community Development may approve additional designs or make minor variations as deemed appropriate. The final building exterior plan shall closely resemble the details shown on the original approved plans. Any exterior changes determined to be substantial by the Director of Community Development shall require a modification approval. 6. DRIVEWAY AND PARKING PAD MATERIAL The site driveways, drive aisles, and parking pads shall consist of pavers or other similar decorative semi-pervious material to the maximum extent possible as determined by the Director of Community Development in consulation with the Director of Public Works. 7. PARKWAY AND SIDEWALK WIDTH The construction plans shall include a 6 foot wide parkway along the curb and a 5 foot wide public sidewalk along the project frontage, beginning south of the southern driveway on 21666-21686 Stevens Creek Boulevard (APN 357-17-012). T'he final details shall be reviewed by the Director of Community Development in conjunction with the Director of Public Works prior to issuance of building,�ermits. 8. FRONTAGE DETAILS The final street frontage details, including, but not limited to onstreet parking size and details, sidewalk paving material and widths, street furniture, landscaping and tree selection shall be subject to review and approval by the Director of Community Development in consultation with the Director of Public Works�rior to building permit issuance. Paver blocks or other similar material shall be placed over the parkway to avoid damage to the parkway landscaping. 9. CONSULTATION WITH OTHER DEPARTMENTS The applicant is responsible to consult with other departments and/or agencies with regard to the proposed project for additional conditions and requirements. Any misrepresentation of any submitted data may invalidate an approval by the Community Development Department. Resolution No.23 ASA-2013-03 September 12,2013 10. INDEMNIFICATION To the extent permitted by law, the Applicant shall indemnify and hold harmless the City, its City Council, its officers, employees and agents (the "indemnified parties") from and against any claim, action, or proceeding brought by a third party against the indemnified parties and the applicant to attack, set aside, or void this ordinance or any permit or approval authorized hereby for the project, including (without limitation) reimbursing the City its actual attorneys' fees and costs incurred in defense of the litigation. The City may, in its sole discretion, elect to defend any such action with attorneys of its choice. 11. NOTICE OF FEES, DEDICATIONS, RESERVATIONS OR OTHER EXACTIONS The Conditions of Project Approval set forth herein may include certain fees, dedication requirements, reservation requirements, and other exactions. Pursuant to Government Code Section 66020(d) (1), these Conditions constitute written notice of a statement of the amount of such fees, and a description of the dedications, reservations, and other exactions. You are hereby further notified that the 90-day approval period in which you may protest these fees, dedications, reservations, and other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest within this 90- day period complying with all of the requirements of Section 66020, you will be legally barred from later challenging such exactions. SECTION IV: CEQA REVIEW This Architectural and Site Approval permit is categorically exempt from the Califomia Environmental Quality Act (CEQA) per section 15303 (New Construction) of the CEQA Guidelines because it applies to a mixed residential and commercial building and site improvements not exceeded 10,000 square feet. PASSED AND ADOPTED this 12th day of September, 2013 at a Regular Meeting of the Administrative Hearing Meeting of the City of Cupertino, State of California,by the following roll call vote: AYES: HEARING OFFICER: Chao NOES: HEARING OFFICER:none ATTEST: APPROVED: /s/Geor�e Schroeder /s/Gary Chao George Schroeder Gary Chao Associate Planner City Planner TR-2013-12 CITY OF CUPERTINO 10300 Torre Avenue Cupertino, California 95014 RESOLUTION NO. 24 OF THE ADMINISTRATIVE HEARING MEETING OF THE CITY OF CUPERTINO TO ALLOW A TREE REMOVAL PERMIT FOR THE TRANSPLANTATION OF AN 18.2- INCH COAST LIVE OAK TREE AND THE REMOVAL AND REPLACEMENT OF A 24- INCH DIAMETER PITTOSPORUM TREE AND TWO MULTI-TRUNK CALIFORNIA PEPPER TREES ON THE SITE OF A NEW MIXED USE BUILDING AT 10049 IMPERIAL AVENUE SECTION I: PROTECT DESCRIPTION &RECITALS Application No.: TR-2013-12 Applicant: Terry Brown Property Owner: D.G. and Shirley Long Location: 10049 Imperial Avenue (APN 357-17-013) Subject: Tree Removal Permit to allow the transplantation of one tree and the removal and replacement of three trees. WHEREAS, the Administrative Hearing Officer of the City of Cupertino received an application for a Tree Removal Permit as described in Section I. of this Resolution; and WHEREAS, the necessary public notices have been given as required by the Procedural Ordinance of the City of Cupertino, and the Administrative Hearing Officer held a public hearing on September 12, 2013 in regard to the application; and NOW, THEREFORE,BE IT RESOLVED: After careful consideration of the maps, facts, exhibits, testimony and other evidence submitted in this matter, the Administrative Hearing Officer hereby approves Application no. TR-2013-12 based upon the findings described in Section II of this resolution, the public hearing record, and the minutes of the Administrative Hearing meeting of September 12, 2013, and subject to the conditions specified in Section III of this resolution. SECTION II: FINDINGS: 1. That the trees are irreversibly diseased, are in danger of falling, can cause potential damage to existing or proposed essential structures, or interferes with private on-site utility services and cannot be controlled or remedied through reasonable relocation or modification of the structure or utility services; The City's consulting arborist has determined that the trees proposed for removal are all in conflict wfth the proposed new building and site improvements, and, given their condition, are not suitable for preservation or relocation. Resolution No.24 TR-2013-12 September 12,2013 2. That the location of the trees restricts the economic enjoyment of the property by severely limiting the use of property in a manner not typically experienced by owners of similarly zoned and situated property, and the applicant has demonstrated to the satisfaction of the approval authority that there are no reasonable alternatives to preserve the tree(s). The City's consulting arborist has determined that the trees proposed for removal are all in conflict with the proposed new building and site improvements, and, gfven their condition, are not suftable for preservation or relocation. SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY DEVELOPMENT DEPT. Planning Division: 1. APPROVED EXHIBITS Approval is based on plan sets received on August 23, 2013, titled "A Mixed Use Project with all new Construction for 10049 Imperial Ave., Cupertino, CA, 95014", consisting of five sheets labeled "Sheet No. 1 to Sheet No. 5 " and titled "Imperial Ave. Street Elevation,"consisting of twelve sheets labeled "L1.0 to L.4.0 and Sheet 1 to Sheet 6"drawn by Ray Rooker Architect, Reed Associates Landscape Architecture, and Nordic Engineering Inc.; The consulting arborist report entitled, "An Evaluation of an Oak tree at 10049 Imperial Avenue, Cupertino, California," and, "A Review of the Existing Trees at 10049 Imperial Avenue, Cupertino, California," prepared by Michael Bench, Registered Consulting Arborist #WE-1897 dated November 26, 2012 and July 31, 2013, respectively; except as may be amended by conditions in this resolution. 2. ACCURACY OF PROJECT PLANS The applicant/property owner is responsible to verify all pertinent property data including but not limited to property boundary locations, building setbacks, property size, building square footage, any relevant easements and/or construction records. Any misrepresentation of any property data may invalidate this approval and may require additional review. 3. ANNOTATION OF THE CONDITIONS OF APPROVAL The conditions of approval set forth shall be incorporated into and annotated on the first page of the building plans. 4. CONCURRENT APPROVAL CONDITIONS The conditions of approval contained in file nos. DP-2013-01 and ASA-2013-03 shall be applicable to this approval. 5. TREE APPPROVED FOR TRANSPLANTING The existing 18.2-inch diameter Coast Live Oak tree is approved to be transplanted elsewhere on the site as determined by the Director of Community Development in consultation with the City Arborist. The applicant shall obtain the services of the City Arborist to recommend measures to ensure the survival to the maximum extent possible. These recommendations shall be provided prior to issuance of building/demolition permits. A report ascertaining the health of the trees mentioned above after relocation shall be provided prior to final occupancX. In the event that the tree transplantation is not deemed feasible by the Director of Community Development, tree replacements shall be provided per the Protected Tree Ordinance. Resolution No.24 TR-2013-12 September 12,2013 6. APPROVED TREE REMOVALS See the table below for the approved list of three tree removals onsite: Approved ` tjree fteason for removal General location ' Approval removal findin s section Tree 1, 24" Conflict with proposed North side property 14.18.180 (A)(1), Pittos orum tree essential structures line (2) Tree 3, Multi-trunk Planter along rear 14.18.180 (A)(1) California Pepper property line tree Tree 4, Multi-trunk Irreversible disease California Pepper tree 7. TREE REPLACEMENTS AND FINAL PLANTING PLAN The applicant shall plant replacement trees in accordance with the replacement requirements of the Protected Tree Ordinance. The trees shall be planted�rior to final occu�anc�of site�ermits. The final planting plan shall be reviewed and approved by the Director of Community Development with consultation by the City Arborist �rior to issuance of building permits. The Director of Community Development shall have the discretion to require additional tree replacements as deemed necessary. The City Arborist shall confirm that the replacement trees were planted properly and according to plan prior to final occupancy. 8. TREE REPLACEMENT BOND The applicant shall provide a tree replacement bond in an amount determined by the City Arborist prior to removals and issuance of demolition and grading permits. The bond shall be returned after the required tree replacements have been planted and verified by the Cit y Arborist. 9. CONSULTATTON WITH OTHER DEPARTMENTS The applicant is responsible to consult with other departments and/or agencies with regard to the proposed project for additional conditions and requirements. Any misrepresentation of any submitted data may invalidate an approval by the Community Development Department. 10. INDEMNIFICATTON To the extent perxnitted by law, the Applicant shall indemnify and hold harmless the City, its City Council, its officers, employees and agents (the "indemnified parties") from and against any claim, action, or proceeding brought by a third party against the indemnified parties and the applicant to attack, set aside, or void this ordinance or any permit or approval authorized hereby for the project, including (without limitation) reimbursing the City its actual attorneys' fees and costs incurred in defense of the litigation. The City may, in its sole discretion, elect to defend any such action with attorneys of its choice. 11. NOTICE OF FEES DEDICATIONS, RESERVATIONS OR OTHER EXACTIONS The Conditions of Project Approval set forth herein may include certain fees, dedication requirements, reservation requirements, and other exactions. Pursuant to Government Code Section 66020(d) (1), these Conditions constitute written notice of a statement of the amount of such fees, Resolution No.24 TR-2013-12 September 12,2013 and a description of the dedications, reservations, and other exactions. You are hereby further notified that the 90-day approval period in which you may protest these fees, dedications, reservations, and other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest within this 90-day period complying with all of the requirements of Section 66020, you will be legally barred from later challenging such exactions. SECTION IV: CEQA REVIEW This Tree Removal Permit is categorically exempt from the California Environmental Quality Act (CEQA) per section 15303 (New Construction) of the CEQA Guidelines because it applies to a mixed residential and commercial building and site improvements not exceeding 10,000 square feet. PASSED AND ADOPTED this 12th day of September, 2013 at a Regular Meeting of the Administrative Hearing Meeting of the City of Cupertino, State of California,by the following roll call vote: AYES: HEARING OFFICER: Chao NOES: HEARING OFFICER: none ATTEST: APPROVED: /s/Geor�e Schroeder /s/Gary Chao George Schroeder Gary Chao Associate Planner City Planner ASA-2013-04 CITY OF CUPERTINO 10300 Torre Avenue Cupertino, California 95014 RESOLUTION NO. 25 OF THE ADMINISTRATIVE HEARING MEETING OF THE CITY OF CUPERTINO TO ALLOW AN ARCHITECTURAL AND SITE APPROVAL PERMIT FOR MODIFICATIONS TO THE PARKING LOT LAYOUT TO FACILITATE RECIPROCAL INGRESS AND EGRESS AT THE STANLEY SQUARE CENTER IN THE MONTA VISTA SPECIAL PLANNING DISTRICT AT 21666-21686 STEVENS CREEK BOULEVARD SECTION I: PROJECT DESCRIPTION &RECITALS Application No.: ASA-2013-04 Applicant: Terry Brown Property Owner: Barbara Kalman, et al. Location: 21666-21686 Stevens Creek Boulevard (APN 357-17-012) Subject: Architectural and Site Approval to allow modifications to the parking lot layout and to facilitate a new driveway connection. WHEREAS, the Administrative Hearing Officer of the City of Cupertino received an application for an Architectural and Site Approval permit as described in Section I. of this Resolution; and WHEREAS, the necessary public notices have been given as required by the Procedural Ordinance of the City of Cupertino, and the Administrative Hearing Officer held a public hearing on September 12, 2013 in regard to the application; and NOW, THEREFORE, BE IT RESOLVED: After careful consideration of the maps, facts, exhibits, testimony and other evidence submitted in this matter, the Administrative Hearing Officer hereby approves Application no. ASA-2013-04 based upon the findings described in Section II of this resolution, the public hearing record, and the minutes of the Administrative Hearing meeting of September 12, 2013, and subject to the conditions specified in Section III of this resolution. SECTION II: FINDINGS: l. The proposal, at the proposed location, will not be detrimental or injurious to property or improvements in the vicinity, and will not be detrimental to the public health, safety, general welfare, or convenience; The proposed parking lot modifications will not be detrimental or injurious to property or improvements in the vicinity, and will not be detrimental to the public health, safety, general welfare, or convenience because it is compatible with the City's Parking Ordinance and will enhance the existing internal and external circulation. The new shared access driveway is consistent with the General Plan Policy 2-24 and 4-9. Resolution No.25 ASA-2013-04 September 12,2013 2. The proposal is consistent with the purposes of Chapter 19.168, Architectural and Site Review, of the Cupertino Municipal Code, the General Plan, any specific plan, zoning ordinances, applicable planned development permit, conditional use permits, variances, subdivision maps or other entitlements to use which regulate the subject property including, but not limited to, adherence to the following specific criteria: a) Abrupt changes in building scale have been avoided. A gradual transition related to height and bulk has been achieved between new and existing buildings. The project proposes no changes to the existing building onsite. b) Design harmony between new and existing buildings have been preserved and the materials, textures and colors of new buildings harmonize with adjacent development with design and color schemes, and with the future character of the neighborhood and purposes of the zone in which it is situated. The location, height and materials of walls, fencing, hedges and screen planting harmonize with adjacent development. Unsightly storage areas, utility installations and unsightly elements of parking lots have been concealed. Ground cover or various types of pavements have been used to prevent dust and erosion, and the unnecessary destruction of existing healthy trees have been avoided. Lighting for development is adequate to meet safety requirements as specified by the engineering and building departments, and shielding to adjoining property owners. The project proposes no changes to the existing building onsite. The design and features of the modified parking lot are consistent with the Monta Vista Design Guidelines and the City's Parking Ordinance. No new retaining walls are proposed for the project. All above ground utility installations are required to be screened from public view. The design has fncorporated decoratfve paving material and landscaping, as well as lighting to illuminate pedestrian paths and vehicular routes, which will not glare onto adjoining properties. The City's consulting arborist has confirmed that the existing trees proposed for removal are not suitable for preservation and will be replaced by appropriate replacement trees. c) T'he number, location, color, size, height, lighting and landscaping of outdoor advertising signs and structures have been designed to minimize traffic hazard, positively affect the general appearance of the neighborhood and harmonize with adjacent development. No exterior signage is approved as part of this application. Project signage, if any, is required to adhere to the City's Sign Ordinance. Parking lot directional signage will be reviewed and approved by City staff prior to building permit issuance. d) This new development, not abutting an existing residential development, has been designed to protect residents from noise, traffic, light and visually intrusive effects by use of buffering, setbacks, landscaping, walls and other appropriate design measures. The project is designed to protect neighboring residents from noise, traffic, light, and visually intrusive effects by use of landscaping and lighting in accordance with the City's Parking Ordinance. The project has been designed to mitigate any potentially intrusive effects to the surrounding area. Resolution No.25 ASA-2013-04 September 12,2013 SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY DEVELOPMENT DEPT. Planning Division: 1. APPROVED EXHIBITS Approval is based on plan sets received on August 23, 2013, titled "A Mixed Use Project with all new Construction for 10049 Imperial Ave., Cupertino, CA, 95014", consisting of five sheets labeled "Sheet No. 1 to Sheet No. 5 " and titled "Imperial Ave. Street Elevation,"consisting of twelve sheets labeled "L1.0 to L.4.0 and Sheet 1 to Sheet 6"drawn by Ray Rooker Architect, Reed Associates Landscape Architecture, and Nordic Engineering Inc. except as may be amended by conditions in this resolution. 2. ACCURACY OF PROTECT PLANS The applicant/property owner is responsible to verify all pertinent property data including but not limited to property boundary locations, building setbacks, property size, building square footage, any relevant easements and/or construction records. Any misrepresentation of any property data may invalidate this approval and may require additional review. 3. ANNOTATION OF THE CONDITIONS OF APPROVAL The conditions of approval set forth shall be incorporated into and annotated on the first page of the building plans. 4. CONCURRENT APPROVAL CONDITIONS The conditions of approval contained in file no. TR-2013-32 shall be applicable to this approval. 5. PREVIOUS CONDITIONS OF APPROVAL The following previous conditions of approval for the project site shall remain in effect: Z-1980-40,U-1996-13,ASA-2002-02,EXC-2003-05, S-2011-04 • All conditions 6. FINAL LIGHTING PLAN All new lighting must conform to the standards in the Parking Ordinance (Chapter 19.124) and General Commercial Ordinance (Chapter 19.60), and the final lighting plan (including a detailed photometric plan) shall be reviewed and approved by the Community Development Director nrior to building permit issuance. Prior to final occu�ancy, a licensed lighting consultant shall confirm that the lighting is in compliance with the City's standards. The illumination in the parking lot shall meet the minimum standards as specified in the Parking and General Commercial Ordinances. 7. FINAL BUILDING DESIGN The final building design and exterior treatment plans shall be reviewed and approved by the Director of Community Development prior to issuance of building permits. The Director of Community Development may approve additional designs or make minor variations as deemed appropriate. The final building exterior plan shall closely resemble the details shown on the original approved plans. Any exterior changes determined to be substantial by the Director of Community Development shall require a modification approval. Resolution No.25 ASA-2013-04 September 12,2013 8. PARKWAY AND SIDEWALK WIDTH The construction plans shall include a 6 foot wide parkway along the curb and a 5 foot wide public sidewalk along the project frontage, beginning south of the southern driveway. The final details shall be reviewed by the Director of Community Development in consultation with the Director of Public Works�rior to buildin�vermit issuance. 9. FRONTAGE DETAILS The final street frontage details, including, but not limited to onstreet parking size and design, sidewalk paving material and widths, street furniture, landscaping and tree selection shall be subject to review and approval by the Director of Community Development in consultation with the Director of Public Works�rior to building permit issuance. Paver blocks or other similar material shall be placed over the parkway to avoid damage to the parkway landscaping. 10. INGRESS/EGRESS EASEMENT The property owner shall record an appropriate deed restriction for necessary vehicular and pedestrian reciprocal ingress and egress, subject to approval of the City Attorney, to and from 10049 Imperial Avenue (APN 357-17-013). The easement shall be recorded �rior to final occupancy of site permits. A previously recorded covenant (Santa Clara County Recorder's Document no. 16876454) requires the participation of the reciprocal easement 11. PARKING EASEMENT The property owner shall record an appropriate deed restriction and covenant running with the land, subject to approval of the City Attorney, entering into a parking access agreement for the northern portion of the property at 10049 Imperial Avenue (APN 357-17-013). The easement shall be recorded �rior to final occu�anc�of site�ermits. 12. SHARED ACCESS DRIVEWAY The proposed shared access driveway between the project site and 10049 Imperial Avenue (APN 357-17-013) shall be fully installed and constructed to the satisfaction of the Public Works Director and Community Development Director �rior to the issuance of final occu�anc� of site permits. 13. PARKING LOT MAINTENANCE AGREEMENT/MANAGEMENT PLAN Prior to final occu�ancy, the applicant shall record a parking lot maintenance agreement and management plan, subject to the approval of the City Attorney. This shall include, but not be limited to, the parking easement area, assignxnent of parking stalls, maintenance of landscaping, stall striping, surfacing, and stalls that straddle the property at 10049 Imperial Avenue (APN 357-17-013). 14. CONSULTATION WITH OTHER DEPARTMENTS The applicant is responsible to consult with other departments and/or agencies with regard to the proposed project for additional conditions and requirements. Any misrepresentation of any submitted data may invalidate an approval by the Community Development Department. 15. INDEMNIFICAT'ION To the extent permitted by law, the Applicant shall indemnify and hold harmless the City, its City Council, its officers, employees and agents (the "indemnified parties") from and against any claim, Resolution No.25 ASA-2013-04 September 12,2013 action, or proceeding brought by a third party against the indemnified parties and the applicant to attack, set aside, or void this ordinance or any permit or approval authorized hereby for the project, including (without limitation) reimbursing the City its actual attorneys' fees and costs incurred in defense of the litigation. The City may, in its sole discretion, elect to defend any such action with attorneys of its choice. 16. NOTICE OF FEES DEDICATIONS. RESERVATIONS OR OTHER EXACTIONS The Conditions of Project Approval set forth herein may include certain fees, dedication requirements, reservation requirements, and other exactions. Pursuant to Government Code Section 66020(d) (1), these Conditions constitute written notice of a statement of the amount of such fees, and a description of the dedications, reservations, and other exactions. You are hereby further notified that the 90-day approval period in which you may protest these fees, dedications, reservations, and other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest within this 90-day period complying with all of the requirements of Section 66020, you will be legally barred from later challenging such exactions. SECTION IV: CEQA REVIEW This Architectural and Site Approval permit is categorically exempt from the California Environmental Quality Act (CEQA) per section 15301 (Existing Facilities) of the CEQA Guidelines since it involves minor parking lot alterations to an existing developed site. PASSED AND ADOPTED this 12th day of September, 2013 at a Regular Meeting of the Administrative Hearing Meeting of the City of Cupertino, State of California,by the following roll call vote: AYES: HEARING OFFICER: Chao NOES: HEARING OFFICER:none ATTEST: APPROVED: /s/George Schroeder /s/Gary Chao George Schroeder Gary Chao Associate Planner City Planner TR-2013-32 CITY OF CUPERTINO 10300 Torre Avenue Cupertino, California 95014 RESOLUTION NO. 26 OF THE ADMINISTRATIVE HEARING MEETING OF THE CITY OF CUPERT'INO TO ALLOW A TREE REMOVAL PERMIT FOR THE REMOVAL AND REPLACEMENT OF FOUR FLOWERING PEAR TREES AS PART OF MODIFICATIONS TO THE PARKING LOT LAYOUT 21666-21686 STEVENS CREEK BOULEVARD SECTION I: PROJECT DESCRIPTION&RECITALS Application No.: TR-2013-32 Applicant: Terry Brown Property Owner: Barbara Kalman, et al. Location: 21666-21686 Stevens Creek Boulevard (APN 357-17-012) Subject: Tree Removal Permit to allow the removal and replacement of four trees. WHEREAS, the Administrative Hearing Officer of the City of Cupertino received an application for a Tree Removal Permit as described in Section I. of this Resolution; and WHEREAS, the necessary public notices have been given as required by the Procedural Ordinance of the City of Cupertino, and the Administrative Hearing Officer held a public hearing on September 12, 2013 in regard to the application; and NOW, THEREFORE, BE IT RESOLVED: After careful consideration of the maps, facts, exhibits, testimony and other evidence submitted in this matter, the Administrative Hearing Officer hereby approves Application no. TR-2013-32 based upon the findings described in Section II of this resolution, the public hearing record, and the minutes of the Administrative Hearing meeting of September 12, 2013, and subject to the conditions specified in Section III of this resolution. SECTION II: FINDINGS: 1. That the trees are irreversibly diseased, are in danger of falling, can cause potential damage to existing or proposed essential structures, or interferes with private on-site utility services and cannot be controlled or remedied through reasonable relocation or modification of the structure or utility services; The City's consulting arborist has determined that the trees proposed for removal are all in conflict with the proposed new building and site improvements, and, given their condition, are not suitable for preservation or relocation. 2. That the location of the trees restricts the economic enjoyment of the property by severely limiting the use of property in a manner not typically experienced by owners of similarly zoned and situated Resolution No.26 TR-2013-32 September 12,2013 property, and the applicant has demonstrated to the satisfaction of the approval authority that there are no reasonable alternatives to preserve the tree(s). The City's consulting arborist has determined that the trees proposed for removal are all in conflict with the proposed new building and site improvements, and, given their condition, are not suitable for preservation or relocation. SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY DEVELOPMENT DEPT. Planning Division: 1. APPROVED EXHIBITS Approval is based on plan sets received on August 23, 2013, titled "A Mixed Use Project with all new Construction for 10049 Imperial Ave., Cupertino, CA, 95014", consisting of five sheets labeled "Sheet No. 1 to Sheet No. 5 " and titled "Imperial Ave. Street Elevation,"consisting of twelve sheets labeled "L1.0 to L.4.0 and Sheet 1 to Sheet 6"drawn by Ray Rooker Architect, Reed Associates Landscape Architecture, and Nordic Engineering Inc. and, "A Review of the Existing Trees at 10049 Imperial Avenue, Cupertino, California," prepared by Michael Bench, Registered Consulting Arborist # WE-1897 dated November 26, 2012 and July 31, 2013, respectively; except as may be amended by conditions in this resolution. 2. ACCURACY OF PROTECT PLANS The applicant/property owner is responsible to verify all pertinent property data including but not limited to property boundary locations, building setbacks, property size, building square footage, any relevant easements and/or construction records. Any misrepresentation of any property data may invalidate this approval and may require additional review. 3. ANNOTATION OF THE CONDITIONS OF APPROVAL The conditions of approval set forth shall be incorporated into and annotated on the first page of the building plans. 4. CONCURRENT APPROVAL CONDITIONS T'he conditions of approval contained in file no. ASA-2013-04 shall be applicable to this approval. 5. APPROVED TREE REMOVALS See the table below for the a roved list of three tree removals onsite: Approved tree: Reason for removal ' General location Appxoval removaX findin s section Tree 5, 6" Conflict with proposed South side property 14.18.180(A)(1) Flowerin Pear essential structures line Tree 6, 6" Irreversible disease Planter along rear Flowerin Pear property line Tree 7, 6" Flowerin Pear Tree 8, 6" Flowerin Pear Resolution No.26 TR-2013-32 September 12,2013 6. TREE REPLACEMENTS AND FINAL PLANTING PLAN The applicant shall plant replacement trees in accordance with the replacement requirements of the Protected Tree Ordinance. The trees shall be planted prior to final occu�anc�of site�ermits. The final planting plan shall be reviewed and approved by the Director of Community Development with consultation by the City Arborist �rior to issuance of buildin� permits. The Director of Community Development shall have the discretion to require additional tree replacements as deemed necessary. The City Arborist shall confirm that the replacement trees were planted properly and according to plan prior to final occupancy. 7. TREE REPLACEMENT BOND The applicant shall provide a tree replacement bond in an amount determined by the City Arborist prior to removals and issuance of demolition and grading permits. The bond shall be returned after the required tree replacements have been planted and verified by the City Arborist. 8. CONSULTATION WITH OTHER DEPARTMENTS The applicant is responsible to consult with other departments and/or agencies with regard to the proposed project for additional conditions and requirements. Any misrepresentation of any submitted data may invalidate an approval by the Community Development Department. 9. INDEMNIFICATION To the extent permitted by law, the Applicant shall indemnify and hold harmless the City, its City Council, its officers, employees and agents (the "indemnified parties") from and against any claim, action, or proceeding brought by a third party against the indemnified parties and the applicant to attack, set aside, or void this ordinance or any permit or approval authorized hereby for the project, including (without limitation) reimbursing the City its actual attorneys' fees and costs incurred in defense of the litigation. The City may, in its sole discretion, elect to defend any such action with attorneys of its choice. 10. NOTICE OF FEES, DEDICATIONS, RESERVATIONS OR OTHER EXACTIONS The Conditions of Project Approval set forth herein may include certain fees, dedication requirements, reservation requirements, and other exactio ns. Pursuant to Government Code Section 66020(d) (1), these Conditions constitute written notice of a statement of the amount of such fees, and a description of the dedications, reservations, and other exactions. You are hereby further notified that the 90-day approval period in which you may protest these fees, dedications, reservations, and other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest within this 90-day period complying with all of the requirements of Section 66020,you will be legally barred from later challenging such exactions. SECTION IV: CEQA REVIEW This Tree Removal Permit is categorically exempt from the California Environmental Quality Act (CEQA) per section 15301 (Existing Facilities) of the CEQA Guidelines since it involves minor parking lot alterations to an existing developed site. Resolution No.26 TR-2013-32 September 12,2013 PASSED AND ADOPTED this 12th day of September, 2013 at a Regular Meeting of the Administrative Hearing Meeting of the City of Cupertino, State of California,by the following roll call vote: AYES: HEARING OFFICER: Chao NOES: HEARING OFFICER:none ATTEST: APPROVED: /s/George Schroeder /s/Gary Chao George Schroeder Gary Chao Associate Planner City Planner Attachment 2 Oak Tree at 6 _ N .�. _L_� j r��I� -�.j.i� 10049 Imperial Avenue t�` � ` '�" ` �� � _�o_____�..� . Cupertino, California j`�'��������� er _ �_� ___ ...�..,� .:.,,��..��' .,�u:.�,,,�.�w„�..y AN EVALUATION OF AN OAK TREE AT ...-� 10049 IMPERIAL AVENUE - -�-°� - CUPERTINO, CALIFORNIA '�� -�� ����� - � Assignment ���L' '� ���'`�� � I was asked by Piu Ghosh, Planner, City of Cupertino, to evaluate an oak tree at 10049 Imperial Avenue, Cupertino, California. The plan provided for this evaluation is the Topographic Survey, prepared by Nordic Engineering, Inc., Sheet 1, dated July 2012. Observations I inspected the subject oak tree on November 26, 2012. The subject tree is a coast live oak(Quercus agrifolia). The trunk of this tree measures 18.2 inches DBH (Diameter at Breast Height= 54 inches above grade). The canopy is approximately 30 feet in height, and the canopy spread is approximately 25 feet in diameter. This tree is located in the back yard � ;� adj acent to the garage at the location ��F � �.� � � �� °�� ' noted. It appears that the foundation of � .�w'��`��� � #° - this garage is a concrete slab on grade. :,�.,�' +^ �,� +�.""`� `� � ' „�p,�'m�, ��r ' � " �e * u"�' e ' � �� ,���.T. :_, '-�'�" - , The canopy is dense, a primary indicator �� � a9 of good health. �� ��,: `� � +�w . ' The annual tip growth is 6-8 inches, ��s .� � � . �4�'��� �N� *°�,��� � -�;# which is good for this species. . .� . , r� �, �� �.� "a. � �, .� � „a��` � � � � r ��-- � � �� The leaf color is deep dark green, � �,. � q �� _4���• �{.,� � ��� � `��' ',� q � characteristic of a healthy specimen of �..��r� � „.;,, � �. ...��- _. � � c � �t, e _...�,,..»..� ..��.�� � � . , � .� �. this species. �,�' �-;"' � ,. ..� ,,F�' ,� � �� ,��� t M�� ��� � ,a� .: ` � � �, � ���.. --�r .; °� : ������� ���� There is minor branch tip die back, caused �� %r��� Q� � �'� ` ��3 A ��� ��;�� by oak twig blight (Cryptocline �� � � ,.; . � � k���n ��� � ` cinerescens) which is rarely a serious �,� 1 � �,, f � � �� � ; � , >� � '� � � #' �� �� ��" � � '��� health risk to coast live oak trees. The ; wx �a a'... ..¢c *s`c�� 1. �',� � . f .s. Y 4 �� � . . - �k�� �`�'�"� ° �" infection to this tree at this time is minor. ,,� q:� �� ��, �F`y� �:T. Mr`^iYR .�°r This tree has been recently pruned on the south side (facing the garage). This has created visible gaps seen in this photo in the canopy above the garage. Some of the pruning cuts were very poorly done, leaving stubbed branches, which is often called "topping". This type of pruning (topping) is a destructive form of pruning, and is not recommended. This topping has affected approximately 1/ of the overall canopy. Prepared by Michael L. Bench, Consulting Arborist November 26, 2012 Oak Tree at 10049 Imperial Avenue Cupertino, California Although the lower trunk of this tree leans slightly(approximately 5 degrees)to the north, this is not a significant problem concerning its stability. There are two eye-bolts in the trunk on the west side, which is also not a concern concerning health or stability. There are no visible significant weaknesses in the branching structure, except for the "topped"portion of the canopy on the south side. The plan proposes to construct a driveway across the area where this oak tree exists. Conclusions This coast live oak overall is healthy except for a minor infection of oak twig blight, which can be controlled by spraying or eradicative pruning (removing the branch tips about 1 foot behind the dead twigs). The structural integrity is good, despite the fact that a percentage of the canopy has been topped. This can be corrected by proper pruning. There is no compelling reason to remove this tree for health or structural reasons. It would be possible to transplant this tree with a good expectation of success, provided it would be done by an experienced tree mover. Experienced tree movers include: Pacific Tree Moving(408) 231-7017 or(831) 475-6190 Environmental Design (831) 915-0358 John Arnaz Tree Movers (408)266-1717 Valley Crest Tree Company(818) 367-5803 Respectfully submitted, :`�__ �,,�___ Michael L. Bench, Consulting Arborist International Society of Arboriculture Certification#WE 1897 American Society of Consulting Arborists Member Prepared by Michael L. Bench, Consulting Arborist November 26, 2012 �„ --�� 1� — �c i:/� �,��;r��•���,�,L '�"�''' �j�"�� A Review of the Existing Trees at s.._.�..�:� 10049 Imperial Avenue ��'''�'�`�'��a'�'� �'�i�����er Cu ertino, California .� .,.,-.��., ,_ t������.� p ._��,�__._�. ._.�..«.�,.�..,,. �� ,r.. ,�, .,.. , , . . „ � - ....�._.,....._ ._..�_�.�.�.,..� A REVIEW OF THE EXISTING TREES AT , 10049 IMPERIAL AVENUE 7c�C� e ���vvoc�t CUPERTINO CALIFORNIA � � Assignment I was asked by George Schroeder, Planner, City of Cupertino, to evaluate the trees at 10049 Imperial Avenue, Cupertino, California. The plans provided for this evaluation were prepared by Ray Hooker, Architect. I have marked up the Site Plan to show the locations of the trees reviewed for this report. Observations I inspected the trees on July 31, 2013. "''�'�����y'y,����'°° � Tree # l (in this photo to the left) is a ��������' Victorian Box tree (PittospoYUm undiilatum). ,� � � �i,�/�„�, „ . � i i r i. i r i i �; �;/���x�����/������✓hi�%yi�/�/N�'�ji10 iir ti r -r � ��� � �� ������ ;,;;,% � %��.; �- ��� � It has four trunks, measured to be 10, 9, 8, 8 inches DBH (Diameter at Breast Height= 54 �a �-��:���� "" inches above grade). The canopy is "�' �. "� �swm��'".. ��`��� � �����'��" �� �, approximately 30 feet in height, and the � °�� �� -� � "� �� ,.- canopy spread is approximately 30 feet in � � ��� ���� � � � ���� �. �����.a �� diameter. Its health is good. Its structural � � s������� - > integrity is fair. � ��`�'� � � The proposed construction project would a�, ;� 4�, �� � ��` � remove this tree. � , ,.� �' P: ,,�i'�. � ,,°-i, , ,�4. � ,� �� � �,� :�, �,� ���, . �,����� t \ ',� ����' ',�`,, ,. e � ,�� ���� .,� '�a� �.Y• ro � � G��y , § s+�M6�v � ��+M �*�' r� � �r „� � . � � � � _ .^� "�°"�„� � r ��,�i�`u^ „� TM�.�, r.. . ��,:: �v� ,y�,;- ��' , . . �i:� .. �� a-� � ,����"�,��. ,� ,y� �"' ° . �� � ', � � � •. . _, ... +.;i�..;` _ .. � ,n "�n. Tree # 2 (in this photo on the right) is a w � ���° � �a g Coast Live Oak (Quercus agrifolia). The "�; � ��� � g ���Y , �, trunk of this tree measures l 8.2 inches � �.�` `� � .,� �..'��� �:��'� �:� � ���: DBH. The canopy is approximately 30 � , ` � . feet in height, and the canopy spread is �� � ��� � ��'-.�� ��. approximately 25 feet in diameter. ������� ���� '��� � � :�_� � �� �����`���� � ��������V d . � �� �,.s � ti�w�� ��, � � �.�,. ,�� A Prepared by Michael L. Bench, Consulting Arborist July 31, 2013 1 A Review of the Existing Trees at 10049 Imperial Avenue Cupertino, California The overall condition of Tree # 2 is quite good. The project proposes to transplant Tree # 2 into the new landscape. Tree # 3 is a California Pepper(Schinus molle). Its dual trunks were measured to be 13 and 10 inches DBH. The canopy is approximately 20 feet in height, and the canopy spread is approximately 25 feet in diameter. This tree is sub-dominant (growing out from under the canopy of)to Tree # 4. The plan shows to preserve this tree in the new landscape, but the proposed adjacent paving construction would likely damage the roots of this tree severely. I would not expect Tree # 3 to survive. Tree # 4 is a California Pepper(Schinus molle). Its dual trunks were measured to be 25 and l 8 inches DBH. The canopy is approximately 35 feet in height, and the canopy spread is approximately 50 feet in diameter. �a�.,�� i] �` '" �� �'i s . � ry' ; E :i �� Tree #4 has a serious fungus infection on � ;� � ` � the trunk, called Artist's Conk (Ganoderma , �� �,. � ,�,� applenatum) as seen in the photo to the left. �� '� , i ` 1� This fungus makes a hard woody shelf, but �� i , � ,` �.� � �-��� � r '�� � the underside is creamy white and soft. The �� � �b� �" � ` �� �� °° � �z.�� ��-.� <���� ` � ���� ��" red dust around it are the spores, which fly in �� �` �4 ) ' 1 �`, � ��t � , � the wind to infect other trees. „ . -,�, �'�,�,��,;�,� ��; . �.9, r�,���,�. ���� .. +��, r��. -- - �a � ���,�-. �� There is no treatment for this disease, which _ �' �' � , �,.�� �� ,��,� � �.,���i � � � . �.� , , a��., �, ���, � ��� typically will hollow out the interior of the ���" ������ � �� trunk until the tree falls over. The process is �. d +��.... �',W'. �..^ °�� � �w�.. : � ' slow and often takes several years, but it is � �� � . � � �# � � �"� inevitable. This disease is incurable. ;� � �,� , ��� �� ���� �.��� ��� ° �� � �'°� _- The plan shows to preserve this tree in the , � ,� �� � �'-�'�y ,-. �� ` �__��.. �x new landscape, but I recommend to remove �� � � ���� � � � � this tree for safety reasons. � � � �� ���° e ��� � ,�� � � ,{� � ��r�,��. ��:�, . „ . .�r�= �w����a..�.�� ��. � __ , Trees # 5, 6, 7, and 8 are all small young Flowering Pear (Pyrz�s calleryana `Aristocrat'). These have trunk diameters measured to be 5 or 6 inches DBH. The canopies are approximately 12 feet tall and approximately 15 feet wide. The plans propose to remove Trees # 5, 6, 7, and 8. Although these trees are relatively small, they were required to be planted when Monta Vista Market modified their parking lot over 10 years ago. Thus, Trees # 5, 6, 7, and 8 are protected trees. Their removal for this project would require replacement. Prepared by Michael L. Bench, Consulting Arborist July 31, 2013 2 A Review of the Existing Trees at 10049 Imperial Avenue Cupertino, California Recommendations 1. It would be essential that the transplanting of Tree # 2 be done by an experienced tree mover. Experienced tree movers include: Pacific Tree Moving (408) 231-7017 or(831) 475-6190 Environmental Design (831) 915-0358 John Arnaz Tree Movers (408) 266-1717 Valley Crest Tree Company(818) 367-5803 2. Per the protected tree ordinance, the removal of Trees# 1, 5, 6, 7, and 8 would require the replacement of 5- 24 inch box trees at least. I recommend that the replacements be planted in the new north side planter between the market and the project site, or in the west side planter. 3. If Trees# 3 and/or# 4 would be removed, they would require that 4- 24" boxed or 2- 36" boxed replacement trees be planted. Respectfully submitted, �----�---%.ed " e�_ Michael L. Bench, Consulting Arborist International Society of Arboriculture Certification # WE 1897 American Society of Consulting Arborists Member Prepared by Michael L. Bench, Consulting Arborist July 31, 2013 3 �'�":���-�I �.. ,A� �-�_�Zc►�3-� � � " t ,_. . ..,.< <,�..�,..�....�.. ,...�....-�. - ,y .. i ' ...._�i • �.. JV/ �-1� _�.� ._.a_-----=--.. �v�ry 1 �t-YC v.�?'� � /� � .i �RtST 'S�kiVal� _. R�'TP•tN�Nlx_1�+1aL..4" �J _ \�� � �'' � !�, � t � �.- .�. - _ �-'-"`_�_ _ .. ,_-- � /_,\ / 1 { �'� ��lCC-�o�P.i E7/i ��...._✓ i `�HtG��CiL-�__-_ �- �lE���:r� - Ta t�tA�.'tcrl� (TfV�SN� ---�Xl�'T11`i(JL- _l�Ll�(�t _ .� -� L./4lN.I2���4 kj ___ r� �T i �� // :�_;= �-� ./ _/,,. ;, �/ ._� - / � ., � - � � ,'��., � //� /'� � /, �,, �� � , -r;�, ����. �f�LQA17tNG A��A� � � � � �� � ,, �" j /�i i / � '! '� "// �� '� �/ i � �� , , , , , , , . . / - i� � �. �- � � , , , , �, , ._ I o� � ; �j i /��� �� � / �! � �� � J ,'/ e'� � J!'-I� .,�t�s�,�� �-�i �� ol � 1�S,o„ �.. . _. . --- AL K. ��F1C-FtG-7� � � I I > Tt�tST�L:_ rt..00KS - � � 9 N o R'M _ ��._._..._._._. � U �/�"=�'-�'' �; ���� -���...�.. ° _� _ -- ----_ I � ' .:�."- -� �.:. .' �� ,��, _.I' �,. )I _..' � �-WMw !' �, . �.,�u 7 ' �� y�.� III ._ .. ._. li�'� �y �. � � I�. ':MUMErook�p = �� � 1 ,`i%��. �� �� � _:�lau�etla:Or. �I _1Un1M ¢ _ 3 � � i�, a s a - ��rka� - �1N.�' �`i _ �y'�.� i� (11__""•�se�.pr�'�i���Ga� ���. � �A,�� �: -_ � � i . � � Q . },csesc� .. � ' � i ` �. 'i I � �..,. M� -���� ---a , -, �. , , '' ; ` ,�, � � � `1'�,.>4 t;;}., rw►.+� , ' * � _ �� ' "x••�•m u« � se�ae c,eek ewe-� ' =cuoern�o-Ra- , i � �,- —, � � �- � � ,see�em c�k s � ��,uc�°� '' i`",' ° �•, � ' ,) i�� � �I � � �. � � ' �I � � � !1 '� if F� 'i' �Ave— �� �ia�rmGOK T°i -i � !g � _ ' �� ��.�y Coursa �;� � n �eAnxa /r� � �. ?� � , 1�_ ;';: � 1 �j coueqe ';I. � y� 3� i� _ �i � ��� ��, II ' � Z F ���9 _� ,� � �+��`, �� �' R yy �Y 3 Palm Ave �i=-� , .,� I!) �- � .' .`� �.� 'L_ ;,_'. � ; � _ � ' ' � � __ _._ -- � .;>'� �eo�.-� �oc� �nrc dc ____ ►ac�un Re�- �� ��. �-,- ___. .. _ _ i, � _ I_ VICINITY MAP PROJECT NOTE Project is the demolition of an oider small house and garage and the construction of a new two story mixed use building with all new associated site and landacape work. PROJECT DATA 7,187. sq.ft. Lots size 1,825. sq.ft. Proposed new residence 451. sq.ft. Proposed new garage 1,525. sq.ft. Commercial space(includes 525 for medical) 3,801. sq.ft. Total space proposed 53% FAR 35 spaces Total existing parlring adjacent commercial building 35 spaces Total revised parking spaces New building parking required... 2 spaces Residential 4 spaces Commercial 3 spaces Medical 9 spaces Total spaces required 9 spaces Total spaces provided INDEX OF DRAWINGS Architectural: Sheet 1 Site Plan, Notes Sheet 2 First and Second Floor Plans Sheet 3 Exterior Elevations Sheet 4 Exterior Elevations Sheet 5 Sections Sheet 6 Street Elevation - Landscape: Sheet L 1.0 Hydrozone Plan O � � � � � � Sheet L 1.1 Irrigation Plan Sheet L2.0 Planting Plan AUG 2 3 2013 Sheet L3.0 Landscape Details Sheet L3.1 Landscape Details Sheet L4.0 Specifications B Civil Engi.neering: Sheet 1 Grading and Drainage Plan Sheet 2 Erosion Control Plan Sheet 3 Easement Plan Sheet 4 Demolition Plan Sheet S Off Site Improvement Plan Sheet 6 Best Management Practices RAY ROOKER ARCHITECT architecture interiors landacape 49410 Brian Ct. La Quinta,CA 92253 (760)564-6798 rrooker@dc.rr.com Cal.Lic.C9595 Consultants W � � O � w p�, � � O � � � � � 0 U ~ a3i � z � a � � a o 3 � � � o � � �� � � �� � O o� � o � �' Q � �� Date a-�o-�z iz.-i��-�z � a-�5 Sheet No. � 6 E � 4 't� � � .� II, � �,� I'. M ; Q= � �� �; i ij, '; i( � 1 � �' �� !O� ;�� 1! ii i I � i e , � c�' r �o � -- -------- - g�-_9��--- --— --���-0�� 20-�" 3a'-o" ; _. __-- - -------- —---_ ..------- , ---- - !�!����� - --- — - � _ -- � 12'_;�1e II 2!4� 3`_3" G`_O° 14`-3" ------- -------- ----- --.F}- _— -- --- ---- - - -- —-- --__- ____ _____.._ _--- --- `�°' ° — -- --.- � ___— ____ --- ____ ____ ----_.__ ___.__ ___. __.._ � i I { ____________.. _____.______._ .._._____ .�. ___.._ — (a� -'�Q%���0'`�_ -- / ,� __ p��rn � ���,-:__ –�__- i�" ����Y � *} � ��� �'� , ` �, \� � , � � :-' \��. � - i 1 _= i _._::_-='�i�TP�S_S�}?._.__. t_ __ � __ ____-- -- � � t'� .- -- --__ ——_.....__._. - — �� __ . _ ... ,,,,_..�....�........ _ .. ....��- � . �_ _� _. L�, � _-rx���r�=---: _-_ ------.,��.,.W-., k---1---e}---iE^— a°----�---"+`�"—^'t:-` --� � --t , �� i: I .� � �� �'�I� i�� t� ; ,''� �, rW �_�� � ` i �II i ; �� � I �i I , , . �, , � '� -_LVl_L t'3[C:A�. _.._ __. ..._......,.._._�� .. � - � � � ��� - _ 5�� SQ�: C��x } �.f I� I I s�:-a" �,-�� I l �� - � (t'I'` �\ �i � �/ � ��. . ,�._...� ,.,f.L__._.__1!.__.___ ��� ._......_.____.._.._.._....�.,_ _�' - �. — --T -- - _. , j ,._,._.��.._.-,�,�,:,,�y____._._____-- --k-__._____ - �_._T_ . ���., . —' i , . ;�-'�`� � ;��� , � .� ��'� �..�.+.._.�.'�`�..._" ' �y�.—�___..,.��;k.--�---.-__._.�._. ^' -�-+---. ��� , � � • � ( : � / ,,• �..\'' � � . 1 1 �L, ', �, �,i �--`�Y�---.. " � , � _ __ __ , r.-�----'--r --- ---� ,, _r . J °`S':O_F�-G1�G7A1;_- ----, — -���_ I t000 ao �i:(M tN�`•,..,\ � �� . �; , . __ ,� _ .'� ;� `. �. ,� f' �, , ., i __I__� � ? `C� � � T� P�'-Y vZ.c 13--c�I , ._ . _ `� ? t � . ,., . � � � -�7c�'� --� � . k ' � . � - - .....o,..�.'6 9-�.�-/� R.AY ROOKER ARCHITECT , �'� . _,.�..,. - arcinitecture �; interiora ` landacape 49410 Brian Ct. La Quinta,CA �1r�•E!� �G�'�f��f-T-�Q 1.1 92253 --- (760)564-6798 �� 3.�,x�' ���'..7 ��a.r=�.: nooker(a�dc.rr.com (� 2�r s' ;r� �� ,, (c� 3'F 4' �.-l. „_ � _ _ Cal.Lic.C9595 � Z�•�F IZ� - _. _:.__. .__... _ �4-z,� ,_." _„ _ _._ -�-- - __ ��) 2. r (t L� . � - g) 20,5,X Z�,. __4.r�! ' ��_ ,__._. .. ��77T�`�.. �`"'a�`�'s.;.�`��;.;.. ;�G.�-Cv_..�G]. f��"" ���_f�_.__�G���7�'...�`1=0 ���J .V=Lt�a--- �l�f�!���l�t� _—.. _ f�RE'� �"R�V L�T';o� (,4? 44' �'37� 1�8 0.�sca F'T' �6!\ i.�i�_„�r� __��. ` . �,. �- �- i.�1-� �,-�..bJ� .. . . ..�r�l "�� " . . . .. .. . i%r�i._ �iS V!�r�°.f; 'k_,.�./.�:.,, ?+Aj R� :s Q, F'". I � TRC-L.�15 3� ► - -�1. �� �' � � � et-t'F h'tY��Z � ) _ �o� t--�o�"T� . - �--�-- -�-—...--: I I I � No KTK �( --- -___ _ �� .���_� .__�.���.�'�__ ���� ��`-_t'-o�, � COII8llit8Tit8 W � 0 ti �° � •� � o � � � m � 0 U � z W � �¢ a� � a o 3 � �. �o �i 0 �� � � cC � �A w � o� � O � � � � �� Date H-to•t2 Revisions I� l2-�? IZ Z -'2�?T3 =--- p�-�'�-i3 _ Sheet No. � 6 _ �°�:�.�.��� r i ., ,.- �. ,- � � � ��L � . _ t�. .n =_.� .._���.�.�����n, `�" �'� �-i��_ _ . �� , � y I _.. —� _, _.:._ .�. ' 1M ����� � ���a r �56(-.1T31��T5.-�::--:.._._ ___ • (.� �o�� ����o K�►]ula�`y /� ^f�ll:.�7�1 it�+ 1► =r-_�►�r� �r� � •�r � �:rl � " • 1 ,� � ,,_ RAY ROOKER ARCHITECT archntecture latesio7s landecape 49410 Brian Ct. La Quinta,CA '� 92253 (760)564-6798 trookerQdc.rr.com Cal.Lic.C9595 Consultants W � � w � o � � .� � � � � � � � �/ . '�l"' W M � � � a 3 � � +� �--� � �^ � �'o �� � � o� � 0 ��� � Q � U� Date � _T�t.�Li Ai,'�oS1 L Lo�K.�L-� ii-1�•I L Revisions y [� l2-t'7-�2 n 3-Il- �3 � �_V�-1'► R�F.R 1''p�1�KtNC� � .�` ^.� -� 1. �'..,.r . '"-r � � Sheet No. � � � . � �� �.� j oE �'o :"_:-�_l� ,._........_.....a..,�..��.._ �►o-���3-.`.�I F ,.. . ... F,. . ' "'� .. '.,. , ..��� -,��C3-{:�,� �-G'� _ . �� /�-�� E� -�--- L�� :s�..�:.;.� ,; . _. ... .... _.,, -_-�I�ti��'e Ca. _._ _.. ``�� KL�A.�.-::1�7tJZL'T�_ ���� ��/��� A , �,'SLCI'lc)N RAY ROOKER ARCHITECT asctaitecture intesiora landscape 49410 Brian Ct. La Quinta,CA 92253 (760)564-6798 irookerQdc.n.com Cal.Lic.C9595 Consultants � � ����t�T:_L�S-a��aa f�►.��Q �o�°�� ����o W °' O ti w � •� � O � � d- � � U ~ aai � z w � �¢ � � a 3 � � � �""� o � �1 �, � aA U � O ,� c� � � a�'i Q O �� Date y-It�•12� Revisions � It-I"]-IZ 'y—�l-13 Qi �-�-t3 Sheet No. �� �.� � � � 1 U _._..--- .. ____._. — - -__-.T�%��----- --a� rc._--_._.. _ �j,,_..t3FVRr�r_;- ::t_- ��._____:_-,- � � � , _ �,_ _ __ � -� _ _ ��,_- I � Y y � uj j ; �� ! 'I ; ' ____�����--- ____.__:�ci�r�.r:.[�_�:_�._;,_ o I ``� -a„�� I�� i � � � �r� L 1y � Zi '`, ---t�rP�l�[�iL.:"��--_ i�. N 1� � � �l !�� �! �� � '�� �� � �_-� � �; ��� ��C�'�'�O� `���' `��``=�'-°`' � �� K►H Gr _ __ _ :_ _1.�:. ____ ._.._....._-._._ �i b �n o� ��������1 Q�� 'r�"-l'-o'` � . . __. _ p��-�1�-c>I ,r , . � � � - � � �- .:. - ; .�... �, ia��:/3. .�? ��.�_. ROOKER �— /���' ARCHITECT __ � . — archntecture _.. . :,. .,__:,_,:. inieriora ` ��-•- -- landacape �--� " 49410 Brian Ct. La Quinta,CA 92253 (760) 564-6798 rrooker@dc.rr.com Cal.Lic.C9595 Consultants � � W � � w � � � o .� � � � �� N zw � W � � a � 3 � � � " 1--� o� r.� � �` au �A � � o� � � �� � � O �,-- Q � �� Date y-�o.tz Revisions IQ 12-t"i-!L /� "7-8�t3 Sheet No. � � �` •�� ^� � � _ �- , �: . �- i � � ' I Ir�,r � ��� J� I , � , ��, ,, ; ,__ � — ----�� — �� 'i �-,,-..-�:�--� :� � .�`=_::--- - —= �----—---_- = �_-- � � �_�—� ��-� �!l� � - �_ - � � �� �i, -=� — -- ��_ _ - -- � ,�_ � - — ��- , . , '' i � - _ -,, ir^� ���' :- - � � i � � _ � III _- � J 'r � L= ��� -- - ..-. _ � �� - �-- ..---- ,s�=�.,,�.,.:�---��=; .�—- ��, `. , �� � � � i�, ��f '� _,7, � ��� � i��-rL���.-�'------- --- �� ^ l� ± `� �� �-1 � �•.,•r , ; r �`'`°�r�.�'�-'�, � � , , �'a, � � ____-; '� 's'-��� � `' �-�-_-��=� -�- __ _ :., i ��- _ �,� ;� �_� _ — ���_��� _ ,,�,��_-,_,�!— � �... - -----__.�i' ;� � ry �����L� �`��M �O ������ ����i ����� ���-�T"''`�'�� 1 .� �,-�'D� i-�s.�_ _ .�;,� ��l",>�,�—(;� ��:,;r:�__.�.�:�� ,�use,��r . �i—��—�3 �p ,:._,_ : . . . ,... a:� I i i I I i €�1�'��.�1�°E?I Fw `����0 k� '.�#�_.��..`�y--�.�� ' � .. � � � � ��i�f��e..L�,'Y.�'i� _ . �_ ._....r.�..... � �:, - - - �:� ... �-1� - - - - -I �'`,,.,,;�, .�.., -,-, �t�s:c..il.+:t:i W � Q � � � �/'� LL L O� MAWA MAWA=IEToJ x lOb2)x ll0.l x LA)�l03 x SLA)) MAWA= 38,635 galbns/year em a 45.3 hydro-zone plarrt water use hydro-zone area ETWU 1 LOW 486 9,555 2 LOW 650 1,304 3 LOW 365 8,531 4 LOW 500 12,482 $ MEDIUM 344 6,763 2,345 38,635 �U ES?IMATED WATER U5E IETUAJ) ETWU= IEToJ x 10b2)x(��E�"�'4 .SLA) � ETWU= 18,907 gallonstyear eto= 45.3 h dro-zone irrigation hydro-zone plant water use plarrt factor y area PFxHA eff���, ETWU 1 LOW 0.2 486 97 0.85 3,212 2 LOW 0.2 650 130 0.85 4296 3 LOW 0.2 365 73 0.85 2,412 4 LOW 0.2 500 100 0.85 3,304 5 MEDIUM 0.5 344 172 0.85 5,683 TOTAL 2,345 572 18,907 HYDRO ZONE LECEND IRRIGATION HYDRO-ZONE LEGEND PLANTS ARE GROUP TO HAvE MATGNINCx WATER REQUIREMENTS AND MICRO-CLIMAtE CNARACTERISTICS. HOH WATER�IuENT 0 SP. TURF + MEDIUM WAT�i�MENT + + 344 SF. + SNRUB/GROUND GOVER AREA ���� 0° LOW WATER RE�II�AENT(DROUGFiT TOLERANT PLANITING) � ; 0 2�D01 5F. SNRUB/GROUND GOVER AREA PROJECT DETAILS ilENOVATED LANDSGAPE AREA TOTAL- 2,345 SP. IRRICaAtION IUATER SOURGE-MUNICIPAL WATER WITN IRRIGA710N WATER ME?ER ,�r"�-'�,�U �i il i �I i � i il i! PLANTING AND IRRIGATION STATEMENT �;��'i�,i,'�,','�,I„��;I,II���'',';,,� i illV i'Iiu��,,, �i� 1. I I-IAVE GOMPLIED IUITH THE GRITERIA OF THE WATER GONSERvATION IN LANDSGAPING ORDINANGE AND PLLIED TI-IEM FOR TI-{E EPFIGIENT USE OF IUATER IN THE LANDSGAPE DESICsN PLAN. 0 5 t0 20 2. I NAVE GOMPLIED UJITH TNE CRITERIA OF THE IUATER GONSERVATION IN THE LAND3GAQING ORDINANG AND APPLIED TµEM AGCORDINGLY FOR THE sceb�•=�on EFFIGIENT USE OF WATER IN TNE IRRIGATION DESICsN PLAN. 'rox°�°'24x� REED ASSOCIATES UWDSCAPE ARCHITECTURE ♦n sami r�r� sraEEr SUNNYVALE,CALIFOWlIA 41088 �oe.�si-eozoisoe.�ei-soxz Froc .w:....�n.�i«ru�:w�e�.nr MIXED-USE COMMERCIAL 10049 IMPERIAL AVE. CUPERTINO, CA ISSUE DATE REVISIONS 08.23.13 ����. � � � PAUL JAY REED � a No.2002 � * Exv.ai�Oro # s� P 9TP ¢���� OWNERSMIP AND USE OF DOCUMENTS N Wa�inqe.Specifcalione and copn Mer+uf/urniahed Dy ReeA Mwciat„�dqKq�e ArcNt�ctun an anA ahoX remain it�pro�wrty.TMY rn W Ee uaW ony rim rnDrt to Mis Projxt rnd oro not to be uasd on ony oNSr projxt. $ubmitsion or diaMibution b mHt afficial rogula4ary n— quiremeMe or for pu�poses'n connection with t�e Proj�cl i�ml to M caWru�d m p�kolion in Owoqalion of Rasd Aseaido LaMxoW Nchileclwe.common laM�opY^9M w otMr remrved righU. ApDroved PJR Drawn NC Reviewed PJR Project No. 13.08 Sca1e 1"=10� Issue Date 02.15.13 HYDROZONE PLAN L1 . 0 sn.e� of � �__ � ,� 1 `, � , � / ���/ � / ��� / � _ --_ I •I I _ � I I � I I.� �_ � i i i i I I � - - - - - I I o�sn�MnrirF -� VH2FY LOGATpN N FBD. � � ��'��3'�=� I ,"'...,,�•';"n-``'J•, i. ��, ..- . .Y.��.� ,���1��,�.�z���.���o`�._..s ' - - - - - - - - - - - - �-�� - - , - - - - � l�—!� I - . ._.._._ _. r_ _ _. ,. I � I � � � . , . .. . ..,,: ,_._._., _ � � I � � \ � � � � AD,AIST E)fISTNf6 RRIGA1qN TO PROVDE RA�CAV6tAGE. A5���. W / � ' J Q � W/� I..i� L CONNECTION Td IRRIGATION WATER METER(WATER(��IETER BY OTHERS) IRR.B.F.P TO BEILOCATED WITHIN AN ENCLOSURE WITH A CONCRETE BASE AND LOCKABLE FRE E PROTECTION BLANKET. ' ENSURE DEVIC�COMPLIES WITH ALL LOCAL AND CITI�CODES AND ORD. i O F�iIC1Al10N PPE SRN�CI CFiART CLASS 200 �F�U�40 CLASS 315 •INTERMITTENT-PRESSURE •CONSTANT PRESSURE PIPING •CONSTANT PRESSURE PIPING LATERAL PIPING I-I/2 INGI-IES AND SMALLER. 2 INCNES AND I.ARGER. I/2" _° O-4 GPM �INTERMITTENT-PRESSURE 3/4' -• 5-9 GPM LATERAL PIPiNG �^ -• 10-16 GPM � .. 9_��pM 2" ° 31-48 GPM I-I/4" �• 17-26 GPM �-I/4" •• 16-22 GPM 2-V2� " 49-65 GPM I-I/2" -' 27-35 GPM i-I/2" ° 23-30 GPM 3" ° 66-b0 GPM Z^ _= 36-55 GPM MONTNLY MAINTENANCE SCHEDULE ,.,.. �.�,.�,�. - --- �.,� ��.�„�.. o 0 0 . o w.,�.a �� RUl11 R1R!YD 16L�C!0lCIM1!Mp�l6 • � 18IIPAlIW D ID6 166!�1000 8'.lJLI�!O DA16. • � ♦ x��D er wuo•e xa�e�a xmc • • , • • • • wma.+a.ew.ro aeae.�e�e ur.rws. . • , W Wli p.10V!YO�IIL!0l10 R.M�16�6 n!�'!!�P'. �� 14D1 IG1l�N 1110.�BPOi. 1BL/4!�6��. o,,,,,a ��m..�,���.� . . . . . no.ao ww�.w�»�..e�. . , . , . . . . . , . . . .c+��o� p .nw m��Mawa m�s�..uaws DRIP IRRIGATION NOTES L REF82 TO DRIP N2RIGATION DETAILS FOR TI-E LAYOUT AND EXACT DMBdSIONS FOR TI-E DRIP L1l�E. TNE DRIP LJh�SHALL BE A MAXIMUM OF 18" APART AND SLaALL BE A MAXIMUM OF 4"FROM ALL WALKS.GURBS ArD WALLS. THE NUMBER OF DRP IJt�ES SHOWN ON PLANS MAY NOT RERECT TI-E ACTUAL f�A1�vBH2 REGIUIRED,TI-E SPAGNG GUDE SNALL TAKE PREGEDHJGE.DRP EMITTER UrES SNALL BE ALIGPED TO uAVE A STAGGERED TRIANC'�ULAR F1vMTT62 LAYOUT PATTS2N. 2, TFE SUPP�Y l-IEADER APD EXI-IAUST L�ADER,W�-EN PVC,S�IALL BE BURIED AT A MINMUM OF I2"B�OW GRADE. 3. INSTALL THE AUTOMATIC AR R�EF VALVE AT THE NIGHEST POINT ON EACN GRCUT OR AS DIRECTED BY TIaE PRO.�CT LAI�DSGAPE ARCI-#TECT. IRRIGATION NOTES LECEND O LOGATE f2pGA110N MPf�1rE CTD f2�GAT10N VN.VES N IS�I�DSCI�PE tY2F1�S. Ml RRIGATION VALVES TO 8E LOCAT�N SPECF�V41VE BOX N 51-RlB PIAMNG AREAS ON.Y. �LIMD TfB�A 11 ALL(�16ATION MAr1PE GAD LAT62PL II�ES LOCATID PF1�R D051NG 152� R00T ZOrES. IRRIGATION LEGEND :�� r .�� �,�'�F��v_RrE���,"l/ 4 �� � � � :e� � ,��A �� �f�� 2��, �� . _, . �.���,_ � � _ _ �+�.��'-A,}A� � REED ASSOCIATES LANDSCAPE ARCHITECNRE 4T7 SOUTH TAAFFE STREET SUNNWALE. CALIFOWiIA 9�OB8 �ae.�e��soxoiaae.�ei�eozsF�z w/e:w.w.ral�.r�t i�il:p�ull�al�nM MIXED—USE COMMERCIAL 10049 IMPERIAL AVE. CUPERTINO, CA ISSUE DATE � �viswNS 0l.25.13 ����� N �, (�PAUL JAY REED(� gi No.2002 � * exv.aijoro # ST P 9rF ¢���� OWNERSNIP ANO USE OF DOCUMENTS AN Draixqe,Spedficatione ond copisa Mersof�umiehed Dy , ReeE Maorioly LnM�cupa NMitecture oro an0 efaY rerta� �b wew�y.n�.y o�.w w�s.a o�y w�m roavct eo me Projxl and arc not to De ussd on any oMx projxt. Submin'an or distribution to m�et officbi nqulatory rr QuiremenU or for purpoeen'n connection with t�e Proj¢t is not to W corMru�d as puElicoliu�In MroqaCqn ot Rsad Awocidee LmOSCape Mchitactun.rnmmon law copy�iqhl w other reaervad riqhh. Approved PJR Drawn NG Reviewed PJR �. Projsct No. 13.06 Scole 1"=10� Issue Date 02.15.13 IRRIGATION PLAN L1 . 1 Sneet of / �/ � GI ( / --- � , �_ - � � � \ � 1 � � � � �, i/ i i i i , I i .--, �-�� �� GI � �1 GI ' � --- � . �� � • C-r4 ` � G4 .� .. !... 4 .... ..i�\ - f� � \��i ��� 54 V2 V2 V2 S3 G5 4i n i i i �a ss ._-------_ 6 � I . ��K�,;:��.-�>� - - - - - - - - ��' -.� ��'1�°D� ��; �� , � �_ � . - - - - �. _ . _ ..: I — . . . ., . .. �1 /�-C� �_�,,..�. _,. _ ._ , �- ,,,;.... � � .. ._ . �.. � � �~_ . _ ,: ._ _ , . �..�_ I I , � I 3'DEEP MULCH (E)PLANdS TO REMAIN W / Q J Q � W^ 1..1.. � PLANIT L.IST� PLAI�(T NOTES L TI-E CONTRACTOR S�IALL VEi2FY PLANT QUANTfTES FROM TI-E PI-ANTNG PLL�N.QUANTRES SI-IOWN NJ TI-E LEC�D ARE FOR GONVB�3Jf'�E OrLY. 2 NOTFY TI-E LArDSGAPE ARCNTECT�M�IATaY N TFE EVBdT OF ANY DISCREPANCES BETWEEN ACTUAL 51TE GOPD�TIONS APD Tl-E PLAN7NG DLAN. 3. PLANT GROUrDCOV62 N SFRL�AREAS AS NOTED,USE TRIANGULAR SPACJNG. 4. SEE DETAL APD SPECFICATION S�EETS FOR ADOITIONAL�FORMATIOfd. 5. TF�RE WI..�gE Np MAT�IALS OR PLANT MAT621ALS SIJBSTIMIONS Wffl-I011T APPROVAL OF TI�E OWrER OR TI-E LAPDSGAPE ARCNTECT. 6. ALL SLOPES PLANT�WIT1d LAWN NOT TO EXG�A 31 SLOPE ALL SLOPES PLANTED WITIa GROIJ�D GOV82 NOT TO EXC�ED A 2d SIOPE 7. PROVDE POSITIVE ORANA6E AWAY FROM ALL BULDNGS(2E Mr1) 8. N TF�E EVENT OF ANY D�ANCES BETIN�N T4a5 PLAN MD ACTUAL 51TE COPDITIONS,TI-E LAt�'.�CAPE ARGNTECT IS TO BE NOTFIF�hNv�IATBY. 9. BJTRE SITE IS TO BE ROUGN GRAD�BY Tl-E 6RADNC'CONTT2AGTOR TO WfTIN F00T OF RNSN C'iRADE LArD�'aCAPE CONTRACTOR IS TO�E GRADE ALL L4rD5CAPE AREAS. 10. All SfTE UTkJT1E5 ARE TO BE PROTEG'f�DI.RING CONSTRUGTION. W T4�E EVBJT OF COrFLIGT gETyyEBJ Tl-E P�AN$ArD UTIffES TI-E CONTRACTOR SNALL N01FY TI-E LAt�'aCAPE AR(�ITECT. AN'f DAMA6E TO UTLITES.STRUGTLRES,OR OTl-H2 FEATlRES TO REMAN,ArD CAUE�BY TI-E LArDSCAPE CONTRACTOR SNALL BE R�LAC�OR R�ARED BY TI-E CONTRACTOR AT NO E)(PB�SE TO TI-E OWPER. p 11-E WORK N T4E$E DRAWN6S APD$PEC'.FICATIONS MY Rl�l CONClX2RBdTLY WITV�1 WORK BY OTl-ERS. TFE LArDSCAPE COMRACTOR SNALL COORDNAiE TI-E WORK WIT1-I OTl�2 CONTRACTORS. YL. PRIOR TO AN1"DIGI'�NG OR TRENG-NG.CALL I rI)FPl',Prnf�SERVICE ALERT-L800.227.2600 13. PROTECT EXISTNG 5T02M DRAN N.ETS DRAN NFTS,WITH RITH2 FABRIC,FOR TI-E DIRATION OF TI-E PROJECT. KEY LEGEND �Q - �r�s�raa�-..�cr�t�-►'naza ava�nT�c'.�Fa��ca5n2� � - ��-Ffl2 N�NfA�1vTA G£�C�l 0.1C8Jf�ES FC�21 03 - ElGiQF R�lK-BY OTI-8?`� 40 - �F1'��L1C�-fT-I-l�X'.O C52�dCKA(1CCl�V M-t 12CM,17 FCI�P4C1.30 RN9-k��C1C AV��T1-f�tJ�-I EIM�1'.If�AT 4CQ3422461 CR 5'l.�82�2140 �..i�i�r s�s ( aoo-rz�-2soo �CATES PLANT KEY �� 5x � x IN�ICATES PLANT QUANTITY /� \ I . � EXISTIN6 TREE TO REMAIN \ � �_i I�x\� EXISTING TREE TO BE REMOVED � � ,_, �' �'���'i�� p, ��i� ��i n ,'I ' I����I I��I li,�i„ ���,I� I�i�,j�,iii����� �� � 5 ,� 20 Scale 1'.10 ft shest dza-24'�CiB' REED ASSOCIATES LANDSCAPE ARCHITECTURE ♦n sourH ra�r� s�Er SUNNWALE,CALIFOF711A 91088 �oe.sei-sozo i�oe.�si-sozz r�x vwb:wM..da�rt i�rWl:0�0�� MIXED-USE COMMERCIAL 10049 IMPERIAL AVE. CUPERTINO, CA issue oAr� REVISIONS 08.25.13 ����� y - �PAUI JAY REED� i�..�Z y * E%P.9/30/q * Sl P 9T �,¢� F(���\W OWNERSHIP ANO USE OF DOCUMENTS AX Drawirqe.SpaNlicationa and copee Mereof fumiePad Dy RaaA bsoGial!!lAndscapf 14Chit![tlXe oro aM lllall rMqil ib vroWrty.TPay ar.to be uaW onN wiM rasp�ct to Mq Projxt antl ara nM to be useE on any other project. Submi»ion or dietribution to m��t oHicial r�qulatory rr quiremante or for O�rposee in connxtion with tha � Pfpf�Ct if M�SO�CMiiNb 0���4�M��1�� Rsed Neaiato LaWxape MchilecNro.comrtan la�coq�i9ht w other re»rvad righU. ApproveE PJR Drawn NG Reviewed PJR .. Project No. 13.06 Scale 1°=20' Issue Date 02.15.13 PLANTING PLAN L2 . 0 snaet of NOZZLE,AS REaD.e Y �—RADIUS AND PATTERN �FINISI-I GRADE ASR�SPEGIREDAD �-MARLEX STREET ELLS NIPPLE,SCN / �RISER,6CN 80 LATERAL LINE,PVG/ � � MARLEX STREET ELL TEE OR ELBOW FITTING,SCN 40 � 1 � IRRIGATION HEAD DETAIL FACfORY Ctlf TIERWIL O�AN810N SLIP JOWf ,���„� 87EELW1NiPIN, 9EE CYiART FOR WID711 BQIDA BONiD PlA3f1Cl/EIIOER BQ�ND.8EE Cl1ARf Fqt SIffB 9EE dNRi ruar�c ar� Faa THVaM� o�o.c.wuc ueE r owiweia+c�r rureo oEac scs�ws FOR ATTAOI�ENT F�p FlIIRSN ORAOE �� oaou�o covEa T� =u __ wwm+cu�rs } u�w ��-,,.-i=i i �i�-�i-�i seecawrrron 1 __ - wwwuw �I _- li a�oKrs -i ii- _ - SECTION I�i PLAN VIEW ww►axa rr�w��u r+�++� suv,ron+r �ort �cnu� n�aue cxovrd ow�rreaa wvr� 91� DMEN810P6 POBeBIE POHBIBLE GAP AT 9JP JOINT�� au ay�xiye�:m x� ie��xa 1?-311' 71?IDx17 ����� �.oo wor sciew nriaroN w�o�tr �w�rew'r wP 3.U9E C011RBE VYOOO WONIOM6700L8 wn cunwa a oa�wo ].lBE PI.AlED 9CI�w8 OR RNIO B�MN( _ rwisroao�ewroroar� - - �.KLOW PoR 71Efi111L EJ�AN&ON i COMIRK.'f1ON _ � _ BV LEAVNC C.M8 N111F BLIP JdN15 OR ATl/E ETO -_ - OFTNEPoIIJ(BEECII�Rf) '. - - Poi i w�rw w�n�uer�u Mx+wa _ can wewr�irer�u w�x aw �a� 6.8TA1�APVNOK 3 O OC 1�FOR B�A/JOM RUNB (LLLVIW�D LE88FORGURVE9) S1ffLYNINPMI, I I - SEE CFNRT BENDA BOARD FO""� --',i' - �OR��N1OREOiYOOD SLIP JOINT DETAII w�w��crur�u ev:m�c Puencs.+a Fwsr rwtn Ao..�oa a aszio ua�oo�ss:rww..awo�.uo.mm 5 'BENDABOARD' LAWN HEADER(OR EQUAL)DETAIL ——� _� � � � � � � � � � � � � C,B�ERAL NOTES OBUIIJNC,PAVEI.�B�fi�GE OR LAWN I-EADH2 2O �xarv covez az suxs vuwrr� O3 E�.•EQUAL qSTANCE. 5�PLANT IJST FOR Df.�EN510N 9 I GROUND COVER SPACING 4�� Ul� 3M-ELEGTRIGAL 500-09964 DIRECT BURY SPLIGE KIT DBR INSTALL PER MANUFACTURER'S INSTRUC?!ONS AND 4LL oPPLIC GGDES REMOTE GONTROL VALVE. 'IRRITROL'700 SERIES"ULTRA-FL OMNI-REG BY IRRITROL(MOR-100) ON DRIP VALVES ONLY. SCNL40 PVC VALVE BOX,'NDS-PRn'VALVE BOX c214BGD8l WITN BOLT DOWN LID�OR EOUAL. �N rRADE F'CH VKHVCL�VIVI1' CONTROL VALVE DETAIL 2AL LINE, 40 PvG W �°�TIE a � TRE�S POL� �'SET RogOT CR�WN AT �GRADE OVE FI ISN TIE � EARTN gERM �MULCF-1.I-I/2"DEEP � AkOUNC ROv i 6ALL I W 3"I-IIGN MIN. p�,iC CAP � wi GRATE FINISN vRADE �� --I I _ - 3m d�g -- ' ROOTBAIL SPEGIFICA�TION) V2 D -- � � PVG PIPE.PERFORATED 4"DIA.X 36"LONG -EXISTING SUBGRADE 2X DIA.ROOTBALL TREE PLANIING DETAIL NTS aANCsER�µUGTF 4X8) �TR�Nr3ER'�'�2"�.G. TRINCsERS TO RAFTERS� 4"X S"RAFTEF2 l30"O.GJ 4"X 8"BEAI"f 4"X C"POST�� 1"X 4"TRIM — � PLAN � SIMPSON POST BASE 1G84roJ PER PLAN NOTE: TRELLIS TO BE MADE OF DOUCsLAS FIR WITI-4 l2J COATS i � OF SEMI tRANSPARAN7 OLYMPIC STAIN_COLOR TBD BY OUINER. TRELLIS DETAIL VALVE BOX,GARSON 610 � nSICSPE�FIEDR VALVE, i —TURF RISER.SGN 80 PVG � MARLEX STREET ELL� �4BSECU EKW/3WORM�-G AR CLAMP RISER,SCN 80 PVC 3 I QUICK-COUPLER DETAIL TEE OR ELBOW FITTIN6, 5GN 40 PVC LATERAL LINE, GL 200 PVC 'DEEPROOT' BARRIER N.TA. � SI�EWALK "DEEPROOT"BARRIER (UB-24-2) �--TREE ,-GURB -�-3'm�—i-m� � SIDE W ALK TOP OF'DEEPR00T'BARRIER MUST BE AT LEAST U2' ABOVE GRADE GROUND LOGKS �� / / NOTES� � I.INSTALL'ROOT BARRIER'WNERE EDGE OF TREE IS LOGATED WI?NIN 5'-O"OF WALK OR GURB. 2.LWEAR BARRIER 54-IALL BE'DEEPROOT BARRIER' (UB-24-2) 3.DEEP ROOT PARNERS,LP. 530 WASNINGTON ST. SAN FRANGISCO.GA 94111 (415)781-9700 4.CENTER ROOT BARRIER ON TREE AND PROVIDE PROTEGTION FOR A MINIMUM OF 10'-0"LINEAR FEET. 7 I TREE ROOT BARRIER DETAIL 4" X 4" STRINCsER � Im" O.G. ��- 4" X 8" RAFT�R 4" X l�" PR�SSURE TR�AT�D POST PROVIDE I-IEA�/Y DUTl' NINCs�S AND CsATE LATC1-! f" X �" tREX - OvER 3/4" EXT�RIOR PL1" 11 I TRASH ENCLOSURE SCREEN/TRELLIS •�-suaac-ew e+aosu� � -825TA IL AL� l � � I I • I � � I j I � I I j I I � � I i � " i I a r�E��5 I o I � I I �a.� � � I � � � � ..�,_I'.�.' __J-_ --_t-_11�J�_1J-__i--_--��_ V i � �� �. ' m -, r �,. „ , , -- , .s a�na.e�o.c. aa'sanse�aocicnc� S�F�/C � � ���TFRIIuT � � r�0�E5 l ASSEMBLY TO BE 3'-O'(MINJ FROM PAVED AREAS. Z SIEH PPE.IOINT COMPOIf�D ORT EQUAWITH'P62MATEX' ���e-�E�o�''u�A�B�E B.�&c. 4 BACKFLOW PREVENTER DETAIL SNRUB PLANT REED ASSOCIATES LANDSCAPE ARCHITECTURE an sam+ rnn� sTaeEr SUrNWALE, CALIFORNIA 9�OB8 �oe.�e+-vo:o i�oe.�ei-sozx F�x w�.e:w�w.nrnM i«�il:p�ulaW�w MIXED—USE COMMERCIAL 10049 IMPERIAL AVE. CUPERTINO, CA ISSUE DATE REVISIONS 08.25.13 �����. tn - �PAUL JAY REED� No.2002 ., * E7(D.9/30/q * - BARK MULCN 80 (3"�MIN. Sf �aP 9T _ry: ,/ CREATE SAUCER WITN TOPSOIL 150 (6")MIN. ��CA1-�w /!ii!ii� �i!!i7�!i� _ - -r�'- - GENTLY GOMPAGTED TOPSOIL MIx1URE - ,�.i�.J TAMPED ADMIXTUQE BAGKFI�L -n ='� fr�'��/a/ �a1NNERSHIP AND USE OF DOCUMENTS 2X BALL DIA.MIN. �� N proNinqe. if iona and copea thereof fwniehed Dy ^.. �.., ; � r� � R n ape Mc�ifsctwe an anE aMX ranan . . ..� �,�-,j� � � ih .. to b�urd ony wiM nap�ct to Mu �''� � �..aa s.. ., saE on any other pro�xt. -Y" ' `"`@"��"+r �� ��t �Submisiron or distributbn W ma�t official rogulatory rr , 'P'�yil�Melejita or for purposee'n connxtion with t�e -�� - •'�` �'c16Jk.t•'t not to n.caatru.a as p�n�kauon in a..oqotion or ` Resd Maiotn Landscaps McAiteclure.comrtan larv copyriqht C�-J/7_% � w oMer raeeneE riqhte. /"J '�r . . ....APA�,_4Y0� P� r..., . .,.. ..._ :.._ .. Orown NG Reviewed PJR �- Projeet No. 13.08 �e-- Issue Date 02.15.13 ..�.�r SHRUB PLANTING DETAIL ;�,°� r•a•ctuFx oECiwG� B�.MGED PLAN VEiM DETl+1 ror ro er.re 6' 2' 6" B.EVAl10N �� rar ro+v+s l IIiX D.pOAf057 fiQOMg.�C�8Q IApVA QQ.'7C W.OR1 9lEMf BN.pIE FOfi OMT6�8 OFP40VIL Z PIO 90�Y�$TNT1�Cp.OQ 70 EE�ffB71C EIAGK'�C'f81GE ] FA57BS�'9 STN1E55 5T�q GQ!7CM IF/iD 5(8M'S OGE SQiM�MO TE FACE OF T{E �BCE BOKOG.70Rx O��F SCGEwG wLL 67GD pR 1P55 71W�54UNg piNE. SCREEN/ FENCE DETAIL ��� �ssi.a�� �� LANDSCAPE CONSTRUCTION DETAILS L3 . 0 Sheet of TOP OF MULCN 6-INGN ROUND VALVE BOX� �RAIN BIRD VB-6RND AIR REUEF VALVE KIT� RAIN BIRD XI7000 AR VALVE KIT GRADE APE DRIPLI� TUBING _' �_ � -, _ U �3-INCN MINIMUM�EPTH OF 3/4-INCH WASNED GRAVEL 1 DRIP LINE AIR RELEIF VALE COIALNG-RAN BRD'(MDCFCOIA) �RUSEI CAP-RAN BRD'MY�CFCA?) T2PN BRD'(600-GF-D AD�T6�Mp�T�PV�C T�,��i AN ABS TO PVG BOrDNG SOLVB�ff ARNACl4�A RB..�VALVE 'RqN BRp'AR VALVE KR QJSTALL AT FaGI-I PONT N LAPD�.�CAPE SYSTBd1 LMDr,�CAPE DRPL�E Tl6NC' PVC SGN 40 aI.PPLY LAT�AL LDE VALVE W1TH CONTROL ZOrE KIT �RR.MAN.�SUPPI.Y PPE SIAGLY I-EADH2 PVC SCH 40 N?T41 COAdPRE5SI0N FfTTNG�r 'RAN BRd f600-C.F-D 5 DRIP LINE IRRIGATION DETAIL TOP OF MULCN 6-INCN ROUND VALVE BOX� �RAIN BIRD VB-6RND � �FINISN GRADE FLUSN CAP 'RAINBIRD'(MDCFCAP) —LAN�SCAPE DRIPLINE TUBING OR 1/2-INCN POLYETNYLENE PIPE - ', - ;�,:—�r_-'•,ru �3-INGN MINIMUM DEPTN OF 3/b-INCN WASNED 6RAVEL 9 I FLUSH POINT DETAIL 9p NCFI IfEAR LENGTI-I WIRE.COLED TOP OF MULCFI FIJSF�I GRADE�� SCLJ.40 CVC VALVE BOX,TDS-PRO'VALVE BOX(2k18CDB) WITN BOLT DOWN LD.OR EQUAL. waraz caooF ca�cnor� �zarrenzo scuce-r GON7ROL ZO�KfT� (NCLIAES BALL VALVE. VAVLE.BASKET FI.T�ArD PRESaURE REGU-ATOR) E PVC LATERAL LrE i� 3-NCEI tiNMUM D�TI-I OF 3/4-fJCl�l WA54ED GRAV� SCFJ.40 PVC MAI�L� DRIP LINE CONTROL ZONE KIT DETAIL NOTES� ��INSTALL BUBBLER 480VE ROOT BALL 2�MSTALL BUBBLER ON UPWIL SIDE OF PL4NT WLIERE APPLICABLE. BUBBLER� /��2^gTREET ELL STEM 48"MAX WATERIN6 BERM I/z c�LC �R c FL FINSI-I GRADE HOSEp(LEN�GHT AS REPUIRED� - -- � 12'MNJ.COVER � �I � I''h� ?�)�.� I ROOT BALL=---{� . /` . �� �T 1 MATERIAL BAGKFILL ��^-� _ I/2'x 3/8'PvG SG4IEDULE 40 MALE ADAPTER(TYPJ TREE BUBBLER DETAIL -V2"TNREADED SIDE OUTLET PVC SGI-IEDULE 40 TEE(SXSXT) OR ELL(SXT�GONNEGTED TO IRR.LATER4L LII�E. KING BROS.GV-MF SERIES C41ECK VALVE(TXT) OI DIFFUSER BUG CAP� RAIN BIRD DBC-025 (I OF 2 SI-IOWN,6 POSSIBLE) O2 UNIVERSAL Ya"TUBIN6 STAKE� RAIN BIRD TS-025 (I OF 2 SI-10WN,6 POSSIBLE) OY4'DISTRIBUTION TUBING� RAIN BIRD XQ TUB�IG (LENGTN AS REQIARED) (I OF 2 SI-IOWN,6 POSSIBLE) OSl1BTERRANEAN EMITTER BOX� RAIN BIRD SEB 7XB O M BARBED OUTLETPXERI-BUG EMITTER� RAIN BIRD XBT-10-6 6 TOP OF MULGH � FINISI-I GRA�E O PVC SCH 80 NIPPLE q (LENGTH AS REOUIRED) PVC SCl-I 40 TEE OR ELL O PVC LATERAL PIPE N 3"MNWMUM DEPTH OF 3/a"WASNED 6RAVEL PIOTE� L RAN BRD XBT-XX-6 IS AVALABLE N TI-E FOLLOWNG MODELS� XBT-05-6 0.5 GPH XBT-10-6 LO GPH XBT-20-6 2.0 GPH MULTI-OUTLET XERI BUG OUTLET PVG SC�1 40 T�OR B-� pN$(',I-L a0 RK'a62 PVC LAT62AL PDE RAN BRD'EASY FfT CQI�RE$° J ADAPIS2 EASY FfT GOhVRES'" J COUGLIJC'7 RAN 8R0'(t.00FCOIP) LArD�'.�CAPE DRPLPE TUBrK' W w �� a N 5EE IRR.LEGEND��' � l.d EASY RT COMPRES`'-.�IOM COUPLNG RAN BRD'(�AOCFCOID) OF�SET Ef�TTiH2 Tl�eNfi g'FROM BULDNG COMPRESSION RU5�1 CAP OR CI.RBNGV�� 'RAN BRD'MDCF�CAP) 3 DRIP LINE IRRIGATION DETAIL 'ERA.4SM1Y���MD�SFC�J COl1PlJNG� EASY RT 3/4"MALE COfvIPRESSION ADAPTH2� - 'RAN BRD'(MDCF75M�T) � O EASY FfT V2'MALE COMPRESSION ADAPTER RAN 9K2d(IvIDCF50�vFT) PVC LATERAL LINE LA�SCAPE ORIPLt�E 7UBING � V2-INCI-I POLYETNYLE�PIPE 'l EASY FfT COMPRES° COWLNG� 'RAN BRD�(MD('•PCOID) EASY FIT 3/4'FB�AALE COP.PRES� ADAPT52� T2AN BRD'(b1DCF75FPT) OQ EASY FiT V2"FEMALE GOMPRESSION AOAPTER 'RAN BRD'(Iv1D('.F50FPT) PVC LATERAL LI�E 7 I DRIP COMPRESSION ADAPTERS DETAIL � PVC SCN 40 T�OR B1 i0P OF M1C41 EASY FiT COAGRE55�ON GOI�LN('s RAN BRd O.00FCOWI -: �:_ .. ��APE ,e oowr,srr� _ RPN 0RD'QDI65M> IB'ON GB�:Hd SPACIJG r-r�.a+GrznDE— WG SC4I n0 R�5H2 CVC 5pa 40 T�OR 61 TOG OF AIA.CH RCO R[�e�'S�ADTH2 R+5u c,rtr� Q�%i �couvir� - k i '', ,,-,u i�,!.-,;'--'�rd..,i��.fi..�..;�.�_ - I.i r �_i i i '.... '..'��: ?' .�!�i�„ � .!=-. !.-_:�?,ri' : ,_ - _ ��� � `TIBNC� �J �� �.-.� DRPLrE GVC SC4I 40 RF.�62 / TE DOWN STAKE J 18' CHJ62 A� PVC LATERAL Lt�E DRIP LINE IRRIGATION DETAIL - SECTION EASY RT CO�RESSION ELBOW 'RAIIV BRD'(MDCFEU EASY FIT COMPRESSION TEE 'RAIN BIRD'(MDCFTEE> LANpSCAPE DRIPLINE TUBING OR I/2-INGN POLYETNYLENE PIPE EASY FIT COMPRESSION COUPLING� 'RAIN BIRO'(�CFCOUP) RAINY BIRD C MDGFGApION FLUSH CAP� DRIP COMPRESSION ADAPTERS DETAIL ��'��=i:�—c.� 1 �����'����L ,�!���'�.��_'�.,�_ �:�"�. � ,_ , � �—�.� i.� y.. •.r , ....,.. ... REED ASSOCIATES IANDSCAPE ARCHITECNRE 4n sourH rnnF� sraEEr SUNNWALE, CALIFOFWIA 94088 sae.�si�eozo i�oe.�ei�eaxx F�x �.e:w...d..�i.mrc�,w�w,w MIXED-USE COMMERCIAL 10049 IMPERIAL AVE. CUPERTINO, CA ISSUE DATE REVISIONS 08.25.13 �����. � � PAUL JAY REED� a No.2002 y * D(P.9/30/13 * Sr P 9TF ��L\� OWNERSHIP AND USE OF DOCUMENTS AN Drawinqe.Specifcatione ond copiea Meroof fwniahetl by Reed Naxiuta Londscape Arc�itecWro arc anE aMX rertan ita prapwly.TT�y an to M ua�d ony riM rpp�ct to Ma Projxt md are not to be use0 on ony other projett. Submisebn or distribul'an to m��t official nqulatory n- quirsmenta ar Ior purposea' connection with the Proj�ct if rat lo M caMru�d o�publicotion in Graplion ol Read Amaiahe Londscepe McAftectun.�ommon bw copyriplit w other rrmrved riqhb. Approved PJR Drawn � Reviewed PJR Project No. 13.06 Scole --- Issue Date 02.15.13 LANDSCAPE CONSTRUCTION DETAILS L3 . 1 sn.et of LANDSCAPE SPECIFICATIONS IRRIGATION SPRINKLER SYSTEM AND LANDSCAPE PLANTING 1.0 GENERAL A. THE WORK INCLUDES LABOR,MATERIALS.AND EQUIPMENT REOUIREO TO COMPLETE WORK INDICATED IN DRAWINGS AND DESCRIBED IN SPECIFICATIONS. t. PERFORM WORK IN ACCORDANCE WITH BEST STANDARDS OF PRACTICE RELATING TO VARIOUS TRADES.AND UNDER CONTINUOUS SUPERVISION OF A COMPONENT FOREMAN CAPABLE OF INTERPRETING DRAWINGS AND SPECIFICATIONS. 6. PRIOR TO CONSTRUCTION.VER�FY THAT CONTRACT DOCUMENTS REFLECT LATEST REVISIONS. INCLUDING PLAN CHECK REQUIREMENTS. C APPLICABIE PROVISIONSSOFTUNIFORMGPMUMBING CODEMPUBL�ISHED 8�WES ERN PLUMBING OFFICIALS ASSOCIA710N,NATIONA�ELECTRICAL CODE,AND OTHER CODES PROPERLY GOVERNING TMESE ACTIVITIES AT THE LOCATION OF THE WORK. 1. VERIFY LOCATIONS OF EXISTING UTILITIES WHETHER OR NOT SHOWN IN DRAWWGS. ASSUME RESPONSIBILITY FOR THEIR PROTECTION. D. THE CONTRACT DOCUMENTS ARE NOT INTENDED TO CONFUCT WITH REQUIREMENTS OF GOVERNING ORDINANCES. WHEN DRAWINGS AND SPECIFICATIONS DESCRIBE MATERIALS, WORKMANSHIP,OR CONSTRUCTION OF BETTER QUALITY,HIGHER STANDARD.PROVISIONS OF DRAWINGS AND SPECIFICATIONS TAKE PRECEDENCE. E. OBTAIN AND PAY FOR PERMITS AND INSPECTIONS REQUIRED FOR THE WORK. F. BEFORE PROCEEDING WITH THE WORK,VERIFY DIMENSIONS AND QUANTITIES. IMMEDIATELY INFORM IANDSCAPE ARCHITECT OF DISCREPANCY BETWEEN DRAWINGS, SPECIFICATIONS,AND ACTUAL CONDITIONS. COMMENCE WORK IN AREAS OF DISCREPANCY ONLY AFiER RECEIVING INSTRUCTIONS FROM L4NOSCAPE ARCHITECT. G. DIMENSIONS INDICATED IN DRAWINGS ARE APPROXIMATE. PROVIDE OFFSETS,FITTINGS, SLEEVES,EfC.,REQUIRED TO COMPLEfE THE PROJECT. PERFORM SIMILAR OPERATIONS FOR LIKE CONDITIONS WITHOUT ADDITIONAL COST TO OWNER. 1.1 SUBSTITUTIONS A. FURNISH MATERIALS IN QUANTITIES,512E.AND MANUFACTURE INDICATED IN DRAWINGS AND SPECIFICATIONS. B. FOR A PERIOD OF 30 DAYS AFfER EXECUTION OF CONTRACT,LANDSCAPE ARCHITECT WI�L CONSIOER FORMAL REOUESTS FROM CONTRACTOR FOR SUBSTITUTION OF PRODUCTS IN PIACE OF THOSE SPECIFlED ONLY UNDER THESE CONDITIONS. 1. WHEN SPECIFIED PRODUCTS ARE NOT AVAILABLE THROUGH NO FAULT OF SUB-CONTRACTOR. z BEETO I OWNER'SABEST N ERESTS ENJTE�MS OF�TIM�W COSTT OR OTHER CONS DERATIIONS. C. SUBMIT A SEPARATE REOUEST FOR EACH SUBSTITUTION. PROVIDE COMPLETE DATA SUBSTANTIATING COMPLIANCE OF PROPOSED SUBSTITUTION,INCLUDING PRODUCT IDENTIFlCATION,MANUFACTURER'S NAME AND ADDRESS.MANUFACTURER'S LITERATURE.AND SAMPLES AS APPLICABLE. D. MANUFACTURER'S WARRANTIES WILL NOT RELIEVE SUB-CONTRACTOR OF HIS LIABILITY UNDER THE GUARANTEE.ONLY SUPPLEMENT THE GUARANTEE. 1.2 RECORD DRAWINGS A. FURNISH OWNER WITH A SET OF RECORD DRAWINGS(REPRODUCIBLE VELLUMS)OF IRRIGATION SPRINKLER SYSTEM AT CONCLUSION OF THE INSTALLAtION. 1. OBTAIN VELLUMS FROM IANDSCAPE ARCHITECT AT COST OF REPRODUCTION PLUS 25 PERCENT. 8. INDICATE IN RECORD DRAWINGS ALL CHANGES MADE TO IRRIGATION SYSTEM DESIGN. 1.3 EXTRA MATERIALS q. FURNISH OWNER WITH 2 EACH OF THE FOLLOWING MATERIALS FOR EACH NPE OF VALVE AND SPRINKLER HEAD INSTALLED IN THE SYSTEM: 1. VALVE KEYS. 2. SERVICE WRENCHES 3. QUICK COUPLER VALVE KEYS. 4. HOSE SWIVELS COMPATIBLE WITH QUICK COUPLER VA�VES. 5. KEYS TO OPEN AUTOMATIC CONTROL CABINET. 1 5 B. INSTALLATION 1. PRIOR TO INSTALLATION,LAYOUT AND STAKE PRESSURE SUPPLY LINES,LATERAL LINES,AND LOCATION OF SPRINKLER HEADS. OBTAIN APPROVAL LAYOUT FROM LANDSCAPE ARCHITECT. A. IF EOUIPMENT IS INCORRECTLY LOCATED WITHOUT APPROVAL,RELOCATE PER DIRECTIONS Of LANDSCAPE ARCHITECT WITHOUT ADDITIONAL COST TO OWNER. 2. CONNECT SPRINKLER IRRIGATION SYSTEM TO POINT OF CONNECTION(P.O.C.)INDICATED IN ORAWINGS. A. MAKE CONNECTIONS AT APPROXIMATE LOCATIONS SHOWN IN DRAWINGS. B. ASSUAIE RESPONSIBILITY FOR CHANGES CAUSED BY ACTUAL SITE CONDITIONS. C. TRENCHING&BACKFILLING 1. EXCAVATION INCLUDES REMOVAL OF WATER AND MA7ERIALS,OR OBSTRUCTIONS OF ANY NATURE THAT WOULD INTERFERE WITH THE WORK. 2. REMOVE FROM THE SITE EXCESS AND WASTE MATERIAL RESULTING FROM TRENCHING OPERATIONS. 3. DIG TRENCHES STRAIGHT AND SUPPORT PIPE CONTINUOUSLY ON BOTTOM OF DITCH. A. L4Y PIPE TO AN EVEN GRADE. FOLLOW LAYOUT FOR TRENCHING EXCAVATION INDICATED IN DRAWINGS AND AS NOTED. 4. COVERAGES A. PROVIDE MINIMUM COVER OF 18 INCHES FOR PRESSURE SUPPLY LINES. B. PROVIDE MINIMUM COVER OF 15 INCHES FOR ALL NON-PRESSURE LINES INOICATED IN DR4WINGS. C. PROVIDE MINIMUM COVER OF 24 INCHES OVER PIPE UNDER VEHICULAR WAYS. D. PROVIDE MINIMUM COVER OF 18 INCHES FOR CONTROL WIRING. E. PROVIDE 3 INCH SAND BACKFILL.ALL SIDES OF PVC PIPE,WHERE SOILS CONTAIN GREATER THAN SOR ROCKS OR OTHER MATERIAL 1/2 INCH OR LARGER IN DIAMEfER WITHIN NATIVE BACKFILL MATERIAL. D. COMPACTION 1. COMPACT BACKFILL FOR TRENCHING TO A DRY DENSITY EQUAL TO ADJACENT UNDISTURBED SOIL IN PLANTING AREAS AND TO 909:IN PAVED AREAS. 2. CONFORM TO ADJACENT GRADES WITHOUT DIPS,SUNKEN AREAS,HUMPS,OR OTHER IRREGULARITIES. 3. PLACE INITIAI BACKFILL ON ALL LINES OF A FINE GRANULAR MATERIAL. 4. FOREIGN MATTER LARGER THAN 1/2 INCH IN SIZE WILL NOT BE PERMITTED. 5. IF SEffLEMENT OCCURS ANO ADJUSTMENTS IN PIPE,VALVES,SPRINKLER HEADS,LAWN OR PLANTING,OR OTHER CONSTRUCTION ARE NECESSARY,MAKE REQUIRED ADJUSTMENTS WITHOUT ADDITIONAL COST TO OWNER. E. HANDLING OF PIPE 1. INSTALL WC PIPE ALLOWING A SMALL AMOUNT OF EXCESS LENGTH IN THE LINE TO COMPENSATE FOR CONTRACTION OR EXPANSION OF THE PIPE. A. ACCOMPUSH EXCESS LENGTH 8Y"SNAKING"THE LINE IN THE TRENCH DURING TIME OF INSTALLATION. 2 US NDG APP OVEDEMEBTHODS,4NDTT00 5.A EXERCISES�A ES TO RKEVEN�T D MAGE�TO MATERIALS OR EOUIPMENT. A. KEEP INTERtOR OF PIPES,FITTINGS,AND ACCESSORIES CLEAN AT ALL TIMES. CLOSE OPENINGS IN PIPING RUNS AT THE END OF WORK EACH DAY TO PREVENT ENTRY OF FOREIGN MATERIALS. B. BENDING OF GALVANIZED STEEL PIPE WILL NOT BE PERMITTED. 3. PERFORM JOINTING BY COMPETENT TRAOESMEN SPECIALLY TR4INED IN THE lYPE OF WORK REOUIRED,USING TOOLS AND EOUIPMENT RECOMMENDED BY THE MANUFACTURERS OF THE PIPE,FITTINGS,OR EOUIPMENT. A. TAKE EVERY PRECAUTION TO SECURE A PERMANENT,WATER-TIGHT JOINT BEfWEEN EACH LENGn-1 OF PIPE. B. JOINTING PROCEDURES AND METHODS ADOPTED BY CONTRACTOR SHALL BE IN STRICT ACCORDANCE WITH RECOMMENDATIONS OF MANUFACTURER OF JOINTING MATERIAL USED. 1.4 WARRANTY A. FURNISH OWNER WITH GUARANTEE THAT IRRIGATION SPRINKLER SYSTEM IS FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP,AND THE WORK HAS BEEN COMPlETEO IN ACCORDANCE WITH DRAWINGS AND SPECIFICATIONS,OROINARY WEAR AND TEAR,UNUSUAL ABUSE.OR NEGLECT ACCEPTED. B. PROVIDE GUARANTEE FOR REPAIR OR REPLACEMENT OF DEFECTS IN MATERIAL OR WORKMANSHIP,SETTLING OF&4CKFILLED TRENCHES,AND TO REPAIR OR REPLACE DAMAGE RESULTING FROM THE REPAIRS OR REPLACEMENTS OF DEFECTS WITHOUT ADDITIONAL COST TO OWNER. C. MAKE REPAIRS OR REPLACEMENTS,INCLUDING COMPLETE RESTORATION OF DAMAGED PLANTING.PAVING,OR OTHER IMPROVEMENTS OF ANY KIND,WITHIN A REASONABLE TIME AS DETERMINED BY OWNER,AFTER RECEIPT OF WRITTEN NOTICE. D. IN THE EVENT OF FAILURE BY CONTRACTOR TO MAKE REPAIRS OR REPLACEMENTS WITHIN A TEN DAYS AFTER RECEIPT OF WRITTEN NOTICE,REPAIRS OR REPLACEMENTS WILL BE MADE BY OTHERS AT THE EXPENSE OF SUB-CONTRACTOR. E. WARRANTY PERI00 FOR IRRIGATION SPRINKLER SYSTEM, t YEAR FROM DATE OF ACCEPTANCE BY OWNER. 1.5 LANDSCAPE MAINTENANCE AND GUARANTEE A. PROVIDE MAINTENANCE FOR PLANTING AND IRRIGATION FOR 60 CALENDAR DAYS AFfER STAGE ACCEPTANCE. 1. WORK INCLUDES,BUT IS NOT LIMITED T0,WATERING.WEEDING,MOWING.FERTILIZING, CULTIVATING,SPRAYING,CUTfING,AND PRUNING NECESSARY TO KEEP PLANTS IN A HEALTHY GROWING CONDITION,AND TO KEEP PLANTED AREAS NEAT AND ATTRACTIVE IN APPEARANCE THROUGHOUT MAINTENANCE PERIOD. 2. IMMEDIATELY REPLACE DAMAGED,UNHEALTHY,OR DEAD TREES,SHRUBS,AND GROUND COVERS WITH SIZE AND KIND INOICATED IN DRAWINGS. 3 OFI4R OUNDS ERMI,�OOONSQUAREEFEET UNIFORMLYROVERDALDL PLANTNG�AREp,SHE RATE 4. UPON COMPLETION OF INITIAL 60 DAY MAINTENANCE PERIOD.NOTIFY LANDSCAPE ARCHITECT 48 HOURS PRIOR TO DATE OF INITIAL INSPECTION. B. GUARANTEE THAT PLANTS AND PLANTING AREAS ARE IN HEALTHY,THRIVING CONDITION FOR AN ADOITIONAL 60 DAYS AFTER INITIA�ACCEPTANCE OF PROJECT BY LANDSCAPE ARCHITECT. 1. FlNA�ACCEPTANCE MAY BE GRANTED AT THIS TIME AS DETERMINEO BY LANDSCAPE ARCHITECT. 2.0 PRODUCTS 2.1 IRRIGATION SPRINKLER MATERIALS A. PVC PLASTIC PIPE AND FITTINGS 1. MAIN LINE(PRESSURE)PIPING.TYPE 1120-1220 SCHEDULE 40,NSF APPROVED. LASCO.JOHNS MANVILLE,OR APPROVED EOUAL. A. MAIN LINE PVC PIPE FITTINGS.TYPE 1-11 SCHEDULE 40,NSF APPROVED. 2. LATERAL(NON-PRESSURE)LINE PIPING,TYPE 1120-1220 SCHEDULE 40.CLP,SS 200,NSF APPROVED.LASCO,JOHNS MANVILLE,OR APPROVED EOUAL. A. LATERAL PVC PIPE FITTINGS,TYPE 1-11 SCHEDUIE 40,NSF APPROVED, LASCO,SLOANS,OR APPROVED EQUAL. 3. SOLVENT,lYPE APPROVED BY MANUFACTURER OF PIPE AND FITTINGS. USE SCHEDULE 80 PVC THREADED NIPPLES IN RISER ASSEMBUES. 4. USE ONLY PVC PLASTIC PIPE FREE FROM BUSTERS,INTERNAL STRIATIONS,DENTS, WRINKLES,CRACKS,HOLES,FOREIGN MATERIALS,SMOOTH INTERIOR WALL WITH A GL455- LIKE APPEARANCE. A. CONTINUOUSLY AND PERMANENTLY MARK EACH PIPE WITH MANUFACTURER'S NAME,KIND OF PIPE,MATERIAL,SIZE SCHEDULE OR 1YPE,AND MANUFACTURER'S QUALITY CONTROL IDENTIFICATION. B. GALVANI2ED PIPE AND FITTINGS 1. WHERE INDICATED IN DRAWINGS,USE ASA SCHEDULE 40 MILD STEEL SCREWED PIPE.GALVANIZED,WITH MEDIUM GALVANIZED SCREWEO BEADED MALLEABLE IRON FITfINGS. A. GALVANIZED COUPLINGS MAY BE MERCHANT COUPLING. 2 6 C. CUT P�PE CUT STRAIGHT AND TRUE. D. AFTER CUTTING,REAM OUT ENDS TO THE FULL INSIDE DIAMEfER OF THE PIPE. E. IN CHANGWG PIPE DEPTHS,USE 450 ELBOWS. F. SPRINKLER HEADS 1. INSTALL TURF HEADS,WHERE ADJACENT TO FIXED OBJECTS SUCH AS HEADERBOARDS, CURBS,OR MOWING STRIPS,SO POWERED EDGING TOOLS CAN PASS BEfWEEN TURF HEAD AND FIXED OBJECT WITHOUT DIFFICULTY. 2. LOCATE SHRUB HEADS MINIMUM 12 INCHES FROM BACK OF CURBS AND EDGE OF WALKWAYS WHEN SHRUB HEAD IS MOUNTED ABOVE GRADE ON A RISER. G. CONTROL VALVES 1. INSTALL E�ECTRIC,NORMALLY CLOSED ANGLE CONTROL VALVES AS INDICATED IN DRAWINGS AND AS SPECIFIED BY MANUFACTURER. 2 REMOVAB�E COVERRTIFLUSH�WITH FINISHED GRADEM WHEREVER POSSIBLE EINS�AL�I IN A SHRUB AREA. H. ELECTRICAL WORK 1. PERFORM ELECTRICAL WORK IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE,THE STATE OF CA�IFORNIA ELECTRICAL SAFETY ORDERS,OTHER APPLICABLE STA7E AND LOCA� CODES AND REGULATIONS. 2. ASSUME RESPONSIBILIT'FOR 7HE COORDINATION OF ALL ELECTRICAL SERVICE CONNECTIONS TO THE CONTROLLER. I. FIELD QUALITY CONTROL 1. FLUSH PIPES BY REMOVING HEADS AND OPERATING THE SYSTEM AT FUII PRESSURE UNTIL ALL RUST.SCALE.SAND,ETC.,IS REMOVED. A. ONERT FLUSHING WATER TO PREVENT PONDING OR SOIL EROSION. 2. TEST PIPING UNDER FULL PRESSURE.WITH RISERS CAPPED FOR A PERIOD OF TWO HOURS. 3. INSPECT PIPE FOR LEAKS. A. CORRECT ANY LEAKAGE DISCOVERED DURING TESTS. 4. REPEAT TESTS UNTIL SATISFACTORY. 5. TEST SPRINKLER HEADS: A. TO DETERMINE THAT THEY FUNCTION ACCORDING TO MANUFACTURER'S DATA,AND B. TO DETERMINE THAT THE INSTALlATION WILL PROVIDE OESIGN COVERAGE. 6. ALLOW OR CAUSE WORK TO BE COVERED UP OR ENCLOSED ONLY AFfER IT HAS BEEN INSPECTED,TESTED,AND APPROVED BY LANDSCAPE ARCHITECT. A. SHOULD ANY WORK BE CLOSED OR COVERED UP BEFORE INSPECTION AND TESTS ARE SATISFACTORILY COMPLETED,UNCOVER THE WORK,AND AFfER IT HAS BEEN INSPECTED,TESTED,AND APPROVED,MAKE ALL REPAIRS WITH MA7ERIALS AS MAY BE NECESSARY TO RESTORE DISTURBED WORK TO ITS ORIGINAL AND PROPER CONDITION WITHOUT ADDITIONAL COST TO OWNER. 3.2 LANDSCAPE PLANTING PROCEDURES A. CLEARING&GRUBBING 1. PRESERVE EXISTING TREES IN AN UNDISTURBED CONDITION. 2. ROUGH GRADE FARTHEN MOUNDS TO CONTOURS INDICATED IN DRAWINGS. 3. CONSTRUCT MOUNDS WITH ENOUGH EXCESS MATERIAL TO ALLOW FOR FUTURE SETTLEMENT. A. FINAL LOCATION OF MOUNDS SHALL NOT CONFLICT WITH EXISTING UTIUTIES,UTILITY BOXES,VALVE BOXES,EfC. 4. NO COMPACTION WILL BE ALLOWED,EXCEPT FOR NORMAL GRADING AND SHAPING OPERATIONS. 5. UPON COMPLETION OF GRADING OPERATIONS,SPREAD EXCESS MATERIAL IN AREAS DIRECTED BY LANDSCAPE ARCHITECT. B. SOIL CONDITIONS 1. CULTIVATE PLANTED AREAS TO A UGHT AND FRU+BLE CONSISTENCY. UNIFORMLY TILL THE C. CONTROL WIRE 1. DIRECT BURIAL REMOTE CONTROL WIRES,U.L APPROVED TYPE U.F.MINIMUM OF 4/64 INCH VINYL INSULATION. CONSULT VALVE MANUFACTURER'S CURRENT WIRE SIZING C}iART FOR REOUIRED WIRE SIZES. 2. COMMON RETURN WIRE=WHITE.PILOT WIRE=RED.ORANGE.OR BLACK. 3. MAKE SPLICES WITH"SCOTCH lOK"N0.3577 CONNECTOR SEALING PACKS.OR nPPROVED EQUAL. D. SPRINKLER HEADS,REMOTE CONTROL VALVES,AUTOMATIC CONTROLLER,QUICK COUPLER 1. TYPE.SIZE,AND LOCATION INDICATED IN DRAWINGS. 2. LOCATE REMOTE CONTROL VALVES AND QUICK COUPLERS A MAXIMUM OF 12 INCHES FROM CURB.WALK,OR HEADERBOARD. E. BACKFLOW PREVENTION t. BACKFLOW PREVENTERS AS INDICATED IN DRAWINGS OR AS APPROVED BY LOCAL GOVERNING BODY. 2. DO NOT LOCATE IN LAWN AREAS. 3. SCREEN UNIT WITH PLANT MATERIAL SHOWN ON PLANTING PLAN IN LOCATION OF BACKFLOW PR�ENTER OR ELSEWHERE ON SITE WHEN DIRECTED BY IANDSCAPE ARCHITECT. 4. AVOID USING PVC PIPING IN BACKFLOW PREVENTER ASSEMBUES. F. VALVE BOXES 1. CONTROL VALVE BOXES,AMETEK N0. 10-70-00 WITH GREEN COVER LID N0. 10- 173-004,OR EQUAL. PROVIDE EXTENSIONS IF REOUIRED. 2.2 LANDSCAPE PLANTING MATERIALS A. SOIL 1. EXISTING SURFACE SOIL,UNLESS OTHERWISE INDICATED IN DRAWINGS,fREE FROM SUBSOIL,REFUSE,ROOTS,HEAW OR STIFF CLAY,ROCKS,STICKS,BRUSH OR OTHER DELETERIOUS MATERIALS. 2. NATIVE SOIL,MATERIAL EXCAVATED FROM PLANTING HOLES,FREE FROM ROCK OVER 1/2 INCH IN DIAMEfER. 3. IMPORTED SOIL.IF REOUIRED.SANDY LOAM TEXTURE. A. SUBMIT SOIL SAMPLES ANO ANALYSIS OF IMPORTED 501�TO LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO DELIVERY TO PROJECT SITE. B REASON,ELECTASOIL M TIERIAL ROMTAADF ERENI�SOURCELANDERES�BMIT�p ANY LANDSCAPE ARCHITECT FOR APPROVAL WITHOUT ADDITIONAL COST TO OWNER. B. FERTILIZERS AND SOI�AMENDMENTS 1. COMMERCIAL GRApE FERTIL2ER5 ANO SOIL AMENDMENTS,UNIFORM IN COMPOSITION, DRY AND FREE-FLOWING,DELIVERED TO SITE IN ORIGINAL,UNOPENED CONTAINERS, EACH BEARING THE MANUFACTURER'S GUARANTEED ANALYSIS. 2. MATERIAL WHICH BECOMES CAKED OR OTHERWISE DAMAGED,MAKING IT UNSUITABLE FOR USE,WILL BE REJECTED. A. FERTILIZER'A': FERTI TURF AND PEIANTING AR�EASESHALL BEPPELLETED 7YPE HAVING A N6-P20-K20 FORMULA. B. FERTILIZER'B': FERTILIZER TO BE APPUED TO LAWN AREAS PRIOR TO SEEDING OR SODDING SHALL BE PELLEfED TYPE HAVING N6-P2-KO(WITH 1%IRON). C. FERTILIZER'C': FERTIBEEA PLANT TAB�WTHRFO MULA N20 P ONTKSITSUCH AS AGRIFORM. D. FERTILIZER'D': FERTILIZER TO BE APPLIED TO LAWN AREAS AFTER TURF IS ESTABLISHED AND AROUND INSTALLED CONTAINER PlANTS DURING THE MAINTENANCE PERIOD SHALL BE PELLETED TYPE COMBINATION CHEMICAL ORGANIC FORMULA N15-P2-K6. E. SOIL AMENDMENT: RECYCLED COMPOST MATERIAI., 3 ? FOLLOWING MATERIAL.PER 1,000 SOUARE FEET,INTO THE TOP 6 INCHES OF SOIL,USING A ROTOTILLER OR SIMILAR MACHINE.THEN THOROUGHLY WATER. 6 CU.YDS. - RECYCLED COMPOST MATERIAL(SOIL AMENDMENT) 25 LBS. - FERTILIZER A' 15 LBS. - SOIL SULPHER 2. CULTIVATE EXISTING PLANTING AREAS WITH HAND TOOLS. 3. PREPARED SOIL MIX FOR BACKFILL IN PITS FOR TREES.VINES,AND SHRUBS,CONSISTING OF THE FOLLOWING: 1/3 YD. - RECYCLED COMPOST MATERIAL(SOIL AMENDMENT) 2/3 YD. - NATIVE SOIL 1 LB. - IRON SULPHATE AND FERTILIZER'C'AS FOLLOWS 1 GAL: 1-TAB 5 GAL: 2-TABS 15 GAL: 4-TABS 6-8 TABS FOR BOXED MATERIAL 4. CONDUCT SOIL PREPARATION AND PLANTING OPERATIONS ONLY UNDER FAVORABLE WEATHER CONDITIONS. SOIL SHALL NOT BE WORKED WHEN EXCESSIVELY DRY OR WET. A. LANDSCAPE ARCHITECT RESERVES THE RIGHT TO STOP WORK TAKING PLACE DURING A PERIOD WHEN CONDITIONS ARE CONSIDERED DETRIMENTAL TO SOIL STRUCTURE OR PLANT GROWTH. C. PLANTING TREES,SHRUBS,&VINES 1. DIG PITS FOR PLANTS SOUARE PER DEfAIL IN DRAWINGS. A. LEVEL SIZE OF PITS SHALL BE 2 TIMES DIAMEfER OF ROOT&411,AND ONE-HALF AGAIN AS DEEP AS THE DEPTH Of ROOT BALL. B. SOIL AT SIDES AND BOTTOMS SHALL BE LOOSENED BY SCARIFYING TO ENSURE R00T PENEfRATION. AVOID SMOOTH CIRCULAR SIDES. 2. &4CKFILL PITS WITH"PREPARED SOIL"TO THE BOTTOM OF 7HE R00T BAL�. THEN SET THE PLANT IN AN UPRIGHT POSITION IN CENTER OF HOLE. BACKFlLL SPACE AROUND IT WITH PLANTING MIX. A. WHEN THE BACKFILL AROUND THE PLANT IS APPROXIMATELY 1W0-THIRDS COMPLEfED.TMOROUGHLY WATER. BACKFILL COMPLEfE TO THE GRADE OF THE SURROUNDING AREA. B. THE CROWN OF THE PLANT SHALL BE 1-1/2 INCHES ABOVE(MINIMUM)FINISHED GRADE. 3. PREPARE A SOIL RING AT LEAST 3 INCHES HIGH AND AS WIDE AS ROOT BALL AROUND EACH PLANT(NOT IN A TURF AREA)TO REfAIN WATER. A. WATER THOROUGHLY TO ELIMINATE AIR POCKETS. B. REMOVE TURF IN A 24 INCH DIAMETER RING AROUND EACH TREE BASE IN TURF AREAS. D. PLANTING GROUND COVERS 1. PLANTING SHALL TAKE PLACE IN THE EXISTING PREPARED M015T AND FRIABLE SOIL, NEVER DRY OR WET AND SOGGY. A. THE M015T CONDITION SHALL EXTEND TO THE FULI DEPTH OF CULTIVATION. 2. SPACE GROUND COVER PLANTS AS INDICATED IN DRAWINGS AND IN THE PLANT UST. 3. PLANT IN EVENLY SPACED ROWS WITH STAGGERED TRIANGULAR SPACING AND AROUND SHRUBS AND TREES TO WITHIN ONE FOOT. 4. NO GROUND COVER SHALL BE PLANTED LESS THAN ONE-HALF OF 7HE SPECIFIED SPACING fROM ANY CURB OR WALKWAY. E. PLANTING TURF GRASS 1. AFfER ALL SOIL AMENDMENT AND FERTILRERS HAVE BEEN APPI.IED AND CULTIVATED INTO SOIL,FINE GRADE ALL AREAS. 2. REMOVE RIDGES AND DEPRESSIONS. AREAS SHALL BE SMOOTH,CONTINUOUS,FIRM PLANES THAT ENSURE PROPER SURFACE DRAINAGE. 3. REIAOVE ROCKS,SOIL LUMPS,AND DELEfERI0U5 MATERIALS LARGER THAN 1 INCH,RAKE AND COMPACT AREAS WITH A 200 POUND ROLLER. 4. AVOID ADDRIONAL COMPACTION OF THE SOILS AFfER TREATMENT. DO NOT PERM�T VEHICULAR OR EQUIPMENT TRAFFIC OVER AREAS. F. IRON SULFATE: STANDARD COMMERCIAL BRANO. C. WOOO CHIP MULCH 1. ALL PLANTED AREAS,EXCEPT TURF,SHALL RECEIVE A TOP DRESSING OF MULCH TON3/4"INOIAMETERCY SHREDDED B RK�IDS UHNACCEPTABLECHIPS,MEDIAN GRIND 3/8 TO D. PLANT MATERIAL 1. CONFORM PLANT MATERIAL,INDICATED IN DRAWINGS BY THE LISTED NAMES.TO OLLOW R HE ESTABL�ED CUSTOM�S OFTIO E NURSERY TRADEAMES NOT INCLUDED, 2. ALL PLANTS SHALL BE TRUE TO NAME. TAG ONE OF EACH BUNDLE OR LOT WITH THE RECOMMENDEDEBYFAMERIC NNASSOCI TONOOF NURSERYMEN.DARDS OF PRACTICE 3. ALL PLANT MATERIALS SHALL MEEf THE SPEGFICATIONS OF FEDERAL,STATE,AND COUNTY LAWS,REOUIRING INSPECTION FOR PLANT DISEASES AND INSECT INFESTATIONS. 4. PLANTS SHALL BE SYMMEfRICAL,TYPICAL FOR VARIETY AND SPECIES,SOUND,HEALTHY, VIGOROUS,FREE FROM PLANT DISEASES,INSECT PE5T5.OR OTHER EGGS,WITH HEALTHY,NORMAL R00T SY57EM5,WELL FILLING THEIR CONTAINERS,BUT NOT TO THE POINT OF BEING R00T BOUND. 5. USE ONLY PLANT MATERIALS THAT ARE FIRST CLASS REPRESENTATNE OF THE SPECIES AND CULTNARS SPECIFIED AND THAT CONFORM TO ALL STATE AND LOCAL IAWS GOVERNING THE SALE.TRANSPORTATION,AND INSPECTION OF PL4NT MATERIALS. 6. PROVIDE ONLY PLANTS WITH STRAIGHT,SINGLE TRUNKS,UNLESS OTHERWISE INDICATED IN DRAWINGS. 7. THOSE SPECIFIED TO BE MULTI-TRUNK SHALL HAVE AT LEAST THREE MAIN LEADERS FROM THE&4SE. 8. PIANTS THAT HAVE ENCIRCLING ROOTS,NOT ROOT BOUND,SHALL HAVE ROOT&4LLS UGHTLY SLASHED ON A MINIMUM OF 3 SIDES TO STOP ENCIRCLING R00T GROWf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fION OF PRELIMINARY FINISH GRADING ANO IRRIGA710N SPRINKLER SYSTEM. 2. INSPECTION OF PLANTS PRIOR TO LAYOUT. 3. LAYOUT INSPECTION OF SPOTTED PLANTS. 4. INITIAL WSPECTION UPON COMPLEfION OF PLANTING AND TREE STAKING.PRIOR TO COMMENCEMENT OF MAINTENANCE PER100. 5. FINAL INSPEC710N AT CONCLUSION OF ADDITIONAL 60 DAY LANDSCAPE MAINTENANCE PERIOD. B. USTED INSPECTIONS WILL BE MADE BY IANDSCAPE ARCHITECT OR AN AUTHORIZED REPRESENTATNE. 1. REQUEST INSPECTION BY LANDSCAPE ARCHITECT AT LEAST 48 HOURS IN ADVANCE OF TIME INSPECTION IS REOUIRED. 3.0 EXECUTION 3.i IRRIGATION SPRINKLER SYSTEM A. PREPARATION 1. COORDINATE INSTALL4TION OF SPRINKLER MATERIALS,INCLUDING PIPE,TO ELIMINATE INTERFERENCE WITH,OR DIFFICULTf IN PLANTING SHRUBS,TREES,GROUND COVER, CON OURS AND ES�ABUSHEDITGRADESDCHANGEDCDURNGCCOURSEROFr�HE WORKRIGINAL 4 8 A. IN THE EVENT OF SUCH COMPACTION,CONTRACTOR WILL BE REQUIRED TO RECULTIVATE COMPACTED AREAS. 5. SODDING: RAKE AREAS TO FINISH GRADE ELEVATION TO 1 INCH LOWER THAN ADJACENT PAVING TO ACCOMMODATE SOD THICKNESS. A. SPREAD 20 POUNDS PER 1,000 SOUARE FEET OF FERTILIZER'B'ON SOIL SURFACES PRIOR TO SODDING. THEN NEATLY INSTALL SOD SU+BS. 8. STAGGER END JOINTS,TIGHTLY JOINTED WITH NO VISIBLE SPACES. C. LIGHTLY WATER AND ROLL ENTIRE AREAS. THEN HEAVI�Y WATER TO ASSURE WATER PENETRATION OF AT LEAST A DEPTH OF 8 INCHES. 6. SEEDING: APPLY FERTILIZER'B'TO FINISH GRADED SURFACES AT THE RATE OF 4 POUNDS PER 1,000 S�UARE FEET. A. USE ONLY SEED THAT IS WEED FREE.FRESH,RECLEANED.GRADE A,NEW CROP CONSISTING OF THE PERCENTAGE OF MIX AS DESCRIBED IN DRAWINGS. B. LABEL SEED IN ACCORDANCE WITH THE U.S.DEPARTMENT OF AGRICULTURE RULES AND REGULATIONS UNDER THE FEDERAI SEED ACT PRESENTLY IN EFFECT ANO SHALL BE DELNERED TO PROJECT SITE IN BAGS BEARING DEALER'S LABEL AND GUARANTEED ANALYSIS. C. SOW SEED IN 2 DIRECTIONS AT A TOTA�COMBINED RATE OF 10 POUNDS PER 1.000 SQUARE FEET. D. SOW SEED BY EXPERIENCED PERSONNEL AT A TIME WHF.Jt CtfiTL"E��.OR�°NfT^YVIN,p.�lSp BLOWING. . , ,- � ..?"�i� E. LIGHTLY RAKE INTO TOP 1/8 INCH OF SOIL. F. DO NOT MOW UNTI�TURF IS 2-1/2 INCHES HIGH,AND FOR INITIAL MOWING DO NOT MOW LOWER THAN 1-1/2 INCHES. REMOVE ALL CLIPPINGS. 7. FERTILIZING DURING MAINTENANCE: APPLY FERTILIZER'D',3G i AFfER PLANTING,AT THE RATE OF 5 POUNDS PER 1,000 SQUARE Fl A. REPEAT EVERY 30 DAYS THROUGH MAINTENANCE. F. WEED CONTROL,PEST CONTROL,&MULCHING 1. WEED CONTROL MATERIAL SHALL BE A PRE-EMERGENT HERBICIOE.TRIFLUI��.�i�R��`N) OR DIPHENAMID(DYMID OR ENIDE)OR APPROVED EQUAL,APPLIEd��4yY'rlacvit�' AREAS.DON'T APpLY TO TURF DEVELOPED AREAS. 2. CONSIDER IT PART OF CONTRACTOR'S WORK TO CONTRO�ON-SITE OR NE4RBY PESTS THAT ARE DISTURBING THE CONDITION OF LANDSCAPE IMPROVEMENTS. / 1 3. CONTROL OF PESTS INCLUDES.BUT IS NOT LIMITED TO RODENTS,R4881TS,INSECTS. Il DEER,ETC. ` 4. REPAIR DAMAGE THAT OCCURS TO THE ORIGINA�CONDITION OF IMPROVEMENTS, INCLUDING REPLACEMENT OF PLANT MATERIAL WHEN REQUIRED.WITHOUT ADDITIONAL COST TO OWNER. 5. SPREAD&4RK CHIP MULCH EVENLY OVER ENTIRE PLANTED AREA,EXCEPT TURF DEVELOPED AREAS,TO A MINIMUM DEPTH OF 2". G. PRELIMINARY INSPECTION AND STAGE ACCEPTANCE 1. UPON COMPLETION OF PLANTING WORK,NOTIFY LANDSCAPE ARCHITECT THAT PROJECT IS READY FOR INSPECTION. 2. UPON INSPECTION,IF lANDSCAPE ARCHITECT FINDS ENTIRE PROJECT COMPLETE AND IN COMPLIANCE WITH DRAWINGS AND SPECIFICATIONS,STAGE ACCEPTANCE WILL BE GRANTED. .S. IF ASPECTS OF PROJECT ARE INCOMPLETE OR IMPROPERLY INSTALLED,CONTRACTOR WILL BE NOTIFIED AND HAVE 5 WORKING DAYS IN WHICH TO CORRECT OR COMPLEfE THE WORK. 4. STAGE ACCEPTANCE WILL BE GIVEN ONLY WHEN ALL WORK IS CORRECT AND COMPLEfE. 5. THE STAGE ACCEPTANCE BY LANDSCAPE ARCHITECT OF LANDSCAPE PROJECT WILL ESTABLISH THE BEGINNING OF PLANT MAINTENANCE PERIOD. 3.3 CLEANING A. UPON COMPLETION OF WORK,REMOVE EXCESS MATERIALS.RUBBISH,DEBRIS,AND SUB-CONTRACTOR'S CONSTRUCTION AND INSTALL4TION EQUIPMENT FROM THE PREMISES. 8. FINAL INSPECTION OF THE WORK WiLL BE MADE BY LANDSCAPE ARCHITECT IN THE PRESENCE OF THE SUB-CONTRACTOR WHEN WORK IS COMPLEfED. NOTIFICATION SHALL BE MADE BY THE CONTRACTOR 48 HOURS IN ADVANCE OF SUCH INSPECTION. REED ASSOCIATES LANDSCAPE ARCHITECNRE 477 SOl1TH TAAFFE STREET SUNNWALE.CALIFOFB�IIA 94086 �ae.�ei�sozo i�oe.sei-sosz F�x w�b:w.w.Ntntl i�mYl:p�ulO�lu+r MIXED-USE COMMERCIAL 10049 IMPERIAL AVE. CUPERTINO, CA ISSUE DATE REVISIONS 08.25.13 ����� � � �PAUL JAY REED� n No.2002 � * EXP.9/30/13 * Sf �aP 9TF ��y: ��`\F" OWNERSHIP AND USE OF DOCUMENTS /JI Drorirqs.SpacifKaliom and copee thereot fumiMed Dy ReeE Map�iotes Lordscape Ncliileclve aro ana ahox rartaF ih P�Wrty.71�'w�to W uaW ony with nsD�ct lo Mis Projxt anE ore not to Da uaed on any othsr projxt. Subminion or d'nlribution to m��t official rogubtory ra- Quirements or for purposee'n connxtion with t�e ProjM is rot to M caMrwE ae D�blkatiai in d�roqation or aeed Mwciota La�dxaps Mcnilachiro.common a�copyriqhl or otAer reaerved riqhb. Approved PJR Drawn NG Reviewed PJR Project No. 13.06 Scale --- Issue Date 02.15.13 �� ���~��� �' -�C13 -�e� �- �`� _.,..,,,._-.-..,P ..,..,....._,.;,��.�:._......:,.,,,-,�.��»�.�,��-: ,. s _ '?J�,t �/�-13 .......... . . ... ...._..�a�.:...,... LANDSCAPE SPECIFICATION PLAN L4 . 0 sneet of � I , ,� N ��1' � I ,�' � 'p�3 � ��� ' P� � o `�5 I � � I 0 ��. °a LOADING ZONE I 0 I � � 20 10 0 10 Z� �' PROPOSED PARKING I SCALE: 1"=10' o CONFIGURATION I � o TOP�I T.C. t ND .C. � WHEEL 5 � TYPICAL I � 4' X 4' TYPICAL � / / I . O� :� ,' 8s� L . . �� I ti� �� I - o � o 0 0 0 � ° o , .. � _T =-- –r-=- -— � >'� --- ___ ___-------- � �T �---- � 0 o f o 0 0 ° o ° j ° ° • �, 1 � !-� � ! O 1► �, i, � � o , i � • � 8.50' I � , � o' , 3r , ���.,,, �',,, �, '', I �'.,... -- — -- -- --I — -- �— �— -- � o• o — -- -- — — � — — — -- -- Rp,�NP�G� . ' ' 0 �N\N I >• oP I . I e. �• �� 22' PROPOSED 'o REMOVE EXISTING CURB • o � EGRESS/INGRESS ° TYPICAL °o • ° • v N N �v �EASEMENT N EXISTING ASPHALT � N 4.' • f PARKING LOT � ' (N) A1-6 / APN. 357-17-012 O (N) A1-6 CURB � � I •.., .:� CURB TYPICAL TYPICAL '' � - — — ' .'s � 8.50' —Q — — -t- — — — , — + � . % 9.00' I ADJACENT 3� � 3. �8.50'�1 o I �I I •'° BUILDING I I , � o� �� �T.C. 101.5 I � I � � 20.00' ; `O , � � • I I , � I` I li I - - I _ _ 1�, _ _ _ _I ,.�0� 3'— — T.C. 102.0 --�-5 — 00' PARKING� SWALE -�— o� �— � � 3.0 ' PAR G o I� GR=100.5 '2. 0' M� EASEMENT � ASE T � 'oo INV=98.0 ' 5.0 115.00' 5.0' � F.G. 101J / `/ T.C. 102.5 ' WALK I o . m -��—��� DRAINAGE � � F.G. 101.5 '�' � �� �' t� c=.> p ,y(J; 20' PROPOSED �7� 3.60' � � � • 1 � o� �'-' EGRESS�INGRESS ��� � ' � � r � � � EASEMENT �o. � I ' o a ptt � o GARAGE N �n PSPH "o u� ,°�e�_ r �� � 4" P BM �� N APN. 357-17-013 �� �- . . $' P' •v MAIN tn __�_� _`� _ __�I� . F.F. 101.75 ENTRANCE d , I� F.G. 101.5 HC ACCESS (N}�IM (E) s ., o--�—� � DETECTABLE H� O4 � •,, 5 � °O WARNING o o WALK SL SURFACE o e ACCESS (N)5.5. .0. ao ] ���' �..H CIASS�III 7.0 6 'N--, , LIMIT OF(N) (E) ��RLITIE�S PARKI�NG �/5 � . PAVING p0 • ! BLOCKS , ��.`ti' F.G. 101.2 7 I r ►•,' � o I � LANDING � (E) 3'HIGH ,Z• � , RETAINING WALL� _ _ _ � _ 5 •,.� . (E) 6' HIGH � (E) GARA(�E _� REMOVE(E) CONCRETE � � • •D v WOOD FENCE� � N � REMOVE _; }5% o DRIVEWAY. INSTALL(N) � � �> � � Q � � � � � PAVING BLOCKS� °� � � - - - L-� - - - - 115.00' GR=101.0 6" INV IN=97.1 (E) 8' HIGH 12"INV OUT=96.6 , WOOD FENCE 10' PROPOSED � � ADJACENT BUILDING INGRESS/EGRESS EASEMENT � ` I ( � APN. 357-17-014 WAY I ! � I ' BQRELOCATE 15" OAK I -- - - - - - - - - - - - - - - - - - - � �(E) OVERHEP�D UTILITIES BOTH SIDES IIIOF STREET I I ii � I i I i I � R � � PROJECT BENCHMARK= PK NAIL EL.=100100' (ASSUM�D) � QE) CONCRET�VALLEY GUTTER (N) ELECT�OLIER �CUPERTINO STD. 5-14 ,� (E) CONC.�CURB T GUTTER & ' SIDEWALK TO BE - REPLACED' � � ��r ,f i�.� , � I �r� � r w w i �� SDMH �,,, RIM=100.26' __N I '� ' €� �II � 6Q s � SD 4`F ,2.. S,y SD� � i DMH RIM=100.04' 12"INV IN=95.8 INV=94.5 i � NOTES• R�W � R/W U I �o.00� PARKING DRIVING LANE � 8.5' 26' � 16.00'--I 7.00' � � 47.00' � I ao.00' � � 5.00' 35.00' 2.00' 5.00' 1.00' ASPHALT SIDEWALK f— -� SAWCUT&MATCH � (E)CURB &GUTTER REMOVE � (N) A2-6 CURB &GUTTER I (N) 1-19 DETACHED SIDEWALK IMPERIAL SECTION NOT TO SCALE 1Q INSTALL 6" STORM DRAIN PIPE MIN. 1%SLOPE. 2O NEW CURB IN EXISTING PARKING LOT. SAWCUT ASPHALT 12" FROM NEW A1-6 CURB. PAVE I WITH 8" MIN DEPTH. 3O SEAL COAT EXISTING PARKING LOT WITH 2 COATS. RESTRIPE. I Q4 INSTALL 4" SANITARY LATERAL(GRAVITY) FROM CLEANOUT AT BUILDING TO CLEANOUT I AT PROPERTY LINE. CONTRACTOR TO VERIFY EXISTING SEWER LATERAL. Q5 EXTEND 1" WATER SERVICE. RELOCATE METER. O INSTALL 12° STORM DRAIN PIPE MIN. 1%SLOPE. � 7O REMOVE EXISTING WALL. I 80 RELOCATE 15" OAK. I90 SAWCUT EXISTING CURB, AND MATCH. � ABBREVIATIONS: y � (E� EXISTING ��-�-,��r�4---� � PROPOSED � ~� I �N� ,... ��x �,� �q—.,�c I.� ' � �/ AC ASPHALT CONCRETE � •.= �*� ,•:,� � ✓�,� � (��%�" ,...M,� __. ______...,. ABM AGGREGATE BASE "" I MATERIAL -'i� . I F.F. FINISH FLOOR ���� -/ ry (E)CURB & E.G. EXISTING GRADE ,,-_:.......�,. . _ �' SIDEWALK I __...,. F.G. FINISH GRADE -� H.6. HEADER BOARD a* �.. ,-., .. . •s:: � L/S ; s..���,.:i�:.s LANDSCAPING �.: t,,,,�� I ..: _�._.�..� , O.H. OVER HEAD UTILITY A��� " (E)UTILITY POLE &LIGHT I PAV PAVING T.C. TOP OF CURB GRADE $ PIPE SLOPE I I S.S.C.O. SANITARY SEWER CLEANOUT S.D.M.H. STORM DRAIN MANHOIE I WM WATER METER GR GRATE � INV INVERT � I LEGEND: PROPERTY LINE I � - — — — — - PROPOSED EASEMENT LINE I SL NEW SANITARY LATERAL SD NEW STORM DRAIN � — � )— SWALE � � DIRECTION OF SURFACE FLOW I � 18" X 18" INLET � ■ 6"NDS DRAIN � SPOT ELEVATION I ❑ ASPHALT CONCRETE PAVEMENT SHEET INDEX � � SHEET N0. DESCRIPTION I ' CONCRETE PAVEMENT SHEET 1 GRADING AND DRAINAGE PLAN SHEET 2 EROSION CONTROL PLAN I SHEET 3 EASEMENT PLAN PAVING STONES SHEET 4 DEMOlITION PLAN SHEET 5 OFF SITE IMPROVEMENT PLAN � SHEET 6 BEST MANAGEMENT PRACTICES i �\, REMOVE TREE l` REVISIONS � ,.. c � v'i+ � CZ m Mo C� tA o°c' .�� ���� CJ a w c • mU• rn o> $Nmw •C� �ivm� W �n�t/��o �%� J O C�7? � rn ���3 C co 0 3 �w � �3 Z�> m U � � 0 F,R D.�y�< No.21755 Z � L.L.� � � Q Q w L Z_ � O Q�/ � � LL — 0 J Q a � � Z w „ Q LL � � � � Z � � d- �.L.� � � O � C� r- U Date: AUG 2013 Scale: 1"=10' Drawn: CAD Job: LONG Sheet � of � Sheets ? � � �\I � (!.?mJ � Vd� `,I � � ���`W iii STRAW ROLLS MUST B£PUCEO ������ � ALONC SLOPE CONR7UR5 � � � T1CH7LC�UT�SHAL.L �I.\ `W w � � ♦ 1 f0'—?5'(3-8mJ � � \ i � � ` SPAC/NC DEPENOS ON SO/L TYPE AND �• SLOP£ST££PNESS S£D/M£NT, ORGNWC AlATTER, �AND Ab4TNE SEEOS ARE � � CAPTUR£D BEH�ND THE ROLLS. / - J=5"(75-125mmJ B'-f0'04L / � (200-250mm) L/VE STAKE M•� i, i� • .Y �i ��i �T �j ' �i � G 1"X 1"STAKE ��� (25 x 25mmJ � �\ �� NOT TO,SGILE . � NOTE.• 1. STR4W ROLL/NSTALL.4770N REOU/RES TH£ PLAC£AIE/VT AND SECUR£STAK/NG OF 7NE ROLL�N STRAW � A TRENCN, J'-5'(75-125inm)DEEP, DUC ON CONTOUR. RUNOf]r A/UST NOt BE ALLOWED TU RUN g u,votn oR aPOUNO�c. ROLLS O „�:�,� CITY Of CUPERTINO APPRO DA � � 8-18 STANDARO DETAI�S qTY ENGIN � ! �� �� � II II ' I � I I e"n+�cK,i 3'TC STi PROVIDE STP UNDER ROCK STABILIZED ENTRANCEWAY N.T.S. I I �10' PROPOSED INGRESS/EGRESS EASEMENT I I - - � I I � � � � .--.�. i `` � � � I �� ; J� _ �t �� � � W �. I� � SD� � SD\ � � I I NOTES: O INSTA�L STRAW ROLL WATTLE PER CITY STANDARD 8-18. LEGEND: PROPERTY LINE PROPOSED EASEMENT LINE W W— NEW WATER SERVICE Sl NEW SANITARY LATERAL SD NEW STORM DRAIN � � � � � STRAW ROLLS � DIRECTION OF SURFACE FLOW � 18" X 18"INLET • 6" NDS DRAIN SPOT ELEVATION ❑ ASPHALT CONCRETE PAVEMENT � CONCRETE PAVEMENT � REMOVE TREE j��-�t;1�- C! . n �b.�—�C1� "a� � �f � _ ..v.T r�__ _.__._. __.,..,..._� �_n..��,y.,...:,..�.:. . . q-i�-�3 .�, � N 20 10 0 10 20 SCALE: 1"=10' � REVISIONS � �, C ^ ���, � e � N �o m �� ' N CD U C� in0�Ol .�'p ���.� c �J mU�� '�rn g��w C c `°mr�m`-' � C7 v v C J O M Z � �J�� E _ � o p W � v 3 Z'> m U � 0 ,.�,�essip�,� �OGF'Ft�./y���� ��No.21755 Z� �lq �I V 1� A�< lF OF�AI�E� Qw � a � zz a. w � JQO O — J � Q Q z � U O w .. U � O � Z Z — � O � � � � �.1..� � � � � Q � w r- U Date: AUG 2013 Scale: 1"=10' Drawn: CAD Job: LONG Sheet � of � Sheets I I I I I I I �� I I I II I I I � � t I . , . , '��.. � . . . � . , I ... � . . " . I -.___— ,�. I � 0 � � � � ` 0 � � 0 I , , � ,. ----i- --�----- --- - -.- ---- T----- _� ____-,-_ � .�I 0 o . o� o 0 0 . o o , o �i o . o ��.. o , .. . ,,. ..,. ,.. ,,, ,... ,. i I � . .�.. I ,. , , , '., , ., ., � � ` ���. ����. . �, '', � .. �'�. �, . � ( I �. .°'• ��. , . . ,. �'�, �. I � . I � . '.,. ,,,,. ,' ',I ��,, '.,. �',. '', ', . o�� � , , . , .� , , �, , , .. " o ' ' --.. ..--- �- — �—� -- -- --_ __ __ _ -- — - — — — , � - — _ � . . I I �° , I !• � , �•� ' 22' PROPOSED I • • . I � EGRESS/INGRESS ° • v I V �EASEMENT . ; 'I ' � i �• .>` � �, .,� , � - i . � I _ . . � - -r - - - - � - -- -- - r-- -+- - - � -�- -� , I ' � i '', ' i � , , I , , ,�� i , ', ,, i I ' i ; I I i i - - - � - - - - _�- � r ' -� — — — .00' PARKING�— — �_ —�— �.,__.—_�- -�- � . � 3.0 ' PAR G �\/ ` � ,�ASE�T EASEMENT X I I �, � % �. �I I . i p - I I e� � i 'LJLd _,_ ; 20' PROPOSED � � ' EGRESS/INGRESS I_� ' . - � � EASEMENT � , �, ��°' I . . I r� e. ' LJ.J � ••• I �� - � -�0�- �I � • � � � �° �^ o •v.� . � . _J I oo -- � SL - I 00 �I I -�-�N- I � � ' � i j � �°'� ( 8�1 I - - -� - - I - - � � .. ' ', � 4 .D' � I i I . v I i - � 1 •o � � SD� - - - � - - I - - 1--� - - - - - - - - - •• ' SD\ 4 I I I NGRESOS/EGR�ESS EASEMENT I I I � i � � I � ' - - - - - - - - - - -- - - - - - - - - � I � � I I � � i I I . '�, LEGEND: - - PROPERTY UNE --- - - - - PROPOSED EASEMENT LINE D��"�cr�—�^1 .�..�..,+l`•1 1"`�-'"`�R .��.C �1{�j �,�[l' ,.,Y.Ilf-*.�^��� .. '•.. ..'. . _.. ..«...w+�s.:cv �:� _. :. �..,-.� , �r>..��,7 C`..�J� �>� _ .. _. �z .. . _ _...�__ . ���,w. , ` � N 20 10 0 10 20 SCALE: t"=10' REVISIONS � � , C ^ v�� � e Z N �E m o C� ta o°c � � '� � ���� �� m�,� y C 'C C c6��U � CS U u� �or��iz° �J�?� � C (O �i 0 W � V�i �.�> m U � 0 ,�.9�ESSi� ``�'GER D y�C�`�ir, ��No.21755 Z� �l7 �1 V I l ��< rf OF CAL�F� � ` z z �.LJ �/ � O Q � Z J Q Q � U � l.�J .� � 0 z � � LJJ �"_ � � � W � W (/� O � Q � � w � U Dote: AUG 2013 Scale: 1"=10' Drawn: CAD Job: LONG Sheet Z J of � Sheets i I I N � � I � I 20 10 0 10 20 I SCALE: 1"=10' � I I I I I I � I I APN. 357-17-012 � I �I ADJACENT ' BUILDING I I � 7� — — — — �— — � � � 115.00' } � � (E)6' HIGH WOOD FENCE f L(E) RETAINWG WALL TO BE REMOVED TO BE REMOVED �� I I � (E) 6' HIGH WOOD FENCE I TO REMAIN (E)OVERHEAD ' POWE EMOVED� �E) RETAINING WALL—� TO BE REMOVED � �o I 1� � I � TO BE REMOVED ! � HOUSE a� SSCO APN. 357-17-013 �( `� I 1���� (E) 3'HIGH PICKET FENCE � TO BE REMOVED�"� (E) 3' HIGH RETAINING WALL (E)RETAINING WALL I TO REMAIN� I TO BE REMOVED (E) TREE TO BE RELOCATED J � � GARAGE � (E)6' HIGH WOOD FENCE (E)CONCRETE ' �TO REMAIN DRIVEWAY � - - - - - - - - 115.00' - - - - - - - - (E) 8' HIGH WOOD FENCE� �(E) CONCRETE RETAINING TO REMAIN WALL TO REMAIN ADJACENT BUILDING � � APN. 357-17-014 I I I I � � � Z I � � Q i I � ,: a � � W � � � I I I � � � I I I I I I I I I I I I PRO,IECT BENCI-�AARK=PK NAIL L��—EL=I 00.00' I (ASSUMED) � I I I I I I I I � � � I I ► I � � ( � I S I I I LEGEN D�ABBREVIATIONS: (E) EXISTING SSCO SANITARY SEWER CLEAN OUT EXISTING BUILDING TO BE REMOVED EXISTING CONCRETE PAVEMENT TO BE REMOVED ��j� TREE TO BE REMOVED � DEMOLITION NOTES: DEMOLITION IS NOT TO OCCUR BEYOND THE PROPERTY LINE, NOR DISRUPT EXISTING IMPROVEMENTS THAT ARE TO REMAIN. THE EXISTING RETAINING WALL AND FENCE ALONG THE WESTERLY PROPERTY LINE ARE TO REMAIN. THE EXISTING RETAINING WALL A�ONG THE SOUTHERLY PROPERTY LINE IS TO REMAIN. ALL EXISTING PAVEMENT, LANDSCAPING MATERIALS AND REMAINING ON—SITE STRUCTURES ARE TO BE REMOVED, UNLESS OTHERWISE NOTED. D►�-�c>>3-�I p, .�F..., ,rF p.,�.� y �' J��� `' .:���,?�`.�� �.,� :� .;,.� '�- %°'�i x � _ ,_.. _ c.3--��—��. REVISIONS � � � U d 4 I O m O m � 3 d L Q � O 4 E >, � � / W �eu,�y,• ��y,`�G�R D.y/c�"�+ �y o o � �No.21755 Z �l�vlF C 1 V 1��,��e� OF CAL\F � Q z z �..1..� �/ � O z Q '� � Q Q Q � � U z � O O � Z � — � J � � O � �..L� w ° � 0 0 r- U Date: AUG 2013 Stale: 1"=10' Drawn: CAD Job: Sheet � of V Sheets f:I �� [4'� � E�� ,,�� � �-____ ---- -- �, _ �_J------ � � /./ . ('uvement rlush _..�- �" n �- �•• � I I- fi" r. r7• or �icr�cb!e with yi;ll.^.• R_/� R�r��,,, � '. ' } 12" - , /// i a" a. -i- I .. . . .. . , A=�/2'��o 0 I '. •. o�� S.. " o 0 �... �- a � U�O�'ao °0�0 0����7- (,c._------- 4� C!ass ii �gg. base� A1-6 A2-6 �„ �,. I � �2 6" 1 2 74„ ..T •q� -�---. _._ � ,i 8" .R_��,.. I ` • $. +I •��/2�'• �2" cr variable --( • , � 1 4" ' / �--__'_� / � a . .� J Q 9 R�1�2/ �0 � . � pa �d a a • � • e • � � �p�p000' •_ �__�����iiQ�40 v A�-a 4" Closs II Agg. base i��$ 1.00'� 12" 24" R=0.08 H=o.o8 _� 3,. �� G.33' �°6��I , Level Line --� �-�l -J- �,.33� T � _4 R_,�2..�- 6„ �Z~ R=�/2� � TYPE E�MOUI1lTABlE DIt�) �o a o o p o 0 0 ° 4° Class II Aqg. base ' TYPE E �_� , �� , �, If� 6" i �" �-�-°---� � f _�� �- •,� ��. R=���" _L/4f, 6„ N / 6„ R_�/a^ 13/4„ �- � � _J__ � _L. � � �� EPo,y co � 12" - I Epoxy ta E�.Surfoce U Ez.S�rface i 1/Y IongituCinal bar A.C. DIKE EXTRUDED CURB ��2 dowel,minimum 8" 1e�91n, 4'spoc�nq — A� A3�p A3•6D STANDARD CURB SECTIONS CITY OF CUPER'IN:} �APPROVED 9 STANCARD OETAI�S Z ���� 20 10 0 10 20 SCALE: 1"=10' � � - � - - - CLASS III ICYCLE PARKING - ` ONE - - - - �WAY I�� GR=101A '�� 6 INV IN=97.1 12"INV OUT=96.6� ' J (E) UTILITY POLE -- _._� T/i!�A� �� "d.�. wur. ■++.uw yVEAKENED PLANE- �aNr a+cuT JOINT 1/8"WIDE, 2'DEEP ON 8'O.C. �\��4`�� NOTES: 1, Conerete Ariveways not mandatory in Induatrlal zonse rhen aidewalks not consWeted. p, Seore marka not to exceed 4�-0'O.C. Ux m�chanicd xparator at svery other acore mark. 3. Finiah to be Ilght broom. 4. Sidewdk to be roploced whan naw drlvsway la placed S. Edga of Oriveway ahall be a minimum of 4� from ProPKty 11ne. W=Mlfdth 2� 8" M�Z w Z 4•5 «'���° 5'commereial or lndustrid v/ Pavement to be Dsap acore Deap xore Slopa /4 Rebar 18�O.0 both waya flueh Nith Ilp of ar edd +1.5%to+8S guttx p�t w-1.57L to_4% 4�reaidentfal �8•��P �r_�' .� . , - � �'� �••• �` ���-� 4'qma II Agg. � . � oes motxid �'o� ���� �� �Ith a 95x rdoUw � eanpactlon ICommercfal and InduaVld drivewcya i�- ehaA hcve atroipht dope!o R SEC770N A-A DRIVEWAY DETAIL-DETACHED SIDEWALK REVISED 8/2009 CITY OF CUPERTiNO qpp DATE: 1-20 STANDARD DETAILS CITY ENGINEE R/W oR/W U I 70.00' PARKING DRIVING LANE �8.5' 26' � 16.00'� 7.00' � 47.00' I 40.00' I � 5.00' 35.00' 2.00' 5.00' 1.00' ASPHALT SIDEWALK f— —i SAWCUT&MATCH � I (E)CURB &GUTTER REMOVE (N) A2-6 CURB &GUTTER I (N) 1-19 DETACHED SIDEWALK IMPERIAL SECTION NOT TO SCALE NOTES: v conc p„t,,,n,i 1Q INSTALL 12" STORM DRAIN PIPE MIN. 1%SLOPE. �.� z.• a.Z-m;,,. O INSTALL NEW A2-6 CURB &GUTTER PER CITY �� STANDARDS. SAWCUT ASPHALT 12"FROM NEW - - 8• GUTTER. PAVE WITH 8" MIN DEPTH. 8' -� O3 INSTALL 4" SANITARY LATERAL(GRAVITY)FROM CLEANOUT AT BUILDING TO 6�Gm�n Aqg.Goae mo�m�ai CLEANOUT AT PROPERTY UNE. CONTRACTOR TO VERIFY EXISTING SEWER g'Goss i��qq.bax motRiol . with a 957i re�otive canpxtian LATERAL. rith a 957G r�loti�.e tamPOetion 6'x fi'-10 X 10 wre�d.Ke mean 5¢cnor��-� �4 EXTEND 1" WATER SERVICE. RELOCATE METER. Trvicw secna+ STANDARD VALLEY GUTTER RENSED 5/97 CiTY OF CUPERTINO qppROVED 8 DATE: � Z 1-18 STANDARD DETAILS CI , INE R ' GR=100.5� / �� � � � QS T QS INV 98 0 QS i - - -n . _ - - - - - - - - - - - - �-- - - I 3 �N) WM 62.50' a I � 22.00' � � . a. �.�N� .S.C,.�.. . . .'° � .�� , . . � . � ' . � . .• . •. � a . . .�o � .a • i� � � . . � - . , � . � � ��. ��v�. °-' - . • , • , . , . ; . . � . • � .a � a w , • , , - ; L/5 �� � , � L/S .` \L/S O �E� � . # ` • • � a. 'o � (E)SIDEWALK i __ 2,.oo' (E) CURB &GUTTER b CONFORM O LIMITS(N) A2-6 (E) CONC. CURB OVERHEAD CURB &GUTTER � - CURB_&GUTTER -c nFWR�&zD 8 � _ �UTfC11TE5 - --BcSIREIAl9LK __ _�'N REPLACED BOTH �N, ,2' DRIVEWAY �N° I M P E R I A L AV E N U E SIDES APPROACH PER CITY • �n OF STD. 1-20 STREET SDMH o RIM=100.04' / SDMH 12' INV IN=95.8� RIM=100.26' (ASPHALT) INV=94.5 �,H -- (E) UTIUTY POLE &LIGHT� (E) CURB & SIDEWALK--�\ \v �� �_ _ �-----21.00`�- (N) A2-6 CURB (N) 22' DRIVEWAY &GUTTER APPROACH PER TYPICAL CITY STD. 1-20 -__ -_ -- --- -- � REMOVE(E) DRIVEWAY PROJECT APPROACH BENCHMARK= PK NAIL EL.=100.00' (E) CONC. VALLEY (ASSUMED) �GUTTER LIMITS �(N) A2-6 CURB &GUTTER CONFORM � ABBREVIATIONS: (E) ExISTING (N) PROPOSED L/S LANDSCAPING O.H. OVER HEAD UTILITY S PIPE SLOPE S.D.M.H. STORM DRAIN MANHOLE S.S.C.O. SANITARY SEWER CLEANOUT Wbl WATER METER GR GRATE INV INVERT LEGEND: - - PROPERTY LINE - — — — — - PROPOSED EASEMENT LINE SL NEW SANITARY LATERAL SD-- NEW STORM DRAIN � DIRECTION OF SURFACE FLOW � 18" X 18"INLET • 6" NDS DRAIN SPOT ELEVATION � ASPHALT CONCRETE PAVEMENT a p 1�-�C 1`�j�,�1 i� . �t -� a t s x �,l�/.6�.wll J-,. ,. �� _- ,,-,.._...... �.. , ; �_-.� _ '��,i�:�.. `�' - , . ��-/�-%� - -�... r• -r- . •'�� CONCRETE PAVEMENT REMOVE TREE REVISIONS � �, c „ Cf'>. � C Z N �o m �� 'N�U !/i 7('7 p�1 C-0 ��0.5 �� c -d a,�a� �� mU�� ��� �p�w C c �moMO� :i� J O C�7?Z � � �J�5 � � O �W � d 3 Z"> m U � 0 �QfpFE$S/p�, oG�R D./y�CO`r�+ ��No.21755 Z� �l9 C 1 V 1� �\r lF OF CA1.�F� Z Q � I..L._ I- � Q W z z � � � WQ �..1.._ J J � Q Q � � U � w � L.� O W � � � �- N � w � � � �.L O � O � U Dote: AUG 2013 Scale: 1"=10' Drawn: CAD Job: LONG Sheet � of � Sheets es ems . . min earin _ _ , George Schroeder Subject: FW: Pasadena property-thanks for inferring which property I meant From: Gail Bower [mailto:gail@voltage.com] Sent: Wednesday, September 11, 2013 9:00 AM To: George Schroeder Subject: RE: Pasadena property - thanks for inferring which property I meant Thanks George! More for Public Comment: What is the success rate of transplanting an oak of that size and having it survive normal lifespan in a planter? If less than SO%it should also be required to plant a large box size oak(from tree farm/nursery} that will be much more likely to survive somewhere on the property—perhaps where the pepper tree is on the west boundary. Could the city strongly recommend that they consider planting native trees in place of the Flowering Pear? I would love to see the city help support, in this way,the expansion of native plantings (trees and shrubs) into the Monta Vista neighborhood to support all the really great native plant work the city did at Blackberry Farm (Monta Vista's neighborhood park). Thank you, Gail 1 George Schroeder From: gb136@comcast.net Sent: Sunday, September 08, 2013 8:07 PM To: George Schroeder Cc: Gail Bower Subject: Pasac6ena property Hello George, For entry in to public comment - I'm writing about the commercial/residential building for the old house on Pasadena. I"m sorry I don't have the address handy- I can send if needed - it's directly behind the Monta Vista Market parking lot. There's a very large pittsporum and an 18" oak and a large pepper tree with removal notices. That pittsporum is a wonderful tree and is simply glorious in the spring when it blooms with a fabulous fragrance. Where is the 18" oak to be transplanted? Why does the pepper tree have to go - it is directly along the property line in the back. The new building drawing shows a only a few minor shrubs -- they should be saving the trees. If not they need should be required to replace the trees with natives - with trees that will be tall enough to soften the bulk of that 2 story building (not crape myrtle -- too much of that and no wildlife value!) and they will appreciate the shade to protect from hot sun. Also it will conform with the tree placement of the other similar buildings in the immediate neighborhood. Look forward to your reply, Thanks, Gail I hate to see mature trees summarily removed - we need to preserve the trees in Monta Vista for the aesthetics, shade and quality of the neighborhood. Thanks, Gail Bower 10095 Orange Ave. Cupertino CA i