Loading...
13060213CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 20668 SUNRISE DR CONTRACTOR: CHONG RAYMOND AND PERMIT NO: 13060213 . PATRICIA OWNER'S NAME: CHONG RAYMOND AND PATRICIA 20668 SUNRISE DR DATE ISSUED: 06/26/2013 OWNER'S PHONE: 4082217918 CUPERTINO, 95014 -2929 PHONE NO: ❑ DECLARATION JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL ❑ LICENSED CONTRACTOR'S License Class Lic. # REPLACE FRONT ENTRY CANOPY WITH STEEL FRAME AND Contractor Date GLASS CEILING I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self - insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $15000 performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 35910035.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 DAY LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, rM costs, and expenses which may accrue against said City in consequence of the �� ✓�p, /3 granting of this permit. Additionally, the applicant understands and will comply Issued by: Date: with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. RE- ROOFS: Signature Date All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. _ OWNER - BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self- insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Cod ons 255 25533, an 25534. j� Section 3700 of the Labor Code, for the performance of the work for which this �G " permit is issued. Owner or authorized agent Date I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, ARCHITECT'S DECLARATION costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupert' o-Municipal Code, Section Licensed Professional 9.18. Signature Date �qn / �yt.esss • CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014 -3255 (408) 777 -3228 • FAX (408) 777 -3333 • building acupertino.org ❑ NEW CONSTRUCTION ❑ I� ADDITION ALTERATION / TI El REVISION /DEFERRED ORIGINAL PERMIT # PROJECT ADDRESS - ' N� � J a p.�.a APN # OWNER ; (R� PHONE -MAIL (� o EMAIL j F �fJiJ STREET ADDRES �a Ste- ►tired -e w. w e,�a F 1i CITY, STATE, ZIP FAX CONTACT NAME. 1 p ff V�v1 PHONE �o16 ->-)4 '►-ztIt E -MAIL STREET ADDRESS L N' ! _ � \ �r �e CITY, STA P ❑ OWNER OWNER- BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTO N a � LICENSE NUMBER D LICENSE TYPE BUS. LIC # COMPA�I - MAIL .jAM)�� STRE AD DRESS r�C CITY, STATE Z� 1 r�� f•e� 1 r �V1 ] T P ONE ARCHIT /ENGINEER NAME LICENSE NUMBER BUS. LTC# COMPANY NAME E -MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OF WORK D V,-D La w . � EXISTING USE PROPOSED USE CONSTR TYPE # STORI'ES USE TYPE OCC. SQ.FT. VALUATION (S) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA NET AREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: DETACH ❑ ATTACH # DWELLING UNITS: IS A SECOND UNrr []YES SECOND STORY DYES BEING ADDED? []NO ADDITION? []NO PRE - APPLICATION ❑ YES IF YES, PROVIDE COPY OF PLANNING APPL # [] NO PLANNING APPROVAL LETTER IS THE BLDG AN ❑ YES EICHLER HOME? ❑ NO "xR- E,GEiyVE yx ' a ka & .x+ TOTAL VALUATION: By my signature below, I certify to each of the followin : I am the property owner o orized a nt o act on the property owner's behalf. I have read this application and the information I have provide oaect. have read the Des Ion of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to build* o constru orize r sentatives of Cupertino to enter the above - identified operty for inspection purposes. , Signature of Applicant/Agent: Date: 6 SUPPLEMENTAL INFORMATIO QUIRED G IL10 unrlT?i!G$LIl'1 IN= W4 P,LANCHECKTYP _ New SFD or Multifamily dwellings: Apply for demolition permit for OS?ER <THFrCO •�'TLR. � ''` �� existing building(s). Demolition permit is required prior to issuance of building— BUII,DII�GP3,t�TRE permit for new building., r� �tvrG i Ai�ir _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure form if any Hazardous Materials are being used as part of this project.Y TAIVDARD rus ° cwoRxs { _ Copy of Planning Approval. Letter or Meeting with Planning prior to airI4IA70�t �� a 3 SANITARY S$�i ERNS RI '- submittal of Building Permit application. ,.,� �.�'k'�,r .- i.- .... -_e_ ..._.�._ -....v .� ���tEl \'VIRO.IYMENTA'I�`'�EATSTH._ ._•. BldgApp_2011.doc revised 06/21/11 Fm_� CITY OF CUPERTINO FEE ESTIMATOR — BUILDING DIVISION NOTE: This estimate does not include fees due to other Departments (Le. Planning, Public Works, Fire, Sanitary Sewer District, School Tlicfrirt ofr 1 Thoeo fooe nro hneod nn tho nrolissainnm infnrmafinn nvailahlo and nro only nn octimato rmitart tho i)ant far addn'l info_ FEE ITEMS (Fee Resolution 11 -053 E . 711112) ADDRESS: 20668 Sunrise dr DATE: 06/26/2013 REVIEWED BY: mendez APN: BP #: "VALUATION: 1$15,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex USE: p 0.0 PENTAMATION 1GENRE PERMIT TYPE: WORK front entry canopy with steel frame and glass ceiling �"e SCOPE $0.00 NOTE: This estimate does not include fees due to other Departments (Le. Planning, Public Works, Fire, Sanitary Sewer District, School Tlicfrirt ofr 1 Thoeo fooe nro hneod nn tho nrolissainnm infnrmafinn nvailahlo and nro only nn octimato rmitart tho i)ant far addn'l info_ FEE ITEMS (Fee Resolution 11 -053 E . 711112) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 = # Awning / Canopy (Support'd by Bldg) $334.00 1AWNATTBLD Canopy Suppl. PC Fee:. (E) Reg. ® OT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Feeig Reg. 0 OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Construction TaX. fl.rlrnirlist�°�ative .h`ec�: Work Without Permit? ® Yes (E) No $0.00 Advanced Planning Fee. $0.00 Select a Non - Residential Building or Structure i Travel Documentation Fees: Strong Motion Fee: 1BSEISAHCR $1.50 Select an Administrative Item Bldg Stds Commission. Fee: IBCBSC 1 $1.00 _ $2.50 1 $334.00 0! _ $336.50 Revised: 04/29/2013 s OWNER- BUILDER DISCLOSURE FORM COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014 -3255 (408) 777 -3228 • FAX (408) 777 -3333 • building a-cupertino.ora Dear Property Owner(s): An application for a building permit has been submitted in your name listing yourself as the builder of the property. improvements specified at:' SITE ADDRESS PN BP# OWNER t+lpM ` l Ct 0, OWNER AD�DFjE ���1 lWV CM el jjjj DESCRIPTION OF WORK: P o „4- We are providing you with an Owner - Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner - Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION (DIRECTIONS: Please read and initial each statement below to signify you understand or verify this information.) _!/I . I. understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner— Builder” building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner - Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner - Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. V (- 2. 1 understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. _e_L3. I understand as an. "Owner- Builder" 1 am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. PL-4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. (-5. 1 understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered. an "employer" under state and federal law. L6. 1 understand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. 10�6�7. I understand under California Contractors' State License Law, an Owner - Builder who builds single - family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed. subcontractors and the number of structures does not exceed four within any calendar year, or all of the. work is performed under contract with a licensed general building Contractor. � -8. 1 understand as an Owner - Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects. in the workmanship or materials. OwnerBuilderForm 2010.doc revised 04114110 ,LL-9. I understand I may obtain more information regarding my obligations as an "employer" from the Internal ... Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1- 800 - 321 -CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. � V10. I am aware of and consent to an Owner - Builder building permit applied for in my name, and understand that I am the parry legally and financially responsible for proposed construction activity at the site address listed above. OC- 11. 1 agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner - Builders as well as employers. X12. 1 agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. if you obtain a permit as Owner - Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. CONSTRUCTION LENDING: AGENCY. (DIRECTIONS: Please complete the following construction lending agency information.) I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097 Civ.) Lender Name: Lender Address: Before a building permit can be issued, this form must be completed and signed by_the- property owner and returned to the agency responsible for issuing the permit. Note: A copy of property owner's driver's license, form notarization, or other verification acceptabl city maybe re to be presented when the permit is issued to veri fy the property owners si nature. Property Owner's Signature: Date: 6 (NOTE: The following Authorization F--o- orm is required to be 66 m-- pi-fie­t-e- W by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner - Builder). AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner - Builder Permit for my project. Scope of Construction Project (or Description of Work): Project Location or Address Name of Authorized Agent: Address of Authorized Agent: Tel No I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note: A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: Date: OwneYBuilderForm 2010.doc revised 04114110 Bernard Huang Structural Engineer 1121 Farragut Blvd. Foster City, CA 94404 BY STRUCTURAL CALCULATIONS REPLACE FRONT ENTRY CANOPY CHONG RESIDENCE 20668 SUNRISE DRIVE CUPERTINO, CA 95014 BY: B. H. DATE: 6 -24 -13 JOB NO.: 13033 pa''br?7ent jlj/v 2 S) t) REVIE�VFD fiCR COpE Co f` evjeWed By. � MPLIANCE 4ROE No. 2954 R r EXM:S fr30 2014 # �r `p�qr �RUCT�RP F OF C p, ��r� Bernard Huang Structural Engineer 1121 Farragut Blvd. Project: SUNRISE Pp-. 23033 Foster City, CA 94404 Job No.: By: B. H. B. H. Date: 6/24/2013 Sheet: Vol 114 TL- Q ooh' 7, 4 ~I -Ae "T -rz� r/v P_" 2 Bernard Huang Structural Engineer Project: 20668 SUNRISE DR. 1121 Farragut Blvd. Rafters Job No.: 13033 Foster City, CA 94404 Gyp. Bd. By: B.H. 0.8 Dead Load Date: 6124/2013 20.0 Total Load Sheet: Al GE ERA 7L ffC-0—P—E77 Replace front entry canopy rC-0—DE--1 2010 California Building Code MATERIAL Timber: 2x - D.F. #2 4x and 6x - D.F. #1 Steel: A36 Weld: E70xx Bolts: A307 DESIGN LOADS EXISTING ROOF Roofing 3.0 Plywood 3.4 Rafters 3.0 Insulation 1.0 Gyp. Bd. 2.8 Misc. 0.8 Dead Load 14.0 Live Load 20.0 Total Load 34.0 NEW FRONT ENTRY CANOPY Glass panel 10.0 Steel beams 5.0 Misc. 2 Dead Load 17.0 calc CHONG RESIDENCE 20668 SUNRISE DRIVE CUPERTINO CA 95014 GENERALNOTES CONN.- ConneMlon CONSTR: Constmctbn EXP.- E—illon EXT: Eyed« H.M.-Hollow Moral HORIZ: Hol-1.1 DIVISION 5- METALS PAINTING DIVISIONI - GENERAL REQUIREMENTS GENERAL INSTRUCTIONS Stmdu d steel shall omhem to ASTM (ASS spengiodbns and to the AISC meofflcaeons for fecogdkn and «ecmn. Seal, Rime, puny, Mpackb, OOdk «othem%e Prepare all that —tom pointed. Pdme end paint all aposm motel roofing scows ides, sheet ,Mal fleshing, plumbing venU, on , In a ago, to match adjo —t roof Wvedng GENERAL INSTRUCTIONS Al l boils shall conform to ASTM (A� 7) for unfinished bona. ,stands. Protect e. adjacent materkb from owesprry, spamn, tripe, «other damage. required. Provide 12 APPLICABLE CODES A Caaomie Fire Cad -2607 (20061FC) E. Ceitana Electrical Code 200] Ediden aI bit Insist, In dad number shall he tore. Burning of mm for the mmedbee will m m pamMad. Provide full bearing m unmreade ! o ion of soft shank 1. all steer some ndons. gab. of each mior and type Of paint and Main used a the Owner upon mmpolon. Cd« sdhema b be ddemmined by D.gner add Owner and sdeoted from the mhdmi range d cd-, B. Calaornie euitdm Code 2D07 (2006IBC) F. 2007 Can i. Energy —mot, Sh ndard C. Caigoma Mach. Code 20 g7 Ellison G. Any other pgkade bml and sale law, and regulations Prontla Iwd bons 1« all bola d bean amts end column base pates. al ores lR Stmcturd saelmnrdeabns Meat mhea✓y nmmgmel nuts. DIVISION 10- SPECW.TIES D. Calg «na Plumbing Code 2007 Edtbn al welling shall the Mlntlkehl on ere Malls ands perfRmed In It qualiied.hm. under cWgnuous inspection per U.B.C. THIS DIVISION NOT USED Ta metre se-dull venty all dmenaions, dwations, and otndrom; Prior to sadirhg any laldwak. 306. Field welding, dhe, men maodbmeous tads wading, is not permimd, ur., oll —de. noted In the deans. DIVISION 6- WOOD AND PLASTICS DIVISION 11- EQUIPMENT Fronde aft instill all souitrent aft sppllcemw inokrdbg d required ommecfoM, finings, trim and aoc rtes Typical desk Mhall eppN' More no spedlic dealt, «sections ere provaed. LUMBER GENERAL INSTRUCTIONS Mr 'NeIked 1. a oorrpu- ineaatlon. Owner a Rnida Contractor ent, cal -sheet teacnlutlon d all Oweer selected —omen) Met apgkanoss. Dimensional shown W pans a Mail ale Rsceded. ores soeles sham. FOR STRUCTURAL PROJECTS PLEASE SEE STRUCTURAL SHEETS St FOR STANDARD REQUIREMENTS. . Wood mernhera less titan d' In war shill be in Darglm fir No. 2, a d' w wlder sal he In Douglas Flr No. 1, unless DIVISION 12 - FURNISHINGS Ter oted snail he resPmst for fe aade—y cangegon of an work In amo —with me prolecl otherwise nomad m me pans. Prwded on the Furniture Plan pads Met mocithraEOns. aI cmddctlng hardwan , mail se SimpeW Cohn—y tape, O.A.E. aril Instalalkn she.. In amrdadce with 1. Manufacture`s requirar�MS, mass noted otherwise m the Pan,. DIVISION 13 - SPECIAL CONSTRUCTION Al work eral commit a to —matt which iMudee the owner/mntrecta agree, -, the project manua (whkn somas the genaal and'.pplarenary mndtioee arts Bre spedlkations, the hewing, and all addenda and GIU-Ladeetad manor shill W of a combination Rwairg a minimum Fb -,100 PSI. Canby m mehOs ed on me plans. Roof shedng shellbe It minimum ofM'CDX pyw'Ood with aQeror glue, Group 2. EXOCsedslearl at roof Aarhang shill THIS DIVISION NOT USED mmgacetiau aaued by the ImMis, designer. he m iridcded W me Des9nw's Plans. . WNl ahWhg,nneoukedsh 1W,,klmum01318•CDXpywoO hadedagiw.Gnwp2.Swlt pmslorsimMe, DMSION 14 - CONVEYING SYSTEM THIS DIVISION NOT USED The ood— mail renew all documents and v-My all dknaMkns ad held! conditions and shell Whim that work a beildabiemshowm. AnycWilkt or omissions,dc. snel heknmeriday reported atheFUbrd.gner for hatded . Bearing and son - beaing walk andl hale douse aygew, tippedalntersmbee. Pldejirdem.11besaggered 4'-0' DIVISION IS•MEGUWICAL. cterinOOlbn Rior momha pertormarhce a anywod in qumtim. minimum, as Indcatee on the Structural deeds. . Un s,, otludMSe noise W ma pane, eaerw walla snail cool 2'k6' ands and Inter «wilts shell be d 2'x4' stun PLUMBING SYSTEM Daeestk wets soppy, helnaga, waste, vantlnq, and neural gap soppy piping ryeema ahal he designed, Tle interxx dMigh. net no knowledg -of ane,hdl not lea hadlinba for any M1ezerdW$md.es «ton pbefte,8 (Mud grade or baton) M 16' m center. a—iied end Insisted! IV, the Pumbing sumanse— Layout, piping along, joint lypea, oonnmbms end all my hazardous matedoal are discovered during— MUd'on me contractor shall ladle the alfmted area aft mitred the ownerlaludm instmcuona helore pracemug. Al l ostler$ Melhe. noted on ion pans. alwoadbearingW maxatheamemoryshillWKe .,t,e Degas Fir, Rmwad. Hoes fa softs,hall so bored wfth a411/16' lager than ine rdmdina bpk elamau. All sots shall se rdghtenod Rbr a m.na of system suppM analhetldenninod by the plumbing eubcaniracW. al mpkede robes, jurladduu requl reman. and ganerdly nocesed --1d 9md mnadudim precgceregardg the system design. leeallatlon end operalen roll m heel a exaheeee. Pronca es-coln drewings to Owner upon mmgalm. A9 wod shall W mdormel duringregular cosiness hours where—pm,ibla. Work InmMng excemNS rise or aisioaan of plywood, gypsum hoard, etc. FTG: Fmtlng FURR: F-m g Mil, a which would dheweainterferewith thenormal oral of the fsoilnyshad bedonem an oWnNe, nth- raguated bsaines, hour beats to W marinated with the ow.,b reaesentanve. Shedud —We shaft sothe art for pros, Mo.,-I. apedfioadly noted a deailual 2'x wit dmking snal he gaped Lanveen joists or raters al dl supports. Ail bra hearing m wood snail have standard wt wash-, under head and md, unless noted otherwise noted m fe DIVISION /8- ELECTRICAL ELECTRICAL SYSTEMS Electrical system design end Installdbn andl be the rmpenalblllya the eleclr OOl sumoMraYor. Number, location -ALIGN' shall mean a. —Inly Irate finish lame In ton same perm. pans, and capacity d mouse, oprdudor aOM. and all other noecashl amdana for a compile and fumlWing system TYP'shall w the the mndaW is reResenatiw- for similar condNms throughout, unless noted Otherm- . Maus", cm.aed We shell he 10' -W. Prone. 2k full depth Wood, a dropped adla, -m m eaves, fioord end Other locekns. required. hall m prwide0 and Instated. ElectrlOOl M.hm ud «shall Indicate on Resod Drawing as provtled by the Designer, ine dmun desgndbn Deasiis are usually keyed and need TYP ony once, when they.... NAILING (circuit breaker number) m mch man panel and sub-mnel, emh lighting fiau e, OWVenimce o0st, apgiance, etc., antl reum cols Rlnt a the DeagnanOwme. al — M.otas a m insulated mid copper. 'SIM'mail mean —Maude characadaics for the mneitimsnded. Verify dimensions and o,Imtag,n on pans Al wo,ilamirg members ahMlhe wall- nand and In— da.with UBC, Taae 25C. al nail expmed to weather shag, GL:OIa. and a—... m- dipp -d Ortnedzed. PlMw ,hwtingm"y ,Wl dwithpneumaknailingmuipn t,ROnd thWplyroM a Mane sot Peroed by nail heads. Nets a he hand sal as required. Nail shmting a ,ding a StnudurN Notes W Structural pans. /�/� UN' ^J� ^yl.��' CompY with engkable foul, Me, and fed -rd md-s any regulebna pedanirg to safer Ol persons, properly and OND: Grouts GR: One le /����� ,/'�`/ 1 D I R ECTO... - " DE _ EL anwronreental Rote Mon. METAL FRAMING ACCESSORIES Shermed and labrkated sea of the type lndiOOted m reariretl using ma es sappier by nunufedu e, for this sWRI, use. ENCL. Emceurs Work areas are to remain semre eft bdMda dud W"— . Centranarandlomrdinaatoen.... Remmw from she and legally dispose d daily aI reuse. debris, Mbbish and other materials retuning from Nalsshall mlullIm"lnmotbsofamoh— veered. ProMOacanfo.ingtomereoul.em ,halloo RaA wd Instaled —Nucad by the mans esums. al matd lMming amessodes shall m gaven¢W ,,hopminted wit m,t lnhaniw paint ielor a Insulation. Owner: Raymond &Padre Chong S. We Dive � �� demditi« operdions. Burirg d dabds on she steal rat m permitted. FINISH CARPENTRY 20668 Cupertino, CA 95014 4t)6 221 7918 ABBREVIATIONS & -And ® -At CONN.- ConneMlon CONSTR: Constmctbn EXP.- E—illon EXT: Eyed« H.M.-Hollow Moral HORIZ: Hol-1.1 REFR: Rem om « REINF: Reinforce C- Cent.m. OONTLCWllnuou. FA:Fkeaann HR. -Hour REO.O- Required C- Diameter or Round a -Pound or Number CORR.COrddor CTSK. Countersunk F.B: Fat Bar F.D: FioorDUn HOT. -Height INSULAO.uion RM. Room R.O.-Rough Opening (E)-Eommg ACOUS.- -Lustkal CNTR.Coad. CTR.Cet. FDN: Foundatlon F.F:Fklsh Poor INT:Intmo, JT..kint RWD: Redwood S.C.-Sold Core ADJ- A4.Mose DBL.-D.- FIN: Fkkh gT.40t hen SCHED.Schadub AGGR- Aggregde AL :auMnum DEPT: Do-1— DET: Daall FL: F— FLASH or FLHG: Flashing LAM: Larninde LAV: LawtM SECT. - Saab, SH.Slen APPROX: A.rotlmde DIACame. OWR: Ddwwer MAX: M.... SHR.Sbower ARCH:ArohftW hW ASPH:Arphan DIM.Dier-Mcn DISP:Dispenser FLOUR -F —anent M.C.-Meddm C.N. F.O.C. -Far of Corwde, MECH- M—whoM SHT.Sheel SIM.Sknlar BD :Board BRUM.- Bnu.nout DN:Dwm D.O. -Door Opening F.O.F:F —M Finish FASFecaa Blud MEMB:Mambaee MFR: MerMadurer SPECS - Sport -W SO.Squere BLDG: Selldkg DIR Door FPRF.- Fireprsol MIN.- Midimum S.S: Stdnba Steel BILK- BloodN BLKG :BImkinB DS:Downaproes D.S.P:Dry SaMgpe F.S. si. FT-Foot «Fast MIR.Winsr MISC.- MlscelWUma STD:ShmWJ STL.Steel BM.Seam SOT: Batton DWG: Drawing E: Esel FTG: Fmtlng FURR: F-m g MTD: Mou nted N: Nam STR.StmcturM SUSP.S.""s d CAB: Carina EA.-Em, GA -Gauge N.LC: Not In Contract SYM.Symmeldcal D.B. -Gild, Basin CENT., --t E.J:EMaeebn Jdm EL- Ea.tbn GALV. -Gus lb G.B.Crab Bar NOM- Nomthal IN T.S.-Not to Scab T &G -Tounge aft Grows THK -Thkk CER.Ceramk ELECT:Elactrkal GL:OIa. O.0 :On Center T.W. -Top of We$ C.1: Cast Iron C.G: Comer Guard ELEV: Ele.dm EMER: Emmgancy OND: Grouts GR: One le OPP. -0—sl , PL: Plan TYP; Typcal U.N.O: Unasa Noted Otherwise CLG.Caling ENCL. Emceurs GYP. S0: Gypsum BOOM PLAS.- Platt« VERT: Vert CL.Cbal CLR. -Clean E.P:Ebotrkd Pmegoored EO: Equal GYP. - Gypsum H.B: Hone Bibb PLYWD- PNwoad PT. -PdM WAWith W.C: Wder Closed C.O: Cased Opening COL.Coamn EOPT.-Equlpmorm EX ST. -Exist H.C.-Hollow Core HDWD: Herdtosd RAD. Radius R.D.-Roof Dnan WD: Wood WP: Waterpod CONC. -Cmaea EXPO. -Eq—M1 HDWE: Hardware REF: Ral mce WT: Weight BUILDING DATA ORemomldgaW, oofatfrontofhmm ,ndebrywindowereardhou,e. Remove of"Ing fireplace and cnlmuey. Remousld pergoia arudure In from yam. Most wale with horizontal radar eking. and rdo.Mloh of trews (a. site pan). Subnilulon., rwislonsor d mg. must m submitted to ma interior deaigeer la renew pd. to Wrchaae, CASEWOflKANDCOUNTERTOPS lebrkatbin «Instigation. Camwwk shall m designed fabricated and insuad by we (t) manufacturer. Counmertms shill m Maligned faGkatstl, and This set Of lens and .1' Riser d hqur� Insaed by ens (1) manufmurer. Casework antl muntedoP tl.ign, mdedals, IlnkhM, dapr styl -, nadxane, antl Daagn.: David Mast P swi f F./\nls �/ p{Laer �w u� Ramses, tools and aquilrnent Iran ere upon mmpdiW Of work. Leav- Oomr- re.elh.cloan,onterlyam emmawres shall he .Iected by designer and aperwetl by Owner Prior to fessnomen antlimalbtim. al ROMots shall reed Dead Mast Design waYaMIfIB�dR �0 eo ur in mrrsum n- .mlxNafn mw Or One, mactmctloh err attested! mMm odah' W11oaflons, of me achheduu Woodwork Institute. 3B]t A 191. h d._._._. inh eitn liirinn All work shall he oax6need with the sewer§ repreeenalNe krLdng scheduling time and lock lOn, for daiveries. INTERIOR TRIM boflding Mmes. building fadkhes d�ing all phases d work Minimum distuded- d aaaing Wilding furehos, antl Door end wlMOw OOsirgs, bassooards eft Omer macellansous trim gamatobe seated by Dmgnerandepprws,dby axuPada at essential. Owmar. The scope of work and adimar t mess (mdudng'pah of moose and lobby where IT applies to the work) shall be profecied Iran ewtlamag -that axu, beeau.ame work. Arty dandale flu enure ahallbetlre ilneneia repormbiliy a ton amba,t«. SUSMrTTALS AND SHOP DRAWINGS Con4acar shell sure ache resigner, hso (2) sea a dooumeMabn for Prod ots inanded I. u. On this RWed wfhare Sudnine. a Shop Dresirgs ae regared or otherwise necessary, la the Dog—'a sp edhal. Rkris fabrication. REQUIRED PERMITS a k m o CmbacarwNl be reslansibaa payl «antl mare dl Suldn9 end Tleda Persona repaired by th JUrkdklen npiea tlhe wok PRODUCT SUBSTffUTIONS MRo&ds lmPrwkatl MspwMWwiththesiNg exceptiondpoM diowed M•ORAPPROVED EQUAL'(OAE). Substituted produds will be Ts aPPro.d In writing. on" the Designer Pror to Installation. Vessel sPRwae ere apanficalN Rehibled. Wot MbstlmhdWa willheallwvetl. Thera «etm COntradarwD ressumsf Products RwiMeantlkr kstdled but sot tip ilietl. Cant,carsmleapply Desigderel. Mm(2)sead , WiedinwdtigmyeendtmlowsampanlaanryprodudMkhemnakbredI« hathullon. Conlrecfor wilbemnadk wMly anY aciuPable Ralal substllutiaa. PROJECTMEETINGS _ rgighordllhe.PRiod a�croshudlontrConba! «wl .r hr. with the aqurest dmfpmlanpa Of the Work to the Intent of the Contrast Doeumemtion pd. to anrer ring for j.d dktbmnaadd d kapeaflons. Dmign«vdllmlaetihe Workamumlmthe Mead Subu tal COmpMw&WFiWApproval . mouaded by Comedor and Preapprwad by Own. ERRORS AND OMISSIONS Eno, dacrepenct$ and oml.bns th d may «cur In documents shall he brought to the attention of the Designer In writing and written dd'dicetions shall m odan -d adore Proceeding with the Work. The Cmmractmedil m held Idly re 4sihie for the rmuns d aw arm, discrepancies. or omissions of whicn the Cont—tiled to miry ft Design. sofa. omstruod. author /mkatbn of the Work. DIVISION 2 SREWORK THIS DIVISION NOT USED DIVISION3 Cmade f« Mam on ground, beam footings, or pars shag hem a minimum otmpre.iva slrangth of 3,000 PSI M n days, unlms need ollerwiew m pans. Maamum ag9regaa size shalhe3/d'antl meamum slumpbe4X'. Anchor lags, anne n bra, tlowets, entl other reouired insects Snell he pOO8lmed and Ikmly semretl in pia a bMOra l W e MI is pmretl. The a—m ar shag We all the necessary a eemres to prwibe a proper mmmctim a the a fo ting The axcavaad moan d as — tion.shall be.0.fom a aeVMtiW3 shown on mails and the Igotinga shill be insured in eeat excavatiens, withwl slda isms if Rssiba. REINFORCING STEEL Ralniordng Steel shell m mormetl ors, mnfaming to ASTM A615.40 rmuirements and waded wire mesh, our ASTM SPECIFICATION A-195. Bars No. 4 and smaller shill W d grese 40, and Bars No. 5 end arW salt W d grads, 60. Ap raMordng bas shell he dean of any rust a foreign materials. All unhucing Morose shall a auPed w'room d W our dlanetars, soon m less man 24'. ee cws,rege for unlorcamenf shag be: 3 -where poured against —In; T where Foured against fords: 1' fa st poured against forms. B. Para /« quantiy and bcatbns d andor sons. Locate bons withk 12' d comere ad bdljdna. DMSION 4 - MASONRY GENE RALINSTRUCTIONS al neo- ssarywak addl m rebfaad graded masonry aft ,dam a me 1994 Ungar Building Code and shall beNo B;d'xl6' Ighivrelghm units with maximhxn linear shdnkege d 0.06Y, per ASTM (G9P52), Grade A. CWt'nucus idspmbn a required. — 'dofMullmcanm.tldare sort PMiandcement coo nd more roan our. paa cord. Grm mix shagbe c Wage to si aredudn 4'he cemu tliratmere heW titrespadssaneandwiassthantwopea Reel. Wills a he Routes n uni unn c— Aga, foie. high Ion grad prouMdur. (won blpckahta) ere uMd. At anfor 0. anal had a mnmum coinage d X' d ryad. All bogs shat be provkm with an apprared moisture inner On the rid ode. FLOOR UNDERIAYMENT Page board umedayment of esters", mkkness shall he used to hog adJaeeM finish Iioodig material to ung«m elenatim. Sdin edih.Ne heddun8armlhkhnaM antlattedhasubibor with steplm orapprgdae anglhd6'O.C. reamer. Dft D 7- THERMAL AND MOISTURE PROTECTION GENERAL Ad mdeare protedion Is a W Installed Per manuamrrers spedUmtbns aft at e manor Me to Fewmt leakage FISREGLASS BATT INSULATION FaiMaceq heargam lent ksuukn all W kerillee with log facing towards dodimnel span, with .taping flanges, . —rely tiabrdetla fe FedelamM d iremirg nennbers per mandadhaerk leetrudbns. A.lette shall IA mu*bsewem franrdhg nemmra. At praduots to he ft. 0"' (1) mandx4uer m fdkwa: ENVELOPE INSULATION SCHEDULE Laatlon: Type: RMIMtl Fioa Befitislkn Ederkr Walk Batt lnsuuan Veumd Caging (Arc) Bat h s dam Vaulted Calling (no Atm) Belt I —led Fu Celing(wnIn Aft) Bel lnd'st" For R- Value. Me Enmgy oakuuims, and sections. FOAM SEALANT _ interest. wines- framed eft gap chadded M WIly and other penetrdon.of the to W «Iw spa, heading e�aalew wall sole pate- t—Mloo, joint (mendxkrerb kealdkn spectikatlons supercede Ion use of loam seeleM). JOINT SEALERS AND CAULKING Eaemjoimt Milers and oauiklrg tom ailecowlsesed and In a odor to meth Mfaserm finish. (or pelnade f Mdjeronta gnkms Me to be painted.) SHOWER PAN On ground 1y shall he water tight. mnehuded with approved mderu, Mdmuday reinforced eft with m epROVed gangs Moor draft. Uning to be pfded V4 per foots weep hots In oink. (411.8 (1) CPC) Above ground rye, wain ght timing minimum of 31nohm Mows, finished dam height. Gem to he at had 2lnchm higher than high points of finished shower flan, but not more in. 91nches. (411.8 (2) and 411.5 CPC) DIVISHION 8 -DOORS AND WINDOWS al doors ere sold sore doors or temperetl ga.. al do «s and reuetl amass«ks are a m Mlecletl antl eppro�ed by the Own. aft desigran. DIVISION 9 - FINISHES GYPSUM BOARD — reguian type giTaum hoard shnak st Interior, mnditkne l locations, type WR hems M mmrmms, and star wd kcetipss. Gypsum board Installed where the Mud a lad spacing swede I V..c mall he W thl. pares Gypsum rand at garage ad under sere shall m 98' type X panel,. Use panois of the madmum land, possmle to son mae joint$. here( rig parMk won drywall screws of aperopr ate type, length and spacing Tape all Joints and apply drywall compound I, multiple sods fora uniform finish. Fire aping alone will only m allowed at concealed loom... Finish and texture coumpaund shall W .acted"the Owner antl shall have a un gam appearance readyfor panting. Where neoaseady, mumps layers d gypsum hoard may he but up to sohhe a required INokneM. If not. spaded at gypsum finish to W level 5. GYPSUM BOARD ACCESSORIES g u.nbond mreer mad number 103 O d Tyl lm s -sternal sorer , ndid of interior a bullring. Asap 401 a 402 gawanbea meal edge Dead fa al ayo,m gypeem bond ap-aaa edge mdddms. CERAMIC TILE Ceramic ere to he apprwad by Designer and Own.. AM shower am bemmb walk a he crowned to a height d 70• minimum above me dram inlet. and 4' beyond the lassie of me bathtub «shower pan. INTERIORCAUUMNG "ic Ishw, Were— grass, painted or in a mar Is mach adjacent finales ea rwtuietl. BUILDING SECTION VIEW NUMBER - - - - - -- -SHEET NUMBER --- -VIEWN MBER J� - - -- -SHEET NUMBER INTERIOR ELEVATION O` - - - - -- — - - VIM VIEW NUMBER 1�I UMBER 1 p 1—► -- - - - - -- KEYNOTE A0.0 COVER SHEET A0.1 SITE PLAN A3.0 ELEVATIONS A3.1 ELEVATIONS A3.2 ELEVATIONS A3.3 ELEVATIONS A4.0 ROOF PLAN WITH GLASS ENTRY A4.1 ISO VIEW & ELEVATION OF GLASS E ., $1N I Lrl,�'1',� CLJPERTINO 80ding Departrnent JUN 2 " 2013 p <EVi : iD } } ;ODE COMPLIANCE gv- W U Z W Vl Wr it Z O 2 U o Q V O LO 0) Q U O LZ r ❑ CL D U `W ❑ ,W,^ I.L V_J M Z D CD to CID O N � I p WI W >It OV two 2 SITE PLAN - EXISTING SITE PLAN PROPOSAL KEY NOTES 1❑ REPLANTED EXISTING PERSIMMON ❑P EXISTING PERSIMMON-REMAIN ONEW IEALPND FLAX OEXISITINGTREETOREMAIN ❑5 EXISTING PERSIMMON TO BE REPLANTED F.] EXISTING SOUTHERN MANGONLIATO BE REMOVED ❑j EXISTING HEDGE TO BE REMOVED ❑8 CLUMPING eAMB00 ❑B MONDO GRASS R. EXISTING SAUCER MAGNOLIA TO BE REMOVED 1T JAPANESEMAPLETOREMAIN ,2 REMOVE PERGOU CUPERTINO Building Department REVIEWED FOR CODE COMPLIANCE Reviewed By: ` -1911 47 -1 -// M_RUOP PLAN WITH THE PROPOSE GLASS ENTRY "4= ,, KEY NOTES Fl] .-.. ..1-N. -1 -OP. -M -. -.K.M GLASS EMRV -.R NEW SHINGLED ROOF. CUPERTINO q Building Department JUN 2 2013 REVIEWED FOR CODE COMPLIANCE Reviewed By e llA - W/ REVISIONS BY ' STRUCTURAL NOTES PT1116161fj C9�p �E) All material and workmanship hell conform with requirement of the 2010 edition of the P 4 Cw9d -10•G hll �r 7�LT'b C 1Cy110.0, � to'. �M Califomis Building Code. Verify all existing conditions and propose dimensions at job site prior to construction. See architectural drawings for dimensions and elevations not I Ld/ Z- �I$ °q� I iT.o ``� G�1 -Af2h Pip' `✓-A'1° shown. Safely Measures: At all times the contractor shall be solely and completely responsible GjUA"J'J Pbtd�.l_ f lA -p, for the conditions of the job site Including safety of the persons and property, and for all necessary Independent engineering reviews of these conditions. The Architect's or Wyyrtlrj Engineers job site review is not intended to include review of the adequacy of the ! Contractors safety measures. Provided shoring where required. Saone: C�) G...1• _9L. tDly —mat= I� -O" U1 Replace front entry canopy. _ _ _ _ — — — — _ W Design Livo Load: Roof: 20psf t � I ' � - ` ' � I c 'm C Floor. 40Psf I I• I I E Lumber • Headers - Douglas Fir No.1. 9'%� I"Ipl''• \ - o • Blockings - Douglas Fir No.2.) • All nailing shell be per Building Code Table 2304.9.1 except as noted otherwise. A'( O�EPI lal , II x !� I� 1":1 I t dU All connections not specifically detailed on the drawings shall be made with Simpson standard fasteners. I y,ug �I.{� I.,I /Ar�- 1YE ,t�j<SL- ll�f T �8 y t1 m fn N Structural Steel: Beams and plates shall be ASTM A36. Aik,�pbS 33/S I (�� $ jp� T 3. -:Q s1t2 PIp6 LOL. FE N WF OGhJ�jv o E -p ne G r p u Pipe column shell be ASTM A501. Ilk • Bolts shall be ASTM A307. CE) 51t� \jb}I1�C� I go • Welds shell be E70xx. ( m M W y E Eno": • Simpson SET or equal. DETAIL 2 DETAIL Special Inspection: Provide inspection per Chapter 17A for welding. (� 1 C�) UONU, t.1t1J� P„ElOhl - sib PPE Gnu - r�iu.7h 17ptl.i.�E}'Oj1'( IT � I INTO (! =)GA -1 U• =c� _ { i I '� kl°'f�= 5EE bl=u•}IT= •�T.IniL pr- bhhtJ�y _ - 'fYF — N °T °aiohlnl zh W. ��8 P�dt r.. Ikl! NoN- 5Np•Il -Ik - n W)7"+ alb. j=J HM 604, WoN Fes. r--AV CIT CUPERTINO Building Department 7k�e, III - T 3 ` s JUN 2 "' 2013 W)c �los r DETAIL DETAIL REVIEWEL FOR I "s I o' I zlLO„ ;0Q T-) poor a C Reviewed By,/� z v ROOF FRAMING PLAN >' W v z W = O WV rn C) cqd� wal L PP6 GoL. Z W LU ra Fr �_ W O z z �. - - - -- gz0D W - - -- — _T. i aoI� CE) (�p{bjEjEf• ART. Data (y_2>j_I'7 _.. Scale A,.� Drawn I' J+ Job I'J03?j sneer S1' Of Shnb FOUNDATION PLAN CAPER ENGINEERING INC. P.O BOX 14198, FREMONT, CA 94539 Tel: (510) 668 -1815 Fax: (510) 490 -8690 Project No. 8753 December 11, 2013 Building Department City of Cupertino 10300 Torre Ave. Cupertino, CA 95014 Subject: Chong Residence at 20668 Sunrise Dr. Cupertino, CA (Permit No. 13 060213) SPECIAL INSPECTION SERVICES FINAL AFFIDAVIT FOR STEEL WELDING FOR STEEL FRAME AT FRONT ENTRY CANOPY Dear Sir: CAPEX ENGINEERING 17VC., has provided testing and special inspection services at the subject site in accordance with section 1704A of the California Building Code (2010 Edition) as listed below: • Visually inspected . fillet welds on connection plate to steel channel and 3" square steel column to base plate using FCAW process with NR 232 wire by one qualified welder at front entry canopy Personnel under the general supervision of a registered Civil Engineer performed these inspections. Based on the inspections performed and upon our substantiate reports that the inspected work was performed, to the best of our knowledge, in conformance with the approved plans and specifications and the applicable workmanship provisions of the California Building Code. =- Sincerely,� CAPPEX E GINEERING INC., 1 q Gary su, Principal ' FILLf. . OF ,' Sincerely Bernard,F V No': 13033 ice bstitute the 3" diameter pipe column with 3" :olumn shall remain the same. F I L E" oFCSSIOn�A ML/AyC y�yct` Wyo. 2954 014 Exp�res63a sT rRU0 OF Cti`� V ,; ! ; Ki ��