Loading...
12050143 - SITESTING ENGINEERS, INC. 2811 Teagarden St. 510-835-3142 510-8343777 fax San Leandro, CA 94577 800-660-3142 San Leandro San Jose Martinez INSPECTION REPORT _ _ Week Ending: 9/28/12 PROJECT # 55674 PROJECT: Apple VG -1 Building 20650 Valley Green Drive Cupertino, CA Permit # 12050143; 12060046; 12020132; 12020131 DATE 9/25/12 HOURS 3 INSPECTOR M. Ardizzone TYPE OF INSPECTION: Concrete Placement PLACE OF INSPECTION: Jobsite Reported to Corky Hart of Devcon Construction at the jobsite as requested. Monitored loads arriving at the jobsite for correct mix and proper slump. Inspected placement operations and vibrating procedures. Performed 1 slump test (4") and cast 1 set of compression test specimens (5 each) Sample # 240804, for Concrete Mix # 3EFEG9Q1 from Central Concrete Supply Co. (specified strength 3000 psi, slump 4") for concrete placed at footing for CMU wall on line 1 from D to F. Total cubic yards placed: 5. Inspected the placement of reinforcing steel for the above. The preceding work was, to the best of my knowledge, in compliance with approved plans and specifications, including revisions by engineer. Reviewed by: David pero Special Inspection Division Manager 1cc: Apple Computer, Inc./J. Rickard Devcon Construction/ M. Brum Devcon Construction/S. Ramirez )2--wr SW Structural, Inc./S. Wade City of Cupertino/Bldg. Inspection Dept. This report can be reproduced only in its entirety unless written permission from TEI is obtained. Page 1 of 1 Testing Engineers, Inc. Quality Assurance Services Materials Consulting Since 1954 Regular Concrete Compression Test Report Project No.: 55674 Client: APP337 Project Name: Apple VG -1 Building, Phase 12 20650 Valley Green Drive Cupertino, CA Prmt #s 12020132;12020131;12050143 & Supplier: Central Concrete Mix: 3EFEG9Q1 Ticket No.: 18526671 Location: Footing for CMU wall at lines D -F @1. _, Sample No.: 240804 �d 10/23/12 10/23/12 Report Date : 10/23/12 HOLD ID Number Sample Date: 09/25/12 513 5C Time Sampled: 0835AM 5E Mark Sample Date Received :09/27/12 Inspector: M. Ardizzone, TEI Specimens Cast (ASTM C-31) : 5 Air Temperature (ASTM C-1064) : 58 deg F Mixture Temperature (ASTM C-1064) : 78 deg F Slump (ASTM C-143) : 4-1/2 inches Date Tested 10/02/12 10/23/12 10/23/12 10/23/12 HOLD ID Number 5A 513 5C 5D 5E Mark Sample Dimension, Inches Diameter 4 4 4 4 Length 8 8 8 8 Area, sq. inches 12.57 12.57 12.57 12.57 Ultimate Load, Ibs 36000 67000 68000 69000 Ultimate Str., psi 2860 5330 5410 5490 Average, Str., psi 5410 Age Tested, Days 7 28 28 28 HOLD Fracture Type 1 1 1 Dry Unit Weight, pcf Specified Strength, psi 3000 3000 3000 SPECIMENS NOT SCHEDULED FOR TESTING WILL BE DISCARDED AFTER 28 DAYS OLD The Material k_ WAS WAS NOT The Material Tested -4<— MET DID NOT MEET THE SAMPLED AND TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF THE BLDG. DEPT. OR DSA APPROVED DOCUMENTS. REQUIREMENTS OF THE BLDG. DEPT. OR DSA APPROVED DOCUMENTS. Remarks: Samples Tested in General Conformance with ASTM C-39 1 cc. City of Cupertino 1 cc. SW Structural, Inc. Reviewed By: 1 cc. Apple Computer Inc. j 1 cc. Devcon Construction 1 cc. Devcon Construction Robert (3reen W -f Concrete Lab Supervisor fi/ Corporate Office - 2811 Teagarden Street, San Leandro, California 94577 - (510) 835-3142 - Fax (510) 834-3777 LE TESTING ENGINEERS, INC. RECEIVED 2811 Teagarden St.510-835-3142 APR 2 2 2013 510-834-3777 fax San Leandro, CA 94577W�S;Idn- 800-660-3142 droSan Jose Martinez INSPECTION REPORT Week Ending: 3/22/13 PROJECT # 55674 PROJECT: 20650 Valley Green Dr. Cupertino, CA Permit # 12050143 DATE 3/16/13 (Saturday) HOURS 4 of INSPECTOR M. Ardizzone TYPE OF INSPECTION: Epoxied Dowels PLACE OF INSPECTION: Jobsite, Service Yard Reported to Corky of Devcon Construction at the jobsite as requested. Inspected predrilled holes for proper diameter and depth. Observed the cleaning of holes and the injection of Hilti Hit HY 150 MAX epoxy (exp. 8/13). Witnessed the proper insertion of four (4)1/2" diameter Allthread anchors, 9" in length, embedded 4" for dust collector at service yard. The preceding work was, to the best of my knowledge, in compliance with approved plans and specifications, including revisions by engineer. Reviewed by: 1cc: Apple Computer Inc./J. Rickard Devcon Construction/M. Brum Devcon Construction/S. Ramirez SW Structural, Inc./S. Wade City of Cupertino/Bldg. Inspection Dept. David Chippero Special Inspection Division Manager This report can be reproduced only in its entirety unless written permission from TEI is obtained. Page 1 of 1