11050221_==.KraZan & ASSOCIATES, INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION November 14, 2011 FILE KA Project No.: 04611102 Permit No.: 11050221 NorCal Communications and Construction 5130 Fulton Drive, Suite M Fairfield, California 94534 Attention: Ms. Kristi Raines Subject: Final Report - Special Inspection Services AT&T SNFCC A2037E, 10199 California Oak Way, Cupertino, California Ladies and gentlemen: As requested, Krazan & Associates, Inc. has provided Special Inspection services for the subject project. Our services, performed on November 4, 2011, consisted of observing the completed installation of post -installed anchor bolts in concrete and the performance of torque tests to confirm proper installation torque. The special inspection services provided were in accordance with the requirements of the City of Cupertino, as stipulated on the approved plans and in the California Building Code. A copy of our field report documenting our observations and test results is attached. CONCLUSIONS Based on the observations of our technician and the results of our tests conducted at the site, it is our professional opinion that the anchor bolts installed on November 4, 2011 were, to the best of our knowledge, installed in accordance with the approved project plans, the requirements of the California Building Code and the manufacturer's installation procedures. LIMITATIONS Construction inspection and testing (special inspection) services are techniques used to check construction for conformance with the project requirements as the work progresses and to reduce the potential that construction elements are not in compliance with the project requirements as the work is completed. Even with diligent construction monitoring, observation and/or testing some construction defects may be missed. Performance of construction observation and/or testing services (including but not limited to special inspection services) by Krazan & Associates' personnel is not insurance, nor does it guarantee construction of any type. In all cases, the contractor retains sole responsibility for the quality of work, for adhering to plans and specifications and for repairing defects, deficiencies or omissions, regardless of when they are found. 6711 Sierra Court, Suite B • Dublin, California 94568 • (925) 307-11600 Fax: (925) 307-1161 With Offices Serving The Western United States 04611102 Final Page No. 2 We have performed our services in a manner consistent with the standard of care and skill ordinarily exercised by firms of our type practicing under similar conditions at this same time and locality. However, we do not undertake the guarantee of construction or production of a completed project conforming to the project plans and specifications. No warranty or guarantee is expressed or implied. Our services during the identified period of time were limited to those documented in our attached report. If you have any questions regarding the information contained in this cover letter or the attached report, or if we can be of further assistance, please do not hesitate to contact our Dublin office at (925) 307-1160 for assistance. Attachments: daily field report (1 page) cc: Addressee City of Cupertino Respectfully submitted, KRAZAN & ASSOCIATES, �A Gregory J. Ruf, P.E. Managing Engineer Krazan & Associates, Inc. With Offices Serving The Western United States �pFESS/pNq G RY �Fy SGT 0 No.35389 Exp. 9-30-2013 \ CIVH. rFOF,C AL,F�� 04611102 Final =K aZai & Associates, Inc. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING AND INSPECTION DATE:k� PROJECT#: PROJECT: LOCATION: �z'1 1G7( �("Ir�J (,.ig ca_T ^j KRAZAN PROJECT MANAGER: ❑ HIGH STRENGTH BOLTS ❑ A Skidmoore test was performed on the lbs./ft. lbs./ft DSA File/Appl. OSHPD No. Permit No. P fff t�n-- CONTRACTOR: PERMIT NO: INSPECTOR: JURISDICTION: �1 ciy WEATHER: TEMP: ❑ A325 ❑ A490 _ -inch e) bolts with the following torque readings: lbs./ft. lbs./ft lbs./ft. Average torque reading: lbs./ft. tension. ❑ High strength bolt inspection was performed on the -inch 0 bolts at the following locationns: ❑ The bolts DID / DID NOT meet the required lbs./ft. tension. XI ANCHORS ❑ Prof LoadTorque Test D. oxy v *-i El /o of total -inch ❑ bolts were torque tested to ion at the following locations: ota anchors were o lbs./ft. tension at the following locations: ❑ Visual inspection was performed on Cx NOTES ❑ DISCREPANCIES ❑ % COMPLETE To the best of my knowledge, the above / WAS NOT performed in accordance with the approved plans, specifications, and regulatory requirements. Superintendent/Representative: Technician: 215 West Dakota Avenue, Clovis, CA 93612 • (559) 348-2200 4221 E. Brickell St., Ontario, CA 91761 • (909) 974-4400 2205 Coy Avenue, Bakersfield, CA 93307 • (661) 837-9200 43379 Business Park Dr., Ste. 300, Temecula, CA 92590 • (951) 694-0601 448 Mitchell Rd., Ste. C, Modesto, CA 95354 • (209) 572-2200 922 Valley Ave NW, Ste. 101, Puyallup, WA 98371 • (253) 939-2500 6711 Sierra Court. Ste. 8, Dublin, CA 94568 • (925) 307-1160 1230 Finn Hill Road NW, Ste. A, Poulsbo, WA 98370 • (360) 598-2126 5044 Bailey Loop, McClellan, CA 95652 • (916) 564-2200 11715 N. Creek Pkwy South, Ste. C106, Bothell, WA 98011 • (425) 485-5519 2979 W. Fairmount Avenue, Phoenix, AZ 85017 • (602) 265-7090 11616 E. Montgomery Dr., Ste. 31, Spokane Valley, WA 99206 • (509) 534-9711 FILE COPY