Loading...
Ordinance 1379 ORDIt~NCE NO. 1379 AN SCE OF 'li1E C1TY OF QJFERTIZIO AMF2iDING ~iAF'rER 16.16 OF THE C(TPERTIND Ii<JNICIPAL OODE BY ADOFITNG THE "NAT'IONAL F.rsrr~rCAI~ OODE", 1984 EDITION, AND THE IRdIF1DFdd OODE P14MSZONS FOR THE NATIONAL EIECIl2ICAL Off, 1984 F9I'lZOtd. '~ CITY OfXII1CII, OF THE CITY OF C{7PEE7PII~10 DOES OQtLtA'IIJ AS FULTAWS: CY:apter 16.16 of the Cttpextino l~tnicipal Oxle is hereby att~cled to read as follows: Section 16.16.010. Adoption of 1984 Nati t Rt E+r_r,-i rat rye The pmovisions of said National Electrical Ode an3 each and all of the regulatioa:s, provisions, oonditiorts and tenor of said Dods (thn~ ocpies oP which have been filed for use and examination by the public in the Office of the City Clerk) aril hereby referred to and hereby adopted, the same as if fully set forth in this Oniirtance, and are by stuff reference adopted and sections of this Ordinance. Section 16.16.020. Article 100 Amended -pep nitirn,a Article 100 is hereby amended by adding thereto the Following: A. Electrical Cantrac*~+ra• For the p~pOBe of this article, an Electrical 0.ntractor shall be a person holding a valid electrical contractor's license issued by the State of California. B. n Electrician• No person shall act in the capacity of Jotu»eymart Electrician, as herein defined, without a janrtayman electrician's certificate of ocmtpetency, issued by the Electrical Hoard oP F~mmitters, as provided in this section. C. ~ Electrician is an electrician qualified by training aryl experience to do the recurring work keep a facility in stuff ccetdition that it may be utilized at .its designated capacity and efficiency, to do repair work by zgplaoement or overhaul of axtstituertt parts or materials to laeep or restore a facility to a oandition uY equivalent to its original or design capacity or efficiency. -1- Section 16.16.030. Electrical Fee Schedu le. For issuing each permit ar additional permit $10.00 Light Fixtures - Incandescent 1-10 8.00 Itrarx]esoent aver 10 1.00 Each Other 2.00 Each Festoon ar Decorative Lighting 100 Lamps ar Iresa 10.00 101 to 200 IaagB 15.00 Over 2 2 Electrical Signs ~ or Gas Z]+pe 6.0 Switches ar Receptacles 1-10 8.00 over 10 1.00 Eac3i Appliances 4.00 Welding Outlet 5.00 Welder per K.V.E. 2.00 Heatirx3 Devices each K.W. 2.00 service Change 20.00 Panels up to zoo A~ lo.oo Panels over zoo to l,ooo Amp 20.00 Panels aver 1,000 A~ 35.00 control Panels 5.00 Temp. Meter 20.00 Temp. Pole 30.00 MOZURS: EACH 1/2 H.P or less _. 2 to 5 H.P. 5 to 15 H.P. 15 to 25 H.P. 25 to 50 H.P. 50 to 100 H.P. More than 100 Motor Generatar Set - 504 mare than transformers - each K.V.A. shall be caaLSidered as one harsepower (H.P.) Moved in Ha]se Fire Damage Trailer Space Special Inspection Special Circuits not herein listed Warlrn~anship ar Materials Air-~oooled ar oil-cooled lic~ti~g ar~d/ar pacer transformers -far each transformer - each K.V.A. shall be considered as one horsepower (1 H.P.) and 4 FL'B2 AS PER -2- 1.00 5.00 6.00 .8.00 10.00 15.00 30.00 35.00 35.00 35.00 10.00 60.00 10.00 15.00 For each MerYULy Arc Zatc~ aryl Equipment 2.00 For eac3i Range, Electric Clothes Dryer, ar Water Heater Installation 4.00 For each Oven ar Burnex Unit 4.00 Far each Welding Outlet 4.00 Gold Cathode Fixtures: 2G-o ~ 1.00 Funr 2.00 Gold Cathccie ISc~ting rnatrt t A}~~yq; Each 2rarLSformer per K.V.A. ar EYactlorr thereof 1.00 Section 16.16.040. r~~p atirx~ A. 'lYys language used in this Code, and the National Electrical Oode, which are made a part of this Oode by reference, is intended to convey tlse common and axepteci meaning familiar to the electrical i~nstty. B. ~e Building official ar his assistants is hereby authorized to determine the intent and meaning oP any pa~wisiarrs of this Code, Such determination shall be made in writing and a reoortii kept which revord shall be open to the public. Section 16.16.050. Am.rts and Additions to the 1984 Nati 7 Electrical Cade A. Article 110 is hereby amended by addiig thereto the followiig Article 110-23. 1. A~ll~ma[t~erials used inth~e ~ •+~*Ai i AticYr, alteratpia~rr~or repair cf shall be at least of the minimttin approved standards specified for all types of materials provided in this Ozdin~~nos. 2. Previous used material shall not be r+etnsed unless approved by the +~*m Official, prior to installatio¢r. 3. Certification letter (no powpsj. On all wank where no power is available, the person ar firm doing the work shall complete and sign a certification statement far test at time of final. electrical. See Ediibit ~~A". 4. IIectrical work shall be done only by: a. owner/occupant. b. Electrical coantractors who era in compliance with the Stets licensing laws. c. General Building Oontractar with anrrBntt B-1 license in o~rjunctian with building permit only. d. Maintenance Electrician. -3- 5. All electrical wiring shall be installed in approved raceway for all r.,iidirgs and structures, other than R1, R3, amt M fancies. - 6• a ~ vi~sib a area e~xept ignaling aid ballast type transforniezsible 7. All switches shall be located a miniaemi of 5ar install approved oP tub ar shower measured horizaitally G.F.I. 16.16.060 ~~'t~7F 310 AMA A. Notwit2:standincJ any other provisions of the National Electrical OOde. Section 310-15a is to bB sioe~7d~ed to z~ead: 310-15 AmpacltY• (a) Ampacities for oorductors rated 0-2000 volts shall be as ~anyi,aq notes. Effective6January ,1 1987ampacitiesth ar 310310-16 t1'~~1~ 310-30 eTd their' ~ao~anY~4 notes and figul,~. 'Zhe a~citY for Types V, AVA, AV8 aid AVL oordu~ctors rated 2001-5000 volts shall be the same as for those oozductor types rated 0-2000 volts. Zhe ampacities for soled dielectric in3ulated ccatdwctora ram 2001 to 35000 ~~ shall ~ ~ specified in Tables 310-69 through 310-84 and their aooa~anY~9 notes ro) svarTCla~T[(niS~ BY TABS ~~levels, ar thermal resistivities nat iix1~ in they tables shall be permitted to be calctllatsd, under ergineerirg supervisioci, by meads of the following genernl fozm:la: I = TC - (TA + C~IfPA~ RDC (1 + YC) RLA -4- I = Ampacity (for purposes of this formula). TCr = Corrhuctor temperature in degrees C. TAr =Ambient temperature in degrees C. DELII7i TD =Dielectric loss temperature rise. RDC = DC resistare of o~rductor at temperature RC. YC = Oa¢gx~ettt AC resistance resulting frro: skits effect aril pmoximity effect. RLA =Effective thermal resistance between ooariuctor and surzv:u:dirxg ambient. (FPN): 4he ampacities provided by this section are based err temperature along and do not take voltage drop into consideraticn. (FFN): Conductors of circuits as defined in Article 100, sized to prevent a voltage drop e~ooeeding 5 Percent, will provide reasonable efficiency of operation. Section 16.16.070. ~Y P regularly ~o5'ing are ar more Hill-time qualified electricians for the purpose of installaticar, alteration, mairrterrarrce ar repair ear any property which suc3r person owns ar oa~rpies, may designate a qualified electrician as a Maintenance Electrician. LJpoar being approved by the Chief Building Official, the Mairrtenanoe Electrician shall make moarttrly ar quarterly reports to the City covering all {netAllatio-tis, additions, ar alterations. All such work shall be installed and done in aooonjance with the provisions of the Electrical Oode, and shall be subject to the payment of fees, errs to inspectioar by the electrical inspector to the same extent as similar wank performed by other persons acrd for which such inspectiar is p~mvicled. Section 16.16.080. VIOZATIC7N - r!rv, au~rnFn Secticar 204 Any' Person, fizm, corporatiar, partTexship ar oo'PA,+„e,-~htp ~ willfully violates any of the provisions, ar fails to comply with any of the mandatory r+equit~emerrts of this Ordinance is guilty oP an infraction, and upon oonvictian thereof, shall be punishable as provided in Chapter 1.12 of the Cupertino Municipal Code, exioept that nothirrg herein coaitained shall be deemed to bar any legal, equitable, or summary remedy to which the City of Cupertino ar other political subdivision, ar arty person, firm, corpozation ar narr,,orct,tp may be otheawise entitled and the City of Cupertino or any other political subdivision ar person, firm, oorporaticn or ~rtns+,zhip may file a suit in the Superior Ootrrt of the County of Santa Clara, to restrain, ar enjoin any atteagrt~,ed ar proposed subdivision, or acts, in violation oP this Chapter. -5- at a regular' meetirr~ of the City uxu~cil of the " City Of tu~ert'im this S*h day Of Januarv ~ 1987 and F2~D-CPID at a zegular meeting of the City Ootu~cil of the City this ?nrh day of Januarv ~ 19871 by other following vote: Vow ww~,+t~+^e of the City Council AYFS: Gatto, Johnson, Rogers, Sparks NOES: None AASFNi': Plungy AHSTFrIN: None ATIESP: : ~%t~ MgyGr Ci Clerk qty of -6- ~~ (o-1) EXFIIBIT nAn cEE~ZFICA~'ION STATEtg?TP FCQ2 'g5P AT TIME OF FIt~-L ~~TCAL PFIIl~B.'P N0. ~TIIDING ADDRESS• DATE: I certify that within 30 days from the date of final electrical approval that a written signed statement shall be submitted by the electrical caittactor ~fio is in oompliaxe with the State lioensirg law ar the owner/ooa~pant~ that all electrical circuits have been tested far the following: 1. Gxwnriing oa~ctor oarstinuity. 2. Correct wiring polarity. 3. OverouL2~nt devices. 4. Appliances atri special equi~ent. 5. G.F.I. cirouits. Zhe test required above shall be reoozded and shall be made available aa~ z+equest frcm the Building Depaz'tment. 'lhe s+eooxded teat shall be signed and dated by the tester. Additimal testing mil' ~ Y an special installations. A detanninatias will be made at time of final inspection. Owner's Signature Cbattractor's Signature owner's Address Contractor's License N~nmber Oontiactar's Address ~m>zres EoR Ara~ns Arm A~oxs zoo z~ 1984 rIATZCrtAI, Er~strCAL OOI~E Section 16.16.010 Provides pirooedusrs for adaptioai of National Electrical Code. Section 16.16.020 Defiifes electrical 00[rt13CtAr~ jOl1Y'I18yIIiST1 electrician or mairrtenalY7a electrician. Section 16.16.030 Ci~anges fee schedule to be ocagarable with surraardirg jurisdictions. Section 16.16.040 specifies that language used in this Code to be oaigatible with the industry arri the Euildirg Official to determine meaning and intent. Section 16.16.050 Adds additional requirements to the Code that Clarifies materials, certification Of inspections, to whom permits Can be issued, wiring in oc~ez~ci ~+~ and iixiustrial buildings, transformer locations and protection of switches near tubs aryl showers. Section 16.16.060 Amends Section 310-15 Ampacity far conductors. 4he urnrsually hick perCerrtage of electronic o~guter data pmocessing equipmer-t within the City of Cupertino warrants a *++?~ +~ *+~+e*+* to limit sagacity of oorxructors to existing ~a:xL~a. Section 16.16.080 Amends Section 204 of the National Electrical Cade by broadening the requirements of violations aril penalties. IIECTODL~ (0-1)