.02 EXC-2007-09, TR-2007-04 Yates
..
CITY OF CUPERTINO
10300 Torre Avenue, Cupertino, California 95014
DEPARTMENT OF COMMUNITY DEVELOPMENT REPORT FORM
Application:
Applicant:
Property Owner:
Property Location:
EXC-2007-09; TR-2007-04
Kathy Yates
Kathy and Michael Yates
22292 Regnart Road
Agenda Date: August 14, 2008
Application Summary:
Hillside Exception to demolish an existing house and construct a new 5,188 square foot
residence with a 2,625 basement on slopes greater than 30% and to decrease the setback
of the second story downhill-facing wall plane.
Tree Removal request to remove two oak trees with 10" and 14" diameters.
RECOMMENDATION:
Staff recommends that the Planning Commission approve file no. EXC-2007-09 and TR-
2007..04 subject to the model resolution.
PROJECT DATA:
Existing Zoning District:
RHS-175 (Residential Hillside Zoning)
Proposed
Ordinance Allowed
Residence Square Footage:
1 st & 2nd Floors
Garage( semi-deta.ched)
Basement (not counted as sq. ft.)
5,188 sq.ft.
842 sq.ft.
2,625 sq.ft.
6,030 sq.ft.
6,500 sq.ft.
Setbacks:
Front
Sides
Rear
From Creek
92 feet
80 feet min.
40 feet
100 feet
1st Floor 2nd Floor
20 feet 25 feet
10 feet 15 feet
20 feet 25 feet
100 feet
Building Height:
Grading Quantity
26' 4"
641 cubic yards
30 feet
2,500 cubic yards
Environmental Review: Categorically Exempt, Class 32: infill development
2 - 1
EXC:-2001~9, ~-2007-04
August 14,2007
Page 2
BACKGROUND:
The subject lot is situated at the southern reaches of Regnart Canyon bordered on the
north by Regnart Road, to the east by Regnart Creek and lands of the Midpeninsula
Regional Open Space District, and to the south and west by other RHS-zoned
properties.. The existing residence is accessed via a lSD-foot long paved driveway from
Regnart Road. The residence occupies the most westerly bench of three benches on the
property that are separated from each other by a band of steeper slopes. From this
upper bench the property declines to the east toward Regnart Creek. The property is
not on a prominent ridgeline.
DISCUSSION:
Zoning Consistency
The proposed dwelling complies with the RHS zoning regulations with respect to most
setbacks, building height, square footage, and grading quantity (See Project Data).
Hillside exceptions are being requested for building features that do the meet zoning
regulations as discussed below. .
Exception for Developments on Slopes Greater Than 30%
The RHS- Hillside Ordinance prohibits any structures or improvements over 500 square
feet in area to occur on slopes greater than thirty percent unless an exception is granted.
The proposed house is largely located on the flat, upper bench; however, to the south, a
portion of the house, basement lightwell, outdoor. patio, and several stairwells encroach
on steeper (over 30% ) slopes. In addition, about half of the new leachfield lines are on
the steeper slopes. Cumulatively, the area of development on steeper slopes requires an
exception.
Exception for Setback of Second Story Downhill Facing Wall Plane
The RHS-Hillside Ordinance specifies that at least 75% of the second story downhill-
facing wall plane shall be setback an average of 7.5 feet and in no case less than 5 feet
from the first story Wall plane. The policy is intended to address highly visible arid
unarticulated wall masses facing downhill slopes. The northeastern (rear) building
elevation faces the primary downhill slope (Sheet A-5 of the plan set). Thirty~two feet
(45 %) of the second story wall plane has sufficient setback. The applicant has sought to
break-up the visual impact of the two-story tall wall plane by introducing a shed roof
above the kitchen wall and placing a redwood arbor over the eastern terrace.
Given the residence's placement in a less visible hillside location, staff feels this is an
acceptable solution that could be improved by continuing the shed roof across the two.
story wall plane. This design change is incorporated in the model resolution.
2-q
EXC-2007-09, TR-2007-04
,August 14, 2007
Page 3 '
Geological Review
The City Geologist, Cotton Shires Associates, has reviewed the geotechnical report
submitted by the project geologist, UPP Geotechnology, Inc., and concludes that the
project is geotechnically feasible (Exhibit A & B). The City Geologist recommended that
a grading and drainage plan be prepared and that isolated, saturated ground
conditions, observed during a site visit, be investigated.
A grading and drainage plan has been prepared and is in the plan set. It depicts the
location of the storm drain lines away from the septic leachfields. Staff walked the
property and found no saturated ground conditions. The applicant believes he
overwatered the lawn area, leading to the temporary, saturated conditions. The City
Geologist's recommendations are incorporated in the model resolution.
Tree Removal
. The project site is heavily wooded. The tree survey was p'repared by City Arborist,
David Babby using the new City tree ordinance, and was confined to that area
immediately in the vicinity of the proposed residence. In the project vicinity, 62 trees of
15 species were surveyed (Exhibit C). Of these trees, only nine are considered
"protected trees" - all of them Coast Live Oaks. Forty -four trees conflict with the
proposed house design and will require removal, only two of them are considered
protected trees: tree #23 (a 14" oak) and tree #18 (a 10" oak). The remainder slated for
removal are mainly Monterey Pines (24 trees), fruit and nut-bearing trees (5 trees), and
small diameter Douglas Firs (3 trees). The applicant states that he would like to retain
the oaks, but the fact is these oaks are located in the new leachfield area and the leach
lines cannot be setback 15 feet from the trunks as recommended by the City Arborist.
Staff is recommending removal and replacements of three 24" boxed native trees.
Submitted by: Colin Jung, Senior Planner ~
Approved by: Steve. Piasecki, Director of Community Developme~
Enclosures:
Model Resolution
Exhibit A: Supplemental Geologic Review Letter by Cotton Shires & Associates,
dated July 2, 2007
Exhibit B: Geotechnical Investigation, New Single-Family Residence, Yates Property,
22292 Regnart Road, Cupertino, California, prepared by Upp
Geotechnology; Inc. and dated March 11, 2004.
2-3] .
EXC-2007-09, TR-2007-04
August 14, 2007
Page 4
Exhibit C: A Tree Inventory and Review of the " Proposed Development at 22292
Regnart Road, Cupertino, California, prepared by Arbor Resources and
dated June 22, 2007.
Plan Set
G: \Planning\PDREPORT\pcEXCreports\2007excreports\EXC-2007-09.doc
2 -44
. .
EXC-2007 -09
CITY OF CUPERTINO
10300 Torre Avenue
Cupertino, California 95014
RESOLUTION NO.
. OF THE PLANNING COMMISSION OF THE CITY OF CUPERTINO
APPROVING A HILLSIDE EXCEPTION FOR A NEW 6,030 SQUARE FOOT
RESIDENCE ON SLOPES GREATER THAN 30% AND EXCEPTION TO THE
SETBACK OF THE SECOND-STORY, DOWNHILL-F ACING WALL PLANE AT.
22292 REGNART ROAD.
SECTION I: PROTECT DESCRIPTION
Application No.:
Applicant:
Location:
EXC-2007-09
Kathy Yates
22292 Regnart Road
SECTION II: FINDINGS FOR EXCEPTION
WHEREAS, the Planning Commission of the City of Cupertino received an application
for a Hillside Exception, as described on Section II of this Resolution; and
WHEREAS, the necessary notices have been given in accordance with the Procedural
Ordinance of-the City of Cupertino, and the Planning Commission has held one or more
Public Hearings on this matter; and
WHEREAS, the applicant has met the burden of proof required to support this
application, and has satisfied the following requirements:
1. The proposed development will not be mJunous to . property or
improvements in the area nor be detrimental to the public health and safety.
2. The proposed development will not create a hazardous condition for
pedestrian or vehicular traffic.
3. The proposed development has legal access to public streets and public
serVices are available to serve the development.
4. The proposed development requires an exception which involves the least
modification of, or deviation from, the development regulations prescribed in
this chapter necessary to accomplish a reasonable use of the parcel because
the residence is not visible from City established vantage points, the house
design as revised minimizes any negative visual impacts.
5. All al~ernative locatioriS for development on the parcel have been considered
and have b~en found to. create greater environmental impacts than the
location of the proposed development.
6. The proposed development does not consist of structures on or near known
ge'ological or environmental hazards that have been determined by expert
testimony to be unsafe or hazardous to structures or persons residing the:reiti.
Resolution No.
Page 2
EXC-2007 -09
August 14, 2007
7. The proposed development includes grading and drainage plans that will
ensure that erosion and scarring of the hillsides caused by necessary
construction of the housing site and improvements will be minimized.
8. The proposed development consists of structures incorporating designs,
colors, materials, and outdoor lighting which blend with the natural hillside
~nvironment and which are designed in such a manner as to reduce the
effective visible mass, including building height, as much as possibie without
creating other negative environmental impacts.
9., The proposed development is located on the parcel as far as possible from
public open space preserves or parks (if visible therefrom), riparian corridors,
and wildlife habitats unless such location will create other, more negative
environmental impacts.
10. The proposed development is otherwise consistent with the City's General
Plan and with the purposes of this chapter as described in Section 19.40.010.
NOW, THEREFORE, BE IT RESOLVED:
That after careful consideration of maps, facts, exhibits, testimony and other evidence
submitted in this matter, application no. EXC-2007-09 is hereby approved; and
That the subconclusions upon which the findings and conditions specified in this
Resolution are based and contained in the Public Hearing record concerning
Application EXC-2007-09, as set forth in the Minutes of the Planning Commission
Meeting of August 14,2008, and are incorporated by reference herein. '
SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY
DEVELOPMENT DEPT.
1. APPROVED EXHIBITS
Approval is based on the plan set titled: "Yates Residence, 22292 Regnart Road,
Cupertino, Calif." dated 7-07-07 and consisting of 11 sheets labeled Al through
A9, 1, and C2 and the material board, except as may be amended by this
resolution.
2. DESIGN REVISION
The shed roof on the rear eleyation shall be extended across the two-story wall to
the satisfaction of the Director of Community Development.
3. GEOTECHNICAL REVIEW
Prior to building permit approval, the applicant shall comply with the
recominendations outlined in the Cotton Shires & Associates, Inc.
Supplemental Geologic Review Letter dated July 2, 2007 and pertaining to the
proposed development.
2-62
Resolution No.
Page 3
EXC-2007-09
August 14,2007
4. NOTICE OF FEES, DEDICATIONS, RESERVATIONS OR OTHER EXACTIONS
The Conditions of Project Approval set forth herein may include certain fees,
dedication requirements, reservation requirements, and other exactions.
Pursuant to Government Code Se<;:tion 66020 ( d) (1), these Conditions constitute
written notice of a statement of the amount of such fees, and a description of the
dedications, reservations, and other exactions. You are hereby further notified
that the 90-day approval period in which you may protest these fees, dedications,
reservations, and other exactions, pursuant to Government Code Section
66020(a), has begun. If you fail to file a protest within this 90-day period
complying with all of the requirements of Section 66020, you will be legally
barred from later challenging such exactions.
5. TREE PROTECTION & REPLACEMENT
Prior to building permit approval, the applicant shall comply with the
recomme,ndations stated in the Arbor Resources report, dated June 22, 2007, for
the trees slated for retention.
The two, specimen-size Coast Live Oak trees approved for removal shall be
replaced with three 24" box native trees. Exact locations to be approved by the
Director of Community Development.
SECTION IV: CONDITIONS ADMINISTERED BY TIlE PUBLIC WORKS
DEPARTMENT
6. STREET WIDENING
Street widening, improvements and dedications shall be provided in accordance
with.City Standards and specifications and as required by the City Engineer.
7. CURB AND GUTTER IMPROVEMENTS
Curbs and gutters, sidewalks and relafed structures shall be installed in
accordance with grades and standards as specified by the City Engineer.
8. STREET LIGHTING INSTALLATION
. Street lighting shall be installed and shall be as approved by the City Engineer.
Lighting fixtures shall be positioned so as to preclude glare and other forms of
visual inferference to adjoining properties,. and 'shall be no higher than the
maximum height permitted by the zone in which the site is located. .
9. TRAFFIC SIGNS
Traffic control signs shall be placed at locations specified by the City.
2-~
Resolution No.
Page 4
EXC-2007-09
August 14, 2007
10. STREET TREES
Street trees shall be planted within the Public Right of Way and shall be of a type
approved by the City in accordance with Ordinance No. 125.
11. GRADING
Grading shall be as approved and required by the City Engineer in accordance
with Chapter 16.08 of the Cupertino Municipal Code. 401. Certifications a,nd 404
permits maybe required. Please contact Army Corp of Engineers and/ or Regional
Water Quality Control Board as appropriate.
All new retaining wall work requires calculations and details included within
gr(iding plan set. All grading plans must include an erosion control plan.
If site grading (excluding the building envelope) exceeds 1000 cubic yards, then
the applicant must pursue a Supervised Grading Permit with the City as described
iri Cupertino Municipal Code 16.08.230.
12. DRAINAGE
Drainage shall be provided to the satisfaction of the City Engineer.
Pre and Post-development calculations must be provided to identify if storm
drain facilities need to be constructed or renovated.
13. FIRE PROTECTION
Fire sprinklers shall be installed in any new construction to the approval of the
City and Santa Clara County Fire Department
14. UNDERGROUND UTILITIES
The developer shall comply with the requirements of the Underground Utilities
Ordinance No. 331 and other related Ordinances and regulations of the City of
Cupertino, and shall coordinate with .affected utility providers for installation of
underground utility devices. Ordinance No~ 331 requires all overhead lines to be
underground whether the lines are new or existing. The developer shall submit
detailed plans showing utility underground provisions. Said plans shall be subject
to prior approval of the affected Utility provider and the City Engineer.
15. IMPROVEMENT AGREEMENT
The project developer shall enter into a development agreement with the City of
Cupertino providing for payment of fees, including but not limited to checking
and inspection fees, storm drain fees, park dedication fees and fees for
under grounding of utilities. Said agreement shall be executed prior to issuance of
construction permits.
2-~
Resolution No.
Page 5
EXC-2007-09
August 14, 2007
Fees:
a. Grading/ Retaining Wall Permit: Greater of $2,163.00 min. or 6% of Imp.
Cost
b. Development Maintenance Deposit $ 1,000.00
c. Storm Drainage Fee: $ 3,083.10
Bonds:
a'. On & Off-Site Improvements Bond: 100% Performance Bond
-The fees described above are imposed based upon the current fee schedule
adopted by the City Council. However, the fees imposed herein may be modified
at the time of recordation of a final map or issuance of a building permit in the
event of said change or changes, the fees changed at that time will reflect the then
current fee schedule.
16. BEST MANAGEMENT PRACTICES
Utilize Best Management Practices (BMP's), as required by the State Water
Resources Control Board, for construction activity, which disturbs soil.
PASSED AND ADOPTED this 14th day of August 2007, at a Regular Meeting of the
Planning Commissio~ of the City of Cupertino by the following roll call vote:
AYES:
NOES:
ABSTAIN:
ABSENT:
COMMISSIONERS:
COMMISSIONERS:
COMMISSIONERS:
COMMISSIONERS:
ATIEST:
APPROVED:
Steve Piasecki
Director of Community Development
Cary Chien, Vice' Chair
Cupertino Planning Commission
G: \ Planning \ PDREPORT\ RES \ EXC-2007-09res.doc
2-9,5
TR-2007-04
CITY OF CUPERTINO
10300 Torre Avenue
Cupertino, California 95014
RESOLUTION. NO.
. OF TIlE PLANNING COMMISSION OF TIlE CITY OF CUPERTINO
APPROVING A TREE REMOVAL PERMIT TO REMOVE TWO SPECIMEN SIZE
. COAST LIVE OAK TREES AT 22292 REGNART ROAD
SECTION I: FINDINGS
WHEREAS, the Planning Commission of the City of Cupertino received an application
for a Tree Removal, as described in.Section II of this Resolution; and
WHEREAS, the necessary public notices have been given in accordance with the
Procedural Ordinance of the City of Cupertino, and the Planning Commission has held
one or more public hearings on this matter; and
WHEREAS, the applicant has met the burden of proof required to support said
application; and has satisfied the following requirements:
1) The location of the trees restricts the economic enjoyment of the property by
severely limiting the use of property in a manner not typically experienced by
o'YlLers of similarly zoned and situated property.
NOW, THEREFORE, BE IT RESOLVED:
That after careful consideration of maps, facts, exhibits, testimony and other evidence
submitted in this matter, the application for Tree Removal is hereby approved, subject to
the conditions which are enumerated in tJUs Resolution beginning on Page 2 thereof; and
That the subconclusions upon which the findings and conditions specified in this
resolution are based and contained in the public hearing record concerning Application
TR-2007-04 as set forth in the Minutes of the Planning Commission Meeting of August
14, 2007, ~d are incorporated by reference as though fully set forth herein.
SECTION II: PROTECT DESCRIPTION
Application No.: TR-2007-04
Applicant: Kathy Yates .
Location: 22292 Regnart Road
2 -10
Resolution
Page 2
TR-2007-04
August 14, 2007
SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY
DEVELOPMENT DEPT.
1. TREE REMOVAL
The applicant is authorized to remove two coast live oak trees of 10" and 14" in
diameter and identified as trees nos. 18 and 23, respectively, in an arborist report
prepared by Arbor Resources for the subject development at 22292 Regnart
Road, and dated June 22, 2007.
2. TREE REPLACEMENT
To mitigate the loss of the subject oaks, the applicant shall plant three (3) 24" box
native trees. Specific planting locations are subject to the approval of the
. Director of Cpmmunity Development.
3. NOTICE OF FEES, DEDICATIONS, RESERVATIONS OR OTHER
EXACTIONS
The Conditions of Project . Approval set forth herein may include certain fees,
dedication requirements, reservation requirements, and other exactions.
Pursuant to Government Code Section 66020(d) (1), these Conditions constitute
written notice of a statement of the amount of such fees, and a description of the
dedications, reservations, and other exactions. You are hereby further notified
that the 90-day approval period in which you may protest these fees'. dedications,
reservations, and other exactions, pursuant to Government Code Section
66020 (a), has begun. If you fail to file a protest within this 90-day period
complying with all of the requirements of Section 66020, you will be legally
barred from later challenging such exactions.
PASSED AND ADOPTED this 14th day of August 2007, at a Regular Meeting of the
Planning Commission of the City of Cupertino, State of California, by the following roll
call vote: . .
AYES:
NOES:
ABSTAIN:
ABSENT:
ATTEST:
COMMISSIONERS:
COMMISSIONERS:
COMMISSIONERS:
COMMISSIONERS:
APPROVED:
Steve Piasecki
Director of Community Development
G:\Planning\PDREPOR1\RES\2007\TR-2007 -04 res. doc
Cary Chien, Vice Chair
Planning Commission
2 - 11
~ COTTON, SHIRES & ASSOCIATES, INC.
alii CONSULTING ENGINEERS AND GEOLOGISTS
Exhibit A
July 2, 2007
C0044A
TO:
ColinJung
Planning Department
CITY OF CUPERTINO
10300 Torre Avenue
Cupertino~ California 95014
SUBJECT:
RE:
Supplemental Geologic Review
Yates, Proposed Residence
22292 Regnart Road
At your request, we have completed a supplemental geologic review of the
permit application for a new residence using the following documents:
. Septic System Design (1 sheet, 20-scale), prepared by Armand Louie, REHS,
dated March 14, 2007; and
. Architectural Plans, in~iuding: Site, Floor, BI1d, Basement P~ans, Sections and
Elevations (9 sheets, '16- and 4-scales), prepared'by Robert Avlles Design,
dated April 7, 2007. . .
Documents Previously Submitted for Our Review:
. Geotechnical Investigation (report), prepared by Upp Geotechnology, Inc.,
dated March 11, 2004;
. Architectural Plans, including: Site, Floor, and Basement Plans, and
Elevations (7 sheets, 16- and 4-scales), prepared hy Robert Aviles Design,
undated; and
. Topographic Map (1 sheet, 16-scale), prepared by Ward Surveying, dated
February 21, 2002.
In addition to evaluation of the above referenced documents, we have reviewed
pertinent technical dOctiinents from our office' files 'and p~rfornied a recent site
inspection. . ...' . , ..
N orthem California Office
330 Village Lane
Los Gatos, CA 95030-7218
(408) 354-5542 · Fax (408) 354-1852
e-mail: losgatos@cottonshires.com
www.cottonshires.com
Central California Office
. 6417 DOgtoWIl Road
Sant.u~, CA 95249-9640
(209) 736-4252 · Fax (209) 736-1212
e-mail: cottonshfres@starband.net
ColinJung
Page 2
July 2, 2007
C0044A
DISCUSSION
It is our understanding that the applicant proposes to demolish the existing
residential structure and construct a new residence in approximately the same general
vicinity as the existing residence. The new developm~t is to include a basement level,
ground level, second story, and detached garage. Access to the new development will
be via the existing driveway alignment.
In our previous review report, dated April 22, 2004, we concluded that the
project appeared feasible; however, it was unclear at the time how much grading would
be performed or the method of septic discharge. We recommended that a grading and
drainage plan be developed and that the method of septic discharge be specified, and
that architectural and structural plans be developed that include the recommendations
of the Project Geotechnical Engineer.
CONCLUSIONS AND RECOMMENDED ACTION
The proposed development is potentially constrained by steep slopes, expansive
surficial soil materials, surficial soil creep and shallow landsliding, shallow
groundwater, non-engineered fill with the potential for settlement and creep, and the
susceptibility of the site to very strong seismic ground shaking. The Project
Geotechnical Consultant has performed a geotechnical investigation at the project site
and provided design criteria that, in general, appear appropriate for the site conditions.
These recommendations include founding the residence and retaining walls on a pier
and grade beam foundation system with minimum 16-inch diameter piers embedded a
minimum of 8 feet into bedrock. Foundation recommendations also include
incorporating a foundation subdrain and constructing the foundation grade beam with
a 3-inch void (beneath the beam). Recommendations have been provided that include
removing all non-engineered fill in the vicinity of newly proposed structures and
replacing these materials with engineered fill.
The submitted documents do not include a Grading and Drainage Plan, as
recommended in our April 22, 2004 letter, A Septic System Design Plan has been
su bmitted that includes the proposed septic system layout. A new leachfield appears to
be proposed for the first graded bench below the proposed residence. Duririg our recent
site reconnaissance, we noted saturated ground conditions on this graded pad, near SP1,'
The Project Geotechncial Consultant should evaluate this area and determine the source
of the water and ramifications on septic leachfield performance.
We do not have geotechnical objections to the basic proposed development
concepti however, a detailed grading and drainage plan has not been submitted. Due to
shallow groundwater, the proximity to Regnart Creek, and the septic system layout, a
detailed drainage plan should be developed illustrating how surface watet will be
directed away from the septic leachfields. We recommend that the following items be
satisfactorily addressed prior to issuance of construction permits:
2 -13
COTTON, SHIRES & ASSOCIATES, INC.
ColinJung
Page 3
July 2, 2007
C0044A
1. Grading and Drainage Plan - A grading and drainage plan should be
submitted that depicts all proposed excavation and fill areas. Grading
quantities should be provided. All surface and subsurface drainage
pathways and discharge points should be identified.
2. Development Plans - Structural and Architectural Plans should be
generated that include the recommendations of the Project Geotechnical
Engineer.
3. Geotechnical Report Update and Plan Review - The applicant's geotechnical
consultant should review and approve all geotechnical aspects of the
development plans (i.e., site preparation and grading, site drainage
imptovements and design pararneters for foundations and retaining walls) to
ensure. that their recommendations have been properly incorporated. Since
approximately 3 years has elapsed since the Geotechnical Report was
generated, the consultant should provide an update of theil' original
investigation, as necessary.
. The Project Geotechnical Consultant should evaluate the saturated bench
area and determine the source of the water and ramifications on future
septic leacbfield performance.
. Geotec1Ulical recommendations have been provided that indicated that
materials excavated from the site can be re-used for engineered fill.
However, the surficial soils at the site have,been shown to be potentially
expansive. Consequently, the Project Geotechnical Consultant should
consider providing recommendations that include removing the potential
expansive soils from tlle building si~, or effectively mixing these soils
with non-expansive materials. The' geotedUlical consultant should be
onsite during the grading operations.
The results of the Geotechnical Plan Review should be summarized in a letter
and submitted to the City for review by. the City Engineer. The following
item should be performed prior to final project approval:
4. Geotechnical Field Inspection - The geotechnical consultant should inspect,
test (as needed), and approve all geotechnical aspects of the project
construction. The inspections should include, but not necessarily be limited
to: site preparation and' grading, site surface and subsurface drainage
improvements and excavations for foundations and retaining walls prior to
the placement of steel and concrete.
2 -14
COTTON, SHIRES & ASSOCIATES, INC.
ColinJung
Page 4
July 2, 2007
C0044A
The results of these inspections and. the as-built conditions of the project
should be described by the geotechnical consultant in a letter and submitted
to the Town Engineer for.review prior to final project approval.
LIMITATIONS
This review has been performed to provide technical advice to assist the City
with discretionary permit decisions. Our serVices. have been limited to review of the
documents previously identified, and a: visual review of the property. Our opinions and
conclusions are made in accordance with generally accepted principles and practices of
the geotechiucal profession. This warranty is in lieu of all other warranties, either
expressed or implied.
Respectfully submitted,
COTION, SHIRES AND ASSOCIATES, INC.
CITYGEOLOGICC NSULTANT
{\
Jo M. Wallace
Principal Engineering Geologist
CEG 1923
Patrick O. Shires
Senior Principal Geotechnical Engineer
GE 770
POS:JMW:st
2 -15
COTTON, SHIRES & ASSOCIATES, INC.
I
I
I
I
I
I
I
I
I
I
I.
I
I
I
I
I
I
I
I
Exhibit B
GEOTECHNICAL INVESTIGATION
NEW SINGE-FAMILY RESIDENCE
YATES PROPERTY
22292 REGNART ROAD
CUPERTINO, CALIFORNIA
PREPARED FOR
MR. AND MRS. MICHAEL YATES
22292 REGNART ROAD
CUPERTIN~, CALIFORNIA
MARCH 11, 2004
This document is protected under Federal Copyright Law. Unauthorized use or copying of this document is strictly prohibited. See
"APPLICATION FOR AUTHORIZATION TO USE"located at the end of this document if use or copying is desired by anyone other than
the client(s) and for the project identified above.
... UPP GEOFECHNOLOGY, INC.
. Engineering Geology · Geotechnical Englneering
2 -16
I
I
I
I
I
I
I
I
I
'I
I
I
I
I
I
I
I
I
I
upp GEOTECHNOLOG~ INC.
Engineering Geology · Geotechnical ~nglnee'rlng
Mr. and Mrs. Michael Yates
22292 Regnart Road
Cupertino, CA 95014
March 11, 2004
Project No. 2711.1Rl
Serial No. 12114
SUBJECT: GEOTECHNICAL INVESTIGATION
NEW SINGLE-FAMILY RESIDENCE
YATES PROPERTY
22292 REGNART ROAD
CUPERTINO, CALIFORNIA
'Dear Mr. and Mrs. Yates:
As you requested, we have performed a geotechnical investigation for the construction of a new
single-family residence on your property located at 22292 Regnart Road in Cupertino, California.
The accompanying report presents the results of our investigation and testing, and our conclusions
and recommendations concerning the geotechnical engineering aspects of the project. The fmdings
and recommendations presented in this report are contfugent upon our -review of the final grading,
foundation and drainage control plans and our observation of the grading and the installation of the
foundation and drainage control systems.
CRH/RRU:jc
Copies: Addressees (5)
750 Camden Avenue. Suite A · Campbell. CA 95008
(408' 866-5436 · FAX: (408' 866.9436
2 -17
I
I
I
I
I
I
"I
I
I
I
I
I
I
I
I
I
I"
I
I
INTRODUCTION
Th~s report presents the results of our geotechnical investigation for the construction of a new
single-family residence on the Yates property located at 22292 Regnart Road in Cupertino,
California (see Figure 1, Site Location Map). The purpose of our investigation was to explore the
soil and geologic conditions on the subject property and to'develop findings and recommendations
for the earthwork and foundation engineering aspects of the proposed development.
We understand that you are planning to raze the existing one- and two-story home, and construct a
new two-story residence with a partial basement in approximately the same location on the property.
We also understand that you are planning to construct a new, detached three-car garage.
SCOPE OF SERVICES
Our scope of services for this investigation included a review of geologic literature and aerial
. photographs of the site vicinity; engineering geologic reconnaissances and mapping; preparation of
two slope profiles; subsurface exploration; field and laboratory testing; geotechnical engineering
analyses of collected data; and the preparation of this report. This report has been prepared as a
product of our service for the exclusive use of Mr. and Mrs. Michael Y ate~ for the construction of
the proposed residence and garage. This report must not be used by other parties or for other .
purposes without prior written authorization from Upp Geotechnology, Inc. Tbis investigation has
been conducted in accordance with the scope and conditions presented in our proposal dated
December 5,2003. No other warranty, either expressed or implied, is made.
Copyright - Upp Geotechnology, Inc.
upp GEOTECHNOLOG'Y.. INC.
2 -18
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Yates - Geotechnical Investigation
March 11, 2004
Page 2 of 29
Because of possible future changes in site conditions or the standards of practice for geotechnical
e~gineering and engineering geology, the fmdings and recommendations of this report may not be
considered valid beyond three years from the report date, without review by Upp Geotechnology,
Inc. In addition, in the event that any changes in the nature or location of the proposed
improvements are planned, the conclusions and recommendations of this report may not be
considered valid unless such changes are reviewed, and the conclusions and recommendations
presented in this report are modified or verified in writing, by this firm.
METHOD OF INVESTIGATION
Geologic maps and aerial photographs were reviewed as part of our reconriaissance investigation to
evaluate, the prevailing geologic conditions on the site and in the vicinity. An initial site
reconnaissance was made by our project geologist on December 1, 2003. Subsequently, several
additional site visits were performed by our project geologist and staff engineer to conduct
additional engineering geologic mapping and prepare slope profiles using tape, compass, and band-
level techniques.
Subsurface conditions were investigated on January 16, 2004 by excavating four test borings using
both a truck-mounted drill rig and portable drilling equipment. The locations of the test borings are
shown on Figure 3, Partial Site Plan and Engineering Geologic Map. The boring locations were
approximately determined by measuring distance and bearing from mown points on the supplied
Copyright - Upp Geotechnology, Inc.
upp GEOTECHNOLOGy;. INC.
2 -19
..I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Yates - Geotechnical Investigation
March 11, 2004
Page 3 of 29
site plan and should be considered accurate only to the degree implied by the mapping technique
used.
The test borings were logged by our staff engineer in general accordance with the Unified Soil
Classification System described on Figure 6, Key to Logs. A Summary ofField Sampling
Procedures is presented on Figure 7. The boring logs. are presented on Figures 8 through 11. The
logs show our interpretation of the subsurface conditions at the locations and on the dates indicated
and it is not warranted that they are representative of the subsurface conditions at other locations
and times;
Soil samples obtained from the borings were retained for laboratory classification and testing. The
results bf moisture content, dry density, and shear strength tests are presented on the logs. The
results of the plasticity tests are presented on Figure 12, Plasticity Chart.
GEOLOGY AND SEISMICITY
Geolo~
The subject property is located along the east side of the central Santa Cruz Mountains, a northwest-
trending range within the <;alifomia Coast Ranges geomorphic province. According to the Geologic
Map of the Sargent-Berrocal fault zone between. Los Gatos and Los Altos Hills (Sorg~ D. H. and
McLaughlin, R. J., 1975), the site is in an area underlain at depth by Santa Clara Formation bedrock.
The Santa Clara Formation is generally described as Pliocene to Pleistocene age (approximately 5.3
Copyright - Upp Geotechnology. Inc.
upp GE'OTECHNOLOGY,. INC.
2 -20
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I'
I
Yates - Geotechnical Investigation
March 11, 2004
Page 4 of 29
million years old to 11,000 years old), yellowish-orange to reddish-brown, moderately consolidated
to well-consolidated stream deposits consisting of pebble and cobble gravels with lesser amounts of
sand, silt, and clay. The bedrock is overlain by slope debris (colluvial soil) on the subject property
and across most of the hillside areas in the site vicinity. Where the colluvial soil is located on
moderate to steep slopes, it is' subject to downhill creep, a process by which the soil moves
.
downslope at an imperceptibly slow rate as a result of gravity (see Figure 2, Local Geologic Map).
Seismicity
The greater San Francisco Bay Area is recognized by geologists and seismologists as one of the
most active seismic regions in the United States. The three major . faults that pass through the Bay
Area in a northwest direction have produced approximately 12 earthquakes per century strong
enough to cause structural damage. The faults causing such earthquakes are part of the San Andreas
falJlt system, a major rift in the earth's crust that extends for at least 700 miles along the California
Coast, which includes the San Aridreas, HaYward, and Calaveras fault zones.
The main trace of the active San Andreas fault is located approximately 2% southwest of the subject
property. The Hayward and Calaveras faults are located approximately 13~ and 17~ miles
northeast of the site, respectively. In addition, nearest trace of the potentially activ'e Monte Vista
Fault is located approximately % mile northeast of the subject site.
The Monte Vista Fault is characterized as a sinuous, southwest dipping thrust fault that, in this area,
h~s t~st older Monterey Formation bedrock above younger Santa Clara Formation bedrock and
Copyright - Upp Geotechnology, Inc.
2 - 21
upp GEOTECHNOLOG~ INC.
I
I
I
I
I
1
I
I
I
1
I
1
I
I
1
1
1
I
.1.
Yates - Geotechnical Investigation
March 11, 2004
Page 5 of 29
younger alluvium. According to the City's Geotechnical Hazards Map, the site is located in an F-I
zone. An F-I zone indicates that the site could experience strong ground sh~g and ground failure
(landsliding) during an earthquake along the Monte Vista Fault.
Based on analyses by the U.S. Geological Survey's Working Group on California Earthquake
Probabilities (2003), the San Francisco Peninsula segment of the San Andreas fault is estimated to
have a 21 % probability of producing an earthqu~e with a magnitude of 6.7 or greater by the year
2032. . The magnitude of an earthquake is a measure of the amount of energy released during a
seismic event, as determined by seismo'graphic measurements. The probability of at least one
magnitude 6.7 or greater earthquake on one of the active faults in the San Francisco Bay area by the
year 2032 is estimated to be 62%.
The intensity of an earthquake differs from the magnitude in that intensity is a measure of the effects
of an earthquake rather than a measure of the energy released. These effects can vary considerably
based on the earthquake magnitude, distance from the earthquakes epicenter, and site geology.
Because of the site's proximity to the San Andreas fault and the site geology, maximum anticipated
ground shaking intensities, given a large earthquake on the fault in the site vicinity, are
characterized as very ~trong and approximately equal to a Modified Mercalli intensity of VllI
(Borcherdt, et. al., 1975). A Modified Mercalli intensity ofVllI typically could cause slight damage
to specially designed earthquake-resistant structures, considerable damage in well built ordinary
Copyrlght- Upp Geotechnology, Inc.
upp GEOTECHNOLOG~ 'NC.
2 - 22
I
I
I
I
I
I
I
I.
I
I
I
I
I
I
I
I
I
I
I
Yates - Geotecbnimi.l Investigation
March 11, 2004 .
Page 6 of 29
structures, and partial collapse in poorly built or designed structures (Yanev, 1974) (see Table I,
Modified Mercalli Scale of Earthquake Intensities).
Aerial Photo!!ranh Review
Two sets of stereo graphic aerial photographs were reviewed to evaluate the historic site changes and
to aid in identifying faults and landslides. The first photograph set was taken in 1965 and the second
was taken in 1982. The 1965 photo shows that site grading was being performed at that time to
create the level pad for the existing residence. The 1982 photo shows the existing residence on the
building pad. In addition, it appears that Regnart Road was realigned at some time between the two
photographs.
We did not observe any evidence of faulting or photo-lineament on either set of photographs within
the subject property. In addition, no evidence of landsliding was observed in the imniediate site
. vicinity in either set of photographs.
SITE CONDITIONS
Site Descrintion
The irregularly shaped property is situated on a northeastern facing slope near the. base of a large
north-trending drainage on the eastern flank of the central Santa Cruz Mountains. The subject
property is bounded to the north by Regnart Road, to the south and east by open-space district, and
to the west by a private developed property.
Copyrighl- Upp Geotechnology, Inc.
upp GEOTECHNOLOG'Y, INC.
2 -23
I
I
I
I
I
I
I
I
I'
I
I
I
I
I
I
I
I
I
I
Yates - Geotechnical Investigation
March 11,2004
Page 7 of 29
A private shared driveway leads from Regnart Road along the northern property boundary to a short
private driveway that extends uphill to the south to the existing residence. The residence is a two-
story, wood framed structure located in the central portion of an existing cut-fill pad. A short
cutslope is located on the west (uphill) side of the driveway on the uphill side of the pad.
Grading to create the pad has resulted in a fill slope on the south and east sides of the pad. Based on
, our, observations, it appears that fill was also placed in the southwest portion of the pad to fill in a
natural drainage swale (see Figure 3). Gradients ofthe fill slope are approximately 2:1 (horizontal to
vertical). A chicken coup and pen are currently located in this area. A narrow path also constructed
using cut/fill' techniques leads from this southwest comer of the pad and trends southeast off the
property.
Below the fill slope is a cut slope with a gradient of approximately 2~: 1, located on the uphill side
of a second cut-fill pad. A similar fill slope is located on the downhill side of this pad. Again, it
appears that fill has been placed in the southwest comer of this second pad toinfill a portion of the
native drainage swale. :Two small sheds are located on this pad.
Drainage across the site is generally characterized as uncontrolled sheet flow to the east and
northeast to the property boundary. Vegetation 'on the 'site consists predominantly of mature pine
and oak trees with various, planted fruit trees and landscaping around the home.
Copyright - Upp Geotechnology, Inc.
2 - 24
upp GEOTECHNOLOGY,. INC.
I
I
I
I
I
I
I
I
I
I
I
I
I.
I
I
I
I
I
I
Yates - Geotechnical Investigation
March 11, 2004
Page 8 of 29
Subsurface
Four test borings were excavated on the existing cut-fill pad in the areas of the proposed residence
and garage, at the approximate locations shown on Figure 3. Boring 1 encountered approximately 4
feet of dark yellowish brown, clayey silt artificial fill underlain by approximately 3 feet of yellowish
brown clayey silt colluvium. Beneath the colluvium we encountered weathered sandstone and
siltstone bedrock of the Santa Clara Formation that persisted to the bottom of the boring at a depth
of approximately 16~ feet (see Figure 8, Log of Boring 1).
Boring 2 encountered approximately 3 feet of stiff, yellowish brown clayey silt colluvium underlain
by weathered, very dense sandstone and siltstone bedrock of the Santa Clara Formation. The Santa
Clara Formation materials persisted to the bottom of the boring at a depth of approximately 17 feet
(see Figure 9, Log of Boring 2).
Boring 3 encountered approximately 4 feet of dark yellowish brown, clayey silt artificial fill
underlain by approximately 5 feet of dark brown silty clay colluvium. The'colluvium is underlain by
very dense sandstone and siltstone bedrock that persisted to the bottom of the boring at a: depth of
approximately 16~ feet (see Figure 10, Log of Boring 3).
Boring 4 encountered approximately 2 ~ feet of dark brown silty clay colluvium underlain by dense
to very dense, weathered siltstone and sandstone bedrock of the Santa Clara Formation. These
materials persisted to the bottom of the boring at a depth of approximately 15~ feet (see Figure 11,
Log of Boring 4).
Copyright - Upp Geotechnology. Inc.
2 - 25
upp GEOTECHNOLOG~ INC.
I
I
'I
I
I
I
'I
I
I
I
I
I
I
I
I
I
I
I
I
Yates - Geotechnical Investigation
March 11, 2004
Page 9 of 29
Our interpretation of subsurface conditions is presented on Figures 4 and 5, Geologic Cross,.
Sections A-A' and B-B'.
Based on the results of a Plasticity Index test on a sample of the native colluvium, we determined
that these materials are moderately to highly expansive, with a Plasticity, Index (PI) of 31 % (see
Figure 12).
Groundwater
Stabilized free groundwater was encountered at a depth of approximatel}f 5Y2 feet in Boring 3.
Groundwater was not encountered in any of the other test borings. However, it should be noted that
fluctuations in the level of subsurface water could occur due to variations in rainfall, temperature,
and other factors not evident at the time our observations were made.
FINDINGS
Based upon the results of our investigation, it is our opinion, from a geotechnical engineering
perspective, that the proposed residence and garage may be constructed as planned, provided that
the recommendations presented in this report are incorporated into their design and construction. hi
our opinion, the primary constraints to the' proposed development include the thick layer of non-
supportive topsoil and artificial fill that mantle the property, and the proximity of the potentially
active Monte Vista fault and the active San Andreas fault.
Copyrighl- Upp Geotechnology, Inc.
2 - 26
upp GEOT.CHNOLOG~ INC.
I
I
I
I
I
I
I
I
I
I
I.
I
I
I
I
I
I
I
I
Yates - Geotechnical Investigation
March 11, 2004
Page 10 of 29
foundations of a proposed residence and associated improvements.
Landslidine:
Based on our investigation, we observed no evidence cif recent landsliding within the subject
property in the area of the proposed residence and garage.. However, as described above, large
Quaternary age landsli~e deposits are 'located north and west of the subject property. Based on the
location and geometry of these landslides, it is our opinion that these features do ~ot pose a
significant threat to the proposed residence and garage.
Because of the moderate slopes and the layer of non-supportive colluvial soil that blankets the
proposed building site, the occurrence of a new shallow landslide within or adjacent to the subject
property cannot be exCluded. A new shallow landslide in this area could be triggered by excessive
precipitation or strong ground shaking associated with an earthquake. In our opinion, a landslide of
this nature should not constitute an immediate threat to the integrity of the proposed residence and
associated improvements, provided that they are designed and constructed in accordance with the
recommendations of this report.
Copyright - Upp Geotechnology, [TIC.
2 - 27
upp GEOTECHNOLOGY,. INC.
I
I
I
I
I
I
I
I
I
I
I
'.1
I
I
I
I
I
I
I
Yates - Geotechnical Investigation
March 11, 2004
Page 11 of29
The long-term stability of many hillside areas is difficult to' predict. A hillside will remain stable
only as long as the existing slope equilibrium is not disturbed by natural processes. or by the acts of .
Man. Landslides can be activated by a nw:nber of natural processes, such as the loss of support at the
bottom of a slope by stream erosion or the reduction of soil strength by an increase in groundwater
level from ,excessive precipitation. Artificial processes caused by Man may include improper
grading activities; or the introduction of excess water through excessive irrigation, improperly
designed or constructed leacl;J.fields, or poorly controlled surface runoff.
It should be noted that although our knowledge of the causes and mechanisms of landslides has
greatly increased in recent years, it is not yet possible to predict with certainty exactly when and
where all landslides' will occur. At some time over the span of thousands of years, most hillsides
will experience landslide movement as mountains are reduced to plains. Therefore, a small, but
unknown, level of risk is always present to structures located in hilly terrain. Owners of property .
located in these areas must be aware of, and willing to accept, this unknown level of risk.
Seismicity
Our reconnaissance and our review of published geologic maps and aerial photographs revealed that
no known active or potentially' active faults pass through the subject property. However, it is
reasonable to assume. that the site will be subjected to very strong ground shaking from a major
earthquake on' at least one of the nearby active faults during the design-life of future improvements.
Copyright - Upp Geotechnology. Inc.
upp GEOTECHNOJ.OG~ INC..
2 - 28
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Yates - Geotechnical Investigation
March 11, 2004
Page 12 of29
During such an earthquake, it is our opinion that the danger from fault offset through the site is
negligible.
RECOM::MENDATIONS
The following recommendations must be incorporated into all aspects of future development:
Location of ProDosed Improvements
The proposed improvements must be confined to the approximate building area shown on Figure 3.
Construction of improvements outside of this generalized area is not recommended without written
approval from this fmn. In addition, if other structures are planned in the future, we should be
contacted to evaluate their location and to provide appropriate geotechnical engineering design
criteria.
Seismic Deshm Criteria
We recommend that the project structural design engineer provide appropriate seismic design
criteria for proposed foundations and associated improvements. The following information is
intended to aid the project stnJctural design engineer to this end and is based on criteria set forth in
Chapter 16 of the" 200 1 California Building Code (CBC) (futernational Conference of Building
Officials, 2002).
Copyrlghl- Upp Geotechnology, Inc.
2 - 29
upp GEOTECHNOLOGY,. INC.
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Yates - Geotechnical Investigation
March 11, 2004
Page 13 of 29
The subject property is located within Seismic Zone 4, as depicted in Figure 16A-2 of the 2001
CBC. Based on Table 16A-J and the defmitions presented in Section 1636A of the 2001 CBC, in
our opinion, Soil Profile Type Sc must be used for structural analyses. Based on Appendix A of the
. report, entitled "Probabilistic Seismic Hazard Assessment for the State of California" (CDMG and
USGS, 1996), and Table 16A-U of the 2001 CBC, the San Andreas fault is classified as a Seismic
Source Type A fault and is located approximately 4.4 Ian from the subjec~ property and the Monte
Vista Fault is classified as a Seismic Source Type B fault, and is located approximately 1.2 Ian from
the subject property. .
Experience has shown that earthquake-related distress to structures can be substantially mitigated by
quality construction. We recommend that the residence and ~sociated improvements be built by a
qualified and reputable contractor and skilled craftsmen. We also recox:nmend that the construction
be monitored by the project structural design engineer and project architect to make sure that their
designs and recommendations are properly interpreted and constructed.
Earthwork
We anticipate that a moderate amount of spoils will be generated from the excavations for the
residence foundation and basement, and that some or all of these spoils will be placed as engineered
fill on the slope behind the northeast comer of the proposed residence. We also recommend that any
. .
existing fill located in areas of proposed structures or flatwork be removed and replaced as
Copyrighr- Upp Geotechnology. Inc.
2 - 30
upp G.OTECHNOLO~ INC.
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Yates - Geotechnical Investigation
March 11, 2004
Page 14 of29
engineered fill. All engineered fill should be placed in accordance with the recommendations
provided below:
1. Clearini! and Site Preoaration
Any areas to be graded must initially be cleared of all obstructions, including brush, trees not
designated to remain, and debris remaining from the razing of the existing home. Holes or
depressions resulting from' the removal of underground obstructions below proposed finished
sub grade levels must be cleared,' and backfilled with suitable material compacted to the
requirements for engineered fill given below.
After clearing, the site must be stripped to a sufficient depth to remove all surface vegetation and
organic-laden topsoil. At the time of our field investigation, we estimated that a stripping depth of
approximately 3 to 4 inches would be required on natural slope areas. This material must not be
used as engineered fill;. however, it may be used for landscaping purposes.
2. Fill Material
On-site materials having an organic content of less than 3% byvolume can be used as engineered
fill. Material used for fill must not contain rocks or lumps greater than 6 inches in diameter, and no
more than 15% of the fill material must be larger than 2~ inches in diameter. Based on our
investigation, the subsurface materials. enco.untered in the borings are suitable for use as fill. Any'
required imported fill must have a plasticity index of 15% or less.
Copyright - Upp Geolechnology, Inc.
2 - 31
upp GEOTECHNOLOGy;. INC.
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Yates - Geotechnical Investigation
March 11, 2004
Page 15 of29
3. Kevwavs and Benches
Fill placed on slopes in excess of 5:1 must be keyed and benched into the underlying supportive
material to provide a firm, stable surface for support of the fill. A keyway, located at. the toe of
proposed fill, must be excavated a minimum of 3 feet into the supportive material, as measured on
the downhill side of the keyway. As a minimum, the keyway must be 8 feet wide at -its base.
Benches generally. must be a minimum of 8 feet wide and must be excavated entirely into the
supportive material. Based on our investigation, temporary- back slopes may be vertically excavated
provided they are constructed in the dry season and meet Cal OSHA requirements. Both the keyway
and any required benches must be provided with a 2% downslope in the uphill direction to provide
resistance to lateral movement and to facilitate proper subdrainage. The !!eotechnical enl!ineer
must evaluate the actual location. size and denth of the required keyway and benches at the
time of construction.
4. Subdrains
The need for sub drains' must be determined by the geotechnical engineer at the time of construction.
In general, fills exceeding 5 feet in depth should be provided with a subdrain. Subdrains must
consist of a 4-inch diameter rigid heavy-duty perforated pipe (Schedule 40, SDR 35 or equivalent),
approved by the Soil Engineer, embedded in drainrock (crushed rock or gravel). Flexible
corrul!'ated nine should not be used. The pipe must be placed with the perforations down on a 2-
Copyright - Upp Geotechnology, Inc.
2 - 32
UPP. GEOTECHNOLOG~ INC.
I
I
I
I
I
I
I
I
I
I.
I
I
I
I
I
I
I
I
I
Y ates- Geotechnical Investigation
. March 11, 2004
Page 16 of29
to 3-inch bed of drainrock. The drainrock must he separated from the fill and the native material by
a geotextile filter fabric, approved by the soil engineer
Subdrain pipes must be provided with clean-out risers at their up-gradient ends and at all sharp
changes in direction. Changes in pipe direction must be made with "sweep" elbows to facilitate
future inspection and cleanout. Subdrain systems must be provided with a minimum 2% gradient
and must discharge onto an energy dissipater at an appropriate downhill location approved by the
soil engineer.
5. Compaction Procedures
Prior to fill placement, the surface to receive the fill must be scarified to a depth of 6 inches,
moisture conditioned to approximately the materials' optimum moisture content and then compacted
as engineered fill. Fill material must be. moisture conditioned to approximately the materials'
optimum moisture content and then spread and compacted in lifts not exceeding 8 inches in loose
thickness. In general, fill should be compacted to at least 90% relative compaction by the Modified
Proctor Test method,' in general accordance with the ASTM Test Designation D1557 (latest
revision).
6. Permanent Slopes
Any proposed cut slopes in the surficial soil and any required fill slopes must have gradients no
steeper than 2: I (horizontal to vertical). Any proposed cuts in the bedrock may be steeper than 2: 1,
Copyright - Upp Geotechnology. Inc.
2 - 33
upp GEOTECHNOJ.OGY,. INC.
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Yates - Geotechnical Investigation
March 11, 2004
Page 17 of29
depending on the nature of the bedrock material. If cuts steeper than 2: 1 in the bedrock are planned,
we must evaluate the stability of these cuts during construction. If, based on our evaluation, these
bedrock cuts cannot support gradients in excess of 2: I, then retaining walls may be required.
All graded surfaces or areas of disturbed ground must be revegetated prior to the onset of the rainy
season following construction to prevent soil erosion. If vegetation is not established, other erosion
control provisions must be employed.. Ground cover vegetation, once established, must be properly.
maintained to provide long-term erosion control.
7. Trench Backfill
All utility trenches must be backfilled with compacted engineered fill. If on-site soil is used, the
material must be placed in lifts not exceeding 8 inches in uncompacted thickness, and must be
compacted to at least 90% relative compaction by mechanical means only. Imported sand may also
be used for backfilling trenches, if it is compacted to at least 90% relative compaction. Water jetting
to obtain the minimum degree of compaction in imported sand backfill is not permitted. fu all
pavement areas, the upper 6 inches of all trench backfill must be compacted to at least 95% relative
compaction.
Foundations
Because of the moder~tely. steep slopes and the presence of non-supportive artificial fill and
colluvium in the downhill portion of the building pad in the area of the garage and the rear/right side
Copyright - Upp Geotechn%gy. Inc.
2 - 34
upp GEOTECHNOLOGlr, 'NC.
I
I
I'
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Yates - Geotechnical Investigation
March 11, 2004
Page 18 of29
of the proposed residence, we recommend that the proposed residence and associated structures be
supported on drilled, cast-in-place, straight-shaft concrete friction piers gaining support in the
underlying bedrock.
1. Drilled Piers and Grade Beams
We recommend that drilled piers have a minimum diameter of 16-inches and be embedded a
minimum of 8 feet into the underlying bedrock or the depth equal to the thickness of non-
supportive overburden, whichever is greater. Support should be measured from the point where
there is a minimum of 5 feet of horizontal separation between the downhill face of the pier and the
surface of the bedrock. Total pier depth will vary across the building site depending on the depth of
the non-supportive soil and the extent of prior grading. Base4 on our subsurface investigation and
the currently proposed development concept, we anticipated p~er depths for the house of
approximately 8 feet to 16 feet below the proposed basement level and pier depths of between 14
and 22 feet in the area oIthe proposed garage.
The portion of the piers in the bedrock may be designed using a skin friction value of 400 psf for
dead plus live loads, with.a 1/3 increase for transient loads, including wind and seismic. Any portion
of the piers in the fill and non-supportive colluvial soil and any point-bearing resistance must be
neglected for support.
Active loads on the upper portion of the piers in the fill and non-supportive colluvial soil must be
figured on the basis of an equivalent fluid weight of 45 pcf taken over 2 pier diameters. The depth of
Copyright - Upp GeoteclmoJogy, ["c.
UPPG.OT.CHNOLOaY,IN~
2 - 35
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Yates - Geotechnical Investigation
March 11, 2004
Page 19 of29
the active loads will vary across the building site depending on the depth of the non-supportive
material. Where the surficial soil and fill is removed by grading or the basement excavation, active
loads 'will be negligible. However, where proposed structures are built at existing grades, active
loads may extend to depths of up to approximately 10 feet. To facilitate construction, it may be
appropriate for the structural engineer to prepare a table that provides pier depths and design based
on an active, ~one that could vary' from 0 to 11 feet.
,Lateral loads can be resisted using a passive pressure equal to an equivalent fluid weight of 350 pcf
to a maximum of 3,000 psf may be taken over 1 ~ pier diameters for the length of the piers in the
bedrock (below the plane at which there is a minimum of 5 feet horizontal separation between the
downhill face of the pier and the surface of the bedrock).
The bottoms of the pier excavations must be ,free of all loose cuttings and soil fall-in prior to the
installation of the reinforcing steel and the placement of the concrete. Any accumulated water in the
excavations should also be removed prior to the placement of the steel and concrete. If, because of
high groundwater, it is !lot possible to dewater the pier holes, the concrete may be placed underwater
by the Tremie method. In this case, the concrete must be placed'by a contractor experienced in the
tremie method.
Because of. high groundwater, the pier holes may be subject to partial collapse before pouring
concrete. We recommend that the concrete be poured as soon after drilling as practical. In addition,
Copyright - Upp Geotechnology, Inc.
2 - 36
upp GEOTECHNOLO~ INC.
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Yates - Geotechnical Investigation
March 11, 2004
Page 20 of 29
t~e contractor must be prepared to use other methods, such as removable casing, to keep the hole
open until the c~mcrete is poured.
Because the surficiai soil is moderately expansive, the pier holes must be kept moist prior to pouring
concrete to prevent the development of shrinkage cracks. fu addition, sono tubes must be used in the
. tops of the hole to prevent overpour (mushrooming) of the concrete.
The bedrock at the site has variable consistency and locally can be very hard. We recommend that a
high-powered well-maintained drill rig equipped with rock teeth be used to drill the holes. If drilling
refusal is met above the design depth, UOI and the structural design. engineer must be contacted to
revise the design !ecommendations. Hard cobbles or even small boulders may be encountered
during drilling. The contractor must plan for this condition in choosing the appropriate means and
methods of drillin&.
Because of the moderately expansive nature of the surficial soil, we recommend that a 3-inch void
be created below the grade beams over the soil.' During construction, the soil engineer should
determine where voids. are required. Degradable cardboard forms or other methods approved by the
soil engineer must be used to create the voids. Galvanized flashing or other non-degradable material
must be placed on each side of the void to ensure that it remains open for the life of the foundation.
Any concrete overpour must be removed before the concrete has achieved its design strength.
As a minimum, piers should be reinforced with a cage of four No.5 steel reinforcing bars, provided
full length. The actual number, size, location, depth, spacing, and reinforcement of the piers must be
Copyright - Upp Geotechnology, Inc.
2 - 37
upp GEOTECHNOLOGy;. INC.
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
. Yates - Geotechnical fuvestigation
March 11, 2004
Page 21 of29
determined by the structural design engineer based on the anticipated building loads and the soil
engineering design parameters provided above.
. To verify that the piers are founded in material of sufficient supporting capacity, are of sufficient
depth, and have been properly prepared, it is essential that we observe the Diers as thev are bein!!
drilled.
Grade beams must be reinforced with top and bottom reinforcement to provide structural continuity
and to permit the spanning of local irregularities. fu addition, good structural continuity must be
provided between the grade beam and the piers. The structural design engineer must determine the
actual size and reinforcement of the grade beams.
2. Retainin!! Walls
Basement and site retaining walls must be supported on foundations designed in accordance with
the recommendations given above for the support of the proposed residence. We recommend that
retaining walls be designed to resist both lateral earth pressures and any additional lateral loads
caused by surcharge loads on the adjoining ground surface. fu addition, we recommend that
retaining walls adjacent to living spaces be provided with appropriate waterproofing.
We recommend that unrestrained walls be designed to resist an equivalent fluid pressure of 45 pcf.
Restrained walls must be designed to resist an equivalent fluid pressure of 45 pcfphis an additional
uniform lateral pressure of 8 H psf, where H = height of backfill above the top of the wall footing in
Copyright - Upp Geotechnology. Inc.
2 - 38
UPPGEOTBCHNOLOG~'N~
I
I
.1
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Yates - Geotechnical Investigation
March 11, 2004
Page 22 of 29
feet. Wherever the walls will be subjected to surcharge loads, they must be designed for an
additional uniform lateral pressure equal to 1/2 or 1/3 the anticipated surcharge load for restrained
or unrestrained walls, respectively. In addition, walls with sloping backfill must be designed for an
additional 1 pcf for each 3 degrees of slope inclination.
The preceding pressures assume that sufficient drainage is provided behind the walls to prevent the
buildup of hydrostatic pressures from surface or subsurface water infiltration. Adequate drainage.
may be provided by means of a backdrain system consisting of an approximately I-foot thick curtain
of drainrock (crushed rock or gravel) placed behind the wall. The drainrock must be separated from
the backfill by a geotextile filter fabric, such as Mirafi 140 or.an alternate, approved by the soil
engineer. A 4-inch diameter heavy-duty rigid perforated subdrain pipe (Schedule 40, SDR 35 or
equivalent), approved by the soil engineer, must be placed with the perforations doWn on a 2- to 3-
inch layer of drainrock at tbe base of the drain. Where sub drain pipes will be buried at depth greater
than 10 feet, Schedule 80 or equivalent pipe must be used. Flexible corrul!:ated DiDe must not be
.~
Perforated retaining wall sub drain pipes must be dedicated pipes and must not connect to the surface
drain system. The sub drain pipes should be installed with a positive gradient of at least I % and must
be provided with clean-out risers at their up-gradient ends and at all sharp changes in direction.
Changes in pipe direction must be made with "sweep" elbows to facilitate future inspection and
cleanout. The perforated pipes must be connected to buried solid pipes to convey collected runoff to
Copyright - Upp Geolechnology, Inc.
2 - 39
upp GEOTECHNOLOGl';. INC.
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I.
I
Yates"": Geotechnical Investigation
March 11, 2004
Page 23 of 29
discharge onto an energy dissipater at an appropriate downhill location, approved by the
geotechnical engineer.
Backfill placed behind the walls must be compacted to at least 90% relative compaction, using light
compaction equipment, in accordance with the compaction procedures given above. If heavy
compaction equipment is used, the walls should be appropriately temporarily braced, as the situation
requires. If backfill consists entirely of drainrock, it should be placed in approximately 2-foot lifts
. .
and must be compacted with several passes of a vibratory plate compactor.
We recommend that annual maintenance of retaining wall backdrain systems be performed. This
maintenance must include inspection and flushing to make sure that sub drain pipes are free of debris
and are in good working order; and inspection of sub drain outfall locations to verify that introduced
water flows freely through the discharge pipes and that no excessive erosion has occurred. If erosion
is detected, we must be contacted to evaluate its extent and to provide mitigation recommen~ations,
if needed.
3. Concrete Slabs
It is anticipated that concrete slabs-on-grade may be used for the garage, basement, driveway, patios,
and walkways. We recommend that slabs-on-grade be supported on a min~um of 12 inches of non-
expansive fill compacted to 90% relative compaction to provide a uniform surface for slab support.
Prior to placement of the non-expansive fill, the sub grade must be scarified to a depth of 6 inches
Copyright - Upp GeotechlloTogy. Inc.
2 -40
upp GEOTECHNOLOGY, 'NC.
I
I
I
I
I
I
I
I
I
'I
I
I.
I
I
I
I
I
I
I
yates...... Geotechnical Investigation
March 11, 2004
Page 24 of 29
and compacted to 90% relative compaction. Prior to placement of reinforcing steel, the surface of
the non-expansive fill should be proof-rolled to provide a smooth firm surface for slab support.
In areas where floor wetness is undesirable, 4 inches of free-draining gravel must be placed beneath
the floor slab to serve as a capillary barrier between the sub grade soil and the slab. In order to
minimize vapor transmission, a heavy-duty, impermeable membrane must be placed over the gravel.
The membrane should be covered with 2 inches of sand to protect it during construction. The sand
should be lightly moistened just prior to the placement of the concrete. The gravel, moisture barrier,
and sand may be used in lieu of the upper 6 inches of recommended non-expansive fill. .
Slab reinforcement must be provided in accordance with anticipated use and loading; but, at a '
minimum, slabs must be reinforced with 6 inch by 6 inch 10/10 gauge. wire mesh tension
reinforcement sheets (not rolls) placed mid-height in the slab. We recommend that the reinforcing
be supported from below on concrete blocks (or similar) during concrete pouring to make sure that
it remains mid-height in the slab.
To help control cracking, concrete slabs should be grooved at 10-foot intervals or in accordance
with the structural engineers recommendations.
Draina!!e
Control of surface drainage is critical to the successful development of hillside properties. The
results of improperly controlled rurioff may include foundation beave and/or settlement, erosion,
Copyrighl- Upp Geotechnology. Inc.
upp GEOTECHNOLOGY,. INC.
2 - 41
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Yates - Geotechnical fuvestigation
March 11, 2004
Page 25 of 29
gullying, ponding, and potential slope instability. Surface water must be prevented from ponding in
pavement areas and adjacent to the foundation of the proposed residence and garage. Pavement
areas must be constructed for proper drainage by sloping them away from the resid~nce and by
providing area drains. To mitigate ponding water adjacent to the residence, we recommend that the
ground surface around the structure be provided with a positive gradient of at least 5% sloping away
from structure for a minimum distance of 5 feet or, as an alternative, area drains could be installed
. to collect surface runoff. We recommend that the proposed structure be provided with roof gutters
and downspouts. Water collected in the gutters must not be allowed to discharge freely onto the
ground surface adjacent to the foundation and must be conveyed away from the residence via buried
closed conduits or lined surfaces. Where downspouts are connected to buried pipes, they must be
provided with slip-joint connectors or cleanouts to facilitate maintenance.
Becau~e the house will be located on a cut/fill pad adjacent to a naturally occurring swale, there
exists a potential for groundwater to surface into any crawlspace beneath portions of the home that
extend beyond the limits of the basement. To mitigate this condition, we recommend that a
subsurface intercept (foundation) drain be installed along the upgradient sides of the house. We also
recommend that a similar foundation drain be installed along the upgradient sides of the detached
garage.
We recommend that the subdrain consist of a I-foot wide trench dug to a minimum depth of 2 feet
and filled with drainrock (crushed rock or gravel). A 3-inch diameter rigid heavy-duty pipe
Copyright- Upp Geatechnalogy. Inc.
2 - 42
upp GEOTECHNOLOG~ INC.
I'
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Yates - Geotechnical Investigation
March 11, 2004
Page 26 of 29
(Schedule 40,. SnR 35 or equivalent) .approved by the soil engineer, must be embedded in the
bottom of the drainrock (crushed rock or gravel). Flexible corrugated pipe must not be used. The
pipe must be placed with the perforations down on a.2- to 3-inch bed of drainrock. The drainrock
must be separated from the soil by a geotextile filter fabric, such as Mirafi 140 or alternate,
approved by the soil engineer. Where appropriate, the separate solid surface/downspout drainpipe
may be. placed in the upper part of the sub drain trench
Subsurface intercept drains must be provided with clean-out risers at their up-gradient ends and at
all sharp changes in direction. Changes in pipe direction must be made with "sweep" elbows to
facilitate future inspection and cleanout. Subdrain systems must be provided with a minimum 1 %
gradient and must discharge onto an energy dissipater at an appropriate downhill location approved
by the soil engineer.
While control of surface drainage and/or the ~ubsurface intercept drain should prevent water from
ponding in the crawlspace areas beneath structures, we also recommend that crawlspace areas be
. graded to slope to on~ or more low areas. These low areas must be provided with area drains to
collect any water that may accumulate in the crawlspace.
Concentrated surface runoff must not be allowed to flow over the top of any artificial slope. If
necessary, the ground surface at the top of the slope should be graded to slope away from the.slope;
or a berm or lined drainage ditch must be provided at the top of the slope. In addition, surface runoff
Copyright - Upp Geotechnology, Inc.
2- 43
upp GEOTECHNOLOG~ 'He.
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Yates - Geotechnical Investigation
March 11, 2004
Page 27 of 29
must not be allowed to pond adjacent to retaining walls. Lined drainage ditches should be provided
at the tops of retaining walls located at the base of descending slopes.
All collected water must be conveyed away from the residence via buried closed conduit or hard
surfaced drainage way and discharged onto an energy dissipater at an appropriate downslope
location approved by the soil engineer. Energy dissipaters may consist of an approximately 6-foot
long "T" fitting of perforated rigid pipe placed in a shallow trench and covered with a mound of
cobbles. Discharge must not .be located on or adjacent to steep~potentially unstable terrain.
We recommend that annual maintenance of the surface drainage systems be perfonned. This
maintenance must include inspection and testing to make sure that roof gutters and downspouts are
in good working order and do not leak; inspection and flushing of area drains to make sure that they
are free of debris and are in good working ord~r; and inspection of surface drainage outfall locations
to verify that introduced water flows freely through the discharge pipes and that no excessive
erosion has occurred. If erosion is detected, this office must be contacted to evaluate its extent and
to .provide mitigation recommendations, if needed.
PLAN REVIEW AND CONSTRUCTION MONITORING
We must be retained to review the final grading, foundation, and drainage control plans in order to
verify that our recommendations have been properly incorporated into the proposed project. WE
MUST BE GIVEN AT LEAST ONE WEEK TO REVIEW THE PLANS AND PREPARE A
PLAN REVIEW LETTER.
Copyrighl- Upp Geotechnology, Inc.
upp GEOTECHNOLOGY,. INC.
2 -44
I
I
I
I
I
I
I
I
I
I
I
I
I
.1
I
I
.1
I
I
Yates -. Geotechnical Investigation
March 11, 2004
Page 28 of 29
We also must be retained to observe the grading and the installation of foundations and drainage
systems in order to:
. Verify that the actual soil conditions are similar to those encountered in our
investigation
. Provide us with the opportunity to modify the foundation design, if variations
in conditions are encountered
'. Observe whether the recommendations of our report are. followed during
construction
Sufficient notification prior to the start of construction is essential in order to' allow for the
scheduling of personnel to insure proper monitoring. WE MUST BE NOTIFIED AT LEAST
TWO WEEKS PRIOR TO THE ANTICIPATED START-UP DATE. IN ADDITION. WE
MUST BE GIVEN AT LEAST TWO WORKING DAYS NOTICE PRIOR TO THE START
OF ANY ASPECTS OF CONSTRUCTION WHICH WE MUST OBSERVE.
The phases of construction to be observed by this firm must inclu.de, but are not necessarily limited
'to, the following:
1. EARTHWORK: During construction to observe keyway and bench.
excavations, to evaluate the need for subdrainage, and to test compaction of
engineered fill
2. DRILLED PIER EXCAVATION: During drilling to evaluate depth to
supp'ortive material and final pier depths
3. RETAINING WALL BACKDRAIN: During installation, if retaining walls
are planned
Copyright - Upp Geotechnology, Inc.
upp GEOTECHNOLOG~ INC.
2 -45
I
.1
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Yates - Geotechnical Investigation
March 11, 2004
Page 29 of 29
4. RETAINING WALL BACKFILL: During backfill to observe and test
compaction, if retaining walls are planned
5. SLABS-ON-GRADE: Prior to and during placement of non-expansive fill to
observe the sub grade preparation and to test compaction ofnon..expansive fill
6. SURFACE DRAINAGE SYSTEMS: Near completion to evaluate
installation and discharge locations.
*********
A Bibliography, a List of Aerial Photographs, and the following Figures arid Table are attached and
complete this report:
FIGURE NO.
SITE LOCATION MAP...... ..... ............ ...... ....... ............... ............. .... ..~.. 1
LOCAL GEOLOGIC MAP .................................................................... 2
PARTIAL SITE PLAN AND ENGINEERING GEOLOGIC MAP ...... 3
GEOLOGIC CROSS-SECTION A-A' ................................................... 4
GEOLOGIC CROSS-SECTION B-B'...............;.................................... 5
KEY TO LOGS.... ..................... .......... .......... ................ .............. ........... 6
SUMMARY OF FIELD SAMPLING PROCEDURES ......................... 7
LOGS OF BORINGS 1 THROUGH 4................................................... 8 - 11
PLASTICITY CHART............. ................ ................ ................. ............. 12
TABLE NO.
MODIFIED MERCALLI SCALE OF EARTHQUAKE INTENSITIES I
.Copyright - Upp Geotechnology, Inc.
2 -46
upp aEOTECHNOLOGY,. INC.
I
I
.1.-
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
BffiLIOGRAPHY
BORCHERDT, R. D., J. F. GffiBS, and K. R. LAJOIE, 1975, Mans Showinl!
Maximum Earthquake Intensity Predicted in the Southern. San Francisco Bay
Region. California. for Large Earthquakes on the San Andreas and Hayward Faults,
U.S. Geological Survey, Miscellaneous Field Studies Map MF-709.
CITY OF CUPERTINO, 1977, Geologic and Seismic Hazards Map, 1:12,000.
INTERNATIONAL CONFERENCE OF BUll,DING OFFICIALS, 2002, -2001
California Building Code, California Code of Regulations, Title 24, Part 2 (Volume
2), lCBO, Whittier, CalifornIa. .
ROGERS, T. H. and J. W. WILLIAMS, 1974, Potential Seismic Hazards in Santa Clara
County. California, California Division of Mines and Geology, Special Report 107,
39 p., 6 plates.
SORG, D. H., and R. J. MCLAUGHLIN, 1975, Geologic Map of the Sar~ent.Berrocal
Fault Zone between Los Gatos and Los Altos Hills. Santa Clara County. California,
U.S. Geological Survey Miscellaneous Field Studies Map MF-643, 1 :62,500.
U.S. GEOLOGICAL SURVEY, 2003, Understanding Earthauake Hazards in the San
Francisco Bay Region, U.S. Geological Surve)kFact. Sheet 039-03.
WORKING GROUP ON CALIFORNIA EARTHQUAKES, 2003, Understanding
Earthquake Hazards in the San Francisco Bay Region, U.S. Geological Survey Fact
Sheet-039-03~
Y ANEV, P., 1974, Peace of Mind in Earthquake Country: Chronicle Books, San
Francisco, California.
LIST OF AERIAL PHOTOGRAPHS
"BAY AREA TRANSPORTATION STUDY", black and white, dated May 14,1965, at
a scale of 1" = 1,000', Aerial Survey Contract No. 67615, Serial Nos. SCL 5-100
and 5-101, State of California Highway Transportation Agency, Division of
Highways.
upp GI!OT.CHNOLOG~ INC.
2 -47
I
I
I
I
I
I
I
I
I
I
I
I
I.
I
I
I
I
I
I
D.S.GEOLOGICAL SURVEY, black and white, dated January 8, 1982, at a scale of
1 :20,000, Serial Nos. JSC 7-22 and 7-23.
upp GEOT.CHNOLO~ INC.
2 -48
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Base: USGS Topographic Map; HORIZONS TECHNOLOGY, INC.; 1997
SITE LOCATION MAP
UPPGEOTECHNO~G~IN~
YATES PROPERTY
22292 Regnart Road
Cupertino, California
f;n9'"~nng Gt'CNogy. C..eorf'CflnltaJ ~nt'Cnng
APPROVED BY
SCALE
DATE
March 2004
PROJECT NO.
2711.1R1
1" = 2000'
Figure 1
Copyright. Upp Geotechnology, Inc.
2 -49
I
I
I
I
I
I
I
I
I
I
I"
I
I
1
I
EXPLANATION
I
Qls - Landslide Debris
QTs - Santa Clara Formation
~ strike and dip
landslide
syncline
". f .
-r--... fold aiels
dotted where concealed
arrow show direction of plunge
I
@adscarp
) \ ' general direction
\ of movement
I
BASE~ Geologic Map of the Sargent-Berrocal Fault Zone Between Los Gatos and Los
Altos Hills, Santa Clara County, California; Sorg and MCLaughlin; 1975
LOCAL GEOLOGIC MAP
__ ~===JN~
I
YATES PROPERTY
22292 Regnart Road
Cupertino, California
APPROVED BY
SCALE
PROJECT NO.
DATE
1" = 1000'
2711.1R1
March 2004
Figure 2
2 - 50
Copyright - Upp Geotechnology, Inc.
\
\~
~l\~' ;
If\;I~ .~
lr {-'~ !. ;
~ r 1t-j-..l--__ ______ .
~/1.,fl , i -;-___..........
I .- f.........~ ~----.-- -....,
., ----- ...... , .,
. I ...._---___.... ....,.... ",
,
8
'ill
13
IH
b
1
1
8
'w
oS
.~
.8
~
I d
dl~
~ ~ ~~J
I
N
IS
'.::I
!!
oS
!l
::::I
I
..
g,
~
B
f
la
:J
~
'iil, 0'
HH~
t-I 'rl Y.
sf
~i
5j
I!!'
sf
if
a
"....
\~
\1<;.
\~
\
i
M I'
i::
~
I
..
S~
J
ci
Zg
~ .
~~
w 0
...lM
~ II
.
.....
2 - 51
.A
- Iv lf5E -=::::;...
510
j:.'
~
~ 5lIO
<.
~
s:
lAt
lii '(SO
~
j::
<'
...
~
ac::
IV,.
~,o
~ _ L....TIO~ t>I' (P) I$l/DnlUE I
BASE: Tape, CCIIplSS, and hand level survey; llPP G&JIE:llNOLClGr, niC.I 2-6-04
I\.)
C11
I\.)
=,
I
I
i
-.;::
8'-
SANTA CLARA FoP.MA.1'lo/J
SAWDSTONE AND SILTSTONE BEDR.oC.K
AI
N'8E-=-
GIOClIOOIC CRCES-SPX:TI~ A-ll.'
~., upp GEOTl!CHNOLOGY
U Engh......lleaIosw.-lftgfNBfng
YATES ~
22292 Regnart Road
Cupertino, California
SCAlE
1" = 20'
PROJECT NO.
2711.1R1
DATE
March 2004 I Figure 4 I
ccp,rigl1l- upp -......,. Inc.
~
s
~
~
....
~
111
~
I{j
~
j::
<
.....
....
Q(
B
~N'3V-
f APPRO"/. IL>cATlluJ "J: P"o"oS~JJ_II.ESI DENlt; ..
.
510
I{,o
m
SANTA C/..AAA FoR.MATIO)J
.s1l1J~'srONE A)lD :!./LT 5ToNIi 16&DR,OC/<
B'
GEXlLCGIC CR~CN B-B'
-tY1i1 UPP GEOTECHNOLOGY
UJ ~ng-' _IaIEnglnftrtng
SCAlE
1" = 20'
Bl\SE: Tape, c:x:rIi'Msr and hand .level survey; UPP GEXJrEJ:HNC][L'r ItI::.; 2-6-04
I\)
CJ1
W
YATES. PRClPEXI'!'
22292 Regnart Road
Cupert1no, Califomia
PROJECT NO.
2711.1R1
DATE
March-
CappIIghI-lJPP GoaIodIoaIagr, Inc:.
I
I
I
I
I
I
I
I
I
I
I
~
~
63
z
~
t:)
...J
~
~~
15 i ~
u. ~ c;;
~ ~ w
%:a:~
~;Cii
i!:...J
~!:2
~
PRIMARY DIVISIONS
GRAVELS
MORE THAN HALF
OF COARSE -
FRACTION IS
LARGER THAN
NO. 4 SIEVE
SANDS
MORE THAN HALF
OF COARSE
FRACTION IS
SMALLER THAN
NO. 4 SIEVE
CLEAN
GRAVELS
(LESS 1 HAN
5% FINES)
GRAVEL
WITH
FINES
CLEAN
SANDS
(LESS THAN
5% FINES)
SANDS
WITH
FINES
SILTS AND CLAYS
LIQUID LIMIT IS
LESS 'THAN 50%
SILTS AND CLAYS
LIQUID LIMIT IS
GREATER THAN 50%
HIGHLY ORGANIC SOILS,
GROUP
SYMBOl
GW
GP
GM
GC
SW
SP
SM
SC
ML
CL
OL
MH
CH
OH
Pt
SECO~RY DIVISIONS
Well graded grallels, gravel-sand mixtures, little or no
fines.
Poorly praded gravels or gravel-sand mixtures little or
no fineS. '
Si~ty gravels. gravel-sand-silt mixtures, non-plBStic fines.
Clayey gravels. gravel-sand-c1ay mixtures, plastic fines.
Well graded sands, gravelly sands, little or no fines.
Poorly graded sands or gravelly sands, little or no fines.
Silty sands, sand-silt mixtures, non-plastic fines.
Clayey ~nds, sand,..clay mixtures, plastic fines.
Inorganic silts and very tine sands, rock..~pur si/t.y or
clayey fine sands or clayey silts with s,""ht plasticity.
Inorganic claY>" of low to medium plasticity, gravelly
clays, san~y clays, slltv clays, lean clays.
Organic 'silts and organic silty clays of low plasticity.
Ino~nic sjhs, micaceous or diatomaceous fine sandy or
Silty solis, elastic slits. .
InorganiC clays of high plasticity. fat clays.
Organic clays of medium to l:Iigh plasticity, organic silts.
UNIFIED SOlL CLASSlFICATION SYSTEM
Peat and other highly organic soils.
200
U.S. STANDARD SERIES SIEVE
40 10
SAND
4
CLEAR SQUARE SIEVE OPENINGS
314M 311 12"
GRAVEL
FINE I CMRSE
SILTS AND CLAYS
I
I
I
I
!
~
~
fa
z
~
t:)
UJ
Z
tr
~
15f5lii
~j~
~:~
a:i
~ i~,
FINE
I
MEDIUM
" COARSE
GRAIN SIZES
COBBLES BOULDERS
SANDS AND GRAVELS BLO\NS/FOOT t SILTS AND CLAYS STRENGTH · Bl.DNSIFOOT t
VERY LOqSE 0-' 4 VERY SOFT 0 - 1/4 o - 2
SOFT 1/4 - 1/2 2 - 4
LOOSE 4 -10 FIRM 112
- 1 4 - 8
MEDIUM DENSE 10 - 30 STIFF 1 - 2 8 ... 16
DENSE ~-50 VERY STIFF 2 - 4 16 - 32
VERY DENSE ()JER 50 HARD OVER 4 OVER 32
tJ
upp GEorECHNOLOG~ 'NC.
Englneerfng Geology . Geotechnical Engl~erlng
RELATIVE DENSITY CONSISTENCY
+ Nmnber of blows of 140-pomd luunmer falling 30 inches to drive a 2-inch OD. (1 3/8-inch LD.) split ~
:J: Unconfined compressive strength in tons/sq. ft. as determined by laboratory testing or approximated in general conformance ~th
the standard penetratiOn test (ASTM 0.1586), pocket penetrometer, torvane. or visual observation
SOIL STRENGTH
KEY TO LOGS
YATES PROPERTY
Cupertino, California
PROJECT NO.
2711.1R1
DATE
March 2004
Figure 6
I
I
I
I
L -"'"1'
I
I,
I
I
,I
I
I
I
I
I
I
I.
I
I
I
I'
I
I
I
the standard petietrati.on resistance (8PT) blow counts are Qbtained, in general accordance 'With
ASTM Test Pesignation.D1586. The drive weight assembly consists ofa 140-pound weight dropped
through ~ 30~inch free fall.' A standard 2-inch outer diameter split-barrel sampler is driven 18 inches, '
or to practical refusal, and the number of blows are recorded for each 6-inch penetration interval (see
, , Figure A below). The blows per foot recorded on the boring iogs represent the accumulated number
of blows required to drive the sampler the final 12 inches.
Samples holding 2 x 4-inch (see Figure ~ below) and 2~ x 6-inch liners (see Figure C below) are
used to obtain "undisturbed" samples. Blow counts are converted to SPT counts by the following
relation: . '
B =, .00051lE
D~ - D~
Where:
B '= Equivalent number of' blows per foot with a SPT
H = Number of blows per foot actually recorded.
E = Energy in inch-pounds per blow.
Do = Outei4e dia~~ter of. the sampler.
Di. . = .Inside dianl~t~r of the sampler.
Occasionally a portable power driven sampler holding 1 x 6-inch liners is used for field ~ampling (see
Figure D below). Resistance is measured in seconds per foot an4 does not correlate with the ASTM
SPT. Undisturbed sampl~ may also be collected us~g a Pitcher Barrel sampler (see Figure E
below). Material recovered over the length of the sampler is shaded. A measure of resistance is not
collected' with this techniq.ue. '
m ~ ~ ~ ~
8PT 21L Liner 2.511 Liner 111 Liner Pitcher Barrel
Figure A Figure.B Figm:e C Figure D Figure E
, . - Und.i?t:u.med Semple X -.Distw:bed Semple.
Whet~ Qbtained, the' $hear strength of the soil samples using either TOrVane (TV) or Pocket
Penetrometer (PP) devices is 'shown on the:boring logs in the far right-hand column.. '
tI
~ OF FIELD ~LIbl"J ~
YATES PROPERTY'
22292 Regnart Road
Cupertino, California
up.~ GEOTEGHM),l,Oq~ I~C.
Engineering Geology. Geotechnical Engineering
DATE
March' 2004
PROJECT NO.
2711.1Rl
Figure 7
2 - 55
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
EQUIPMENT Minuteman'
DEPTH TO GROUNDWATER Not Encountered
RELATIVE ELEVATION
DEPTH TO BEDROCK
DESCRIPTION AND CLASSIFICATION
DESCRIPTION AND REMAKS
CLAYEY SILT; dark yellowish brown; scattered
rock fragments up to 0.5"; plastic; moist to wet
(Fill)
CONSIST.
Firm
to
Stiff
ML
to
MH
------------------
CLAYEY SILT; yellowish brown; 10-15% Stiff ML
subrounded scattered rock fulgments up to 0.5";
moist to wet (Colluvium)
~----------------
SANDSTONE & SILTSTONE; brownish yellow Very (rock)
siltstone grades to dark yellowish brown Dense
sandstone with depth; slightly mottled; trace rock
fragments up to 0.5" in the siltsone and 2" or
more in the sandstone; sandstone is coarse to
medium grained, sub angular, and well sorted
(Bedrock)
Bottom of Boring = 16.5'
tJ
upp GEOTECHNOLOGY;. INC.
l:nglneerlng Geology' GectechnJcaI EnglneeTtng
Copyright- upp Geolechnology, Inc.
SOIL
TYPE
-16-
IX
63
-17 -
.18 -
.19.
-20-
LOG OF BORING 1
YATES PROPERTY
Cupertino, California
PROJECT NO. DATE
2711.1Rl March 2004
16
FIGURE NO.
B
2 - 56
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I Copyright. Upp Geotechn%gy, Inc.
EQUIPMENT Minuteman RELATIVE ELEVATION 499' LOGGED BY C. Reid
DEPTH TO GROUNDWATER Not Encountered DEPTH TO BEDROCK 3.2' DATE DRILLED 1-16-04
DESCRIPTION AND CLASSIFICATION OEPTIi !:l ~i~ ~~~ ~Ig ~i~
c..
DESCRIPTION AND REMAKS CONSIST. SOIL (FEET) ~ 1U5~ ~8 U) ~
TYPE ~~ en
CLAYEY SILT; yellowish brown; scattered Stiff ML -
rock fragments up to 0.25"; plastic; moist to wet; . 1 .
scattered rootlets (Colluvium) .
.~. ~'
- 3 . 17 21 101
-----------~- -- -- - .
SANDSTONE & SILTSTONE; brownish yellow Very (rock)
siltstone grades to dark yellowish brown Dense .~. ~
sandstone with depth; slightly mottled; trace rock
fragments up to OS' in the siltsone and 2" or - 5 - 77 17 114
more in the sandstone; sandstone is coarse to
medium grained, sub angular, and well sorted; - 6 .
weathered to less weathered below 13' -
(Bedrock) . 7 -
-
. 8 -
.
~ 9 .
-
-10 -
-
.11 .
.
.12 - t--r--
-
-13. ~~
. 85
-14.
.
-15. ~ 50 / 2"
- . .
.16 -
- ~ 50/3"
Bottom of Boring = 16.8' . II .
.
.18.
.
.19-
-
-20 -
LOG OF BORING 2
II YATES PROPERTY
UPP GE01ECHNOL~ INC. Cupertino, California
EngIneering Geology. Geotechnical engineering PROJECT NO. DATE FIGURE NO.
2711.1Rl March 2004 9
2 - 57
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I Copyright- Upp Gtoltchnology, Inc.
EQUIPMENT 8-24 Truck Mounted RELATIVE ELEVATION 500' . LOGGED BY C. Reid
DEPTH TO GROUNDWATER 5.4' DEPTH TO BEDROCK 9.0' DATE DRILlED 1-16-04
. DESCRIPTION AND CLASSIFICATION DEPTH ~ ~ig m!g ~i~ ~
DESCRIPTION AND REMAKS CONSIST. SOIL (FEET) ! ~~l ~8 c I~~
TYPE
CLAYEY SILT; dark yellowish brown; scattered Firm ML r
.
rock fragments up to 0.5"; plastic; moist to wet to to - 1 .
(Fill) Stiff MH 9 21 104
. .
. 2 .
.
- 3 - 10 23 105 2.5
-
.......~----------- -- -- - 4 - ...;. 6
SILTY CLAY; dark brown; scattered subrounded Firm CH - -""-
rock fragments up to 0.25"; plastic; scattered to .~. ~
rootlets; wet (Colluvium) Stiff u
-
- 6 -
10 . 22 102
- 7 -
.
- 8 .
.
------------- -- -- . 9 -
SANDSTONE & SILTSTONE; brownish yellow Very (rock) -
siltstone grades to dark yellowish brown Dense :~:: ~
sandstone with depth; slightly mottled; trace rock
fragments up to 0.5" in the siltsone and 2" or
more in the sandstone; sandstone is coarse to 69 29 100
medium grained, sub angular, and well sorted
(Bedrock) -12 -
-
-13.
.
.14.
.
.15. --
.
.16. X
75 15
Bottom of Boring = 16.5' -17 -
.
.18.
.
-19.
-
-20-
LOG OF BORING 3
II YATES PROPERTY
UPP GEOTECHNOJ.OGY;. INC. Cupertino, California
EngIneering GeoIDgy. GeDleChn/cal Englneertng PROJECT NO. DATE FIGURE NO.
2711.1R1 March 2004 10
2 - 58
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I Copyright. Upp Geolechnology, Inc.
EQUIPMENT 8-24 Truck Mounted RElATIVE ELEVATION 500' LOGGED BY C. Reid
DEPTH TO GROUNDWATER Not Encountered DEPTH TO BEDROCK 2.7' DATE DRlUED 1-16-04
DESCRIPTION AND CLASSIFICATION DEPTH ~ ~~it m~~ >-~a::- ml[
(FEET) ~ I~i lS!2o
SOIL !!eS wE!::.
DESCRIPTION AND REMAKS CONSIST. Ci50 c
TYPE ....ll:!~ U>
SILTY CLAY; dark brown; scattered subrounded Very CH -
rock fragments up to 0.25"; plastic; scattered Stiff . 1 -
rootlets;. moist (Colluvium) 16 21 103 1.3
-
- 2 - X
------------- - 28
-- -- 22 106
SANDSTONE & SILTSTONE; brownish yellow Dense (rock) - 3 -
siltstone grades to dark yellowish brown -
sandstone with depth; slightly mottled; trace rock - 4 - ~"- 33
fragments up to 0.5" in the siltsone and 2" or .
more in the sandstone; sandstone is coarse to -- -5-~
medium grained, sub angular, and well sorted Very - ~ . X
(Bedrock) Dense
86 14 120 7.8
- 7 -
-
- 8 -
-
- 9 -
.
.10- -r--
-
-11- ~'- 90
.
.12.
-
.13.
.
-14.
-
-15. xr 50/6"
19
Bottom of Boring = 15.5' -16 -
-
-17 -
-
-18.
-
-19 -
.
- 20- .
LOG OF BORING 4
tJ YATES PROPERTY
UPP GE01ECHNO~ INC. Cupertino, California
Engineering Geology. Geotechnical EngIneering PROJECT NO. DATE FIGURE NO.
2711.1R1 March 2004 11 ,
2 - 59
I
I
I
I
I
I
I
I
I
I
PLASTICITY CHART
I
I
60
50
-
';F. 40
-
~
c
25
~ 30
(3
i=
j 20
Q.
10
0
0
I
I
I
I
I
..............
.GI.; : Ml.; . . _ _ . _ _
ML
I
10
20
I
40 50 60
LIQUID LIMIT ('Yo)
3D
70
80
90
100
~.. ;-,L"";tl ~ i-"""~'... ,,:..~.,.. ~~ ( !J...; ~.,~H~~t....~::yL,~~...~ 'T' ..~....), . ,,:...-;'t ~~',.,.lJ~~,1.:.( r 15~"~J .:..l;f'..::'"l ~J-:'" f,..,r,'~ "'t'~"- II' fu;,'\~t~!-i:.'f~t. ~~'11 h' l' :fi('.~i';.~1 ~.l.,,J"..'!l.... )~... -~);o,\:.-r ."", , '--. I ,?1~~, '_ I L ~ 1 ~,~~ '-;..i..f, ,I ~ _ 1 ,.
,. I" I.. 'CO If .,,""'~' ~,,;,~,,,""" "-." d. ~r. ,,- "..."""iJ\tLld-C~' "' ,,1\< ,PI.. +.",,,,,,~,. ","'.s ,1'':oI'Z'''"",>I,'"'.,' .,,, 'w ',- . -I; """"'~';,,'i-t r?!'''"1 "," .' 'c', , <,. 1,'1"., ~'," 'I~'" .
~I' I'....').............. IJ ,,- '~.Jt~" ~.~I .~, 1'! ,.I~~,'GJ~ .~f:...} '/);1" ,-. )rl\:;r;;;""1[:~U:.~:::.'< '--~" ~"rf'~l "J~:t ~'~~;>>:.J;'~'".;f,'~~lat~ ~ I"''''''' ,., ~'", .-\ ~'~"L ,'" - ~
f::l~l.\ :{~.1-:~:!x~ ~;'~ll~~i~~~{;~):l::li!1;~~ ~7~~ j'r~ '~.:~,!~~>:l:~,!'1~~;1 r ~~l~ 1~:~~~~~1~~~~~.t~~ffil~r~~co1~;4~ l~~-ftt~l~~'tiff\)bi",',~~".:;-A '>J~~ ~:~~!l~~ >~:'rU'l. -~"~'" -~~f~J1~,i~r\ ~~..~11 \r--~
,r -l,' ",'''''. ...~~- -' i:t';'V,r J. &0 -,~f ., ".'> ..,...~ "_,'J,;; ~~~..;~~:. ,~-....,..,.. ~~1...... - { '7 '\~i"1 ~~".\ .I' '.'l! ~" _1..";"" \ 1 ~ \ ~.., ,'" " I
,'. If;~''CY " ;-t;;L;{rl;J~t~,. j , ,$~\'~IA,Zh,.. . . ./!i'/f;,,\ %,~~~,~,' ""l., " I"~,,ii.;, f\~ ';llrt'nr.~~V~I' ~.,~ ""'Ul"J\t'!:(l' :~'I\b:.,\~;.."l~t"T J:.181~ 11lWUa'/. ~61';J"{~.11-IlN:I_"'I; 1 ,1
'.....'.''l,. 1" 1~f~' (":~",',,\)~-:~ .;l....~.ija,--......~cf~.... ~-.\-n';,-~- .~ ,j..(;g~.~}.,~r. 'H~;:....{..;;I~I.;~......' _..,.~n~';lr:~~,t:lh~'-:.~ :i:f'~~j'<'r}""""""l~\j~l~~"'~ ~l.:~~"";.1;"; I],.:,("..,,~.nt~
,', ;'fiJ'~~~,*c.ri;; ?J~:J~;;1-.i'\!;~J/~@t;'tft1 f.~;~gl(~,(2~~1~1;;;;;'~1ij~~~f;~1;J)!1'~i1'~~\~1~;t'!5'I~i;-;:.{<ir~~,.,l;.<S/,1 riiJl~,~"f'f2;I$:\~':l;i:l"{~,:, 'JI~,~,<;:.".: , .c:~""ih-~~ ~ f::~!.~+- I'"
~\:: ,-:' .. ~t-1.E:;""h: ';"1% :;1 !~~:.;~z;~:r~ i':~?1~l:-r:Z;~ .~-;i, w ?-!~ :~-~iJ;~'i~r..;>>~~hf.7r~":;'. ~\r;,;p/!~~q;'i'~:;~tfi ~!t~~~~~~.~.t~.-::i:~tl~r '>:"<im~l,t;\~~ ~'~~{L0>1~~"'~:.1;; ~ ( _~:J:"l ,.~~\.\: !: ~ >1~~ r~ ~, ':\y.l;f ~ I~ \r"~
-tl~/I,:;i'J~~..4 ~':l ::[\.tA""':~J)~~-d~';j,~~.;~:ft}f{':'.:J.trn.Hi~~~)~l~':': r,;;~ ~!\l'~~~~~r..;,~~~~,;;tf.i,!'"f.F;~~~ l,..~,'f r.rf4~7r'i.r~ ~fJ;t. !),~~~~,.. .1'!, ~!i:!.l~t""r:j:rr ':at, '.' ~ '{il1"\,tT "l~J?'~~;:O; '1;":'\ ~~{.. ~,q.YM~ ~..8
o
84-1
1.5
21
50
31
19
67
0.07
CH
PLASTICITY CHART
.:~=.~=~~-~
YATES PROPERTY
Cupertino, California
PROJECT NO. DA TE
2711.1Rl
March 2004
Figure 12
Copyright - Upp Geotechllology IlIc.
2 - 60
I
I
I
I
I
I
'I
I
I
I
I
I
I
I
I
I
I
I
I
APPLICATION FOR AUTHORIZATION TO USE COPYRIGHTED DOCUMENT
NOTE: TillS APPLICATION MUST BE COMPLETED FOR USE OR COPYING OF THE
FOLLOWING DOCUMENT BY ANYONE OTHER THAN THE CLlENT.
GEOTECHNICAL INVESTIGATION
NEW SINGLE-FAMILY RESIDENCE
YATES PROPERTY
22292 REGNART ROA.D
CUPERTINO, CAUFORNIA
MARCH J J, 2004
PROJECT NO. 2711.JRJ
TO: Upp Geotecbnology, Inc.
750 Camden Avenue - Suite A
Campbell, CA 95008
FROM: Please clearly identify
name and address of
person/entity applying
to use or copy this
document
APPLICANT: hereby applies for permission to use
the above referenced document for the following purpose(s):
Applicant understands and agrees that the document listed above is a copyrighted document, that
Upp Geotecbnology, Inc. is the copyright owner and that unauthorized use of copying of the
document is strictly prohibited without the express written permission of Upp Geotechnology, Inc.
Applicant understands that Upp Geotecbnology, Inc. may withhold such permission at its sole
discretion, or grant such permission upon such terms and conditions as it deems acceptable, such as
the execution of a Hold Harmless Agreement or the payment of a re-use fee.
Dated:
Signature
Title
upp GI!OTECHNOLOGY,. INC.
2 - 61
.
ARBOR RESOURCES
Professional Arboricultural Consulting & Tree Care
Exhibit C
A TREE INVENTORY AND REVIEW
OF THE PROPOSED DEVELOPMENT
AT 22292 REGNART ROAD
CUPERTINO,CALIFO~
Submitted to:
Colin Jung
Community Development Department
City of Cupertino
10jOO Torre Avenue
Cupertmo, CA 95014-3255
Prepared by:
David L. Babby, RCA
ASCA Registered Consulting Arborist #399
ISA Certified Arborist #WE-4001A
June 22, 2007
P.O. Box 25295, San Mateo, California 94402 . Email: arborresources@comcast.net
Phone: 650.654.3351 . Fax.; 650.240.0777 . Licensed Contractor #796763
2 - 62
David L. Babby, Registered Consulting Arborist
June 22, 2007
SECTION
1.0
2.0
3.0
4.0
5.0
6.0
6.1
6.2
EXIllBIT
A
B
TABLE OF CONTENTS
TITLE
PAGE.
INTRODUCTION ..... ........................ ............. ........... ...... 1
TREE COUNT AND COMPOSITION ..................................1
SffiTABILITY FOR TREE PRESERVATION ....................... 3
PROJECT REVIEW.... ......... ... ... ... ....... ... ..... ... ............ ..-. 4
TREE REPLACEMENTS.. ............... I,................... ... ......... 5
RECO~NDATIONS ....... ...... ................. ....... ............ .... 5'
Design Guidelines .................................,............;........ 5
Protection Measures Before and During Development. . .... . .. .. 7
EXHmITS
TITLE
TREE INVENTORY TABLE
SITE MAPS
2 - 63
David L. Babby, Registered Consulting Arborist
June 22, 2007
1.0 INTRODUCTION
I have been retained by the City of Cupertino Community Development Department to
review the following items associated with a proposal for the futur~ deve~opment of 22292
Regnart Road, Cupertino: [I] demolish an existing residence, [2] construct a new residence
and detached garage, and [3] install an expanded septic leachfield downhill from the home.
Tasks performed for this review a,re as follows:
· Identify trees situated within the immediate proximity of the area proposed for
development.
· Distinguish between "protected trees" versus not-protected trees (pursuant to
Section 14.18.035 of Cupertino's Municipal Code).
· Estimate their trunk diameters at approximately 54 inches above grade or as
appropriate to obtain the most representative sample of trunk size.
· Estimate canopy spread and ascertain the trees' health and structural integrity.
· Determine the trees' suitability for preservation (e.g. high, moderate or low).
· Review the two survey plans by Ward Surveying, dated 3/14/07.
· Assign numbers to each tree and plot these numbers on the two maps presented in
Exhibit B (the maps are copies of the survey plan showing the proposed features).
· Recommend replacement trees, and comment on planting trees in leachfields.
· Prepare a written report containing t~e aforementioned information, and provide
measures to help avoid or mitigate anticipated impacts to trees that will be retained.
2.0 TREE COUNT AND COMPOSITION
Sixty-two trees of fifteen various species were inventoried for. this report. They are
sequentially numbered as I thru 25,1 and the table presented on the next page identifies
their name, number and percentage. Specific information recorded for each tree can be
viewed in Exhibit A (Tree Inventory Table).
1 Note that trees #24 and 25 are comprised of separate groves of trees, 16 trees for #24 and 11 trees for #25.
22292 Regnart Road, Cupertino .
.City o/Cupertino Community Development Department
Page 1 0/9
2 - 64
David L. Babby, Registered Consulting Arborist
June 22, 2007
Almond 28,29 2 3%
Avoaado 26 1 2%
California Black Walnut 24 1 2%
Chinese Elm 12,33 2 3%
Coast Live Oak 1-4, 6, 15-21, 23, 30, 15 24%
31
Douglas-Fir 9-11 3 5%
Hollywood Juniper 8,25,27 3 5%
Incense Cedars 25 2 3%
Italian Cypress 34-37 4 6%
Linden 7 1 2%
Madrone 13 1 2%
Monterey Pines 22,24,25 24 39%
Persimmon . 32 1 2%
Shamel Ash 14 1 2%
Wattle . 5 1 2%
Total 62 100%
Nine of the inventoried trees are defined as "protected trees" (Section 14.18.035 of City
Code); they include #1-4,15,16,18, 23 a~d 31, all of which are coast live oaks.
22292 Regnart Road, Cupertino
City o/Cupertino Community Development Department
Page 2 0/9
2 - 65
David L. Babby, Registered Consulting Arborist
June 22, 2007
Forty-four of the total 62 trees are nof shown on the plans; they include #4, 6, 8-11, 13,
14, 17-21, 23-26, 30 and 33-37; note that tree #24 is comprised of 12 trees not shown, and
#25 of 11 trees not shown. The roughly approximate locations of these trees are presented
on the map in Exhibit B; however, no~e that they were visually estimated and shall not be
construed as accurate or being surveyed.
Two of the inventoried trees, #26 and 32, are fruit-bearing trees. Three additional trees
are nut-bearing and include #24, 28 and 29; each is very small in size and are less than 10
inches in trunk diameter.
3.0 SUITABILITY FOR TREE PRESERVATION
Each tree has been assigned either a "high," "moderate" or "low" suitability for
preservation rating' as a means to cumulatively measure their physiological health,
structural integrity, anticipated life span, location, size and specie type. These ratings and
applicable tree numbers are presented below; note that the "high" category is comprised of
11 trees (or 18-percent), the "moderate" category 21 trees (or 34-percent), and the "low"
category 30 trees (or 48-percent).
Hie:h: Applies to trees #2-4,15-19,21,23 and 31. These trees appear in overall good
health, seem structurally stable, and have a seemingly high potential of providing a
long-term contribution to the site.
Moderate: Applies to trees #1, 6-14, 20, 22, 27, 28, 30, 32-37. These trees require
frequent care throughout their remaining life span and provide less significance than
those assigned a high suitability.
Low: Applies to trees #5, 24 (16 trees), 25 (11 trees), 26 and 29. These trees are
predisposed to irreparable health and/or structural problems that are expected to worsen
regardless of measures employed.
22292 Regnart Road, Cupertino
City o/Cupertino Community Development Department
Page 3 0/9
'2 - 66
David L. Bobby, Registered Consulting Arborist
June 22, 2007
4.0. PROJECT REVIEW
Forty-four trees are in direct conflict with the proposed design and will require
removal; they include #7-11, 13, 14,20,21,23-29,32,34 and 35. One of these, #23,
is regarded as a "protected tree" as it is a native oak. with a trunk diameter of
approximately 14 inches; it appears stable and in vigorous condition. If its long-term
survival is expected, the leachfield lines should be established at least 15 feet from its
trunk.
There' are two additional "protected trees" that would be adversely impacted through
implementation of the proposed plans. One includes #18, a 10-inch diameter oak. in
overall good condition, and the other is #31, a 20-inch diameter oak also in good
condition.
As for tree #31, the impacts include trenching within its root zone, an activity that can
be. easily mitigated through hand-digging where within 15 feet from its trunk. Tree
. ,
#18, however, will require the leachfield lines be'setback by at least 15 feet from its
trunk.
Tree #5, a fairly large wattle, has a large crack through the middle of the trunk at about
20 feet high where two leaders originate. Consequently, the tree should be removed,
regardless of the proposed project, as the top portion is at severe risk of splitting and
falling from the tree.
All other, trees are expected to survive and be adequately protected provided the
recommendations presented in the next section are carefully followed and incorporated
into the project plans.
22292 Regnart Road, Cupertino
City of Cupertino Community Development Department
P{1ge 4 of9
2 - 67
David L. Babby, Registered Consulting Arborist
June 22,2007.
5.0 TREE REPLACEMENTS
I recommend Table A, Sect~on 14.18.185 of the City Code, is used as a basis for
determining the size and amounts of replacement trees. Trees planted beyond the
leachfield (such as 20 feet beyond) should be comprised of any of the following: coast live
oak (Quercus agrifolia), valley oak (Quercus lobata), big-leaf maple (Acer macrophyllym),
.. and/or California buckeye (Aesculus californica).
~s for trees planted within the leachfield area, significant consideration should be given for
small, less-aggressive species due to the risk of woody roots from larger trees clogging and
damaging the lines. Several options of trees that may be appropriate include strawberry
tree (Arbutus unedo), elegant tristania (Tristania laurina) and Carolina laurel cherry
(Prunus c. 'Bright 'n Tight'); I caution that any tree selected should be slow-growing and
not require high-water use.
To achieve the greatest assurance of proper installation, all new trees shall be installed,
including necessary irrigation, by an experienced and knowledgeable state-licensed
landscape contractor (or a professional tree company). The work shall be performed to
professional industry standards.
6.0 RECOMMENDATIONS
Recommendations presented within this section serve as guidelines for achieving adequate
protection of trees that will be retained. Please note that any or all recommendations are
subject to revision upon reviewing any revised plans.
6.1 Design Guidelines
1. The plans should show the location and assigned number of each inventoried tree.
2. The location of trees #4, 18 and 23 should be surveyed to identify their specific
locations on the site (these are three of the "protected trees" not currently shown on the
22292 Regnart Road, Cupertino
City o/Cupertino Community Development Department
Page 50/9
2 - 68
. David L. Babby, Registered Consulting Arborist
June 22, 2007
plans). I also recommend the canopy dimensions of all nine "protected trees" (#1-4,
15, 16, 18,23 and 31) are shown on t~e plans.
3. In the event trees #18 and/or 23 are to be retained, I recommen4 a minimum IS-foot
setback from their trunks for any leachfield line.
4: This report should be incorporated into the final set of project plans, titled Sheets T-1,
T-2, etc. (Tree Protection Instructions), and referenced on the Site Plan and landscape
plans.
5. The permanent and temporary drainage design, including downspouts, should not
require water being discharged beneath the trees' canopies.
6. Except as otherwise addressed in this report, all new utilities and services must be
routed beyond the canopies of retained trees (see Section 6.2 for fencing locations). In
the event this is not possible, I should be consulted for alternative installation methods.
7. The proposed landscape design should conform to the following guidelines:
a. Turf and plant material should be avoided beneath the oak canopies; as an
alternative, I suggest a four-inch layer of coarse wood chips (decorative or from a
tree company).
b. Irrigation beneath the oak and cedar canopies can impose adverse impacts and
should be avoided. If applied, it should be low-volume, applied irregularly (such as
only once or twice per week), temporary (such as no more than three years), and
not strike within five feet of its trunks. Irrigation should not strike the trunks of any
other trees (new or existing).
c. In the event trenches for irrigation and/or lighting are required beneath a canopy,
, they shall be installed in a radial direction to the trees' trunks. If irrigation trenches
cannot be routed as such, the work may need to be performed using a pneumatic air
device, such as an Air-Spade@, to avoid unnecessary root damage.
22292 Regnart Road, Cupertino
City afCupertino Community Development Department
Page 60f9
2 - 69
David L. Babby, Registered Consulting Arborist
June 22, 2007
d. Stones, mulch and fencing should not be placed against the trunks of existing or
new trees. Plastic ground cover should also be avoided beneath canopies.
e. Tilling beneath canopies should be avoided, including for weed control.
f. Bender board or other edging material proposed beneath the canopies should be
established on top of existing soil grade (such as by using vertical stakes).
5.2 Protection Measures before and during Development
8. Tree protective fencing shall be installed prior to any demolition, grading,. trenching or
site clearing work. It shall be established to restrict access beneath the canopies of
retained trees, and established at least 12 feet southeast from the trunks of trees #1 thru
4. It must be comprised of six-foot high chain link mounted on eight-foot tall, two-
inch diameter steel posts that are driven 24 inches into the ground and spaced no more
than 10 feet apart. Once established, all fencing must remain undisturbed and be
maintained throughout construction until final inspection.
9. Unless otherwise approved, all development activities must be conducted outside the
fenced areas (even after fencing is' removed) and off unpaved areas beneath the
canopies of trees inventoried and not inventoried for this report. These activities
include, but are not limited to, the following: demolition, grading, stripping of topsoil,
trenching, equipment cleaning, stockpiling/dumping of materials, and
equipment/vehicle operation and parking.
10.1\11 existing, unused lines or pipes beneath the canopies of retained trees should be
abandoned and cut off at existing soil grade (versus being dug up and causing
. subsequent root damage).
11. Any approved digging or trenching beneath the trees' canopies shall be hand manually
performed (Le. hand dug) using shovels. Roots exposed with diameters of two inches
and greater should remain intact, and if necessary, tunneled beneath. If an exposed
root must be severed, the work should be performed within 24 hours and the root cut
along the tree side ofthe excavated area..
22292 Regnart Road, Cupertino
City o/Cupertino Community Development Department
Page 70/9
2 -70
David L. Babby, Registered Consulting Arborist
June 22, 2007
12. Excavation for the section of basement within 20 feet of tree #4 should not require
more than a 24-inch overcut; to achieve this, soil nailing and shotcrete construction
may be necessary.
13. Any trench dug beneath or near canopies of retained trees should not require more than
a 24-inch overcut towards a tree's trunk.
14. Prior to demolition, I recommend a four-inch layer of coarse wood chips (~- to %- inch
in size) is manually spread on unpaved soil beneath the canopies of trees #2 thru 4.
These chips must not be placed against the trees' trunk, should remain throughout
. construction, and can be obtained from a tree service company and/or by contacting
www.reuserinc.com.
15. Any approved activity required beneath a tree's canopy (within and. beyond the
designated . fenced areas) should be performed under the direction of an individual.
certified.by the International Society of Arboriculture (ISA).
16. Each recommendation that is presented within Section 6.1 of this report and applicable
to implementing the project plans shall be followed.
17. Soil extracted from any trench shall not be spread or displaced for more than 48 hours
beneath a tree's canopy.
18. Throughout development during the months of May thru October, supplemental water
should be provided to retained trees. In doing so, a substantial amount of water, such
as 10 gallons per every inch of trunk diameter, should be applied every three to four
weeks on the ground beneath. the canopies using soakers hoses or by hand-watering.
The focus is to uniformly wet the area to a 24- to 36-inch depth, and permitting the soil
to dry between applications.
22292 Regnart Road, Cupertino
City of Cupertino Community Development Department
Page 80f9
2 -71
David L. Babby, Registered Consulting Arborist
June 22, 2007
19. The pruning and removal of trees shall be perfonned under the supervision of an
individual certified by the ISA (and not perfonned by construction personnel). Any
tree stu.mps being removed beneath or near canopies of retained trees should be ground
below grade rather than pulled up with an excavator.
20. Great care must be taken by equipment operators to avoid the trunks and branches of
trees during operation.
21. The disposal of harmful products (such as chemicals, oil and gasoline) is prohibited
beneath canopies or anywhere on site that allows drainage beneath canopies.
Herbicides should not be used beneath the trees' canopies; where used on site, they
should be labeled for safe use near trees.
Prepared By:
./.... . ~. .
~.
Date: June 22. 2007
David L. Babby, RC
22292 Regnart Road, Cupertino
City of Cupertino Community Development Department
Page 9 of9
2 -72
David L. Babby, Registered Consulting Arborist
June 22, 2007
EXHIBIT A:
TREE INVENTORY TABLE
22292 Regnart Road, Cupertino
City of Cupertino Community Development Department
2 -73
:mg'::,~. '. .., .
'Nb::, ':- ""., <fREENAME- ,: ;:~
'-~ ... .., ... , " 0:'
.. .. l...' .
TREE INVENTORY TABLE
": " " ." ::{ >i>f <gt":"iI:n f~":';:<.~?
. ~,-..' : :3~" >.g.s..: i:.s' :~.lr .::,::'j,.:~'if~:~~: :::~8:' 't:::
'. .~ '~ , '. . ; .:ai' '.' . ~.~' ..... ". "0 .~... ,:,' OS....ij. <'. ":':".~ ....0,--' ,.. C:'.,' -, ...q ",.'
.. ~ ~ .: "d'::I <.8:.:' :l-.jr: >'r~ -.!:i::---: >.:g~c' ~:i':.:. tJ.:..c -". ~ .. ~ :~ >>:
~ v . v.~ ".. ~: I.' ' . .,,...,,.... ~ .~. '_ ':1::;~.'., '0 ib'~"o" ",. fO..,,~ "
:.:!'tiI:l.: :::~~"":';:S:~: ,:1r~-c,,: :':l~: :llir Jfl<:"i.- <:.:c:::.:.
" '''13;' ".. 'V'O .. c -. ./:l"0. ''?' -.... .'g-:.::l" .... ,II., . .c. .0.. ...1"<.... "0""
-' .fI).^. "~d: "ifl).O" ",0.',-,,'. ''''fI).e.'.Ec '.E,~, ...~; c.., '.;
Comments:
Coast Live Oak
(Quercus agrifolia ) 75% 50%
Comments: Contains trunk damage likely due to deer.
Linden
(TWa cordata)
Comments:
Hollywood Juniper
(Juni erus c. 'Torulosa')
Comments:
Douglas-Fir
(Pseudotsuga menziesii)
Comments:
Site: 22292 Regnart Road, Cupertino
Prepared for: City of Cupertino
Prepared by: David L. Babby, Consulting Arborlst
10f4
June 22, 2007
2 -74
.TREE INVENTORY TABLE
.,; }.> tJ~:~:<:1: ~{:b: :;J:; :;:::j l::: : ::.. :> . .::
.. , ."" ,..~,., ,', e .,Ik ,".~Ik" 'd'~" ,ri,,~, . < tL3 . 1:)' <.' ..", .,a..
<l;~:.': ..:- :~.:::. "'"~J{~;':," :~~~':: ~:~~=8~ :~,::~:;~>::: .:} ~';~~:'.~; ,.: :7e{:':':(:~ .::
. f::(" a'. 'U""" .,:S ..!. ., ',E"tf... - ~ .~. " , . .;:1.., 0 .. . "<0:0:.1'..0. ~L , 'f'< .". ..0. .
.. . .... ";.0, "'<'"d'Z" <.'g:, :>>..Q>: ;:8"lf:,;:>.:g::Arf .:Y:~ ':-:0>: :.>~>:
" . " .' ~'..B' :,,"o.~.. ','P"I'.' ."......'.'.ta..&f....'. "'.:'. ".'~':'.'. "'. .,:.t:.~.., '.".," ".~' '..'it... ......'tr-g. ",.o,,_,.g.,. '..'
, , . : ~~ ~,', ,,:~ ]:-: :-:-s~<.::~:;t< <]:-a: :::~:'i;:.:::~tE. ';=>[:. :~> >~>
" .'.'.1RE..'.E."N".....m. " .a' . ..t:l.~. '''''].0. .....6.O.....?'~."..'s.;,;:I...:s..Il....~:t.e..".€.. "".'0,',
:,.,..... ./'UVlC ...... " A.' ..~'CI)....:I:.c:. ""CI),,'C' ..o.~..~.,.CI)~.:..,..=rc\s,~ .~, .,"z.....
Douglas-Fir
(Pseudotsuga menziesii)
Comments:
Madrone
(Arbutus menzlesii )
Comments: Asymmetrical canopy,
Shamel Ash
(Fraxinus uhdei)
Comments:
Coast Live Oak
(Quercus agrifolia )
Comments:
Coast Live Oak
(Quercus agrifolia )
Comments:
Coast Live Oak
(Quercus agrifolia ) 50%
Comments: Asymmetrical canopy, at downhill side of staircase.
Site: 22292 Regnart Road, Cupertino
Prepared for: City of Cupertino
Prep;fred by: David L. Babby, Consulting Arbor/st
20f4
June 22, 2007
2 -75
.',
TRER
,NO.>
TREE INVENTORY TABLE
,"
. ,,: ;:~.:.:~" ',', <i.:~ ,>' ::;:l::::> :.;:~{. .:~>.".~ :-.,;.:-:.
, ". e ' .. . O' ...' 'g" ... c: ,.,..,' ... ~' ..;.d'" .. '" , " ..
>>:' :.<-:~, . .-:...~... ~<..,.R~ >- u;.~::> :~'-~: :'~>:- '-:.'< .-::~.:::
'j' ..,"',"~.<o,,'_" 't:l'~li' ,,~"Jb,', .".g ~. e.:9. '-~Q ,U"c' "_'.'. v;.!,,
'. . ". ,... "0" , ,., 0.'0'" 'Qj)"~. ":j:l' 0 " ~u'ii. - Po.".l .-, bO' , '-u' . c:L/- ,-
,'. ..."""".....sr.'. . ,"','c.o"""'B"c.;;>'."'v,:,a'o. ,'..'....:e..'. ..8.Jli.' -,r:s"f'i' . .u'. ....c-',;.
"'8"'S~' .. ()."...., .;-.:a"fl', :', :f;l,.tf-, ""'c:l,~". " '.g"u',", ,.t:;"'...r"'-cft:5" , ,,~-,""",'..C1-,
':-'3:'lf:"" "'-.'. :'g:.g.......:::8:.~.,..,::~:~':;:::.8:~:.. .<.~-oi-o.....:.: ::~...J....... ;',ft. :."8' :::-0.11)::: ::::~'.-::
.. ~"'d) -.. ,:a; '..g- " ":s'l' "'B'~ ,', ~.'O.:' ,':s"" ,~-'bO; ,.O,'fIl. < .'B'.: ",-].
:-'~:J: :-'.Jf. [:: :: ] gO:: :': j :8:-. :~. :..8':: : <. - ,~:~":. J _~'.:'~.' ~ . :~:;. :.~: .
-.~."". '.Jhn.-' ;:ff.o.:.' '. CI)":::;" "0.8,'. . "CI)..:z,;,', .;S'c' '.s;~. ;.'.~ ':.'Z','
Monterey Pine
Pinus radiata)
Comments:
Avocado
(Persea americana 75%' 25%
Comments: Trunk is about one-foot from existing home,
Hollywood Juniper
(Juni erus c, 'Torulosa')
Comments:
Comments:
Site: 22292 Regnart Road, Cupertino
Prepared for: City of Cupertino
Prepared by: David L Babby, Consulting Arborlst
30f4
June 22, 2007
2 -76
TREE INVENTORY TABLE
. .. ". . .. _. .- -, - .. "' . .
., " .. - .. . > ' r:l
,.. ::~":..:;.:<:'::::: ..:.::~.<:":'?~l"'....<:::>'~:;:.,' ::::~:::~::::: :>>"':' . <"::,'
". .. .. " , . , . ". ".' " .~., .b"~" ." 'I -. " ", ~.~ .' - 'ts '3: . ..,~- , " c..,,, . 'i""
.':: i ~:':'~:~'~:l :',::: .:::$ :~:'.: : :~::'J.~': :.' ;::,::.~:: : ;.::~:~: ~': .~.~$: ,~~:~~,'~: :<~t~~ ~>t~~~
, ~' a'. 'u"'" ..:0 .+t. , ,.' .s"tr '. . r:l'~ .' ,,,.8.. u ,. .,,' "~'..J< . ...0. "" "r-; ,.,., ,,0, ,
....]:~':: '::.ig':' .:::8:~':"':>.~:'f> :,;~:~=. ;:.:.:g:8i, ::~,:~J.'::~::1S: ':)io:~:: :.:::r;:
. "N' U...... ". 'N' I" .. .,.;3 ~. "'..a"~ ""t'd'-a ' . ".~" '," ,.~.....b.O. .as..""... ".".oJ:l.,
:"'J' :.I:l.,,, >.,,~:- " ':'~~, ,U'~", ,,"~'~": '.:'::3< '." .:la:!E< ,.=.:& <"':<~:',
, "ca...... """" i3'0 .. '" ]'-0.' '."?' ,. r. 'S.;;;:!, , ....,2 .11." . 1=l.'O. . .e. '0"
',' ,A..'.. "t/.). ',,"::1::'.0.' ',; ,'t/.),,:;:j;. '.d,~', ':'t/.),e;.', ,.Erc' '.s.. ..... ,", ~./' ',.,',Z'"
Comments:
Chinese Elm
(Ulmus parvifolia )
Comments:
Comments:
Italian Cypress
ressus sempervirens )
Comrp.ents:
Comments:
Italian Cypress
ressus sempervirens )
Comments:
Site: 22292 Regnart Road, Cupertino
Prepared for: City of Cupertino
Prepared by: David L. Babby, Consulting Arbor/st
40f4
June 22, 2007
2 -77
David L. Babby, Registered Consulting Arborist
June 22, 2007
EXHIBIT B:
SITE MAPS
22292 Regnart Road, Cupertino
City o/Cupertino Community Development Department
2 -78
o
z
~
W
D..
::)
(.)
C
<C
o
0::
~
<C
z
C)
w
0::'
N
en
N
N
N
L
/..->0( \7::::1 ~I
-- .:::J-L S
-
an
N
::::J
...
.c:
~
U)
=1:1:
U)
Cl)
~
~
-
- .cia _ ;1903 ~"g /
-"r-:::::--=--=---"-"-~' _Ha~2. \!!/ ~'2Y@;l~ ~O~ ~ -/-
~ /r -- -- --. - - - - ..;;-----. ; %Q) ..' ('~
-- .. ~~ - '--" - .. "
~ - ~ ----...: + '-'
,,/ ---------"- --......~ --,' ~~~ / (/) ~
/" ,,_ _ . .,. ,'" ~~H .9 · ·
/ ________ _ __ ". '0--,. " ",-'~ '0 z
/: ___ __'_. .... '", ' ,,__" / z -
--- _: - - - - -"..
../" /__------' ~._._ u.:::' .~~~,' a
/' ,// __ ___ _.j} "_ .~.. ' . ' ___ UJ
/ __ _=~,_ __ ,,"----._?t---- " ....... ,_ 0-
7''' . ,,:0.- 'c"..0 _ _ *___ .~ .....:----- - - - D.
/~....J ~f.:-""""'- ~"_ __. __ ~==-~-.... -.f}.......... ---. ----___--~. ~ Z .A"
. .. - "-' ~ .' - . ~
. ~ --::.._ __, C', __-:.." ;-:--' .,..,------' -' .L
, / .:f ' 101,""'';- -. .~ '.';:;' ~. ':--, - ------- --
I A~ t mil -- ~!l;~f(:- . ~~~<>:~--:::::.<::-.....~'< &
'"'V-1J r><o - , . "'"- ..... ' ....... ~. '-.......
If !< !l!),iD .--.~"--II '----..~- -,-~ ~'-..., --<:' "...."""- ::L .
'"' 'U \J .,_..--:" I \/ .. .. ~' '---- (), , ..... '- ---;ft j
~ It' /....... "'" .' "" '.. ~~ -- -r.o'" .... ---~
. . . _./ .... I .. Y" . --x' },-, ."" ~' " ", .... "- ~ :
'^!f ~_' _ ~ ~~----~,...:,';:," :"'" -~" '-....._,-1--
. . ,~~-:.._ 1//' o-........~~::.. ..~~~. ---......, ~.~:,
" _ , _ />Y'.I ." _ . ... ", .~..... ~ Os' ':. .-
/\. . V ,/ ./ ~-~!~ 1 ~ ,'- ... -' .
,. _ . ? /,4/\,...:: / ,~__ ~~'7- ........... -~ ......... r.Jl< - '<. ........ \' "
, j/Jf 1/; /<::::..-=--=---'- :- .-- -- -~ ., ......... .......~........" '" \ \ -,
../ ~..~/ Y /:/ </ ~ -= _-_ ;.-:::"< ~-;:-~ .............. :'----,'"-t. \\ ~. '
" ,. ~/_. _ " _ v,. ~.. "'<t. ~,f
<" / /' ".4V '.u 0';' " -- A:O _____..... ., ~ .......... ; IL '---- ..... 0. '\ \ ---
/ %h ~~ _ 7- ""'._.-r.~~~~~"'09 ,)~\:\ . /
. ;''/,1/. j / /]!: -:- - -f' 7" g} ~. .....~ .-:~~ ~\ ~-=
k1i ~ lI! n '" s' /" . -....", ~~, ~ ," .it,... \, ...... ~ - '
II ( II \" . "'::; - ,,,./ [Y) "~~~* ,.I\i~..,."'-' ,.:::----_:i
\ \ I.~ J 0) " - - -,,, - - rFr-"!rJ~ -.........' ~" " '" ----:-- ~
\ . I' r.:, q..,.~" T r .",5' . ~3'd ....J t:C' -" (10-- ~.......~-::J
\ ~~\ \ \ ~:t:.~ _~ _ - - fi <( ~ - ~"'''~~::-..'?::.~~
~ \ ~ \. \ ,.\'.\C\8'-i . " ",",' .",on ~ I = ---- "--=::" ,'- -.....;
I ,.... _ ,,, r .' v "- 't ,~ T . - ~ -...........
~.. \' '. . '- _~ . ,'. . "::!.:. ," ,..,.~ "'-'-- _ \'1 ' ~ -.!0 L dS --- . -- \~' . '-.... ,,~
~ ,..." ...... -\X .,._,,_......--. -----.---- - 0 . ---'
i ,.....-> ,.\ """ . - 'C'- · - - .", OOT.7 - ~":JII. ~ \ ','
j'" \;] I \ 1 ~ "\",~""_-,,,--,,,~,,:p,,"'.:'_-"'-''''-''' ...,.--,'~' 'il}dO :--..... 'itf/ '. . 0 \ \
,r.".& \ I ....-' -,,-- ,s -- ' .'
,..~ .___' . ," ."__.....--0-- ~ "''' ~ .-'\ .
l ~\It \~\ I 1.-.' ;{-:-. ';' · , /' --------- ---- /---- .,., . -- -- : ~~... ;- ..:::::..~:" \~ ;
\; \1//;;-;6 ::t>/'/-:://<=:" 1---:;'~~"~"""! - ..!) .'
~\ J~~~~/\~/:;;;;;~~t-~::~ ~-":~:..:::~~~~~
\ \\\\ /.... r-/ ..cv-' ~-=--.a-=--- "," "- \" . --
____ _ \ \ \ \ W "/~ ~ ..-/ .,~ ---- - '" 59 -~--~ - --, '; "- ............ ...........; ,:::;
\ \ \ ,\ \ \. '\"'~" N;-'i.r~ ,/// . '(;, "'J4,,,~ '----....',
\ \ >, '-. ,"'- \ \. <....:... ( '\ / _ / ' 11"", 1</00 ''''. --........-,;.--0:>.......... ' 'it $q .........-........;
. L~ ',-<'\\\ . \ '\ ~ :I)f:)Va' ,./"..'..... 0 ------ ' ",..'" .
\ -r' \' \ \' . _..as. ,"'" , "
,--_----/ ..' ,. \ ./ ""Do '. . .... .
, \ '\.\\ '~\ ~ " ,_/ ,_ r ",. .........
I, . ,\ \ .... 0 ....:-"
l '0 . '\ \' ~
- ....,,- .... ,,' \ \ ,,/ ... ", " "
" ,,' '\v' ",' ....
'.
PARKING REQUIREMENT:
HOTEL GUESTROOM UNIT MIX:
1llIlII..'
--
.--- T
i I I
WI
1oIR. t. . I . a
.... .. t I . ..
alR. .. 1 I . '"
.... M 1 I . ..
.. II I .. 11
1tlWJ
1tlWJ ...
0PP-e11IDT rAIUCNI PRO\/IDI!D : IM.ACD
WGEIICMIOUND,AIIICINO'ItOVIJED: "".ACEIi
ACCESSIBLE AND HEARING IMPAREDRODMS awl. BE
PROVIDED IN ACCORDANCE wmtALL nEAPPI..JCAIIl&
CODES OF THE AUniORI1'Y HA\IHI JURISDIC11DN.
IU.tBER OF RECIlIRED ACCE.SIal.E 0t.ES1RClClNS
SHAlL BE CONFIRMED BY lHEMatlECT OF RECORD
FOREAai8PECtFICPROJECT. AU.ACCEBSaE
tlIJESTROOMS IlUIIT BE IN1SICllNEC1Hl ROOMS
AND tHE TOTAL NUMBER lIHALL~a::>>.A.YWl1H
MARRIOTT DESKIN AND CONSTRUC11ON av1iRIA.
~
aT&VENI CRIiEk BOULEVARD
PRELIMINARY SITE PLAN A ~ --- I
lCAL&:r'-4a-G"
DI! NfZA cotJ.aOECMA.8
I..!!!!.!lI....
II' filii 11,..1, ,... H.t
llIllcla. CA '4$18
T,I: 1717) 141.1111
~
UI ...,I,llrnl .
VIlI'Jo, CA .41la
hi: (111)111-1111
.'...'.llIIu.IIII..I.....
---ci'
~
m
M ~
w
a ~
0
0: UJ
D..
W Z
~ ~
0 t; ~
~ olS
:IE It) cS
co
UJ ~ Z
~ ~
~ w
w C!l D..
j; ~
i: 0
-
~
:IE
8 ~
~ c;
0: ~ I
w 0
D.. Z ~ I
~ ~
D.. cS
..... ~
..... ..... i
:i: w
c en I
:z ~
i1S ~ I
J
I
DAre: 5-3()"()7 .
.
REV. NO. REV. 1>>.1& I
8-08-07 .
8-28-07 .
8-28-07 i
7-'0-07 i
7-12-07
8-08-07
PREUMlNARY .
I
SITE PLAN A !
.
I
DR :.!JI
JOB NO.; SHP03
~"-----'\.o...__..",.__ .
TOPOGRAPHIC SURVEy,
WARD SURVEYJNG
1729 SEABRIGHT l\..VE.STE. A
SA.NTA CRUZ,CA. 95062
PRroECT NO. 02117
DATED' 2/211'2002 thru
51'2007
GEOTECHNICAL INVESTIGl\TIO/:L:
UPI' GEOTECHNOLOGY, INC.
750 Cl\!IDEN AVE. STE. A
CAMPBELL,CA.95008
PROJECT NO. 2711.lRl
SERIAL NO. 12114
DATED: 3/11/2004
\
RECEIVED
AUG 0 2 l007
..... /'
r ~ ',J '\.,
(:!! ,,/' '\;t>,
.,' j.! I /' '-, /"'" ~
f,l.-;} )\ t/?" ,., \
\~l< ( < JA~)' ~.t "
('it' I ,,,-!J 'x '\. "'~ f
.... ' I .~~ ~ v/' '\ ,
'---' ",. J~ '- "."
~ '\ \
It+----------- .r;\ ~ .\ \
_--....!~~ J '. /x .', '~
t. " / ."t?'
~'\~/ .~':-~ ~\
~,\',
\
",l~'''.'o
~...~\
'. ,I '\
\_I.~"
\~~l{
\' ~ \
'.~' \
'-.
,
"
'"
."
'''\
'''\
. '''\
.J "-
"
'\
,\
,.-'\
J;
/~
~,^,.
; >.
.' '"
..""
."
'",I'LL>"-'lIHE! c>F'=>1Re"'r1
" .<-
\
t1A)(IMUH HoU,:>E'SIZ.E.
~. (1!:>-lo,0x>)/l0c0('./~,'J'3)+4!:>(Xl
(le2, ~':I2-10,cro)/lroo~"fl.'?~
(112, ~?2.). '12..'l?U?"I,"::A..IO.~a...209
1000 +~,!:>Q?ODO
Mp.,~1 f1 UM I-lOU'7~ 01Z-l: '" 14-, t>lXO.':209 ~FT-
BY:
"5LOPE J>..oJU-:.THEf.lT
A)((Ht.~ ~(l'-O.I)))
1+, WG..1.0'3 (1-( f."? ",~~-o.1))
(1-(1.">x ('2'3.'~)
( , -(44-.&";>)
14,e,oG..2~9", t43.e,';))~ W+~2.">O
C. (Pf"l'2..!:>O~.FT.'" (.:,O:V}'),;,',
!!
~.
.
EOl:>E,e: 01' I"AvltM\O:f.l1
-4~=--\
_ A-~"~
i'y <~~::-
"\f~~Q .~. ., 1'1
OJ . '-.. -'-
fa,'< '-~
;"'-
I'"'
" ^'
.+~;.
j
I
J
I
;' /-
/" 0)\9
o ,(I'
,,(...."''tJ.., '..:
/"~. RJ\o
~- ~, l~ ,,,,.,' .
,.\V'"
ll.','l-'t
~'" I
~~
uI~
~'.~
tl<!-,
o~
/
Sw
"':!
,~~
: \
..,
",'~
-;;
.>>
\
r~~~p~
"- Tof' Of !>. ./1,14. ~ K.
- -.... ----- -. -, -'-
FLOOR AREA SUMMARY:
1.
BASEMENT LVL: 2624.50 sq.ft. (exempt from F.A.R.)
2. GROUND FLOOR: 2641. 50 sq. ft.
3. 2nd FLOOR: a) 2281.75 sq.ft. (habitable)
bl 340.00 sq.ft. (outdoor patio)
-.-.--.-----.--.---.----.----...-.--------.---..--..-
4. TOTAL FLOOR: 5263.25 sq.ft. (allowed 6500.00 sq.ft.)
~\
J ~~
~;>
"-'",
. vJ'
4:
1
i
,
IQ
l;e
;,/
/
/
.(
g
g
->1'1'
<f>
~
.~
2.78AC. NET
P CL.
:1...
'Z'Z8.09
~k!
""'~,'i
~- 4-t"t4-wr A.-' I
'~"fZ11Plillf'~L. ,\r'
.NO,!) I ;::'>5M. "
t...NQP5 Of-'N.E..U.1S
~
X, .~'''T'''6 ____ e~~.....,.,,, fb<<. 1'0>\""""',
,r;- ;-~... C...O';~Lt\!~\NW~\<. Ml1~t';\0~ I'elC\c
...~..../
THE l'ROPOSED RESIDENCE AND THE PROPOSED GARAGE
SHALL HAVE A RESIDENTIAL FIRE Sl'RINI<LER SYSTEM
INSTALLED PER NFPASTANDARD 13D
"
.~~
~SITE . FLI\W 1/tu-11 = II_orl
/.; .. ....." ~""."""._, <"'''''"''0, ""'" '''''q
// " 'APJ.j; ~(;;(P~+1'1'!:>~,~':-47.b8:
// / . r~l<:CEl- "O(2E: .of.10Ac:m:T.~ 1e?~,C!>'Oz:;OO~~
ZONli-.lG~RHS I Mq.'O'.DP8! )~o/,;
PA~CEI. j../!'O P,A:J:;?CEL I1~P i/Dt':M-3
~!'r_~~.9KI'..!
DAVID L. BABBY. RCl\
ARBOR RESOURCES
P.O. BOX 25295
SAN MATEO,CA. 94402
DATED: 6(221'2007
/.~.. ",--
U u'~.
~. .~.
<:;..
O~ "
96'>, ..'~+,
.. !/J<
':10'
7.
~
in J'
ll.l r-
U . ()
_ncr ~
'II i) .
III ~.~
J.j ~~
> III -.J ~
-<l.. ::J <(Jl
~\.) .
\- . ~ ~..
~ ..J t-
III Ill~
{).0I:'> ::J ,
~ (}--
()~()~
il."\-\OdJ
".,1
~
o
ulli
u u:
Z~::J
lUa::..(
9zU
U) \'! ..
1U1llO
~~!
\f!N~
1i.1611ll
l-;~L
4., N :J
>- ('l U
1"'. ","
1'7' II t'2-I~O,1 11'.CP"
I}].d' ~~c:>'1 .0
~
! ~, --~ ~
--J......"'. 1_ \...J '_ ,)
~%~M~H ~/
i ___ _..I..., FtM. ~r< ~ '<7
I ..:::s; ~~- ---::- ~- + I / /J __
/ / /: /'J / / Ji!( /1/ .' H '" I I I II l : .: <= '
I, V , ~ _.... '.'_ ...... ..IIJ Ittt-I.-~ ' ; iL.L~:h L+---- I III ~ I , ; ~
. V f ILl, I ! iLL ' , 1 ~ : h [ i_ I III' I L ' _>1\ '
1\ I v. ) ;"I~'''OS. 1 ~'Pt' """'H...,.." 1___,'" LI .1..L j
U I f/ /~11.llS- r<~~i<lNoo'U>~~ ~ ~~ RH ; ;
t-' V T . i Ii .... I''';'' L
I I. r;;, · ~""tlf'. ' -0
I - '5TO~"''::;E. ~. I ,'"", . :.L., Tcf'.r<P.CE AElO\J1O- I _
L .~" un- \ I Ir7\I1 ! .,.9
~."""""'<;.!.~ WI"" C-Ea-I..--/>..F<- \~I i (j~IIUl"lt- _
= · rtl-, .' ~rutlf'."'. . ,
i lf~'ilt.~;. i ! " ~" "'''',...... '.~ - ~". C( ~~-Q ..~+ ~ ;:!1t.-1f.'"
.' 'L ....'.' roW"'"-!:> ~,
r !, .n-~ 'lj(p ',,- 0 l ,.
/ .......--,-.:.10.. t
\ ':---lll Y tl:~:.::C.!::- !; ,.;j. , _ I .'
\ ; . · !Y-,.?Jftff I I .. ...
\ : ' . .' I _-------'_._......_ .' ___, ________._.__._____ _--_ ____-+ .
_I l' \...----..-.. .....+,-.-.--....-...-. i: l .. 1fl: .
'i\! \!V,.,. PN-la.. .. . . . . I ,I ..~ l~~~
~'-'. '. l-z.tx~' . f2.Cc... ,.t:z..t"1. " CO~ ~",e. w/~t:>I/>..iJT HEAT V .' . -HIm: o. ..h." . , _
i -1!&T.'""'w ".' ~H. Clt-. -r.U.~747.5l) ~ 6~.1? I II . . l':;..."t>~ _, " '. '. l)
'. ' . . ~ I ..,.. :5L.a t;>t2., <:_' 'i"'I" .
1 ..-.'.. S.I? upt,z",l-j;,. 'Ri.' II "~'"T "0 I U 0 10 TS1P!GI.. -'-1 n.,' ~...' r~. ~
!, f'1NH i-ISVSY .lJ V . 1:0.~ 741.'':>0 Ii-:- m;T~ I . ?
I (t-''W",5~1;'!:-'" C I Lf.GH'T"'W;.E;l:.~ is'
f STIiSI;L~ ""'TVP. _.. __ . . ~
r U"1Jl6"TI!"~ '.C. .CI--"'T, ~'l>ei- F.-i-"147.1'"
I · . 'bet.aH ~>li</l:>l5P. . t.. o. '. I l... ,. .
I. -' r--- ----, ! ~NRS . i . .l'7/.,2'W!(r.w.~11-l""1>E5"'1 ~. :r~v.:E~.It'2.:lAN. 0
~ I; ~,,~t;<>ecJoellr 1).."-."'''Sf!'~~1! 1!P1..I!J.G. '.. t>/&"MI>l,CI.~l1ROC!)
I .... I .' .-.....1. r-+~,J:l~. " r'~!lI<I~ e>~m:s.NlP'!Yl!.I\S..l!l. I '
I ' '1. '1 __ I \1(,1'. ' .L.. .
I r~.g r~E.1 I ~T ' c . '~';. ." ..,,'.:'.. . ~'_' . I
"';.1 ", j .' :1. ' "', L.. h&r.i.I.:-;iR.~ <;.O~PoJ;a' '~J-;~~I--'
~. . . " I ~ \.: ,. '.. I' / ::>,.]$1. J;Gj1"-f.~ -roo (.,lc.H1'.w~ " '11P...J~. I .
. ~ ahy....lt!lICII,(-..;-" .. ". I,. 1""""- I
'.0'" "-I-1'if1 C"'e.CN e.) .. ....:.. ,I' . .'. '. .... .' I .1"XIS ,i =" I "
....., .~~' U a
. tl.!aeM" -L ili -, wP 11t'~
'~l'Il!T ,n 'rl >3 ~"l
-,,,,,,,,q II-i eHT-etllR. ':- ., __ .__ I. _ _._..
'. ..L...._ :.' , _ ... ,,-- .......c:c . '
"VB ;/ L = Co '. c,' )~"CLR.
Q V."".. 0 ..J:. ... __ '_.__...... . _->".="
. -~ [.J5,,'-\, &'. epU _.
. ~ .' ~ ~ RH; G<'UPT'fM2-P ~"
-0
~wr1"( r"lCc.t-I 5- L. P\ e "., e.ov!O; ~
, . ~
. ! II ! I i l
I 1111, I I
I .1111 II I..
+'u' ':0'__ >--._.nl~'.."'~..~_.._. ~
" "" '.. "
, I 'I 9' It ~o'- 0"
,,[" I1.Lo'l 11- 0'1 B-a -C> .
' () 1" '- 0 II n' _
~
~'5EMEJ..jT Pl-f>-..W
-'2101+ :50S'I(n. ( GRaS':>)
M.. ""'CIt__~
\
REVI8IONS IllY
T
'5
\0
.Ill J\.,
U ,{}
d'"
ill n a-.
IU u.:~
J.J _.",.
): IU ..J~
..( :J <('iP
~\).. !
. .
t- ..,.
r:L .s~
u1 ..l\l .~
n.() <t- '1
G ~ () ~,
11.. '\- J() \0 T
Ul ~
'-J . 5
~~'"
u) .... ~
d
d)t-~
. ~J
ul .c{ Oc{
riZ\)
I.!J' -
\).10
~z
"t=
u.)~ ~
t-:~:
<(~.
"'--~G ;'
/; ,<::4. j
_n._J
-7~01.o7
_ rft."~I'~d
-R.lf>,
.... '( ''':rE.'5, K
-A-2
Of _
~~~& ------------
t&'. 0~ , \17 I. 'bll
j.------- --------------------{-------------.-----.-----------
I
I
rZ>l-~-l-INe. J..~"'H;; -- "
--*-___----Y_ ________
""'x r. SI-flJ:L't:>
fi./.P.' FlJ'oT: "'-lJ
\Ill, rrr- 1"'1 00 ~hl
- ~~ . a~
-31 ~'" PR. ~ec:, ::<.,,"") rU'Wr? f"g.~r? '/.P(,<(?
'" .().. tMI- pg.~""ipl._b__ ! 4 ",.B. 1'P1-.t7t>'O'i'<-- -J:>'IoI.-_:9:-
I"~. ~'to [;I.H.
I
!~~l<JlflGt
~OOK
S5.....~.~~.)~.1I111
'21" OPtl'Gt
='h:
...'\~ ~,fx:;r'($
_ V/" _ -i 1 7!!>.~~"q"f'>HI",
II I-~~~t~-~c~_: ....~~pJ'1q{pq.
, I ' , ~; - ';'. OPHe., I
! Ii! t~ ~'J:
i I : ; I =~~ H ~ L L =~~
bw..J..L J . "'-4..
IIlIIIII;:; --. - - ...--- -- uP 120 t:>e>
. CZlCi>ij IAloe N< C.HTC1.2,HQ~. ~~~-'
'1'-011
.'r'~'
I
tlr q I
1
r
c
~.=t
~
-Q
-.
~
F.F, 6oc,I!J'~
U--~/~
--
~
~;~
I
L.I.VI Net F2-M
!)j.d-I'1~~ nREPlAtE
~a~ ~'k", D
1"'~~
J-Jooo euIUlllol&
-~ LIP 12~
:ro 2HD . Il..
-~
;1 I
-~
,
-0
~Ll
~~
iiQ
a.
5TUbY
&..:
or
t;1-$
tf.'!"
-.-
~o
~
lilVlC....-rE:;
U<-FU/lIl:llJOI TiP,
~. :-- . -, .' ,: - ' ,
-#!.. ::I4-';~l?H.
-()
-.
t-
r~~'
T'
, .
t'J,iO
-------~~""~-----
~
'it
~~G
. - -,
7 . <:lit:
G'<
1'5r.,el"'~
<i'
.
2
e
...
or,<
"-
cWTRY-
,f." 1.:i'i.o:"O
tril".. . Y --.---
::-, .:" ,,-.:~ ..,': " <.-'-:' :.,;. ".::;.{~
.-.,'."....:-.. '-,". -.."....- --'-..,
'.~.' > . ...... ,',
1'Jt.~~.
Wf-~QkIPcM.
WI"'. s;
1>-
fOr<.. C H
T-l>.~75".DO
In
..
11'~OII
--_._.- . ---.-...-..-.-.
F I J:?';5 T Fl- 00 1=2. Pr....p...J-J
'2(,.+1.";,0 "VJ.l=T.
.... .....---.......
10'-0
1<:>1-;;'
t:tI.O'1
1
~~ '500,",,"
10'51<11 fiX'!?
'l-..~c.
C5M1
~ j-.,\ ,
L/ '---
, t:I j tU.t::W:. RM
'1":>1, "0
b!saI.CIlUTE
FI<dI1 NfD"t;.
11'-0"
J2::1W1'4
~,
I
-~
.~~j;;!&~~k'P
~:)
k?TERRp..cEC I"
\ T.o.~. 1"'1.00 i
l==.=l ~x~I"~T-.{,.
f-.-...---------
i:~
80&0 5Lp. OF!..
tj
rf'-.M I L Y 1<11.
F.F. 7!:>1.S0
~f""
1&'FI~ ' . 'En
;:://",;"'5 .0"'" ~ . '
\J.EtT5~ ..-...-....
G~S Olo/L'( '-
~
I'"
2eTo
Al-':f\ -9N<,
t-...
~fo\>~
l?H;
C5
~
-t-/
I ...
lib; .*' . x -
~<tOlllH.'1>......,!;lti. i
~ l-!o.tiDllolCi. 1
~ :'9 L'U4","yllt~
, ~ ,jJ~
! '-61 . . ~
! ~"''5INK../..,
! ~ /.
i '~er.~
I
I ;, Ai--
I 3~011 i tf~c",ll! g'_oil _______
+--------------+--'--- :. -- "
~<::l
[11
--, -- -- ~_I~q~-
10/-011
F'
E3c>I!o 'SL--O. t:>~,
~:i t~
~h
r~
Fo RC H
7"'1 .QlI /loXv~T--,
It-- - T ~ ~'~.u.el'O\'!cll.--1---
L ~Lt;>Gj, '-14Ei A>I!>O>JE:
COURT YJ\~P
1~(P'-~t.
VC...t.f'<-T
-.,
~_to~, .'
R;>wK l' ~
r
7
~;-1 0
.4) I U
-.1 :--'
.:..J ..(-
iCI
l~_dl
i
I
J~
J
I
:Il !
;
j
!
.,:; ,-
:, i
k~~H:r.w~.
:1~R.V'1it
, ' I'
, , ~ .
, .
: , \
-i
\.
V.
A?
ii'
! !
1
,
I
I
!
!
"'0
~r i
,\.1"'1\011;<.1.
tt~L.O"'"
...Y ~ CD11 . .ll~l_il--ti~F
--~Pj!N-
j(pL(,;>11
_.,_..-_._-_._--~_.-
~ ~ Rf>..C.E.:'::'ee ':JH1_N~A'~
-0
111
I~
o
-
-()
-'
!:
"
-'
~
IIEV1l1lOHS I IY
7
\'J'
in J'
.Ill r-
U ,()
cnd ~
'" n-
ILl .~~
J...J-,f)
>IU..J~
:.(3<([1
~\.).
I- '.'~-3
ti. ..J to-
ut IU~
l}.(\ J ,
()~ ~ ~
1t~ 10 ()
\IJ
-~
~
GJ
.___on.
m--
.... ~
"-J .....
~~~
11.l \)
o i
~- n.:
\0 r ;:i
uS OC -<
'ti ~ \J
~;
~O
()~~
~j ;:
l: ,Co' ~
o ~~
..... ~ -
~~;:l
/ ~ \.)
-7'''7-07
-14-!,,1~oll
-RH,
- :Y~IES,KM.
-A~
Of
-
9
~
-()
-~
=~
-0
~
=1
\91
,f
- I
't+
i
o
-.
~
Cc---.
....
L__
~\?
~OW~
I
I
r---
11
Iu.:.c,
.----+-
I~'~ tI"
-10-0
---r
t~1 II 1'1" (pll
~-CI t .
I
~
~w 1Z""f "'{KIT.eM.,
I ' ,
. , '-,,~" H1.<;-TU""",,, IN/o,L.\.. >
~f'.-Lc..ONY- W/-rI~e.C,.r" '.
--eF2-.-rI~ PI ""-"''''''OM_'G.~&,~'''.-to
,_.., I
_r::.~~'!I.ol-1
F :::.=:.t'
,4!,g",,", pwrUF-e:
,w~.""~r..o...
.,-ue;.,-O-H.
,Fo'-'~t? ~K.
.....","'!
_<oj-^--;;;;:;;-' . .. . ""--~-^-"'V
-~i y b;H,t>"LCQFr< ~~;:c .., . .
Ltl "., "Y "" ,.,.Jlj
~1tt~:p t'='~G>d ./
-l,
~
l':i" I
I
I I
'--,,_-1
-
~~
EB
fwe ~H
/.'V.I':/1.
,. .. ;'r.~zl'i",~..,!> ~". . 10""
~eJ, , w,e.,. E-
' TCJ<~
'. " ~""'1"9'~1>P:1C.
o ::i'tIJ\-r-up e:\'''o!>~~'QI'I ,
· '. ."'I<lE$Z.r=-Me..~ ~
~. .~;:1. ''::';''":h.' <S.t-. "1
· 12.'~. <::<e:n :;~
. ~<3.
EXT. ~HIEL.tt1 _ .:
W,""FI.~", ~'
~
- .
- ."....0 _ _ _' _'.
:;t..... ~1'I"l>. '. .
"tlU>.
-",,'_C",
~'
; . I
~........ ....i,L,~
r" I
I .
I~d.u,
I~I'.'.
I .
I ~t;:
I ~..
I
L{
~1?PJ1 bl!!4
I ",.1-o<.e>l
'~r:J
rr-l
L;..J
5EC-ONt'FLOORPL ~N
1. 2 B 1.15 s~.fi. ~ ~OU":>E>
~o\o.oo 501". ~\f.~~c.~
2. G 21. ~ ~.n. rorp-.\..
~.
~~'"
MSTR ~
F.r. 1"'1.~
~
-$-SD.
;w:~f.0'
I
t:>IIl.H.to
tl~;.F-M:
+.. H-F\ L.L
!;P.
--'i..~,~',,,..
rnr
, &"",;;1
=0
-.
<l:
~
I
..J~._
~J~
1:':l..p.;.~.,H
~"l
1 ~.6:> II
J.
~
III
r:-i
I . I
I I
I i
L":..J
(~rzl>~Ifi- ]
W_I.~.
e,Bf:<.H f:.J!!2
+q., \+&t>
5,t>,
".j
~~ ~
~~ .........,....0.....'.......'.
-...~ . ',"
" ,"'. .'
-:',' Q
C'Ol'lT 1
I I
. I
tot_ad
~~ip
c.,,,,,,,T
e>'.o.
,
,I
I .
~ - ,
II r--- . - -..-
II I
I I
I !
i I /
I J
I-t>'t;>
FIl?~
\~~<S'teH--'
C" t
-:;r.~ -
'~..t.--.,
..w;.;.;J
r~~
4J
~
~ '~
~..:'
\,.~~~, 3~.. ........
:~
.wHT.RNI..I'l~l!;o j
l:>OWfn ~o
..d...........'........l'1~'PT
~."",~.
--n.,
...
-~g 1if&
W(II'2. ~O.TOPt.ITES
~~oJ
iQ~o~
I
I
I
@
4~<p1'
I J I
I I i
L--- ---J:
1,'.0.1
.-l--
--~"
, 1l!118
,CSMT
f'I't. :l(..~C> C.SI<\T
.-===00
",.
",JI(
,,-~-q.c--
F~::i1
8;;.j:;I~ H"?>
f.f.1c.7.'-'0
~~;
fp~~(p...",e; ')
",,,,."pR.
\"
"':f1ttl
r .Jl- J-
'~~~.I:~~,~&
1SI. Go1
!
~
-I
-;,
i
I
i
----t
I
I
i
!
I
.-'-
~j~'~ J =
.::r~,~r t _ ~
61
t<\
(O:,..T.SHiu'p
W:~.FI)tr
'f:f t. '
1
~~~T.
Wlt.I~O~
~ff'~
~J
I
-.31
-+1
-i
i
i
I
I
REVI8ION8 I BY
I
~
If)
.Ill J'
Q ,B
.n d. U\
\II .D 0-
111
J ~"
>u1:J'"
..(:J<C~
l- ~ \)~ ~.
~ -1.-3
III 1I.l.t-
{)~ G--r
()~l)~
rL,\-lf)()
.A..
! .
w '
~ ~
~~~
, ~
Q ,
~. ~
6) )-,....
ul. rf.' ~
~"1 \J
.~: -
~O
(> z:
, ...,
W:,....
I :c.. IlG
r 0;.. n1
lA'~
-....;N~
~~O
/: <::4 \)
-1-fJ7'r71
- 1/-tI~I'_O"
-I<qll-.
-'<~"E."'J k..M.
-N4
01 _
II.. ,....___.......
~
c.J,.I>.'f ~I PI!- Y IiOtH"!>
r JH~f 1-~RwQ.
/
/
/
I
~~~~motl
7
~
III
JI.l
U ,'0
d}cit
IUD, ~
J ....J ~..,.()
>Illj~
.t(::J<(Jl
. ~ \J .'
\-- . ~~
I::L -.l't-
ul .11..1 ~
0.0::1,
Q~ ~"~
11- ~ IfP{}
1 ~
~(ftt~~ ~r= I
-- --.. "-"
-_...::..-:..;....~': ..-...-"-'..... ~''':'''-~--"-.
;,':~ ~::~:~;;;--- .' .... .. r;:::::;'I";:.r~il ~.
>>" .... _. -
E1
i
..I
="1'
-'
'"
~
~t-1 ~H ~o
, ....'fl.IG(.O FIf-llSH
Vl-AY. "T.fLoe.
~~.S1l>HE
~
8m
U<'bT$'IloH~ eM" ~
=~~'f
l!2"" Mlf.l.
l~"I~f1N6J
G~IS' 1
-
Lw~'~ [~~ -r..~-ru"',::"
i'fr
'Tl\.-S p..~H
Ff20kl.T C LEV A. T IOhJ
W"eST FAc::.l'-~~
<~~,.,-'"-~.If
"-tRo II2OI-l ~t>.LGOi-N
.It
f;?wP.ArRE:oIZ- -
1=1 \'.b
i:::I. E:7
~
f l .,........--
...........
,
,
I
,
I
'r
~.................: .'. _............ . '''.' ......' ...= .~.. ..'.-,'"....' ..-. .....l......l..'.!...
' i ;-:::::::: '
, ..' L__~___ . . ~'~: n
r J7. - -. ~ ..t= --~
_rJ4 f-"'~.:J
rI-,-..,--,-~F. ~
. rJ~ L' =1-'
r4' PI\Tl.O'
r~ . .
.,cr~-
~ ,.
dl.....,
TllI' or ll.....""'LL WAL"~.....'
(~'{tiK9)
oF.'
.;.---~,
--
Rc.P\/2 eL EVATI ON
~T ~1S
~
\ rtfu..
\ ~~-+=t:
::I
~'
IWJ
;;;;;~.~'" '. .
la" ",,'
AI
~~-.'~ 1
-, Ir
I'
I'
,
III
~~~~,
""~ "'-
IISIIb-.t II-
'lI
JJ
~'_-~~~~"d'
. '.- -:-
. ~-~
--
II - f"PP~'6r1 ~Ai<lC !V1R~1Z:>~
I <l WOOP e>tIRNIN~ Fl~En.~
rc
rm
"'- tEl ..RAI1
I
-~
H. ~.., ......... ..... ....... ....... ..... '.... ....... '. ..,.,r.. l!l.df ~ILII-l0 eUfM rCRfl:""'ii=-.
~.C."~T"TO>JeCl'.p
w ..J
\) .....
.~
A III Ifi
nl ~ ~
Q !
-, 'n.:
\0 t-.....
, .J. J
W, ;Ill- '<
;v -<< ~
u..Z
~i
wO'
o III ~
Wi ;:;
, . I 116
H~lll
<( ~~
"-'-:.....~. 0.. \.
" ~ \)
-_.~.....)
.~
~
[tf.IC~II4~c:tfZ.6oDEi ~,
~~W"
- Q-<>7-01
_t4'=jL.o"
-l1.~l>.
- '(P,,-re&,K.t1.
-A-5
Of
-
:'
.~
.G\
I.
-4
~
cs
m
III
r
~'
!4
0'
..,.-'
r-
I
r-1;
C I'
,.Ill
"~~ I
~~~ J
r
I
I
d
~
R
01;1
"",
;\)
~
~
o
~
-,.\
~
G
(11
\11
~
3
\)
r
~~
.-'"
f'
"'~
~~
Fr
z:
j>
~~._-_._--~
~*
1"11I
~~
::i"
:1S
~
I DID I
mID
111111
mrn
JTrTT1.
' Ll..l...U..J
.laID
IIIIJ
[[[I]
OTIJ
U
ffi {
, 'i-\~
:~~
~ n
~ zZ:
-< !:Ill'
.- ~
II' -<
flY 0;
~
'TO
I 11:l;
_________~(i-+ ___
51 r r r I , Y~Te'3 , ~e?lbe,~cE.. ~o e;,e:.F2T AVI Leo :II
-< t:;? t:. 51~ N i
~ ~ Al $"7 ~~'2.9 Z- ~eCrNA,RT r<P. ~e>~~ '5OC?U EL t? J:2. .
I _IP "- ~'~
^ 1i' ,- t) CUPe.I<TIf..lO, CALIF. ~o'?,Ye;k) CA~J F.___ 9 ?QJ~ -
~ -l --. -
~ B<bl-J!'7w,~ ?cP~(; ~
I
II
~
I
I
2
r ~
-<
J>~
~tn
lJl
I
i I I
~-;:;;:';'\
'- -+' '"
l' ,,- '.;""
-. ()
~~
~~
~t
~f
... .
-~!{
~!
"'iij
.:i'<l>
i~
~~
::l
~
~71ol ~
?~& p
~ ~ ~
!:.
~ ,~
r
~
z:
r------
I
I
I
I
- ,--+-.,
"N
~ L____
~
'"
!
~
l:.
:
~~
\'Om
Ii
"'...
,~'"
I
- - - --- - - -1- - - - - - - -
'"
~
~
~
.{
,]I
'gi
~~
--..;~
~;J
~m
\1'-"
-13
~~
I ; i
,_-Ijr-_ I
I '
I ! i
! -
-,-- ~ i
i--
,----.----------------. '
. . _._-~_....__.._-------------
I-
i I
I
1
1
I
I
I
I
I
I
I
I
I
I
I
I
I
I
_.. _J
'\.
~- - -- - - - - - - - - - --
/ ,
/
/
/
/
,
"
"
'\.
'r----------
I
I
I
I
I
I
I
I
I
I
I
, I
" I
________..:>1
'\.
"
,
,
,
,
"
"
,
"
:YATE5 RE51t?E.I-.JCE
222Cf2 RE:'GhJ At:< T' DR.
CUP~RTI f.../O, CA 95014-
1'<.
R.
:1
"
_._H
:;
I,
II
,;
-rl
--m~----.-----t----- r
. -.------- -- I .
I '
I
-_.-..-- I
I
I
F2o~E..f<.T AVlle~ OE:.'OI~N
. "t6~~ <5Dq)UE.t.. O~.
50cpuet...) CAL.If.9507~
B~1-~1&; ~ ~(p~Cp
i
i
~
REVISIONS I BY
I1I~iot-l "'-...,. ,"",F' TILZ-:.
_~O/I~/~2." ("l)f'\.'I F'I.-tW!:'. ~HT'Gt;
,/' _'2,<& tzA~,~t.O.t..
r- tr~o e>ATr:> w/.RADIMT .r>AAF-leR.
HALL-
MASTER. BAT~
F.F. 7(P7. ':>0
" .l{'l!w.~,t:WP.~<-
~/+.TI!a.C:DXl"Ll'w". --.,
SIl~PL-~. o/l17/e,' 7JI
.~.J~T.
.1 LAlJtlG
FOYEK'
KITC.I-lE-W
f.F. """1.:'1)
~/tl TtGol:Pj( f'l.iiltP.
.~t>FL-Fl. <>/11 Tie! TJI
i"l-i'f. J..-r.
S II!! TP'E-1 '1,1 ~YP. &tt.
e C-EIL-l/o/<!o-ryr;
HAL.L
:.~_Xf...(f;
--"X1:r'-'-
/'? 1~bl>,rT5 T1'P.
.nR;O{~I'1T..
WINEO(.EL-L-AR
~ 141. ~
j1.'TH~MI>,,. .~
~wA-u::RI.'~r"",",
PEte WlL...IeEfO~T
e9 CROS5SE.CTIOI--!
'-':'~~.':":'=--~-=-~-~~~~'-~--.' .""
LrRePAgli""b~T~"'''T1;. I"~
~IL- ~Ila.lfit;:~
11'/ e,!\r JI J~T.
Wi R'?O~Tf~
~
T~.~7~~CE t.i~--'
SIlT; ~rwEO I< l-M.TOMe;F<I<:, .w. "-1 I
~~~~~~~;~L-~ ~~t
LIVIWG RH.
r.r7%.'3\
DlhllhlG t:<.M.
~"T."'R.I~ot-l ~l.I>-1/O.._
TiP.
_ '!>/+' T'~ CDX. Pl-Y""P.O/
11 TIe-" iJj FLll.J~.
TY~
~~'i. <.LV.. =.
~O.'Yl.
7.
\5
in .0
III r-
U .0
U)cl~
D
III ~~
.J-,_~
>Ill-'~
..(:]<(JI
~\).
i- S~
~ III t--
ul 't'
{).() :J I
G~ ~~
!1. ~ \0 \0
-."
-;;.
'2>-11> F\.P..1OP /I.-
71C,.r;.o
i....~~<1I.~.~
~
a>
-Ill
-i
~
-'
II)
'EJIl:.Gl',:7SU.OO -!.
HE:C.H.
'M~ FI>.e>RIc,
~F.~J.l
""pe,
11t-X.nv./R.\Po.E ~~.5'L
.~
~-
()
\U~\O
0\-\J
::z~<{
w<{U
~=z
Q) ~ ~
lllWO
~7
~-
i\-
d'>C'1sY
Wtr'.w
\-NSot
<(N-:::)
rNG
An 1.'-.
//
?,-
~
, //
.t:l-t.Y.KI-s,'SI:;>N.Tll,e <>(
'''''''2.' c.PX PLYwt:>. -ry~
//
/,
L IhlEl-J
~.'hmlQ& e,lC..~.Ci
.WI 'n"c:oyp. I!!>I:>.
TOILET II BATH W~2
71tlZily.Y.R.'
_-.I'I-I>J-lr oil Wf<.IROt-J
r ~Ol-J'f
",J(
rOYER
PAhlTRY
FAMILY Rr1.
!;;{,'I.!f. W~I!:O!lAAlL,l>l~
~ 0I"Elftf:i';>.
f.F. 1",1.">0
OTi~:'
'Wt.-,..,I\ jS't
t ~-_~~'2~ WII)J,(~
L . .'. ~rtf'.. FI~I~H C,R/otlEVi',SI!;,S
.~~
I ,1_0.11 ~.~
~CTi>;."" ::.1
UGttTI r
~. 5.741.25 II
;~c.Pk'ft~~.,'?1
~'no"",,\.
Dolo 7-07-07
_ ~n~1'_0"
-RJJ:\
-YATE-~
-AB
~
"'.,-.'r.;.;.~:
-"':"'..rAFr'
'}\.'J~.1.:",!.f.K
1'1.t Ie,' '2111:.
J'".:>" I'A!eM..LAM
~~It;.''2D~l''.lI..
.f'-^~/ltl-L"11 Ht>F/.
."/'SL-P.~"
-... I'NIR. .eiJ1.DOoR
WiTEI1P.c..~...
REC. RM.
g_.Fk,.,.r:>Fl...Il-l~o
'5UHI"NH!':
e9 CROSS SEC110f-J
_)fa ,.".....tONMClV........ ~
R1':) 1>-I'5\.>l.j>o110>l1
--.~><+-Sl'II:~ w/-e.ruu-o
e "'...... 7IOC1l0H
':>1~f..~.v.
L ~1e.'1 T'ire..'x1c"yl". ea tC.B-lklNCoo
T'1'fl e- !l>SM 1'. .
ART 5TUD I 0
1.0.'0.147.':10
<I./'l'j4e.l.~.~
I1R.iEl'1r.Gl.~
J
..1
")
01 ._
r 11 i j
r ~ ~ ~ !~
, I:l.. ~
9
"'Fl" (pl.a! .', "
~,'."w"""""~...,,:.."~.'.
..~ 'l
d',; '.. .. ' .,
'"..' .....' . .' '.
'..,i; '~...:f.'.~~..' . '. ...... '.,', .\l...
) ~; ~
.~, ".'
.t~Q
ri~
r i
, I
~d
t:1/.o'
loL.~
,
I~ Q
'~ ~
.. '"
lil ?'l
.i>;.. 9'
~ ~
B
I \
I, \
.~.
'~~.'.'
l:l~
~~
J~
YAT!~~. ~\I.~JO!:NGE
'Z?lZi!f~" tIlltrtNJ\ig1' ~..
c""rp.~:*'ll"t,u-","r"" '~Xf:,"",.."-"'-W",,"'f:.r:
;'U '.-"'C'lll/re'" """r" .~,f.r... ..."'I'l:l"",cJ',"",,,
EB.:R~"r'" . .
...-..-.....\
'--, -. . :........ -' ,~- ~"
..........-.
\:}~
F.-
t. ---b--~~~~--.:---f.. ~A
~ ~._.~
.1
\
17Llo.
:~:~
i~:~"
:' ~':t'
'. ,;j'~
":1 I:. .
....,
7La,'I ,:2:, M
!:l
'"
.~.
~
~
i '
~ I
p
;
~
10
z:
, '
. I'
~
'"';..i
.fP
; I
~
t"lt
~
j :
.~
~
~
Q
,.~.o:ai.:R.t,...., AVLI..E:.5...... .'O:E.5l~N.
'.t-t':6.!ta. .. .:~~~~i9.~p:.E..L.- ...0&",-.. ...
..~~4WIL.t.:Q'AJ:;~..'-'f:'!i.Q1'.. .
-.)!i~r;~'l1ii:;;;: ,:~.!f~:::::...._.
i
..
~.
r - - - - - - _u_ - - - - - ......... \I
~r."--'-" ~~._~ /''',:il , NOO'OO 30" 505 9< i~.
':l~ / 1Qe~....u?:gg:-~- ...j / W .~ 10&
~~r1/ ::ti>t-::--F:>~:-:/J'~- :.:?'~~,,;7\t,~ \ " , / ;m f ~~
p:< / ~ < i ' -=-__.- /!..-: --t, " ' '~~{h.. ' " ~liiJ i~.
r '/:;/ ~ - :~_.<-:.: ,~" .{l"- -'Q \ ~.\\ \ '1'" ' , / i /'
/1/'" /~>~::: _/_ '/~~.~/::> ;: .\J /) /1 ' "- g~ ' /
/ ,- '*"'" - - ~- . .....'-.---r .,:.. J I I '\' . , /
J................--"/~_.. -// -.-'--- ~/--::.-~"..-.~--~-.::..-=.-=-//- I' 1 '\\\\\\\\~! ~
/ L." - //./'., <...' <.:::.r----~ ,---. . ! J I)\\\\\'\~\\~ I " ./
I ',' -~ .-- .---..' . .-.- " ,I '!II' I'IW' (/, '" I
II' -' .: ,\~,oo"'/~./'=: __ ". _ . , ./ 1',/,'11)1 l' '\;;,-.. __/ /1
I~ ,~O ~<' '-' ..' ..., ~~/ 'j 1'1'/ I' ;~.. so;;' _--
/ I r ,,',) r' ~/.---~ ...rr:- ---~---~ ---~~ .-- .- -~-~--~..~=--:-- / ///1/11/ J '~;~ ~ ~........ ~....-----
~~. / . /' ..-. --~ .,- -".' / . "/"S'" 00 ~ /
/ V~- ;~:< , --;~--.~~":--'-::-=".-.~,~~~~~~':'-:- ~--_::~:.~::~:':/,: ,..'Y? \ ~ "~,". >~~~ , ,,/'" + /
/ t 1 &~ / _~:I'lo -<'i:- .<.e.1focK SO'h'- ;;-.. ._:-"~!... __ ,.I>~ /~ ,\ ~ ,t " ~ /" ~ .-/
a~ JL/'/~~o"r~~\'~'J-~"'/~-,,\-.~c._",.:~_J5f~\-- ,":::"(1.> \ \ .\.- ~ ~+ ,_, ' ... ~ .-/
t.;. 1 ~l':' J.. _ I _ / OrliT A1J>D / J. I \ I \, , -I' ^ ~!" '~,/ ' "';' -- ' ~
, '1-( I I '-.-r -:- I ., - -i~~' .'K.~.l \.i?~~ ~f~ -<. ,JI " , / _~-
1 \ .J., ./-.>,.---c.,,-----,.,-.-.,..~.-,_....v .J., I.' - ,..--'-'... .,~".. "')' c... " .---
+"'/ /-./ .,f, __' " // ~. j( ~ /'\' -;--'<:\" ,<, ~, ."" '.' <li~ "" /''-., ,
) //_/.y,,'./ ~~ ..:/row- ,,"I'"~''\''',/,-;-' \'Il, .~"_:f:,,, " ~,
, ~"I / / I ,/ ~'. - -- // '~+ , 1$: \, ,> \ ;if( f> /'......:;.... l' ",,/':'.
\ r' I // /;' --' .~" //. ----:/ 'I. \. .1:-..,\/1 \~\ ~ < / /0"" .",~ , )-, ,',,~,~.- .__
\ ! II i / ,/(/ 1/ // // /'./ /' ",-~!' ''\ \ \It\\'\ / 1/ i ~~"'--''', f~~,I I', / >>~.( ::.--~.':'~-.
(Ii I r / / r """ /' ~ \ "I I /'\~" C9P' '/ ~._.....{- - __T48-
\ \ 1\' I I \' "". \. -- '" \ \ \' I ,- ~ ' + "1 ' ,---..--
\ \1 \ \ \ \' \ ///. "'r~-;~ . -, --,. I \,J. ,\ \ \ \ \ <'~. / / .Q ''\ '-....';~ ' " 1" cr'~::-, . -- --
\ \ \ \\\ \ \\\\\ : {";' '*~i "'~q,. '-d \~\ '\\ \, '~~......I i~ ,~"l'-'-~r~,; ,/ / / ........
\ : \ \ I ,,, 1 I ~ <'\ \:: '\ \ '.\\\'<r / /' I 0; I' // /-.-.~:.:::---=-
t~I\\\\\\\~I\!\ ~~ ~ \\\"""\'(' ... \: ~I Y' ,><"---.-:~-:.:-.
I ; I il I', \ I I 1 -.. \ \. \.', '- -" '~, J -. '. .r / // .~.~., " . .' .
\1, I I~ I " \ 1\1 \~ '\.'.',' " /; . h- .Id,. .-.-_
\ I 1 (~ :tl I \ \ I /, \ ,'\, ~'" ,,'\ ',"- ( / I 1\ / ~ -' - - - -----
\1\\ ! \ ~I \ 01 'I' I'll .-".,. ~ : ,I \ ~,~...\-<\\\\\\~~,\" t~ ./ 'II L____L \r'/ / ,'; / ~~,::,=-.:__.,.-- -' .
I " jj!! I I \ ," . '\\. '. 'i'. \ '\ \ " " , 1-- I ' ,J
11:\\:s:i\I" II:,')~, '. \\\<'~\",\,'~ / \ \1 I;,'" --.--...-.',.,
I , ,PI I I I I" ~ . \ . ~ ',\ ,'. " . I 11 i / '. - ..-- --. --
\..,1 tall" I i 111m \:'" '< ,\ \'\.\"'" \ \_---1<I~1111 II -------- -..
~i'\ !:il \ '\"~! / / :1" ~~.':::>::. ,,'" /..<:,\~ ~\..'\".~,,\~',\'\. \../-, '~'.' \\\ "\';-~ -.-.---.,~.." \
~:' "I~t 1//, ~';/g'~ . / i\, Q ,'~ "-:,'\,,",,'\\ '. 'I' \~J ---...-- ,
I \, \ fzl i ~ I " I I / \p D,?i'- ~:;' v 1~ ~ ,\ ,,:\>,\.( \ \, ~ \ 1\ \ 'f I, .' ,,',
I \ 1\, \ ~i I;,' I : 1/ it / .~/ i"-' <>" ~~g <;? ," / ~I j'<,,\ \\\ //~' 1 \ \' \1 \1 r""'--;'" "
, ,I \ : ~ i : II J' :;;1; / rI ,I 1.0 -%" ~ " "" "'ii, '0 // //. ;.....'/ 1\~\\\\,\t\ -, "...\ 1\\ \ \ \ \ , \ '\~~-~\ \ \ '"
! 1:11/)',' I~ 11/ "~/~" ' ".." '-, <ll_ ~-- ,~/ \\\'\\& ~J 1"\1\ \ ~" ,
"11/"/,/1/ II. /111 ~./\~', '..., "~__/--- ./' .'.-/'>,/\.....\,,~~\ )./"\\,.'\1\\,\; \ot ' '"'' -..-..,
, I I : I' I I 10 I : (J ;/ ~>" ,~ '... _~---~ _- '" -- ...~,/ ~ ClJi"'! / \ ' ('... \.1 \ \ \ \ \ \ {It 1\ ' } "
)/~'/i/ 1'/'1/111 / !....III\~,.',~ .":-..'. ~.- ./.-- ..\ '~/'f'>-'2.' \l\~I'\\'~III\ '~Q~"", ",
i~ /~// /;'jJ / ;' / // II r '/it///~,~Q.., . ~:~--' --\.. ~.-. ,=-,/~<==_/---,",,~, '; :\Y:,rj' ;\ ,~'" ~\./ / \~ \\ \ 'i!V',dl!r \~ 'f',-.. ,", "'-..
:'/J:t/////II.I\/I/~'// I ///,,' ~,~> :'-.. -.' 1:. ./:// ,-' ">l'\\' \ 1,\>\' .,y\\\\,\ \J\\~\i''i,''<i;''~ ',> ':t.,
I / 'I I I I I I Vt, '8 , I k <. " "...... _ -- __ -- '\ \ ~ .--" \ (, ('.... \\ "I \ ,\ " \' ~ ,....\.. ~ ,- "
r fr'"' I JI ,", I I 'f::! I G- ' . - '.,. , ~ -.c ,\ \ \ I I" 1"'\,,' \ , " ,- ~ -..
I 11// ///1' 11,/<10// ,Ii, I / f-->\\',' '..." __ ..- --__- - .,I.....~-j__...~ I ..,/..,......l.c:::::'_-~-:~_t=--.--.......,' \\\(" \\\\~ \\\\I\\\:\~\,....~'~~'~~~,~", )-" ''-,
( ;' J~I / '/f;;y,/ / ,1// / /j,-/ I Ig/ '\ ~ '~ 7~'~F'SCOp~~_- :. ~Jo ,_... -,4:-.. \:..- -.fP\ .J_-" - ~ ~\ -\ \ \\\~~ ~ ,_ /-;~" ~\\.. \ \ " \ \ \\~\~~;\ ~~\,' " >... ~" '-..,
'/1111~2'i/ 'I' '1'<Qi: /,\-\., 'Gl) Q f~J \\\\1'\\/' ".""'\\\""'\\.''\,''to'~', -",,' :t', '>.
//,1//';'/1//,////1 /1:;///1~~~'0 110\ 1>-)- i~ ~- \\):')\'~II\ r'~)\\'\\I\\'\\\\\'\;\\\\':" ", '.4:;"', '''\ 'b.."
~e<t///////!/// //~/// dt //~"'~--"-'" ~~ / ,~f.l /}!~\: ~\-,/' ",i\ \\\\\\\\\\'~~;~~~~~;~>" \ "'&'" \, \ ",
'/II/t:-;,,"/, //11/, , .,/.~ ,'---";...;, '",-- Jr- ,./ IF rs-/1):11 _--l\./\\\;\\,'\\II\\I,gll'(''<>'', '\ z' " " "
I I r I /..'1 I 'I J / I f;}/ I ,./ ..... ..'7\. ~~, 1 \)j ! ifi.. I I , ) ~ \ / "r:\ .\~ \\ \ \ I I Cf 'f. , A ' ''\ \ '\ "
II////V-//;//! ,~jAr:// II~/'",/~~-, ''::'''~-'.'~>~~----,\U. Q'" .J/I~/ ///,\\ (" \~_ ~\\\\I'I\:il(,t~~;><\\\\\~\\, "
I f 11/11,11: / j", ! 1:ft'1 ~----__.,',,~ -..Y. ~"" --e.r , "/ { I ,{ ~\\-\---~' \ ~I\\\\I\I \"1-.\ \ \ 1 ,(j, , ,
/11,',1/'//1 '//'" /;.=11 /..----.',' J~, 'S(~' ~w ..<~/ /'//1/- I I-- '\ \\ \\\1//"\\1 \ \ \1J1\, ,
/A/;, '/(/~;/ //>// i~:l/;~:>< .-:.=:...~ ,~:.<~., 'i" ~::~:j;:-.~;~:,"~JL-,,::'~~~.~, ~,~~~/j/~f. / /~\"lfs:..\;\\ \ \11: \ i \ I \ I, ' I \ \ \ h \, \\ \\"',,""',
,/1r,//ctf/' 1;/%///> '~/~::///~1.j:'I','--'_~:e.>';"","~,t<~:~':~~i::=~-~=:..~~~::------:.':::; ~>>V.E'/ /)I/\/\...'1:~.~_--~,/I~ 1;1!)/lli01/1/ \ \\\1\, \\ \, "',."","',
1/ ,~/; / I ,I I ii (I r/, -/ ,\ \', ' 11\' '. -'.- "---. ..--.::=;..,....'- -' e 0-/ ',XI I ~I /;. \ \" '., ~ '
// /'/J~~' /1 ,~/ I//I/,/ I iil// .-,\\ ,', '>, '",_----.~~.._---,..==::-~...--.////// / . II .'If \ , ,,~\ //1/ / II~\ \ ",," ','" "b..
, , V,/ J/ I / I I I '/' / /. I I .ff I ' ( ,'\ \, " '~ - , - , --. '. I . -' ....n'~, " '.. / / ;1A __L --'d- ~ ~ J / / ,I I I /1", \ \ \. ' " ",,~ " "
ij/'i~/~/~/ ;;:;;~/;-;~~>;:{~/)!.( - \,~.~:,i~'-:: =~-:--:-~:::_-.=f-/:~L ~ ~V ;// .:.--. ~.~. \~!/11t~;I!rI(-~; \-?~;~~,~,~.:~~;:~"
/ : )f"/A:' ,/: / I 1/ 1,/ /, / // D) \ " ......"" "'- " , "-''''1~'/ ;~2C:: .;:, / ~I / _-'- 1\1 \' \ ' ~ --,- --'~......'.z" "" ",
Il/Y',...,... 1/ / // 1111/ J / / / lill- 1/-. .. --'... '-, " ,7--.,_ -.---.., - '-- "'., -'C _ _ " 'i i ////; / -- ----\ I 1\ \ \ \' \ '"--..- ."". , ...., ......... '.. "
, ,I I II / I J ' ' I" I I r I , " I<l.', '. I' - - r r ,'.. - 1 -. ',' " -.. "
~fI'..v/>;-l' ///////// //// Ii- :..'=r'<, ,'~'---R~~"-'-,:",::'--"""---,,~' '..0___.,_..., .--. ~;r ~1,>_(;./// //\ ..~ \ \\ \\\\ \\,':~-~.~:.:~<\.~'-.. "",-"", ",
~l~//~// ////>///////1//1/ )> ......, ',---..~~'-'=:--::-= ':..-. -:=?i---{~~=::7j:'----"- -' -;;:.~/.////'" .\., -- ~+1\\\\\\,\\\''''-'' \"'~-'-.'}.."\"""'......"'" ',,', '\
/J /~~ / // / / // ,/ 11/ / / // / 4ft _II / ~ .......----_ -- --~ ~~--- ----.----~_---.;.~.:-_~;~-----~-------.--_---- ,,/ ./' ,/1 \ ~.......\.\~ '. '\\" ',"~, '\ \"""'" , '\
/ ''1/ /~:~/~//,/ /.~ / /.1../ / / .__. '// P -"<>e,'_ -..::.=---:--::::.'f.....:.:l:,.---.F...':'-- --- .,- --.=--_/ ",.</ ".,..:.__ \,e1s----- ~ \,' \\\ \ "" '. ",,_ "', \, \ \,\ \;"" "'" \\'
',A/ .:.-- ~/ /. .... /o'Y / I / / ./ / ~ l;f . "" .---.., ---.. -"---..._ -- ,---- ---.. ,---. -//' >"" ~ t x.r.. \\ ,\ ......, "j \ \ \ j\\\ ~ '" "\
'f/~/6-/:>/</.~//./;//,>h/ / ~ --- . ~:--- .' - -, '>'~~--:2. -':==-=-~~~~: =-::::..~.~;:?J.~...\;i/ // \ \ ..' ~,~\\\:"'\ Ii! ! , \ ,\\,-.....',,'
,....1/ .' . . . / '. . '.' ',1 J \!J "~~ ~'- --------~ ,~.,. ~ \ /' ~\..., .' I 111 '. '.'"
~(.:.>..<~/>////>/ .' /~'/ z ~;~ ---'---..-....-..-.~~>--./ ..y:\/'//:"'/"'\' \ \! \ : i I i~{,;'<\\\
f~~'~~~~:'/_:;:~~<R;:'-,' // i ". ~ " SE1Bf;6K ,titi FROM - EDGE OF ,/ -,/' \~.\/// \.<,); lp\ \ \ i\ I i \i ! ~\~ \ \\
~t<~<"6f::///'/)::/-,..;/ . i.J, _I:"" - 50'" / t. """ STRe,i;~:rBi;- ,..,./',... /)/ ~II' I:, I \ml~'\ \
~"/:'-~'~--,,~'>'/'/>~~//..~/.;." --\-\\".,,/ /:~_~"_,,_'r-_iop~6fiLOP"C'--~'-~-~r...-....<;:::::~.-...~.."_..,.</ - \.----::, / _",,// , 1\ : I I:;~' ,~\ \
~: -_/ _,4..../',~~_ /" // ..../~, ".....,.... 1',',..... /" -<~ ("; -............... "\ ' 'v"~ I I! I I~ ~ ~ :
~ ---::....' // / ..--,. - -.~" ~-'~_...._.--".--~.__.-;.::::;.....-- ,f '<', " <. '. U \. 1.1 \ ,;0, I
~ ...':.-,;;;:-::...>'" ---=:-::-L.O'---- ~" "" /) \~,\ \\\" '
---._/.-- 'I L1Ne---_ ~ " ' . /.., "-...
/' /--~ ---- ,,<. "'-.
:::=:j~~~.- ~... / B)0E Qi'0,iiii;;MBEO / -----~--_.,~'-~--..-- "\'~" ~
"/:" """
01 {';'.... ,
(^'~ "......... ',,-
-'......... ,
"........." '",-
......... '
"......... ',,-
......"
"
:>>
z
~
p
,
(I)......"n.
-lZ 1:10
Z<H
o "
z
O':Pn-iC
~~m~~
~~5:(/1
n~~~~
oz ...
-O>OZI
....... r.'D 0"'"
~(J);;:;Xltn
o~:2~~
.,,0)......."0
-lciG;:!h..
XXI OD
....... JooZfTT
:~~~l;
J>o7.oo<
:(ri~:t~
~~~fl10
-1zn~
~~~~~
'-i> 0
n J:lOZ
fTlVH"Q)-l
::~11:~~
HZITI.....-l
'TlfTT-lZ
.....0 l'T1-c
~>~?~
. 'HO
fTl~~~
zomm
o. ..."'0
-I gg;
~ ~~
~~
~; ~
~; ~
~~ ~
~!!
o ~
o z
:~ U1
~3 i
>VI
~-l ~
~~ ~
~
~
".
"
~
0-10.-..... X
E~m~~~
U1~~~O~
~~~~~~
~:Pb~~
~~~~~~
::o>r-_" m
~~ii~~
mm 0 z
roc.no
R JJs;;::::
)> X1>mm
~ ~-1-t-l
o ~:t~~
~ :;:~
~ 8ffl;:8
i Il~
~;;;
~~Q
~;~
COO-t
"ON<O
00 """'0
". DO
n:~-t~
~~~;
:to
_'--H
.--"."
HVI
~:~
;~!
~~~
~~i
Z-l~
~~-l
~~~
'"
......'"
~~~
~~:
g.."n
~il
o~o
~rn'"
!I!
~~o
~g~
z
>nru-<
'tlCtu)>
%"'01\)-1
m",m
~:SI\.lUl
!g~~
~o ~o
OOD""
~~i~
~~
~;
~~
~o
m
~
i:
0'--
>.
~VI
m.
~
'"
0'"
~:
:~
~~
~~
'--C
~~
VI-<
~~
~~
rhg
il
<'IV>
"..,
.--".
HZ
~i?
~~
U1......"Tl1ll
-iZOC
~~~~
~~~~
~~"'O~
~i~P
... "
1)3:0
~~z
me-I
~
'" ~
C/J ~
~~t;; &i ~
., ~
t>J .
"'l ~ "l ...
i:l
~
~
YATES PROPERTY
222'12 REGNART ROAD
CUPERTINO, CALIFORNIA
WARD SURVEYING
622 SEVENTH AVENUE
SANTA CRUZ, CA. 95062
(831) 425-5005
(1001 ~ elliIlilg eIMIicn
&~IN" ~ ",,,,,,,w^<"t- t.-1i''''1Ot<t:>
24-
__ ~ diedion of flM/pM:onl of slept
H.P. _ligIIpoiAl
1lW'" 0 = rain waIor ftader,(dolinopcuQ
121,
o =6'naciai1lnpllllliogbod
IZI =6' ciai11n haIdBcap&
(~) rMZi<lHA<... "r",,~, p.t..
- -'1'_p.y.c.pipe,_"""" - =.'saidp.y.t.pipe,_
I....,. .......... ..................
.-- .. '1' portnIIld p...c. pipe, hoklo down, - .,,' Mi. r~'" "'I""'
In 1'-3" Rnch; """" IrIrdI wiIIl tlOIo..1a1dIcape laIlric
1Ild.... ciai1 rodt SkJpe.. ciai1. noW.
;:;: ;: -= ......" chInage pipeIirigalion ine
100 . pII'lpDlIId eIMIicn
8.0.W. =1laIbn of wall 8.0.5. = BoIIomof sIep RIM ~ oIevaIion aI.....draIn
T.O. W. - Top of IIIliI T.O.S. = Top 01 sIep F.F.E. ~ IInlohedloorelovalian
Gndoog-
1. VIoIIy.-.g.-il...IoId....IIring..~D
"_"'"LA -....-.a...-.
2. "........oI.....ll1d..... Dbe....- bJ LA
.", l... J'....".
3. lIIo~io_"'__....IIIll.
..............,........_itpooilioo....
..............io_.....__...-.
NoIft"l.A"'._-*'ll_"-oI"'_
-~
lIit........_1Il......,bJ_SoIvo,ilg.2I14oll2
'.......fl1J_"".1'-
~T.l!.,. """"'B
- ....
~ 'Po j i:-
., · ~ ~ - r /
= ~ ~ ~
I ,<<" ---- "0'" ]!) / f II
"""'''----~-------- -- ---1:""'------___-:------_____----.. '\ / / /11' ~__
/-''''k___-..._____~ --='-~~ I ---" --------, \) \ / / / / ///( ~ / r
em - em. ~ . \ '\ / __ /'"
I - I . \ . I / / / (/ ( ,/
/ ~,. \ / / i ! / ( ! I \~ /"
I ~1 ~.., ~, \\ .) / / / / ( ! / ! I ~r~___________
/, . ~';;,~~ I! / / / / / / (~_
., ::-:Jl11II, I I / / / / j
"'r :'-~="",", ! / / /. /./ /
~ / / /;, /
/ / / / / / /.1 U,,"~ ~o'(.
,/ / / 11/1/
/ / I // / / /
/ti,//// /.
/ / ~ . / I
/ / //! j / I
1./
<(
"','(.'.(, "" I'1W -- ~11.",P
""Y.'4 ..". VlIr.. 7.'1../J17
HlbIi~r I'M.. '" 1"-'1'
I,..........r ",,,r,,, 2'-'"
&fZ,6-171 iJz;. " ~N.P6~ I'VA~
- . L-.,.-
/
/
/
/
....
__tA _
/' I ............lIlIt)--
/
..../
- ..
Saii.. i,... ,'...ell
_.,. ~.w.
-.-:?'" .----
.....- - ~/ :?
-~'"
- ..,. ...~...?
-
(J-
\
... \
.~ ~ \ \
\ \ \ \ \ ...............~1e
\ \ \ Y'
YAT~<? ~It>.tla
'Z~VlZ. ~~r 11''''''''
v....W-T"'I.?, C,,", 14--1+
'''.'''f r.. ~T...n#.
r-HP VII '\IJio"~ tW-p.
..........( p_,..r6JI. ~ ~_
~"'H""r(b#~
G2