Loading...
U-2010-03b _ _ __ OFFICE OF THE CITY CLERK CITY HALL 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 C U P E RT I N O TELEPHONE: (408) 777-3223 • FAX: (408) 777-3366 Febi-uaiy 18, 2011 Re: Petition for reconsideration of the City Council's January 4, 2011 decision to deny an appeal of a personal wireless service facility at the Results Way Office Park At its February 15, 2011 meeting, the Cupertino City Council adopted Resolution No. 11-022 denying the Petition for Reconsideration upholding Council's original decision. Please call the Cominunity Development Department at 777-3308 if you have any questions. Tlze decision by the City Council above described is fina[ effective February 1 S, 2011. The time witliin wlzicli judicial review must be souglzt is governed by �1096.6 of tlie California Code of Civil Procedure wliiclz is 90 dctys following tlze above effective date. Sincerely, �`� Grace Schmidt Deputy City Clerk encl: Resolution No. 11-022 cc: Trillium Telecom Attn. Dave Yocke 7901 Stone'ridge Dr. Ste. 503 `� Pleasanton, CA 94588 Grace Chen 10192 Imperial Ave. Cupertino, CA 95014 City Attorney Community Development RESOLUTION NO. 11-022 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF CUPERTINO DENYlNG THE PETITION OF GRACE CHEN & GUO JIN SEEKING COUNCIL RECONSIDERATION OF ITS DECISION TO DENY AN APPEAL OF U-2010-03, EXC- 2010-04 & TR-2010-31, A USE PERMIT, HEIGHT EXCEPTION & TREE REMOVAL TO FACILITATE THE DEVELOPMENT OF A PERSONAL WIRELESS SERVICE FACILITY AT THE RESULTS WAY OFFICE PARK WHEREAS, on January 4, 2011, the Cupertino City Council received a staffreport and recommendation to deny an appeal of a Use Permit, Height Exception and Tree Removal approvals to facilitate the development of a personal wireless service facility at the Results Way Office Park. WHEREAS, the Cupertino City Council held a public hearing and at the conclusion of the hearing denied the appeal filed by Allen Wang, Grace Chen and Guo Jin on a 4-1 vote at its meeting of January 4, 2011 WHEREAS, the Cupertino City Council's decision was within its discretion and made at a properly noticed public meeting. WHEREAS Grace Chen and Guo Jin requested that the City Council reconsider its decision under the provisions of Section 2.08.096 of the City's municipal code; and WHEREAS, the City Council has considered all relevant evidence presented by the parties at all hearings, including evidence presented at the February 15, 2011 reconsideration hearing. NOW, THEREFORE, IT IS HEREBY RESOLVED AS FOLLOWS: 1. The petitioners' Reconsideration Petition is defective on its face in that it does not offer proof of facts as required by Municipal Code Section 2.08.096. 2. The petitioners have failed to offer any new evidence that there are any feasible alternative sites to the project that are less intrusive. (See Municipal Code § 2.08.096(B)(1).) Specifically, the City Council detennines that: .� a. The City Council's decision is supported by findings of fact attached as Exhibit 1. b. The fuldings of fact related to the City Council's decision were supported by substantial evidence in the record of proceedings. 3. The petitioners' Petition for Reconsideration of the City Council's decision of January 4, 2011 on itein 9 is DENIED, thereby affirming the original decision. PASSED AND ADOPTED at a regular ineeting of the City Council of the City of Cupertino this 15 day of February, 2011, by the following vote: Vote Members of the City Council AYES: Wong, Santoro, Chang, Mahoney, Wang NOES: None ABSENT: None ABSTAIN: None ATTEST: APPROVED: � /s/ Kimberly Smith /s/ Gilbert Wong City Clerk Mayor, City of Cupertino THIS iS �0 CEAT{FY THAT'�HE V�►�'Hll� � OF ORIGINAL QiN FlL� �iv TFiRS 6t`FI�E ATTEST - . � 3L---� 2(�-�L CIT1' CLERK OF Tt�� GI CUPER !NO ' f ,. BY ClTY CLERK EXHIBIT 1 . CITY COUNCIL FINDINGS IN RESPONSE TO PETITION FOR RECONSIDERATION Cupertino Municipal Code section 2.08.096 states: "A petition for reconsideration shall specify in detail each and every ground for reconsideration. Failure of a petition to specify any particular ground or grounds for reconsideration precludes that pai omitted ground or grounds from being raised or litigated in a subsequent judicial proceeding. The grounds for reconsideration are limited to the following: 1) An offer of new relevant evidence which, in the exercise of reasonable diligence, could not have been produced at any earlier city hearing. 2) An offer of relevant evidence which was improperly excluded at any prior city hearing. 3) Proof of facts which demonstrate that the City Council proceeded without, or in excess of its jurisdiction. 4) Proof of facts which demonstrate that the City Council failed to provide a fair hearing. 5) Proof of facts which demonstrate that the City Council abused its discretion by: a) Not proceeding in a manner required by law; andlor b) Rendering a decision which was not supported by findings of fact; and/or c) Rendering a decision in which the findings of fact were not supported by the evidence." Original Petition The petition for reconsideration consists of three pages. Reconsideration of this item constitutes the fourth full hearing of this matter conducted by the City. The grounds for the reconsideration are siulunarized below. It should be noted that three out of the four claims do not Uear any relationship to the criteria referenced above. The City's findings of fact on each of claims a.nd the criterion are delineated below. Findin�: There are three claims that do not bear any relationship to the Reconsideration criteria found in municipal code section 2.08.096(B). Petition Response Screeni�g landscaping for the monopine Petitioners seek to add and refine needs to follow strict a�sthetic guidelines. development conditions that have already We request the addition of a condition to been adopted by the City Council the approval that the "additional screening (Attachment K) which does not relate to trees at the northern propei line" will the reconsideration criteria. Petitioners' conform to that of the approved interests are already addressed by redevelopment plans of the Results Way Council's added condition #6: "require that office parlc and any revisions or tree planting conform with the approved modifications of those plans. Landscape development plans of the results way office screening plans are unclear and should be park." In addition to #6, City Council . open for public view. added six more conditions pertaining to . landscaping. Staff has already agreed to allow Astoria Townhome owners to informally review the landscape plans when they are submitted. Request to add a new condition to the Petitioners seek to add new development approval requiring applicant to pay condition to City Council approval, which $30,000 to the Astoria Homeowners does not relate to the reconsideration Association for additional irrigation, trees, criteria. There are no legal grounds to add fencing and related matters connected to this condition. the visual screening of the wireless facility. We are talking to the property owners of There is no evidence or facts that relate to 10340 & 10420 Bubb Road to explore a the reconsideration criteria. The request lease for a cell site. This alternative site for continuance should be denied. The should have similar criteria as compared to applicant already evaluated 10420 Bubb the approval with less impact to residents. Road in its alternative site analysis (PC We request additional time allowance staff report). Applicant cited a lack of room and proximity to the freeway where AT&T already has coverage. Findin�: The petitioners have not offered any new evidence to demonstrate that Monta Vista High School has become a viable alternative site for wireless facilities - Cupertino Municipal Code, section 2.08.096(1). Petition Response The Fremont Union High School District The petitioners have not presented any has recently entered into leases for cell evidence that FUHSD would be willing to sites at several other high schools in the consider Monta Vista H.S. for cell sites District. More than 5 years have passed again. The 2005 City approval of a since AT&T approached FUHSD about wireless facility at Monta Vista H.S. Monta Vista High School (H.S.). Given expired in 2007, so the applicant would what has happened at other area high need to go through another public schools, AT&T should go back and check entitlement process again. A request to about antenna opportunities at Monta Vista place a wireless facility at a school site is since District criteria may have evolved. not before the Council. OFFICE OF THE CITY CLERK CITY HALL 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 C U P E RT I N O TELEPHONE: (408) 777-3223 • FAX: (408) 777-3366 January 6, 2011 Re: Appeal of an approval of a wireless service facility on Results Way At its January 4 ineeting, the Cupertino City made the following action: Denied the appeal, required the conditions as recommended by the Planning Commission, and added the following conditions to the Planning Commission resolution: (1) plant additional screening trees at the northern property line to screen the treepole from the astoria townhome development; (2) require berming and plant at least two 36" box, coastal redwoods blue aptos variety on tlie berm on either side of the monopole to screen it; (3) improve irrigation around the trees to ensure proper growth; (4) remove and replace trees with dead tops; (4) adequately maintain and water the trees in the parking lot; (5) re�quire an annual status report on the trees by a certified arborist for three years from the date of the tree planting; (6) require that tree planting conform with the approved development plans of the results way office park; (7) allow a monetary cap of $75,000 for the berming and tree planting required in the added conditions. The Use Permit conditions are as follows unless amended above: SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY DEVELOPMENT DEPT. � 1. APPROVED EXHIBITS Approval is based on Exhibits titled: "at&t/CN3242-A/November Drive/Results Way/Cupertino; California 95014" prepared by Jeffrey Rome & Associates, Inc. dated 08/31/10 and consisting of seven sheets labeled T-1, A-0 through A-3, A-l.l and C-1, except as may be amended by the conditions contained in this resolution. 2. NOTICE OF FEES DEDICATIONS RESERVATIONS OR OTHER EXACTIONS The Conditions of Project Approval set forth herein may include certain fees, dedication requireinents, reservation requirements, and other exactions. Pursuant to Government Code Section 66020(d) (1), these Conditions constitute written notice of a statement of the amount of such fees, and a description of the dedications, reservations, and other exactions. You are hereby further notified that the 90-day approval period in which you may protest these fees, U-2010-03 January 6, 2011 2 dedications, reservations, and other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest within this 90-day period complying with all of the requirements of Section 66020, you will be legally barred from later challenging such exactions. 3. COLOCATION OF ANTENNAE The treepole shall be structurally designed to accommodate the collocation of additional antennae from other wireless carriers. The co-location agreement shall be at market rates with reasonable compensation to the mast owner. 4. ABANDONMENT If after installation, the aerial is not used for its permitted purpose for a continuous period of 18 months, said aerial and associated facilities shall be removed. The applicant shall bear the entire cost of demolition. 5. EXPIRATION DATE This use permit shall expire ten (10) years after the effective date of the permit. The applicant may apply for a renewal of the use permit at which time the Planning Commission may review the state of wireless communication technologies, camouflage techniques and maintenance to determine if the visual impact of the aerial facility can be reduced. 6. TREE POLE APPEARANCE AND MAINTENANCE The applicant shall use a sufficient number of artificial branches to obscure the appearance of the panel antennae and any associated mounting framework. The top portion of the tree pole shall have branches of varying length to give the tree pole a conical form. Panel antennae mounted away from the mast shall have needle covers to blend with the green foliage of the artificial branches. The mast shall be wrapped with a falix bark and any antenna mounted close to the mast shall be painted brown to mimic a tree trunk. The foliage shall have a mottled green coloration. The building permit shall be reviewed and approved to the satisfaction of the Community Developinent Director to ensure the above condition is met. The applicant shall perform regular maintenance of the tree pole to maintain its appearance and obscure the panel antennae from public view. - 7. EQUIPMENT ENCLOSURE - The base equipment enclosure shall be constructed of high quality materials and/or be screened by appropriate landscaping as determined by the Director of Community Development. The final enclosure design, wall treatment/color and screening strategy shall be reviewed and approved by the Director of Community Development prior to issuance of building permits. 8. TREE REPLACEMENT The removed trees are to be replaced with three (3) 24" box Coastal Redwoods in the northwest corner of the property. Final locations shall be reviewed and approved by the U-2010-03 January 6, 2011 3 Director of Community Development prior to issuance of building permits. Applicant shall provide a letter from a landscape architect, certifying that the newly planted trees are in good health and the irrigation system is operating properly to maintain the trees. In addition, the final landscaping plan shall confirm that the existing irrigation systems are operating properly in order to service the existing and new trees in the area. 9. TESTING OF RADIO FREQUENCY (RF) LEVELS Radio frequency levels will be monitored and tested annually for a period of three (3) years from the date of the final occupancy approval. The result of these tests will be made available to the Planning Department and the FCC for review. The City reserves the right to perform code enforcement actions and/or revoke this use permit if the results show RF levels inconsistent with the federal standards. Please review conditions carefully. If you have any questions regarding the conditions of approval, please contact the Department of Community Development at 408-777-3308 for clarification. Failure to incorporate conditions into your plan set will result in delays at the plan checking stage. If development conditions require tree preservations, do not clear the site until required tree protection devices are installed. The conditions of project approval set fortl: lzerein may include certain fees, dedication ��equire�ne�its, reservation requirements, and otJzer exactions. Pursuant to Government Code Section 66020(d)(1), these conditions constitute written notice of a statement of tlze amount of sucli fees, and a description of the dedications, reservations, and other exactions. You are hereby fu��ther �zotified that the 90-day approval period in which you may protest these fees, dedications, and other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest witlzin this 90-day period complying witlz all of t/ze requirements of Section 66020, you will be legally barred from later clzallenging suclz exactions. Any interested person, including tlze applicant, prior to seeking judicial review of tlze City Council's decision in tlzis matter, must first file a Petition for Reconsideration wit/z tlZe City Clerk within ten days after the mailing of the notice of tlte Council's decision. Any petition so filed must co�nply with Municipal Ordinance code �2.08.096. Sincerely, , C�� ��.`C�'' � - �-�--�� Grace Schmidt Deputy City Clerk cc: Community Development Trillium Telecom Allen Wang, Grace Chen, Guo Jin Attn. Scott Longhurst 10170 Imperial Avenue 7901 Stoneridge Drive, Suite 503 Cupertino, CA 95014 Pleasanton, CA 94588 / City of Cupertino � , , 10300 Torre Avenue Cupertino, CA 95014 (408) 777-3251 C U P E�T 1 N O FAX (408) 777-3333 Community Development Department September 16, 2010 Dave Yocke Trillium Telecom 7901 Stoneridge Dr., Suite 503 Pleasanton, Ca, 94588 SUBJECT: PLANNING COMMISSION ACTION LETTER - U-2010-03, EXC-2010-04 TR-2010-31 This letter confirms the deci.sion of the Planning Commission, given at the meeting of September 14, 2010, approving a Use Permit to allow the construction of a personal wireless service facility, consisting of a 74-foot tall monopine with twelve panel antennas and associated base equipment; approving a height exception to allow antennas to be mounted on a monopine at a height of about 67 feet or less; approving the removal and replacement of up to four Coastal Redwood trees associated with the installation of a proposed personal wireless service facility, located at the Results Way office complex, according to Planning Commission Resolution No.(s) 6604, 6605 and 6606. Please be aware that if this Permit is not used within a two-year period, it shall expire on September 14, 2012. Also, please note that an appeal of this decision can be made within 14 calendar days from the date of this decision. If this happens, you will be notified of a public hearing, which will be scheduled before the City Council. Sincerely, � .� � � - ---- - colin Jung Senior Planner Plannulg Department Enclosures: Resolution 6604, 6605, 6606 CC: ECI Two Results, LLC, 1301 Shoreway Rd, Suite 250, Belmont, CA 94402 Allen Wong, 10170 imperial Avenue, Cupertino, CA 95014 g:/planning/post hearing/actionletterU-2010-03,EXC-2010-04,TR-2010-31 U-2010-03 � CITY OF CUPERTINO 10300 Torre Avenue Cupertino, California 95014 R�SOLUTION NO. 6604 OF THE PLANNING COMMISSION OF THE CITY OF CUPERTINO APPROVNG A USE PERMIT TO ALLOW THE CONSTRUCTION OF A PERSONAL WIRELESS SERVICE FACILITY, CONSISTING OF A 74-FOOT TALL MONOPINE WITH TWELVE PANEL ANTENNAS AND ASSOCIATED BASE EQUIPMENT AT THE RESULTS WAY OFFICE PARK SECTION I: FINDINGS WHEREAS, the Planning Commission of the City of Cupertino received an application for a Use Permit, as described in Section II. of this Resolution; and WHEREAS, the necessary public notices have been given in accordance with the Procedural Ordinance of the City of Cupertino, and the Planning Commission has held one or more public hearings on this matter; and WHEREAS, the applicant has met the burden of proof required to support said application; and has satisfied the following requirements: 1) The proposed use, at the proposed location, will not be detrimental or injurious to property or improvements in the vicinity, and will not be detrimental to the public health, safety, general welfare, or convenience; 2) The proposed use will be located and conducted in a manner in accord with the Cupertino Comprehensive General Plan, the Wireless Facilities Master Plan, the Wireless Communications Facilities Ordinance and the purpose of this title. 3) That the operation of the facility will comply with federal safety standards for radio frequency radiation emissions. NOW, THEREFORE, BE IT RESOLVED: That after careful consideration of maps, facts, exhiUits, testimony and other evidence submitted in this matter, the application for Use Permit is hereby approval, subject to the conditions which are enumerated in this Resolution beginning on Page 2 thereof; and Resolution No. 6604 U-2010-03 September 14, 2010 Page 2 ' ---------------------------------------------------------------------------------- That the subconclusions upon which the findings and conditions specified in this resolution are based and contained in the public hearing record concerning Application No. U-2010-03 as set forth in the Minutes of the Planning Commission Meeting of September 14, 2010 and are incorporated by reference as though fully set forth herein. SECTION II: PROTECT DESCRIPTION Application No.: U-2010-03 Applicant: Dave Yocke (for AT&T Mobility) Property Owner: ECI Two Results, LLC Location: Results Way SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY DEVELOPMENT DEPT. 1. APPROVED EXHIBITS Approval is based on Exhibits titled: "at&t/CN3242-A/November Drive/Results Way/Cupertino, California 95014" prepared by Jeffrey Rome & Associates, Inc. dated 08/ 31 / 10 and consisting of seven sheets labeled T-1, A-0 through A-3, A-1.1 and C-1, except as may be amended by the conditions contained in this resolution. 2. NOTICE OF FEES, DEDICATIONS, RESERVATIONS OR OTHER EXACTIONS The Conditions of Project Approval set forth herein may include certain fees, dedication requirements, reservation requirements, and other exactions. Pursuant to Government Code Section 66020(d) (1), these Conditions constitute written notice of a statement of the �mount of such� fees, and a description of the dedications, reservations, ana other exactions. You are hereby further notified that the 90-day approval period in wluch you may protest these fees, dedications, reservations, and other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest within this 90-day period coinplying with all of the requirements of Section 66020, you will be legally barred from later challenging such exactions. 3. COLOCATION OF ANTENNAE The treepole shall be structurally designed to accommodate the collocation of additional antennae from other wireless carriers. The co-location agreement shall be at market r�tes wit11 reasonable compensation to the mast owner. 4. ABANDONMENT If after install�tion, the aerial is not used for its permitted purpose for a continuous period of 18 months, said aerial and associated facilities shall be removed. The applicant shall bear the entire cost of demolition. Resolution No. 6604 U-2010-03 September 14, 2010 Page 3 -------------------_--------_____---______--------____________________________ 5. EXPIRATION DATE This use permit shall expire ten (10) years after the effective date of the permit. The applicant may apply for a renewal of the use permit at which time the Planning Commission may review �the state of wireless communication technologies, camouflage techniques and maintenance to determine if the visual impact of the aerial facility can be reduced. 6. TREE POLE APP�ARANCE AND MAINTENANCE The applicant shall use a sufficient number of artificial branches to obscure the appearance of the panel antennae and any associated mounting framework. The top portion of the tree pole shall have branches of varying length to give the tree pole a conical form. Panel antennae mounted away from the mast shall have needle covers to blend with the breen foliage of the artificial branches. The mast shall be wrapped with a faux bark and any antenna mounted close to the mast shall be painted brown to mimic a tree trunk. The foliage shall have a mottled green coloration. The building permit shall be reviewed aY1d approved to the satisfaction of the Community Development Director to ensure the above condition is met. The applicant sh�ll perform regular maintenance of the tree pole to maintain its appearance and obscure the panel antennae from public view. 7. EQUIPMENT �NCT OSURE The base equipinent enclosure shall be constructed of high quality materials and/or be screened 6y appropriate landsca�ing as determined by the Director of Community Development. The final enclosure design, wall treatment/color and screening strategy shall Ue reviewed and approved by the Director of Community Development prior to issuance of building permits. 8. TREE REPLACEMEN The removed trees are to be repl aced with three (3) 24" box Coastal Redwoods in the northwest corner of the property. Final locations shall be reviewed and approved by the Director of Conullunity Development prior to issuance of building permits. Applicant shal l provide a letter fr�m a landscape architect, certifying that the newly planted trees are i�1 good health and the irrigation system is operating properly to maintain tl�e trees. In addition, the final landscaping plan shall confirm that the existing irri�ation systems are operating properly in order to service the existing and new trees in the area. 9. TESTING OF P ADIO FREQUENCY (RF L�EVELS Radio frequency� levels will Ue nlonitored and tested annually for a period of three (3) years from the date of the final occupancy approval. The result of these tests will be made avail�Ule to the Planning Department and the FCC for review. The City Resolution No. 6604 . U-2010-03 September 14, 2010 Page 4 reserves the right to perform code enforcement actions and/or revoke this use permit if the results show RF levels inconsistent with the federal standards. PASSED AND ADOPTED this 14th day of September 2010, at a Regular Meeting of the Planning Commission of the City of Cupertino Uy the following roll call vote: AYES: COMMISSIONEPS: Chair Brophy, Vice Chair Lee, Giefer, Kaneda NOES: COMMISSION�P.S: Miller ABSTAIN: COMMISSIONERS:I�Tone ABSENT: CONINIISSIONLIZS: �ione ATTEST: APPROVED: �s/Aarti Shriv�stava . �s/Paul Bro�hy Aarti Sl1ri��astav� Paul Brophy, Chair Community Development Director Planning Commission G:/plamring/pdreport/��es/2010/U-20f0-03 res.doc U-�o�o-03 / ,.. Vn�.�}V�0'��� .. , ,.. . . . .� .-. . . - , _...._.�;,..� _ __.-�. _,o_� _ . __ .� _..__ , . ... �0��'3�fa�P1� �'C'1'pi=::�S�t7l2 �— 1 �' - 1 0 �}y� � Si�natc�re _ C�sc ��;�r SPECIAL INSPECTIONS 1 CONCREfE 2 BOLiS INSTALLED IN CONCREfE 3 CONCRETE MOMENT—RESISTING SPACE FRAME 4 REINFORCING STEEL AND PRESTRESSING STEEL 5.1 ALL STRUCTURAL WELDING 5.2 WELD TESTING DUCTILE MOMENT—RESISTING STEEL FRAAIE 5.3 WELDING REINFORCING STEEL 6 HIGH—STRENGTH BOLTiNG 7 SfRUCTURAL MASONRY 8 REINFORCED GYPSUM CONCREfE 9 INSULATING CONCRETE fILL 10 SPRAY—APPLIED FIREPROOFING 11 DEEP FOUNDATIONS (PILING, DRILLEO k CAISSONS) 12 SHOTCRETE 13.1 VERIFY SOIL CONDITIONS ARE SUBSTANTIALLY IN CONFORMANCE WITH THE SOIL INVESTIGATION REPORT 13.2 VERIFY THAT FOUNDATION D(CAVATIONS D(TEND TO PROPER DEPTH AND BFARING STRATA 13.3 PROVIDE SOIL COMPACTION TEST RESULTS, DEPTH OF FlLL, RELATIVE DENSITY, BEARING VALUES 13.4 PROVIDE SOIL EXPANSION TEST RESULTS, IXPANSION INDEX, RECOMMENDATIONS FOR FOUNOATIONS, ON— GRADE FLOOR SLAB DESIGN FOR EACH BUILDING SITE 14 SMOKE CONTROL SYSTEM 15 SPECIAL CASES (DESCRIBE) 16 OFF—SRE FABRICATION OF BUILDING COMPONENTS 17 OTHER SPECIAL INSPECTIONS AS REOUIRED B`f DESIGNER DESCRIPTION OF 1YPE OF INSPECTION REMARKS. VICINITY MAP `MAPq'��£ST � etF _ � .;::: __.. �:f�itriirit .c � . ,� i ,, . Rif�ed, Ct � ��„ (�! 4 e.. t Granada_Xve '^� R � ', �, �� ,,, I�mRaAwe ' � �`;. �. a � ' `:,c ° ._ . � � � � � � ' � � a ... � {f�;;cnue Jl�lE ........; �- ,,; � .� � � � -, i i � �i € � €__ a Aka:ae Ave �':. � � � ��� W � _ _ ' 4 , ��061WA „L�. . _ A� �.. .. w;:�w..,,�»�, ,_ , ' �a,_��. � , ... , . 2 E P(}+�est inc . �. . . ; i ,, _ . _. � rn hAap:ratn R�2008NrYTEQ a Tet?¢.Uae CUPERTINO i � � C N 3242-A NOVEMBER DRIVE RESULTS WAY CUPERTINO, CALIFORNIA 95014 CONSULTANT TEAM CLIENTS REPRESENTATNE: ERICSSON INC. 6160 STONERIDGE MALL ROAD SUITE 400 PLEASANTON, CALIFORNIA 94588 CONSiRUCT10N MANA�GER: TIM LENCIONI PHONE: (916) 437-9119 TRILLIUM CONSULTING 5912 BOLSA AVENUE; SUITE 202 HUNTINGTON BEACH, CALIFORNIA 92649 PHON� (714) 799-2000 SITE ACQUISRION Ac ZONING: TOM JOHNSON PHONE: (714) 206-2879 RF ENGINEfft: HAKAN BATIKHAN (AT&T) PHONE: (925) 300-6919 ARCHITECT: JEFFREY ROME AND ASSOCIA7ES 3 SAN JOAQUIN PLAZA SUf1E: 155 NEWPORT BEACH, CALIFORNIA 92660 PHONE: (702) 324-4338 FAX: (949) 760-3931 CONTACT: ROBIN NELSON LAND SURVEYOR: CAL VADA SURVEYING, INC. 411 JENKINS CIRCLE, SUITE 205 CORONA, CALIFORNIA 92880 PHONE: (951) 280-9960 Fp(: (951) 280-9746 COP(TACT: RAMON GONZALEZ DEV�LOPMENT SUMMARY APPLICANT: AT&T MOBILIIY 442Q ROSEWOOD DRIVE PLEASANTON, CALIFORNIA 94588 OWNER: ECI 1W0 RESULTS LLC. 1301 SHOREWAY ROAD; SUITE 258 BELMONT, CALIFORNIA 94002 CONTACT: ANDREW BROWN PHONE: (650) 292-4100 OTHER ON—SITE TELECOM FACILITIES: NONE PROJECT ADDRESS: ASSESSORS PARCEL NUMBER: LATITUDE: LONGITUDE: LAT/LONG TYPE: EXISTING ZONING: PROPOSED PROJECI AREA: PROPOSED TYPE OF CONSTRUCTION: PROPOSED OCCUPANCY: EXISTING TYPE Of CONSTRUCTION: EXISTING OCCUPANCY: JURISDICTION: COUNIY: RESULTS WAY CUPERTINO, CALIFORNIA 95014 357-20-046 3T 19' 10.18' N 127 03' 09.82" W NAD-83 P (ML) 935 SQ. FT. lYPE V-8 U NOT APPLICABLE NOT ACCPUCABLE CITY OF CUPERTINO SANTA CIARA PRQJ ECT DESCRI PTI ON ATdcT M081LITY PROPCSES TO CONSTRUCT, OPERATE AND MAINTAIN AN UNMANNED WIRELESS COMMUNICATIONS FACILITY. THIS FACILITY WILL CONSIST OF THE FOLLOWING: • INSTALL A PROPOSED MONOPINE WITH (12) PROPOSED AT&T ANTENNAS WITHIN THE PROPOSED EQUIF'MENT ENCLOSURE. • INSTALL (24) RUNS OF 7/8"0 COAXIAL CABLE AND (12) TMA'S. • INSTALL AT&T OUTDOOR E�UIPMENT CABINEfS MOUNTED ON A CONCRETE PAD WITHIN A CMU WALL EN�LOSURE. • UNDERGROUND UTILITY RUNS FOR ELECTRICAL AND TELEPHONE. LE�AL DESCRI PTION BEING ALL OF PARCEI 3, AS SHOWN UPON THAT CERTAIN PARCEL MAP WHICH MAP WAS FILED FOR RECORD IN THE OFFICE OF THE RECORDER OF THE COUNTY OF SANTA CLARA, STATE OF CALIFORNIA ON APRIL 12, 1979 IN BOOK 439 OF MAPS AT PAGES 12 AND 13 AND BEING A PORTION OF THE LANDS DESCRIBED IN THAT CERTAIN DOCUMENT RECORDED OCT08ER 14, 1975 IN BOOK 8662 AT PAGE 46 IN THE OFFICE OF THE RECORDER OF SANTA CLARA COUNN AND BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT THE SOUTHWESTERLY CORNER OF SA10 PARCEL; THENCE ALONG THE WESTERLY LINE OF SAID PARCEL NORTH 00' 01' 00" WEST 241.44 FEET TO THE SOUTHWESTERLY CORNER OF THE LANDS DESCRIBEO IN SAID BOOK 8662 AT PAGE 46; THENCE ALONG THE WESTERIY LINE OF SAID LANDS NORTH 00' 00' 33" WEST 318.23 FEET; THENCE SOUTH 89' S6' 46� EAST 274.02 FEET TO THE EASTERLY LINE OF SAID IANDS; THENCE ALONG SAID LINE SOUTH 19' O6' 48" EAST 335.47 FEET TO THE NORTHEASTERLY CORNER OF SAID PARCEL; THENCE ALONG THE EASTERLY LINE OF SAID PARCEL SOUTH 19' O6' 48" EAST 293.23 FEET TO THE SOUTHEA,STERLY CORNER OF SAID PARCEL; THENCE ALONG THE SOUTHERLY LINE OF SAID PARCEL NORTH 82' 24' S1" WEST 261.05 FEET; THENCE CONTINUING ALONG SAID LINE NORTH 89' S7' 24" WEST 220.99 FEET TO THE POINT OF BEGINNING. �._..--- _._a..___...._ _.-CXG- 20l0 �0�� TIZ-�oio--�31 , . . u � 03. . � ; :� . � . . � � � . . � � • ■. �� F � � �.... , ... �.�.���_.: .. � ' i � . _ j y Y �' ' •... � � .. _..+�✓ � . ...� . � : � �_ ..� ; �- . - � 1 � �.._._.�..__.._.,,.. >, .. .. .. ......_._...... _._._ a_. _._..._.. .,... �.....�. .. _......�.....__,,..�_._.,..,.,,,� SHEET INDEX T-1 TITLE SHEET A-0 SITE PIAN A-1 ENLARGED SITE PLAN A-1.1 TREE REMOVAL PLAN A-2 NORTH & SOUTH ELEVATIONS A-3 EAST ELEVATION C-1 SITE SURVEY (FOR REFERENCE ONLY) APPLICABLE CODES ALL WORK SHALI COMPLY WITH THE FOLLOWING APPLICABLE CODES: CALIFORNIA BUILDING COOE, 2007 EDITION, B0.SED ON THE 2006 INTERNATIONAL BUILDING CODE CALIFORNIA FIRE CODE, 2007 EDITION, BASED ON THE 2006 INTERNATIONAL FlRE CODE, CALIFORNIA MECHANICAL CODE, 2007 EDITION, BASED ON THE 2006 UNIFORM MECHANICAL CODE CALIFORNIA PLUMBING CODE, 2007 EDITION, BASED ON THE 2006 UNIFORM PLUMBING CODE CALIFORNIA ELECTRICAL CODE, 2007 EDITION, BASEO ON THE 2005 NATIONAL ELECTRICAL CODE CALIFORNIA ENERGY CODE, 2007 EDITION. IN THE EVENT OF CONFLICT, THE MOST RESTRICTIVE CODE SHALL PREVAIL ACCESSIBILITY DISCLAIMER THIS PROJECT IS AN UNOCCUPIEO WIRELESS TELECOMMUNICATIONS FACILITY IS EXEMPT FROM DISABLED ACCESS REQUIREMENTS. SCALE THE DRAWING SCALES SHOWN IN THIS SET REPRESENT THE CORRECT SCALE ONLY WHEN THESE DRAWINGS ARE PRINTED IN A 24"X36" FORMAT. IF THIS DRAWING SET IS NOT 24"X36", THIS SET IS NOT TO SCALE. �J RA J�ffrsp Rom� �C Asaoctatea� Inc. Archit�cturo R T�I�communicatlons 3 San Joaquln Plaza, Suita 155 N�wporl Bwch, Califomia 92660 Phone: (949) 760-3929 Fox: (949) 760-3931 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO ATBcT MOBILITY IS STRICTLY PROHIBITED. STAMP c �c�D AR('y� J 'l Rq� �r � * � C-020876 ^ yt t, 0 s F EB. 2a' �Q qr F Q" CA��F� PREPARED FOR µ. at&t 4420 Rosewood Drive Pleasanton, Caiifornia 94588 APPROVALS R.F. ENGINEER DATE SITE ACQ. & ZONING DATE ERICSSON CM DATE AT&T CM DATE OWNER APPROVAL DATE PROJECT NAME NOVEMBEI� DRIVE PROJECT NUMBER CN3242—A RESUITS WAY CUPERTINO, CALIFORNIA 95014 SANTA CLARA COUNTY DRAWING DATES 02/10/09 PRELIMINARY ZD REVIEW (P1) O6/08/09 DESIGN CHANGE (P2) 07/02/09 FINAL ZD'S (P3) 01/26/10 SITE RELOCATION (P4) 05/10/10 1007: ZD'S (P5) 05/21/10 CLIENT COMMENTS (P6) 06/10/10 CLIENT COMMENTS (P7) 08/16/10 PIANNING COMMENTS (P8) 08/23/10 CLIENT COMMENTS (P9) 08/31/10 REVISED ANTENNA COUNT (P1 RFDS REVISION LEVEL 1.6 SHEET TITIE TITLE SHEET � M O 0 m _ � � z � T-1 U W � 0 a a � � - SITE PLAN KEYNOTES O 1 PROPOSED ATdcT ANTENNAS MOUNTED ON A PROPOSED MONOPINE WITHIN A PROPOSED ATdcT EQUIPMENT ENCLOSURE; SEE SHEEf A-1. 2 PROPOSED AT&T 22'-0� X 42'-6" LEASE AREA WITH OUTDOOR EQUIPMENT WITHIN A 6'-0� HIGH CMU RETAINING WALL ENCLOSURE TO MATCH EXISTING; SEE SHEEf A-1. 3 EXISTING UTILITY POLE MOUNTED TRANSFORMER AND PROPOSED AT&T POWER SOURCE. 4 EXISTING UTILITY POLE dc PROPOSED ATdcT TELCO POC. 5 PROPOSED 5'-0" WIDE AT&T UNDERGROUND POWER dc TELCO CONDUIT ROUTE. DISTANCE 318'-0"t. TELCO CONDUIT SIZE TO BE 4" DIA SCH. 40 PVC. POWER CONDUIT SIZE TO BE SPECIFIEO BY SERVING UTILITY COMPANY; SEE DETAIL 2/A-1. 6 PROPOSED 12'-0" WIDE AT&T ACCESS ROUTE TO SITE. TO BE CHANGED AFfER DEVELOPMENT OF SITE. 7 FUTURE DEVELOPMENT ASPHALT PAVED PARKING. (UNDER SEPARATE DEVELOPMENT). 8 FUTURE DEVELOPMENT BUILDINGS. (UNDER SEPARATE PERMIT). 9 EXISTING BUILDINGS ON PROPERTY. 10 EXISTING PROPERTY LINE. 11 FUTURE DEVELOPMENT ACCESS DRNEWAY AND FUTURE 12'-0" WIDE ACCESS ROUTE. _...��.. _ __....., . . ... ............._,.�...1.. .....,_.-....,......�..._.. � �,.. _" �. r._ . �,_ ..,.. x _ � ___ . - -... -- _....._. _ ._._ _..M. �. ___ _ -,-_______._. . . � � �G - 2a10 �a 4; ?7e-Zot d � t � j L`Z��Q��� , „' , r � : � . � � l�'.Za.� "' Q..�?. . � � �x � Z�� � � Q (,�'' ' r ;. ,ry �^ s P P• �'Q � 1.0 { 0� 3 � S ' � �,. � E' . . ..,� ,. . ,. + . �,..^��:fl.;�atisa::reu�,�.�_.. v _..__. . . � .. . �, • �. .__�~_I��f� � � [^' '���±s� p `�..i.. 3.����y •����0 � . ; "�Rf.1 0 �� � � �r.�rw� � . , A : F / ♦ � � �' � �1D.i Y ;.. � ,. - .. ...... �.._.� _.... ......�..___..__. ..-.__.. * f . ... � � � � ! ���;��$�Ba''� : _ .. ` � � -. Y> � L'i0�� �i� =;C�' ,. : . �. .. . �, �/t. _ _ ' ,.: � 4.... _ � '� r t�. ��� �' , ' � _, � � .. .. . �.�"...,.'" !.k` �� �` ' , i / f ..�. 1 �.�,_.....,,,�,...,...�. ..-,-.-�'=.�;;�: - ,...-. ,,,.�� � ..P,...e. ' i �., � ..., � '� ' � . �/ ,r ' �- � .. / /l y �r 44� rl"��_ . , ; � �--` ' ^_�� " r � �� -- \ ,,, ,^.- , _ „ � _ � . _ / ' ��-""� = � I _ -� � / f.� q !., � > � �;�. �, � J i-' i BIO wkC� -''` �- ' 4 � �� , ; ,. � � r''� � :,....--`'"'' i � - � i � (�� , -,"'�� ' � ' . '; ° ��.t � . � �'- ,r ':� - / / /o f �� ' \ i4�' { ��, ...1 �/' � i 4. ./�i , .. -'�4 "� � / / ./'"���... ��� ,r..+ r / \ \` � 6 ,,,�r � , .- ' • • y � � .. . ..� j• „� . - �,-- �, - ,.= � ! �-� ! �� / �. ^�./ �`�..., � r �,. �,� ; -: .--'' „ �' � �.�- �- -�- � : -t" i r � 4 -• r �i' -- �RO � P " �. � � � f � � � �� f `'\ �� i ° \ � '' '' � - � � � � ' � � P . 1 � i / ' �'6.� .. � % ��� .. � �5 , r . ��� � - .,� ..� � �, z�. ��.,..-�g �: r - _ _ ,.. _.- ; / !" T � �� � N , ._.:-„ .. ?� , „r.:_. � � ' 3 �. f r .�a ...�, ; �, ,- _� :=-�%�~ ,✓���,,- �wF�� , , i�,� ,� , . `�� : � ,- r �. � � ., , i r' � � �-.r - �. � os � E � � ,, . i .. \ -i_' r,..%' . � .-� y / ( ) ''/". i . `._ _. �_. _ P � , � / f . __ . ,� � - � �C , � _ , >--- - ,,.-- i �-� - � �i . :; � . fJ / t�'�/ ' ,,,.�'� i %' .','/ 4, .. . i I ^�. // � �F��� / �, ` / \ J/rl J~ -... ./ w/ / � . 1 ' �.f . �� �.--' , ,� . � �' , � � � �� ; ``. �-- - � . ' ¢ � � � � � • � ` f � � , � � / r' �i'.%' '�. ,- �- �- �;i/ • - ; . �, - , .', a i � _. i �,, ,,,,, . -� ;,,. � ,-- . � � � � � � i . -- ' '� . ' \ � , . ` , ;- ����,,,. �, � �� , ,�/ „ E� __.. �� � .-- � � \ � . 3 ' '� v �� / '--�,�Y �/j � � . � �j - ; _ - � , . - �, � ./' 6 �.. % � ,i "i� �'` , �,�,_ � � � i � . � � F � �'" - ���G� / ; . i � �-.-� � . .; � / ;� �' .- ', � � � � � � ( ' � _ y, 'CP �33�.CT4� , .. �` 1 �/ .. _�„i_': -'' �.-r'•",.�' /" ,,-�'i / '- � /�� f _ - 8 ' ; � � , ^ ,,.- " , _ _ �, � '`i X� � / _ � "'� �"�'�`� ��IOSWALE -..�-" .�-'.`. " w `...' � �,.. � � � .. t � �,, jl i / /,� . �, . � / - , �,�,.. • - .- . -� � � : ,� � _-- � ,!r. �-" i .i �.�- ..af / - � .. "�" ,..� j�- � / (TYF) � i � � __ cT' - 33 .5� � �'t'� --- _ _� � . .. _ - _ ,.; ` / ✓ ' r , � ✓,., - . .. � - . � � ,�-. . ._. _ r .= �,,.!' -' ' / ^ „ � . �„�-- / � /.. . M /' � / � / \ f� � / � �,'''�^. _. �/ , `` � . 1,.� , , � �� � ,.- . � , l ,.i�, i . . .; . ., , / .. , : - . ', ', ` � ' �._ � . ., �- l , : � ,-, ,, � ,,�� �� � ; ------,-, r, � ,-- S i �� $fOSWO�LE �� i I '�� LENGTH A3 � 20' KATHREIN 742-264 70 10 7 B A4 20' KATHREIN 742-264 70 10 7 B B1 260' KATHREIN 742-264 70 10 7 B B2 NORTH 260' KATHREIN 742-264 70 10 7 8 83 WEST 260' KATHREIN 742-264 70 10 7 8 84 260' KATHREIN 742-264 70 10 7 8 C1 140' KATHREIN 742-264 70 10 7 8 C2 SOUTH 140' KATHREIN 742-264 70 10 7 8 C3 WEST 140' KATHREIN 742-264 70 10 7 8 C4 140' KATHREIN 742-264 70 10 7 8 ANTENNA COAXIAL CABLE SCHEDULE 2 1. CONTRACTOR TO PROVIDE ALL LABOR TO INSTALL 30 RUNS OF COAX, 12 TMA'S AND 12 ANTENNAS. 2. ERICSSON TO PROVIDE ALL COAX, CONNECTORS, ANCILLARY EQUIPMENT (INCLUDING WEATHER STRIPPING, GROUND KITS, ETC.). 3. CONTRACTOR TO COLOR CODE ALL COAX. COLORED BANDS OF TAPE ON COAX IDENTIFY SECTOR, FREQUENCY, TECHNOLOGY, ANO TRANSMIT GROUP AS FOLLOWS: } _; � - ; --.. . ;�� � f ,! % � '�.� I , ��,% i r '� ' ' _ -, � �� - � �!�:-; % .% � '� � "� � � � i � f 35 �,- �P� 5 yVP f � - � - , I ,y� � ,,- � ,�„' X �.- �-' i ---" � � ./ � .- � % .i .- � � �_._.._ , , - ,: �� S'1 L i: i - - . ; r �� .. �, (� -�,,, i � /y � . �^�, � w / � � .....-- \ t n � y. . - . �/ � / � / ; � _ _� �~ � \.. \ " � � '��i�=� � � -+h*' '` l .. /' r � i . , � � " 6 e.. ��. . � �, r ��, � � .Q%Y � i � '`� � r -- _ _ _ _ . � ` j . , \- , . .- ., ���. Y � � . ,,.,.-,����""% � . j .:,� . /.� � . , `=^ ' l�i �•+ _ ` � 1 �', ., `��.. �...�� i � i� � _..._. �.�._:,�.. ^� .� . !: � , � L ` - 1 - . , - , �., , ,-�°' , . , ,i r r „ ,�-'- ; ,a ,. � i . -� I � �,��'�� � - i r r _ I� h�-�-'?`� � I � �„ �, � .- ,.r-� � -. � � i - -' 9 � I / t' . / / ; ; � 1 ' � � , _� __ E ,-C '�u' �---'" v ,, y ;.. � �� _._ -- __ __ _ - i�3 -., L� �,._ � '� � . � � � � ` !S"- i _ .; '/�, i I ! � --��' ; 'S . ' i , ��� .� � � � » �� -r _ r , . , / -'-' �;,';^ r : ,`. F ` , i � � . _ � . - /: '. -- . I : • O , ( : - / _ �, J . _ , f �.. �'� � -- --'� � c.> �: k; r I p P •' �', .;. ��.�� _ > - '; , � '. i i ; x i � � _ , f � .� , . � � i .. , � . �/ ; �. , i . _ , ., .-� 329.� 3:5'� . `, •.�.. -� ; 8 � , _.., y _ . ��'� ,,,# - 1 ; - • � ' � � �; �,.,� �-� , , .` ,, ' . �' � , ., �i ,� , O /� � ,� . � \ E� _ T � r.X / �.�., '. . ,. . � � .-,� .... . , \� �I� �v 1� ., ��.. � �/.�// �`�A� ✓`..':;.� �36 \�. ���!r:s: jY \ � I I / , , , ! :i4t ��.. . t , ! � '��, �� G ', _ � / \,,�/ Q r. e .� ; ,�� -�35'� _. � : � � " 1 , ,-,^ �"� '� ' � ( � � . --' . : 335:9 � d36' � - - - i - . 1 ! ' � ' _. . - � , � _... , � , � , � � 10 { , - � .� -�%- , � , � r- 1 I - �. ; �� � / i �i 1 �^ �.,.: . � � � � � , , , . , r ,. G- � � "' `° ' � - "� . � ;, ` I i ' I � ,i -� •;�, ,,_,- , _- � - ! �, ,, ,, --.. = . ,;; � , _ - - � �a� _.. - - - _ _. _ � - -- -- U/ /,g, -'" 1 f . ...�_� - -- - - - � �-r , � -. / � - -- - - - ,-�. , ,,,' `, ,, ; ` , } -- � `,, � ' ' � � _ _ - -- -- - - - , . � , , , , �� �, - � // � �, 4 , j ,., � ,.=�' -^.. ' - � /, . < . . , ', , �_ . � , - � �-. � � ' ., . , f� ', , ` �U1L !f0 �J - _ , , , , � � _ .. , - , . ; �,�r � , , , , � � ; � , - �_ _ � � � /; � - `i ,. . : ,�-�-;� �, r ., �, �, I -�.,',, � h, ���€'� : 8 ' � , - _ f � , , , � �� � _ � �%,; . ;, r: .w. � � �. ,�..: � .� �t ' ', �. ..�.) 1 �� l. . . � � __...__.. _ .__ __ . 1 1 ' � �"'r. 1 .��.\ "�. � . .• '%'`� � � I / ��� TC � _ E , r: , , .' , O , . .__, '�.. . � I _. � I ,_ . . . . _ tr � I I � � �� x� �"� � = i � �; 4 �: y . �. .. I � �« • r `l � � i �� .. - ..i� ..._ .._. � } o'- ` 1 s v .c � �� � , 1� ,�' ,, _`:-�' �' „�• � I ' i � � � �� . d i ,._. ._ i . .. ' ..... �, + :.,� �, �, i _ - � , `��, '�, ' �' ,� `�, �. ���y � I I ,:� � r , `L' , _. �' } I J � ' " � � I ��ff�� AP • 357 20 046 - - Pi��5.t � j; ! `��� . 1 .- _�_�--- , BIOSWALE (T1P)� ' � 2 � --- ---3 � x ; ^ ; ; E � � � �-} R ,,z a%. : � �• 1 � ; : : � � � �. �..�. 14 L i,- I� II II II II �� �� II II --- o\t � IYPERIAL AVENUE � �r - �� \� SITE PLAN � N. - - ,» � � APN. 357-20-041 � I �- �; � ZONING: P(ML) �`"i' , �,:: I ��; ZONING: P(ML) i's; � � 1 - � i ; 8 . � �� � 9 BUILDING 5 I I � a � I , i 1 �� NE�N BUILDING C '"�' 2 �� �;� OEX FFE 343.8 i I �� : '� � ..�- - . _._ ..-i i FFE 336 ; .._� � � �,�° < : ' � i�: 3 _ . _ ...._.,� J � . : � � t �.� � I ��j t PAD 335 � i. � �_ � � � � �' i ; 4 � � � !�' ., � EXISTING LOT LINE 1 I � I � �I' � � I �' �� � i ,� 507 -2 ' � � i � , ;. 1 - 1 _ - I I-- . � ' 336 .--•--�-�� J ~;4''.�i -- �f - :- t _ .......... .... -.. .._ ...____ .... I �_ � 't `` _ . , ,� -._ -- - -- _ i , ; I 1.- � � __ ----�'� �� : _ _ � ' , ,� . _ L - i s ; ; . -, - _ , ,. � � r . � : , h �.�:: � _�..� . , r , �..9 r _ 1 : - / .� �; � ��a,,.,r,�_ �..,.,,._.,,�.., �.., ._� � ...� . , j --- V , � �' $ , , � „, ;- ��. ,. „ , ; � � � I � , i � E � " - / .. I '�-� ; �, ; .; � J ' I ' _ - � �3� 0 ._.� � �; � , � � � � , E . `_ 't � ; , � -`F- m� - , ` � - (- � + - - - - - - - - - - - �e:,,�y � � �.,. _ � ' '\,._,,�' ".. � - �- - �- ' - t � - �'�'� '_`�' L - - -pRpR(1SE��,pT�ID{E �°'��x �- '� PROPOSED/LOT IJNE-�I �EXISTING �' y i 1 ' ' � i j _ : �, � ; ' ; � � I ' i � i 1 �,, �- ` . .. i . ! ' �. ( i � , , �. � I , . i � . . I I i i f �� i P, il, �: i I � � i :l '• � . . . . . I i i � l'. � r -- - - - - v ��,. L-`- _. � ' - , , �� � � � � - ._ ... �� . ...._ �. _ _ _..... / - --- .� -._ ____ _< ----�-.,-_.._,_ _ _.__ ---..�_..._ �. r ; _.... _.__._. ., , _._� _ . --- �..� --"�'•. -------- _�.._. _ \ r -_ _-._.._ _ �..� _�._ / � „ ,-- . _ _._._.___ _ � SECTOR "A" TX 1/RX 1 TX 3 TX 2/RX 2 TX 4 TX 5 TX 6 GSM 1900 2 BROWN 2BRWN/1RED 2 ORANGE 20RG/1RED 28RWN/2RED 20RG/2RED TX 1/RX 1 TX 3 TX 2/RX 2 TX 4 TX 5 TX 6 GSM 850 3 BROWN 38RWN/1RED 3 ORANGE 30RG/1RED 38RWN/2RED 30RG/2RED TX 1/RX 1 TX 2/RX 2 UMTS 1900 q BROWN 4 ORANGE TX 1/RX 1 TX 2/RX 2 UMTS 850 5 BROWN 5 ORANGE SECTOR "B" TX 1/RX 1 TX 3 TX 2/RX 2 TX 4 TX 5 TX 6 GSM 1900 2 YELLOW 2YEL/1RED 2 BLUE 2BLUE/1RED 2YEL/2RED 28LUE/2RED TX 1/RX 1 TX 3 TX 2/RX 2 TX 4 TX 5 TX 6 GSM 850 3 YELLOW 3YEL/1RED 3 BLUE 36LUE/1RED 3YEL/2RED 3BLUE/2RED TX 1/RX 1 TX 2/RX 2 UMTS 1900 4 YELLOW 4 BLUE TX 1/RX 1 TX 2/RX 2 UMTS 850 5 YELLOW 5 BLUE SECTOR "C" TX 1/RX 1 TX 3 TX 2/RX 2 TX 4 TX 5 TX 6 GSM 1900 2 y�OLET 2VI0/1 RED 2 WHITE 2WHT/1 RED 2VI0/2RED 2WNT/2RED TX 1/RX 1 TX 3 TX 2/RX 2 TX 4 TX 5 TX 6 GSM 850 3 VIOLET 3VI0/1 RED 3 WHITE 3WHT/1 RED 3VI0/2RED 3WHT/2RED TX 1/RX 1 TX 2/RX 2 UMTS 1900 4 y�OLEf 4 WHITE TX 1/RX 1 TX 2/RX 2 UMTS 850 5 VIOLEf 5 WHITE 4. WHEN ANTENNA LINES ARE DIPLEXED, THE COLOR CODE OF THE HIGHEST FREQUENCY PREVAILS (I.E. UMTS DIPLEXED WITH TDMA SHOULD HAVE COLOR 4 BANDS). 5. ALL ANTENNAS ANO ANTENNA CABLE SHALL BE FURNISHED BY ERICSSON INC. AND BUILDING 4 g INSTALLED BY ANTENNA INSTALLATION CONTRACTOR. 6. PRIOR TO PLACEMENT OF ANTENNA POLE MOUNTS, THE CONTRACTOR SHALL VERIFY THAT THE AZIMUTH AND DIMENSIONS SHOWN ON THE PLANS MATCH ACTUAL FIELD CONDITIONS. A L L O W A B L E T O L E R A N C E: H O R I Z O N T A L A L I G N M E N T = t 5'; V E R T I C A L A L I G N M E N T = t 1'. 7. ANTENNA INSTALLATION CONTRACTOR SHALL PROVIDE ALL CONDUIT, CABLE TRAY, � GROUNDS, EfC. FOR COMPIETE INSTALlATION OF ANTENNAS AND CABLES SHOWN ANO -- -- - - ; INTENDED AS RE�UIRED FOR A COMPLETE OPERATING SYSTEM IN ACCORDANCE WITH �, / ERICSSON INC. STANDARDS. i i i i i i i i i i i li i '' ''.�� i, ; �!,( `� ; 8. IN NO CASE SHALL THERE BE ANY MORE THAN TWO (2) 90' TURNS (OR EQUIVALENT) IN �,1-.�=-� -� , J �,� �� i, ANY CONTINUOUS LENGTH OF CONOUIT BEfWEEN PULL BOXES OR SIMILAR FEATURES. � f `� 9. ANTENNA CONDUIT SHALL ONLY INCLUDE FACTORY-MADE LARGE RADIUS SWEEPS AT ALL CHANGES IN DIRECTION. SWEEP RADIUS SHALL BE 18" MINIMUM A80VE GROUND aT uNE AND 36" MINIMUM BELOW GROUND. i � i • I i . I N IT SHA E 3"0 MINIM M N R R N N IT HA H 10. CO DU LL B U. ALL U DE G OU D CO DU S LL 8E SC EDULE _. -- -- �- �._., -. -�"__ 40 PVC. ALL EXPOSED CONDUIT A80VE GRADE LEVEL SHALL BE IMC OR RIGID �-----�""'�-' GALVANIZED. ALL EXPOSED CONDUIT PROTECTED IN A BUIIDING OR ON A ROOF SHALL lwlr.air� �+r ; ; , '-- - - �- - _-'�'�`-'"- -- -- - - _ . � -- --� - �-+-�.RZ�- _�- - --��-,-�- -- -- BE EMT OR W STABILIZED PAINTED SCHEDU�E 80 PVC. '.r: • f ; ; '" ; '"' ; _ /,,_ -, � , � f ' ` °' � ' � ; ! 'F'' '-' ( i ,s�°"l - f ' � � '"-" "�I �� J J ; 1 1. IN HIGH TRAFFIC AREAS OR WHERE SUSCEPTIBLE TO DAMAGE CONTRACTOR SHALL I.. _ ` ' I i� _� J f I ______ _.� -- -.. 3 � . <�� : i � _....._�; � � ; �' � _ '� � PROVIDE FORMED GRIP STRUT COVER OVER COAXIAL CABLE ROUTES. WHERE CABLE IS � ` ' ' � ' - '' ' ''° RUN ON THE WALL ATfACH UNISTRUT TO WALL AND COVER WITH 14 GA GALVANIZED � _, � I W � _ t � N � o � O � - - - Q7 5 3 4 i I 6 NOTES: 1. FUTURE DEVELOPMENT SHOWN TO CLARIFY ACCESS ROUTE AND UTILITY ROUTING FOR PROPOSED AT&T SITE. ALL DEVELOPMENTS IN THIS DRAWING OTHER THAN REFFERING T AT&T IS UNDER SEPARATE PERMIT. 2. FINISH ELEVATION GRADES BASED OFF OF FUTURE SITE DEVELOPMENTS BY DEVELOPER. SCALE: , --60� FORMED SHEET MEfAL COVER �R MATERIAL AS DIRECTED BY ERICSSON INC. CONSTRUCTION MANAGER. 12. VERIFY ROUTE AND LENGTH OF CABLE PRIOR TO CUTfING. ADJUST INDICATED ROUTE AS RE�UIRED TO CLEAR (E) EQUIPMENT AT FACILITIES. 13.MAXIMUM LENGTH OF 7/8" COAX CABLE SHALL BE 140'-0". MAXIMUM LENGTH OF 1-1/4" COAX CABLE SHALL BE 190'-0". MAXIMUM LENGTH OF 1-5/S" COAX CABLE SHALL BE 235'-0". 0 14. VERIFY MODEL NUMBERS OF ANTENNAS WITH ERICSSON INC. SERVICES. N 15.THE CONTRACTOR SHALL PROVIDE TESTING OF ANTENNAS AND SHALL PROVIDE DOCUMENTATION TO THE ERICSSON INC. PROJECT MANAGER. 16. GENERAL CONTRACTOR TO VERIFY ALL TORQUE TOLERANCES PER THE MANUFACTURERS SPECIFICATIONS AND RECOMMENDATIONS. o � o . 3 GENERAL ANTENNA & CABLE NOTES � �.J RA J�ffnq Rom� � Asaociata, Inc. Archit�ctun � T�I�communicatione 3 San Joaquin Plazo, Suifa 155 Nswporl 8�ach, Califomio 92660 Phons: 949 760-3929 Fax: 949 760-3931 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO ATBcT MOBILITY IS STRICTLY PROHIBITED. STAMP C,� AR J '1 Rq� �i � * C-o20876 * t, p �. s F fB. 2�'���P Ar F Q" CA�� PREPARED FOR at&t 4420 Rosewood Drive Pleasanton, California 94588 APPROVALS I R.F. ENGINEER DATE SITE ACQ. & ZONING DATE ERICSSON CM DATE AT&T CM DATE OWNER APPROVAL DATE PROJECT NAME NOVEMBER DRIVE PROJECT NUMBER CN3242-A RESULTS WAY CUPERTINO, CALIFORNIA 95014 SANTA CLARA COUNTY DRAWING DATES 02/10/09 PRELIMINARY ZD REVIEW (P1) O6/08/09 DESIGN CHANGE (P2) 07 02 09 FINAL ZD'S P3 � � � ) 01/26/10 SITE RELOCATION (P4) 05/10/10 100X ZD�S (P5) OS/21/10 CLIENT COMMENTS (P6) 06/10/10 CLIENT COMMENTS (P7) OS/16/10 PLANNING COMMENTS (P8) 08/23/10 CLIENT COMMENTS (P9) 08/31/10 REVISED ANTENNA COUNT (P10) RFDS REVISION LEVEL 1.6 SHEET TITLE SITE PLAN A-0 � 0 0 � � � z U W � 0 a a � ENLARGED SITE PLAN KEYNOTES O 1 PROPOSED AT&T ANTENNAS MOUNTED ON A PROPOSED MONOPINE. ANTENNAS TO HAVE NEEDLE COVERS OVER PROPOSED ANTENNAS; SEE DETAIL 3/A-1. 2 PROPOSED (3)_ ATdcT OUTDOOR EQUIPMENT CABINETS MOUNTE� ON A CONCRETE PAD. 3 FUTURE (4) AT&T EQUIPMENT CA8INETS. 4 PROPOSED AT&T GPS MOUNTED TO EQUIPMENT CABINET. PROPOSED AT&T HORIZONTAL COAXIAL CABLE RUN MOUNTED TO WALL. PROPOSED METER�MAIN, EMERSON LOAD CENTER, AND WEATHERPROOF G CI MOUNTED ONTO CMU WALL WITH UNISTRUT. PROPOSED TELCO FIBER MUX CABINEf AND ALARM CABINETS MOUNTED TO CMU WALL WITH UNISTRUT. PROPOSED TECH LIGHT MOUNTED ON PROPOSED H—FRAME UTILITY RACK. PROPOSED WATERPROOF SWITCH FOR TECH LIGHT TO BE MOUNTED TO CMU WALL. PROPOSED 6'-0" HIGH CMU RETAINING WALL, WITH CLADDING TO MATCH FUTURE BUILDINGS IN COLOR AND STYLE. PROPOSED 4'-0" WIDE SINGLE METAL TUBE ACCESS GATE. PROPOSED 5'-0" WIDE AT&T UNDERGROUND POWER & TELCO CONDUIT ROUTE. DISTANCE 318'-0't. TELCO CONDUIT SIZE TO BE 4" DIA. SCH. 40 PVC. POWER CONDUIT SIZE TO BE SPECIFIED BY SERVING UTILIIY COMPANY; SEE DEfAIL 2/A-1 FOR TYP. TRENCH DETAIL. EXISTING CONCREfE CURB. EXISTING ASPHALT PAVEO PARKING. EXISTING TOE OF SLOPE. EXISTING TOP OF SLOPE. EXISTING TREES AND SHRUBS TO BE REMOVED. EXISTING TREES AND BUSHES, PROTECT IN PLACE. EXISTING BLOCK WALL. EXISTING PROPERTY LINE. PROPOSED AT&T ACCESS STAIR AND WALKWAY. PROPOSED 4'-0� HIGH REfAINING WALL. SE�TOR "B 26 NOTES: 1. FUTURE DEVELOPMENT SHOWN TO CIARIFY ACCESS ROUTE AND UTILITY ROUTING FOR PROPOSED AT&T SITE. ALL , DEVELOPMENTS IN THIS DRAWING OTHER THAN REFFERING TO I ; AT&T IS UNDER SEPARATE PERMIT. 2. FINISH ELEVATION GRADES BASED OFF OF FUTURE SITE DEVELOPMENTS BY DEVELOPER. �-. _,,. ...._.,.__.._..__.. � r ,_....�.,._, ti,. _....�. � f �� 04'� � �o'�Dt O "3� � . �. V�'�l O. " 03. , F , i . _ , ,_ ; _. . ; I ` . . - . —14-�t 0 : � " . , . , . _ � . _ �, . ..._....._- .._ ,i � ,.. 4 � , . a ,� !.__.�_' ..._..._,..... .n I 4 ,. . d..� ,�..... .1. . � � a � � � . � .... ... I . � ` X � . ��: . I � ..�...., .e__._.....,R,F,,,... � �..�_.. R. �_.,..,...x. J...�._.�, ENLARGED SITE PLAN � �� � ` 17 �, i' � � i , � � � 22 =0 � , ` � ATdcT LEASE AREA � 21 � , 2.Q�t F.G, 332.2 t ; Q F.�S. � � 18 20 � ��� I Crl� 2 � 332.67 t , is 4 ,_4. F.S. � 332.83f � � � F.S. � ----� --- , (i � ��� � � � ' I I I I � ';; l� — � � ---� �` �� � I � � I I / � I I I I � i `� — — , �� ' � ' ,,, � 8 % � � , � � � I --- � ;' �, � � I I � , 10 � I I 1 � � 33 .25f �--� 'F.S. � � � � � I I �� � � � � k j j , �, � \�� i i , , 14 ; � � -- � � ;, � I �-� ,, , � 7 � \� � ;�� � �� � '�; 16 I � / � "�� � ,�—s I / \ � ��;� I / � ' S I �32.83 i 332.67 I F.S. ' F.S. � , / 331.67t� _ F.G. s'—o• � �o•��o � 2'—s" I I I I I I I I I J �_ � � I NOTE: ANTENNAS ANO SUPPORT ARMS TO BE PAINTED GREEN TO MATCH MONOPINE NEEDLES. 327.10t � � � T.C. � i I / / I / � / ---�' � / 6A I I � I I I il i �f I I , I � . � � N I � � J � � Q MONOPOLE FOUNDATION. TMA — TYPICAL (2) PEF SECTOR. ATdcT PANEL ANTENNAS lYPICAL (4) PER SECTO TWO STACKED RAD CEN' 6 ANTENNAS O RAD CE 6 ANTENNAS O RAD CENTER 58' AGL. SE�TOR "B�� 26�� ANTEN NA P LAN VI EW NOTES: 1. ALL DIMENSIONS SHOWN ARE MINIMUM C�EAR. 2. ELECTRICAL CONTRACTOR TO INCLUDE REMOVAL OF SPOILS. UTILITY TRENCH DETAIL U-Z,U10�0� . _ [•)cG - Z�1O - O `}� �.�'6 ��i w�:��_ 1i2.— ��0—�1 i _M....,..,........- aF�',r::t:sr, :az�..rr � i 327.10t � T.C. I -- _ � S� �� � O, A� Cl, ,� '�<".a�..�� � e<Y��.'�.4_ ��ii3� I' ��'t'" 10 .� �-�, - -- �!D°? 13 .'�s�� ����a7t: � �i�se �i It3� SCALE: NONE � , , � SCALE: � 1 3/8"=1'-0" 0 1' 2' 3' ;Q h� O �u ry � r �� � O, A � $G4LE: � 1 �4"=� �—�" 0 2' 4' FlNISH GRADE , , „ PATCH (E) SURFACE TO MATCH (E) ADJP�ENT SURFACE REMOVED FOR TRENCH WARNING TAPE SAND BACKFILL (90R SCREENED) TAMP TO 95X COMPACTION IN 8' LIFTS, EXCEPT FOR ALL PAVED AREAS USE 2-SACK SLURRY ENCASEMENT. 4'0 SCHEDULE 40 PVC CONDUIT FOR TELCO �2 SOLID BARE GROUND POWER FEEDER OR UTILITY SERVICE. SIZE PER SERVING UTIUTY COMPANY REQUIREMENTS. �J RA Jeifre�r Roms d� Auoctatea� Inc. Architecturo R TelecommunlcaHans 3 San Joaqufn Plaza, Suif� 155 Nswport Bsach, Califomia 92660 Phonr. (949) 760-3929 Fax: (949) 760-3931 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY 8Y NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO ATBcT MOBILITY IS STRICTLY PROHIBITED. STAMP c � a �D ARCj�� .> v R� �> �� * C-020876 * f O �. s F EB. Z�'� ���P qT F OF CA�� PREPARED FOR at&t 4420 Rosewood Drive Pleasanton, California 94588 APPROVALS R.F. ENGINEER DATE SITE ACQ. & ZONING DATE ERICSSON CM DATE AT&T CM DATE I OWNER APPROVAL DATE PROJECT NAME NOVEMBER DRIVE PROJECT NUMBER CN3242-A RESULTS WAY CUPERTINO, CALIFORNIA 95014 SANTA CLARA COUNIY DRAWING DATES 02/10/09 PRELIMINARY ZD REVIEW (P1) O6/08/09 DESIGN CHANGE (P2) 07/02/09 FINAL ZD�S (P3) 01/26/10 SITE RELOCATION (P4) os/i o/i o i oox zo's (PS) OS/21/10 CLIENT COMMENTS (P6) O6/10/10 CLIENT COMMENTS (P7) 08/16/10 PLANNING COMMENTS (P8) 08/23/10 CLIENT COMMENTS (P9) OB/31/10 REVISED ANTENNA COUNT (P10) RFDS REVISION LEVEL 1.6 SHEET TITLE ENLARGED SITE PLAN A-1 � M n 0 �, 0 � W m � � Z U W � 0 a a � ���� � 18' ENLARGED SITE PLAN KEYNOTES 1 EXISTING 6' 0 REDWOOD "SEQUOIA SEMPERVIRENS" TO BE REMOVED. 1A EXISTING BUSHES TO BE REMOVED. 2 EXISTING TREES AND BUSHES, PROTECT IN PIACE. 3 EXISTING CONCREfE CURB. 4 EXISTING ASPHALT PAVEO PARKING. 5 EXISTING TOE Of SLOPE. 6 EXISTING TOP OF SLOPE. 7 EXISTING BLOCK WALL. 8 EXISTING PROPERIY LINE. - ...... --.�""'""".-� ,__.__--_...__._.._.�.�___-�.���0^-0�' 7�-�,p10��1 i V � ' k . � � � � __Lt.�t o. -o?�.- ; +� . . . . � ; ' , �i Q "'� ��_ � � � '� _ , . . . . �_ y ....�. + � - �' ""' ! � ` i �� _` t ..�...,..-.�,� ...�--�. �..� .._�,..�...- -• � �',;:�:! s n < � I __ _ _ _ ___-_.__ ._._�._�+ � Q`O � ._z___, _ QCC.- 2010- O�- i .. �. � '� 1 R.. • _ ;� . ` • ; � - ZolO-3 � ._._ . h,�d`.s�i:..•A:tis�.iesf r i' Sii9i:t,;.f� ��►Pe�s��P�.�3���� 1��T�� � �faCi TREE REMOVAL PIAN II I ; I L / . � ,'�� :. � � ,:; �. � � � � i,' ' , I _ � �� '`:-'I ; ' �Y;� � / � /: ,1 � I � -1 . � I � ' I ,� � I �� � 1�� � � , � � I I � � �: � � I � � � � �, I / I , � I � � �, 1 I � � I � � � � j I � � , � � I � ( I ' i IYP. � N SCALE: � � 1/4"=1'-0" 0 2' 4' �J RA Jeifroy Rome � Aasoctatea, Inc. Architecture R Talecommunicallona 3 Son Jooqufn P�aza, Suifs 155 Nawporf Bsach, Callfomia 92660 Phonr 949 760-3929 Fax: 949 760-3931 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO ATBcT MOBILITY IS STRICTLY PROHIBITED. STAMP � A � Fcs � * C-020876 * `�t � A � s F fB.2�'���a�' I qj £ Q�' CA�� PREPARED FOR at&t 4420 Rosewood Drive Pleasanton, California 94588 APPROVALS R.f. ENGINEER OATE SITE ACQ. & ZONING DATE ERICSSON CM DATE AT&T CM DATE OWNER APPROVAL DATE PROJECT NAME NOVEMBER DRIVE PROJECT NUMBER CN3242-A RESULTS WAY CUPERTINO, CALIFORNIA 95014 SANTA CLARA COUNTY ORAWING DATES 02/10/09 PRELIMINARY ZD REVIEW (P1) O6/08/09 DESIGN CHANGE (P2) 07/02/09 FINAL ZD'S (P3) 01/26/10 SITE RELOCATION (P4) OS/10/10 100� ZD�S (PS) OS/21/10 CLIENT COMMENTS (P6) O6/10/10 CLIENT COMMENTS (P7) 08/16/10 PIANNING COMMENTS (P8) 08/23/10 CLIENT COMMENTS (P9) 08/31/10 REVISED ANTENNA COUNT (P10) RFDS REVISION LEVEL 1.6 SHEET TITLE TREE REMOVAL PLAN A-1.1 � � 0 m 0 � W m � � Z � U w � O a a � — ELEVATION KEYNOTES O 1 PROPOSED ATdcT �6� (2 ANTENNAS PER SECTOR, 3 SECTORS) 5 EXISTING BUILDING. MOUNTED ON A P P MONOPINE. ANTENNA TO HAVE PINE NEEDLES COVERS OVER EACH ANTENNA. ( ) ( 6 EXISTING LANDSCAPING. PROTECT IN PIACE. � MOUN�ED A PR MONOPINE RANTENNA� TO S j�{ E ,qVE� RS) PINE NEEDIES COVERS OVER EACH ANTENNA. 7 FUTURE OTHER CARRIER (9) ANTENNAS 2 PROPOSED AT&T MONOPINE WITH FULL BARK CLADDING. (3 PER SECTOR, 3 SECTORS). BOTTOM OF PINE BRANCHES TO START AT 25�-0" A.G.L. 8 EXISTING BLOCK WALL. 3 PROPOSED 6'-0" HIGH CMU EOUIPMENT ENCLOSURE, WITH CLADDING TO MATCH FUTURE BUILOINGS IN COLOR AND STYLE. 9 EXISTING CONCREfE CURB. O4 PROPOSED AT&T GPS MOUNTED TO EQUIPMENT CABINET. 10 FUTURE CONCRETE CURB. TOP OF (N) AT&T MONOPINE. 74.00 A.G.L. 0 i � n i0P OF (N) AT&T ANTENNAS. ' s�.os ac.�. CENTER OF (N) ATdcT ANTENNAS. 65.00 A.G.L. �, TOP OF (N) ATdcT ANTENNAS. 0 8 A.G.L. CENTER OF (N) ATdcT ANTENNAS. 58.00 A.G.L __..__ - U�- Zo �o- 03 _ _ ; �c c. - Zo� o- oy.. i i " . � � �' �� � '�(�_- ��O 1 O ^ 3 f __ � r:r�:dK,�:: ` i p �+ ^� .. x (� / i d�t �: C. `1�i��t'.e;i t.::�fi!.�j� 1�' ��� � � �tsl! �i1�3t o� � C�r A *cc .� � � 30TTOM OF (N) MONOPINE NEEDLES. z5.00 A.G.L. 0 I in N a� i�; � ���� � ' � � �� �'� v � . �' �` �,a�'' v'`'3� r� � � �''�� '# �, � � k � � � ,��y " � `�` �.� �rv� � rv. ys ' . �I, �� ��,, I � �� ., "� '� �: ,� � , �.w � °..' .� ��� ' �,.�,;, � i �k' '# � ��;-� � I I �: ,,� �, � iw � � ;� Yr �X � '� � ,� � � � �„Y � tii,' a r1'r �g:i:.�t� k: �'� M1 i ., ;N � �• �� � �` � '+� � � ,�.>� � � �� +: ��,� � '"� � ���, � v��i°' -; �.. �, ._ :�.,�, � � � ..�,► r ,� * �, �� ��� "� �z � � ��� � �'3+�'"` � � ,� ,'" .� � �� `c ,c -�' :''1&'1� �t ,.. t�", � '� �!- � � . � w �1 �::� . � � ��, �I I�> � � ,,,y, : 1A � .. ... �3' �� 'f✓�. � � �. � �� �, � � ���, ` ,� » �,, t� ���,� - �.`. k, _ : � ''x ,� �:' .� ..�'�, ,,�'. �; YS "� '` � D; � � � �� '�'. �`r,,; �1 �,,� '� I I.,.�.���ik ,��" �' " i i �''��,.�. � � ��' ,��. < � � I � I � .'. 7 a'" � � r� ,,m � � s' �( , � ' ���/ k.u; ' q .e . .°4 � .�' � p S' � ��,�-��.���" ��� ;,� _ �� . i>� �� �����j �:,,, u' ' jp �'� . �.,�.� � � t � �'-'�� �.;� ,,. ,�; � �, s �, �• � ;� ;� �i ��� �*� �� � s'—o~ i T'.. � � ', \ i- % 3 , >•`��yrt ; +t` 'l ,. ;� �,: r� : �� y ��"-� �� ' ',�r ^� �� fF. . � � i" �`�� , y f iq � 7 " �. ,�� ' ' / TOP OF (N) CMU ENCLOSURE. i�,'i ,� '�.�� t� ��� 0 I � TOP OF F.S. 00.00 A.G.L. 0 � �n TOP OF EXISTING CURB -05.83 A.G.L. f � � i i , ( <° 332.67t F.S. � i i : i i . i � i i 332.00t T.C. ' . �� i 1 (FUTURE) ' -- - ------J - . FUTURE GRADE -�'- - - ------�---- � 10 327.10t T C . ELEVATION KEYNOTES O MOUN�ED D ON T A PR MONOPINE RANTENNA 0 HAV OR5) 5 EXISTING BUILDING. PINE NEEDLES COVERS OVER EACH ANTENNA ( ) 6 EXISTING LANDSCAPING. PROTECT IN PLACE. � MOUN�ED ON A PR D MONOPINE RANTENNA� 0�y ORS) PINE NEEDLES COVERS OVER EACH ANTENNA. 7 FUTURE OTHER CARRIER 9) ANTENNAS (3 PER SECTOR, 3 SECT RS). 2 PROPOSED AT&T MONOPINE WITH FULL BARK CLADDING. BOTTOM OF PINE BRANCHES TO START AT 25�-0" A.G.L. g EXISTING BLOCK WALL. 3 PROPOSED 6'-0" HIGH CMU EQUIPMENT ENCLOSURE, WITH CIADDING TO MATCH FUTURE BUILDINGS IN COLOR g EXISTING CONCRETE CURB. AN D STYLE. O4 PROPOSED AT&T GPS MOUNTED TO EQUIPMENT CABINET. 10 FUTURE CONCRETE CURB. �i ,�. =i�'� ^:i { ;� 7 c,� , } '� .'� aa�� � ,� �, R� � �'- �� ��:, � ulE =t ,� �' � � 4. '"�''.. ,. R „ �_ �_ � �i � � � "�: � ��+. '� �?=,,.� �� -�_� � � , ;� � �„� � � � '°� .c� �� , �` �1� � �, ��"� i i �� '�` s � � I L � . � i; w- +r� ,� y, � } ��. � �d�� � � � �a�� �. " � �::� �; � . �``: � �� ,� ��' ��:����.� �:� , ,_ � � �. ���Y .� e;��k �� � � m��_�: � , � :� �; �v;, �t ��'� s �; � � � �"� ;� _ ��_� ��_ , �� � 'n �° ; �� ��.�: �„� �. -•�, �: 9'-0' i .� � .+ r �: a �� � ��'� � �� �� ='�.. r i` � ,ar�v�, �; ,� s�� ��� TOP OF (N) AT&T ANTENNAS. 67.08 A.G.L. _ CENTER OF (N) ATdeT ANTENNAS. �� TOP OF (N) AT&T ANTEN�NA�S.__���� 60.08 A.G.L. �' CENTER OF (N) AT&T ANTENNAS. 58.00 AG.L. `' ��" � yo,o--0+�- TR-�ao. �, ;,, x'.� �'' � , � ,F, � / • �� � ,�,�. :� ..� � :� ..� s � � � .� '�' _ , ' � 1•��. � � 0 � ��- �'V�"' ',� �'` � . _ .".� _ _. ... _. . � ��� (';�-`" ' .. � : � � � �' � ; J I � � � � '�` , . - ' .. ". C� � � j,�► ""� ���,�� � ��� �, � � . � . • � � . � , .. .�._�.. � ...T..._.. � �-. � �� FF "� r ��� y , � q ,-. ". ` �� M. � '� . � �i` .{..� + °� .. �� r . . r . _...r...+wP^"^"� �""'......_w•n�......i.r..m ., �' �� � ....:s r ,�' �,� �,';�.�"'�° � i �; � � ' +� ;�' " .� ! � �i? �'s� �+ ���. . . � . �` ; � �" %� z' - ._� " a�+'� <. �. .F�! ; � a,. , ' . . . ., n � , , : �, � _._._-� � *„ � � i�'t�s�� 3. :�� :,;��:� �°�� � �� - � s�. r. � .. � � ��. � 34 �t u� _ � � . . �._.,.�..�..�...�.a-.-��„s. i � �. �» � � ��,"��� � ��,�'-� ✓,��� � �, � ",'.- ' '� BOTTOM OF (N) MONOPINE NEEDLES. 25.00 A.G.L. 8 �%� 8 I 6 3 ����A 4 :R.. � � a'!. ,,'� % � ��l � ���� ������ �, � � q� � i �� 1 `".. � }� f a�� / � � �'u 1 J � � V ', i % � � t' .� i�/j ,J , ���� , i ��l / � •�/ � � �� (/ . I �� r � , t *% � F I� �' r�4 , %' ;� � q i y� r � '��"� "� '���r � TOP OF (N) CMU ENCLOSURE. �, �%%� ';, r� �, , 6.00 A.G.L. ,.� � � 332.67t F.S. o ��;����, ' '% i i �° � � 332.00t T.C. TOP OF F.S. , ;� "' % - --- FUTURE �'^ - - - - - - - - � � FUTURE GRADE ,o ELEVATION GRADES BASED ELEVATION GRADES BASED 32�.iof T.c. NORTH ELEVATION 9 OFF FUTURE SITE OFF FUTURE SITE IMPROVEMENTS BY DEVELOPER. IMPROVEMENTS BY DEVELOPER. ' SCALE: 3i,6M—,.—op a�. 2 SOUTH ELEVATION -05.83 A.G.L. 9 00.00 A.G.L. 0 i � TOP OF EXISTING CURB. TOP OF (N) AT&T MONOPINE. 74.00 A.G.L. 0 I iA N �J RA Jeffny Roms � Asaociatea, Inc. Architeciun dc Tel�communicotlona 3 San Joaquln Plaza, Sui1s 155 Nswport Bsach, Calfiornla 92660 Phone: 949 760-3929 Fax: 949 760-3931 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS 5ET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO ATBcT MOBILITY IS STRICTLY PROHIBITED. STAMP � AR(`y� �,� V R � ci � * C-020876 * �t,p ��: Ff B. 20�' P Q Sl � T f � CAU�� PREPARED FOR at&t 4420 Rosewood Drive Pleasanton, California 94588 APPROVALS R.F. ENGINEER DATE SITE ACO. & ZONING DATE ERICSSON CM DATE 0 n � AT&T CM DATE � QWNER APPROVAL DATE SCALE: � 1 3/16"=1'-0" 0 3' 6� PROJECT NAME NOVEMaER DRIVE PROJECT NUMBER CN3242—A RESULTS WAY CUPERTINO, CALIFORNIA 950i4 srwTn cu,w, couNrr DRAWING DATES 02/10/09 PRELIMINARY ZD REVIEW (P1) O6/OS/09 DESIGN CHANGE (P2) 07/02/09 FINAL ZD�S (P3) 01/26/10 SITE RELOCATION (P4) 05/10/10 100% ZD'S (P5) 05/21/10 CLIENT COMMENTS (P6 O6/10/10 CLIENT COMMENTS (P7 08/16/10 PIANNING COMMENTS (PS) 08/23/10 CLIENT COMMENTS (P9) 08/31/10 REVISED ANTENNA COUNT (P10) RFDS REVISION LEVEL 1.6 SHEET TITLE NORTH & SOUTH ELEVATIONS A-2 � M � 0 W s � z � U W � O a a � ELEVATION KEYNOTES O MOUN�ED D ON T A PR MON PINE RANTENNA� 0 HAVE RS) 6 EXISTING LANDSCAPING. PROTECT IN PLACE. PINE NEEDLES COVERS OVER EACH ANTENNA. 7 FUTURE OTHER CARRIER (9) ANTENNAS , 1A PROPOSED AT&T (6) (2 ANTENNAS PER SECTOR, 3 SECTORS) (3 PER SECTOR, 3 SECTORS). MOUNTED ON A PROPOSED MONOPINE. ANTENNA TO HAVE PINE NEEDLES COVERS OVER EACH ANTENNA. g EXISTING BLOCK WALL. 2 PROPOSED AT&T MONOPINE WITH FULL BARK CLADDING, WITH • BOTTOM OF PINE BRANCHES TO START AT 25�-0" A.G.L. 9 EXISTING CONCRETE CURB. 3 PROPOSED 6�-0" HIGH CMU EQUIPMENT ENCLOSURE. CIADDING TO MATCH FUTURE BUILDINGS IN COLOR AND S1YLE. 10 FUTURE CONCRETE CURB. 4 PROPOSED AT&T GPS MOUNTED TO EQUIPMENT CABINET. 11 PROPOSED ACCESS STAIR AND RETAINING WALL. 5 EXISTING BUILDING. �� � U -201p-p 3 -_ i (�cL- 2c1 D O'�" �t �' { $? i�'v't�. � . "� �O ! O - 3 I �., AF �'ia1Ma �ur�VK .��.�iss3C'G �e; ��l��Fl�t'$���vd � � d !D►!! �l�Fl�ttii�� a c,� R ��,�� � 2 � ; , �;w�''. r ,�� , �� � ��`'� '� � �:<�`�, �Y��" �� �, x i w. 'y � � `�.W{i�4'r � � ,� , "a�,m vc?'� �q�;; , '�Y ' �!v � . �i! , {;" > ... �C;y J+ Yt � ` �.t ,,�' �. � �����: x � > �, � � �:; �, �' �� � �� �����'� I I _� � �r.. �� � � �:: a'��. �,�,'� U 1.- � ��,�j�� � a�:.� � a �� �—�-�� . 6 ; � s � �� �..:. r ,- �� ��� ��y � ;�. ._ �i*:�; �4 �� � � f � � ::: � � � �: � x 1� � -�` � � , �;, m ��x ��'�� �` �' � �' '�c� .f � �, r�a' � 1� a �`_� �+.w � _ � �� — — `%"'� `'�`u � �, ,y �`-�`"' ,,�� � '. ��#'"�;�g�.� °�-� �, � ; ^f' if �:,�G -� .t�€', .,..�,.�y, � y, � � '�. �; � , ,� �, ,�.: � �� . � ��, � � � I I I � * .�: e.,�r�.,�`� �� u��,���� . � � r� ��`" � ��� �:�{�,i� �� ��` � � �� u ��a � ;4�: :�r+� �" �.` ��.-:tr`" y �'' �` � � Y' � � ���,���.,�� � � �; ,,> . � �� .� �` >�-� �`'' �r' �`� 'f � — � � :�:�s w iF � _ � t.. �'.;� s���� �"•',!' a� t �. � � ' �` �, _ .....�..�.-�..—r---"-- (z�G'ZO1 Tle�.701�^7✓' 1 F 1�.._ o�o ^Q., . � � .. . R _ . . ; . . 't ,c. . �x T: �.. ;:,, .�,a , q-. ��""'�O _. r .. � �. S .�; �w. . '� . ��,` J �^ --- � r�� �� .s��...... 's:�:T � �� � '�' , ° . _ a,. '' ' '.IrF:� ti.,:.�i: • y: .�. � � k F � � ; � � s 5 '�'' � � �� � �. � � � � vr ,�{ y � � . .. � �'� 9 .� .yR ,� :�� '�' i {'" � i�' �� F *' .,yF` �� � �` ��`� � 3C Y' 'f t ,���� �� ' " , ._ , ,;�,, ,� ,��s , ::�%' f� Yy °, } - �x . - � ��� �. ., ,� �r � � ,', �� � 5 ,< . , ; . ; .� ,: r,. ,. , , v_ � y., , , ,� , � r , , j . . F.: . . ,. � ,' ./ . �� ., t ; � Y , . ., i : �� I „ :' ':' >i . , , . z . ' . , . . . _ . � � _ _ . . . _ _ _ . e,i` � � i ' �;.. r "' ' � . � i f - k . ' .� s , . -. . . � 1 �" t� r �,r- ` 6 � f r x � � `.� � _ 8 3 4 "' � 11 r�-` '' �' �'. � . ; .� , x � l '�� � ._ '`{ f /� �. � r� � 1� F .j { �' �� �:. s�,f r.` ., � ,� f � k r►F � � / ;� � � : f E .y -�f '��� _ , r x � � r.., � �� t , � i . �.. "... :� / � . f /_ / � .'. a ..�a 4 r � , � .�.�� . { ti i � � � �. ° ; « , � �y � � / �., ; .�..,, , .- b,►f J'� f- , Y ' , y d.ia 1 ,� � � �` �J� Y . J - < � �, ��_.� r �.` �--{` f-'-^''-,`;r`m— ^7`�.'-�Y' , �~ � t+ .. i i � ' t tlr �., � °� r;. -" i 332.67t F.S. i ��,f x t ,(_ . ' � � ,e.':e JT�.}� sk rs � n �s .l� � 3 � � i i ..w, .., , s. ., a. ��, z. ,� . � w :��. y -.��� t .�w: f .. � �'� 4 > s $ .n ...c� i '; i 332.00t T.C. F ` , ��'� '� '� y ,4 '� .:,.. 3 �+.+. ,,•`t' • , . _ r � �". t:b" ?` • . �, ��:.. ?'�,� � _ , � „r . . - . .. :. T �� „_,____� , - .,, X� ,�, -- ------ ------ - -------- ------- --- ---- --- --- -- �FUTURE�--- J�° .t.. �, -. 4.. r ,. ^- -- ' -- `- ----- ------------ ------- ------- �W - - _ - _ _ - _ - - - y � �'�� ¢ <.. .:� 4� a �' �, ,. - . , � - � �UTURE GRAOE r . ,�.; . . ,. { :�. � . t .� � � � �" ` � .. `fa : , , .., :, � �, � �`'� � �. rt ` � : '. � � w 327.10t T.C. , � . ..k ' ` �' <, , ,, �..: _ • �'; � a . . . ...� t y4c.�" � 0 n�! fi . "'.."�..:� _ . • , - , , , . , FxisTiNr, r,RanF EAST ELEVATION 9 TOP OF (N) AT&T ANTENNAS. 67.08 A.G.L. _ CENTER OF (N) AT&T ANTENNAS. �� �.J RA Jeffre�r Rome � Asaoclatea� Inc. Architecturs d� Telscommunications 3 San Joapuin Ploza, Suit� 155 Nswpo�t Bsach, Califomia 92660 Phone: 949 760-3929 Fax: 9493 760-3931 TOP OF (N) AT&T MONOPINE. 74.00 A.G.L. TOP OF (N) AT&T ANTENNAS. 60.08 A.G.L. CENTER OF (N) AT&T ANTENNAS. 58.00 AG.L. BOTTOM OF (N) MONOPINE NEEOLES. 25.00 A.G.L. 0 I in N TOP OF (N) CMU ENCLOSURE. 6.00 A.G.L. 0 I i� TOP OF F.S. 00.00 A.G.L. 0 � � TOP OF EXISTING CURB. -05.83 A.G.L. . c 1 O ^ I �p �n � 0 I � N PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO ATBcT MOBILITY IS STRICTLY PROHIBITED. STAM P c �NSED ARCy� �; ��'l Rp� �i * ' C-020876 * �� � A � s F fB. 2�� ��P ql F OF CAUE�� PREPARED FOR � at&t 4420 Rosewood Drive Pleasanton, California 94588 APPROVALS R.F. ENGINEER DATE SITE ACQ. & ZONING DATE 0 I � ERICSSON CM DATE � ELEVATION GRADES BASED OFF FUTURE SITE IMPROVEMENTS BY DEVELOPER. SCALE: � � 3/16"=1'-0 0 3' 6' AT&T CM DATE OWNER APPROVAL DATE PROJECT NAME NOVEMBER DRIVE PROJECT NUMBER CN3242-A RESULTS WAY CUPERTINO, CALIFORNIA 95014 SANTA CLARA COUNlY DRAWING DATES 02/10/09 PRELIMINARY ZD REVIEW (P1) O6/08/09 DESIGN CHANGE (P2) 07/02/09 FINAL ZO'S (P3) 01/26/10 SITE RELOCATION (P4) OS/10/10 100% ZD�S (P5) 05/21/10 CLIENT COMMENTS (P6) O6/10/10 CLIENT COMMENTS (P7) OS/16/10 PIANNING COMMENTS (P8) 08/23/10 CLIENT COMMENTS (P9) 08/31/10 REYISED ANTENNA COUNT (P10) RFDS REYISION LEVEL 1.6 SHEET TITLE EAST ELEVATION A-3 M n 0 rn 0 � m � � Z � U W � 0 a a � , Title Report #1 PREPARED BY: FIRST AMERICAN TITLE COMPANY ORDER NO.: 0714-3327625 DATED: JUNE 23, 2009 Legal Description REAL PROPERTY IN THE CITY Of CUPERTINO, COUNTY OF SANTA CLARA, STATE OF CALIFORNIA, DESCRIBED AS FOLLOWS: PARCEL A: ALL THAT PORTION OF SA10 LAND AS DESCRIBED AS ADJUSTE� PARCEL 3 AS SHOWN IN THAT CERTAIN LOT LINE ADJUSTMENT RECORDED SEPTEMBER 11, 2001 AS DOCUMENT N0. 15B62177 AND AS FURTHER DESCRIBED BELOW: BEINC ALl OF PARCEL 3, AS SHOWN UPON THAT CERTAIN PARCEL MAP WHICH UAP WAS FILED FOR RECORD IN THE OFFICE OF THE RECORDER OF THE COUNTY OF SANTA CLARA, STATE OF CALIFORNIA ON APRIL 12, 1979 IN BOOK 439 OF MAPS AT PACES 12 AND 13 AND BEINC A PORTION OF iH AN RI I TH T E L DS DESC BED N A CERTAIN DOCUMENT RECORDED OCTOBER 14, 1975 IN BOOK 8662 AT PAGE 46 IN THE OFFICE OF THE RECOR�ER OF SANTA CLARA COUNTY AND BEING MORE PARTICULAR�Y OESCRIBED AS FOLLOWS: BEGINNINC AT THE SOUTHWESTERLY CORNER OF SAID PARCEL; THENCE ALONG THE WESTERLY LINE OF SAID PARCEL NOR7H 00' 01' 00� WEST 241.44 FEET TO THE SOUTHWESTERLY CORNER OF THE lANDS DESCRIBED IN SAID BOOK 8662 AT PAGE 46; THENCE ALONC THE WESTERLY LINE OF SAID LANDS NORTH 00' 00' 33' WEST 318.23 FEET; THENCE SOUT}i 89' S6' 46' EAS 274.02 FEET TO THE EASTERLY LINE OF SAID �ANDS; THENCE ALONG SAID LINE SOUTH 19' O6 48' EAST 335.47 FEET TO TNE NORTHEASTERIY CORNER OF SAID PARCEL; THENCE ALONG TH EASTERLY LINE OF SAID PARCEL SOUTH 19' O6' 48' EAST 293.23 FEET TO THE SOUTHEASTERL CORNER OF SAID PARCEL; THENCE ALONC THE SOUTHERLY LINE OF SAID PARCEL NORTH B2' 2' 51" WEST 261.05 FEET; THENCE CONTINUINC ALONC SAID LINE NORTH 89' S7' 24" WEST 220.9 FEET TO THE POINT Of BEGINNING. PARCEL 8: PARCEL 2, AS SHOWN UPON THAT CERTAIN PARCEL MAP WHICH MAP WAS FILED FOR RECORD I THE OFFICE Of THE RECORDER OF THE COUNTY OF SANTA CLARA, STATE OF CAUFORNIA ON APRIL 12, 1979 IN BOOK 439 OF MAPS AT PAGES 12 AND 13. Easements #1 4O EASEMENT FOR PUBLIC SERVICE AND SANITARY SEWER AS SHOWN ON PARCEL MAP RECORDED IN BOOK 407, PAGES 28 & 29 OF MAPS. (PLOTTED HEREON) O EASEMENT FOR PUBLIC SERVICE AND SANITARY SEWER AS SHOWN ON PARCEL MAP RECORDED IN BOOK 439, PAGES 12 Ac 13 OF MAPS. (PLOTTED HEREON) 16 EASEMENT FOR INGRESS, EGRESS, ACCESS AND PARKINC FOR VEHICULAR AND PEDESIRIAN TRAFFIC RECORDED AS DOC. N0. 16105737, D.R. (BLANKET IN NANRE) 17 PEOESTRIAN PATH EASEMENT RECORDED AS DOC. N0. 16334779, O.R. (PLOTTED HEREON) , Title Report #2 PREPARED BY: FIRST AMERICAN TIRE COMPANY ORDER NO.: 0 71 4-3430588 DATED: DECEMBER 14, 2009 Legal Description REAL PROPERTY IN THE CITY OF CUPERTINO, COUNTY OF SANTA CLARA, STATE OF CALIFORNIA, DESCRIBED AS FOLLOWS: PARCEL A, AS SHOWN UPON THAT CERTAIN PARCEL MAP WHICH MAP WAS FlLED FOR RECORD IN THE OFFICE Of THE RECORDER OF THE COUNTY OF SANTA CLARA, STATE OF CALIFORNIA ON JANUARY 23, 1980 IN BOOK 479 Of MAPS AT PAGE 1. Easements THERE ARE NO EASEMENTS LISTED IN THE EXCEPT10N5 OF SAID TITLE REPORT A2. Assessor's Parcel Nos. 357-20-041, 357-20-046 Qc 357-18-035 Geographic Coordinates at Proposed Monopine 7983 DATUM: LATITUDE 37' 19' 10.18� N L�NGITUDE 122' 03' 09.82" W 1927 DATUM: LATITUDE 37' 19' 10.39' N LONGITUDE 122' 03' 05.96' W ELEVATION = 334.5 FEET ABOVE MEAN SEA LEVEL (A.IA.S.L.) CERTIFICATION: 1HE LATITUDE AND LONGITUDE SHOWN ABOVE ARE ACCURATE TO NITHIN +/- 15 FEET HORIZONTALLY AND THAT 1HE ELEVATIONS SHOWN ABOVE ARE ACCURATE TO NATHIN +/- 3 FEET VER7ICALLY. iHE HORIZONTAL DANM (GEOGRAPHIC COORDINATES) IS W TERMS OF TNE NORTH AMERICAN DATUM OF 1983 (NAD 83) AND IS EXPRESSED IN DEGREES ('), MINUTES (') AND SECONDS ('), TO iHE NEAREST HUNDREDiH OF A SECOND. THE VERi1CAL DAlUM (ELEVAlIONS) IS IN 7ERIAS OF THE NORTH AMERICAN VERTICAL DAlUM OF 1968 (NAVD 68) AND IS DETERMWED TO 1HE NEAREST TENTH OF A F00T. Basis of Bearings 711E STATE PLANE COORDINA7E SYSIEM DF 1983 (NAD 83), CALIFORNIA ZONE 3. Bench Mark 7HE CALIFORNIA SPATIAL REFERENCE C.O.R.S "P213', ELEVATION = 656.17 FEET (NAVD 88). Date of Survey JANUARY 20, 2D10 ;; �;; �� ANTENNA ;; � � . r ;, �%;; ';; %� '; � EXISTING BUILDING ii: ''%' ii; �i; ��. ��, .�, i,, �,ii , ;i; i�; EXISTING BUILDING %ii „� ,,,,,, � �i' ';i; �iii �i„ "���iii;;;� • %� i;; i„ i �i� ii� �ii ��� � ' I i;; '�� �„ �;5; . . T /; �ii����i:iii���iiii�iiiiiiiii�iiii:iiii�i�/ I 349•49TOP - CANOPY Z - 9.4 T P �L 343.55TOP 336.11Fq 335.B4FS u' ------------ N -- WE 150. 00 --------- -----------� ---------------- � � NI � .145.44TOP CP� GP� �P�GP� � GP. a �p� � 3J6.79F5 336.40F CP. EC Q 336.99FS �• 343.23FS -_ - - 337ABFS � iii �� ii iiiii' iiii iiiiii�� ii �iiiiii / �iiiiiiiiiii���iiiii' � �,,,, ��,,,. .�,,, �,,,,, �,,, ��, ii% 351.70i0P � iii. i�i. iii, �ii, ;;;; AT PROPOSED MONOPINE i�� ;�;� GEOGRAPHIC COORDINATES %,�; LAT.= i 37'19�10.18"N �NAD 83; �'� LONG.= '122'03'09.82"W i;� /ii; �'�� EXISTING BUIIDING iii, ji: ,;;; � � (LOWER ROOF) � (UPPER ROOF) �� ii� i i/, i j iii; ;��� :� , ,; ., � , i i ,�� iii i;j � ," ! r ': � ��!���i� � ���ix�� �����i ii::;!!�� (-� L - 2.01 O-- O'-t AP#''T",�'�1;��.. �-?oa o -3+ �;�e1'oae ��i+aol�h' �����zr���� �'�F�;��a:�����a 4-t� /o �}OSf O V UE Sa�natit� `� _ �asc Ristn r 334.49TC Lease Area Detail SCALE: 1"_p0' � � � � � � - � 333.63FS � � � u � z � Y = � � - -.-�-_- � e _._�.,. _. ^r � I 351.26TOP � � J � PROPOSED ATAcT � I I 5' WIDE UTILITY ROUTE 32.22N ��}51.37F5 o � � 331.89TC I m I 356.13TOP � I � 334.3 � I 331.07TC 332.16TC z 4 n 330.B6TC ,,, -„- , �i: EAS�: I332.33TOE 330.82FS % o _ , � - � ° n � ' �' � 358.38TOP N � iii ~ 335.45NG� POINT'�A� - - - � i;i � t m. ' � WEST � 330.62TC iii � � - '�� � ' � .��c � ' � ';; o 30.00_. '�ii PROPOSED c' a � I i�i ATAtT � � � 358.SOTOP /ii 42.5'x22' ' � � � �;; LEASE AREA � x I � I � L � < � :;; wESr.� a , � �� � ��; � 22.00' POINT "8' I � a 'i%i � 355.OBTOP � ��� 3}1.99T __ � iii � � 330.27TC /ii � // �� .. . _.. _. I � ii � � ,,, I C� PROPOSED ATkT 12' WIDE ' $ � I NON-EXCLUSIVE ACCESS ROUTE � v� •3�D.15F m i� � 330.93NG I I g '��' I � � 357.36TOP 330.75TC I � 330.22?C I I )P I �!, � � , I I o� � � � 33093NG I Z � � z . __ . 33� .13F I � ' . 7T P I � a . � I � � � I ti a3o.z�rc -- fi ----- 335.78NC�' _ ? _ � � 364.D3TOP � � I 3 � . ........... a � � 330.9 NG� � I � � �� ___ I 6 I fi I � m - I I � 330.91 C . I � . 330.16FS I � _ __ � I � . P � � � � � ' 330.91TC I � � � 330.�9TC � Access Route 5 � a THAT PORTION OF IAND IN THE CITY OF CUPERTINO, CWNTY OF SANTA CLARA, STATE OF I 35B.46TOP � i 33D.81TC CALIFORNIA, AS �ESCRIBED AS ADJUSTED PARCEL 3 AS SHOWN IN THAT CERTAIN LOT LINE � I ADJUSTMENT RECORDED SEPTEMBER 11, 2001 AS DOCUMENT N0. 15862177 TOCETHER WITH I � I I THAT PORTION Of PARCEL 2, AS SHOWN UPON THAT CERTAIN PARCEL MAP WFiICH MAP . �� I I WAS FILED FOR RECORD IN THE OFFICE OF THE RECORDER OF SAID COUNTY ON APRI� 12, ' 335.00ryG I L___ 1979 IN BOOK 439 Of MAPS AT PAGES 12 AND 13, BEING A STRIP OF LAND, 12.00 FEET i � -------- NADE, LYING 6.D0 FEET ON EACH SIDE OF THE FOLLOWINC DESCRIBED CENTERLINE: � � - -- I 3�5.83NC i COMMENCING AT THE MOST SOUTHERLY CORNER OF SAID PARCE� 2, SAID POINT BEING ON A CURVE CONCAVE SOUTHEASTERLY, HAVING A RADIUS OF 367.00 FEET, A RADIAL LINE L______________ THROUGH SAID POINT BEARS N67'23'21'W, SAID CURVE ALSO BEING THE NORTHWESTERLY RICHT OF WAY OF BUBB ROAD AS SHOWN ON SAID MAP; THENCE NORTHEASTERLV ALONG 331.65TC SAID CURVE, THROUGH A CENTRAL ANGIE OF 12'45'S0', AN ARC DISTANCE OF 86.21 FEET I TO THE POINT OF BEGINNING; THENCE N55'35'21'W, 363.76 FEET; THENCE NORTH, 67.74 f : 335.52f�C FEET, THENCE EAST, 207.88 FEET, THENCE N18'19'01'W, 727.27 FEET, THENCE WEST, 311.34, THENCE NORTH, 166.54 FEET; 1HENCE WEST, 30.00 FEET TO A POINT HEREINAFTER I REFERRED TO AS POINT "A' AND THE END OF SAID STRIP. w 336 57F5 I z � 334.11FS�y w �VI Lease Area g � � i BEGINNING AT POMT 'A" AS DESCRIBED ABOVE; THENCE SOUTH, 17.25 FEET TO A POINT � HEREINAFIER REFERRED TO AS POINT 'B'; THENCE CONTINUING SOUTH, 4.00 FEET; iHENCE � I WEST, 22.00 FEET; THENCE NORTH, 4250 FEET; THENCE EAST, 22.00 FEET; THENCE 3 SOU1H, 21.25 FEET TO THE POINT OF BEGINNWG. y o I CONTAINING 935 SQUARE FEET, MORE OR LESS. m Utility Route I BEING A SiRIP OF IAND, 5.00 FEET WIDE, LYING 2.50 FEET ON EACH SIDE OF iHE FOLLONING DESCRIBED CENTERLINE: BEGINNING AT POINT 'B� AS DESCRIBED ABOVE; iNENCE EAST, 5.00 FEET; 1HENCE NOR1H, 84.00 FEET; THENCE WEST, 150.00 FEET; THENCE 567'07'S4"W, 72.25 FEET TO 7HE END OF SAID STRIP. I I � _ h Q � 342.40F5 ��;i' i ii, w ii Z ��/ U Q ii z ii o n /� ii � ,, m ,,. ;� _ i, �'' � i. i, - � w '�; ii i ii. ii, ii; ,,, ,,, „ � �, ��; � _ LOMITA AVENUE _ � � _ _ � I I I I � I ----J 71T I 33 .S6F5 I � � I . I I � FD MON. WELL I PER P.M. 284/35 � _ OLIVE ' AVENUE FD 2` BRASS DISK � NO REFERENCE _ �I _ _ � I Z I ,I � I I - Q S�ee� Lease Q Ar�aLDetail ti WI 5 � �- - - I � I- - - I I FS FINISN SURFACE NC NATURAL GROUND � POWER POLE � RETAIN/NC/BLOCK WALL EC ELECIRIC CAB/NET � CONCREIE PAVEMENT PINE 1RfE TRE£ TC TOP OF CURB - -- PROPER7Y UNE Yr WROUCHTIRON FENCE - � CHAIN LINK FENCE '^ � CA TE TR 1RANSFORMER TOP TOP OF 51RUCTURE A CEODEnC COORDINATES TOE TOE OF SLOPE � FIRE HYDRANT/FlRE g EM ELECTRIC MEIER � ELEC7RIC VAUCT LME TABLE N0. BEARINC DISTANCE L1 WEST 150.00' �z seiro�'sa �z.zs' L3 SOUTH 4.00' L4 EAST 5.00' �� ��� �� BIOCK WALL f� PROPOSED ATkT � 5' WIDE UTILITY ROUTE '�i � � PRO�SED ATdcT A� 42 5� 22� LEASE AREA Boundary Detail SCALE: 1'=100� � �� m 3^ � � } : _• O I �, ` � W � 3osoo� 3 0 �C E �' 1 i I � O I P AR 0 P PR �� a N I Ju � PO�V� ZO�� V( , _ � � o � �O j � , g62��� 1 � � � - - RE� NO• 15 - '.� I �N`'Z . 1 -i �O � �9-�� GRAPHIC SCALE ''� L sL _ NP � N - 311_34 ___ ioo o so ioo `I� I---- �-----------� q ��� �` FEET I �� - � _ J ���` 5 \ � ,� EXISTING BUILOING \ � \� - - �7 \\ ` � � ��\� \ ' EXISTING T 343.38F5 BUILDINC � � 343.B3F5' \�� � \ \� �� � ` � ExisnNC aui�iNC ���\ � � \� \� \ \\ \ \� � PPR�'�Z��� ���`� \� PN � �� M' � \ � � \ \ \ \ � � � A RGE� M �2 �� 3 ��\`� \`�. P n/ � g q ,39 / � �\ \'�► P. � f� PROPOSED AT�T 12' WIDE � \ NON-EXCLUSIVE ACCESS ROUTE \� ' ��\� \� I �� \\ \� � \ r- �q$1 - - _- - 207_BB'� � _� =�i i/ -------- ` --�� -- o� � -� \ �.�' � N \ \� I ��►, ��\ �. 4 5 \ \ ,�t� I � \ �� � I ��S'G ��� � I �� �T�; � \ P.O.B. \ 1r/4.�' � \ ��s ' � I �1Y� ��\� I pA RGE� � � �,�,`��z I �� j 7�'� �7Eylba' / +' �,,.��.....,..�...� � .�._...._._-�--_ _ . ...�:�+-�--�.�,.�__ �..�, �NS� �...�._.. ���-��O ^ D � I • � � ✓• R,q� �'W / @ � � ' � �� ^ O� w. P.O.C. Q X Q 4 I ! �•.:,.;.: �/ -I � � C� �f . .. � g-��-1� � m I S F�� , . .. . _ ... , . • ��J _ . ."-'. .,..�..�.._.._ li m � � _ _ �' �� �;=: �-�... ;f �_.� ^� - 1 - ..� = _ _ / - - �- McCLELLAN � ROAD }�'��- � - - - - - - - - -- - - - - b t ' �' . _ _,,_ 9 �..F..:6 ri3:at�:'�� �J RA Jeffrey Rome dc Associates, Inc. Architecture Ac Telecommunicatlons 3 San Joaquin Plaza, Suite 155 Nswporf Beach, CalHornia 92660 Phone: (949) 760-3929 Fax: (949) 760-3931 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO ATBcT MOBILITY IS STRICTLY PROHIBITED. CONSULTANT ��� ���� SUf�VEYIN6, INC. 411 Jenla Cir., SuiM 205, Co�vna, CA92880 Phone.951-280-9960 Fez:951-280-9746 Toll Free: 800-CALVADA www.caNeda.mm JOB N0. 10042 PREPARED FOR at&t 4430 Rosewood Drive Pleasanton, California 94588 APPROVALS R. F. DATE SAC AND ZONING DATE ERICSSON CM DATE ATdcT CM DATE OWNER APPROVAL DATE PROJECl NAME ', NOVEMBER Df�IVE PROJECT NUMBER CN3242-A , RESULTS WAY I CUPERTINO, CA 95014 SANTA CLARA COUNTY DATE DESCRIPTION BY 01/22/10 PRELIMINARY MN 04/14/10 TITLE REPORT / FINAL RAS OS/21/10 ACCESS EASEMENT UPDATE GPH SHEET T�TLE TOPOGRAPHIC SURVEY ��� C-1 ( SHEET 1 OF 1 / \ / / City of Cupertino , , , 10300 Torre Avenue Cupertino, CA 95014 (408) 777-3251 C U P E�T 1 N O FAX (408) 777-3333 Community Development Department September 16, 2010 Dave Yocke Trillium Telecom 7901 Stoneridge Dr., Suite 503 Pleasanton, Ca, 94588 SUBJECT: PLANI�TING COMMISSION ACTIC>N LETTER - U-2010-03, EXC-2010-04, TR-2010-31 This letter confirms the deci.sion of the Planning Commission, given at the meeting of September 14, 2010, approving a Use Permit to allow the construction of a personal wireless service facility, consisting of a 74-foot tall monopine with twelve panel antennas and associated base equipment; approving a height exceptior. to allow antennas to be mounted on a monopine at a height of about 67 feet or less; approving t1e removal and replacement of up to four Coastal Redwood trees associated with the installatio�i of a proposed personal wireless service facility, located at the Results Way office complex, accc�rding to Plannulg Comxnission Resolution No.(s) 6604, 6605 and 6606. � Please be aware that if this Permit is not u� ed withixi a two-year period, it shall expire on September 14, 2012. Also, please note that an appeal of this decisicm can be made within 14 calendar days from the date of this decision. If this happens, you w ill be notified of a public hearing, which will be scheduled before the City Council. Sincerely, � ...� ..�► � colin Jung Senior Planner Planning Department Enclosures: Resolution 6604, 6605, 6606 CC: ECI Two Results, LLC, 1301 Shoreway Rd, Suite 2 S0, Belmont, CA 94402 Allen Wong, 10170 imperial Avenue, Cupertino, C�� 95014 g:/pianning/post hearing/actionlefterU-2010-03, EX C-2010-04,TR-2C 10-31 U-2010-03 � CITY OF CUPERTINO 10300 Tc�rre Avenue Cupertino, (:alifornia 95014 R�SOLUT:=ON NO. 6604 OF THE PLANNING COMMISSION OF THE CITY OF CUPERTINO APPROVNG A USE PERMIT TO ALLO�'V THE CONSTRUCTION OF A PERSONAL WIRELESS SERVICE FACILITY, CONSISTING OF A 74-FOOT TALL MONOPINE WITH TWELVE PANEL ANTENNAS �.ND ASSOCIATED BASE EQUIPMENT AT THE RESULTS �'VAY OFFICE PARK SECTION I: FINDINGS WHEREAS, the Planning Commission of the City of Cupertino received an application for a Use Permit, as described in Section II. of this Resolution; and WHEREAS, the necessary public notices have been given in accordance with the Procedural Ordinance of the City of CupE rtino, and the Planning Commission has held one or more public hearings on this matte:�; and WHEREAS, the applicant has met the burden of proof required to support said application; and has satisfied the followin;; requirements: 1) The proposed use, at the proposed lo��ation, will not be detrimental or injurious to property or improvements in the vicir�ity, and will not be detrimental to the public health, safety, general welfare, or conv �nience; 2) The proposed use will be located anc� conducted in a manner in accord with the Cupertino Comprehensive General Plan, the Wireless Facilities Master Plan, the Wireless Communications Facilities Or dinance and the purpose of this title. 3) That the operation of the facility will comply with federal safety standards for radio frequency radiation emissions. NOW, THEREFORE, BE IT RESOLVED: That after careful consideration of maps, facts, exhiUits, testimony and other evidence submitted in this matter, the application f��r Use Permit is hereby approval, subject to the conditions which are enumerated in this r esolution beginning on Page 2 thereof; and Resolution No. 6604 U-?010-03 September 14, 2010 Page 2 ' That the subconclusions upon which tr_e findings and conditions specified in this resolution are based and contained in the public hearing record concerning Application No. U-2010-03 as set forth in the Minu1:es of the Planning Commission Meeting of September 14, 2010 and are incorporated k y reference as though fully set forth herein. SECTION IL• PROJECT DESCRIPTION Application No.: U-2010-03 Applicant: Dave Yocke (for AT&'I' Mobility) Property Owner: ECI Two Results, LLC Location: Results Way SECTION III: CONDITIONS ADMINIST�:RED BY THE COMMUNITY DEVELOPMENT DEPT. 1. APPROVED EXHIBITS Approval is based on Exhibits titled: "�.t&t/ CN3242-A/ November Drive/ Results Way/Cupertino, California 95014" prepared by Jeffrey Rome & Associates, Inc. dated 08/31/10 and consisting of seven sheets labeled T-1, A-0 through A-3, A-1.1 and C-1, except as may be amended by the conditions contained in this resolution. 2. NOTICE OF FEES, DEDICATIONS, RESERVATIONS OR OTHER EXACTIONS The Conditions of Project Approval set forth herein may include certain fees, dedication requirements, reservation r��quirements, and other exactions. Pursuant to Government Code Section 66020(d) (1), these Conditions constitute written notice of a statement of the � izlount of such� fees, and a description of the dedications, reservations, ana other exactions. You are hereby further notified that the 90-day approval period in wluch you inay pr��test these fees, dedications, reservations, and other exactions, pursuant to Governm�nt Code Section 66020(a), has begun. If you fail to file a protest within this 90-day ��eriod coinplying with all of the requirements of Section 66020, you will be legally ba �red from later challenging such exactions. 3. COLOCATION OF ANTENNAE The treepole shall be structurally d�signed to accommodate the collocation of additional antennae from other wirele�cs carriers. The co-location agreement shall be at market rates witll reasonable compensation to the mast owner. 4. ABANDONMENT If after install�tion, the aerial is not u�,ed for its permitted purpose for a continuous period of 1� months, said aerial anc associated facilities shall be removed. The applicant sh�ll bear the entire cost of ciemolition. Resolution No. 6604 U-?010-03 September 14, 2010 Page 3 ____------___________________________----------_____________________________ 5. EXPIRATION DATE This use permit s11a11 expire ten (10) years after the effective date of the permit. The applicant may apply for a renewal of the use permit at which time the Planning Commission may review �the state of wireless communication technologies, camouflage techniques and maintenar�ce to determine if the visual impact of the aerial facility can be reduced. 6. TREE POLE APP�ARANCE AND MAl NTENANCE The applicant shall use a sufficient r umber of artificial branches to obscure the appearance of the panel antennae and ��ny associated mounting framework. The top portion of the tree pole shall have brarches of varying length to give the tree pole a conical form. Panel antennae mounted away from the mast shall have needle covers to blend with the bree�l foliage of the artificial branches. The mast shall be wrapped with a faux bark and any antenna mounted close to the mast shall be painted brown to mimic a tree trunk. The foliage shall have a mottled green coloration. The building permit shall be review��d a7zd approved to the satisfaction of the Community Development Director tc� ensure the above condition is met. The applicant sh�ll perform regular mai:�tenance of the tree pole to maintain its appearance and obscure the panel antennae from public view. 7. E UIPMENT EL�TCLOSURE The base equipment enclosure shall be c�onstructed of high quality materials and/or be screened vy appropriate landsca}�ing as determined by the Director of Community Development. The final enclosure desi€;n, wall treatment/color and screening strategy shall Ue reviewed and approve � by the Director of Community Development prior to issuance of build: ng permits. S. TREE REPLACEMENT The removed trees are to be replaced w th three (3) 24" box Coastal Redwoods in the northwest corner of the property. Final locations shall be reviewed and approved by the Director of Community Developme Zt prior to issuance of building permits. Applicant shall provide a letter fr�m a landscape architect, certifying that the newly planted trees are in �ooci health and thE irrigation system is operating properly to maintain tl�e trees. ln addition, the final landscaping plan shall confirm that the existing irri�ation systems are operatinr; properly in order to service the existing and new trees in the area. 9. TESTING OF P AD]O FREQUENCY (R ? L) EVELS Radio frequency levels will be monitorE�d and tested annually for a period of three (3) years from the date of the final occupancy a�proval. The result of these tests will be made avail�Ule to thc Planning Departrlent and the FCC for review. The City Resolution No. 6604 . U-?010-03 September 14, 2010 Page 4 reserves the right to perform code enfotcement actions and/or revoke this use permit if the results sllow RF levels inconsistent with the federal standards. PASSED AND ADOPTED this 14th day oE September 2010, at a Regular Meeting of the Planning Commission of the City of Cupe_�tino by the following roll call vote: AYES: COMMISSIONEPS: Chair B� ophy, Vice Chair Lee, Giefer, Kaneda NOES: COMMISSIONEP.S: Miller ABSTAIN: COMMISSIONERS:I�tone ABSENT: COMMISSIONrRS: ��ione ATTEST: APPROVED: /s/Aarti S11riv�isl . [s/Paul Brophy Aarti Shrivast�va Paul Brophy, Chair Community Development Director Planning Commission G:/planning/pdi•eport/res/2010/U-20f0-03 res.doc U'�OtO A -; s l9/��-'�� i�".. .�.-.�_. E r±.... t�� 1 .._.�.:� �.... _�.. _. ,4��.a,.`........_, i .. ,uw, �i�r����n� ����•��ss�s�n�t �i- i y�- � o �tsit Si�nature \ Cstsc u�;�� - SPECIAL INSPECTIONS 1 CONCREfE 2 BOLTS INSTALLED IN CONCRETE 3 CONCREfE MOMENT-RESISTING SPACE FRAME 4 REINFORCING STEEL AND PRESTRESSING STEEL 5.1 ALL STRUCTURAL WEIDING 5.2 WELD TESTING DUCTILE MOMENT-RESISTIN6 STEEL FRAME 5.3 WELDING REINFORCING STEEL 6 HIGH-STRENGTH BOLTING 7 STRUCTURAL MASONRY 8 REINFORCED GYPSUM CONCRETE 9 INSULATING CONCREfE FILL 10 SPRAY-APPLIED FIREPROOFING 11 DEEP FOUNDATIONS (PILING, DRILLEO dc CAISSONS) 12 SHOTCRETE 13.1 VERIFY SOIL CONOITIONS ARE SUBSTANTIALLY IN CONFORMANCE WITH THE SOIL INVESTIGATION REPORT 13.2 VERIFY TFiAT FOUNDATION D(CAVATIONS EXTEND TO PROPER DEPTH AND BFARING STRATA 13.3 PROVIDE SOIL COMPACTION TEST RESULTS, DEPTH OF FlLL, RELATIVE DENSIIY, BEARING VALUES 13.4 PROVIDE SOIL EXPANSION TEST RESULTS, EXPANSION INDEX, RECOMMENDATIONS FOR FOUNDATIONS, ON- GRADE FLOOR SUB DESIGN FOR EACH BUILDING SITE 14 SMOKE CONTROL SYSTEM 15 SPECIAL CASES (DESCRIBE) 16 OFF-SITE FABRICATION OF BUILDING COMPONENTS 17 OTHER SPECIAL INSPECTIONS AS REQUIRED BY DESIGNER VICINITY MAP �NAAr'QIJEST � .._ , ,� e C�.�.,..� .,.-���Cc �.,.�.: � $.. �:��, , .,..... „ Rifnd� CE '� � � �, p- , � 4: , e . ' t � s .; ., � GraRwda_xve � , � ... ... . . X : � �. „ ,. �ti W :,�4, . . � "; L.ommltaa Ave ; s � � , _ ., a r ?� s �: � �`; : � � �; � _.._ �' � �.... '+��- {5�e�nve Sl�l � �......:; �'' ,': rc � �,�� . .. .,,. � ': k : � K , M s, � �_ � _ a ATcazav Ave K _ � '� ' r ' � r _ � '���� i ; ,�OiDR2AC.�. .� . /�' _... , ..� �_ .�,.,�,,,,,�,�, ,. � , ,. ,,, . ._ . , .,, ,�__,. � �:.� : ,� . ,.: 2 8 POuest 1nc . . . f5 `;. _.. � a Map Cra+A R'� 2008 Nl,V�EO a 7r4�AdNa r CUPERTINO • � � C N 3242-A NOVEMBER DRIVE RESULTS WAY CUPERTINO, CALIFORNIA 95014 CONSULTANT TEAM CLIENTS REPRESENTATNE: ERICSSON INC. 6160 STONERIDGE MALL ROAD SUITE 400 PLEASANTON, CALIFORNIA 94588 CONSTRUC110N MANAGER: TIM LENCIONI PHONE: (916) 437-9119 11\ILLIUM VVI`IJIJLI ll�V 5912 BOLSA AVENUE; SUITE 202 HUNTINGTON BEACH, CALIFORNIA 92649 PHONE: (714) 799-2000 SITE ACQUISRION dc ZONING: TOM JOHNSON PHONE: (714) 206-2879 RF ENGINEQt: HAKAN BATIKHAN (AT&T) PHONE: (925) 300-6919 ARC H ITECT: JEFFREY ROAIE AND ASSOCIA7ES 3 SAN JOAQUIN PLAZA SURE 155 NEWPORT BEACH, CALIFORNIA 92660 PHONE: (702) 324-4338 FAX: (949) 760-3931 CONTACT: ROBIN NELSON LAND SURVEYOR: CAL VADA SURVEYING, INC. 411 JENKINS CIRCLE, SUITE 205 CORONA, CALIFORNIA 92880 PHONE: (951) 280-9960 Fp(: (951) 280-9746 COPlT/�CT: RAMON GONZALEZ DEV�LOPMENT SUMMARY APPLICANT: AT&T MOBILITY 4420 ROSEWOOD DRIVE PLEASANTON, CAUFORNIA 94588 OWNER: ECI iW0 RESULTS LLC. 1301 SHOREWAY ROAD; SUITE 258 BELMONT, CALIFORNIA 94002 CONTACT: ANDREW BROWN PHONE: (650) 292-4100 OTHER ON-SfTE TELECOM FACILITIES: NONE PROJECT ADDRESS: ASStSSUFiS NAFZCEL NUMBER: IATITUDE: LONGITUDE: LAT/LONG TYPE: EXISTING ZONING: PROPOSED PROJECT AREA: PROPOSED TYPE OF CONSTRUCTION: PROPOSED OCCUPANCY: EXISTING TYPE OF CONSTRUCTION: EXISTING OCCUPANCY: JURISDICTION: COUNIY: RESULTS WAY CUPERTINO, GWFORNIA 95014 357-20-046 3T 19' 10.18" N 122' 03' 09.82" W NAD-83 P (ML) 935 SQ. FT. TYPE V-8 U NOT APPLICABLE NOT ACCPLICABLE CITY OF CUPERTINO SANTA CLARA PROJECT DESCRIPTION ATkT MOBILITY PROPCSES TO CONSTRUCT, OPERATE AND MAINTAIN AN UNMANNED WIRELESS COMMUNICATIONS FACILIlY. THIS FACILIIY WILL CONSIST OF THE FOLLOWING: • INSTALL A PROPOSED MONOPINE WITH (12) PROPOSED AT&T ANTENNAS WITHIN THE PROPOSED EQUIPMENT ENCLOSURE. • INSTALL (24) RUNS OF 7/8"0 COAXIAL CABIE AND (12) TMA'S. • INSTALL AT&T OUTDOOR E�UIPMENT CABINETS MOUNTED ON A CONCRETE PAD WITHIN A CMU WALL ENCLOSURE. • UNDERGROUND UTILITY RUNS FOR ELECTRICAL AND TELEPHONE. LEGAL DESCRI PTION BEING ALL OF PARCEL 3, AS SHOWN UPON THAT CERTAIN PARCEL MAP WHICH MAP WAS FILED FOR RECORD IN THE OFFICE OF THE RECORDER OF THE COUNTY OF SANTA CLARA, STATE OF CALIFORNIA ON APRIL 12, 1979 IN BOOK 439 OF MAPS AT PAGES 12 AND 13 AND BEING A PORTION OF THE LANDS DESCRIBED IN THAT CERTAIN DOCUMENT RECORDED OCT08ER 14, 1975 IN BOOK 8662 AT PAGE 46 IN THE OFFICE OF THE RECORDER OF SANTA CLARA COUNIY AND BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT THE SOUTHWESTERLY CORNER OF SAID PARCEL; THENCE ALONG THE WESTERLY LINE OF SAID PARCEL NORTH 00' 01' 00" WEST 241.44 FEET TO THE SOUTHWESTERLY CORNER OF THE LANDS OESCRIBEO IN SAID BOOK 8662 AT PAGE 46; THENCE ALONG THE WESTERLY LINE OF SAID LANDS NORTH 00' 00' 33� WEST 318.23 FEET; THENCE SOUTH 89' S6' 46" EAST 274.02 FEET TO THE EASTERLY LINE OF SAID LANDS; THENCE ALONG SAID LINE SOUTH 19' 06' 48' EAST 335.47 FEET TO THE NORTHEASTERLY CORNER OF SAID PARCEL; THENCE ALONG THE EASTERLY LINE OF SAID PARCEL SOUTH 19' 06' 48" EAST 293.23 FEET TO THE SOUTHEASTERLY CORNER OF SAID PARCEL; THENCE ALONG THE SOUTHERLY LINE OF SAID PARCEL NORTH 82' 24� 51" WEST 261.05 FEET; THENCE CONTINUING ALONG SAID LINE NORTH 89' S7' 24" WEST 220.99 FEET TO THE POINT OF BEGINNING. SHEET INDEX T-1 TITLE SHEET A-0 SITE PLAN A-1 ENLARGED SITE PLAN A-1.1 TREE REMOVAL PLAN A-2 NORTH & SOUTH ELEVATIONS A-3 EAST ELEVATION C-1 SITE SURVEY (FOR REFERENCE ONLY) APPLICABLE CODES ALL WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: CALIFORNIA BUILDING CODE, 2007 EDITION, BASED ON THE 2006 INTERNATIONAL BUILDING CODE CALIFORNIA FIRE CODE, 2007 EDITION, BASED ON THE 2006 INTERNATIONAL FIRE CODE, CALIFORNIA MECHANICAL CODE, 2007 EDITION, BASED ON THE 2006 UNIFORM MECHANICAL CODE CALIFORNIA PLUMBING CODE, 2007 EDITION, BASED ON THE 2006 UNIFORM PLUMBING CODE CALIFORNIA ELECTRICAL CODE, 2007 EDITION, BASED ON THE 2005 NATIONAL ELECTRIG4L CODE CALIFORNIA ENERGY CODE, 2007 EDITION. IN THE EVENT OF CONFLICT, THE MOST RESTRICTIVE CODE SHALL PREVAIL ACCESSIBILITY DISCLAIMER THIS PROJECT IS AN UNOCCUPIED WIRELESS TELECOMMUNICATIONS FACILITY IS EXEMPT FROM DISABLED ACCESS REQUIREMENTS. SCALE THE DRAWING SCALES SHOWN IN THIS SEf REPRESENT THE CORRECT SCALE ONLY WHEN THESE DRAWINGS ARE PRINTED IN A 24"X36" FORMAT. IF THIS DRAWING SEf IS NOT 24"X36�, THIS SET IS NOT TO SCALE. �J RA J�ffrep Rom� d� Assoctahs� Inc. Archit�cture � T�I�communicatione 3 Sa� Joaquln Plaza, Suits 155 N�wport B�ach, Calitomia 92660 Phone: 949 760-3929 Fax: 949 760-3931 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO ATBcT MOBILITf IS STRICTLY PROHIBITED. STAMP c ��.D AR�,� �` V Rq� �'r � yF C-020876 * fA �'� F EB. � Q SlqT Q�' CAU PREPARED FOR �, _ at&t 4420 Rosewood Drive Pleasanton, California 94588 APPROVALS R.F. ENGINEER DATE SITE ACQ. & ZONING DATE ERICSSON CM DATE AT&T CM DATE OWNER APPROVAL DATE PROJECT NAME NOVEMBER DRIVE PROJECT NUMBER CN3242—A RESULTS WAY CUPERTINO, CALIFORNIA 95014 SANTA CLARA COUNIY DRAWING DATES 02/10/09 PRELIMINARY ZD REVIEW (P1) 06/08/09 DESIGN CHANGE (P2) 07/02/09 FINAL ZD'S (P3) 01/26/10 SITE RELOCATION (P4) 05/10/10 1009: ZD'S (P5) 05/21/10 CLIENT COMMENTS (P6) O6/10/10 CLIENT COMMENTS (P7) OS/i6/10 PLANNING COMMENTS (P8) OS/23/10 CLIENT COMMENTS (P9) OS/31/10 REVISED ANTENNA COUNT (P1 - --- ---__- RFDS REVISION LEVEL 1.6 SHEET TITLE TITLE SHEET T-1 � M 0 0 w � � Z U W � 0 a Q � � SITE PLAN KEYNOTES 1 PROPOSED ATdcT ANTENNAS MOUNTED ON A PROPOSED MONOPINE WITHIN A PROPOSED ATdcT EQUIPMENT ENCLOSURE; SEE SHEEf A-1. 2 PROPOSED AT&T 22'-0� X 42'-6" LEASE AREA WITH OUTDOOR EQUIPMENT WITHIN A 6'-0" HIGH CMU RETAINING WALL ENCLOSURE TO MATCH EXISTING; SEE SHEET A-1. 3 EXISTING UTILITY POLE MOUNTED TRANSFORMER AND PROPOSED AT&T POWER SOURCE. 4 EXISTING UTILITY POLE dc PROPOSED ATdcT TELCO POC. 5 PROPOSED 5�-0" WIDE AT&T UNDERGROUND POWER dc TELCO CONDUIT ROUTE. DISTANCE 318'-0"t. TELCO CONDUIT SIZE TO BE 4 DIA. SCH. 40 PVC. POWER CONDUIT SIZE TO 8E SPECIFIED BY SERVING UTILITY COMPANY; SEE DETAIL 2/A-1. 6 PROPOSEO 12'-0" WIDE AT&T ACCESS ROUTE TO SITE. TO BE CHANGED AFTER DEVELOPMENT OF SITE. ___ .._._... __. _....�.._ ._._- V � 20t0-03 ...._.__._.... VxC - 2010-Oy' i �^ Z01�� �� . _ � ... "7 --��-- � �': �;:.:C'�t FYA :4 x!R exYY yt� :.�r iZr�+�� � ,�j GO"J�E'�.,t��"k'S' ��� /O �A 6�AE3�l�o�a F.. ;ap 3 �:.s,;. lh:s � ����Sw$g!3'� Cua� !�i �;cc 7 FUTURE DEVELOPMENT ASPHALT PAVED PARKING. "''"� R �'`^ ��� � (UNDER SEPARATE DEVELOPMENT). , � = '`� �'i%' ~ � � ,� � l / -- % _,�- �, ` ; �- -. J, � .� ., � � - - ,,,. .,,,.� /. ;� 8 FUTURE DEVELOPMENT BUILDINGS. � ',' Y � 1� ,, �� s4 cs (UNDER SEPARATE PERMIT). _ . „/ Y ��" �, '� ,- ;,� � � i i �_/'-/ �`' ; A ,� ; � . J �-�- �� : - ` t � i3: n ' "'�,% ~� }�. ;� � ; .-- 9 EXISTING BUILDINGS ON PROPERTY. �, �,J.J . $-'� / BIO wn�E � -''"�.r � I � � �`,� „ � "' ' � / ��) nt � � . '� ,.-� �.-,-- � �.... , i- ¢ ,� �� ,, 70 D(ISTING PROPERiY LINE. , � ' ;-'' ;:��-{ .:.� a,, / � � �; ,.s'; r ��.�' 4 ,;` � �t, / r ,,. ' ..^:. . , � i ''/ . ,-,.. r.. i� � . "%! � '' �� �. 1l, � / \� �r� i�'..- � ' �� '`� \\., � �� �� .:�,. 11 FUTURE DEVELOPMENT ACCESS DRIVEWAY AND FUTURE " '� '� � FtO � I'C � �" ""i ��. '"'�� � �� � LENGTH A3 � 20' KATHREIN 742-264 70 10 7 B A4 20' KATHREIN 742-264 70 10 7 B 81 260' KATHREIN 742-264 70 10 7 82 NORTH 260' KATHREIN 742-264 70 10 7 8 83 WEST 260' KATHREIN 742-264 70 10 7 8 84 260' KATHREIN 742-264 70 10 7 8 C1 140' KATHREIN 742-264 70 10 7 8 C2 SOUTH 140' KATHREIN 742-264 70 10 7 8 C3 WEST 140' KATHREIN 742-264 70 10 7 8 C4 140' KATHREIN 742-264 70 10 7 8 ANTENNA COAXIAL CABLE SCHEDULE 2 1. CONTRACTOR TO PROVIDE ALL LABOR TO INSTALL 30 RUNS OF COAX, 12 TMA'S AND 12 ANTENNAS. 2. ERICSSON TO PROVIDE ALL COAX, CONNECTORS, ANCILLARY EQUIPMENT (INCLUDING WEATHER STRIPPING, GROUND KITS, EfC.). 3. CONTRACTOR TO COLOR CODE ALL COAX. COLORED BANDS OF TAPE ON COAX IDENTIFY SECTOR, FREQUENCY, TECHNOLOGY, AND TRANSMIT GROUP AS FOLIOWS: SECTOR "A" TX 1/RX 1 TX 3 TX 2/RX 2 TX 4 TX 5 TX 6 GSM 1900 z BROWN 2BRWN/1RED 2 ORANGE 20RG/1RED 2BRWN/2RED 20RG/2RED TX 1/RX 1 TX 3 TX 2/RX 2 TX 4 TX 5 TX 6 GSM 850 3 BROWN 38RWN/1RED 3 ORANGE 30RG/1RED 3BRWN/2RED 30RG/2RED TX 1/RX i TX 2/RX 2 UMTS 1900 4 BROWN 4 ORANGE TX 1/RX 1 TX 2/RX 2 UMTS 850 5 BROWN 5 ORANGE 12'-0 WIDE ACCESS ROUTE. `= �% � '� _,�,.�' ` % � � � -- , , � .--'` �-��\F�C .,. , � \ i � �- � � :. .. � � � � I�1�1G p• n, :a ` � '� �` ` - � ;:.. �` : . r i � --- �!Q{� _ h � .� / ` � N �� .,� \�\\,'`,-� ...� /' // �. /'�/^`�. ' ,- {� 1 / t , y,�.;�r _ '" " �i � � „/��/ , . i� ' .i' / � / / � �� J - " � � e � _ ��•,� /r � � �-~' 91 �LE ,f „�%'. �'' � ������ � : Q�J I3��� � /,�//��� �'---� SECTOR "B" `,�„> � �t ,�, s-' / � )�- / , X, •_._._..._..-�..8 J � �!�" ,//I 7/ ' TX 1�RX 1 TX 3 TX 2�RX 2 TX 4 TX 5 TX 6 -� - ' / ` ' / � � ✓ � ---' + � / � ✓ C i � o _�*=�'�+/ �, / 1r ,' j -_ � ! ,;/ ; � � ,,,.�-� / / ` , � , �V � � � �� � �� f � 2 YELLO EL/ R 2 BLUE 28LUE/1 RED 2YEL/2RED 2BLUE/2RED � I � SM 900 2Y 1 ED r r--~ �= _ , i �- �.i � ` --_ . +- �,. . . : " � \ � ,;� � i � �� / ' '' \ . 1 :' .� . i I , � .' ��..� �' .� ' � �i � / . � _ � � � �ii ; �� � ; s�?� ,� E � 1/RX TX 2/RX 4 TX TX 6 ! �/ ;; `�,.- �Y / � } � ,� •' � `:`,�� -�. . - � -�f �` � ' J 3 YELLOW 3YEL 1 RED 3 BLUE 2 38 E 1 RED 3YEL RED 3BLUE 2RED , % f ,,r . 6 t �*,:�---- i-� �- .� - � � � ..�-�._ � . -`� r {y �! / GSM 850 TX 1 /RX 1 TX 2/RX 2 J , �,. .- - , i -- �-�. - �� \ � ' � E g 4 a j - �% � , ... - _: ,-�. .✓ l � � �� �,. ^ � � ,.. �. , , j . � .. �� � ;� � / / U MTS 1900 1 - �� -^.,.,-- i �� � .', y- �, �� �� \. ,, . _ ' `, � / / "'' 4 YELLOW 4 BLUE t'. � � "' - � / . . � � J� _ : y �CP �3�:�. l - ,�;�:..- _'--^ „y: •' � � .- � -� �� � � \ ,.._. � . � : � , .. , �. J , ; ,.. , .. �ic �6ioswn�E ,.-� r" . ;, -- w � � � , �. --�, TX 1 /RX 1 TX 2/RX 2 � , � / �,,�,,: '" ,- ,X, " �-' r � �,;. � l% \ ^_�t ,� i X� � �� {� UMTS 850 .... � _ � ��� i �T�'�') ! �,,,.�" � ,,, � ___ .: 1 �`` � 33 5�' �Ix�� ,/ ---�i . 5 YELLOW 5 BLUE �� �- ,..- . � .� .. ... -;;;� , i .-- ,,,..- '_ ' , � ` ;s .,`...... , ' �l / i-''�' - /+ �,.. �-- , � f � s i �, i _ ._- %r _� �, . �� �� � ,::- � f �: � , �J , „ , . :�+;` , � � .. � , � - - 1. �..�----- , �.� ; � . ,, ,,r , . ,� - _ , � � ; � ,. _ __ l .. � � . ..-�,.��.:'' . � i ��/ �' "i /-"'. � ' '�$R �i �� . �, �`j ,� ,�'�iBTOSW ,� ( - � � .. �� � ,�� , . � '���. !' '' / �- . .. .. � _= ' / � � i \ 3 '? ��'hiP�355.5 ( T / ,✓ i � ..' � ` `i � ,- . � - ` .-- i i _ . ,� ,,- :,. �.�;� i � . •. .....,- � � �__..._._.--- " x' � � _ -� j ,� �_: , - �, r _. �� .� r . �! ,� j: � -'�- � y- , , -- � •� � � � ' '� � �- ' , L" - % � � � � � " � - - - - '� i � SECTOR "C" ; � �.r . � , L �,..- , . , . � . ,:- B. \\\� � ` % ! , � . / �_.. - �,. �. - ( ; _ >` - .- 6 ..., �,. � �.- �. _ s ���� / , f ., , _ �- ,, ; � , .�-- � .-- i 5 , r-- . / i �' T � � i .-- _ . L � i --, .. -- ' w � / �� � i � � � _ _ `` ` 1Y _ � ' � ;-i i , � ` +- �- � ^ I � , !,! \\ , j TX 1 �RX 1 TX 3 TX 2�RX 2 TX 4 TX 5 TX 6 ,. }�"" � � � i __�: ^,". . > , _> �.9� i r `� p'.-„T�_,_� i 1� � j , GSM 1900 ,%....Y / � /f- � � _ �\ � � _._ . . __._...__. ..._.._._ _ y�, � -1 --- D 2 D ED , _ _ �� � -' z'S'J� �.C' � :�.. ,. �.. \ „ , i .. �- - ,'� �:_. '� , - �..--; � ' ' '-- 1 --� ,� .._ _ l `,,.• 1 , , -` v' �j � w �i � � T ! �. � j 2 VIOLET 2VI0/1 RED 2 WHITE 2WHT/1 RE - - VIO/2RE - - 2WHT/2R . _ � .,- � � „ .._ _ .__.._ _ ,�- `� ..-.. �_ ..-��r' ' x , ' , , J`, V ., ,. .. . . ,., �,; �; ..�;;�-- ;'" � ., .. .r .= �'" I I : , � - - , , _ � .: r ..._ .._� f ', :: � . ; TX 1 RX 1 TX 3 TX 2 RX 2 TX 4 TX 5 TX 6 %' ��` r' �. �" �: �; t pP ,, �' ,�,> taa. > I ' I �. � ` I `; / / I , ... / � . ,., ,, `,� `', , . k ' . , i � , , ',, v n �.,u°'G j,- _., ,� . � � , T '1 �J� i i i ; , ; � , : I _ .., � ...� . i � I GSM 850 32q,� , , 3 ; �., � ��; g .`0 , - �,. /�� � ' �•�'' " ' y 3 VIOLET 3V10/1RED 3 WHITE 3WHT/1RED 3VI0/2RED 3WHT/2RED �. � , . z .�,. ,�p ' ..{ \ � „ , Y ,- ,.-� �.. , J ;--� _.. i . ( , },.. `•O � '�� ,, ^� ' . ' ,/�, j/ ,A/ 'r7}�� 6 ---•�' �F �� TX 1/RX 1 TX 2/RX 2 : .,� 4 � �r�.� . �`. �y � ,• l '� '•, � ��� �. �; �' �7 �,�', ., ,...k.iC' - / , � ��� ,�/ sre..im'. •--��.-33 � _ ....� r ' , . � � � ... ..._. UMTS 1900 ( - .. � '�, •,,; , ,, '. � . ',, ,�;. '`, � ; I , .,�--- , s�:e � -- � i , i , '- -- � � � - � , , ,�I 10 , , ' �', _- �� ' i ' �:; '--�� i ; � � i � i j I � ( i � -;,- �. , , . , , �, � � t-. , , , , 4 , t�� , �,i ; � /� �� .� r �� � t r� l- x x X �.. �/ %� �., ` _:, ,, , ,, , : v' `, , . I , : � '�, '. •� , , . ! /�� _ s� " F ._ � _ . _.-- - - =`f „ 'I -- --- T4 VI �R� 1 TX %R i, .--c � � , ; - : ��.- . , j .. -• ', � , ', � / S�' - -- -- _ _ - - - ! r- - - -- --..._ � �'e= UMTS 850 �. � ; ��- , . , , , ; �.,. , !, I , , . -� : /' , �- ,_,'� - - - - - ��CII41ITS 5 VIOLET 5 WHITE , , '' � . ' � .- � / �� __ ,. ,. ', � .� , / , ', .��. , , �. , �� � � , - . k _ �- �i . - ---s_ ;, . 1- � ' .�� . - - � , e , , �„ �, t p �i : ._-. � - - ,,'� , `, , ,, `, r ,, �, , I "+- �=��€ �`�8 ,�av � ` ,�,� � � . , �+ -. 4� � g i ' ` � I "r . � ' -�'-'�,� TC . II , � �, ::-�' '� , . ,"� - - - - - -- ,� -,. ,` , , ,.a. � `` �- _ 7 • • = � i . ,;� =' • �:. .�.ys=' �� , , . � r' 1 ' �; , ,..; . �; , /; 3 � _ _..�� � �. � y ,,, ,, y , .. , � g a �: ,^ , , , / 51 �'' , ,'`: i � F ,, -:. :,� ; . � , , ,; � : ���_ - � � i t ��-'' ; X : - � -- ! I ��` . I `'.: ' '; ', : , ', '', ' , ! ' I � ! � ; , 4. WHEN ANTENNA UNES ARE DIPLEXEO, THE COLOR CODE OF THE HIGHEST FREQUENCY � + � ,,-' r�"' l l� I I _ ! �'" ��u� � P I�� 51 APN: 357-20-041 �' PREVAILS (I.E. UMTS DIPLEXED WITH TDMA SHOULD HAVE COLOR 4 BANDS). ' \ , `, y ` ��l-�- �- �- *-�- , ; � - � { _......- j ! I' : A ZON NG P(M ) 6 ^ �ss ` .,, :,>, I � � i ZONING: P(ML) I I:� '' � f f Y �� I I_ ' � i ' •' P 5 ISHED BY ERICSSON INC. AND . ALL ANTENNAS AND ANTENNA CABLE SHALL BE FURN � � � BUILDING 4 g INSTALLEO BY ANTENNA INSTALLATION CONTRACTOR. BIOSWALE ''j �., �.-.: � I � � O I ' ..' � lTVPI � ���._ �_.. ��---'� "� ' ' .. . .. BIOSWA�E (T►' f (i a �, � �'� , V „ ' ���� �' � ! � �(� PROPERII('.11NE j �� i � i � I � i l ' � 30 � � I _ � �..�. � J_-_ X' � 1�,; � II: I I "� i I II �� ��,, II . . II a� ��� r` IM PERIAL AV ENUE �{-- - t� �� � \� S ITE P LAN _� t �� O -, _� � � BUILDING 5 ( - I 6. PRIOR TO PLACEMENT OF ANTENNA POLE MOUNTS, THE CONTRACTOR SHALL VERIFY THAT I � I � ' E1�V BUILDING C 1 '�'� 2 ' �! � EX FFE 343 8 � i� , �, � . � THE AZIMUTH AND DIMENSIONS SHOWN ON THE PLANS MATCH ACTUAL FIELD CONDITIONS. C.1:__ ;: --_ , /�; 3 ` j�' ALLOWABLE TOLERANCE: HORIZONTAL AUGNMENT = f5'; VERTICAL ALIGNMENT = f1'. «� � I_ � � FFE 336 3 1 ! ,� � � i , � ., I , � , PAD 335 � � � �-+-� -�-� I � I � � � i ' 7. ANTENNA INSTALLATION CONTRACTOR SHALL PROVIDE ALL CONDUIT, CABLE TRAY, i' f � � I I I !�- �� ExiSPNG LOT LINE ,; J I � � I, GROUNDS, EfC. FOR COMPLETE INSTALlATION OF ANTENNAS AND CABLES SHOWN AND ' '' � , � I'i� ` . _ ;. - � - -- - - INT N AS REQUIRED FOR A COMPLETE OPERATING SYSTEM IN ACCORDANCE WITH w � � i '� 5���-2� I � i� �� ERICSSON INC STANDARDS __ ( � I- ' ..�y.. �'..._ . __-___.. 336 .. �'_; ;i �_�� : i - __ � - ��.i: � /i .� ,. , , . , / /� /� , f '. . . ' r E DED j ; , ; I � I �.:_�?' � � t�� /, i '�``' -"- --=------.� � _-• _ . � " i 'i j ' ' ' ' �� ' i , ; i � ; f `� �;' 8. IN NO CASE SHALL THERE BE ANY MORE THAN TWO (2) 90' TURNS (OR EQUNALENT) IN ` ' � 1 ' }�`� '-- - ` ' � � ' - LIMITS " _ - �' : "�'' +. -�+, ! ', ANY CONTINUOUS LENGTH OF CONDUIT BETWEEN PULL BOXES OR SIMILAR FEATURES. - •� - �+ -- Y" - :-"-• �- �T � .. --� I � .. . � f � ._ i� . �� :. � i'--�:_� w r _ . � . _ . ,��_: T•r•r....�.�. ,�n�...r � . ��... s ,.�.,_ + �„�,�� � 4 �,j�'C i �, � j !: ���ti� 3 � ' � � * � ��,.. :r' � ' i` �� ^? f i � s `i i . � . � / i , r _ 9 ; � r ;, r:_ ;; �. \, ,,_ ,,. I , I �`f; ,t 1 `'/_ � �L. a i : ' ' I : ; ! ! LI I '. ' ; : ; i ; ; 7 ; : ;`; I ; : ' ' , . , _ - 3� 0`•.� � � i ; ; � 3 I, - --�i 9. ANTENNA CONOUIT SHALL ONLY INCLUDE FACTORY-MADE LARGE RADIUS W P AT � , i , , ; � . - � ;''� I , J L� �;��, � i ,i, �.. � � . �. ' , �,,. � � _' S EE S ��I , �� C � � � '" / I ,` - ALL CHANGES IN DIRECTION. SWEEP RADIUS SHALL BE 18" MINIMUM ABOVE GROUND �r - - - ;- -� - ' - r � - ��-%�-�-�`' L - - -����I `' PROPOSED/LOT LINE�� ' ; EXISTING',LOT �INE AND 36 " MINIMUM BELOW GROUND. �,,.i i � : ,� �., ,,.,; i l e i � ; , i i � i iI i i i i i � i i I i i i � � i �: i i � �i � �, ', � �i �' ;� � ! i i' i 'i �' ;� ;' ,� i; i� ± � i CONDUIT SHALL BE 3"0 MINIMUM. ALL UNDERGROUND CONDUIT SHALL BE SCHEDULE ,: � '' a � � ' , ; ' ; 1._._.� ! ' ' ' � 10. - ' � '� ' � _ �._ ! .� ( -- - --- -- __-_ --- _ �. _...._____ i- __ -_-_..� - - _.__...� . _.... -- _ ___ - � ,`_-.-,,,� ._„_,_ _..__.._.._.__�..___�__._.._..._. _,, .,__ _______�. _ 40 PVC. ALL EXPOSED CONDUIT ABOVE GRADE LEVEL SHALL BE IMC OR RIGID -"'""'" " "'� ' "�' -�"` '"' � � ILOING OR ON A ROOF S --�--_ _ _._... _ � , �._ . T_ HALL �--. - A . . ,-- ... _. :... - _.._ , ,..� -. , „_, .:_ .. �'._-z ._. ._. �..�.._=�.._��_.... - _.._. _---�--- -- ,._,.;,: � �,. _.:: � _._ BE EMT OR W STABILIZED PAINTED SCHEDULE 80 PVC. t , . . � :.. ; i �� ' r� s � . � ` �� 1 ..i .�'�.�� , �� _ �r - - �. . .;� " � � �' � f � ; f ' "' { ; �^'-=- -; [ '-` �l � /' �, 11. IN HIGH TRAFFIC AREAS OR WHERE SUSCEPTIBLE TO DAMAGE CONTRACTOR SHALL � � � �~ ' �` n_�, . J � �.._.__.. .�---� 3 ,; ,;`� C � ` '� ���`` _� I` f `t� � PROVIDE FORMED GRIP STRUT COVER OVER COfU(IAL CAB�E ROUTES. WHERE CABLE IS �_ � (: __ - �, . , ( � ; ` � � RUN ON THE WALL, ATTACH UNISTRUT TO WALL AND COVER WITH 14 GA. GALVANIZED FORMED SHEEf METAL COVER OR MATERIAL AS DIRECTED BY ERICSSON INC. " I I 6 CONSTRUCTION MANAGER. I � m NOTES 12. VERIFY ROUTE AND IENGTH OF CABLE PRIOR TO CUTTING. ADJUST INDICATED ROUTE t � AS REQUIRED TO CLEAR (E) EOUIPMENT AT FACILITIES. N p 13. MAXIMUM LENGTH OF 7/8" COAX CABLE SHALL BE 140'-0". MAXIMUM LENGTH OF rn 1. FUTURE DEVELOPMENT SHOWN TO CLARIFY ACCESS ROUTE p I p 70 1-1/4" COAX CABLE SHALL 8E 190'-0". MAXIMUM LENGTH OF 1-5/8" COAX CABLE AND UTILITY ROUTING FOR PROPOSED AT&T SITE. ALL - - SHALL BE 235'-0". _ •� DEVELOPMENTS IN THIS DRAWING OTHER THAN REFFERING TO AT&T IS UNDER SEPARATE PERMIT 14. VERIFY MODEL NUMBERS OF ANTENNAS WITH ERICSSON INC. SERVICES. 5 2. FINISH ELEVATION GRADES BASED OFF OF FUTURE SITE � 15. THE CONTRACTOR SHALL PROVIDE TESTING OF ANTENNAS AND SHALI PROVIDE DOCUMENTATION TO THE ERICSSON INC. PROJECT MANAGER. 3 4 DEVELOPMENTS BY DEVELOPER. _ 16. GENERAL CONTRACTOR TO VERIFY ALL TORQUE TOLERANCES PER THE MANUFACTURERS I SPECIFICATIONS AND RECOMMENDATIONS. I SCALE: � 3 GENERAL ANTENNA & CABLE NOTES � 1 "=60' 0 30' 60' �.J RA Jsffrsy Rom� � Asaociaha, Inc. Archit�cturo � Tdscommunicationa 3 San Joaquin Plaza, Sutfe 155 Nswport Bwch, Califomfa 92660 Phons: 949 760-3929 Fax: 949 760-3931 PROPRIETARY INFOR�IATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION OOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO ATBcT M081LITY IS STRICTLY PROHIBITED. STAMP c ��D ARCy� J '1 Rq� �i � * C-020876 * f �� F EB. 2 �' SlqT OF CA1.�F��� PREPARED FOR at&t 4420 Rosewood Drive Pleasanton, California 94588 APPROVALS R.F. ENGINEER DATE 51TE ACQ. & ZONING DATE ---- _ -- ERICSSON CM DATE AT&T CM DATE OWNER APPROVAL DATE PROJECT NAME NOVEMBER DRIVE PROJECT NUMBER CN3242-A RESULTS WAY CUPERTINO, CAL1FORNIA 95014 SANTA CLARA COUNN DRAWING DATES 02/10/09 PRELIMINARY ZD REVIEW (P1) O6/08/09 DESIGN CHANGE (P2) 07/02/09 FINAL ZD'S (P3) 01/26/10 SITE RELOCATION (P4) 05/10/10 1009: ZD'S (P5) 05/21/10 CUENT COMMENTS (P6) O6/10/10 CLIENT COMMENTS (P7) OB/16/10 PLANNING COMMENTS (P8) I OS/23/10 CLIENT COMMENTS (P9) , 08/31/10 REVISED ANTENNA COUNT (P10)'I RFDS REVISION LEVEL 1.6 � SHEET TITLE SITE PLAN � � M n O 0 � � � Z U w � O a a � ENLARGED SITE PLAN KEYNOTES , �, � I 17 �1 � , „ O1 PROPOSED AT&T ANTENNAS MOUNTED ON A PROP05ED MONOPINE. , �" � ANTENNAS TO HAVE NEEDLE COVERS OVER PROPOSED ANTENNAS; I i i 22 0". S E E D E f A I L 3/ A— 1. I `� ATdcT LEASE AREA 2 PROPOSED (3)_ ATdcT OUTDOOR EOUIPMENT CABINETS MOUNTED Z� ON A CONCRETE PAD. , - �i;; �i; ;q; 3 FUTURE (4) AT&T EQUIPMENT CABINETS. 33Z.O.Of � F.G, 332.2 t ,� 4 PROPOSED ATdcT GPS MOUNTED TO EQUIPMENT CABINEf. I F�• � � ;�, � 0 5 PROPOSED AT&T HORIZONTAL COAXIAL CABLE RUN MOUNTED TO WALL 18 20 a � N / � 2 � -9 � 6 PROPOSED METER/MAIN, EMERSON LOAD CENTER, AND I — — — � WEATHERPROOF GFCI MOUNTED ONTO CMU WALL WITH UNISTRUT. - 1 332.67f 6A PROPOSED TELCO FIBER MUX CABINET AND ALARM CABINETS MOUNTED 19 4 ,_4. ,;",; F.S. TO CMU WALL WITH UNISTRUT. 7 PROPOSED TECH LIGHT MOUNTED ON PROPOSED �'�� H—FRAME UTILIIY RACK. � � � 332.83t � � 8 PROPOSED WATERPROOF SWITCH FOR TECH LIGHT TO BE � � ��' MOUNTED TO CMU WALL F.S. ' __ ,;� �,'� �,�� —� .;�: 6 ' '�"' '��' --- 9 PROPOSED 6'-0" HIGH CMU RETAINING WALL, WITH I I ,,� ,,�, �, , , , , ,,�, CLADDING TO MATCH FUTURE BUILDINGS IN ' ,,, � ,;� � � I COLOR AND STYLE. � I � -' I� `�� 10 PROPOSED 4'-0" WIDE SINGLE METAL TUBE � ACCESS GATE. � � �� ' ' � � � I I ; � �' I i � _ 11 PROPOSED 5-0" WIDE AT&T UNDERGROUND POWER �,�; � I � dc TELCO CONDUIT ROUTE. DISTANCE 318�-0't. �-- � TELCO CONOUIT SIZE TO BE 4" DIA. SCH. 40 PVC. _ J POWER CONDUIT SIZE TO BE SPECIFIED BY SERVING 7 UTILITY COMPANY; SEE DEfNL 2/A-1 FOR TYP. TRENCH DEfAII. —� � � � I 12 EXISTING CONCRETE CURB. I , f I I � I I 13 EXISTING ASPHALT PAVED PARKING. I / I 14 EXISTING TOE OF SLOPE. I I I � / /� � — — � ' 15 EXISTING TOP OF SLOPE. I , r 16 EXISTING TREES AND SHRUBS TO BE REMOVED. � 8 � 17 EXISTING TREES AND BUSHES, PROTECT IN PLACE. �� , , � �, ToR „ � , 18 EXISTING BLOCK WALL SEC ( I , 26 19 EXISTING PROPERTY LINE. � � ' I �I I 20 PROPOSED ATdcT ACCESS STAIR ANO WALKWAY. , � I , I � 10 � I I 21 PROPOSED 4'-0" HIGH REfAINING WALL. i� I I ' I � — 1 33 .25t _ _ � NOTES: � 'F.S. f? � I �� �I � , 1. FUTURE DEVELOPMENT SHOWN TO CLARIFY ACCESS ROUTE AND UTILITY ROUTING FOR PROPOSED AT&T SITE. ALL DEVELOPMENTS IN THIS DRAWING OTHER THAN REFFERING TO AT&T IS UNDER SEPARATE PERMIT. 2. FINISH ELEVATION GRADES BASED OFF OF FUTURE SITE DEVELOPMENTS BY DEVELOPER. ENLARGED SITE PLAN � � �� ��� � I I , , ,, , , ,, , � ,, � , � �, � ,, � � � � �� � I , , 14 ��' � -- I I I ^� � ' � ��� ;", � '%� � � ,� � �; 16 I I / I ' "� ; � � \ 1'-6 � � � \ ., �, � � � ;; � ' �32.83 i 332.67 I F.S. ' F.S. � � 331.67t� � '' '%� ��, F.G. 9 ._ 0 . " �o'��o' 2'—s° � I NOTE: ANTENNAS AND SUPPORT ARMS TO BE PAINTED GREEN TO MATCH MONOPINE NEEDLES. I � I I I I I I I I I ) I , � 327.10t� j � I / I / / I / / i � 6A ---�� I� I I I I I � I � � / I � I � � � � � � � 3 Q MONOPOLE FOUNDATION. TMA — T(PICAL (2) PEF SECTOR. ATdcT PANEL ANTENNAS TYPICAL (4) PER SECTO TWO STACKED RAD CEN' 6 ANTENNAS O RAD CE 6 ANTENNAS O RAD CENTER 58' AGL. „ SECTO 26�� ANTEN NA P LAN VI EW � �O ry �t/ � ��,�'� N 1 � � �'' 5�,�: � 3 1/4"=1'-0" 0 2' 4' FINISH GRADE PATCH (E) SURFACE TO MATCH (E) ADJACENT SURFACE REMOVED FOR TRENCH WARNING TAPE SAND BACKFILL (90x SCREENEO) TAMP TO 95X COMPACTION IN 8' LIfTS, EXCEPT FOR ALL PAVED AREAS USE 2—SACK SLURRY ENCASEMENT. 4'0 SCHEDULE 40 PVC CONDUIT FOR TELCO \ \\� � �2 SOLID BARE GROUND � \ /\��\��\��\��\�� � ��� �\� �� i\� POWER FEEDER OR UTILITY SERVICE. SIZE PER SERVING UTILITY COMPANY REQUIREM.ENTS. NOTES: t. ALL DIMENSIONS SHOWN ARE MINIMUM CLEAR. 2. ELECTRICAL CONTRACTOR TO INCLUDE REMOVAL OF SPOILS. UTILITY TRENCH DETAIL U-Z�iO--t3� -- • - � pcc-zao-oy- i I'���6 e'�E.�+1��i��.: �^'�... �.��».�� -5..�....-.a d �a:sa, :+a�:++� I � 327.10t � T.C. I ----� � \ �o � � � a�y y�,+ ^�,. t � '*e �� r'tWr � ," >'.�'�.i".^8 i_ 1 1 r t O �i� 0: r .� ....�.>'�: 1�.b.. ttDb? 13 ��� i��'���� • �i��� ii 1t@� SCALE: NONE , , „ SCALE: � 1 3/8"=1'-0" 0 1' 2' 3' J RA Jsffrs�r Rome d� Auoctates, Inc. Architecfure k Telscommunicallona 3 San Joaqufn Ploza, Suft� 155 Nswport Beach, Calffomlo 92660 Phonr. (949) 760-3929 Fax: (949) 760-3931 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET Of CONSTRUCTION DOCUMENTS IS PROPRIEfARY 8Y NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO ATBcT MOBILITY IS STRICTLY PROHIBITED. STAMP c � N �D ARGy� J 'l Rq� �r �� yt C-020876 * f, ��: s F £B.2�' L ��� qr f �' CA�� PREPARED FOR at&t 4420 Rosewood Drive Pleasanton, California 94588 APPROVALS R.F. ENGINEER DATE SITE ACQ. dc ZONING DATE FRICSSON CM DATF ATdcT CM DATE OWNER APPROVAL DATE PROJECT NAME NOVEMBER DRIVE PROJECT NUMBER CN3242-A RESULTS WAY CUPERTINO, CALIFORNIA 95014 SANTA CLARA COUNTY DRAWING DATES 02/10/09 PRELIMINARY ZD REVIEW (P1) O6/OB/09 DESIGN CHANGE (P2) 07/02/09 FINAL ZD'S (P3) 01/26/10 SITE RELOCATION (P4) os/io/�o �oox z�'s (PS) 05/21/10 CLIENT COMMENTS (P6) O6/10/10 CLIENT COMMENTS (P7) 08/16/10 PLANNING COMMENTS (P8) OB/23/10 CLIENT COMMENTS (P9) OB/31/10 REVISED ANTENNA COUNT (P1 RFDS REVISION LEVEL t.6 SHEET TITLE ENLARGED SITE PLAN A-1 � � 0 m � � � Z U W � 0 a a � �0` � 18' ENLARGED SITE PLAN KEYNOTES < < 1 EXISTING 6" 0 REDWOOD "SEQUOIA SEMPERVIRENS" I � TO BE REMOVED. � tA EXISTING BUSHES TO BE REMOVED. 2 EXISTING TREES AND BUSHES, PROTECT IN PLACE. 3 EXISTING CONCRETE CURB. - 4 EXISTING ASPHALT PAVED PARKING. 5 EXISTING TOE OF SLOPE. 6 EXISTING TOP OF SLOPE. 7 IXISTING BLOCK WALI. 8 EXISTING PROPERTY LINE. _ _____._u_ ._ _�._U- 201 p-p 3 ._�____ - QcC.- 20 l o- o�{- ..r . f_ ;. _�� _�2.- 20�0-3 � 4.'�kr x i:ue : is!kirf� �a.'�s�f'►�':��r,? �`��g����dS.��l11, (- � �^-(O {lal� Sl�dldtlll'� C�sc A1uuu TREE REMOVAL PLAN �� I' �� � ����'�, I � y / . � � I i �fw� 1 i � � �, � � �' i �� , � � ii; %'�� � / � , { � I � I � ���� , , � ,. (.. ,,- �,._ � � ,,� { � t, , ;', i I ' I, %, "i , : � ,' �- I , � � � � 14'-8"' AT&T LEASE AREA /: ,{ � ' ' � -� � � 1 — �- � — - � I ' � I � I � I � , I I 1 � . � � � � I I � ' I O � : � � I ' � I , I i I � I � � � � � I O � � �, � I � I I � � � " � � I . I / O � � � � � �� � � � � � � � � i I I — — — — — — — — — - � �, � � , � �� ��, , ,� � � 1 '- �a �I � '��; i � j, � �� � � � ;, ;,;. � ,';� � � � ; , K � i, � . `� , /; , ; , ? , � , ,, � � � � / ' s � ' ,/ ' / '/ / I �i � � :. � /�' / ���. I � 4 � , , „ S��E: � 1 ��4-=,�—�M 0 2� 4� �J RA Jeifrey Rome �c Aaaoctatsa. Inc. Architscture � Tslecommunlcallona 3 San Joaqufn Plaza, Suite 155 Newport Beach, Coliiomfa 92660 Phonr. (949) 760-3929 Fax: (949) 760-3931 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY 8Y NATURE. ANY USE OR DISC�OSURE OTHER THAN THAT WHICH RELATES TO ATBcT MOBILITY IS STRICTLY PROHIBITED. STAMP c �NSED ARCy� J � Rq� �i� �� * C-020876 * fA �� s F EB. 2��" �\Q qr F OF CAUF�� PREPARED FOR at&t 4420 Rosewaod Drive Pleasanton, California 94588 APPROVALS I R.F. ENGINEER DATE SITE ACp. dc ZONING DATE Fairecnti �u neT� AT&T CM DATE OWNER APPROVAL DATE PROJECT NAME NOVEMBER DRIVE PROJECT NUMBER CN3242-A RESULTS WAY CUPERTINO, CALIFORNIA 95014 SANTA CLARA COUNTY DRAWING DATES 02/10/09 PRELIMINARY ZD REVIEW (P1 O6/08/09 DESIGN CHANGE (P2) 07/02/09 FINAL ZD'S (P3) 01/26/10 SITE RELOCATION (P4) 05/10/10 100X ZD�3 (PS) 05/21/10 CLIENT COMMENTS (P6) O6/10/10 CLIENT COMMENTS (P7) 08/16/10 PLANNING COMMENTS (P8) 08/23/10 CLIENT COMMENTS (P9) 08/31/10 REVISED ANTENNA COUNT (P RFDS REVISION IEVEL 1.6 SHEET TITLE TREE REMOVAL PLAN A-1.1 M O O� W m � Z H U w � O a < � ELEVATION KEYNOTES O 1 PROPOSED ATdcT (6) (2 ANTENNAS PER SECTOR, 3 SECTORS) 5 EXISTING BUIIDING. MOUNTED ON A PRdP MONOPINE. ANTENNA TO HAVE PINE NEEOIES COVERS OVER EACH ANTENNA. ( ) 6 EXISTING LANDSCAPING. PROTECT IN PLACE. � MOUN�ED ON A PR MONOPINE RANTENNA 0 HAVE RS) PINE NEEOLES COVERS OVER EACH ANTENNA. 7 FUTURE OTHER CARRIER 9) ANTENNAS (3 PER SECTOR, 3 SECT RS). 2 PROPOSED AT&T MONOPINE WITH FULL BARK CLADDING. BOTTOM OF PINE BRANCHES TO START AT 25'-0" A.G.L. 8 EXISTING BIOCK WALL. 3 PROPOSED 6�-0� HIGH CMU EQUIPMENT ENCLOSURE, WITH CLADDING TO MATCH FUTURE BUILDINGS IN COLOR AND ST(LE. 9 EXISTING CONCRETE CUR6. O4 PROPOSED AT&T GPS MOUNTED TO EQUIPMENT CABINET. 10 FUTURE CONCRETE CURB. TOP OF (N) AT&T MONOPINE. 74.00 A.G.L. )P OF (N) AT&T ANTENNAS. 7.08 AG.L. CENTER OF (N) ATdcT ANTENNAS. 65.00 A.G.L. � � �TOP OF (N) AT&T ANTENNAS. `� 60.08 A.G.L. CENTER OF (N) AT&T ANTENNAS. 58.00 A.G.L `y _ �.. _.� ....�..�... , ! � �� � 0' � � � j V �C C - 2a� o` O�-�. � �'�1" ".�� '�;''���� �r.a'010�3t._ t ,e��x ,�:.m :�... . � � °l"�'� �C3gsr;t�;;" - ('/�-10 � ♦i�e e Or YSO.6�t�.:Y�r.+ ��iiQ � Si n�i se ° Gur At�pd�cr a � v . I o � � m � BOTTOM OF (N) MONOPINE NEEDLES. 25.00 A.G.L. �� � z � .;zi -�� � I '''�� !i '� ��' � . rc.r. ...�¢ �� � "�; � '�' `�st �� � ¢-+���`� ;�.. "� � �• I I �, � ;ti `�`' �k �t x I I _ f �x' � �` '� { f ��,�,,'_ � y ih � � T � �� � � � ., '�>:� �4 � � °� �"�',�*'� � ��� `3'� ;i;�i`b' � � � � +Y ;;JNi�� e, � � ;ti,, r ; ��,y . � � . �x��� �� ! �', .+�..�- ., .' . ,� � y r � # '' ���� :'� � . � �. � � � '4v, � r= �� �, ,,. x ^` � ��.�'� ���:�:� � �,� y„ 0 1 in N � �' { TOP OF (N) CMU ENCLOSURE. i �� 6.00 A.G.L. "'� � i 0 332.67t F.S. io ' i TOP OF F.S. 332.00t T.C. �;� 00.00 A.G.L FUTURE GRADE (FUTURE) _ -_ � --- ----- 0 I �� � 327.10t T.C. TOP OF EXISTING CURB. -05.83 A.GL. - EXISTING GRADE - - 9 NORTH ELEVATION :� '� � �' Y � `�'.! �� � �:� �-.y ��:. "� ` � `9y ,� ��� � ��� �.� � � � ��� � i' ��'.�', /� y ""� , # � i S ..?� �..�:,. � � ., � +`� ��� ��. �"' �. �; � �. �' � � � s'-o" ;� � - � - �., � �, , �t � ' r -� � �� � , , � ;-� , i ? ��` � "f , ;�, f l � � °' � f i , I ', i �� .. ----- �� ,';%� � ,�/ � i i .i �!; ; ;, , �%�, ,�' � , �; , ;; ;,�'�� �;, ;��;;, ,��; „ � ELEVATION GRADES BASED OFF FUTURE SITE , IMPROVEMENTS BY DEVELOPEF SCALE: � 2 3/16"=1'-0" 0 3' 6' ELEVATION KEYNOTES O MO�N�ED D ON T A PR D MONOPINE RANTENNA� TO HAVEORS) 5 EXISTING BUILOING. PINE NEEDLES COVERS OVER EACH ANTENNA. ( ) ( 6 EXISTING LANDSCAPING. PROTECT IN PLACE. � MOUN�ED ON A PR D MONOPINE RANTENNA� 0 HAVE RS) PINE NEEDLES COVERS OVER EACH ANTENNA. 7 FUTURE OTHER CARRIER 9) ANTENNAS (3 PER SECTOR, 3 SECT RS). 2 PROPOSED AT&T MONOPINE WITH FULL BARK CIADDING. BOTTOM OF PINE BRANCHES TO START AT 25�-0" A.G.L. g EXISTING BLOCK WALL. 3 PROPOSED 6�-0` HIGH CMU EQUIPMENT ENCLOSURE, WITH CLADDING TO MATCH FUTURE BUILDINGS IN COLOR qW0 gTYL�. 9 EXISTING CONCRETE CURB. O4 PROPOSED AT&T GPS MOUNTED TO EQUIPMENT CABINET. 10 FUTURE CONCRETE CURB. � � � ,' �'� �.. �. 's'' �if j � � ,� �,�t ".� � <. ir�:»� ��� . � " 4,:. � � . �y� , y�� �" � ���� �� ��� � � �, , __-�..�4�., , ';k �,� � a�"" . ,, �' �"� ` ��f� �,� y � 7D „ � � ��'-- i '� � � J � �� �, 1 ��.,�'��'.�c.,�,�'�_. T�: �' �{,; 9�-0" i �. r. < � � ,i� 1. �, F .: ,; , ; / ! 7 .� ', ;� � F', � + ..,,t ../' %.� Ir, i i s • / �,, � ,.�P� ..ar��, i, �, `��,� *" �1P , _, .: y ✓rF,,E`.s� ., ����,.b �' �`3 b � � 7 , �, � ` .. �Ki' � � � ,�, "� � �� �� 1 � -+� :. �.�':� � ea�. .��, � � � �'".� }��• � � ' ��. . . � ,.+�..,:. �. .a�. . , ���� r ,+M ; � �L' .�� � �' �� � � ;. ' � ��''� ,�, �������� r , �� 4 � �`, �. � �'., _ �� !�, � : �, ,.. � ., 0 I � n TOP OF (N) AT&T ANTEN_NA��S_.��_�_��� 60.08 AG.L. � CENTER OF (N) AT&T ANTENNAS. 58.00 AG.I. e O � 1 � �o in � BOTfOM OF (N) MONOPINE NEEDLES. 25.00 A.G.L. TOP OF (N) CMU ENCLOSURE. 6.00 A.G.L. ', � � 332.67t F.S. o i i I i � , '; � � ;� ELEVATION GRADES BASED OFF FUTURE SITE IMPROVEMENTS BY DEVELOPER. i 332.00t T.C. TOP OF F.S. ------- ------- (FUTURE) - - - - - - - - FUTURE GRADE 00.00 A.G.L. ----------------- 0 ,o ; 327.10t T.C. � TOP OF EXISTING CURB. T N R -05.83 AG.I. 0 SOUTH ELEVATION TOP OF (N) AT&T ANTENNAS 67.08 A.G.L. _ CENTER OF (N) ATdeT ANTENNAS. �� TOP OF (N) AT&T MONOPIN 74.00 A.G. 0 I � N 0 I � � SCALE: � 1 3/16"=1'-0" 0 3' 6' J RA Jeffrer Rome � Aaaoctates, Inc. Architscturo k Tslecommuntcailona 3 San Joaquin Plaza, Suite 155 Nswport Bsach, Caltiornia 92660 Phone: (949) 760-3929 Fax: (949) 760-3931 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SEf OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO ATBcT MOBILITY IS STRICTLY PROHIBITED. STAMP G � N �D ARG� J Y Rp,� �'� � * C-020876 * `�t, o � s F fB.2�'���Q qr f CF CAU� PREPARED FOR Mi " at&t 4420 Rosewood Drive Pleasanton, California 94588 APPROVALS R.F. ENGINEER SITE ACQ. & ZONING FRI('SCnN l'M AT&T CM I OWNER APPROVAL DATE DATE f1ATF DATE DATE PROJECT NAME NOVEMBER DRIVE PROJECT NUMBER CN3242-A RESULTS WAY CUPERTINO, CALIFORNIA 95014 SANTA CLARA COUNTY DRAWING DATES 02/10/09 PRELIMINARY ZD REYIEW (P' O6/08/09 DESIGN CHANGE (P2) 07/02/09 FINAL ZD'S (P3) 01/26/10 SITE RELOCATION (P4) 05/10/10 100% ZD�S (P5) 05/21/10 CLIENT COMMENTS (P6 O6/10/10 CLIENT COMMENTS (P7 OS/16/10 PLANNING COMMENTS (PS) 08/23/10 CLIENT COMMENTS (P9) 08/31/10 REVISED ANTENNA COUNT (f RF REVISION LEVEL 1.6 SHEET TITIE NORTH & SOUTH ELEVATIONS A-2 � M � � w � � Z � U w � O d !� � / ELEVATION KEYNOTES O MOUN�ED D ON T A T PR 6 0POS D MON PINE. 0 HAVE RS) 6 EXISTING LANOSCAPING. PROTECT IN PLACE. PINE NEEDLES COVERS OVER EACH ANTENNA. 7 FUTURE OTHER CARRIER (9) ANTENNAS • 1A PROPOSED AT&T (6) (2 ANTENNAS PER SECTOR, 3 SECTORS) (3 PER SECTOR, 3 SECTORS). MOUNTED ON A PROPOSED MONOPINE. ANTENNA TO HAVE PINE NEEDLES COVERS OVER EACH ANTENNA. g EXISTING BLOCK WALL. 2 PROPOSED AT&T MONOPINE WITH FULL BARK CLADDING, WITH - BOTTOM OF PINE BRANCHES TO START AT 25'-0" A.G.L. 9 EXISTING CONCREfE CURB. 3 PROPOSED 6�-0" HIGH CMU EQUIPMENT ENCLOSURE. CLADDING TO MATCH FUTURE BUILDINGS IN COLOR AND STYLE. 10 FUTURE CONCRETE CURB. 4 PROPOSED AT&T GPS MOUNTED TO E�UIPMENT CABINET. 11 PROPOSED ACCESS STAIR AND REfAINING WALL. 5 EXISTING BUILDING. ------ _ 20 � O— O 3 (�cL,— 201 D O'�' ��'1 �?v'v'�'.$. '�—�t0 1 � A�+�atMs fdws►rf .�� �s30'�3e � t`��31�tft'�f�S�+P�'Jd t-I'f-ro lD�it �l�it�tii�� a Cusc !t s�e' Cusc EAST ELEVATION '`�� j � ���� �{�{, � � ���f�rr �� ' .y� �°,.. ''''^ � ( � f� �� � � �: � �.��� .*� u , ''�s�''k,�c �� ��' ���� . .: ,�r- � ��� � ��k;� �'I I I � �� � � " ��.� t�_ � �`i � ;��� U � � �'�`..�� � ,; ,� ��.:��; '� �:-�,��--•—� � �, .� + �� �,.:, :� � �. �,.... . °� �.....'�Yk:,�.., , ,r� 'l .� 4. 7 r �" � � � � ����;' �� _.� � � � i ` �,�, �� % �: { � �; , y +� � . ," `" �-„�: — � — - E �� �',.'�,z +��t � . �� �; . �, � ,�', �� `:�- 4 - i � ,� �i g� �"' �r' n ,� i � � ��,� �G �.�t '� ��; �;,. #�, s �, �k f� '� � �� �.;� � , ;� *�� , �.�n�. ,� J u � ����, � �` � .x �;'� � - � ,; � �� ,� i�� �r�. - �, �' ,•, , b ' �--1 U '���:�;ro"" � ,�, � ;� �� �.:i,�° ,� �;� �� ' - ° � ^- ,� e � �,�' � ;�'� �..��i''. ,��� a �� . 4 . �f � �: �? i�'. k "f y ' �' �~.. S, [.^ .. � Y 'k* �.;^ �.. � ; �� � � { � � �'°;� sy , y "S%�' ✓ k .. /� �'. ��.. � � �. � �' � , � ; TOP OF (N) ATdcT MONOPINE. � 74.00 A.G.L. TOP OF (N) AT&T ANTENNAS. 67.08 A.G.L. _ CENTER Of (N) AT&T ANTENNAS. �� TOP OF (N) AT&T ANTENNAS. eo.oa ac.�. _ _ _ _ _ _ _ CENTER OF (N) AT&T ANTENNAS, 58.00 A.G.L. 0 � � e e � O ^ � `° � 6 5 �,i�" �t�; � ,t .•' ,f � � � � �r E � . . , �:,� i i� �,�ir s , �...,,,. � � '°�?�` , �r� : c . �• � � -,�,�r . ,,� � , � ,k� �� , , � :: �� f � ; ,,;( ��1 �. (rtF�'; �S � � �'� � � ; , . � . y , - � a:., r-� ' y .; � , �k� � ` � �.,� r ... F V , i , , � � ` ✓ �� Z � ". S ., A ' _... ,,.� .^ r � ��- �j � .Af .. .., . �: . � 1 -.. . _. . . .... '.... . . . .. .. . ..... . . ..... . . . . . � 'JJ � . ..... . . .. .. . .. . . .... ... .._. . _ Cx .. /S ! ��: � , . ; ,.. �: j . 3 * � � � n /^ 'i f / �.. .', .,,.:. ....-, . . . : . ;... . . , �. � ��.. � '.. , � �� .7 �:: � ' ,.� , . ty, f � � � � y y.-4 ' .. >- � ` 6 : v � x� v , � �:: 8 3 4 �` �j� 1 1 r�' S �,. t ,� lr, r ., > r , p / X � ��_ � ' ����f .' y4 f ' * ,9 `7 . . ,.. . � , t �' . , •� � (" y ., 1 ! �' A i ir l �: k ) 4 r/ <1 ' �� YY � �' / i �, / : / �y �� Y (�'�,"( /- ��� `+ _ �.'� / '! / ( 4, � .�F. Po r d .�a � / : l y .. l '� : � � ,.�:.,� ' � I '� ,'�r F � '%z r r � r `'' `�£ � � �'" �� � � TOP OF (N) CMU ENCLOSURE. r". f � .�i : �' ,`, .' �( �° _ s ,. r�' � F �� � , 6.00 A.G.L. � �...�h�� � R LTa�s I I �l : t ��` � �,� r -f ' � 332.67t F.S. � o .'.� f r � � ' i i i , e } .t `` 4 '��,� "Y� / . � « FI ��/ � .:: '' i i nr . r � at �R. u 3. <O ,' �. ' "•'� ^t�S 4k` R;. >x �; ,' , � �, r,.,•`` i 332.00t T.C. i r' h�n_. '.� `f� '��, :��,�'.? �' � TOP OF F.S. �--,�, ,�- ��..--.� + -..�Y �•—�--�,* _ -------- ------- - ----------- ------- --------- --- -- -- ---- - ^, . .• �.. — — — ., . . .a .° . ..- r, 4.. .. . . FUTUR� --- " ; , -1. � , --�_ �-� ''w- --- "'-------- -- � , � 0000 AG ------------------ ---- 3� , —�-- --- --- — . . .L. �� � � � s� � , v } "�UTURE GRADE R .� -` � ` � , ` �. t .�� o ✓ k .. i. JS� 7.^ }; y ' 4 l, ,.,5� µ L � t+ � •� L '� � 3 ... � '..R Nw�.: i � � ' fi Y � . '`. ' Y' .. t .^ .,.. .�,�, .,�.. ` � • �. +- r 27.10t T.C. . . �° � � 3 ` ` , ' ��'' �n � w � � * �' 4 � } b EXISTING GRADE TOP OF EXISTING CURB. ti . . -05.83 A.G.L. 9 ELEVATION GRADES BASED OFF FUTURE SITE IMPROVEMENTS BY DEVELOPER. 0 I � � BOTTOM OF (N) MONOPINE NEEDLES. 25.00 A.G.L. 0 1 � N SCALE: � � 3/16"=1 �-0" 0 3� 6� � �J RA Jsffrs�r Rome � Auociafa, Inc. Architscfure d� Telscommunications 3 Son Jooquln Plaza, Suite 155 Newport Beach, Colifornta 92fi60 Phons: 949 760-3929 Fax: 949� 760-3931 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO ATBcT MOBILITY IS STRICTLY PROHIBITED. STAM P G �NSED ARCj �; V Rp� �'r �� * C-020876 �r f'�� O s FfB.2 qT f OF CA�� PREPARED FOR � at&t 4420 Rosewood Drive Pleasanton, California 94588 APPROVALS R.F. ENGINEER DATE SITE ACQ. & ZONING DATE ERICSSON CM DATE AT&T CM DATE OWNER APPROVAL DATE PROJECT NAME NOVEMBER DRIVE PROJECT NUMBER CN3242—A RESULTS WAY CUPERTINO, CALIFORNIA 95014 SANTA CLARA COUNlY DRAWING DATES 02/10/09 PRELIMINARY ZD REVIEW (P O6/OS/09 DESIGN CHANGE (P2) 07/02/09 FINAL ZD'S (P3) O1/26/10 SITE RELOCATION (P4) 05/10/10 100% ZD'S (P5) OS/21/10 CLIENT COMMENTS (P6) O6/10/10 CLIENT COMMENTS (P7) OS/16/10 PLANNING COMMENTS (P8) 08/23/10 CLIENT COMMENTS (P9) 08/31/10 REVISED ANTENNA COUNT (I RFDS REVISION LEVEL 1.6 SHEET TITLE EAST ELEVATION A-3 M n O O� O � � � Z � U W � � a a � r Title Report # 1 PREPARED BV: FIRST AMERICAN TITLE COMPANY ORDER NO.: 0714-3327625 DATED: JUNE 23, 2009 Legal Description REAL PROPERTY IN THE CITY OF CUPERTINO, COUNTY OF SANTA CLARA, STA1E OF CALIFORNIA, DESCRIBED AS FOLLOWS: PARCEL A: ALL THAT PORTION OF SAI� LAND AS DESCRIBED AS ADJUSTED PARCEL 3 AS SHOWN IN THAT CERTAIN l0T LINE ADJUSTMENT RECORDED SEPTEMBER 11, 2001 AS DOCUMENT N0. 15862177 AND AS FURTHER DESCRIBED BELOW: BEING AlL OF PARCEL 3, AS SHOWN UPON 1HAi CERTAIN PARCEL MAP WHICH MAP WAS FILED FOR RECORD IN THE OFFICE OF THE RECORDER OF THE COUN?Y OF SANTA CLARA, STATE OF CALIFORNIA ON APRIL 12, 1979 IN BOOK 439 Of MAPS AT PAGES 12 AND 13 AND BEINC A PORTION OF THE LANDS DESCRIBED IN THAT CERTAIN DOCUMENT RECORDED OCTOBER 14, 1975 IN BOOK 8662 AT PAGE 46 IN iHE OFFICE OF THE RECORDER OF SANTA CIARA COUNTY AND BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNINC AT THE SOUTHWESTERLY CORNER OF SAID PARCEL; THENCE ALONG THE WESTERLY LINE OF SAID PARCEL NORTH 00' 01' 00' WES1 241.44 FEET TO THE SOUTHWESTERLY CORNER OF THE LANDS DESCRIBED IN SAID BOOK 8662 A7 PACE 46; THENCE ALONG THE WESTERLY LINE OF SAID LANDS NORTH 00' 00' 33" WEST 318.23 FEET; THENCE SOUTH 89' S6' 46' EAS 274.02 FEET TO THE EASTERLY UNE OF SAID LANDS; THENCE ALONG SAID LINE SOUTH 19' O6 48' EAST 335.47 FEET TO 7HE NORTHEASTERLY CORNER OF SAID PARCEL; THENCE ALONG TFI EASTERLY LINE OF SAID PARCEL SOUTH 19' 06' 48' EAST 293.23 FEET TO 7HE SOUTHEASTERL CORNER OF SAID PARCEL; THENCE ALONC THE SOUTHERLY LINE OF SAID PARCEL NORTH B2' 2' 51" WEST 261.05 FEET; THENCE CONTINUING ALONG SAID UNE NORTH 89' S7' 24' WEST 220.9 FEET TO 7HE POINT OF BEGINNING. PARCEL B: PARCEL 2, AS SHOWN UPON THAT CERTAIN PARCEL MAP WHICH MAP WAS FlLED FOR RECORO I THE OFFICE OF THE RECORDER OF THE COUNTY Of SANTA CLARA, STATE OF CAIIFORNIA ON APRIL 12, 1979 IN BOOK 439 �F MAPS AT PAGES 12 AND 13. Easements # 1 4O EASEMENT FOR PUBUC SERVICE AND SANITARY SEWER AS SHOWN ON PARCEL MAP RECORDED IN BOOK 407, PACES 28 k 29 OF MAPS. (PIOTTED HEREON) O 5 EASEMENT FOR PUBLIC SERVICE ANO SANITARY SEWER AS SHOWN ON PARCEL MAP RECORDED IN BOOK 439, PAGES 12 dc 13 OF MAPS. (PLOTTED HEREON) 16 EASEMENT FOR INGRESS, EGRESS, ACCE55 AND PARKING FOR VEHICULAR ANO PEDESTRIAN TRAFFIC RECORDED AS DOC. N0. 16105737, O.R. (BLANKET IN NATURE) 17 PEDESTRIAN PATH EASEMENT RECORDED AS DOC. N0. 16334J79, O.R. (PLOTTED HEREON) Title Report #2 PREPARED BV: FIRST AMERICAN TITLE COMPANY ORDER NO.: 0714-3430588 DATED: DECEMBER 14, 2009 Legal Description REAL PROPERTY IN THE CITY OF CUPERTINO COUNTY OF SANTA CLARA STA OF CALIFORNIA DESCRIBED AS FOLLOWS: � PARCEL A, AS SHOWN UPON THAT CERTAIN PARCEL MAP WHICH MAP WAS FlLED FOR RECORD IN THE OFFICE Of THE RECORDER OF THE CDUNTY OF SANTA CLARA, STATE OF CALIFORNIA ON JANUARY 23, 1980 IN BOOK 479 OF MAPS AT PAGE 1. Easements THERE ARE NO EASEIAENTS USTED IN THE EXCEPTIONS Of SAID TITLE REPORT p2. Assessor's Parcel Nos. 357-20-041, 357-20-046 dc 357-18-035 Geographic Coordinates at Proposed Monopine 1983 DATUM: LATI7UOE 37' 19' 10.18' N LONGITUDE 122' 03' 09.82" W 1927 DATUM: LATI7UDE 37' 19' 10.39" N LONGITUDE 122' 03' 05.96' W ELEVATION = 334.5 FEET ABOVE IAEAN SEA LEVEL (A.M.S.L.) CERTIFICATION: THE LATITUDE AND LONGITUDE SHOWN ABOVE ARE ACCURATE TO NATHIN +/- 15 FEET HORIZONTALLY AND THAT iHE ELEVAT10N5 SHOWN ABOVE ARE ACCURA7E TO MAIHIN +/- 3 FEET VERTICALLY. THE HORIZONTAL DATUM (GEOGRAPHIC COORDINATES) IS IN TERMS OF 1HE NOR1H AMERICAN DAlUM OF 1983 (NAD 83) AND IS EXPRESSED IN DEGREES ('), MINUlES (') AND SECONDS ('), TO THE NEAREST HUNDREDiH OF A SECOND. THE VERIICAL DAlUM (ELEVATIONS) IS IN 7ERM5 OF THE NOR1H AMERICAN VERTICAL DAillM OF 1988 (NAVO 88) AND IS DETERMINED TO THE NEAREST 7ENiH OF A FOOT. Basis of Bearings iHE STATE PLANE COORDINAIE SYSTEM OF 1983 (NAD 83), CALIFORNIA ZONE 3. Bench Mark THE CALIFORNIA SPAiIAL REFERENCE C.O.R.S �P273', ELEVATION = 656.17 FEET (NAVD BB). Date of Survey JANUARY 20, 2010 ;; %ii; ��; �� ANTENNA �� ",, � � . r , �,,, ��� ,,, ���� �'�' '"� %i: EXISTING BUIIDING " iii "�% �ii �:; ��� ��. ii, �'� ii , j iii_ EXISiINC BUIIDINC iii ���-.,,,,�,�� ,, ... ,,, � ��i ii,i iiii ��ii ��iii' iiiii, ii�. "�ii �/iii ��iiiii �iiiiiiii �iii /i . iii , iiii, iiiii.._ iiii.i„ iiii „ ii ,,,, �� � %i: �i iii �ii i� � I i�� ij� �,;; �,,; �;�; . r ��;; ����� �� CANOPY �iiiii. iiiiiiii ��.iiii.�ii � - - - � _ 49.4 T P 343.SSTOP 336.11F$� 33 .84FS N ------------ - ------�--------- _ _ --- !NEST -- 150.00 =--- � � I N � 345.44TOP GP• GP. GP•GP• � GP• � Cq 336.75F5 n 336.40F P� E � �, 336.99F5 �• 343.23FS =�� - - ,,,,,,,, ��,�,,,�, ,,,,,,,,�,'/,;;"/," � ;;;;'' ' ', 337.OBF$ i ��i;�;!!!�iiii:i;�iiiiiiii;;��!�iii�ii.iiiiiiiii,!iiiii�i/ ' iii; 35170TOP 357.4BTOP ��%� I ��,, ���� / ';'% AT PROI�OSED MONOPINE ;��� „� GEOGRAPHIC COORDINATE; �ii LAT.= 37'19'10.18"N �'� LONG.= 122'03'09.82"W �NAD i�i ///" '�� EXISTING BUILDING �i i, ;��� ,, � (LOYYER ROOF) (UPPER ROOF) �ii �:: ,;� ,; ii i � iii ���, r 357.� ii�i i ii' �' �! ii,, ".iiii'��'��iiii,' i ,,lri i x � �)j�; � iiii„��ii,iii„� (� L- 2o f O- O�-# At'i�T�,a�:��. -r�-��o -�� A�c/das tiu�' --- --*-- q_l�/o 4� .��s��������r� �'���ba�is�����a _,_.,_ - �}O�t O UE S3�*tl�tilY"� Y Ci�SC I�Ii1t0 1' �;;. ii i %i; �ii �i i ,,�� i ii i% � ' i, � ,,, ;,, „� ii i 'iii ;�;� �„ i i i: i �i i ��' �ii �iii i�i i i %/ i� � � OP � � � � Access Route THAT PORt10N OF LAND IN THE CITY OF CUPERTINO, COUNTY OF SANTA CLARA, STATE OF CALIFORNIA, AS DESCRIBED AS ADJUSTED PARCEL 3 AS SHOWN IN THAT CERTAIN LOT LINE ADJUSTMENT RECORDED SEPTEMBER 11, 2001 AS DOCUMENT N0. 15862177 TOCETHER WITH THAT PORTION OF PARCEL 2, AS SHOWN UPON THAT CERTAIN PARCEL MAP WHICH MAP WAS FILED FOR RECORD IN THE OFFICE OF THE RECORDER OF SAID COUNTV ON APRIL 12, I 1979 IN BOOK 439 OF MAPS AT PAGES 12 AND 13, BEING A STRIP OF LAND, 12.00 FEET WIDE, LYINC 6.00 FEET ON EACH SIDE OF THE FOLLOWINC DESCRIBED CENTERLINE: � COMMENCING AT THE MOST SOUTHERLY CORNER OF SAID PARCEL 2, SAID POINT BEING ON A CURVE CONCAVE SOUTHEASTERLY, HAVING A RADIUS DF 387.00 FEET, A RADIAL LINE THROUGH SAID POINT BEARS N67'23'21�W, SAI� CURVE ALSO BEING THE NORTHWESTERLY RIGHT OF WAY OF BU88 ROAD AS SHOWN ON SAID MAP; THENCE NORTHEASTERLY ALONG SAID CURVE, THROUGH A CENTRAL ANGIE OF 12'45'S0', AN ARC DISTANCE OF 86.21 FEET TO THE POINT OF BEGINNING; THENCE N55'35'21'W, 363.76 FEET; THENCE NORTH, 67.74 I FEET, THENCE EAST, 207.88 FEET, THENCE N18'19'01'W, 727.27 FEET, THENCE WEST, 311.34, THENCE NOR7H, 166.54 fEET; 1NENCE WEST, 30.00 FEET TO A POINT HEREINAFTER A REFERRED TO AS POINT 'A' AND THE END OF SAID STRIP. � Fi�SS�I[9 Lease Area Detail SCALE: 1"=20' _ __ _. }33.63F5 � � � u ti _ z _ � Y = __.�_. . e - ----� - - _..,. .,,. ..,,,. _,.? � 351.26TOP � � 1 f� PROPOSED ATdcT � � 5' WIDE UTILITY ROU1E � N . .._. . . .��531.37FS O I � 331.89TC � � 356.13TOP • I 331.07TC � 334.35NG i 332.16TC z 4 � 330.B6TC � ^ AS�; I332.33TOE 3 , aao.sz�s �n � � � I 358.38TOP N � ^ N ~ � 335.45N(; �� POINT'A � m ' � WEST � 33D.62TC o v � �_ 3 ��Q� . � Z _ _� _ I PROPOSED � �iC � 1 ATAcT � � �' I I358.50TOP 42.5'z22' ' � . � � LEASE AREA � Y I wESr.- � �a � a I i � 22.00' POINT "B" i I � � 331.99T 355.08TOP I I � � � � 330.27TC � � � � ,,, I f� PROPOSED AT&T 12' WIDE '� � NON-EXCLUSIVE ACCESS ROUTE ' � ! in . 3�0.15F � m ; � ' 330.93NG I � g `��' � � ' 357.36TOP 330.75T� I � 330.22TC T � " ,��� � I � � z 330. ..____.... _.. . .. 3.H � i � . � � �TV � I ! .�__ � I � � � I � 33o.2�rc ' ....V � _ � _ _ _ 335.7&JC� i � I Y 364A3TOP � I � �. � ............. a.... I � 330.9 NG� � � � � 6' I 6� � m � _ _ I I 330.91 I C, I � _ ... . . 330.16FS I � � � I . P _ � I � I � 330.91TC � z 330.�9TC I 5 I I a 358.46TOP � I 330.B1TC ( I � I � d qqq ��_��_"""��` � � j: 335.uw/G � I L _ _ - _ zF , , ------- � 3y5.83NC i - - - I � I �--------------- 3 335.52NC I = 336.57F5 I � 334.11FSa Lease Area g � BEGINNING AT POINT 'A' AS DESCRIBED A80VE; THENCE SOUTH, 17.25 FEET TO A POINT � I HEREINAFTER REFERRED TO AS POINT 'B'; THENCE CONTINUING SOUTH, 4.00 FEET; THENCE � I WEST, 22.00 FEET; 7HENCE NOR7H, 4250 FEET; THENCE EAST, 22.00 FEET; THENCE 3 SOUTH, 21.25 FEET TO THE POINT OF BEGINNING. Y CONTAINING 935 SQUARE FEET, MORE OR LESS. m I Utility Route I BEING A STRIP OF LAND, 5.00 FEET WIDE, LYINC 250 FEET ON EACH SIDE OF THE FOLLON1NG DESCRIBED CEN7ERLINE: BEGINNING AT POINT 'B� AS DESCRIBED ABOVE; 1HENCE EAST, 5.00 FEET; THENCE NORTH, 84.00 FEET; iHENCE WEST, 150.00 FEET; THENCE S67'07'S4'W, 72.25 FEET TO THE END OF SAID STRIP. I � � � 33B.47F5 x ti Q 342.40F5 ��;ii i ii, W i� ii i �ii z �� o � ii - ii: m ,,. �%; _ � ii, G //� N �i X �� W '/ i ;; i ii. ii: ,,, �;; , '�; � _ LOMITA AVENUE _ � � _ _ � I I I � I I I - - �� �a I I '�� I I ��� � f� PROPOSED AT&T � 33 . FS I� - �� 5' NADE UT1lITY ROUTE '�o V � � Z PRO�SED ATdcT A� � O 42.5' 22' LEASE AREA z I � ` � � �5°°' 3 � s � � � I �O AR �E� R ��� 3 � � N � I � I pJUS ��p,p� ; ZO�� VI {•', _}.� i O - (�" RNSj S Np .�5�62,��1- - � 1.��� I\ N�1-�� GRAPHIC SCALE ` • LL _ __ sL _ ti? _ 3„_3a� _ _ _ � ioo o so ioo ' I � -----------� \ �� FEET � � �, � � � J �\ � \ EXISTING BUILDING \ � �\ - - 1 7 � \ ` � � ��\ \ E7(ISTING �'\ 343.3BFS BUILDING � � 343.83FS • \� � � \� \� � ` I � E%IS11NC BUIIDINC ���� � � \� \� \ I I � �� � \ � � � : � a GE _o�+ � � �. �, �„ ���� � � � �. P N 3� � � M ' � \ � � \� \� \ � � M P � 3 ���`� \� � PA R�E� 39/ � 2- � � �� \ P•��� f� PROPOSED ATEcT 12' HADE �\� \ NON-EXCLUSIVE ACCESS ROUTE \ I ��\� \� � �� �\ \� � \ r - Fq$1 - - _- - 207_88'� � -----, _ _ .� _ _ �rJ i ----- � \ �z�,/� � I "� " � \� � � S �JS�� . 4 5 \ � � I � \ � I \ R�7.� ��SG`I`S; � � � P.O.B. \� I lrN,� �Lq �s \ � 1 �f � �� `� � P A RGE� � �r,�,�°�?,;�` � ���2�' ��oo' � � I aP• N ' �-�' � I R ,�'". � I P.O.C. I / � I I � I � I � � _ _ _ _ - - _ _ _ - - _ _ - / McCLELLAN �ROAD � i i , I I I FD MON. WEII I PER P.M. 284/35 � _ OLIVE ' AVENUE �n z' eRass oisK - NO REFERENCE _ �I _ _ � I Z I �� I I Q S�ee� Lease Q Ar�aLDetail ti WI 5 � � - - FS FlNISH SURFACE NG NATURAL CROUND � POWER POLE o RETAININC/BLOCK WALL EC ELEC7RlC CABINfT � CONCREIF PAVEMENT PINE 1REE TREE TC TOP OF CURB --- PROPERTY LINE -o-o- WROUGNT IRON FENCE � CNA/N LINK FENCE �^ � GA 1F TR 1RANSFORMER TOP TOP OF STRUCTURE B CEODEIIC COORDINATES TOE r0E OF SLOPE � FIRE HYDRANT/FlRE 8EM fLEC7RIC MEIER � ELECTRIC VAULT � � ��� ��' � �� �1 BLOCK WALL �� Boundary Detail SCALE: 1"=100' �J RA Jeffrey Rome dc Associates, Inc. Architecture k Telecommunlcations 3 San Joaquin Plaza, Sui1e 155 Newport Beach, Calitornia 92660 Phone: 949 760-3929 Fax: 949 760-3931 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO ATBcT MOBILITY IS STRICTLY PROHIBITED. CONSULTANT C�L ���� SUAVEYING, INC. 411 Janla Cir., Suite 205, Corone, CA928B0 Phone:951-280-9960 Fex:951-280-9748 Toll Frea: 800-CALVADA www.caNada.com JOB N0. 10042 PREPARED FOR at&t 4430 Rosewood Drive Pleasanton, California 94588 APPROVALS R. F. DATE I SAC AND ZONING DATE ERICSSON CM DATE AT&T CM DATE OWNER APPROVAL DATE PROJECT NAME NOVEMBER DRIVE PROJECT NUMBER CN3242-A RESULTS WAY CUPERTINO, CA 95014 SANTA CLARA COUNTY DATE DESCRIPTION BY 01/22/10 PRELIMINARY MN 04/14/10 TITLE REPORT / FINAL RA'. OS/21/10 ACCESS EASEMENT UPDATE GP SHEET TITLE TOPOGRAPHIC SURVEY C-1 SHEET 1 OF 1 \ � � � �