Loading...
HomeMy WebLinkAboutMMP-2026-002 - A1 SITE PLANCARVER DRIVE (60') N0°23'00"W 51.00' S8 9 ° 3 7 ' 0 0 " W 1 0 0 . 0 0 ' S0°23'00"E 51.00' N8 9 ° 3 7 ' 0 0 " E 1 0 0 . 0 0 ' CARVER DRIVE (60') N0°23'00"W 51.00' 5' P . U . E . 5' P . U . E . PROPOSED FIRST FLOOR SIDE SETBACK 5'-0" REQD. FIRST FLOOR SIDE SETBACK PROPOSED SECOND FLOOR SIDE SETBACK 4'-0" NEW DRIVEWAY CURB CUT PER DETAIL 1-20 NE W 4 " D I A P V C S E W E R L I N E ENCROACHMENT PERMIT REQUIRED NE W 1 1 2" D I A W A T E R L I N E MAX. DRIVEWAY CUT BACKFLOW PREVENTOR DEVICE PR O P O S E D F I R S T F L O O R F R O N T S E T B A C K 20 ' - 0 " PR O P O S E D S E C O N D F L O O R F R O N T S E T B A C K 27 ' - 5 " OFF-SITE PARKING INSTALL NEW PLCO PER DISTRICT STANDARD SEE A/ T0 NEW ONE STORY RESIDENCE NEW SECOND FLOOR ADU NEW DRIVEWAY NEW GARAGE OPEN PATIO 9'-6" 6'-11 1/2" PROPOSED SECOND FLOOR SIDE SETBACK PR O P O S E D FI R S T F L O O R SI D E S E T B A C K 5' - 0 " 6'-8 1/2" 5'-0" REQD. & PROPOSED FIRST FLOOR SIDE SETBACK COVERED PORCH COVERED PORCH HEAT PUMP HEAT PUMP 4'-0" TO EAVE TO EAVEPR O P O S E D S E C O N D F L O O R R E A R S E T B A C K 35 ' - 8 " x x xx SI T E P L A N AR E A S U M M A R Y VI C I N I T Y M A P revisions by drawn checked date scale job no. sheet of sheets 1/8" = 1'-0" A1 AM STATE OF CA L IFORNIA L I CENSE D A RCHITEC T AD I T I M U K H E R J E E NORTH 1.8.26 A R C H I T E C T L I C . C 3 1 6 1 1 1 4 4 8 S . S T E L L I N G R O A D CU P E R T I N O , C A L I F O R N I A AD I T I @ A M A R C H I T E C T S C A . C O M 40 8 4 5 5 3 7 9 3 SITE PLAN & HORIZONTAL CONTROL PLAN THE HORIZONTAL CONTROL PLAN IS PREPARED BASED ON THE BOUNDARY SURVEY PREPARED BY THE PROJECT'S LICENSED SURVEYOR. 1/8" = 1'-0" VICINITY MAP SAW CUT 1’ MIN. OF EXISTING AC PAVEMENT ALONG THE DRIVEWAY TO BE REMOVED. REPLACE ASPHALT WITH A MINIMUM 12” AC DEEP LIFT PLUG.” REMOVE AND REPLACE EXISTING DRIVEWAY AND CURB CUT WITH CURB, GUTTER, AND SIDEWALK PER CITY STANDARD DETAILS 1-16 AND 1-19, AS DIRECTED BY THE PUBLIC WORKS INSPECTOR. ENSURE GRADES MATCH AT THE BACK OF SIDEWALK TO ALLOW FOR POSITIVE DRAINAGE TOWARDS THE PUBLIC STREET, AND THE CURB AND GUTTER ALSO PROVIDES FOR POSITIVE DRAINAGE. SAW CUT 1’ MIN. OF EXISTING AC PAVEMENT ALONG THE DRIVEWAY TO BE REMOVED. REPLACE ASPHALT WITH A MINIMUM 12” AC DEEP LIFT PLUG.” PROJECT CONSTRUCTION ACTIVITIES WILL CONFORM TO THE APPLICABLE REQUIREMENTS OF THE CITY CODE CHAPTER 17.04. R401.3 DRAINAGE SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT DOES NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE SHALL FALL NOT FEWER THAN 6 INCHES (152 MM) WITHIN THE FIRST 10 FEET (3048 MM). EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE BUILDING FOUNDATION SHALL BE SLOPED NOT LESS THAN 2 PERCENT AWAY FROM THE BUILDING. MECHANICAL EQUIPMENT SHALL BE LOCATED SUCH THAT SOUND PRESSURE LEVEL GENERATED BY THE USE OF THE UNIT DOES NOT EXCEED 50 DECIBELS AT ANY PROPERTY LINE. ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER AT A POINT OF DISCHARGE (OR THE INLET OF AN APPROVED DRAINAGE DEVICE), A MINIMUM OF 12 INCHES PLUS 2%. (CBC 1808.7.4) (CRC R403.1.7.3) PROJECT CONSTRUCTION ACTIVITIES WILL COMPLY WITH THE BAY AREA AIR QUALITY MANAGEMENT DISTRICT BASIC CONTROL MEASURES INCLUDED IN THE LATEST VERSION OF BAAQMD’S CEQA AIR QUALITY GUIDELINES TO CONTROL FUGITIVE DUST DURING DEMOLITION, GROUND DISTURBING ACTIVITIES, AND/OR CONSTRUCTION. THE PROJECT IS SUBJECT TO THE STANDARDS AND REQUIREMENTS OF CITY CODE CHAPTER 17.04. THESE STANDARDS INCLUDE MEASURES TO PROTECT NESTING BIRDS SHOULD CONSTRUCTION TAKE PLACE BETWEEN FEBRUARY 1 AND AUGUST 31. IT IS THE OWNER’S AND CONTRACTOR’S RESPONSIBILITY TO ENSURE FENCE LOCATION AND HEIGHT ARE INSTALLED PER THE APPROVED PLAN. FENCES SHALL NOT ENCROACH INTO PUBLIC RIGHT OF WAY. SEE CIVIL DRAWINGS FOR THE GRADING AND DRAINAGE PLANS SEE LANDSCAPE PACKAGE FOR PRIVACY SCREENING UNDERGROUND GAS PIPING INSTALLATION SHALL COMPLY WITH CPC §1210.0. SPECIFY THE FOLLOWING: a.COVER REQUIREMENTS PER CPC §1210.1.1. b.TRENCHES PER CPC §1210.1.2. c.PROTECTION AGAINST CORROSION PER CPC §1210.1.3. d.PIPING THROUGH FOUNDATION WALL CPC §1210.1.5. PLANNING NOTES DRAINAGE NOTES FENCES SHALL NOT BE GREATER THAN 6’ IN HEIGHT IN ALL SIDE AND REAR YARD AREAS, AND A MAXIMUM OF 3’ IN HEIGHT IN THE FRONT YARD AREA. WHERE 6’ HIGH FENCES ARE ALLOWED, 8’ MAY BE PERMITTED WITH A BUILDING PERMIT AND NEIGHBOR APPROVAL. BUILDING OCCUPANCY GROUP R3 & U TYPE OF CONSTRUCTION V - B STORIES 2 W/O BASEMENT AUTOMATIC SPRINKLERS YES CITY CODE SECTION 17.04.050, GROUND DISTURBING ACTIVITIES (I.E. DEMOLITION, GRADING, TREE REMOVAL, AND GENERAL CONSTRUCTION ACTIVITIES) WHICH OCCUR BETWEEN FEBRUARY 1 AND AUGUST 31 REQUIRE THE PERFORMANCE AND SUBMITTAL OF A PRECONSTRUCTION SURVEY BY A QUALIFIED ORNITHOLOGIST NO MORE THAN SEVEN DAYS PRIOR TO THE START OF GROUND DISTURBING ACTIVITIES. ADDITIONAL ACTIONS MAY BE REQUIRED BASED ON THE RESULTS OF THE PRECONSTRUCTION SURVEY, AS OUTLINED IN CITY CODE SECTION 17.04.050. GROUND DISTURBING ACTIVITIES WHICH OCCUR BETWEEN SEPTEMBER 1 AND JANUARY 31 DO NOT REQUIRE A PRECONSTRUCTION SURVEY UNDER THIS CITY CODE SECTION. SHOULD GROUND DISTURBING ACTIVITIES OCCUR BETWEEN FEBRUARY 1 AND AUGUST 31, A PRECONSTRUCTION SURVEY, COMPLETED NO MORE THAN SEVEN DAYS BEFORE THE START OF ACTIVITIES, WILL BE SUBMITTED TO THE CITY IN COMPLIANCE WITH CITY CODE SECTION 17.04.050. ADDITIONALLY, IF FEASIBLE, TREE REMOVAL AND/OR PRUNING WILL BE COMPLETED BEFORE THE START OF THE NESTING SEASON (FEBRUARY 1 TO AUGUST 31) TO HELP PRECLUDE NESTING. LEGEND PROJECT SUMMARY PROJECT ADDRESS 10621 CARVER DRIVE. APN 375 34 046 ZONING DISTRICT R1-7.5 LAND USE LOW RES 1-6 DU/ AC FLOOD ZONE NO NET LOT AREA 5100 SF. PRIOR PERMIT AREA CALCULATION ALLOWABLE FLOOR AREA 2295 S.F. (45%) ALLOWABLE LOT COVERAGE 2550 S.F. (45% +5%) ALLOWABLE BUILDING HT.16 FT. PROPOSED BUILDING HT.15'-11" FLOOR AREA SUMMARY NEW FIRST FLOOR 2058.9 S.F. NEW 1 CAR GARAGE 235.7 S.F. TOTAL PROPOSED FLOOR AREA 2294.6 S.F. ( 44.9%) ALLOWABLE FLOOR AREA 2295 S.F. LOT COVERAGE SUMMARY NEW FIRST FLOOR 2058.8 S.F. NEW FRONT PORCH 45 S.F. NEW 1 CAR GARAGE 235.7 S.F. TOTAL EAVE PROJECTION 201.4 S.F. PROPOSED COVERAGE 2540.9 S.F. ( 49.8 % ) ADU ( SECOND FLOOR) 799.13 S.F SB9 SECOND FLR ADU FRONT SETBACK 20'-0"27'-5" LEFT SIDE 5'-0"9'-6" REAR SETBACK 5'-0"35'-8" RIGHT SIDE 5'-0"6'-11 1/2" FIRE SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13D SHALL BE UNDER A SEPARATE PERMIT AND IS APPLIED FOR WITH THE SCCFD STANDARDS. WATER SUPPLY REQUIREMENTS: POTABLE WATER SUPPLIES SHALL BE PROTECTED FROM CONTAMINATION CAUSED BY FIRE PROTECTION WATER SUPPLIES. IT IS THE RESPONSIBILITY OF THE APPLICANT AND ANY CONTRACTORS AN SUBCONTRACTORS TO CONTACT THE WATER PURVEYOR SUPPLYING THE SITE OF SUCH PROJECT, AND TO COMPLY WITH THE REQUIREMENTS OF THAT PURVEYOR. SUCH REQUIREMENTS SHALL BE INCORPORATED INTO THE DESIGN OF ANY WATER-BASED FIRE PROTECTION SYSTEMS, AND/OR FIRE SUPPRESSION WATER SUPPLY SYSTEMS OR STORAGE CONTAINERS THAT MAY BE PHYSICALLY CONNECTED IN ANY MANNER TO AN APPLIANCE CAPABLE OF CAUSING CONTAMINATION OF THE POTABLE WATER SUPPLY OF THE PURVEYOR OF RECORD. FINAL APPROVAL OF THE SYSTEM(S) UNDER CONSIDERATION WILL NOT BE GRANTED BY THIS OFFICE UNTIL COMPLIANCE WITH THE REQUIREMENTS OF THE WATER PURVEYOR OF RECORD ARE DOCUMENTED BY THAT PURVEYOR AS HAVING BEEN MET BY THE APPLICANT(S). 2019 CFC SEC. 903.3.5 AND HEALTH AND SAFETY CODE 13114.7. STREET TREE TO BE INSTALLED BY THE CITY. UPON PROJECT COMPLETION, THE PROPERTY OWNER SHALL PREPARE AN ADEQUATE PLANTING AREA AND CONTACT THE CITY AT 408-777-3269 TO ARRANGE FOR THE TREE INSTALLATION. WATERPROOFING NOTE: WATERPROOFING MEASURES DELINEATED IN THE PLAN SET ARE SUGGESTIONS ONLY. OWNER AND CONTRACTOR SHALL CONSULT WITH A WATERPROOFING EXPERT FOR PROPER INSTALLATION METHODS FOR ALL AREAS REQUIRING WATERPROOFING PRIOR TO BUILDING PERMIT ISSUANCE, PLEASE PROVIDE SPECIFICATION SHEETS FOR THE PROPOSED AC UNIT AND INDICATE THE SETBACK OF THE UNIT FROM THE NEAREST PROPERTY LINE. FOR RESIDENTIAL PROPERTIES, THE DBA LEVEL AT THE RECEIVING PROPERTY LINE SHALL NOT EXCEED 50 DBA. IT IS THE OWNER’S AND CONTRACTOR’S RESPONSIBILITY TO ENSURE FENCE LOCATION AND HEIGHT ARE INSTALLED PER THE APPROVED PLAN. FENCES SHALL NOT ENCROACH INTO PUBLIC RIGHT OF WAY. THE SLOPE OF GRADE AWAY FROM EXTERIOR FOUNDATIONS TO BE 6 INCHES MINIMUM WITHIN 10 FEET (5% MINIMUM). AT IMPERVIOUS SURFACES, A MINIMUM 2% SLOPE IS PERMITTED CONTRACTOR SHALL CONTACT PROJECT’S CIVIL ENGINEER AND PUBLIC WORKS INSPECTOR FOR INSTALLATION AND INSPECTION OF ON-SITE GRADING & DRAINAGE FACILITIES. A LETTER FROM THE CIVIL ENGINEER WILL BE REQUIRED TO CERTIFY THAT GRADING AND DRAINAGE SYSTEMS ARE INSTALLED PER DESIGN PRIOR TO PROJECT ACCEPTANCE. REMOVE AND REPLACE BROKEN CURB AND GUTTER AS DIRECTED BY THE PUBLIC WORKS INSPECTOR. ENSURE CURB AND GUTTER PROVIDES FOR POSITIVE DRAINAGE. SAW CUT 1’ MIN. OF EXISTING AC PAVEMENT ALONG THE CURB & GUTTER TO BE REMOVED. REPLACE ASPHALT WITH A MINIMUM 12” AC DEEP LIFT PLUG.” 7.15.25 BP N E W O N E S T O R Y R E S I D E N C E W I T H SE C O N D S T O R Y A D U F O R T R A C Y H S U 1 0 6 2 1 C A R V E R D R I V E C U P E R T I N O , C A L I F O R N I A