Loading...
HomeMy WebLinkAboutRM-2025-011 - A1 Site PlansEXISTING SITE PLAN SCALE 1 8"= 1'-0" 1 P1 APRIL 28, 2025 A1 VA N D E R H A E G E N - W A N R E S I D E N C E 76 4 1 P E A C H B L O S S O M D R I V E , C U P E R T I O N O , C A 9 5 0 1 4 CO R N E L I A H A B E R RE S I D E N T I A L D E S I G N PH O N E 6 5 0 7 8 7 1 1 9 7 co r n e l i a . h a b e r @ g m a i l . c o m DATE REVISIONS Cornelia Haber PROPOSED SITE PLAN SCALE 1 8"= 1'-0" 2 mARCH 18, 2025 P2 AUGUST 25, 2025 FRONT YARD IMPERVIOUS SURFACE CALCULATION EXTERIOR LIGHTING SPECIFICATIONS P3 OCTOBER 28, 2025 P3 (E) GAS LINE V.I.F. (E) SEWER LINE V.I.F. (e) water meter (E) WATER LINE V.I.F. (E) GAS METER (e) ELECTRIC METER property line 60' property line 60' pr o p e r t y l i n e 1 0 0 ' MINIMUM SETBACK LINE FRONT SETBACK LINE REAR SETBACK LINE MINIMUM SETBACK LINE 5' 5' (E) LANDSCAPING TO REMAIN ℄ EXISTING FIRST FLOOR EXISTING GARAGE (E) DRIVEWAY OVERHANG LINE 20 ' 20 ' EXISTING SECOND FLOOR 5' P. S . E . W. C . E . 24 ' - 9 " 5' 5'-8" EXISTING NON-CONFORMING SETBACK LINE REQUIRED SETBACK LINE 9'-91 4" PEACH BLOSSOM DRIVE 30 ' CURB & GUTTER EDGE OF PAVEMENT SIDEWALK (e) ELECTRICAL POLE AND JUNCTION BOX 30" ASH TREE TO BE REMOVED 15" FRUIT TREE TO BE REMOVED 15" MAPLE TREE TO REMAIN 15" MAPLE TREE TO BE REMOVED 18" MAPLE TREE TO BE REMOVED 15" PALM TREE TO REMAIN EXISTING PORCH OVERHANG LINE 5'-23 4" EXISTING SETBACK LINE 8" SWEET GUM TREE TO REMAIN ADU OVERHANG LINE (E) GAS LINE V.I.F. (E) SEWER LINE V.I.F. (e) water meter (E) WATER LINE V.I.F. (e) ELECTRIC METER property line 60' property line 60' pr o p e r t y l i n e 1 0 0 ' MINIMUM SETBACK LINE FRONT SETBACK LINE REAR SETBACK LINE MINIMUM SETBACK LINE 5' 5' (E) LANDSCAPING TO REMAIN ℄ EXISTING FIRST FLOOR EXISTING GARAGE (E) DRIVEWAY (E) CO OVERHANG LINE 20 ' 20 ' EXISTING SECOND FLOOR 404.9 SQ.FT. PORCH 40.3 SQ.FT. 5' P. S . E . W. C . E . 24 ' - 9 " LANDING LANDING 5' 5'-8" EXISTING NON-CONFORMING SETBACK LINE REQUIRED SETBACK LINE 9'-91 4" PEACH BLOSSOM DRIVE 30 ' CURB & GUTTER EDGE OF PAVEMENT SIDEWALK ADU ADDITION ADDITION 5% 5% 5% 5% 5% 5%5% 5% (e) ELECTRICAL POLE AND JUNCTION BOX 15" MAPLE TREE TO REMAIN 15" PALM TREE TO REMAIN DS DS DS DS DS DS DS NEW HEAT PUMP OVERHANG LINE (N) CO (E) ELECTRICAL OVERHEAD SERVICE LINE STEP (N) GAS METER 5'-23 4" EXISTING SETBACK LINE CO = CLEANOUT DS = DOWNSPOUT LEGEND 8" SWEET GUM TREE TO REMAIN 10 ' - 1 1 12" NEW HEAT PUMP ADU OVERHANG LINE 3'-23 4" 3'-8" NEW HEAT PUMP 20 ' 6' - 1 14" 3'-9" 3'-9"3'-21 4" H.B. STEP AREA OF IMPERVIOUS SURFACES = 576 SQ.FT. AREA OF FRONT YARD = 1,200 SQ.FT. RATIO = 576/ 1,141= 49.1%