HomeMy WebLinkAboutRM-2025-011 - A1 Site PlansEXISTING SITE PLAN
SCALE 1 8"= 1'-0"
1
P1 APRIL 28, 2025
A1
VA
N
D
E
R
H
A
E
G
E
N
-
W
A
N
R
E
S
I
D
E
N
C
E
76
4
1
P
E
A
C
H
B
L
O
S
S
O
M
D
R
I
V
E
,
C
U
P
E
R
T
I
O
N
O
,
C
A
9
5
0
1
4
CO
R
N
E
L
I
A
H
A
B
E
R
RE
S
I
D
E
N
T
I
A
L
D
E
S
I
G
N
PH
O
N
E
6
5
0
7
8
7
1
1
9
7
co
r
n
e
l
i
a
.
h
a
b
e
r
@
g
m
a
i
l
.
c
o
m
DATE
REVISIONS
Cornelia Haber
PROPOSED SITE PLAN
SCALE 1 8"= 1'-0"
2
mARCH 18, 2025
P2 AUGUST 25, 2025
FRONT YARD IMPERVIOUS SURFACE CALCULATION
EXTERIOR LIGHTING SPECIFICATIONS
P3 OCTOBER 28, 2025
P3
(E) GAS
LINE V.I.F.
(E) SEWER
LINE V.I.F.
(e) water
meter
(E) WATER
LINE V.I.F.
(E) GAS
METER
(e) ELECTRIC
METER
property line 60'
property line 60'
pr
o
p
e
r
t
y
l
i
n
e
1
0
0
'
MINIMUM
SETBACK LINE
FRONT
SETBACK
LINE
REAR
SETBACK
LINE
MINIMUM
SETBACK
LINE
5'
5'
(E)
LANDSCAPING
TO REMAIN
℄
EXISTING
FIRST
FLOOR
EXISTING
GARAGE
(E) DRIVEWAY
OVERHANG
LINE
20
'
20
'
EXISTING
SECOND FLOOR
5'
P.
S
.
E
.
W.
C
.
E
.
24
'
-
9
"
5'
5'-8"
EXISTING
NON-CONFORMING
SETBACK LINE
REQUIRED
SETBACK LINE 9'-91 4"
PEACH BLOSSOM DRIVE
30
'
CURB & GUTTER
EDGE OF PAVEMENT
SIDEWALK
(e) ELECTRICAL
POLE AND
JUNCTION BOX
30" ASH
TREE TO BE
REMOVED
15" FRUIT
TREE TO BE
REMOVED
15" MAPLE
TREE TO
REMAIN
15" MAPLE
TREE TO BE
REMOVED
18" MAPLE
TREE TO BE
REMOVED
15" PALM
TREE TO
REMAIN
EXISTING
PORCH
OVERHANG
LINE
5'-23 4"
EXISTING
SETBACK
LINE
8" SWEET
GUM TREE
TO REMAIN
ADU
OVERHANG
LINE
(E) GAS
LINE V.I.F.
(E) SEWER
LINE V.I.F.
(e) water
meter
(E) WATER
LINE V.I.F.
(e) ELECTRIC
METER
property line 60'
property line 60'
pr
o
p
e
r
t
y
l
i
n
e
1
0
0
'
MINIMUM
SETBACK LINE
FRONT
SETBACK
LINE
REAR
SETBACK
LINE
MINIMUM
SETBACK
LINE
5'
5'
(E)
LANDSCAPING
TO REMAIN
℄
EXISTING
FIRST
FLOOR
EXISTING
GARAGE
(E) DRIVEWAY
(E) CO
OVERHANG
LINE
20
'
20
'
EXISTING
SECOND FLOOR
404.9 SQ.FT.
PORCH
40.3 SQ.FT.
5'
P.
S
.
E
.
W.
C
.
E
.
24
'
-
9
"
LANDING
LANDING
5'
5'-8"
EXISTING
NON-CONFORMING
SETBACK LINE
REQUIRED
SETBACK LINE 9'-91 4"
PEACH BLOSSOM DRIVE
30
'
CURB & GUTTER
EDGE OF PAVEMENT
SIDEWALK
ADU
ADDITION
ADDITION
5%
5%
5%
5%
5%
5%5%
5%
(e) ELECTRICAL
POLE AND
JUNCTION BOX
15" MAPLE
TREE TO
REMAIN
15" PALM
TREE TO
REMAIN
DS
DS
DS
DS
DS
DS
DS
NEW HEAT
PUMP
OVERHANG
LINE
(N)
CO
(E) ELECTRICAL
OVERHEAD
SERVICE LINE
STEP
(N) GAS
METER
5'-23 4"
EXISTING
SETBACK
LINE
CO = CLEANOUT
DS = DOWNSPOUT
LEGEND
8" SWEET
GUM TREE
TO REMAIN
10
'
-
1
1
12"
NEW HEAT
PUMP
ADU
OVERHANG
LINE
3'-23 4"
3'-8"
NEW HEAT
PUMP
20
'
6'
-
1
14"
3'-9"
3'-9"3'-21 4"
H.B.
STEP
AREA OF IMPERVIOUS SURFACES = 576 SQ.FT.
AREA OF FRONT YARD = 1,200 SQ.FT.
RATIO = 576/ 1,141= 49.1%