Loading...
HomeMy WebLinkAboutG1.0 Site Plan, ProposedDN No r t h PL 8 0 . 5 0 ' PL 109.00' ALCALDE RD 8'-11" 1ST LVL SIDE SB 8'-11" 1ST LVL SIDE SB FR O N T S . B . 20 ' - 0 " RE A R S . B . 10 ' - 0 " 1 S T L V L PL 58.50' PL 50.50'PL 4 . 5 0 ' PL 7 6 . 0 0 ' RI G H T O F W A Y 30 ' - 0 " 1 INGRESS & EGRESS EASEMENT 20'-0"11'-11" 2ND LVL SIDE SB RE A R S B 15 ' - 2 1 / 2 " 2 N D L V L 11'-11" 2ND LVL SIDE SB 2 5 4 36 2 20'-0" W 7 8 10'-0"10'-0" 20 ' - 0 " 9 9 DUPLEX -UNIT1 (1,702 SF) W/ GARAGE (442 SF) DUPLEX -UNIT2 (1,397 SF) W/ GARAGE (228 SF) 3'-0" 20'-0" 10 11 3'-0"E2 E1 AC2 AC1 G2 12 23'-0" 22 ' - 7 " W.P. TO P.L. 8'-11" W. P . T O P . L . 20 ' - 4 " NARROWEST W.P. TO NEARST P.L. 29'-7" NA R R O W E S T W . P . T O N E A R E S T P . L . 20 ' - 0 " NEW STREET TREE WITHIN THE PUBLIC RIGHT OF WAY TO BE PLANTED BY THE CITY 3 6'-6" 4' - 6 " CU R B F A C E T O S T . C E N T E R 20 ' - 0 " 10 ' - 0 " 5' - 0 " 2' - 1 " 6'-8" 18'-0" 6'-8"6'-8" 20'-0" PL 8 0 . 5 0 ' PL 109.00' PL PL 50.50'PL 4. 5 0 ' PL 7 6 . 0 0 ' 1,027 SF10 ' - 0 " 20 ' - 0 " 89'-0" 903 SF405 SF 67 SF 404 SF AC1 G2 W E1 SITE PLAN, LEGEND, PROPOSED: PROPERTY LINE BUILDING FOOTPRINT SETBACK CENTERLINE NOTES 1. CONTRACTOR SHALL FIELD VERIFY LOCATIONS OF UTILITIES, SITE CONDITIONS, DIMENSIONS, STRUCTURES PRIOR TO START OF WORK. IN EVENT OF ANY DISCREPANCIES OR POTENTIAL CONFLICTS, NOTIFY THE ARCHITECT IN WRITING PRIOR TO STARTING EACH PORTION OF THE WORK. 2. ALL ELEMENTS IN GREY ARE EXISTING, ALL ELEMENTS IN BLACK ARE PROPOSED. 3. FINISH GRADE AROUND THE STRUCTURE SHALL SLOPE AWAY FROM THE FOUNDATION AT A MINIMUM OF 5% FOR AT LEAST 10 FEET FROM THE STRUCTURE. CBC 1804.4 4. UNDERGROUND ALL OVERHEAD SERVICES FROM DUPLEX TO NEAREST POLE. CONTACT PGE TO INITIATE DESIGN 5. SEPERATE SEWER / GAS / ELECTRICAL LINES FOR DUPLEX U (P) DUPLEX 1ST UNIT AC CONDENSOR EXTERIOR UNIT (P) DUPLEX 2ND UNIT AC CONDENSOR EXTERIOR UNIT AC1 & AC2 SEE SPECIFICATION BOOK . SMARTCOMFERT R4A5S24AKAWA (P) DUPLEX 2ND UNIT GAS METER 3/4" (P) DUPLEX 1ST UNIT 200 AMP MAIN ELECTRICAL PANEL, DUAL SOCKET METER WITH ADU 100 AMP SUBPENAL (P) DUPLEX 2ND UNIT 200 AMP ELECTRICAL PANEL SITE PLAN, PROPOSED, KEYNOTES REAR MINIMUM SETBACK MAY BE REDUCED TO 10 FEET PROVIDED THAT THE REQUIRED REAR-YARD SETBACK AREA IS NO LESS THAN EIGHT HUNDRED FIFTY SQUARE FEET OR TWENTY TIMES OF THE LOT WIDTH. PER. CMC. 19.32.060 SEE FRONT & REAR SETBACK EXHIBIT PROPOSED REAR YARD 1027 SF > 800 SF 1 2 3 4 SIDEWALK, PER ENCROACHMENT PERMIT CURBS, PER CITY OF CUPERTINO STANDARD DETAILS. 1-16 GUTTER, PER CITY OF CUPERTINO STANDARD DETAILS. 1-19 (P) NEW CONCRETE DRIVEWAY, PER CITY OF CUPERTINO STANDARD DETAILS. 1-16, 1-19, 1-21, SEE G1.2 (P) 5' PUE DEDICATED RIGHT-OF-WAY (P) NEW FENCE UNCOVERED PARKING SPACE. PER ORIENTATION OF PARKED VEHICLES. I. ALL VEHICLES PARKED IN THE FRONT OR STREET YARD SETBACK AREA MUST BE PARKED PERPENDITULAR TO THE STREET. SECTBACK LINE FOR 1ST FLOOR SETBACK LINE FOR 2ND FLOOR WALL MOUNT OUTDOOR DOWN LIGHT, MOTION SENSING SEE SPECIFICATION BOOK . C CATTLEYA CA1927-W 5 6 (E) WATER METER (E) UTILITY POLE (DATA) 7 AC2 E2 8 9 LAND USE ZONES PARKING RATIO STALL DIM. (P) 3 ENCLOSED PARKING + 3 OPEN PARKING FOR DUPLEX (2 DWELLING UNITS) DUPLEX R-2 6/2 DUWELLING UNITS (1 ½ ENCLOSED + 1 ½ OPEN) 10 X 20 EA. 10 11 GRASS MULCH PAVER FOR LANDING & WALKWAY EASEMENT CONCRETE FOR SIDEWALK CLAY TILE ROOF 13 PER CMC TABLE 19.124.030A(E). FRONT YARD IMPERVIOUS AREA LIMITATION. (I) LOTS > 60 FEET IN WIDTH, MAXIMUM IMPERVIOUS AREA = 40% OF FRONT YARD AREA. SEE FRONT YARD IMPERVIOUS AREA CALCUALTION TABLE AND FRONT & REAR SETBACK EXHIBIT /2 G1.0 /2 G1.0 12 ATTS LACEFOI LICENSED ARCHITECT FORNIA GORD KONW GNO RENEWAL 03/01/2013 40453-C Ne w C o n s t r u c t i o n D u p l e x 22 6 2 0 - 2 2 6 3 0 A l c a l d e R o a d C U P E R T I N O , C A 9 5 0 1 4 SCALE AS INDICATED R E S I D E N T I A L / C O M M E R C I A L GO R D O N K W O N G , A R C H I T E C T 71 0 E M C G L I N C Y L A N E S U I T E 1 0 9 CA M P B E L L , C A 9 5 0 0 8 (4 0 8 ) 7 9 6 - 1 8 4 5 L I C # 3 4 0 4 5 GK W A r c h i t e c t s . c o m JE N N Y C W O N G PE I L I I N C A O & D E R E K M A N L E Y PR O J E C T R E P R E S E N T A T I V E S 71 0 E M C G L I N C Y L A N E S U I T E 1 0 9 CA M P B E L L , C A 9 5 0 0 8 (4 0 8 ) 7 9 6 - 1 8 4 5 RENEWAL 08/31/2025 12/22/2025 4:44:02 PM G1.0 General, Info & Site Plan, Proposed Ge n e r a l , I n f o & S i t e P l a n , P r o p o s e d SCOPE OF WORK VICINITY MAP 3D MODEL PROJECT DIRECTORY PROJECT INFORMATION PROJECT LOCATION:22620-22630 ALCALDE RD, CUPERTINO, CA 95014 APN:342-16-102 ZONING:TWO FAMILY RESIDENTIAL: R2-4.25 LOT SIZE:8,511 SF / 0.19 ACRES OCCUPANCY TYPE:R3 CONSTRUCTION TYPE:V-B, SPRINKLERED PRIMARY RESIDENCE SET BACKS: MAX. LOT COVERAGE:40% OF NET LOT AREA (EXCLUDE EASEMENT) 40% x 6,901 SF = 2,760.40 PROPOSED LOT COVERAGE:39.97% = 2758 SF / 6,901 SF MAX. STORIES/ HEIGHT:2 STORIES / 30'-0" MAX.RESIDENTIAL UNITS ALLOWED:2 1ST FLOOR SETBACK: PER CMC.TABLE 19.32.060 FRONT: 20'-0" SIDE (INTERIOR): 17'-9.5" (COMBINED)= 0.2 X 89 FT, 20% OF LOT WIDTH MEASURED AT FRONT SB LINE REAR: 10'-0" (REQUIRED REAR-YARD SETBACK AREA IS NO LESS THAN 850 SF) 2ND STORY SECTBACK FRONT 20'-0" SIDE 20'-9.5"(COMBINED), AT LEAST 3'-0" MORE THAN FIRST FLOOR SETBACK REAR 15' 2 1/2'' (20% OF LOT DEPTH = 76 FT x 0.2) FLOOR AREA BREAKDOWN (E) RESIDENCE: 1ST FLOOR 1,865 SF DETACHED GARAGE: 422 SF TOTAL, HABITABLE: 1,865 SF TOTAL,GROSS: 2,287 SF (P) RESIDENCE: 1ST UNIT LEVEL 1 527 SF LEVEL 2 733 SF GARAGE 442 SF TOTAL HABITABLE 1,260 SF TOTAL GROSS 1,701 SF 2ND UNIT LEVEL 1 479 SF LEVEL 2 690 SF GARAGE 228 SF TOTAL HABITABLE 1,169 SF TOTAL GROSS 1,398 SF LOT COVERAGE: 1,740 SF / 6,901 SF = 24.8% < 40% {OKAY} UNITS DIFFERENCE RATIO 1701 SF - 1398 SF = 303 SF (1701 SF + 1398 SF) / 2 = 1,549.5 SF 307 / 1,549.5 = 19.6% < 20% {OKAY} PARKING REQUIRED 6 PARKING SPACES FOR 2 UNITS (1.5 ENCLOSED AND 1.5 OPEN FOR EACH UNIT) PROPOSED 6 PARKING (3 ENCLOSED + 3 OPEN) JURISDICTION CITY OF CUPERTINO DEPARTMENT OF PLANNING AND DEVELOPMENT DUPLEX RESIDENTIAL NEW CONSTRUCTION 3,099 SF • 1ST PRIMARY UNIT 1,702 SF • 3 BED 2.5 BATH • KITCHEN & DINING • FAMILY ROOM • LAUNDRY • GARAGE 442 SF OWNER:CHI TAT LAW & WANCHI SO 22620 ALCALDE RD, CUPERTINO, CA 95014 ARCHITECT:GKW ARCHITECTS INC. | 710 E. MCGLINCY LN. STE 109, CAMPBELL CA 95008 408-315-2125 | GORDONKWONG@GKWARCHITECTS.COM GEOTECHNICAL ENGINEERING: GEOENGINEERING CONS, INC. | 2603 CAMINO RAMON, STE 200, SAN RAMON CA 94583 925-321-5550 | KAMRAN@GEOENGINEERINGCONSULTANTS.COM STRUCTURAL ENGINEER:4X ENGINEERING, INC. | 1885 MERIDIAN AVE, SAN JOSE CA 95125 408-642-5464 | CONTACT@4XENGINEERING.COM LAND SURVEYOR:ROBERT C. LAND SURVEYOR | 966 ELISIE MAE DR., BOULDER CREEK CA 95006 831-359-1750 | ROBERTJAMESCRAIG@GMAIL.COM T24 ENERGY REPORT:CARSTAIRS ENERGY, INC. | 2238 BAYVIEW HEIGHTS DR, SUITE E, LOS OSOS, CA 93402 805.904.9048 | WWW.CARSTAIRSENERGY.COM JURISDICTION:CITY OF CUPERTINO | 10300 TORRE AVENUE, CUPERTINO CA 95014 408-777-3228 | BUILDINGINSPECTORS@CUPERTINO.GOV SANITATION:CUPERTINO SANIT. DIST. | 20863 STEVENS CREEK BLD, STE 100, CUPERTINO CA 95014 408-253-7071 | INFO@CUPERTINOSANITARYDISTRICT.ORG HERS FEATURE SUMMARY ALCALDE RD PALM AVE LO C K W O O D D R PROJECT LOCATION SANTA PAULA AVE SA N T A L U C I A R D ME R R Y M A N R D S F O O T H I L L B L V D SA N L E A N D R O A V E MERRYMAN RD ALICIA CT COR D O V A R D MERC E D E S R D SAN F E L I P E R D 1" = 10'-0"1 Site Plan, Proposed 1/64" = 1'-0"2 Front & Rear Setback Exhibit ALCALDE DUPLEX C A L I F O R N I AC U P E R T I N O APPLICABLE CODES • 2022 CALIFORNIA BUILDING CODE • 2022 CALIFORNIA RESIDENTIAL CODE • 2022 CALIFORNIA MECHANICAL CODE • 2022 CALIFORNIA PLUMBING CODE • 2022 CALIFORNIA ELECTRICAL CODE • 2ND PRIMARY UNIT 1,397 SF • 3 BED 2.5 BATH • KITCHEN & DINING • LAUNDRY • GARAGE 228 SF • 2022 CALIFORNIA ENERGY CODE • 2022 CALIFORNIA FIRE CODE • 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE • CITY OF CUPERTINO MUNICIPAL CODE • ALL OTHER STATE AND LOCAL LAWS, ORDINANCES & REG. • FIRE SPRINKLERS ARE REQUIRED. SEPARATE SYSTEM FOR 2 UNITS. NO PENETRATION THROUGH FIRE RATED WALL APPROVED AUTOMATIC SPRINKLER SYSTEMS IN NEW AND EXISTING BUILDINGS AND STRUCTURES SHALL BE PROVIDED IN THE LOCATIONS DESCRIBED IN THIS SECTION OR IN SECTIONS 903.2.1 THROUGH 903.2.12 WHICHEVER IS THE MORE RESTRICTIVE AND SECTIONS 903.2.14 THROUGH 903.2.21. FOR THE PURPOSES OF THIS SECTION, FIREWALLS AND FIRE BARRIERS USED TO SEPARATE BUILDING AREAS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CALIFORNIA BUILDING CODE AND SHALL BE WITHOUT OPENINGS OR PENETRATIONS. • STANDARD PV SYSTEM - TBD • TBD DEFERRED SUBMITTALS 0'5'10'20'40' FRONT YARD IMPERVIOUS AREA CALCULATION TABLE IMPERVIOUS TYP.PERVIOUS TYP. CONCRETE GRASSMULCHPAVERS MATERIAL TYP. AREA / SQFT TOTAL FRONT YARD / SQFT 405 90340467 Revision Schedule 1 2025.07.30 DUPLEX - PLNG 2 2025.09.22 DUPLEX - PLNG 3 2025.10.22 DUPLEX - PLNG 2,180 IMPERVIOUS %472 / 2,180 = 21.65% < 40% {OKAY} 3 Sheet Index Sheet Number Sheet Name General G1.0 General, Info & Site Plan, Proposed G1.1 General, Notes & Site Plan, Existing G1.2 General, Driveway Details & Flow Data G1.3 General, Privacy Plan Land Survey LS1.0 Land Survey, Boundary Map Architectural A1.0 Architectural, 1st Floor Plans, Proposed A1.1 Architectural, 2nd Floor Plans, Proposed A1.2 Architectural, Floor Area, Roof Plans, Proposed A2.0 Architectural, Elevations, Proposed A3.0 Architectural, Sections, Proposed A4.0 Architectural, Window & Door Schedule, Proposed A5.0 Architectural, Building Details A5.1 Architectural, Fire Rating, Details A6.0 Architectural, 3D & Enlarged Views MEP E1.0 Architectural, Electrical & Lighting Plan, Proposed M1.0 Architectural, Mechanical & Plumbing Plan, Proposed 3