HomeMy WebLinkAboutRM-2025-009 - A-1 Site PlanABBREVIATIONS
POUND OR NUMBER
GALV
GALVANIZED
&
AND
GWB
GYPSUM WALL BOARD
AT
HI
HIGH
AD
AREA DRAIN
HP
HIGH POINT
AFF
ABOVE FINISHED FLOOR
HR
HOUR
ALUM
ALUMINUM
HVAC
HEATING, VENTILATING, AND AIR CONDITIONING
BD
BUILDING DEPARTMENT
INSUL
INSULATED OR INSULATION
BSMT
BASEMENT
INT
INTERIOR
BYND
BEYOND
LO
LOW
DOT
BOTTOM
MAX
MAXIMUM
GHNL
CHANNEL
MECH
MECHANICAL
CJ
CONTROL JOINT
MEMBR
MEMBRANE
GLG
CEILING
MIN
MINIMUM
CLR
CLEAR
MIL
METAL
CMU
CONCRETE MASONRY UNIT
OC
ON CENTER
COL
COLUMN
PCC
PRE -CAST CONCRETE
CONC
CONCRETE
PD
PLANNING DEPARTMENT
CONT
CONTINUOUS
PLUMB
PLUMBING
DBL
DOUBLE
PLYD
PLYWOOD
DEMO
DEMOLISH OR DEMOLITION
PT
PRESSURE TREATED
DIA
DIAMETER
PVC
POLYVINYL CHLORIDE
DIM
DIMENSION
REDD
REQUIRED
ON
DOWN
RM
ROOM
SIN
SIMILAR
DR
DOOR
SPEC
SPECIFIED OR SPECIFICATION
DWG
DRAWING
SPK
SPRINKLER OR SPEAKER
EA
EACH
SSTL
STAINLESS STEEL
EJ
EXPANSION JOINT
SIC
SOUND TRANSMISSION COEFFICIENT
EL
ELEVATION
STL
STEEL
ELEC
ELECTRICAL
S
STRUCTURE OR STRUCTURAL
ELEV
ELEVATOR OR ELEVATION
T&G
TOONGGUEUE AND GROOVE
EQ
EQUAL
TELE
TELEPHONE
EXIST
EXISTING
TLT
TOILET
EXP JT
EXPANSION JOINT
TO
TOP OF
EXT
EXTERIOR
TOP
TOP OF PLATE
FD
FLOOR DRAIN OR FIRE DEPARTMENT
TYP
TYPICAL
FEC
FIRE EXTINGUISHER CABINET
UNO
UNLESS NOTED OTHERWISE
FIXT
FIXTURE
VIP
VERIFY IN FIELD
FEB
FLOOR
Wl
WITH
FND
FOUNDATION
WD
WOOD
GA
GAUGE
NOTES, 1) CONGRI=TE-ENGAGED 6ROUNDIN6 5+4N.. COMPLY M ►EG,
SEC. 25O 6 OTHER APFUGA5L.E CO2) 6ROUNDW6 GLAt4• 5 5NN..I.
ee LISTL-'D FOR THE MATTRlALS ON` THE 6ROUNDIN& ELEGTROL'JE • THE
6RO. VIN& ELECTRODE CONDUCTOR 6 N1 USED ON PIPE, ROD OR
OTHER BURIED ELECTRODES SHALL BE LISTED FOR DIRECT SOIL e1JPJAL;
5) NOT P4 RE TNVW ONE CONDUCTOR SHALL BE GONIGGTgD TO THE
6RO JlvIN6 ELECTRODE 8Y A SD46Le GLANF OR FITTR* UN&E56 TNe
GLAFP OR Frrn & 19 L15TEP FOR MIA.TIPLE CONIDUGTORS, 4.) 6ROUtDII-
GLAA#•9 SHALL COMPLY PITH NEC, SEC. 250-115.
6ROUNlDIN6 ELECTRODE
GON62UCTOR DOES NOT 1:- HAVE TO eE LARbL-it
THAN '4 COPPER
6ROUNIO N& ELECTRODE f1'EC, SSEC' . 27O-44.
GON4DUGTOR EX NOB. 16 2 Ib))
E 6ROMIDiN6
6Rr6 AlMDRELECTRODE GL AF4• DEVICE
�• NIO*E'TALIC
CONCRETE FO,R4DATI'ON
n n a
$4 At+tb OR LAR6E7t
C-� DAM COPPER
N _ ,_ GO UX.TOR OR
DIRECT 111F' III �II1 =�I jf I 11 t=ltlt= ST®. AlEn4FORGlt4Ci
CONTAG7 I( _ if 7� Ill llifii ll i% �, t ;((>1= Ir" SIAM OR ROD Vii
PV MARTfa i.e THAN 112• DIA.
.2O' -O' MIN,
SGAI.L: 9/4 a r-0
7 GONC.RET! ENCASED 6VUNDIN& ROD
SANITARY DISTRICT
1. INSTALL NEW PROPERTY LINE CLEANOUT TO DISTRICT'S STANDARDS. SEE ATTACHED DETAIL. PROPERTY
LINECLEANOUT MUST BE WITHIN 5 FEET OF THE PROPERTY LINE. CLEANOUT SHALL BE THE SAME DIAMETER
AS THE STREET PORTION OF THE SERVICE LATERAL. GRAVITY LATERAL IS 4" DIAMETER. (O.C. 4101)
2. EXISTING SANITARY SEWER LATERAL SHALL BE DISCONNECTED AND CAPPED IN THE PRESENCE OF A
DISTRICT INSPECTOR. OWNER TO CALL THE DISTRICT AT LEAST 48 HOURS PRIOR TO WORK TO SCHEDULE
AND DISTRICTINSPECTOR. (O.C. 5203)
3. CUPERTINO SANITARY DISTRICT INITIAL (VISUAL) INSPECTION REQUIRED. CONTRACTOR SHALL LEAVE NEW
PIPE INSTALLATION EXPOSED. DO NOT BACKFILL. OWNER TO CONTACT DISTRICT 48 HOURS PRIOR TO
SCHEDULING A DISTRICT INSPECTOR FOR A VISUAL INSPECTION. (O.C. 5203)
4. CUPERTINO SANITARY DISTRICT FINAL (CCTV) INSPECTION AND APPROVAL OF THE NEW PROPERTY LINE
CLEANOUT, POINT OF CONNECTION, AND DISTRICT LATERAL IS REQUIRED PRIOR TO CLEARANCE FOR CITY OF
CUPERTINO FINAL INSPECTION. OWNER MUST ALLOW DISTRICT AT LEAST 48 HOURS' NOTICE TO SCHEDULE A
DISTRICT INSPECTOR FOR A VIDEO INSPECTION. DISTRICT TO PROVIDE BUILDING DEPARTMENT WITH
WRITTEN NOTIFICATION UPON COMPLETION OF INSPECTION. (O.C. 7102)
5. STORM WATER SURFACE OR ROOF DRAINS AND OTHER GENERAL SURFACE WATER RUNOFF, SHALL NOT BE
DISCHARGED TO THE SANITARY SEWER.
6. THE CUPERTINO SANITARY DISTRICT RECOMMENDS INSTALLING THE REQUIRED IMPROVEMENTS NEAR THE
BEGINNING OF THE PROJECT IN CASE ANY UNFORESEEN ISSUES ARISE WITH THE INSTALLATIONS.
7. THE APPLICANT MAY POTENTIALLY BE REQUIRED TO UPGRADE THEIR SANITARY SEWER LOWER LATERAL IF
THE DISTRICT FINDS THE STRUCTURAL CONDITIONS OF THE PIPE TO BE UNSATISFACTORY.
8. PROPERTY WILL BE PLACED ON NEXT FISCAL YEAR'S SANTA CLARA COUNTY PROPERTY TAXES FOR
DISTRICT'S SEWER SERVICE FEES.
• Storm water surface or roof drains and other general surface water runoff shall not be
discharged to the sanitary sewer
-
• The Cupertino Sanitary District recommends installing the required improvements near
the beginning of the project in case any unforeseen issues arise with the installations-
• The applicant may potentially be required to upgrade their sanitary sewer lower lateral if
the District finds the structural conditions of the pipe to be unsatisfactory.
EXT. OUTDOOR LIGHT
LIGHTING FEATURES: DARK SKY (CUPERTINO MUNICIPAL CODE SECTION
'FEIT ELECTRIC' 50 -WATT EQUIVALENT LED LIGHT BULB 19.102.040 OUTDOOR LIGHTING REQUIREMENTS)
PAR20 SHAPE LIGHT BULB WITH MEDIUM (E26) BASE OUTDOOR LIGHTING MUST BE FULLY SHIELDED
IDEAL FOR RECESS AND TRACK LIGHTING APPLICATIONS FIXTURES, DIRECTED DOWNWARD TO MEET PARTICULAR
FULL RANGE DIMMING WITH EVEN LIGHT DISTRIBUTION NEED AWAY FROM ADJACENT PROPERTIES AND
BRIGHTNESS: 450 LUMENS RIGHTS -OF -WAYS TO AVOID LIGHT TRESPASS.
LIGHT APPEARANCE: 3000K (BRIGHT WHITE) MAXIMUM LIGHT INTENSITY ON A SITE SHALL NOT
INPUT LINE VOLTAGE: 120 -VOLT EXCEED A MAINTAINED VALUE OF TEN FOOT-CANDLES,
CA ENERGY COMMISSION (CEC) TITLE 20 & TITLE 24 COMPLIANT WHEN MEASURED AT FINISHED GRADE.
ALL LIGHT SOURCES SHALL HAVE A MAINTAINED
CORRELATED COLOR TEMPERATURE OF 3,000 KELVIN OR
LESS.
ALL OUTDOOR LIGHTING MUST BE FULLY EXTINGUISHED
OR BE MOTION SENSOR OPERATED BY 11:00 P.M. OR
WHEN PEOPLE ARE NO LONGER PRESENT IN EXTERIOR
AREAS, WITH EXCEPTIONS.
LIGHTING DESIGN STANDARDS SUCH AS LIGHTING
FIXTURES MUST BE OF A DESIGN THAT COMPLEMENTS
THE BUILDING AND LANDSCAPE DESIGN.
PROHIBITED LIGHTING INCLUDES OUTDOOR BLINKING,
FLASHING, OR ROTATING LIGHTS, FLOOD LIGHTS,
SPOTLIGHTS, AND OTHERS AS APPLICABLE.
FINISH LAM PING
Coastal Oil Rubbed Bronze -14 Incandescent
Coastal Natural Iron- 20
Coastal Bronze -75
Coastal Dark Smoke • 77
Coastal Burnished Steel - 78
Coastal Black - 80
SPECIFICATIONS
Henry Large Dark Sky Friendly Outdoor Sconce
Socket Lamping
Base Item #- 302713
Socket= Medium
Configured Item #: 3D2713-1 004
Bulb Par2D (wet location), SOW Max
302713-SKT-75
Number of Bulbs: H (notinduded)
IES Files Available V
Aluminum directwire exteriorgooseneck wall sconce Wthfinish options. Includes a
bulb shieldwhlch focusesthe light downwards- Designed and builtto Dark Sky
Lo,etion Rating
standards-
CL/door Wet
• Handcrafted to order by skilled artisans i n Vermont, USA
• Lifetime Limited Warranty when installed in residential setting
Safety Rating
UL, CULlisted
• Feature our robust Coastal Outdoor finish specifically formulated to resist
some of the harshest environmental conditions.
Dime risiona
Height 12.90"
Width 1440"
Projection 15.80"
Product Weight 2.20 lbs
Backplate 550' x 4-90"
Vertical Mounting Height 480'
Packed Weight 8.00 lbs
Shipping (DIM) Weight 51-00 Ibs
PLANNING NOTES
1. PROJECT CONSTRUCTION ACTIVITIES WILLCONFORM TO THE APPLICABLE REQUIREMENTS OF CITY CODE CHAPTER 17.04.
2. NOTE: ANY CHANGES TO THE APPROVED COLORS, MATERIALS, AND EXTERIOR FINISHES SHALL BE REVIEWED AND
APPROVED BY THE CITY OF CUPERTINO PLANNING DIVISION PRIOR TO INSTALLATION/APPLICATION.
SITE PLAN NOTES
A. GENERAL:
• SEE OWNER FOR UP -GRADE HARDSCAPE FINISH FOR DRIVEWAY, WALKWAY & PATIO
• ALL METAL ANCHORS, FASTENERS, CONNECTORS, ETC. THAT WILL BE IN CONTACT WITH PRESSURE TREATED
LUMBER MUST BE HOT -DIPPED GALVANIZED OR OTHER APPROVED CORROSION RESISTANT MATERIAL.
B. BUILDING SETBACK:
1. CONTRACTOR TO VERIFIED BUILDING SETBACK AND ADJUST WALL TO MEET MINIMUM SETBACK.
2. PRIOR TO FOUNDATION INSPECTION BY THE CITY, THE LICENSED LAND SURVEYOR OF RECORD SHALL PROVIDE A
WRITTEN CERTIFICATION THAT ALL BUILDING SETBACKS COMPLY WITH THE APPROVED PLANS. WHICH NOTE SHALL
REPRESENT A CONDITION WHICH MUST BE SATISFIED TO REMAIN IN COMPLIANCE WITH THIS DESIGN REVIEW APPROVAL.
C. GRADING & DRAINAGE: SEE CIVIL ENGINEER PLAN.
1. ARROWS INDICATE DIRECTION OF SURFACE DRAINAGE.
2. GROUND IS TO SLOPE AWAY FROM FOUNDATION 5% FOR A DISTANCE OF 10 FT AWAY FROM THE BUILDING; IF 10 FT.
CANNOT BE MEET, PROVIDE SWALES. PROVIDE 2% SLOPE IF IMPERVIOUS SURFACE IS USED. CRC R401.3. NO
CONCENTRATED FLOW ACROSS THE RIGHT-OF-WAY. NO DRAINAGE ONTO NEIGHBORING PROPERTIES. ALL
DRAINAGE TO LANDSCAPE.
3. DIRECT ROOF RUNOFF SHALL BE:
• DIRECT ROOF RUNOFF ONTO VEGETATED AREAS
• DIRECT RUNOFF FROM SIDEWALKS, WALKWAYS, AND/OR PATIOS ONTO VEGETATED AREAS;
• DIRECT RUNOFF FROM DRIVEWAYS AND/OR UNCOVERED PARKING LOTS ONTO VEGETATED AREAS.
• CONSTRUCT SIDEWALKS, WALKWAYS AND/OR PATIOS WITH PERMEABLE SURFACES
D. UTILITIES:
1. CONTRACTOR TO VERIFY LOCATION OF ALL UTILITIES @ JOB SITE.
2. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH THE INSTALLATION OF FACILITIES BY PG & E, PACIFIC BELL,
& CABLE TV INSTALLATION AS REQUIRED. VALVE BOXES & MANHOLES, & STRUCTURES TO BE SET TO GRADE IN
CONCRETE AFTER PAVING.
F. CONSTRUCTION SITE:
1. CONSTRUCTION SITE SHALL BE ENCLOSED BY 6' OPAQUE FENCE AT ALL TIMES DURING CONSTRUCTION.
2. NO CONSTRUCTION MATERIAL, EQUIPMENT, PORTABLE TOILETS, TRASH CONTAINERS, OR DEBRIS SHALL BE
PLACED IN THE PUBLIC RIGHT-OF-WAY.
3. A TRASH CONTAINER SHALL BE MAINTAINED ON SITE AT ALL TIMES AND DEBRIS ON SITE WHICH COULD OTHERWISE
BLOW AWAY, SHALL BE REGULARLY COLLECTED AND PLACED IN CONTAINER.
4. ALL CONSTRUCTION DEBRIS (WOOD SCRAPS AND OTHER DEBRIS, WHICH CANNOT BLOW AWAY) SHALL BE PILED
WITHIN THE PROPERTY LINES OR THE PROJECT IN A NEAT AND SAFE MANNER.
1 \ NEW ADDITION FOR
SRIDHARAN & KUMAR
RESIDENCE
21969 OAKDELL PL, CUPERTINO, CA 95014
APN# 326-39-003
THIS PROJECT SHALL COMPLY WITH
2022 CALIFORNIA BUILDING CODE
2022 CA RESIDENTIAL CODE
2022 CA PLUMBING CODE
2022 CA MECHANICAL CODE
2022 CA ELECTRICAL CODE
2022 CA FIRE CODE
2022 CA ENERGY CODE
2022 CA GREEN BUILDING CODE
CITY OF CUPERTINO MUNICIPAL CODE
I
— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
�\���� R S89°18'1711E 74.00 WOOD
R� _ off HFENCEoH off
O[ I --
iH -- --
o Lill A JUS CONC. WALL
ADJUST CONC. WALL 1 a J CLEAR FRO
------------------- 1 — CLEAR FROM5'P.U.E. m_ M5 P.U.E.
— — — — — — — — — — — — — — — — — — — — — — — — — — —
ui o <r
q N 1
in
LA W N § 0 25'-6" +T-6"
ANCHOR
EASEMENT' t---------------------------
CONCRETEREAR 1 I�
PATIO YARD SETBACK
AREA: ONx74' = 1 BA S.F. NEW ADDITION 5%
ADDITION IN SETBACK:
9'-8"x25'-6" IRREGULAR 5 WOOD
__
WOOD (E) ELECTRIC TOTAL REAR YARD IN THE 1
FENCELINE PER PG&E 20FT SETBACK: 1,246 S.F. (E)6' 11" 1
LaJ TOTAL REAR YARD NOT IN
THE 20FT SETBACK. 396 S.F. I
1 1
UPGRAD TO
I I
200 AMP
PROVIDE U.F.E.R. ELECTRICAL
GROUND w/ 2 NO. 4 REBARS 20
FT. LONG EMBEDDED IN
FOOTING IN OPPOSITE
DIRECTIONS. SEE DETAIL 1/Al
rIM
NEIGHBOR'S
DRIVEWAY
SIDEWALK
(E) 1 1/2" PVC WATER LINE —'
PER WATER CO. CONTRACTOR
TO VERIFY ON FIELD
I
1 I
1 CONCRE1IE
WALK
8'-0" B.S.L.
1
I
1� I
1 cS
I CON CREITE
1 Di
1
_L.
(E)
c0
(E) 2 CAR GARAGE
EXISTING RESIDENCE
F.F.•104.1
Z�N�ROIDE FIRE SPRINKLER
NEW ADDITION
(N)PORCH
_ _ _ _ (E)RIVER RO KS
TO REMAIN
(E) CONCRETE
WALKWAY
I N
(E) GAS LINE PER PG&E ,h1'\\
1 I (E)BARKS
(N)RIVER II m 7AIN\ROCKSTOCONCRETE MATCH(E)iN
DRIVEWAY REMOVE I
1O II (N)PLCo O=
CONCRETE
DETAIL 7/X2.1
165"
in
R S89°18'17"W 35.27
\(E)12" •
MAGNOLIA
CC
(E)BARKS
TO REMAIN
(E) S.S. LINE PER SANITAR
DISTRICT. VERIFY ON FIELD
(E)RIVER ROCKS
TO REMAIN R� �C •G�1 !�
O :Za J211 LL
1
1
(N)1 % SWALE
1
1
I
I ILr5
C)
1
)
�
1 �
�
T-0" B.S.L.
O
O
O
co
y
I'
±7'-7" i I
5>
C OOH
WALL
19-1" � I ERVIOUS PAVING NORTH
CONT ACTOR SHALL PROTECT 40% FRONT YARD 20FT SETBACK AREA:
PUBLIC WORKS NOTES: EXISTING TREE AND TREE ROOTS 40% (1,508 S.F.) = 603.2 S.F. MAX.
1. THE SITE PLAN IS PREPARED BASED ON THE BOUNDARY SURVEY 1 FROMANY DAMAGE. TREE 1. DRIVEWAY 505 S.F.
PREPARED BY THE PROJECT'S LICENSED SURVEYOR. PROTECTION SHALL BE 2. WALKWAY 71 S.F.
2. IF THE PROJECT DAMAGES THE CITY'S SIDEWALK, DRIVEWAY, OR CURB INSTALLED PER CITY STANDARD TOTAL IMPERVIOUS: 576 S.F. (38.2%)
AND GUTTER AS RESULT OF CONSTRUCTION ACTIVITIES, THE DETAIL 6-4."
PROPERTY OWNER WILL BE RESPONSIBLE TO REMOVE AND REPLACE
ANY BROKEN CONCRETE DIRECTED BY THE PUBLIC (EXISTING WORKS NOR DAMAGES BY THE S ECTOR. AN ENCROACHMENT
AS SITE P LAN
PERMIT WILL ALSO BE REQUIRED." SCALE: 1/8" = 1-0"
CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS
PROJECT DATA
ASSESSOR'S PARCEL #:
326-39-003
PROJECT ADDRESS:
21969 OAKDELL PL, CUPERTINO, CA 95014
PROPERTY OWNER:
SRIHARI SRIDHARAN & NIVETHITHA KUMAR
(408) 799-1203 srihari.apple@gmail.com
21969 OAKDELL PL, CUPERTINO, CA 95014
PROJECT CONTACT PERSON: TRI HONG (408)829-6083 tdhdesign@hotmail.com
19034 BONNET WAY, SARATOGA, CA. 95070
PROJECT SCOPE OF WORK: PROPOSED 2,918 S.F.
FRONT ADDITION (681 SF); REAR ADDITION (319 SF); NEW COVERED PORCH (26 SF);
WHOLE HOUSE REMODEL (1,918 SF) - NEW GREAT ROOM, DINING ROOM REMODEL,
LAUNDRY ROOM REMODEL, NEW HALL BATH ADDITION, EXISTING BEDROOM
REMODELS, BEDROOM 2 BATH ADDITION, NEW MASTER WALK-IN CLOSET, NEW ATTIC
ACCESS, (4) NEW SKYLIGHTS, (9) SUN TUNNELS, BAY WINDOWS, WINDOW AND SLIDING
DOOR REPLACEMENTS; KITCHEN REMODEL (150 SF); EXISTING BATH 2 REMODEL (43
SF); NEW LIGHTS; SWITCHES; OUTLETS; NEW TANKLESS WATER HEATER; NEW HEAT
PUMP AC UNIT; ELECTRIC METER UPGRADE (200A); NEW GARAGE DOOR; FIRE
SPRINKLERS REQ.
EXISTING ZONING:
R1-7.5 GEOLOGIC HAZARD ZONE LIQUEFACTION -INUNDATION.
OCCUPANCY:
R3 -U
TYPE OF CONSTRUCTION:
V -B FULLY-SPRINKLERED INSTALLED PER NFPA 13D 2022
EXISTING USE:
ONE STORY SINGLE FAMILY RESIDENCE
PROPOSED USE:
ONE STORY SINGLE FAMILY RESIDENCE
GROSS LOT SIZE:
7,576 S.F.
NET LOT SIZE:
7,576 S.F.
FLOOR AREA RATIO CALCULATION:
NEW ADDITION:
999.81 S.F.
EXISTING LIVING AREA:
1,918 S.F.
PROPOSED LIVING AREA:
2,917.81 S.F.
EXISTING GARAGE:
439 S.F.
PROPOSED FA.R.:
3,356.81 S.F. (3,409.2 MAX.)
BUILDING COVERAGE CALCULATION:
MAX. COVERAGE: 45% (7,576) + 5%(7,576)= 3,788 S.F.
PROPOSED F.A.R.:
3,356.81 S.F.
NEW COVERED PORCH:
25.66 S.F.
OVERHANGS:
248.6 S.F.
PROPOSED COVERAGE:
3,631.07 S.F. (47.92%)
SET BACK REQUIREMENT
REQUIRED
PROPOSED
SETBACKS 1st floor
1st floor COMPLIANT
FRONT
20'-0" (N)20' -l" YES
LEFT SIDE
8'-0" (E)8'-2" YES
RIGHT SIDE
7'-0" (E)6'-11" NO
REAR
20'-0" (N)10'-4" NO
CONSULTANTS LIST
DESIGNER STRUCTURAL ENGINEER MANUFACTURER CONTACT
TDH DESIGN WESLEY LIU ENGINEERING • 'Gaf Roofing:
19034 BONNET WAY 7246 SHARON DRIVE #O (877) 423-7663 www.gaf.com/
SARATOGA, CA 95070 SAN JOSE, CA 95129 • 'Velux' Skylight:
408.829.6083 408.973.1839 (800) 888-3589 www.veluxusa.com
tdhdesign@hotmail.Com wesleyliu@yahoo.com • 'Grace Construction' Flashing
ENERGY CONSULTANT SURVEY (866) 333-3726 www.gcpat.com
CARSTAIRS ENERGY CALC. DOMINGUEZ ASSOCIATES LLC
904 EVERT COURT 4360 COOPER HOLLOW RD.
PASO ROBLES, CA 93446 DALLAS, OR 97338 1
805.904.9048 650.359.0947
carlos@dominguezassociates.com
timmycarstairs@yahoo.com
GENERAL NOTES
1. ALL WRITTEN DIMENSIONS SHALL OVER TAKE PRECEDENCE OVER SCALED DIMENSIONS.
2. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF TDH DESIGN PRIOR TO COMMENCING.
3. LOCATION OF UTILITIES AND EXISTING CONDITIONS AT SITE TO BE VERIFIED PRIOR TO CONSTRUCTION BIDDING.
4. ALL WORK APPLIANCES AND EQUIPMENT SHALL COMPLY WITH C.E.C TITLE 24 RESIDENTIAL ENERGY STANDARDS.
5. BUILDER/CONTRACTOR:
• RESPONSIBILITY FOR METHOD AND MANNER OF CONSTRUCTION AND FOR ALL JOB SITE
SAFETY DURING CONSTRUCTION.
• SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR METHOD & MANNER OF ALL
WATERPROOFING. BUILDER/CONTRACTOR SHALL REFER TO SOIL REPORT, GRADING &
DRAINAGE PLAN, AND ALL WATERPROOFING WORK TO BE PERFORMED BY NHQ CERTIFIED
WATERPROOFING COMPANY.
• SHALL PROVIDE THE BUILDING OWNER, MANAGER, AND THE ORIGINAL OCCUPANTS A LIST OF
THE ENERGY -SAVING CONSERVATION FEATURES DEVICES, MATERIALS, AND COMPONENTS
INSTALLED IN THE BUILDING, AND INSTRUCTIONS ON HOW TO USE THEM EFFICIENTLY, SUCH
FEATURES INCLUDE HEATING, COOLING, WATER HEATING, AND LIGHTING SYSTEMS, AS WELL
AS INSULATION, WEATHER STRIPPING WINDOW SHADES, AND THERMAL MASS MATERIALS,
THE INSTRUCTIONS SHALL BE CONSISTENT WITH SPECIFICATIONS BUT FORTH BY THE
EXECUTIVE DIRECTOR.
6. STATEMENT OF SPECIAL INSPECTIONS. SPECIAL INSPECTION IS REQUIRED PER §1705 OF 2022 CBC FOR:
1) POST -INSTALLED MECHANICAL, AND ADHESIVE ANCHORS IN HARDENED CONCRETE MEMBERS REQUIRE SPECIAL
INSPECTION PER CORRESPONDING ICC-ES EVALUATION REPORT.
2) STRUCTURAL WOOD PER §1705.12.1 AND §1705.13.2 FOR NAILING, BOLTING, ANCHORING AND OTHER FASTENING OF
ELEMENTS OF THE MAIN WIND FORCE -RESISTING SYSTEM, SEISMIC FORCE -RESISTING SYSTEM, INCLUDING WOOD
SHEAR WALLS, WOOD DIAPHRAGMS, DRAG STRUTS, BRACES, AND HOLD-DOWNS WHERE FASTENER SPACING OF
SHEATHING LESS THAN OR EQUAL 4 INCHES ON CENTER.
3) SOILS PER CBC §1705.6: SPECIAL INSPECTIONS AND TESTS OF EXISTING SITE SOIL CONDITIONS, FILL PLACEMENT
AND LOAD -BEARING REQUIREMENTS SHALL BE PERFORMED IN ACCORDANCE WITH THIS SECTION AND TABLE
1705.6. THE APPROVED GEOTECHNICAL REPORT AND THE CONSTRUCTION DOCUMENTS PREPARED BY THE
REGISTERED DESIGN PROFESSIONALS SHALL BE USED TO DETERMINE COMPLIANCE.
4)A
1HARDY FRAME® PANELS PER §4.4 OF ICC-ES EVALUATION REPORT ESR-2089
5) DEFERRED SUBMITTALS LIST:
1. AUTOMATIC FIRE SPRINKLER SYSTEM UNDER SEPARATE PERMIT.
A. AN OWNER'S MANUAL FOR THE FIRE SPRINKLER SYSTEM SHALL BE PROVIDED TO THE OWNER.
B. A SIGN OR VALVE TAG SHALL BE INSTALLED AT THE MAIN SHUTOFF VALVE TO THE WATER DISTRIBUTION SYSTEM
STATING THE FOLLOWING:
"WARNING, THE WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND
PRESSURES TO FIGHT A FIRE. DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR AUTOMATICALLY
SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM, SUCH AS WATER SOFTENERS, FILTRATION SYSTEMS AND
AUTOMATIC SHUTOFF VALVES, SHALL NOT BE ADDED TO THIS SYSTEM WITHOUT A REVIEW OF THE FIRE SPRINKLER
SYSTEM BY A FIRE PROTECTION SPECIALIST. DO NOT REMOVE THIS SIGN."
C. INSPECTIONS: THE WATER DISTRIBUTION SYSTEM SHALL BE INSPECTED IN ACCORDANCE WITH SECTIONS R313.3.8.1
AND R313.3.8.2.
ACCORDING TO THE 2022 ENERGY CODE SINGLE-FAMILY RESIDENTIAL COMPLIANCE MANUAL, A COPY OF
THE COMPLETED, SIGNED, AND DATED CF2R MUST BE POSTED AT THE BUILDING SITE FOR REVIEW BY
THE ENFORCEMENT AGENCY IN CONJUNCTION WITH REQUESTS FOR FINAL INSPECTION FOR THE
BUILDING. COPIES OF THE REGISTERED CF2R FORMS SHALL BE PROVIDED TO THE HOMEOWNER.
THE CERTIFICATE OF INSTALLATION (Cl IS SEPARATED INTO:
1) ENVELOPE (CF2R-ENV).
2) LIGHTING (CF2R-LTG).
N3) MECHANICAL (CF2R-MPH).
4) PLUMBING (CF2R-PLB).
SHEET INDEX
ARCHITECTURAL STRUCTURAL
/ A-1 SITE PLAN SO - STRUCTURAL NOTES
A-2.1 EXISTING FLOOR PLAN & FLOOR AREA CALC. S1 - FOUNDATION PLAN
/ A-2.2 PROPOSED FLOOR PLAN S2 - STRUCTURAL DETAILS
/ A-3 PROPOSED ELEVATIONS S3 - CEILING FRAMING PLAN
/ A-4 ROOF PLAN & SECTION S4 - ROOF FRAMING PLAN
A-5 DETAILS S5 - STRUCTURAL DETAILS
F-1 TYPICAL FLASHING DETAILS S6 - STRUCTURAL DETAILS
NEIGHBOR'S /
DRIVEWAY
i
7
N /'/
LEGEND
EXISTING FLOOR AREA
NEW ADDITION
1
SWALE SLOPE
DOWN SPOUTS w/ CONCRETE
SPLASH BLOCK LOCATION
E-1
ELECTRICAL PLANS
T24.1
TITLE 24
T242,
TITLE 24
24.3 'TITLE
24
G-1
CALGREEN CHECKLIST
Ni
GENERAL NOTES
CO
SURVEY
BMP
BEST MANAGEMENT PRACTICE
VICINITY
MAP
B Ar S#E
Somerset
��"°
C -.0 erlino
Or
SquarePark
or
1iarlman Jr
a
�i�ytca S t
,f
L� st
�Ga
Stevens Creek
°sxr
are
Elementary School
0, SI
4 a yEenue Dog P
Varian Park oodbury Dr Filzgerald Or
University Way
C
Gi.e
Ave
Sunny View Care Center ��
4
P
m v
L
85
rllno Rd
Blackberry Farm
Golf Course
=ns Creek BIVd
Granada Ave "r°•in 6�
ax
f
a
in
HermosaAveIC a
V
1
Lcmita AvlNORTH
4
L omits Ave
REVISIONS BY
03.09.25 PC#1
z
a
W
OC
o
CD
W
O
z o
zo�Z
O W aM
0Z U
p CV
M
Q O
J Z
W LU Q
z a LU Y
rCD
rn
0
W O
G O
O M Ln
2 00
O co v
D
U o0
CE -
W <
PR
LL 10
O
z
O
m
M
O
0
DRAWN
LOC HUA
CHECKED
TRI HONG
SIGNATURE
W
DATE
OCT. 2O24
SCALE
AS SHOWN
JOB
1724
SHEET
A-1