HomeMy WebLinkAboutBLD-2024-1546_JobCardShear Wall & Diaphragm Report#: 061000-000002 10/17/2025 ACE Inspection Quality Control San Leandro Branch Client: Project: 3075 Teagarden Street San Leandro, CA 94577 Doris Yeh 30-25071T1 Phone: 510.969.4239 10354 Imperial Ave 10354 Imperial Avenue, Cupertino Cupertino, CA 95014 10354 Imperial Ave Cupertino, CA 95014 Site Contact: Emily Contact Title: Superintendent Contractor (s): Modern Edge Builders Agency: City of Cupertino, Permit # BLD - 2024- 1546 Approved Plan Date: 08/06/2025 Ref. Structural Sheet (s): S - 1 Plans Prepared By: Secure Struture Weather: Cloudy Wind (mph): 5 Temperature (F): 64 Delta Revision: Ref. Detail (s): S-1 & S- 2 Shear Wall Materials WSP-wood structural panel type? Plywood WSP-wood structural panel grade thickness? 3/8" WSP-wood structural panel No. of Ply's (3 min)? Pass Verify the nail spacing at the boundaries? Pass Verify the nail spacing Edges? Pass Verify the nail spacing Field? Pass Boundary nails into hold-down posts? Pass Permit No.: Inspection Date: 10/15/2025 Technician: Medhat Gourgui Area (s) Inspected: Structural Wood: Exterior / Structural Wood: Interior Specifications Reviewed: Yes Applicable RFI's: WSP-wood structural panel Span Rating (32/16)? Pass Identify nail type (common nails or galvanized common nails only). SMMC & ASTM F1667? Common Check nail shank diameter ASTM F 1667 Table 5: 8d=21/2"Lx0.131 D Nail Placement Boundary nails into Top Plates? Pass Boundary nails into Collector Lines? Pass Boundary nails into perimeter of Shear Diaphragm? Pass Shear Wall Transfer Fastener size and spacing of shear wall sill plate to floor framing below per plan? Pass Fastener size and spacing of shear wall sole plate to floor framing below per plan? Pass Anchor bolts minimum 4" from ends of sill plates (not more than 12 inches from ends)? Pass Anchor Bolt not less than 1 3/4 inches to (outside) edge of concrete foundation? Not Applicable Verify 3"X3" square plate washers on anchor bolts in shear walls? Not Applicable Hot dipped galvanized fasteners and connectors, including nuts & bolts, in treated wood? Not Applicable Shear Wall Hardware Page 1 of 6 Shear Wall & Diaphragm Report#: 061000-000002 10/17/2025 ACE Inspection Quality control San Leandro Branch 3075 Teagarden Street San Leandro, CA 94577 Phone: 510.969.4239 Client: Doris Yeh 10354 Imperial Ave Cupertino, CA 95014 Project: 30-25071 Ti 10354 Imperial Avenue, Cupertino 10354 Imperial Ave Cupertino, CA 95014 Upload Picture Picture Description f _ Exterior shear wall in . ! Exterior shear wall 4t fr { 5511 f.I Page 3 of 6 Report #: 061000-000002 10/17/2025 ACE Quality Control San Leandro Branch 3075 Teagarden Street San Leandro, CA 94577 Doris Yeh 30-25071T1 Phone: 510.969.4239 10354 Imperial Ave 10354 Imperial Avenue, Cupertino Cupertino, CA 95014 10354 Imperial Ave Cupertino, CA 95014 +►A.. nss,iw.Mc zw�.a+a•.wto» •uaHUf� $Ii norms a; r r ! ~' iKhhds411�`r1.s ,rR nanvk C44now1� ' +nr It .. U Al Shear Wall & Diaphragm Inspection Client: Project: __ KJUNCJ _ Riy • ♦fir •......e+r wnan�w. Attachment Description: Locations of interior and exterior shear walls Upload Attachment: MMtftS lll�`Y) i t+WVAt5 lk44'0 Page 5 of 6