RM-2024-016 - A1.1-site planPUBLIC WORK NOTES: 1. APPROVAL OF THESE PLANS DOES NOT RELEASE THE OWNER AND/OR CONTRACTOR OF THE RESPONSIBILITY OF THE CORRECTIONS OF MISTAKES, ERRORS, OR OMISSIONS CONTAINED THEREIN. IF DURING THE COURSE CONSTRUCTION IMPROVEMENTS, PUBLIC INTEREST REQUIRES A MODIFICATION OF/OR A DEPARTURE FROM THE CITY OF CUPERTINO SPECIFICATION OR THERE IMPROVEMENT PLANS; THE CITY ENGINEER SHALL HAVE THE AUTHORITY TO REQUIRE SUCH MODIFICATION OR DEPARTURE AND TO SPECIFY THE MANNER IN WHICH THE SAME IS TO BE COMPLETED, AT THE SOLE EXPENSE OF THE OWNER AND/OR CONTRACTOR. 2. CONTACT PUBLIC WORKS, (408) 777-3104, FOR INSPECTION OF GRADING, STORM DRAINAGE, AND PUBLIC IMPROVEMENTS. 3. ALL PUBLIC IMPROVEMENTS MUST BE COMPLETED PRIOR TO OCCUPANCY. 4. CONTRACTOR IS RESPONSIBLE FOR DUST CONTROL AND INSURING THE AREA ADJACENT TO THE WORK IS LEFT IN A CLEAN CONDITION. 5. CONTRACTOR SHALL REVIEW CITY DETAIL 6-4 ON TREE PROTECTION PRIOR TO ACCOMPLISHING ANY WORK OR REMOVING ANY TREES. 6. UTILIZE BEST MANAGEMENT PRACTICES (BMP'S) AS REQUIRED BY THE STATE WATER RESOURCES CONTROL BOARD, FOR ANY ACTIVITY, WHICH DISTURBS THE SOIL. 7. A WORK SCHEDULE OF GRADING AND EROSION & SEDIMENT CONTROL PLAN SHALL BE PROVIDED TO THE CITY ENGINEER BY AUGUST 15. NO HILLSIDE SHALL BE PERFORMED BETWEEN OCTOBER 1 TO APRIL 15. 8. TO INITIATE RELEASE OF BONDS, CONTACT THE PUBLIC WORKS INSPECTOR FOR FINAL INSPECTION. 9. ALL DOWNSPOUTS TO BE RELEASED TO THE GROUND SURFACE, DIRECTED AWAY FROM BUILDING FOUNDATIONS AND DIRECTED TO LANDSCAPED AREAS. 10. PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT OF WAY, THE CONTRACTOR WILL BE RESPONSIBLE FOR PULLING AN ENCROACHMENT PERMIT FROM THE PUBLIC WORKS DEPARTMENT. FIRE DEPARTMENT NOTES. 1. REVIEW OF THIS DEVELOPMENTAL PROPOSAL IS LIMITED TO ACCEPTABILITY OF SITE ACCESS AND WATER SUPPLY AS THEY PERTAIN TO FIRE DEPARTMENT OPERATIONS, AND SHALL NOT BE CONSTRUED AS A SUBSTITUTE FOR FORMAL PLAN REVIEW TO DETERMINE COMPLIANCE WITH ADOPTED MODEL CODES. PRIOR TO PERFORMING ANY WORK THE APPLICANT SHALL MAKE APPLICATION TO, AND RECEIVE FROM, THE BUILDING DEPARTMENT ALL APPLICABLE CONSTRUCTION PERMITS. 2. FIRE SPRINKLERS REQUIRED: AN AUTOMATIC RESIDENTIAL FIRE SPRINKLER SYSTEM SHALL BE INSTALLED IN ONE- AND TWO-FAMILY DWELLINGS AS FOLLOWS: IN ALL NEW ONE- AND TWO-FAMILY DWELLINGS AND IN EXISTING ONE- AND TWO-FAMILY DWELLINGS WHEN ADDITIONS ARE MADE THAT INCREASE THE BUILDING AREA TO MORE THAN 3,600 SQUARE FEET. EXCEPTION: A ONE-TIME ADDITION TO AN EXISTING BUILDING THAT DOES NOT TOTAL MORE THAN 1,000 SQUARE FEET OF BUILDING AREA. NOTE: THE OWNER(S), OCCUPANT(S) AND ANY CONTRACTOR(S) OR SUBCONTRACTOR(S) ARE RESPONSIBLE FOR CONSULTING WITH THE WATER PURVEYOR OF RECORD IN ORDER TO DETERMINE IF ANY MODIFICATION OR UPGRADE OF THE EXISTING WATER SERVICE IS REQUIRED. NOTE: COVERED PORCHES, PATIOS, BALCONIES, AND ATTIC SPACES MAY REQUIRE FIRE SPRINKLER COVERAGE. A STATE OF CALIFORNIA LICENSED (C-16) FIRE PROTECTION CONTRACTOR SHALL SUBMIT PLANS, CALCULATIONS, A COMPLETED PERMIT APPLICATION AND APPROPRIATE FEES TO THIS DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO BEGINNING THEIR WORK. CRC SEC. 313.2 AS ADOPTED AND AMENDED BY CUPMC 3. WATER SUPPLY REQUIREMENTS: POTABLE WATER SUPPLIES SHALL BE PROTECTED FROM CONTAMINATION CAUSED BY FIRE PROTECTION WATER SUPPLIES. IT IS THE RESPONSIBILITY OF THE APPLICANT AND ANY CONTRACTORS AND SUBCONTRACTORS TO CONTACT THE WATER PURVEYOR SUPPLYING THE SITE OF SUCH PROJECT, AND TO COMPLY WITH THE REQUIREMENTS OF THAT PURVEYOR. SUCH REQUIREMENTS SHALL BE INCORPORATED INTO THE DESIGN OF ANY WATER -BASED FIRE PROTECTION SYSTEMS, AND/ OR FIRE SUPPRESSION WATER SUPPLY SYSTEMS OR STORAGE CONTAINERS THAT MAY BE PHYSICALLY CONNECTED IN ANY MANNER TO AN APPLIANCE CAPABLE OF CAUSING CONTAMINATION OF THE POTABLE WATER SUPPLY OF THE PURVEYOR OF RECORD. FINAL APPROVAL OF THE SYSTEM(S) UNDER CONSIDERATION WILL NOT BE GRANTED BY THIS OFFICE UNTIL COMPLIANCE WITH THE REQUIREMENTS OF THE WATER PURVEYOR OF RECORD ARE DOCUMENTED BY THAT PURVEYOR AS HAVING BEEN MET BY THE APPLICANT(S). 2010 CFC SEC. 903.3.5 AND HEALTH AND SAFETY CODE 13114.7 4. ADDRESS IDENTIFICATION: NEW AND EXISTING BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. THESE NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE ARABIC NUMBERS OR ALPHABETICAL LETTERS. NUMBERS SHALL BE A MINIMUM OF 4 INCHES (101.6 MM) HIGH WITH A MINIMUM STROKE WIDTH OF 0.5 INCH (12.7 MM). WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. CFC SEC. 505.1 5. CONSTRUCTION SITE FIRE SAFETY: ALL CONSTRUCTION SITES MUST COMPLY WITH APPLICABLE PROVISIONS OF THE CFC CHAPTER 33 AND OUR STANDARD DETAIL AND SPECIFICATION SI-7. PROVIDE APPROPRIATE NOTATIONS ON SUBSEQUENT PLAN SUBMITTALS, AS APPROPRIATE TO THE PROJECT. CFC CHP. 33 SANITARY DISTRICT 1. CUPERTINO SANITARY DISTRICT CONNECTION PERMIT FEE ($250) FOR SINGLE FAMILY RESIDENTIAL ALREADY CONNECTED, BUT NEW CLEANOUT IS REQUIRED. (O.C. 7101-3) 2. CUPERTINO SANITARY DISTRICT DISCONNECTING & CAPPING FEE ($200) IS REQUIRED FOR THE SUBJECT IMPROVEMENTS. PLEASE DO NOT ISSUE ANY BUILDING PERMITS. (O.C. 7203) 3. NEW PLCO PER DISTRICT STANDARDS. SEE DETAIL 9 ON SHEET A-1.2 4. INSTALL NEW PROPERTY LINE CLEANOUT TO DISTRICT'S STANDARDS. SEE ATTACHED DETAIL. PROPERTY LINECLEANOUT MUST BE WITHIN 5 FEET OF THE PROPERTY LINE. CLEANOUT SHALL BE THE SAME DIAMETER AS THE STREET PORTION OF THE SERVICE LATERAL. GRAVITY LATERAL IS 4" DIAMETER. (O.C. 4101) 5. EXISTING SANITARY SEWER LATERAL SHALL BE DISCONNECTED AND CAPPED IN THE PRESENCE OF A DISTRICT INSPECTOR. OWNER TO CALL THE DISTRICT AT LEAST 48 HOURS PRIOR TO WORK TO SCHEDULE AND DISTRICTINSPECTOR. (O.C. 5203) 6. CUPERTINO SANITARY DISTRICT INITIAL (VISUAL) INSPECTION REQUIRED. CONTRACTOR SHALL LEAVE NEW PIPE INSTALLATION EXPOSED. DO NOT BACKFILL. OWNER TO CONTACT DISTRICT 48 HOURS PRIOR TO SCHEDULING A DISTRICT INSPECTOR FOR A VISUAL INSPECTION. (O.C. 5203) 7. CUPERTINO SANITARY DISTRICT FINAL (CCTV) INSPECTION AND APPROVAL OF THE NEW PROPERTY LINE CLEANOUT, POINT OF CONNECTION, AND DISTRICT LATERAL IS REQUIRED PRIOR TO CLEARANCE FOR CITY OF CUPERTINO FINAL INSPECTION. OWNER MUST ALLOW DISTRICT AT LEAST 48 HOURS' NOTICE TO SCHEDULE A DISTRICT INSPECTOR FOR A VIDEO INSPECTION. DISTRICT TO PROVIDE BUILDING DEPARTMENT WITH WRITTEN NOTIFICATION UPON COMPLETION OF INSPECTION. (O.C. 7102) 8. STORM WATER SURFACE OR ROOF DRAINS, OTHER GENERAL SURFACE WATER RUNOFF, OR CONDENSATION FROM ANY RESIDENTIAL HVAC EQUIPMENT SHALL NOT BE DISCHARGED TO THE SANITARY SEWER. 9. FEES CAN BE PAID AT THE DISTRICT OFFICE LOCATED AT 20863 STEVENS CREEK BOULEVARD, SUITE 100 IN CUPERTINO, CA BY CASH OR CHECK (PAYABLE TO "CUPERTINO SANITARY DISTRICT"). SEWER LATERAL WORK 1. ALL PROPOSED SEWER LATERAL WORK WALL BE DONE PER CITY PUBLIC WORKS DEPT. & BLDG. DEPT. SPECIFICATIONS. 2. ELEVATIONS & LOCATIONS OF ALL EXISTING UTILITIES SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO START OF ANY CONSTRUCTION AFFECTING SAID LINES. CONTACT USA @ (800) 642.2444 AT LEAST TWO WORKING DAYS PROIR TO EXCAVATION. 3. THE CONTRACTOR SHALL RESTORE ALL DAMAGED, REMOVED OR OTHERWISE DISTURBED WALLS, FENCES, SERVICES, UTILITIES, IMPROVEMENTS OR FEATURES OF WHATEVER NATURE, DUE TO CONTRACTOR'S WORK. 4. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH THE INSTALLATION OF FACILITIES BY PG & E, PACIFIC BELL, & CABLE TV INSTALLATION AS REQUIRED. VALVE BOXES & MANHOLES, & STRUCTURES TO BE SET TO GRADE IN CONCRETE AFTER PAVING. 5. ALL STREET MONUMENTS & OTHER PERMANENT MONUMENTS DISTURBED DURING CONSTRUCTION SHALL BE REPLACED BEFORE ACCEPTANCE OF THE IMPROVEMENT BY THE CITY ENGINEER. 6. FOR LANE CLOSURES. THE CONTRACTOR SHALL PREPARE A TRAFFIC CONTROL PLAN & OBTAIN APPROVAL FROM THE CITY PUBLIC WORKS ENGINEER BEFORE COMMENCING WORK. THE CONTRACTOR SHALL PROVIDE FLAGMEN, CONES OR BARRICADES AS NECESSARY TO CONTROL TRAFFIC & PREVENT HAZARDOUS CONDITIONS PER THE REQUIREMENT OF THE CITY ENGINEER. 7. NO TRENCHES SHALL BE LEFT OPEN OVERNIGHT IN STREET AREA, USE STEEL PLATING OR HOT -MIX ASPHALT AS REQUIRED TO PROTECT OPEN TRENCHES OVERNIGHT. 8. EXISTING IN -GROUND SEPTIC TANK TOBE REMOVED (1/3 OF BOTTOM MIN.), FILL WITH SAND (90% COMPACTION) TYP. SITE PLAN NOTES A. GENERAL: • SEE OWNER FOR UP -GRADE HARDSCAPE FINISH FOR DRIVEWAY, WALKWAY & PATIO • ALL METAL ANCHORS, FASTENERS, CONNECTORS, ETC. THAT WILL BE IN CONTACT WITH PRESSURE TREATED LUMBER MUST BE HOT -DIPPED GALVANIZED OR OTHER APPROVED CORROSION RESISTANT MATERIAL. B. BUILDING SETBACK: 1. CONTRACTOR TO VERIFIED BUILDING SETBACK AND ADJUST WALL TO MEET MINIMUM SETBACK. 2. PRIOR TO FOUNDATION INSPECTION BY THE CITY, THE LICENSED LAND SURVEYOR OF RECORD SHALL PROVIDE A WRITTEN CERTIFICATION THAT ALL BUILDING SETBACKS COMPLY WITH THE APPROVED PLANS. WHICH NOTE SHALL REPRESENT A CONDITION WHICH MUST BE SATISFIED TO REMAIN IN COMPLIANCE WITH THIS DESIGN REVIEW APPROVAL. C. GRADING & DRAINAGE: SEE CIVIL ENGINEER PLAN. 1. ARROWS INDICATE DIRECTION OF SURFACE DRAINAGE. 2. GROUND IS TO SLOPE AWAY FROM FOUNDATION 5% FOR A DISTANCE OF 10 FT AWAY FROM THE BUILDING; IF 10 FT. CANNOT BE MEET, PROVIDE SWALES. PROVIDE 2% SLOPE IF IMPERVIOUS SURFACE IS USED. CRC R401.3. NO CONCENTRATED FLOW ACROSS THE RIGHT-OF-WAY. NO DRAINAGE ONTO NEIGHBORING PROPERTIES. ALL DRAINAGE TO LANDSCAPE. 3. DIRECT ROOF RUNOFF SHALL BE: • DIRECT ROOF RUNOFF ONTO VEGETATED AREAS • DIRECT RUNOFF FROM SIDEWALKS, WALKWAYS, AND/OR PATIOS ONTO VEGETATED AREAS; • DIRECT RUNOFF FROM DRIVEWAYS AND/OR UNCOVERED PARKING LOTS ONTO VEGETATED AREAS. • CONSTRUCT SIDEWALKS, WALKWAYS AND/OR PATIOS WITH PERMEABLE SURFACES 4. CONNECT ALL DOWNSPOUTS TO 3" SOLID DRAIN LINE AROUND PERIMETER OF HOUSE DRAIN TO CURB OR PROVIDE CONCRETE SPLASH BLOCK AT DOWNSPOUT LOCATIONS FOR DRAINAGE AWAY FROM STRUCTURE. D. GEOTECHNICAUSOIL REPORT: 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE GEOTECHNICAL/SOIL REPORT. E. UTILITIES: 1. CONTRACTOR TO VERIFY LOCATION OF ALL UTILITIES @ JOB SITE. 2. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH THE INSTALLATION OF FACILITIES BY PG & E, PACIFIC BELL, & CABLE TV INSTALLATION AS REQUIRED. VALVE BOXES & MANHOLES, & STRUCTURES TO BE SET TO GRADE IN CONCRETE AFTER PAVING. F. CONSTRUCTION SITE: 1. CONSTRUCTION SITE SHALL BE ENCLOSED BY 6' OPAQUE FENCE AT ALL TIMES DURING CONSTRUCTION. 2. NO CONSTRUCTION MATERIAL, EQUIPMENT, PORTABLE TOILETS, TRASH CONTAINERS, OR DEBRIS SHALL BE PLACED IN THE PUBLIC RIGHT-OF-WAY. 3. A TRASH CONTAINER SHALL BE MAINTAINED ON SITE AT ALL TIMES AND DEBRIS ON SITE WHICH COULD OTHERWISE BLOW AWAY, SHALL BE REGULARLY COLLECTED AND PLACED IN CONTAINER. 4. ALL CONSTRUCTION DEBRIS (WOOD SCRAPS AND OTHER DEBRIS, WHICH CANNOT BLOW AWAY) SHALL BE PILED WITHIN THE PROPERTY LINES OR THE PROJECT IN A NEAT AND SAFE MANNER. ADJACENT BUILDING U) z J U U w w of U rr z Q ww U U U rn 0 z J rr w ,11r. r t z J U N w w w = zQ w w OQ 5'-6" cUn U)i B.S.L. 0 • z 24" a x• ADU FIRE SPRINKLER F.S. 100.6 SCREEN TREES PER LANDSCAPE ARCHITECT PLANS S 16'15 .06 • X • X • X - X • X •M ifl �- in _ _/ i J ` 1 C6 POOL N "REMOVE (E) 34'x16' REMOVE (E) 10" TREE 11 9'-6" � 12 TREE ooe i PAVERS REMOVE (E) SPA �.t Ci TREE 8�6, �1�2� X REMOVE (E) 10" TREE i 0 � o L z Z REAR YARD oa ARTIFICIAL o GRASSco / P.A. O EO o zo M Pokx / 30" 1 P.A. _ - - - 10050 St. - - - STEPS \pp PAVERS \>/F lJ I �I BALCONY I POOL EQUIP. REMOVE (E)X LL P.A. (3)3" TREE ` P.A. I II r 8080 I I w ARTIFICIAL W GRASS' \ 64011 I� II �TREE 7 x I ' 10'-4 0 aZ I I I I A/C A/C P.A. �� it I m 16 00. o I I I 0 15'-0" TO 2ND FLOOR 0 M 0 I I o� I GARAGE F.S. 101.7 m LL---pum PORCH N 15'-0" TO 2ND FLOOR I` (3)5030 9'-6" B.S.L. NEW RESIDENCE r (3)3030 FIX � J J ARTIFICIAL FIRE SPRINKLER F.F. 102.9 I GRASS T-6" } 30_�� =JJ �r _ 0 z o � a 00 6060 = PORCH F.S. 102.3 P.A. TR° P.A. �xx� L- STEPS 1,6E 18" SQ. 45" TALL STONE VENEER LIGHT OLUMNS. GATE q PAVERS PAVERS CONNECT (E) WATER LINE w/ (N) 1 (N)DRIVEWA 1/2" PVC PIPE TO (N) HOUSE SHUT PAVERS o 24" H1. STONE \ OFF VALVE PER WATER CO. LL WALL w/ CAP CONTRACTOR TO VERIFY ON FIELD (N) BACKFLOW P.A. N o PREVENTER SHEET IFICIAL • ~ A1.3, DETAIL 8 GRASS o M (N) CLEAN OUT PER SHEET A1.3, DETAIL 7 . TREE • . • • EN0016115►► 36" HI WOOD FENCE (E)C/O CONTRACTOR TO VERIFY ON FIELD E 4" MIN. SEWER LATERAL. X ADJACENT BUILDING � r1 i ARTIFICIAL I I GRASS w 400AMP I I o PANEL F�.A I N 2„ i 12' � P.U. .I, •, PAVERS) FRONT YARD CONNECT (N) GAS LINE TO (E) GAS LINE vi ARTIFICIAL PER PG&E. FIELD VERIFY. 0° GRASS q ARTIFICIAL N GRASS I I CONNECT (N) ELECTRICAL LINE TO (E) 3'-0' 6'-0" T-0" T-0" I i ELECTRICAL POLE. ALL SERVICE LINES (ELECTRIC, PHONE, AND/OR CABLE) FROM THE HOUSE TO THE POLE SHALL BE UNDERGROUNDED. AN ENCROACHMENT PERMIT WILL BE REQUIRED. CONTACT PG&E ATE FOR DESIGN. 36" 111 WOOD FENCE X>\ POWER POLE CONC SIDEWALK EH CONC ROLLED CURB FYSB IMPERVIOUS PAVING Total front yard setback area = 1600 sf MANN DRIVE(601) 40% allowed impervious = 640 sf Driveway ayy= = 306 sf Front Walk = 241 sf Columns = 13.5 sf Rock Wall = 15 sf SITE PLAN & HORIZONTAL CONTROL PLAN Total = 575.5 sf SCALE: 1" = 10' 0" 575.5 sf /1600 = 36% OK less than 40% THE HORIZONTAL CONTROL PLAN IS PREPARED BASED ON THE BOUNDARY SURVEY PREPARED BY THE PROJECTS LICENSED SURVEYOR. SEE LANDSCAPE ARCHITECT PLANS PROJECT DATA ASSESSOR'S PARCEL #: 326-19-004 PROJECT ADDRESS: 10092 MANN DRIVE, CUPERTINO CA 95014 PROPERTY OWNER: KEVIN CHIAO & CRYSTAL HUANG (408)472-4127 kevin@ownerslogic.com 10092 MANN DRIVE, CUPERTINO CA 95014 PROJECT CONTACT PERSON: TRI HONG (408)829-6083 tdhdesign@hotmail.com 19034 BONNET WAY, SARATOGA, CA. 95070 PROJECT SCOPE OF WORK: DEMOLITION EXISTING ONE STORY HOUSE OF 2,177 S.F. (UNDER SEPARATE PERMIT). PROPOSED TO CONSTRUCTED A NEW TWO STORY HOME WITH ATTACHED TWO CAR GARAGE. EXISTING ZONING: R1-6 OCCUPANCY: R3-U TYPE OF CONSTRUCTION: V-B FULLY-SPRINKLERED INSTALLED PER NFPA 13D 2022 EXISTING USE: ONE STORY SINGLE FAMILY RESIDENCE PROPOSED USE: TWO STORY SINGLE FAMILY RESIDENCE GROSS LOT SIZE: 10,000 S.F. NET LOT SIZE: 10,000 S.F. FLOOR AREA RATIO CALCULATION: MAX. F.A.R.: 45% (10,000) = 4,500 S.F. FIRST FLOOR: 2,496 S.F. 2 CAR GARAGE: 420.25 S.F. SECOND FLOOR: 1,582 S.F. (54.24% OF FIRST FLOOR) PROPOSED FA.R.: 4,498.25 S.F. (44.98%) DETACH ADU: 796.5 BUILDING COVERAGE CALCULATION: MAX. COVERAGE: 45% (10,123) = 4,555 S.F. FIRST FLOOR & GARAGE: 2,916.25 S.F. COVERED PORCH: 182 S.F. COVERED PATIO: 656 S.F. EAVES OVER HANG: 479 S.F. PROPOSED COVERAGE: 4,233.25 S.F. (41.82%) SET BACK REQUIREMENT REQUIRED PROPOSED SETBACKS 1st floor 2nd floor 1st floor 2nd floor COMPLIANT FRONT 20'-0" 25-0" 20'-0" 30'-10" YES LEFT SIDE 5'-6" (15- COMBINE) 15'4" 5'-6" 15-0" YES RIGHT SIDE 9'-6" (15' COMBINE) 15-0" 9'-6" 15-0" YES REAR 20'-0" 25'-0" 39'-6" 39'-6" YES CONSULTANTS LIST DESIGNER STRUCTURAL ENGINEER MANUFACTURER CONTACT TDH DESIGN WESLEY LIU ENGINEERING • 'Eagle' Roofing: 19034 BONNET WAY 7246 SHARON DRIVE #0 (800) 998-3245 www.eagleroofing.com'Gaf' Roofing: SARATOGA, CA 95070 SAN JOSE, CA 95129 (877) 423-7663 www.gaf.com/ 408.829.6083 408.973.1839 • 'Velux' Skylight: tdhdesign@HOTMAIL.COM wesleyliu@YAHOO.COM (800) 888-3589 www.veluxusa.co ENERGY CONSULTANT CIVIL ENGINEER • 'Grace Construction' Flashing CARSTAIRS ENERGY CALC. RW ENGINEERING, INC. (866) 333-3726 www.gcpat.com 904 EVERT COURT 505 ALTAMONT DRIVE PASO ROBLES, CA 93446 MILPITAS, CA 95035 805.904.9048 408-420-6283 timmycarstairs@YAHOO.COM rwengineering@GMAIL.COM GENERAL NOTES 1. ALL WRITTEN DIMENSIONS SHALL OVER TAKE PRECEDENCE OVER SCALED DIMENSIONS. 2. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF TDH DESIGN PRIOR TO COMMENCING. 3. LOCATION OF UTILITIES AND EXISTING CONDITIONS AT SITE TO BE VERIFIED PRIOR TO CONSTRUCTION BIDDING. 4. ALL WORK APPLIANCES AND EQUIPMENT SHALL COMPLY WITH C.E.0 TITLE 24 RESIDENTIAL ENERGY STANDARDS. 5. BUILDERICONTRACTOR: • RESPONSIBILITY FOR METHOD AND MANNER OF CONSTRUCTION AND FOR ALL JOB SITE SAFETY DURING CONSTRUCTION. • SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR METHOD & MANNER OF ALL WATERPROOFING. BUILDER/CONTRACTOR SHALL REFER TO SOIL REPORT, GRADING & DRAINAGE PLAN, AND ALL WATERPROOFING WORK TO BE PERFORMED BY NHQ CERTIFIED WATERPROOFING COMPANY. • SHALL PROVIDE THE BUILDING OWNER, MANAGER, AND THE ORIGINAL OCCUPANTS A LIST OF THE ENERGY -SAVING CONSERVATION FEATURES DEVICES, MATERIALS, AND COMPONENTS INSTALLED IN THE BUILDING, AND INSTRUCTIONS ON HOW TO USE THEM EFFICIENTLY, SUCH FEATURES INCLUDE HEATING, COOLING, WATER HEATING, AND LIGHTING SYSTEMS, AS WELL AS INSULATION, WEATHER STRIPPING WINDOW SHADES, AND THERMAL MASS MATERIALS, THE INSTRUCTIONS SHALL BE CONSISTENT WITH SPECIFICATIONS BUT FORTH BY THE EXECUTIVE DIRECTOR. 6. FIRE SPRINKLERS TO BE REVIEWED AND APPROVED UNDER A SEPARATE PERMIT. 7. DEMOLITION PERMIT OBTAIN AT THE CUPERTINO BUILDING DEPARTMENT. PROVIDE ALL NECESSARY DOCUMENTS AS STATED IN THE DEMOLITION PERMIT PACKET WHICH IS AVAILABLE ON-LINE (ALSO KNOW AS THE PROCEDURE CHECKLIST FOR DEMOLITION PERMITS) FOR EXAMPLE, PG&E SHUTOFF, J-NUMBER FOR ASBESTOS REMOVE FROM BAY AREA AIR QUALITY MANAGEMENT, PEST CONTROL, ETC. 8. SOLAR SYSTEM SHALL BE PERMITTED, INSTALLED, AND INSPECTED PRIOR TO FINAL OF THE RESIDENCE. 9. A/C UNITS: PLEASE MAKE A NOTE ON THE PLANS THAT THE AC UNIT LOCATION IS NOT APPROVED AS PART OF THIS PERMIT AND WILL BE REVIEWED IN THE BUILDING PERMIT SUBMITTAL FOR COMPLIANCE WITH CMC CHAPTER 10.48 COMMUNITY NOISE ORDINANCE. 10. ENGINEER -OF -RECORD WILL PERFORM THE SPECIAL INSPECTION FOR SHEAR WALL NAILING FOR THIS PROJECT. (NOTE IS REQUIRED BY THE CUPERTINO BUILDING DIVISION.) SHEET INDEX ARCHITECTURAL A-0 COVER SHEET A-1.1 SITE PLAN A-1.2 EXISTING SITE PLAN w/ DEMOLITION & STREETSCAPE A-1.3 CITY STANDARD DETAILS A-2.1 FIRST FLOOR PLAN A-2.2 SECOND FLOOR PLAN & FLOOR AREA CALC. DIAGRAM A-3.1 ELEVATIONS A-3.2 ELEVATIONS A-4 SECTIONS A-5 ROOF PLAN A-6 ADU PLANS SU-1 SURVEY C-1 GENERAL NOTES C-2 GRADING AND DRAINAGE PLAN C-3 EROSION CONTROL PLAN BMP BEST MANAGEMENT PRACTICE L-0 WATER CHECKLIST L-1 PLANTING PLAN L2 HYDROZONE PLAN VICINITY MAP ComplianceBrldge s %, Corporation f1-r �V Mary Avenue Dog P rk9 ark Financial Woodbury Or Fitzgerald Or ti o` University Way o = �mQcaSITE � Monte C! Oakdell PI E O w N 4L aaktiiew Ln 9 United States as � a a Postal Service Starbucks ekberry FarStevens Creek Blvd 19 The City Fish - m G6f Course p° Spring Wells Day Spa F Granada Ave a Granada Ave Hermosa Ave NORTH' Z a CL W 0 M rn Z Q U O LU U ~ z LU O w wo � rn W ad U Cq N LU j M Z w 49 o Q Z z z Q CV rn 0 0 O LU O O 0 cY) U') 2 Q�) aD 0')2 � U i O (0 00(D Z) .-� U o0 z 07 O >Q LU Z Z 0 M O O� DRAWN LOC HUA CHECKED TRI HONG SIGNATURE DATE APRIL 2024 SCALE AS SHOWN JOB 1224 SHEET Aml ol