Loading...
A-00.01PROPOSED SITE PLAN SC : 1/8" = 1'-0" 1 4 : 12 4 : 12 4 : 12 4 : 12 4 : 12 4 : 12 4 : 12 4 : 12 4 : 12 4 : 12 4 : 12 4 : 12 4 : 12 4 : 12 4 : 12 4 : 12 4 : 12 4 : 12 4 : 12 F F F F F F F F F F F F F F F F F F F F F F F F F F F F 4 : 12 4 : 12 4 : 12 4 : 12 R 4' 4'-2" 10' 31'-6" 3' 6'-2"20' 15' 36'-1" 12'-9" 12'-11" 20'-7" 39'-6" 6' 7'-8" 1'-5" 35' 4'-10" 18'-5" 18'-5" 12'-2" 5'-8" 4' 12'-6" 23'-11" 27'-6"29' 30°3 0 ° APPROVED ADDRESS NUMBERS ON BUILDING ELEVATIONS, SHALL BE PLAINLY LEGIBLE AND VISIBLE FROM THE ADJACENT ACCESS STREET OR ROAD FRONTING THE PROPERTY. THE NUMBERS NEED TO CONTRAST WITH THEIR BACKGROUND, AND BE A MINIMUM OF 4" HIGH, WITH A MINIMUM STROKE OF 1/2". ADDRESS NUMBERS SHALL BE ARABIC NUMBERS OR ALPHABETICAL LETTERS. NUMBERS SHALL NOT BE SPELLED OUT. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, ADDRESS IDENTIFICATION SHALL BE PROVIDED IN ADDITIONAL APPROVED LOCATIONS TO FACILITATE EMERGENCY RESPONSE. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING ADDRESS CANNOT BE VIEWED FROM A PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. ADDRESS IDENTIFICATION SHALL BE MAINTAINED. CRC 319.1 FRONT SETBACK LINE SKY L. 24" X 30" ORA NGE A VE. WALK WAY DRIVE WAY 42.12' 42.12' 105.15' 105.15' 2ND FLOOR 2ND FLOOR 2ND FLOOR 2ND FLOOR 6'' SHRUB TO BE REMOVE 22'' CALIFORNIA OAK TREE TO REMAIN GATE GATE PRIVATE YARD: 339 SQF. 2ND FLOOR 6' PUBLIC ROAD, HIGHWAY & MAINTENANCE EASEMENT G 10095 ORANGE AVENUE A.P.N.: 357-16-095 PARCEL AREA: 4,428 SF ROOF PEAK EL: 115.60' ℄ 6' WOOD FENCE ADJACENT BUILDING 8' WOOD FENCE 6' WOOD FENCE ADJACENT BUILDING DRIVE CARPORTSTEPS GAS METER STEPS STEP BLOCK FLAGSTONE SHED A/C PLANTER PLANTER WOOD DECK BRICK STEPS STEPS PLANTER PLTR FLAGSTONE STEP WATER METER MANHOLE SIGN 3' WOOD FENCE GATE GATE CATCH BASIN INV: -4.45' MAIL BOX POWER POLE WOOD DECK 8.28' 8.65' 18.31' 18.03' 13.31' 13.53' 49.92' 49.55' ADJ BLDG 4.84' S'LY OF P/L ADJ BLDG 5.21' S'LY OF P/L ADJ BLDG 4.91' N'LY OF P/L ADJ BLDG 4.62' N'LY OF P/L S C SEWER CLEAN OUT WF 0.09' N'LY OF P/L 101.60 101.20 101.51101.52 101.56 101.67 101.73 101.70 101.75 101.73 101.84 101.95 101.68102.07101.93 101.28 101.43 101.75 101.87 101.68 102.14 102.20 101.96 102.18 101.95 101.69 101.61 101.56 101.56 101.70 101.79 101.80 101.94 101.77 101.74 101.69 101.58 101.76 101.68 101.85 102.10 101.92 101.82 101.65 101.64 101.85 102.06 1 0 1 . 7 0 101.82 102.10 102.20 101.96 101.85 102.31 101.85 101.98 102.08101.86 102.00 102.06 102.04 102.33 101.96 101.97 102.02 101.97 101.91 102.04 102.23 102.02 102.04 102.54 102.05 102.21 102.05 102.04 102.18 102.33 102.05 101.99 102.01 101.91 102.12 102.08 103.37 102.01 102.17 102.23 102.23 102.36 102.42 102.72 102.21 102.74 102.63 102.44102.33 102.34 102.39 102.15 102.47 102.28 102.37 102.47102.54 102.55 102.64 102.40 102.33 102.85 102.62 102.38 102.48 102.44102.56102.42 102.45102.49 102.49 102.49 102.52102.51 101.85 103.56 102.76 102.66 102.67 102.60 102.62 102.63 102.54 102.69 102.87 102.66 103.58 101.59 102.07 T.E.= 103.65' T.E.= 103.65' BOLLARD 22" (TYP) OAK 6" TREE N89°49'16"E 105.15' N89°49'16"E 105.15' N0°00'20"E42.12' N0°00'20"E42.12' S89° 59' 40"E 15.00' PLTR O H O H O H O H GATE STEP STONE (TYP) STEP STONE (TYP) OVERHEAD WIRE WF 0.39' W'LY OF P/L WF 1.15' N'LY OF P/L WF 0.59' W'LY OF P/L WF 0.20' S'LY OF P/L WF 0.19' S'LY OF P/L WF 0.94' N'LY OF P/L HOSE BIB 4' PUBLIC ROAD, HIGHWAY & MAINTENANCE EASEMENT RECORDED 02/24/1954 IN BOOK 2820, PAGE 584 42.15 S36°23'00"E 33.93 N00°00'20"E 25.0 N89°49'16"W PARCEL 3 (INGRESS/EGRESS EASEMENT) PARCEL 2 & PUBILTY UTILITY & STREET EASEMENT WIN. PRIVACY VIEWSHED FRONT YARD 35'.0 X 42.12' 1470 SQF MOTION SENSOR MOTION SENSOR MOTION SENSOR MOTION SENSOR MOTION SENSOR MOTION SENSOR MOTION SENSOR MOTION SENSOR 15% (FAR): 0.15 X 1803= 270.45 NEW FRONT YARD TREE SHALL BE 24-INCH BOX OR LARGER, WITH A MINIMUM HEIGHT OF 6 FEET 2ND FLOOR 2ND FLOOR 2ND FLOOR 1/8 INCH = 1 FEET 0 2 4 6 8 10 20 30 GRAPHIC SCALE : F F 02 02 02 PROJECT NAME: ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SHEET NUMBER: SHEET TITLE: REVISION TABLE: REVISION DATE BY 4010 MOORPARK AVE#101, SAN JOSE, CA 95117 TELL: (415)254.1606 E-MAIL: OFFICE@AMSDESIGNLLP.COM THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. AMS DESIGN DESIGN A -00.01 1/8'' = 1' COVER SHEET/ PROPOSED SITE PLAN DEP PROJECT ID: DATE: SCALE: DRAWN BY: ORANGE RESIDENCE 10095 ORANGE AVE., CUPERTINO, CA 95014 12/07/2023 P.J.PLN01 -------- 2306-10 JUNE 2023 P.J. Azadeh Masrour PROPERTY LOCATION / NTS 357-16-095 NEW CONSTRUCTION 10095 ORANGE AVE, CUPERTINO, CA 95014 R1-7.5 R - 3 / U V - B TWO (2) STORY SPRINKLERED ASSESSOR'S PARCEL NUMBER: PROJECT TYPE: PROJECT LOCATION: ZONING: OCCUPANCY GROUP: CONSTRUCTION TYPE: NUMBER OF FLOORS: FIRE PROTECTION: PROJECT DATA: NEW 2 STORY CUSTOM HOME 1803 SQ BUILDING AREA INCLUDING 3 BEDS, 3 BATH, 1 LAUNDRY AND 1 CAR GARAGE. ALSO 589 SQ ATTACHED ADU. SCOPE OF WORK: ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS-DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. GENERAL NOTES: AN AUTOMATIC FIRE SPRINKLER SYSTEM IS REQUIRED. PLANS, HYDRAULIC CALCULATIONS AND SYSTEM SPECIFICATIONS FOR THE AUTOMATIC FIRE SPRINKLER SYSTEM SHALL BE SUBMITTED FOR REVIEW AND APPROVAL UNDER A SEPARATE PERMIT. AREA CALCULATION: 1 0 0 9 5 O R AN G E AV E ., C UPER T IN O , C A , 95014 17500 SQF PROJECT SUMMARY: LOS ALT OS, CA A- AN AUTOMATIC RESIDENTIAL FIRE SPRINKLERS SYSTEM SHALL BE INSTALLED IN ONE- AND TWO-FAMILY DWELLINGS AS FOLLOWS: IN ALL NEW ONE- AND TWO-FAMILY DWELLINGS AND IN EXISTING ONE- AND TWO-FAMILY DWELLINGS WHEN ADDITIONS ARE MADE THAT INCREASE THE BUILDING AREA TO MORE THAN 3,600 SQUARE FEET PER SEC R313.2.1. EXCEPTION: A ONE-TIME ADDITION TO AN EXISTING BUILDING THAT DOES NOT TOTAL MORE THAN 1,000 SQUARE FEET OF BUILDING AREA. NOTE: THE OWNER(S), OCCUPANT(S) AND ANY CONTRACTOR(S) OR SUBCONTRACTOR(S) ARE RESPONSIBLE FOR CONSULTING WITH THE WATER PURVEYOR OF RECORD IN ORDER TO DETERMINE IF ANY MODIFICATION OR UPGRADE OF THE EXISTING WATER SERVICE IS REQUIRED. NOTE: COVERED PORCHES, PATIOS, BALCONIES, AND ATTIC SPACES MAY REQUIRE FIRE SPRINKLER COVERAGE. A STATE OF CALIFORNIA LICENSED (C-16) FIRE PROTECTION CONTRACTOR SHALL SUBMIT PLANS, CALCULATIONS, A COMPLETED PERMIT APPLICATION AND APPROPRIATE FEES TO THIS DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO BEGINNING THEIR WORK. SECTION R313.2 AS ADOPTED BY CUPMC. B- POTABLE WATER SUPPLIES SHALL BE PROTECTED FROM CONTAMINATION CAUSED BY FIRE PROTECTION WATER SUPPLIES. IT IS THE RESPONSIBILITY OF THE APPLICANT AND ANY CONTRACTORS AND SUBCONTRACTORS TO CONTACT THE WATER PURVEYOR SUPPLYING THE SITE OF SUCH PROJECT, AND TO COMPLY WITH THE REQUIREMENTS OF THAT PURVEYOR. SUCH REQUIREMENTS SHALL BE INCORPORATED INTO THE DESIGN OF ANY WATER-BASED FIRE PROTECTION SYSTEMS, AND/ OR FIRE SUPPRESSION WATER SUPPLY SYSTEMS OR STORAGE CONTAINERS THAT MAY BE PHYSICALLY CONNECTED IN ANY MANNER TO AN APPLIANCE CAPABLE OF CAUSING CONTAMINATION OF THE POTABLE WATER SUPPLY OF THE PURVEYOR OF RECORD. FINAL APPROVAL OF THE REQUIREMENTS OF THE WATER PURVEYOR OF RECORD ARE DOCUMENTED BY THAT PURVEYOR AS HAVING BEEN MET BY THE APPLICANT(S). 2010 CFC SEC. 903.3.5 AND HEALTH AND SAFETY CODE 13114.7. C- APPROVED NUMBERS OR ADDRESSES SHALL BE PLACED OMN ALL NEW AND EXISTING BUILDINGS IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. PER CFC SEC. 505 D- ALL CONSTRUCTION SITES MUST COMPLY WITH APPLICABLE PROVISIONS OF CFC CHAPTER 14 AND SANTA CLARA COUNTY'S FIRE DEPARTMENT'S STANDARD DETAIL AND SPECIFICATION SI-7. E- PHOTOELECTRIC SMOKE DETECTORS SHALL BE PROVIDED AT BOTH THE TOP AND BOTTOM OF THE STAIRCASE. F- PHOTOELECTRIC SMOKE ALARMS SHALL BE PROVIDED IN AREAS LEADING TO SLEEPING ROOMS AND ON EVERY LEVEL. SMOKE ALARMS WITHIN SLEEPING ROOMS SHALL BE DUAL SENSOR PHOTOELECTRIC/IONIZATION. G- SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS SHALL BE INTERCONNECTED PER RESIDENTIAL CODE. H- A NFPA 13-D FIRE SPRINKLER SYSTEM SHALL BE INSTALLED UNDER SEPERATE PERMIT. I- A SEPARATE PERMIT FOR THE SPRINKLER SYSTEM SHALL BE APPLIED FOR BUREAU OF FIRE PREVENTION. FIRE NOTES:LOCAL TABLES / NOTES: A- APPROVAL OF THESE PLANS DOES NOT RELEASE THE OWNER AND/OR CONTRACTOR OF THE RESPONSIBILITY FOR THE CORRECTIONS OF MISTAKES, ERRORS, OR OMISSIONS CONTAINED THEREIN. IF DURING THE COURSE OF CONSTRUCTION IMPROVEMENTS, PUBLIC INTEREST REQUIRES A MODIFICATION OF/ OR A DEPARTURE FROM THE CITY OF CUPERTINO SPECIFICATION OR THESE IMPROVEMENT PLANS ,THE CITY ENGINEER SHALL HAVE THE AUTHORITY TO REQUIRE SUCH COMPLETED , AT THE SOLE EXPENSE OF THE OWNER AND/OR CONTRACTOR. B- CONTACT PUBLIC WORKS,(408)777-3104 , FOR INSPECTION OF GRADING,STORM DRAINAGE, AND PUBLIC IMPROVEMENTS. C- ALL PUBLIC IMPROVEMENTS MUST BE COMPLETED PRIOR TO OCCUPANCY. D- CONTRACTOR IS RESPONSIBLE FOR DUST CONTROL AND ENSURING THE AREA ADJACENT TO THE WORK IS LEFT IN A CLEAN CONDITION. E- CONTRACTOR SHALL REVIEW CITY DETAIL 6-4 ON TREE PROTECTION PRIOR TO ACCOMPLISHING ANY WORK OR REMOVING ANY TREES. F- UTILIZE BEST MANAGEMENT PRACTICES (BMP's) AS REQUIRED BY THE STATE WATER RESOURCES CONTROL BOARD, FOR ANY ACTIVITY, WHICH DISTURBS THE SOIL. G- A WORK SCHEDULE OF GRADING AND ORISON & SEDIMENT CONTROL PLAN SHALL BE PROVIDED TO THE CITY ENGINEER BY AUGUST 15. NO HILLSIDE GRADING SHALL BE PERFORMED BETWEEN OCTOBER 1 TO APRIL 15. H- ALL NEW ELECTRICAL SERVICE (POWER,PHONE,AND/OR CABLE) SHALL BE UNDERGROUNDED. I- TO INITIATE RELEASE OF BONDS,CONTACT THE PUBLIC WORKS INSPECTOR FOR FINAL INSPECTION. J- A LICENSED LAND SURVEYOR OR AUTHORIZED CIVIL ENGINEER WILL PREPARE AND SUBMIT,TO THE PUBLIC WORKS DEPT,AN ELEVATION CERTIFICATE FOR THE NEW STRUCTURE/ADDITION. K- TO INITIAL RELEASE OF BONDS, CONTACT THE PUBLIC WORKED INSPECTOR FOR FINAL INSPECTION. L- ALL DOWNSPOUTS TO BE RELEASED TO THE GROUND SURFACE, DIRECTED AWAY FROM BUILDING FOUNDATIONS AND DIRECTED TO LANDSCAPED AREAS. M- PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT OF WAY, THE CONTRACTOR WILL BE RESPONSIBLE FOR PULLING AN ENCROACHMENT PERMIT FROM THE PUBLIC WORKS DEPARTMENT. PUBLIC WORKS NOTES: A- THE PROPERTY OWNER SHALL RECORD A COVENANT ON THE PROPERTY FOR THE NEW TREES/SHRUBS PLANTED FOR PURPOSE OF REQUIRED REPLACEMENT TREES, PRIVACY PROTECTION, AND REQUIRED FRONT YARD TREE. B- FOLLOWING COMPLETION OF CONSTRUCTION, AN AFFIDAVIT FROM AN ISA-CERTIFIED ARBORIST SHALL BE PROVIDED CONFIRMING THAT THE NEW TREES HAVE BEEN PLANTED PROPERTY AND ACCORDING TO PLAN. C- A PLANNING DIVISION INSPECTION IS REQUIRED TO VERIFY EXTERIOR MATERIALS/FINISHES, TREES, LANDSCAPING, AND SITE WORK. D- A CERTIFIED LANDSCAPE PROFESSIONAL SHALL CONDUCT A LANDSCAPE INSTALLATION AUDIT AFTER THE LANDSCAPING AND IRRIGATION SYSTEM HAVE BEEN INSTALLED PER CHAPTER 14.15(LANDSCAPE ORDINANCE).THE FINDINGS OF THE ASSESSMENT SHALL BE CONSOLIDATED INTO A LANDSCAPE INSTALLATION REPORT PROVIDED TO THE PLANNING DIVISION. E- THE PROPERTY OWNER SHALL SIGN A LANDSCAPE MAINTANCE AGREEMENT PER CHAPTER 14.15(LANDSCAPE ORDINANCE), PREPARED BY THE CITY,AND RECORD IT WITH SANTA CLARA CO. RECORD'S OFFICE. THE PROPERTY OWNER SHALL CONTACT THE PLANNING DIVISION IN ADVANCE OF THE FINAL TO PREPARE THE AGREEMENT. F- A CERTIFIED LANDSCAPE PROFESSIONAL SHALL PROVIDE A LANDSCAPE AND IRRIGATION MAINTENANCE SCHEDULE PER CHAPTER 14.15(LANDSCAPE ORDINANCE) TO THE PLANNING DIVISION. REQ. PRIOR TO FINAL OCCUPANCY: CUPERTINO CODE: CUPERTINO MUNICIPAL CODE CHAPTER 16.54 AMENDS THE CALIFORNIA ENERGY CODE AND REQUIRES THAT EACH NEWLY CONSTRUCTED BUILDING BE CONSTRUCTED AS AN ALL-ELECTRIC BUILDING. AN ALL-ELECTRIC BUILDING IS A BUILDING THAT HAS NO NATURAL GAS OR PROPANE PLUMBING INSTALLED WITHIN THE BUILDING, AND THAT USES ELECTRICITY AS THE SOLE SOURCE OF ENERGY FOR ITS SPACE HEATING, WATER HEATING, COOKING APPLIANCES, OUTDOOR KITCHENS, OUTDOOR FIREPLACES, AND CLOTHES DRYING APPLIANCES. CUPERTINO MUNICIPAL CODE CHAPTER 16.58 AMENDS THE CALIFORNIA GREEN BUILDING STANDARDS CODE AND REQUIRES THAT NEWLY CONSTRUCTION ONE- AND TWO-FAMILY DWELLINGS WITH ATTACHED PRIVATE GARAGES SHALL INSTALL A LEVEL 2 EV READY CIRCUIT AND A LEVEL 1 EV READY CIRCUIT. CODE EDITIONS: A. B. C. D. E. F. G. H. I. J. CALIFORNIA RESIDENTIAL: CALIFORNIA BUILDING: CALIFORNIA MECHANICAL: CALIFORNIA PLUMBING: CALIFORNIA ELECTRICAL: CALIFORNIA ENERGY: CALIFORNIA FIRE: CALIFORNIA GREEN BUILDING: ANY OTHER APPLICABLE LOCAL AND STATE LAWS AND REGULATIONS. CUPERTINO MUNICIPAL CODE: VICINITY MAP: A-00.01:COVER SHEET / PROPOSED SITE PLAN T-01:BOUNDARY AND TOPOGRAPHIC MAP DE-01:DEMOLITION PLAN A-01.01:PROPOSED FLOOR PLANS A-02.01:PROPOSED ELEVATIONS A-02.02: PROPOSED ELEVATIONS A-03.01: PROPOSED SECTIONS A-03.02:PROPOSED SECTION / STREET SCAPE ELEVATION A-04.01: FLOOR AREA DIAGRAM / EXTERIOR MATERIAL SCHEDULE DRAWING INDEX: 2022 EDITION 2022 EDITION 2022 EDITION 2022 EDITION 2022 EDITION 2022 EDITION 2022 EDITION 2022 EDITION NORTH BLDG 1ST FLOOR FOOTPRINT LINE PRIVATE OPEN SPACE PROPERTY LINE BLDG 2ND FLOOR FOOTPRINT LINE LEGEND: ATTACHED ADU OWNER:CHANDRA S 10095 ORANGE AVE, CUPERTINO, CA 95014 SCHANDRALABS@GMAIL.COM DESIGNER:AMS DESIGN (415) 254-1606 4010 MOORPARK AVE#101, SAN JOSE, CA 95117 AZADEH@AMSDESIGNLLP.COM STRUCTURAL:AMS DESIGN (415) 254 -2634 4010 MOORPARK AVE#101, SAN JOSE, CA 95117 ARMIN@AMSDESIGNLLP.COM T24 & ENERGY:- - - PROJECT CONTACT: PRIVACY VIEWSHEDS BLDG 2ND FLOOR FOOTPRINT LINE EXISTING 6' HEIGHT WOODEN FENCE FIRST FLOOR ROOF EAVE=210X1.6=336 LOT COVERAGE: 1ST FLOOR BLDG AREA (985+261)SQF TOTAL PORCH 25 SQF FIRST FLOOR ROOF EAVE 336 TOTAL %(1607/4007.70)X100 = 40% "E" BUILDING TO BE REMOVED:763 SQF "N" 1ST FLOOR LIVING AREA:985 SQF "N" 2ND FLOOR LIVING AREA:557 SQF "N" TOTAL LIVING:1542 SQF "N" GARAGE:261 SQF "N" TOTAL BUILDING:1803 SQF "N" PORCH:25 SQF ''N'' ATTACHED ADU:589 SQF NET LOT AREA :4007.70 SQF ''N'' FLOOR AREA RATIO (FAR):(1803/4007.70)X100=44.9% 2ND TO 1ST FLOOR (FAR):(557/(985+261))X100=44.7% BRA ND MANUFACTURER ITEM WEIGHT PACKA GE DIMENSIONS ITEM MODEL NUMBER COLOR MATERIAL SPECIA L FEA TURES SHADE MA TERIAL TYPE OF BULB DOUBLE CENTURY DOUBLE CENTURY 2.35 POUNDS 11.02 X 7.99 X 7.72 INCHES DCS-19021B 3000K A LUMINUM DIMMABLE GLA SS, A LUMINUM LED DETAILS EXTERIOR WALL LIGHT FIXTURE CUT SHEET 2ND FLOOR DARK SKY LIGHTING COMPLIANCE: Compliance with the Outdoor Lighting Requirements 19.102.040 i. Outdoor lighting must be fully shielded fixtures, directed downward to meet particular need away from adjacent properties and rights-of-ways to avoid light trespass. ii. Maximum light intensity on a site shall not exceed a maintained value of ten foot-candles, when measured at finished grade. iii. All light sources shall have a maintained correlated color temperature of 3,000 Kelvin or less. iv. All outdoor lighting must be fully extinguished or be motion sensor operated by 11:00 p.m. or when people are no longer present in exterior areas, with exceptions. v. Lighting design standards such as lighting fixtures must be of a design that complements the building and landscape design. vi. Prohibited lighting includes outdoor blinking, flashing, or rotating lights, flood lights, spotlights, and others as applicable. "E" BUILDING TO BE REMOVED:763 SQF 02/26/2024 S.B.PLN02 SMA