B-2017-2150 CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: CONTRACTOR. PERMIT NO:B-2017-2150
10131 EMPIRE AVE CUPERTINO,CA 95014-1204(326 24 055) REMODELWEST
CONSTRUCTION INC
SARATOGA,CA 95070
OWNER'S NAME: WOOD JAMES LAND CATHERINE LTRUSTEE DATE ISSUED'12/14/2017
OWNER'S PHONE.408-691-3703 PHONE NO:(408)257-4900
LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO'
License Class B Lic.#680463
Contractor REMODELWEST CONSTRUCTION INC Date 11/30/2019 X BLDG —ELECT _PLUMB
I hereby affirm that I am licensed under the provisions of Chapter 9(commencing —MECH X RESIDENTIAL_COMMERCIAL
with Section 7000)of Division 3 of the Business&Professions Code and that my
license is in full force and effect. JOB DESCRIPTION
MASTER BEDROOM AND HALLWAY BATHROOM REMODEL(214
I hereby affirm under penalty of perjury one of the following two declarations: S.F)
1, I have and will maintain a certificate of consent to self-insure for Worker's
Compensation,as provided for by Section 3700 of the Labor Code,for the
performance of the work for which this permit is issued.
"c�:a. I have and will maintain Worker's Compensation Insurance,as provided for by
Section 3700 of the Labor Code,for the performance of the work for which this
permit is issued. Sq.Ft Floor Area. Valuation.$0.00
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above
information is correct.I agree to comply with all city and county ordinances APN Number- Occupancy Type:
and state laws relating to building construction,and hereby authorize 326 24 055
representatives of this city to enter upon the above mentioned property for
inspection purposes. (We)agree to save indemnify and keep harmless the
City of Cupertino against liabilities,judgments,costs,and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED
may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR
Additionally,the applicant understands and will comply with all non-point
source regulations per e Cupertino Municipal Code,Section 9.18.6' 180 DAYS FROM LAST CALLED INSPECTION.
9 (A4t7_/(tl Ii9_ Issued by Phuong Devries
Signature
(ffY14S4./ D t
Date: 12/14/2017
OWNER BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for one of the RE-ROOFS:
following two reasons: All roofs shall be inspected prior to any roofing material being installed.If a roof is
r. I,as owner of the property,or my employees with wages as their sole installed without first obtaining an inspection,I agree to remove all new materials for
compensation,will do the work,and the structure is not intended or offered for inspection.
sale(Sec.7044,Business&Professions Code)
2. I,as owner of the property,am exclusively contracting with licensed Signature of Applicant:
contractors to construct the project(Sec.7044,Business&Professions Code). Date:
1 hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER
1. I have and will maintain a Certificate of Consent to self-insure for Worker's
Compensation,as provided for by Section 3700 of the Labor Code,for the
performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE
2. I have and will maintain Worker's Compensation Insurance,as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the
Section 3700 of the Labor Code,for the performance of the work for which this California Health&Safety Code,Sections 25505,25533,and 25534. I will
maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the
permit is issued.
3. I certify that in the performance of the work for which this permit is issued,I Health&Safety Code,Section 25532(a)should I store or handle hazardous
material. Additionally,should I use equipment or devices which emit hazardous
shall not employ any person in any manner so as to become subject to the air contaminants as defined by the Bay Area Air Quality Management District I
Worker's Compensation laws of California. If,after making this certificate of will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and
exemption,I become subject to the Worker's Compensation provisions of the the Health&Safety Code,Sections 25505,25533,and 25534.
Labor Code,I must forthwith comply with such provisions or this permit shall
be deemed revoked. Owner or authorized agent:��icL.40"`
APPLICANT CERTIFICATION Date:1j/,q f
I certify that I have read this application and state that the above information is / ONSTRUCTION LENDING AGENCY
correct.I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agency for the performance
relating to building construction,and hereby authorize representatives of this city of work's for which this permit is issued(Sec.3097 Civ C.)
to enter upon the above mentioned property for inspection purposes. (We)agree Lender's Name
to save indemnify and keep harmless the City of Cupertino against liabilities, Lender's Address
judgments,costs,and expenses which may accrue against said City in
consequence of the granting of this permit. Additionally,the applicant understands ARCHITECT'S DECLARATION
and will comply with all non-point source regulations per the Cupertino Municipal I understand my plans shall be used as public records.
Code,Section 9.18.
Licensed
Signature Date Professional
\\ CONSTRUCTION PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT a BUILDING DIVISION
‘°:>.4.:t.I 10300 TORRE AVENUE a CUPERTINO,CA 95014-3255
4'4. (408)777-3228 FAX(408)777-3333 a buildinqAoupertino:orqtB,-ZO}. 1 f Sb
CUPERTINO'
❑NEW CONSTRUCTION 0 ADDITION ALTERATION/TI ❑ REVISION/DEFERRED ORIGINAL PERMIT#
PROJECT ADDRESS10131 Empire Avenue,Cupertino,CA 95014 APN# 326-24-055
OWNER NAMEJames and Cathy Wood PHONE 408-691-3703 E-MAIL timstevens25@yahoo.com
STREET ADDRESS. 10131 Empire Avenue CITY, STATE,ZIP Cupertino,CA 95014 FAX
CONTACT NAME Tara Rasmussen'. PHONE 408-257-4900E-MAIL tarar@remodelwest.com
STREET ADDRESS 12333 Saratoga Sunnyvale Rd CITY,STATE,ZIP Saratoga,CA 95070 FAX
❑OWNER 0 OWNER-BUILDER 0 OWNER AGENT 1CONTRACTOR 0 CONTRACTOR AGENT 0 ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑TENANT
CONTRACTOR NAME William Reid LICENSE NUMBER 680463 LICENSE TYPE B BUS.LIC# 454351 1 21 0
COMPANY NAME. RemodelWest Construction Inc. E breid@remodelwest.com FAX
STREET ADDRESS 12333 Saratoga Sunnyvale Road CITY,STATE,ZIP Saratoga,Ca. 95070 PHONE 408- 257-4900
ARCHITECT/ENGINEERNAME .LICENSE NUMBER BUS.LIC.#
COMPANY NAME E-MAIL FAX
STREET ADDRESS CITY,STATE,ZIP PHONE
DESCRIPTION OF WORK
I)Remodel Master Bath Room 2)Remodel Bathroom#1
EXISTING USE PROPOSED USE CONSTR.TYPE #STORIES. USE TYPE OCC. SQ.FT. VALUATION($)
R1-7.5 R1-7.5 VB 2
EXISTG NEW FLOOR DEMO TOTAL
AREA 2564.06 AREA AREA -- NET AREA 2564.06
BATHROOM KITCHEN OTHER
REMODEL AREA 200Sf REMODEL AREA 0. REMODEL AREA 0
PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA* 0
IiiTTACH
444.69sfACH A
#DWELLING UNITS: IS A SECOND UNIT ❑ S SECOND STORY ❑ .S
1 BEING ADDED. ADDITION. 17:4,
O
PRE-APPLICATION ❑ S IF YES,PROVIDE COPY OF IS TIIE BLDG AN ❑ S ":!5•1
®B — - TO VALUUATTIIONN:
PLANNING ADPL# O PLANNING APPROVAL LETTER EICHLERHOME? • I ' 1 1 1V/ Il y.
By my signature below,I certify to each of the following: I am the property owner or authorized agent toiact on the.roperty owner's behalf I have read this
application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the above-identified property for inspection purposes.
Signature of Applicant/Agent: /e2.4Cri y Date: 11/30/17
SUPPLEMENTAL INFORMATION REQUIRED € rIa � _
New SFD or Multifamily dwellings: Apply for demolition permit for '' .1-7:.:`-'--7-.-:=4:-:1,,,:..7;- r i={ I.TEZIv -tJJA W ,,,,,711.
existing building(s). Demolition permit is required prior to issuance of building -17: �1,- �rAi REW
permit for new building. 4:
Ti PImuc WIC
Commercial Bldgs: Provide a completed Hazardous Materials DisclosureI formif any Hazardous Materials are being used as part of this project. Ilae — -
_Copy of Planning Approval Letter or Meeting with Planning prior. to 1t AJOR a AI AI€ I z l =r
submittal of Building Permit application.
14 rIt{?rra3EI A TI• EAGTII
BldgApp_2011.doc revised 06/21/11
Phuong Devries
12/14/17
The plan indicates the installation of a Whirlpool Bathtub. Indicate the following installation
requirements as plumbing plan notes: (CPC 409)
D%DWKWXEVDQGZKLUOSRROEDWKWXEVVKDOOKDYHDZDVWHRXWOHWDQGIL[WXUHWDLOSLHFHQRWOHVVWKDQ
1.5 inches in diameter. (CPC 409.2)
E$UHPRYDEOHSDQHORIVXIILFLHQWGLPHQVLRQVKDOOEHSURYLGHGWRDFFHVVDQGUHPRYHWKHSXPS
(CPC 409.6)
F:KLUOSRROSXPSDFFHVVORFDWHGLQWKHFUDZOVSDFHVKDOOEHORFDWHGQRWPRUHWKDQIHHWIURP
an access door, trap door, or crawl hole.
G7KHFLUFXODWLRQSXPSVKDOOEHORFDWHGDERYHWKHFURZQZHLURIWKHWUDS&3&
H7KHSXPSDQGFLUFXODWLRQSLSLQJVKDOOEHVHOIGUDLQLQJWRPLQLPL]HZDWHUUHWHQWLRQ&3&
409.6)
I6XFWLRQILWWLQJVRQZKLUOSRROEDWKVVKDOOEHOLVWHGLQDFFRUGDQFHZLWK$60($&6$
B45.10.
J)L[WXUHVKDYLQJFRQFHDOHGVOLSMRLQWFRQQHFWLRQVVKDOOEHSURYLGHGZLWKDQDFFHVVSDQHORU
utility space not less than 12 inches in its least dimension and so arranged without obstructions
as to make such connections accessible for inspection and repair. (CPC 402.10)
Phuong Devries
12/14/17
PLUMBING:
All piping ¾ inch or more in diameter and all hot water pipes associated with a
recirculation system must be insulated with min. 1-inch thick insulation. Existing
inaccessible piping does not require insulation [CEnerC 150.0(j)2].
Water closets shall not exceed 1.28 gallons per flush, showerheads shall not
exceed 2.0 GPM and new lavatory faucets shall not exceed 1.2 GPM at 60 PSI. [CPC
407.2, 408.2 & 411.2]
Water closet and bidets require a minimum 15 inches of clearance from the center
line of the bowl to each side, and 24 inches of clearance from the front edge of
the bowl [CPC 402.5].
Lavatory sinks require a minimum of 24 inches front clearance [CPC 402.5]
Showers require a minimum 2 inch drain and trap [CPC Table 702.1].
All shower compartments shall have a minimum finished interior of 1024 square
inches and shall be capable of encompassing a 30 inch diameter circle [CPC
408.6].The curb may encroach on these size requirements. All surfaces shall be
waterproof up to 72 inches above the drain inlet [CRC R307.2]. Thresholds shall be
of sufficient width to accommodate a minimum 22 inch clear egress opening from the
shower [CPC 408.5].
Safety glass (tempered or laminated) is required for all glass shower doors and
partitions and for windows in walls facing the tub or shower and located less than 60
inches above the standing surface of the tub/shower and within 60 inches horizontally
[CRC R308.4.1&5].
The maximum water temperature to a shower or tub/shower combination is 120F.
The water heater thermostat cannot be used as the control for this temperature.
Valves shall provide scald and thermal shock protection, and be pressure-balanced,
thermostatic, or combination pressure-balanced/thermostatic mixing in
accordance with ASSE 1016 or ASME A112.18.1/CSA B125.1. [CPC 408.3]
ELECTRICAL:
All installed lighting shall be high efficacy. [CEnerC150.0(k)1A]
At least one light shall be controlled by a vacancy sensor (a
manual-on, automatic-off occupancy sensor). [CEnerC 150.0(k)2A]
All receptacle outlets in bathrooms shall be GFCI protected [CEC
210.8A1].
All receptacle outlets in bathrooms shall be tamper resistant [CEC
406.12A].
When a bathtub or shower stall is in an area not technically
considered a bathroom (by the definitions in the electrical code),
receptacles within 6 ft. of the
tub/shower stall must be GFCI- protected. [CEC210.8A9].
A receptacle outlet is required within 3 feet of each wash basin
location. It may be on the wall, or an adjacent partition, or on the
face or side of the cabinet not
more than 12 inches below the top of the basin [CEC 210.52D].
Receptacles cannot be face-up in a vanity surface; listed pop-up
receptacles are allowed [CEC 406.5E & 210.52D].
A minimum of one 20-amp circuit is required for the receptacles in
the bathroom(s). This circuit can have no other outlets, including
lights [CEC 210.11C3]. If a
20-amp circuit serves only one bathroom, lights and fans can be on
the same circuit with the receptacles in that bathroom [CEC
210.11C3 exception].
Hydro-massage tubs require an individual (dedicated) branch
circuit and readily accessible GFCI protection [CEC 680.71]. An
access door is required and must be
large enough to remove the motor and pump. Cord-connected
equipment must have the receptacle facing the opening and be no
more than one foot behind the
access hatch [CEC 680.73].
Recessed light fixtures in shower enclosures must be listed for a
damp or wet location [CEC 410.10A]
Pendant light fixtures, track lights, and paddle fans shall not be
installed lower than 8 feet above the flood-level rim of a tub,
including the area 3 feet past the edge of
the tub [CEC 410.10D].
Electrical panels shall not be installed in bathrooms [CEC
240.24E].
Switches and receptacles are not allowed in bathtub or shower
spaces [CEC 404.4C & 406.9C].
Phuong Devries
12/14/17
Phuong Devries
12/14/17