Loading...
14080096 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10360 STERN AVE CONTRACTOR:SOLARCITY PERMIT NO: 14080096 OWNER'S NAME: VARNAVA BORYS S AND TETYANA 1 TRU 3055 CLEARVIEW WAY DATE ISSUED:08/13/2014 OWNER'S PHONE: 4088218722 SAN MATEO,CA 94402 PHONE NO:(650)638-1028 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL E] COMMERCIAL INSTALL 15 PANEL PV SYSTEM ON SFDWL ROOFTOP License Class L 10' —C4 4 Lic.# ' J0 3.82KW Contractor S��lq r C, -) Date I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$9000 l have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:37514028.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.l agree to comply with all city and county ordinances and state laws relating WITHIN F PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYRO ST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the granting of this permit. A ditionally, applicant understands and will comply Issued by: Date: with all non-point sourc regulatigtts r the CC ertino Municipal Code,Section 9.18. i _ ---- RE-ROOFS: Signature Date g All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ o' OWNER-BUILDER DECLARATION G Signature of Applicant: Date: I hereby affirm that 1 am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). l have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will 1 hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain aCertificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cuper ino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25 5,25533,od 25534. Section 3700 of the Labor Code,for theerformance of the work for which this p Owner or authorized agent: i'F� Dater`t )3 117 permit is issued. I certify that in the performance of the work for which this permit is issued,1 shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,1 /-CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION �/ COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION ,J (•� 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 S( CUPERTINO (408)777-3228• FAX(408)777-3333•building(Dcupertino.org 1 U PROJECT ADDRESS O ,� � AVL APN# 73 �` OWNERNAME �^ o �C J� 1 f A /► ` IAV ^ P ONE J E-MAIL U rl.� -1 v �l�N I^� 04"- -Z -��2 Z STREET ADDRESS 03 6 lo w I '� CICTYTATE,ZIPTt�'^ c'-_0q-_0q FAX CONTACT NAMEPHONE V fEE MAIL t�9�1 v C_ SC04 cf ._ q ld 0 S� j'e t, C' ✓`l STREET ADDRESS CITY STATE ZIP FAX STC`'A- C(�P �G,cJ/rL�_ j1�-!L.C l r�'f �9 `�'-f�1 U ❑OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT �r CONTRACTOR 1:1 CONTRACTOR AGENT ❑ ARCHITECT El ENGINEER ❑ DEVELOPER El TENANT CONTRACTOR NAME LICENSI�NUM LICENSE TYPE BUS.LIC# Sv L�42 C l rte'( � C t c�� COMPANY NAME E-MALL •� FAX _ STREET OcS ESC mo i` '( �._ Y, ATE,ZIP ^ J cl q qc) Z PHONE- ARCHITE CT/ENGINEER NAME V LICENSE NUMBER V BUS.LTC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF 0e<DorDuplex ❑ Minh-Famlly PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ No FLOOD ZONE ❑ Yes ❑ No (;'SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER. FOR SOLAR PANELS: NUMBER OF PANELS/UMTS: #KILOWATTS: L TOTAL V ALUATION: DESCRIPTION OF WORK ! f r\ t,� L_U<tf�`V``��` M <6 Z/q Pr7o RECEIVED B By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the pro read this application and the information I have provided is correct. 1 have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating t it ng construction. I authorize representatives of Cupertino to enter the above-identified property for inspection purposes. (-2-Signature of Applicant/Agent: Date: j� �{j � - / /q SUPPL ENTAL INFORMATION REQUIRED OFFICE USE ONLY W ❑ OVER-THE-COUNTER F" ❑ EXPRESS U U W ❑ STANDARD x U a ❑ LARGE c. ❑ MAJOR PVApp 2012.doc revised 06/20/12 CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION WPERMIT DDRESS: 10360 stern ave DATE: 08/13/2014 REVIEWED BY: Mendez PN: BP#: 'VALUATION: $9,000 PE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex PENTAMATION SOLAR-RES USE: PERMIT TYPE: WORK install 15panel pv system on sfdwl rooftop 3.82kw SCOPE Ll Ll NOTE: This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc.). These ees are based on the prelimina information available and are only an estimate. Contact the De t or addn'l info. FEE ITEMS (lee Resolution 11-053 Eff 7/1,13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 # Alternative Energy System Suppl. PC Fee: Q Reg. 0 OT 1 0.0 1 hrs $0.00 $236.00 1PHOTOVRES Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:Q Reg. 0 OTT-O.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 0 Work Without Permit? 0 Yes 0 No $0.00 0 Advanced Planning Fee: $0.00 Select a Non-Residential 0 Building or Structure 0 i Strom Motion Fee: 1BSEISMICR $1.17 Select an Administrative Item Bldg,Stds Commission Fee: 1BCBSC $1.001 1 SUBTOTALS: $2.17 $236.00 TOTAL FEE: 1 $238.17 Revised: 07/1012014 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING FLASHING WILL BE PAINTED TO MATCH EXTERIOR AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, BLDG BUILDING A SIGN WILL BE PROVIDED WARNING OF THE CONIC CONCRETE HAZARDS PER ART. 690.17. RECEIVE D DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE 1, EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY (E) EXISTING PHASE AND SYSTEM PER ART. 210.5. AUG 13 2014 EMT ELECTRICAL METALLIC TUBING 3. A NATIONALLY—RECOGNIZED TESTING GALV GALVANIZED LABORATORY SHALL LIST ALL EQUIPMENT IN '1 GEC GROUNDING ELECTRODE CONDUCTOR COMPLIANCE WITH ART. 110.3. BY GND GROUND 4. CIRCUITS OVER 250V TO GROUND SHALL HDG HOT DIPPED GALVANIZED COMPLY WITH ART. 250.97, 250.92(B) I CURRENT 5. DC CONDUCTORS EITHER DO NOT ENTER Imp CURRENT AT MAX POWER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR Isc SHORT CIRCUIT CURRENT ENCLOSURES TO THE FIRST ACCESSIBLE DC COMMUNITY DEVEL0PMENT DEPARTMENT ` ' kVA KILOVOLT AMPERE DISCONNECTING MEANS PER ART. 690.31(E). BUILDING DIVISION-CUPERTINO iWpT• kW KILOWATT 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN �•' LBW LOAD BEARING WALL RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY APT-c�i OVED ` MIN MINIMUM UL LISTING. This set of plans and specifica~ions Iv1UST ba keit at the (N) NEW 7. MODULE FRAMES SHALL BE GROUNDED AT THE Job site during Construction. It is unlawful to mslce any NEUT NEUTRAL UL—LISTED LOCATION PROVIDED BY THE changes or alterations on same,or to deviate >�G• DF•pT• NTS NOT TO SCALE MANUFACTURER USING UL LISTED GROUNDING therefrom,without a B OC ON CENTER HARDWARE. approval fror-n the Building Gfi`icial. PL PROPERTY LINE 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE inA stamping r it plan and sr cMcations SHALL NOT is held to permit or POI POINT OF INTERCONNECTION BONDED WITH EQUIPMENT GROUND CONDUCTORS AND o.an ` `'' =I-Oval of the vioiaticn Y provisions of PV PHOTOVOLTAIC GROUNDED AT THE MAIN ELECTRIC PANEL. ity Ordinance or Slate Law. SCH SCHEDULE 9. THE DC GROUNDING ELECTRODE CONDUCTOR BY _ 53 SS STAINLESS STEEL SHALL BE SIZED ACCORDING TO ART. 250.166(B) & p_ STC STANDARD TESTING CONDITIONS 690.47. (;vr TYP TYPICAL ,,IT NO. UPS UNINTERRUPTIBLE POWER SUPPLY �� O V VOLT Vmp VOLTAGE AT MAX POWER VOLTAGE AT OPEN CIRCUIT W WATT VICINITY MAP INDEX W 3R NEMA 3R, RAINTIGHT P11 COVER SHEET P 12 SITE PLAN • PV3 STRUCTURAL VIEWS IFT CALCUL��I1QQ����.,, EE LINE DIA6RfMG ERI ONO LICENSE GENERAL NOTES I Ut Attached Suilding Department CA # 888104 1. THIS SYSTEM IS GRID—INTERTIED VIA A AM1 20� C-10 UL—LISTED POWER—CONDITIONING INVERTER. 4I '" '� 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. �EVIEWEG FQf? CODE 3. SOLAR MOUNTING FRAMES ARE TO BE r NOF GROUNDED. 4. ALL WORK TO BE DONE TO THE 2013 Reviewed By ��,,. MODULE GROUNDING METHOD: ZEP SOLAR CALIFORNIA BUILDING CODE AND THE 2013 AHJ: Cupertino CALIFORNIA RESIDENTIAL CODE. REV BY DATE COMMENTS 5. ALL ELECTRICAL WORK SHALL COMPLY WITH AME DATE COMMENTS THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY ItEVA N THE 2013 CALIFORNIA ELECTRIC CODE. UTILITY: Pacific Gas and Electric Company CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBERJ13-9503166 00 PREMISE OVWR: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE VARNAVA, BORYS VARNAVA RESIDENCE John Coker ����•. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSML ►� 'SolarC�ty. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile FTTIe 10360 STERN AVE 3.825 KW PV ARRAY ,, • PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: C U P E R TI N 0, CA 95014 THE SALE AND USE OF THE RESPECTIVE (15) Advantage Module 64L 3055 CIearvier Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER PAGE NAME SHEET: REV: DATE Son 402 T:(650)63e—T0Mateo, CA 90)638-1029 PERMISSION of SOLARCITY INC. SOLAREDGE SE380OA—US—ZB—U 4088218722 COVER SHEET PV 1 7/2/2014 (Bea)-SOL-CITY(765-2489)www.ealorcity.ao„ PITCH: 23 ARRAY PITCH:23 MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Flat Cement Tile STORY: 2 Stories �3 PITCH: 23 ARRAY PITCH:23 MP2 AZIMUTH:90 ARRAY AZIMUTH:90 MATERIAL: Flat Cement Tile STORY: 2 Stories 0 J / / / / / Front Of House / / 0/1I// LEGEND s (E) UTILITY METER & WARNING LABEL �I INVERTER W/ INTEGRATED DC DISCO z1i I m� & WARNING LABELS 4�1!d _ I DC DISCONNECT & WARNING LABELS 0 CsI CD \ AC DISCONNECT & WARNING LABELS (E) DRIVEWAY I _; i a ; ^\ \\ DC JUNC110N/COMBINER BOX & LABELS I , D I I — _3'Fire Setback / \ J61\ �. .' MP1 \��, DISTRIBUTION PANEL & LABELS (D - -- ,� xA,n \ LOAD CENTER & WARNING LABELS M '" TED PV SYSQJRERTINO o s l FF wilding Department 0 ice. L,NOCATIONSIT �{Q IT RfJtr NIEt EX; A NCE 0Ei�0DI�Q3�; ( i\CE n G) I;`�I IN'-'tfkidl'"MLR MENL�ASHE�'�' Qj v L-,J rp Q TOTAL ARRAY AREA (SF): 270 SITE PLAN NScale: 1/8" = 1' TOTAL ROOF AREA (SF): 2534 w E TOTAL ARRAY AREA IS a 10.65 0 1' 8' 16' PERCENT OF TOTAL ROOF AREA s CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J[3-9503166 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BEUSED FOR THE VARNAVA, BORYS VARNAVA RESIDENCE John Coker _., �C�ty. BENEFIT OF ANYONE EXCEPT SOLARGTY INC., MOUNTING SYSTEM: �.,�5 y. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile File 10360 STERN AVE 3.825 KW PV ARRAY ;;Sola1 PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES CU P E R TI N 0, CA 95014 —,IeLl THE SALE AND USE OF THE RESPECTIVE (15) Advantage Module 3055 Ctearview way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER PAGE NAME SHS: REV-. DATE T:(650)Son Mae CF.A 9438- 1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE380OA-US-ZB-U 4088218722 SITE PLAN PV 2 7/2/2014 (888)-SCI-CITY(765-2489)nn.solarcity.com l f l S1 S1 1 +e n 10'-5" 1'-3 (E) LBW 14'-4" (E) LBW 70, A SIDE VIEW OF MP1 NTS SIDE VIEW OF MP2 NTS B MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 24" LANDSCAPE 64" 24" PORTRAIT 48" 19" PORTRAIT 48" 19" RAFTER 2x6 @ 16" OC ROOF AZI 180 PITCH 23 STORIES: 2RAFTER 2x6 @ 16" OC ROOF AZI 90 PITCH 23 STORIES: 2 ARRAY AZI 180 PITCH 23 ARRAY AZI 90 PITCH 23 C.J. 2x6 @24" OC Flat Cement Tile C•3. 2x6 @24" OC Flat Cement Tile INSTALLATION ORDER " DIA THREADED STUD REMOVE TILE, LOCATE & MARK & NUT (1) RAFTER LOCATION.PLACE STANDOFF BASE & DRILL PILOT HOLES. ZEP LEVELING FOOT ------ ------ ----------- ZEP TOP ARM 2) CLEAN PAPER AROUND PILOT HOLE. ZEP ANTI-ROTATION PLATE (6) M10 BOLTS 5 SEAL PILOT HOLES AND BOTTOM OF MOUNTING BASE ( ) (3) STANDOFF WITH POLYURETHANE (E) TILE (1) SEALANT. (E) ROOF DECKING 4) LAG STANDOFF BASE INTO RAFTER. (E) RAFTER 941 (4) (2) V (3) PLACE FLASHING AND ATTACH + '. ? ��������� DIA LAG BOLTIJ 5) I! " y SEALING SPACER WITH SINGLE BOLT. Building C}epar'rmenP (2AUG- " EMBED, MIN) Ie~ (6) PLACE ZEP BAR. THEN LEVELING FOOT WITH BOLT &SWASHER. 1 201 REVIEWED FC)R COIr1E CCMPL.IANC% S1 STANDOFF :�Zlev iewed BY _I ', Scale: 1 1/2" = 1' CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: J B-9503166 00 CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MDUNTING SYSTEM: VARNAVA, ORYS VARNAVA RESIDENCE John Coker SolarCity. 4 NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile FTile 10360 STERN AVE 3.825 KW PV ARRAY I'i,, • PART TO OTHERS OUTSIDE THE RECIPIENTS MoouLEs CUPERTINO, CA 95014 ORGANIZATION, EXCEPT IN CONNECTION WITH TsVt ajCA_ THE SALE AND USE OF THE RESPECTIVE (15) Advantage Module 3055 gearvier Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN 94402 INVERTER PAGE NAME S.SHREV: DAA' T:(650)Son Ma28 C(650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE380OA-US-ZB-U 4088218722 STRUCTURAL VIEWS PV 3 7/2/2014 (888)-SOL-CITY(765-2489)nn.sdardty.com UPLIFT CALCULATIONS _. ----- - 07.OL2014 ="::�o�arCity TkMo - � vee Structural Desian Software URFlat E oaf 77 PV System Module ait P11 Module VNdth 39" Standoff_. 'ttuh I-lardlrrare SM Tile Ground Snow Load P9 0.0F TaNe 7-1 Snow PV OA ASCE. T.4=1 VVtnd Code ASCE 740 easrc titIlnd speed v 110• 26 Sr1A IW�71 lRI�11 F2.3fiA4&WC W8 %r Effealve VAnd Area 1 Module A 17.6 sf IBC 1509.7.1 VAnd Pressure F oalre Kz 0.95 Table 303-1 and Dhedionallty Factor Kd 0.85 Section 26:6-1- Velocft Prime Vh qh=0.00256(Kz)(Kzt)(Kd)M2) Equate 30.3-1 24J Ext Pressure Cae6ldent AW) GCp -0.80- Ap.3&A-20INC"R lAWhA Pressure p= h 30.4 i Wind Presore Ommdown 16.0 PSIF Max ANaWrable Standoff S Lanclsq e Vii:' ►�- T`� tit. Standoff Lan CP'V Dead LW-PV CUPER 1rINN Building Department M'RMCapaT-allow 446 IN M - - i Max Avowable StandoffSparing Portrait - 48" l7 13 2014 Standoff ... ratlon Po�ait Not F_, CODE COMPLIANCE PV Assem _ Dead Load W-PV 3 psf _ - _ __. t - t �utt3wlyd y 7� C, afi Stand�lf T-allow 446 IN ,11 CONFIDENTIAL- THE INFORMATION HEREIN ruMeE� J13-9503166 0 0 PREIISE OMM DPSCRPWW DESIGN:- CONTAINED ESIGN: . , • BENEFIT O SHALL ANYONE NOT BET SO FOR THEVARNAVA, BORYS VARNAVA RESIDENCE John Coker �'• SolarC�ty. BENEFIT OF ANYONE EXCEPT SD FOR T INC., MOUNTING SYSTEIL NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile File 10360 STERN AVE 3.825 KW PV ARRAY it PART TO OTHERS EXCEPT IN ON RECECTION WT MODu.Es CUPERTINO, CA 95014 3M aa�way ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (15) Advantage Module SOLARCITY EQUIPMENT,WITHOUT THE WRITTEN PAGE NAME SHEET' RE.. DATE San T:(650)838 We CA 94402 8-1029 PERMISSION OF SOLARCITY INC' SOLAREDGE SE3800A—US—ZB—U 4088218722 UPLIFT CALCULATIONS PV 4 7/2/2014 (669)-SOL-CITY(1=_2�)www.wkrdtyoan GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND N GEC TO N GROUND ROD Panel Number:MC2040MB120OF Inv 1: DC Ungrounded _ )AdvantageCA # 888104 ( � ( � Meter Number:ING10066748421109 rINV —(1 )SOLAREDGE 2400V, 97.57o;ZBw/Unlfed Disco and ZB, AFCI —Q5Modue;255W, Poly, 60cell, Bick Frame, White Bcksht, ZEP C-10 AT PANEL WITH IRREVERSIBLE CRIMP Underground Service Entrance Voc: 37.7 Vpmax: 30.2 l,sc AND.IMp ARE SHOWN IN THE DC STRINGS IDENTIFIER (E) 200A CENTER—FED MAIN SERVICE PANEL E 200A/2P MAIN CIRCUIT BREAKER Inverter 1 200A/2P 3 SOLAREDGE SE3800A—US—ZB—U (E) LOADS zaov SolarCity L1 N 2 A I 20A/2P EGG a IN EDC- ---' DC- A ——————————————————————————————————————————————— GEC ———T I String(s)Of 15 On MP1,MPDG DC- CGND —— ——————————————————————————— --—— —_ G---------------- --- � I I I N I I EGCIGEC — Z Z --- GEC --� TO 120/240V SINGLE PHASE UTILITY SERVICE I I I I Voc* — "".` VOC AT MIN TEMP OTT1 )SIEMENS Q220 PV BACKFEED BREAKER (1 darCityy 4 STRING JUNCTION BOX 1 ( Breaker,,t20A/2P, 2 Spaces AC 2x2 SIR GS, UNFUSED, GROUNDED DC —0 )Ground Rod; 5/8' x 8', Copper PV (S)SOLAREox ptimOer, 30OZS PowerBox ptimizer, 300W, H4, DC to DC, ZEP 1 WG #10, THWN-2, Black 1 AWG /10, THWN-2, Black Voc* =500 VDC ISC =15 ADC (2)AWG/10, Voc -VDC -Isc =15 ADC O�(1 )AWG y10, THWN-2, Red O (1 )AWG/10, THWN-2, Red Vmp =350 VDC Imp=10.79 ADC O (1 )AWG/10,� er EGC Vm bxc uio=11.79 ADC (i )AWG /10, THWN-2, White NEUTRAL VmP =240 VAC Imp=15.83AAC (1 )AWG/10 THWN-2,_Green EGC. . .—(1 )Conduit_Kit; 3 4'.EMT. . . �` f �ll(j.ln . . . . . . .-.(1)AWG /8,.TIiWN-2,_Green. . . EGC/GEC.—.(1 / I ! k onduit.Kit;.3/4'_FAIT AUG 13 2014 Reviewed Cy CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBERPREMISE OWNER: DESCRIPTION: DESIGN: / JB-9503166 00 k CONTAINEDBENEFIT O SHALL NOT BE USED FOR THE VARNAVA, BORYS VARNAVA RESIDENCE John Coker ;So�arCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �-., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile FTile 10360 STERN AVE 3.825 KW PV ARRAY PART TO OTHERS OUTSIDE THE REGPIENTS MODULES CUPERTINO, CA 95014 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (15) Advantage Module 3055 gearview Way PAGE NAME SHEER REV DATE Son Mateo,CA 94402 SOLARGTY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION of SOLARGTY INC. SOLAREDGE # SE380OA—US—ZB—U 4088218722 THREE LINE DIAGRAM PV 5 7/2/2014 (888)-SOL-CITY(765-2489)www.solarcity.com Label Location: Label Location: Label Location: WARNING:PHOTOVOLTAIC POWER SOURCE D Per Code: PV SYSTECM WARNING _ Code: CRC R331.2DISCONNET FOR Fi FGTRIC SHOCK HAZARD 690.35(F) UTILITY OPERATION THE DC CONDUCTORS OF THlS Label Location: PHOTOVOLTAIC SYSTEM ARE • BE USED WHEN PHOTOVOLTAIC DC UNGROUNDED ANDINVERTERIS DISCONNECT MAY BE ENERGIZED UNGROUNDED CEC .•0 .14.C.2 Label Location: WARNING '._ Code: _ ELECTRIC SHOCK HAZARD CEC .� '• Location: • DO NOT TOUCH TERMINALS MAXIMUM POWER TERMINALS ON BOTH LINE AND POINT CURRENT(Imp)_APer Code: LOAD SIDES MAY BE ENERGIZED MAXIMUM POWER- IN THE OPEN POSITION POINT VOLTAGE(Vmp)_VCEC • MAXIMUM SYSTEM_V VOLTAGE(Voc) SHORT-CIRCUIT CURRENT(Isc) A Label . _ WARNING (POI)Code:Per CEC 705.12.D.7 INVERTER OUTPUT CONNECTION Label Location: DO NOT RELOCATE WARNING THIS OVERCURRENT Code:Per DEVICE ELECTRICALSHOCK HAZARD 690.17 DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES Z. ENERGIZED IN THE OPEN POSITIONLabel L• • DC VOLTAGE IS PHOTOVOLTAIC POINT OF '• ALWAYS PRESENT WHEN INTERCONNECTION Per SOLAR MODULES ARE WARNING: ELECTRIC SHOCK ••� 690.17 EXPOSED TO SUNLIGHT HAZARD.DO NOT TOUCH TERMINALS.TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION.FOR SERVICE Label Location: DE ENERGIZE BOTH SOURCE WARNING AND MAIN BREAKER. Per Code: PV POWER SOURCE MAXIMUM AC ELECTRIC SHOCK HAZARD 690.5(C) OPERATING CURRENT _ A IF A GROUND FAULT IS INDICATEDMAXIMUM AC NORMALLY GROUNDED _ V CONDUCTORS MAY BE OPERATING VOLTAGE UNGROUNDED AND ENERGIZED <; CUPERTWicSuilding Label • •Label lu <,..,.. Location: CAUTION PHOTOVOLTAIC AC _ '• Per Code: ' "" DISCONNECTCode: P CIRCUIOT IS BACKFEDM 690.64.B.4 • • • .•0 • ed By. (D): Distribution Panel Conduit(DC): DC Disconnect (IC): Interior Run Label Location: Label Location: (INV): Inverter With Integrated DC Disconnect MAXIMUM AC q • CAUTION •I) (LC): Load Center OPERATING CURRENT Per •.-: Per Code: MAXIMUM ACCEC 690.54 SECOND SOURCE ISCEC 705.12.D.7 (M): Utility Meter OPERATING VOLTAGE _ V PHOTOVOLTAIC SYSTEM (POI): Point ofInterconnection 3055 Oeaview Way • . r Egg L 4012111109011 6 San Mateo,CA ., SCCA Label Set (888)-SOL-CrrY(765-2489)www.solarcity.com a• 41115,101011111. I . I - • so I a r ' • @ ! so I a r " • • T SolarEdge Power Optimizer Module Add-On for North America P300 / P350 / P400 SolarEdge Power Optimizer P300P350 P400 Module Add-On For North America (for 60 cell PV ,for 72-cell PV (for 96-cell PV modules) modules) modules) "P"T P300 / P350 / P400 • Rated Input DC Powerlu 300 350 400 W ..A.b...... �..im m In ut Volta.e...o.....I.... ..........r... ..........48........ ........ ........ .........80........ ....Vdc Absolute az u p g (V cat owes[tempera.. e) 60 MPPT Operating Range 8-a8 ...8-60.....................8-80.,__...., Vdc • MaximumShort fJrcui[Current(Isc) 10 . Adc ........ .. ... .... .. ... ... .... .... ... ._. Maximum DC Input Current 1.2.5 Adc Maximum Efficiency Weighted Efficiency 98.8 % Overvolta a Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) _ Maximum Output Current 15 Adc ....................................................................................................... ..........................._.......... ............. Maximum Output Voltage 60 Vdc • OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part1S Class 8,IEC63000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 RoHS Yes INSTALLATION SPECIFICATIONS _ Maximum Allowed System Voltage 1000 Vdc Dimensions(W xlx H) 141 x 212 x 40.5/S.SS x 8.34 x 1.59 mm/in ......ensi........................................._.........._._............._....._....................................................._.......... ............. Weight(incI dingcablesl..................................._.........................._.,............950/2:1.......... .Br/lb.... u ................. ..... . Input Connector MC4/Amphenol/T yoo Output Wire Type/Connector Double Insulated;Amphenol Output Wire Length........................................................095/30........I.......................L2/.3.9............ m/ft ......... ............ Operadng Temperature Range 40-+85/-40-+185 .C/'F ............................................................................................................................................................... ............. Protection Rating 'PISS/NEMA4 Relative Humidity0-100 % ..................................................................................... _ . LUPE RTINO �^n,rm stc w...a rro moa.�e.naa,i:a�o r.•sx w`«or.,�.wed PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE THREE E,- Building Cepartment INVERTER 208V PV power optimization at the module-level Minimum string Length(Ppweropdmaer5) g 10 1 f �j�j 1 2014 _.... Up to 25%more energy Maximum Stnng Length(Po er Optimizers) 25 25 50� �--� ....... .......... ...... . ..... ............... ............ ........ ... Maximum Power per String 5250 1275 w 6000 0 — Superior efficiency 99.5% P B Pnry( ) ....................................................................................................................................................g.. 1....C..,1.n..�.... L s.� r'�r�r�C f 1� r�y Parallel Strings of Different Lengths.. Onentatlons Yes f\ yll l.,.YVE.D f OR GODE `��f r-Ll���� — Mitiga[esalltypesofmodulemismatchlosses,frommanufacturingtolerancetopartialshading �"�"'� ��������� � �'������ "����'�� � ��������� ����"���""""' � 60 Flexible system design for maximum space utilization l� Fast installation with a single bolt — Next generation maintenance with module-level monitoring — Module-level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL AUSTRALIA www.solaredge.us N . tcy SolarCity SleekMountTM - Tile with Post The SolarCity SleekMount hardware solu- •Zep Solar hardware and UL 1703 listed Zep tion is optimized to achieve superior Compatible modules strength and aesthetics while minimizing •Interlock and ground devices in system UL listed roof disruption and labor.The elimination of to UL 2703 visible rail ends and mounting clamps, •Interlock and Ground Zep ETL listed to UL 1703 as combined with the addition of array trim all "Grounding and Bonding System" contribute to a more visually appealing • No the cutting required system. SleekMount utilizes Zep Compat- ibleTM modules with strengthened frames •Ground Zep UL and ETL listed to UL 467 as that attach directly to Zep Solar standoffs, grounding device effectively eliminating the need for rail and •Anodized components for corrosion resistance reducing the number of standoffs required. Components R ZS Tile Roof Attachment Kit 4 . ZS Tile Replacement Flashing • Leveling Foot Q Lag Screw 5/16"Wood Lag Screw I Installation Instructions Drill pilot hole • Seal pilot hole • Place roof attachment kit • Install lag t I�O JPERTINO g D� a S Install flashing to jurisdiction preferences { , SwIdin p 'tlV ;�-� k .� � rtment �•, (see standoff detail on plans) -^- }: \.\ Secure leveling foot to roof attachment kit _ AUG 201 \ \ using machine screw Place module REvIEVjEC r:op. �� CtCOM PLtANCE Rcvieweld Do y, 1�' SolarCity o January2014 _ * .............. .....------- -...---- _..._................--- SolarCity Advantage Module Electrical Parameters at Standard Test Conditions (STC) The SolarCity Advantage module represents a 60 Cell,ZEP enabled Power Output Pmax W 255 module.The values shown are the most extreme potential values Power Output Tolerances APmax W -0/+5 from SolarCity's portfolio of CEC approved and UL or ETL listed Module Efficiency nm % 15.85 modules. Modules will have a minimum 10 year warranty.The Maximum Power Voltage Vmp V 30.2 module installed will be one of the following: Maximum Power Current Impp A 8.43 Open-circuit voltage Voc V 37.7 Short-circuit current Isc A 9 Trina Solar:TSM255PA05.18 Canadian Solar: CS6P-255PX Values at Standard Test Conditions STC(Air Mass AM1.5,Irradiance 1000W/m2,Cell Temperature 25°C). Electrical Parameters at Nominal Operating Cell Temperature (NOCT) Power Output Pmax W 185 Voltage at Pmax Vmpp V 27.4 Current at Pmax Impp A 6.77 Open-circuit voltage Voc V 34.4 Short-circuit current Isc A 7.31 NOCT:Irradiance at 800W/m',Ambient Temperature 20°C,Wind Speed 1M/s. Thermal Characteristics Nominal operating cell temperature NOCT °C 46+/-2 Temperature coefficient of Pmax y %/°C -0.43 Temperature coefficient of Voc (3VOC %/°C -0.34 Temperature coefficient of Isc alsc %/°C 0.065 General Characteristics Solar Cells Multicrystaline Frame Aluminum alloy/anodized black Weight 45.2 lbs (20.5 kg) - ' CUPERTINO l Building Department U 132014 ev�ewed By. 'i TSM-PA05.18 TRINAMOUNT II WITH THE UNIVERSAL MODULE Mono Multi Solutions DIMENSIONS OF PV MODULE TSM-PA05.18 ELECTR I CAL DATA Cel STC TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA0518 PA05.18 PA05.18 PA05.18 PA05.18 941mm Peak Power Wotts-PM,,x(Wp) 240 245 250 255 260 Power Output Tolerance-Pm (%) 0/+3 0/+3 0/+3 0/+3 0/+3 Maximum Power Voltoge-VMr(V) 29.7 30.2 30.3 30.5 30.7 I� o Maximum Power Current-Irx°v(A) 8.10 8.13 8.27 8.36 8.47 TSM = PA05 .1 NIMEPUTE Open Circuit Voltage-Voc(V) 37.3 37.5 37.6 37.7 37.9 wmrii a ^+n"r�"xE Short Circuit Current-Isc(A) 8.62 8.68 8.85 8.92 9.00 Module Efficiency nm(%) 14.7 15.0 15.3 15.6 15.9 THE TRINAMOUNT MODULE STC:Irradiance 1000 reduction Cell Temperature /m2 Air Mass to 5 according to EN 609043. Average efficiency reduction of 4.5%0l 200 w/m'according to EN 60904-1. E a E 3 3 ELECTRICAL DATA @ NOCT TSM-240 TSM-245 'TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 60 ���� Maximum Power-P.. 174 178 181 184 188 /rte Maximum Power Voltoge-V„ (v) 26.6 26.8 27.0 27.2 27.4 MULTICRYSTALLINE MODULE <,AOUxDPX KKE A A Maximum PowerCurrent-IMrr(A) 6.S5 6.64 6.70 6.77 6.86 WITH TRINAMOUNT FRAME " Open Circuit Voltage(V)-Voc(V) 34.1 34.2 34.3 34.4 34.6 Short Circuit Current(A)-Isc(A) 7.04 7.10 7.25 7.31 7.37 812mm 180 NOCT:Irradionce at 800 w/m'.Ambient Temperature 20°C.wind Speed I m/s. 240-260W Back View POWER OUTPUT RANGEMECHANICAL DATA Our most versitile product „ Compatible with all major BOS components and system Solar cells Multicrystalline 156 x 156 mm(6 inches) r designs Cell orientation 60 Cells(6 x 10) 1 J Module dimensions 1650 x 992 x 40 mm(64.95 x 39.05 x 1.57 inches) 0 Weight 18.6 kg(41'.0IWI MAXIMUM EFFICIENCY Ll Glass High transparency solar glass 3.2 mm(0.13 inches) Backsheet White One of the industry's most trusted modules Over 2 GW sold across all major global markets Frame Black Anodized Aluminium Alloy with TrinamovntGroove • y Field proven performance I-V CURVES OF PV MODULE TSM-245 PA05.18 J-8ox IP 65 or IP 67 rated O~ ■ 37 - Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), IO.m 1100 mm 143.3 inches) POWER OUTPUT GUARANTEE _. 9.ro i goo, a. Connector Original MCA _7- 800w/rn2 Highly reliable due to stringent quality control <6m°0 m m 5. As a leading global manufacturer Over 30 in-house tests (UV,TC, HF,and many more) u a- TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic - • In-house testing goes well beyong certification requirements 3° 200w{m° Nominal Operating Cell 45°C(±2°C) Operational Temperature -40-+85°C products,v:e believe close 2° Temperature(NOCT) cooperation with our partners o� Maximum System IOOOVDC(IECJ/ is critical to success. With local 0.- 10.00 20.40 Wm 40- Temperature Coefficient of P- -0.43%/°C Voltage 600V DC(UL) presence around the globe,Trina Is --_ voltage(V) Temperature Coefficient of Voc -0.32%/°C Max Series Fuse Rating 15A able to provide exceptional service Temperature Coefficient of Isc 0.047%/°C t0 each customer in each market and supplement our innovative, Certified to withstand challenging environmental WARRANTY I r Y re)ioble products with the backing conditions j � � t`IIYO of Trina as a strong,bankable 130 km/hr wind load (2400 Pa) partner. We are committed 900 kg snow load per module (5400 Pa) 10 year Product Workmanship Warranty aa� kIulld(r1g elPa!tt1?ent to building strategic,mutually beneficial collaboration with 25 year Linear Power Warranty { i installers,developers,distributors A`� 1 2014 (Please refer to product warranty for details) i 1 and other partners as the backbone of our shared success in CERTIFICATION }� ) l'/�(� r o driving Smart Energy Together, LINEAR PERFORMANCE WARRANTY PACKAGING CONFIGURATION LR CODE GOl OWANCE 10 Year Product Warranty • 25 Year Linear Power Warranty 4' \_,l .Qu, Modules per box:24 pieces r�ev:�yved By Trina Solar Limited ,,--,., Modules per 40'container:672 pieces www.trinasolar.com W00% ±. I�E c �L es pjCYCLE o Add,... l w a usrm v value 90% QOM o Satar o S llRear Wa7anty • CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. pPKP4 �` �'`�t' ®2013 Tnno Solor Limited.All rights reserved.Specifications included in this dolosheel ore subject to TrinaSOlar O 80% Trinasoll-.1I chonge without notice. g fes/ Smart Energy Together Smart Energy Together 'OW Years 5 10 16 20 25 1.111!ev ■ Industrystandard 0 Trina Solar f e CS6P-235/240/245/250/255PX es16 �1 Ne Ug�FTsmeV �r CanadianSolar Electrical Data Black-framed STC Cs6P-235P CS6P-240P CS6P-245PCS6P-250P Cr,6p-265px Temperature Characteristics Nominal Maximum Power(PmaxL 235W 240W 245W 25OW 255W _ Optimum OperatingVoltage(Vmp 29.8V 29.9V 30.OV 30.1V 30.2V Pmax .0.43%/C NewEdgOptimum Operating Current(Imp) 7.90A 8.03A 8.17A 8.30A 8.43A Temperature Coefficient Voc -0.34%PC Open Circuit Voltage(Voc) 36.9V 37.OV 37AV 37.2V 37AV Isc 0.065%/'C - - . a Short Circuit Current(Isc) 8.46A 8.59A 8.74A 8.87A 9.00A Normal Operating Cell Temperature 45+2•C Module Efficiency 14.61% 14,92% 15.23% 15.54% 15.85% Operating Temperature .40'C-+85'C Performance at Low Irradiance Maximum System Voltage 1000V IEC /600V UL leading Indust ry g performance at low irradiation Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an Application Classification Class irradiance of 1000w/m'to 200w/m' Power Tolerance 0-+5W (AM 1.5,25 C) Next Generation Solar Module Under Standard Test Conditions(STC)ofirredience of 1000W/m',spectrum AM 1.5 and cell tempameture,025C NewEdge,the next generation module designed for multiple Engineering Drawings NOCT CS6P-235PX CS6P-240P CS6P-245PX CS6P•250PX CS6P-255PX types of mounting systems,offers customers the added Nominal Maximum Power Pmax 170w 174W 178W 181W 185w value of minimal system costs,aesthetic seamless Optimum Operating Voltage(Vmp) 27.2V 27.3V 27AV 27.SV 27.5V appearance,auto groundingand theft resistance. Optimum Operating Current(Imp) 6.27A 6.38A 6.49A 6.60A 6.71A ' Open Circuli Voltage(Voc) 33.9V 34.OV 34.1V 34.2V 34AV The black-framed CS6P-PX is a robust 60 cell solar module short Circuitcurrent(Isc) UliA 6.96A 7.08A 7.19A 7.29A Incorporating the groundbreaking Zap compatible frame. Under Normal Operating Cell Temperature,Irredlence of800W/m',spectrum AM 1.6,ambient temperature 201C, The specially designed frame allows for rail-free fast wind speed 1 m/a installation with the industry's most reliable grounding Mechanical Data system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156 x 156mm,2 or 3 Busbars Key Features silicon cells laminated with a white back sheet and framed Cell Arrangement 60(6 x 10) with black anodized aluminum.The black-framed CS6P-PX Dimensions 1638 x 982 x4Omm(64.5 x 38.7 x 1.57in) • Quick and easy to install - dramatically is the perfect choice for customers who are looking for a high Weight 20.5kg(45.2 lbs) reduces installation time quality aesthetic module with lowest system cost. From Cover 3.2mm Tempered glass Frame Material Anodized aiuminlum alloy • Lower system costs - can cut rooftopJ-Box IP65,3 diodes installation costs In half Best Quality � J • 235 quality control points in module production Cable 4mm'(IEC)/l2AWG(UL),1000mm • Aesthetic seamless appearance - low profile • EL screening to eliminate product defects Connectors MC4 or MC4 Comparable with auto leveling and alignment Current binning to improve system performance Standard Packaging(Modules per Pallet) 24pes Module Pieces per container(40 ft.Container) 672pcs(40'HO) • Accredited Salt mist resistant • Built-In hyper-bonded grounding system - ifit's I-V Curves (CS6P-255PX) mounted,it's grounded Best Warranty Insurance • Theft resistant hardware • 25 years worldwide coverage a I 100%warranty term coverage r. SectionA-A • Ultra-low parts count - 3 parts for the mounting • Providing third party bankruptcy rights 35.0 and grounding system • Non-cancellable -e coverage !�5 �s i � • Industry first comprehensive warranty insurance by • Immediatef ra AM Best rated leading insurance companies in the • Insured by 3 world top insurance companies .�������� worldI~/ uildin Comprehensive Certificates — m� -- ;a� 't 9 Department • Industry leading plus only power tolerance:0­5W IEC 61215,IEC 61730, IEC61701 ED2,UL1703, __ • Backward compatibility with all standard rooftop and CEC Listed,CE and MCS 'llri igd : ground mounting systems • IS09001:2008:Quality Management System Specifications Included In this detasheet are subject to change without prior notice. ISO/TS16949:2009:The automotive quality ' r�EVIE*�� ��IJ - OfY (,:ODE C(J1MFyLiAiV( iF • Backed By Our New 10/25 Linear Power Warranty management system Plus our added 25 year insurance coverage • IS014001:2004:Standards for Environmental About Canadian Solar -�evl w. management system @ tr0 9 Y Canadian Solar Inc. Is one of the world's largest solar Canadian Solar was founded In Canada In 2001 and was 110 • QC080000 HSPM:The Certification for companies. As a leading vertically-Integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) In t% Added Value Frorrl We Hazardous Substances Regulations manufacturer of Ingots,wafers,cells,solar modules and November 2006. Canadian Solar has module manufacturing g0x rant solar systems, Canadian Solar delivers solar power capacity of 2.05GW and cell manufacturing capacity of 1.3GW. • OHSAS 18001:2007 International standards for products of uncompromising quality to worldwide sox occupational health and safety customers. Canadian Solar's world class team of ox professionals works closely with our customers to s 10 15 20 is ' REACH Compliance provide them with solutions for all their solar needs. •10 year product warranty on materials and workmanship 0&S�V C E f �. •25 year linear power output warranty ry Fax -1 519 837 2550 www.canadiansolar.com EN-Rev 10.17 copyright 0 2012 Cmedlen Solar IM. solar=ee Single Phase Inverters for North America solar SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ SE7600A-US/SE1000OA-US/SE11400A-US SE3000A-US I SE3800A-US I SESODOA-US I SE60DOA-US SE760OA-US I SE10000A-US I SE1140OA-US OUTPUT Nominal AC Power Output 3000 3800 sow 6000 7600 9980 @ 208V 11400 VA SolarEdge Single Phase Inverters . � qz�y. ............................. ........................................... ................ ............... ............ • Max.AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA For North America 5450 ?40y. ............... .................10950@240V. .... .... ........... AC Output Voltage Min:Nom:Max.' SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ A.COut 8-229 Vac .................................... AC Output Voltage Min:Nom:Max.' SE760OA-US/SE10000A-US/SE1140OA-US 211-.2a0:264vac..................... ............. ............ ..... .... .... . .. .. ......... .................... ..... ..... ...... ......... AC Frequenry Min..Nom:.Max-'_. ...59.3-60-60.5(with HI country setting 57-60-60.S) _,Hz, Max.Continuous Output Current 12.516 24 @ 208V 25 32 48 @ 208V 47.5 A ..... ....... ... ..... ........ ........ ..21 @.240V. . .. .. . .. . 42 @ 240V .................. ........... GFDI.................................... ............................................................1.................................................. A ...................... Utility Monitoring,Islanding I Protection,Country Configurable Yes "w e r tee. Thresholds CJ INPUT •122 Recommended Max.DC Power" a•, .feats 3750 4750 6250 7500 9500 12400 14250 w Wilt<anly i (5TC).................................... ................ ................................ ................ .................................. ............................. U�• Transformer-less,Ungrounded Yes af,ah ..................................................................................................................................... Max.Input Voltage 500 Vdc ........................................... .......................................................................................................................... ........... I Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc .... .. .. .. ......... 8 Max.Input Current- 9.5 13 15.5 @ 208V 18 23 33 @ 208V 34.5 Adc 15.5 @ 240V 30.5 @ 240V Max.Input Short Circuit Current 30 45 Adc Max ................................................................. Reverse-Polarity Protection Yes ........................................... ............................................................... ........................................................... .........- Ground-Fault Isolation Detection 600ko Sensitivity ..................................on..... ................ ............... ................................. .................................. .................. ........... MaximuminverterEfficiency .,, 97;7. ._..98.2___._.___.._98.3,._... ._.._98:3 98 98 98 % .................. ..... . ..... ............................ ... CEC Weighted Efficiency 97.5 98 97.5 @ 208V 97 5 97.5 97 @ 208V 97.5 % 98 @ 240V 97.5 @ 240V ....g..........ver ........P............ ................ ............... ................. ................ .................................. ............................. Ni httime Power Consum tion <2.5 <4 W ' ADDITIONAL FEATURES { -- Supported Communication Interfaces R5485,R5232,Ethernet,ZgBee(optional) i.. ........................................... .......................................................................................................................... ........... Revenue Grade Data,ANSI C32.1 Optional t STANDARD COMPLIANCE -- _-�- Saf..e ...L7UL.........U1699B, L3998,CSA 22.2 + -� .... ................................... U141,........................................ ......... ........................................................................ b Grid Connection Standards IEEE1547 ........................................... ..................................................................................................................................... Emissions FCC pa 1'5 class B INSTALLATION SPECIFICATIONS AC output conduit size/AWG range 3/4"minimum/24-6 AWG 3/4"minimum/8-3 AWG .................................. ........................................... ............................................... DC input conduit size/k of strings/ 3/4"minimum/1-2 strings/24-6 AWG 3/4"minimum/1-2 strings/14-6 AWG AWG range ........................................... .................................................................. ...................................................... ........... Dimensions with AC/DC Safety 30.5: 12.5 x 7/ 30.5 x 12.5 x 7.5/ in/ 30.5 x 12.5 x}0��(,Z75 x 315 x 260 Switch(HxWxD)...................... ......775x315x172..,,,. 775x315x191,.._... __.............., ..: . mrEtY,,. Wei ht with AC DC Safe Switch 51.2 23.2 S4.7 24.7 _ .. , g. .. ..../ �. ....... 88.4/ Q.1 bks RT Cooling Natural Convection Fans(user rep acea6iie) .. _ _ _ Noise .. .... . .... ....... ..<25.. ... ..... .... ', �<,59... ... ........dr)ding Department The best choice for SolarEd a enabled systems g Y Min.-Max.Operating Temperature -13 to+140/.25 to+60(CAN version*--40 to+60) Integrated arc fault protection(Type 1)for NEC 2011690.11 compliance ..Ra p? I. - Protection Rating NEMA 3R '` ..4 Superior efficiency(98%) .... ....... ........ ......... ......... ......... ......... ......... ......... .... ..... ... . ..... •For other regional settings Dle:se contact SolarEdge support - Small,lightweight and easy to install on provided bracket Umitedto125%forlocattm ,I,erethe yeartyaveragehigh remperar„reuabo.errF/25-cand ro135%fmlomuon,.memIthbekmT7F/u•c For detailed information,refer to httn:i/www.solaredn.usisle ID&An ner do o�,ersi:lne evide.odf •i` 1 �'+ �J f l..l I"'! v U(] COMPLIANCE M F I - Built-in module-level monitoring ;, Ahlghernrrem�ooroamaybea:ee;fheln�enarwmumiflf,Inpafarren:fo ne�al�aF:aoae. LIANCE '•CAN P/Ns are eligible for the Ontario Fn and micmFn(mkmFIT mz 5111400"S-CAN).Internet connection through Ethernet or Wireless F<cv�ewt?d �v. - Outdoor and indoor installation - Fixed voltage inverter,DC/AC conversion only - Pre-assembled AC/DC Safety Switch for faster installation - Optional-revenue grade data,ANSI C32.1 sunsvcC USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us Z®Solar TRIANGLE ARRAY TRIM I INFORMATION SHEET Ze®Solar TRIANGLE ARRAY TRIM I INFORMATION SHEET Triangle Array Trim Mechanical Installation Information Sheet 1i The Triangle Array Trim is a non-functional PV component with Left and Right versions that is specifically — — designed for appearance.It is intended for use in Landscape arrays of Zep Compatible'modules,with a stagger design where the rows of PV modules are offset exactly at the halfway point Triangle Array — Trims may be installed without any modification of spans or cantilevers,given the following design considerations: , • For ASCE 7-05,Exposure B or C with wind speeds not to exceed 100 mph,or 2 • For ASCE 7-10,Exposure B or C with wind speeds not to exceed 130 mph Each Triangle Array Trim component has four points of structural connection with adjacent • Ground snow load not to exceed 20 psf modules.These are special hardware fasteners called"Zeps". Q�,o=P4t4, Each'Zep"is permanently riveted to the Triangle Array Trim metal frame.Use the Flat Tool to V. / rotate the Zep in place 90 degrees. Azb14pl►'�0 [10.3751 263.52 Cut-out gap fits the end of the Flat Tool. [49.8451 3 1266.05 T-$ B [38,6231 117.501 981.02 Flat Tool PV 1 Triangle module Array Trim Cross Section [10.7281 272.5 �g6�OCk Alignment notch used as a Right-angled hook fits visual aid to indicate full 90 I I the matching gap on degree rotation. (5.6861 the"Zep". 151S061 [2512631 144.43 1806.73 1 I SUlldlnQ C 1 AVG 13 2�t4 Document 800-1574-001 Revc www.2epsoiar 0tn PAGE: 1 Oft Document80D-1574-001Rev C wwwmpwtareom E 1EVVED iPJWI'S 2W)OE ®2014/EN Zep Solar,Inc.Zep Solar reserves the right to make specifications Changes without any prior notice.All rights reserved. 0 2014/EN Zep Solar,Inc.Zep Solar reserves the right to make Specifications changes without any prior notice.All rights reserved. �t Date Last Exported:May 13.20141:39 PM Date Last Exported:May 13,20141:39 PM ;�evlevred 8