Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
14070107
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 22064 BAXLEY CT CONTRACTOR: SOLARCITY PERMIT NO: 14070107 OWNER'S NAME: DU JUN AND CHEN PING TRUSTEE 3055 CLEARVIEW WAY DATE ISSUED: 07/23/2014 OWNER'S PHONE: 6505750732 SAN MATEO, CA 94402 PHONE NO: (650) 638-1028 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL E] COMMERCIAL INSTALL 20 ROOF TOP, FLUSH MOUNTED PV PANELS (5.1 License Class L� �� Lemic. # Q Q C o KW) ` l Date C34 �3 Contractor I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the erformance of the work for which this permit is issued. Sq. Ft Floor Area: Valuation: $12000 I have and will maintain Worker's Compensation Insurance, as provided for by APN Number: 35606028.00 Occupancy Type: Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter 180 DAYS SPECTION. upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the 2 3 granting of this permit. Additionally, the applicant understands and will comply with all non- 'nt source regulations per the Cupertino Municipal Code, Section RE -ROOFS - 9.18. Signature Date �� I All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by for the work for which this the Health & Safety Code, Section 25 5, 533, and 25534. 1Lr Section 3700 of the Labor Code, the performance of Owner or authorized agent: DateJ41 permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address -- I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date CUPERTINO ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION O 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(c)cupertino.org l �� AE PROJECT ADDRESS- G� APN # � — — DZ i 0 OWNER NAME ��'-� \l► ISG fV PHONE c0 50 .?5 a 3Z E-MAIL STREET ADDRESS 220 k C -c, CITY, STA ZI _ u 1 o C— Ct FAX CONTACT NAMF�� nen ^ y _ L PHONE I d L „ (��C E-MAIL n , P. (�� STREET ADDRESS ^��Sl-�` b' -(I �J CI , STATE, ZIP FAX ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME —12� :" 1�1v LICENSE NUMBER !Q `9 Iq 1 0 4C LICENSE TYPE G C2 BUS. LIC # ` p COMPANYNAME,SOLA A ^ ('niV j� " ` EMAIL i�A A w QG W l S'ja FAX STREET ADDRESS .ATE, ZIP Ij PHONE ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF LTJfFD or Duplex ❑ Multi -Family STRUCTURE: ❑ Commercial PROJECT IN WILDLAND URBAN INTERFACE AREA ❑ Yes ❑ No PROJECT IN FLOOD ZONE ❑ Yes ❑ NO Y� SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNTTS: KILOWATTS (COMMERCIAL ONLY): , _ \ �(TV TOTAL VALUATION: DESCRIPTION OF WORK e2_0 C p FbA w , ``u By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the propel d this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. e to comply with all applica ordinances and state laws relating t ui g nstruction. I authorize representatives of Cupertino to enter the above -identified property for inspection purposes. Signature of Applicant/Agent: Date: O 2 1 SUPPL ENTAL INFORMATION REQUIRED OFFICE USE ONLY w ❑ OVER-THE-COUNTER E' Y= ❑ EXPRESS U w ❑ STANDARD U" LARGE ❑ MAJOR PVApp_2011.doc revised 03116/11 La CITY OF CUPERTINO FEE ESTIMATOR - BUILDING DIVISION 19 ADDRESS: 22064 BAXLEY CT F-1 1- DATE: 07/23/2014 REVIEWED BY: MELISSA APN: 356 06 028 BP#: 140 % / -VALUATION: $12,000 µPERMIT TYPE: Building Permit 1 # $236.00 PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex USE: p FO.0 1 PENTAMATION SOLAR -RES PERMIT TYPE: i WORK I INSTALL 20 ROOF TOP FLUSH MOUNTED PV PANELS 5.1 k SCOPE NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public works, Fire, sanitary Sewer District, Scnoot D'r s t 'ct etG These ees are based on the relimina information available and are on1v an estimate. Contact the De t or addn'l in o. FEE ITEMS (Fee Resolution 11-053 E . 711113) F-1 1- Tlrtr�tr`�. iasr3. 1 et Ll _L_ NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public works, Fire, sanitary Sewer District, Scnoot D'r s t 'ct etG These ees are based on the relimina information available and are on1v an estimate. Contact the De t or addn'l in o. FEE ITEMS (Fee Resolution 11-053 E . 711113) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 1 # $236.00 Alternative Energy System 1PHOTOVREs Photovoltaic System Suppl. PC Fee: (j) Reg. OT FO.0 1 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:Q Reg. Q OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 __F_T {'0!2W7L1C!i0i1 'LLV. r1dTPZtn4strcllit 1't E> O 0 Work Without Permit? 0 Yes Q No $0.00 Advanced Planning Fee: $0.00 Select a Non -Residential Building or Structure 0 Q j7 ?'rol'£'i PICT!"r,LJl:Dt,'t7ldtilrlY/ %'t't'. Strong Motion Fee: IBSEISMICR $1.56 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: $2.56 $236.00 TOTAL FEE: $238.56 Revised: 07/10/2014 ABBREVIATIONS ELECTRICAL NOTES I JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG BUILDING CONIC CONCRETE DC DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Imp CURRENT AT MAX POWER Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL PROPERTY LINE POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC SCH SCHEDULE SS STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT LTCENSE CA # 888104 C-10 MODULE GROUNDING METHOD: ZEP SOLAR I AHJ: Cupertino UTILITY: Pacific Gas and Electric Company 1. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 2. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 3. A NATIONALLY -RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(8) 5. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 7. MODULE FRAMES SHALL BE GROUNDED AT THE UL -LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS AND GROUNDED AT THE MAIN ELECTRIC PANEL. 9. THE DC GROUNDING ELECTRODE CONDUCTOR SHALL BE SIZED ACCORDING TO ART. 250.166(8) & 690.47. FLASHING WILL BE PAINTED TO MATCH EXTERIOR VICINITY MAP GENERAL NOTES 1. THIS SYSTEM IS GRID-INTERTIED VIA A UL -LISTED POWER -CONDITIONING INVERTER. - 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED. 4. ALL WORK TO BE DONE TO THE 2013 CALIFORNIA BUILDING CODE AND THE 2013 CALIFORNIA RESIDENTIAL CODE. 5. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. CONFIDENTIAL — THE INFORMATION HEREIN ADB NUMBER: JB -9503116 0 0 CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE MODULES: (20) Advantage Module SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION of SOLARCITY INC. SOLAREDGE SE5000A-US-ZB-U PREMISE OWNER: CHEN, PING 22064 BAXLEY CT CUPERTINO, CA 95014 (650) 575-0732 CHEN RESIDENCE 5.1 KW PV ARRAY PAGE NAME: COVER SHEET <�FOCE Tt, � CEIVE.D JUL 2 3 2014 ,K7 BY 1 g CUPFRTM---iiLDG. DEPT. ;� M Building Department .,. AYS" 1... 2,) 2iGJ REVIEWED FOR CODE COMPLIANCE Reviewed By. j'--11 11�41'w INDEX PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS PV5 THREE LINE DIAGRAM Cutsheets Attached REV BY DATE COMMENTS REV A NAME DATE COMMENTS George Kostov �WksolarCit` , . 6'o� G ,3fv✓ 3055 Clearview Way SHEET: REV: DATE: Sonateo, CA 94402 T:(650) 638-1028 F.(650) 638-1029 PV 1 6/10/2014 (888)—SOL—CITY (765-2489) www.solarcity.com 22064 Baxley Ct PITCH: 25 ARRAY PITCH: 25 MP1 AZIMUTH: 90 ARRAY AZIMUTH: 90 MATERIAL: Flat Cement Tile STORY: 2 Stories PITCH: 12 ARRAY PITCH: 12 MP2 AZIMUTH: 270 ARRAY AZIMUTH: 270 MATERIAL: Flat Cement Tile STORY: 1 Story 1 Fr,Fnrrn O (E) UTILITY METER & WARNING LABEL Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS FDC IESI DC DISCONNECT & WARNING LABELS ° ° 4LLu CUPF_RT � AC DISCONNECT & WARNING LABELS I ► ;s Building Depa I A B DC JUNCTION/COMBINER BOX & LABELS �--___— — — 0° DISTRIBUTION PANEL &LABELS " REVIEWED FOR CODE COMPL PLUCIE Reviewed 8y. �.•� LG LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR — GATE/FENCE Q HEAT PRODUCING VENTS ARE RED 1, INTERIOR EQUIPMENT IS DASHED L =/J TOTAL ARRAY AREA (SF): 360 SITE PLAN N TOTAL ROOF AREA (SF): 1820 Scale:1/16" = 1' W E TOTAL ARRAY AREA IS p 19.76 01 16' 32' PERCENT OF TOTAL ROOF AREA s J B— 9503116 O O PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL —THE INFORMATION HEREIN JOB NUMBER: �� CONTAINED SHALL NOT BE USED FOR THE CHEN, PING CHEN RESIDENCE George Kostov �;,;So�arCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 'W,,1 NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 22064 BAXLEY CT 5.1 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES. CUPERTINO, CA 95014 &'cis G - �/ ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearvier Way THE SALE AND USE OF THE RESPECTIVE (20) Advantage ModuleSI1EET: REV: DATE: San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PACE NAME T:(650) 638-1028 F:(650) 638-1029 PERMISSION OF SOLARCITY INC. INVERTER. SOLAREDGE #SE5000A-US-ZB-U (650) 575-0732 SITE PLAN PV 2 6/10/2014 (8N) -SOL -CITY (765-2489) MIW.SOIafCIty.Caff CA ' SIDI VIEW 01 MP1 NTS MP1 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" 48" 24" By: PORTRAIT 1 48" 20" 48" 24" RAFTER C.J. 2X10 @ 24" OC None @24" OC ROOF AZI ARRAY AZI 90 PITCH 25 STORIES: 2 90 PITCH 25 Flat Cement Tile ZEP SPANNER BAR " DIA BOLT & NUT (1) ZEP SPANNER BAR CLAMP STANDOFF (E) TILE (E) ROOF DECKING 5/16" DIA LAG BOLT (2-1/2" EMBED, MIN) LOWEST MODULE (E) RAFTER SUBSEQUENT MODULES STANDOFF S 1 Scale: 1 1/2" = 1' INSTALLATION ORDER LOCATE RAFTER, MARK RAFTER LOCATION, AND REMOVE TILE. (1) PLACE STANDOFF BASE & DRILL PILOT HOLES AT THE RAFTER LOCATION. 2) CLEAN PAPER AROUND PILOT HOLE. 3) ADJUST STANDOFF TO BATTEN HEIGHT. SEAL PILOT HOLES AND BOTTOM (4) OF STANDOFF WITH POLYURETHANE SEALANT. 5) LAG STANDOFF INTO RAFTER. (6) NOTCH TILE WEATHERING TO FIT AROUND STANDOFF. 7) REINSTALL TILE. 1 4b Building Department e CONTAINED REVIEWED FOR CODE COMPLIANCE By: h7-001 SUBSEQUENT MODULES STANDOFF S 1 Scale: 1 1/2" = 1' INSTALLATION ORDER LOCATE RAFTER, MARK RAFTER LOCATION, AND REMOVE TILE. (1) PLACE STANDOFF BASE & DRILL PILOT HOLES AT THE RAFTER LOCATION. 2) CLEAN PAPER AROUND PILOT HOLE. 3) ADJUST STANDOFF TO BATTEN HEIGHT. SEAL PILOT HOLES AND BOTTOM (4) OF STANDOFF WITH POLYURETHANE SEALANT. 5) LAG STANDOFF INTO RAFTER. (6) NOTCH TILE WEATHERING TO FIT AROUND STANDOFF. 7) REINSTALL TILE. CONFIDENTIAL —THE INFORMATION HEREIN SHALL NOT BE USED FOR THE CUPERTINO 4b Building Department e CONTAINED REVIEWED FOR CODE COMPLIANCE By: h7-001 CONFIDENTIAL —THE INFORMATION HEREIN SHALL NOT BE USED FOR THE JOB NUMBER: J B- 9503116 0 0 PREMISE OWNER: DESCRIPTION: CHEN, PING CHEN RESIDENCE DESIGN: George Kostov 4$ CONTAINED A'k' ;;So�arCity MOUNTING SYSTEM: BENEFIT OF ANYONE EXCEPT SOLARCITY INC., 22064 BAXLEY CT 5.1 KW PV ARRAY NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ZEP Mighty Hook CUPERTINO, CA 95014 '! 6-eT G /=y,r�,,�/ ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE MODULES (20) Advantage Module PAGE NAME -�` 4' 3055 San Matteoeo,, CCA Way A 94402 SHEET: REV: DATE: SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. (650) 575-0732 STRUCTURAL VIEWS PV 3 6/10/2014 T:(650) 638-1028 F:(650) 638-1029 (888) -SOL -CITY (765-2489) www.solarcity.com INVERTER: SOLAREDGE �#SE5000A—US—ZB—U CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: JB -9503116 MOUNTING SYSTEM: ZEP Mighty Hook MODULES: (20) Advantage Module INVERTER: SOLAREDGE #SE5000A-US-ZB-U 00 PREMISE OWNER: CHEN, PING 22064 BAXLEY CT CUPERTINO, CA 95014 (650) 575-0732 UPLIFT CALCULATIONS 06.10.2014 SolarCity SleekMountT"' PV System Version #37.0 Structural Desian Software Project Information & Table Of Contents Risk Category: II PV System Type SolarClty SleekMount'" Flat Tile Roof Flat Tile Roof Layers of Comp Roofing Roof Slope 251 Rafter S adn 24" O.C. PV System Module Orientation Landscape and Portrait PV Module Area 352 sf PV Module Width 39" PV Module Length 65" Standoff Attachment Hardware Mighty Hook HDG FT Reduced Ground/Roof Live/Snow Loads Ground Snow Load pg 0.0 psf ASCE Table 7 1 Surrounding Roof Snow 0.0 psf ASCE Eq: 7.4-1 Roof Snow Over PV Modules 0.0 psf ASCE Eq: 7.4-1 Wind Design Criteria Wind Design Code ASCE 7-10 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 110 mph Fig. 26.5-1A Exposure Category C Section 26.7 Roof Style Gable Roof Rg. 30.4-2A/8/C-5A/B Mean Roof Height h 25 ft Section 26.2 Effective Wind Area 1 Module A 17.6 sf IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.95 Table 30.3-1 Topographic Factor Kzt 1.00 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) 24.9 pst Equation 30.3-1 Ext. Pressure Coefficient (Up) GCp (Up) -0.88 Fig. 30.4-2A/ B/C-5A/B Ext. Pressure Coefficient Down GC Down 0.45 Fig. 30.4-2A/B/C-5A/B Design Wind Pressure P p = gh GC Equation 30.4-1 Wind Pressure Up P(up) -21.8 psf Wind Pressure Down down 16.0 psf Allowable Standoff Spacings ' X -Direction Y -Directs Max Allowable Standoff Spacing Landscape 72" 48" " Max Allowable Cantilever Standoff Confi uration Landscape Landscape 24" Not -Staggered 24" Max Standoff Tributary Area Trib 24 sf PV Assembly Dead Load W -PV 3 psf Net Wind Uplift at Standoff T-actual -275lbs REVIDNE1 FOR CC, Uplift Capacity of Standoff T -allow 500 lbs Standoff Demand/Capacity DCR 54.9% - Max Allowable Standoff Spacing Portrait 48" 8" Max Allowable Cantilever Portrait 20" 24" Standoff Configuration Portrait Not -Staggered Max Standoff Tributary Area Trib 16 sf PV Assembly Dead Load W -PV 3 psf Net Wind Uplift at Standoff T -actual -183 lbs Uplift Capacity of Standoff T -allow 500 lbs Standoff Demand/Capacity DCR 36.6% DESCRIPTION: CHEN RESIDENCE 5.1 KW PV ARRAY PACE NAME: UPLIFT CALCULATIONS George Kostov 6-,e_,,17 Z_ ��wl SHEET: REV: DATE: PV 4 6/10/2014 :IERTINO Tg Devartmen-, OrAPLIANCE loi-JIN SolarCity 3055 Clearview way Son Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number: Square D Meter Number: Inv 1: DC Ungrounded INV I — (1) SOLAREDGE ##SE5000A—US—ZB—U LABEL: A — (20) Advantage Module Module; 255W, Poly, 60cell, Blck Frame, White ZEP CA # 888104 C-10 AT PANEL WITH IRREVERSIBLE CRIMP 1008936495 Inverter; 50 OW, 240V, 97.5%; w/Unifed Disco and ZB, AFCI PV Bcksht, INV 2 Overhead Service Entrance Voc: 37.7 Vpmax: 30.2 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER Inverter 1 20OA/2P 3 SOLAREDGE LOADS SE5000A—US—ZB—U (E) 240V SolorCity L1 L2 3OA/2P q — — — — — — — — — — — — — — — — — — — — — — — — — ——— ————— ———————— — — — — —— N _ EG21 --- DC+ GEC DC_ A 2 1 DC+rl DC— 1 String(s) Of 20 On MP 1— /I\ g GND EGC EGC I I ---------------------------- — --I---- -- — — — — I N I I EGC/GEC — z z c� GEC TO 120/240V SINGLE PHASE UTILITY SERVICE 1 I CUPERTINO Building Det,artmenv ,JL 2 3 2014 REVIEV,JED FOR CODE CMPLIANCE Reviewed By. Voc* = MAX VOC AT MIN TEMP POI (1 )SQUARE D g�t HOMT1515730 PV ACKFEED BREAKER p A (1 )SolorCity 4 STRING JUNCTION BOX D� 2x2 STRGS, UNFUSED, GROUNDED Breaker; 15A/1P-30A 2P-15A%1 P, 2 Spaces, Quad Tandem — (1)Ground Rad; 5/8' x 8, Copper% H — (1 ZEP 850-1196-002 Universal Box Bracket; [PKG BJ PV (20)SOLAREDGE1300-2NA4AZS PowerBox timizer, 30OW, H4, DC to DC, ZEP O 1 AWG #10, THWN-2, Block (1 )AWG #10, THWN-2, Red (1 AWG 110, THWN-2, Block O (1)AWG /10, THWN-2, Red Voc* = 500 VDC Isc = 15 ADC Vmp = 350 VDC Imp= 14.38 ADC (2)AWG #10, PV WIRE, Black Voc* = 500 VDC Isc = 15 ADC O (1)AWG J10, Solid Bare Copper EGC Vmp = 350 VDC Imp= 14.38 ADC (1 ) AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp = 20.83AAC (1) AWG #10, THWN-2, . Green EGC .... (1) Conduit. Kit; _ 3/4' ,EMT........ . ................................................................ ....... 70 AWG 18,. THWN-Y,_ Green .. EGC/GEC.- (1) Conduit. Kit;. 3/4' . EMT CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., JOB NUMBER: J B- 9503116 O O PREMISE OWNER: CHEN, PING DESCRIPTION: CHEN RESIDENCE DESIGN: George Kostov ■ •�" �:,;So�arCity. MOUNTING SYSTEM: �� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART OTHERS OUTSIDE THE RECIPIENTS ZEP Mighty Hook 22064 BAXLEY CT 5.1 KIN PV CUPERTIN0 CA 95014 ARRAY MODULES (20) Advantage Module 3055 Clearview Way Son Mateo, CA 94402 IZ ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE � PAGE NAME G✓ SHEET: REV: DATE: SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARGTY INC. INVERTER: SOLAREDGE SE5000A-US-ZB-U (650) 575-0732 THREE LINE DIAGRAM PV 5 6/10/2014 T:(650) 638-1028 F:(650) 638-1029 1 (888)—SOL—CITY (765-2489) www.solorcity.com Label Location: (C)(IC)(CB) Per Code: CRC R331.2 Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: (DC) (INV) Per Code: CEC 690.53 Label Location: (DC) (CB) Per Code: CEC 690.17 Label Location.- (INV) ocation:(INV) Per Code: CEC 690.5(C) Label Location: (AC) (POI) Per Code: CEC 690.14.C.2 Label Location: (AC) (POI) Per Code: CEC 690.54 Label Location: (AC) Label Location: (DC) Per Code: CEC 690.17 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (POI) Per Code: CEC 690.54; CEC 690.17 Label Location: (D) (POI) Per Code: CEC 690.64.B.4 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (DC)(INV)(CB) Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED CUPERTINO Building Department " r .;'UL 2 2G!4 REVIEWED FOR CODE COMPLIANC: Reviewed By. J,, h471W (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �- San Mateo, CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, SC - CA Label Set ����-SOLC)638-1028 89)w) .sola029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE // So1arC�ty (888) -CITY (765-2489)wwwsolarcity.co SOLARCITY EQUIPMENT, 'WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. SolarCity SleekMountTM - Tile The SolarCity SleekMount hardware solution is optimized to achieve superior strength and aesthetics while minimizing roof disruption and labor. The elimination of visible rail ends and mounting clamps, combined with the addition of array trim and a lower profile all contribute to a more visually appealing system. SleekMount utilizes Zep Compatible TM modules with strengthened frames that attach directly to Zep Solar standoffs, effectively reducing the number of standoffs required, when compared to conventional rail -based systems. L E' • Utilizes Zep Solar hardware and UL 1703 listed Zep Compatible TM modules • Interlock and grounding devices in system UL listed to UL 2703 • Interlock and Ground Zep ETL listed to UL 1703 as "Grounding and Bonding System" • Ground Zep UL and ETL listed to UL 467 as grounding device • Anodized components for corrosion resistance • Applicable for vent spanning functions Components Cam Foot ® Spanner Bar ® 3/8" Machine Screw and Nut ® Spanner Bar Clamp ® Tile Hook ® Lag Screw (2) SolarCity SleekMountTM - Tile g/r/ l�'V.,SolarCitW Eta LISTED�-, SolarCityy. January2013 �oMPot® January 2013 Installation Instructions • Remove tile and locate rafter ® Drill pilot holes of proper diameter for fastener size per NDS section 1.1.3.2 ® Seal pilot holes with roofing sealant ® Place tile hook Install lags pursuant to NDS section 11.1.3 with fender washer ® Notch underside of tile and reinstall tile Attach Spanner Clamps and tighten firmly in place • Insert Cam Foot into Spanner Bar and rotate Cam Nut 100 degrees • Place modules 1 CUPERTINO Building Department s L 2614 REVIEWED FOR CODE COMPLIANCE Reviewed By. j,5411 solar- • • SolarEdge Power Optimizer Module Add -On For North America P300 / P350 / P400 PV power optimization at the module -level — Up to 25% more energy — Superior efficiency (99.5%) — Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module -level monitoring — Module -level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us solar4_ SolarEdge Power Optimizer � � Module Add -On for North America P300 / P350 / P400 P300 IP350 P400 �- (for 60 -cell PV (for 72 -cell PV (for96tell PV modules) modules) modules) _ INPUT 1000 Rated Input DC Powerm 300350 Dimensions (W x L x H) Absolute Maximum Input Voltage (Voc at lowest temperature) 4860 T 80 VdcMPPT Operating Range 8-48 8-60 8-80 Vdc Maximum Short Circuit Current (Itsc) 10 MC4/Amphenol/Tyco 'dc Maximum DC Input Current 12.5 Output Wire Type / Connector Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvokage Category II p r� Building DJ oarlllrnent OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) - -40-+85/-40-+185. Maximum Output Curren 15 Adc Maximum Output Voltage 60 IP65 / NEMA4 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer EMC Safety ROHS _ INSTALLATION SPECIFICATIONS FCC Part15 Class 8, IEC61000-6-2, IEC61000-6-3 IEC62309-1 (class II safety), UL1741 Yes Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 141 x.212 x 40.5/ 5.55 x 8.34x 1.59 mm/in. Weight (including cables) 950 / 2.1 gr / It, Input Connector MC4/Amphenol/Tyco CVP:\�it Output Wire Type / Connector Double Insulated; Amphen iV Output Wire Length 0.95/3.0 I 1.2 / 3 m / ft •C/•p p r� Building DJ oarlllrnent Operating Temperature Range -40-+85/-40-+185. , Protection Rating IP65 / NEMA4 , Relative Humidity 0-100 , R^ % tji"1 �nwidsrz oa.e.aen. mm„r. we+. o'w�o •sx,ea.aM. »m,Ma.1 J�� C_w tl`8 PV SYSTEM DESIGN USING A SOLAREDGE INVERTER Minimum String Length (Power Optimizers) Maximum String Length (Power Optimizers) Maximum Power per String Parallel Strings of Different Lengths or Orientations SINGLE PHASE THREEEPHASE RIEW V ED FOR GORE COMPLIANCE 208 480V 10 18 825 saRevl vred By. 5250 60M 12750 W Yes SolarCity Advantage Module The SolarCity Advantage module represents a 60 Cell, ZEP enabled module. The values shown are the most extreme potential values from SolarCity's portfolio of CEC approved and UL or ETL listed modules. Modules will have a minimum 10 year warranty. The module installed will be one of the following: Trina Solar: TSM255PA05.18 Canadian Solar: CS6P-255PX Electrical Parameters at Standard Test Conditions (STC) Power Output Power Output Pmax W 255 Power Output Tolerances APmax W -0/+5 Module Efficiency qrn % 15.85 Maximum Power Voltage Vmp V 30.2 Maximum Power Current Impp A 8.43 Open -circuit voltage Voc V 37.7 Short-circuit current Isc A 9 Values at Standard Test Conditions STC (Air Mass AM1.5, Irradiance 1000W/m', Cell Temperature 25°C). Electrical Parameters at Nominal Operating Cell Temperature (NOCT) Power Output Pmax W 185 Voltage at Pmax Vmpp V 27.4 Current at Pmax Impp A 6.77 Open -circuit voltage Voc V 34.4 Short-circuit current Isc A 7.31 NOCT: Irradiance at 800W/m2, Ambient Temperature 20°C, Wind Speed 1M/s. Thermal Characteristics Nominal operating cell temperature NOCT °C 46+/-2 Temperature coefficient of Pmax y %/°C -0.43 Temperature coefficient of Voc QVoC %/°C -0.34 Temperature coefficient of Isc alsc %/° , �_. 0.065 PFRTING Building Department General Characteristics Solar Cells Multicrystaline Frame Aluminum allay/'46odl�.O WE* L ,L3 ,00MpL;AINCE Weight 45.2 lbs (20.5 kg) „t ✓-�� ' /�v -PA05.18 THE TRINAMOUNT MODULE 60 CELL MULTICRYSTALLINE MODULE WITH TRINAMOUNT FRAME 240-26OW POWER OUTPUT RANGE 15.9% MAXIMUM EFFICIENCY 0--+3% POWER OUTPUT GUARANTEE As a leading global manufacturer of next generation photovoltaic products, we believe close cooperation with our partners is critical to success. With local presence around the globe, Trina is able to provide exceptional service to each customer in each market and supplement our innovative, reliable products with the backing of Trina as a strong, bankable partner. We are committed to building strategic, mutually beneficial collaboration with installers, developers, distributors and other partners as the backbone of our shared success in driving Smart Energy Together. Trina Solar limited www.trinosolar.com Trinasolar Smart Energy Together Our most versitile product {I Compatible with all major BOS components and system designs One of the industry's most trusted modules V • Over 2 GW sold across all major global markets • Field proven performance Highly reliable due to stringent quality control O • Over 30 in-house tests (UV, TC, HF, and many more) • In-house testing goes well beyong certification requirements Certified to withstand challenging environmental ®conditions • 130 km/hr wind load (2400 Pa) • 900 kg snow load per module (5400 Pa) LINEAR PERFORMANCE WARRANTY 10 Year Product Warranty • 25 Year Linear Power Warranty ;,100% d Addition°/ Value e from Trinq S 0 90% °fOr'slinerWc1rran o tY 0 80% Years 5 10 15 20 25 In:!.:.rry vand.vd E Trina Solar TSM-PA05.18 TRINAMOUNT II WITH THE UNIVERSAL MODULE DIMENSIONS OF PV MODULE TSM-PA05.18 E O 941mm ,uN•nJN c BJ% AMEttATE u,nAuwG Hole � 5-043G0.J!NGING HJIF A A iz-ox.iN,wEE R1Jmm 180 Back View I-V CURVES OF PV MODULE TSM -245 PA05.18 Q t U em 7m 6.- 5.. a.m 3.m 2m tm na 9 3 3 0.00 10.- 20.00 30.m 40P Voltage(V) ELECTRICAL DATA @ STC TSM -240 TSM -245 TSM -250 TSM -255 TSM -260 Maximum Power-PMA%(Wp) PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 Peak Power Watts -PMA% (Wp) 240 245 250 255 260 Power Output Tolerance -P- (%) 0/+3 0/+3 0/+3 0/+3 0/+3 Maximum Power Voltage-VMP (V) 29.7 30.2 30.3 30.5 30.7 Maximum Power Current-IMw (A) 8.10 8.13 8.27 8.36 8.47 Open Circuit Voltage-Voc (V) 37.3 37.5 37.6 37.7 37.9 Short Circuit Current-Isc (A) 8.62 8.68 8.85 8.92 9.00 Module Efficiency rlm (%) 14.7 15.0 15.3 15.6 15.9 STC: Irradionce 1000 W/m2, Cell Temperature 250C. Air Mass AMI.S according to EN 60904-3. Average efficiency reduction of 4.5% at 200 W/m2 according to EN 60904-I. Modules per box: 24 pieces TEMPERATURE RATINGS Nominal Operating Cell Temperature (NOCT) Temperature Coefficient of P - Temperature Coefficient of Voc Temperature Coefficient of Isc MAXIMUM RATINGS 45•C (t2•C) Operational Temperature -40-+85°C Maximum System 1000V DC(IEC)/ - 0.43%/°C _ _ voltage /'� 66000pV�DC(UL) -0.32%/°C` (max Series Fuse RCLI�j TING 0.04z] callffnem i TSM -240 TSM -245 TSM -250 TSM -255 TSM -260 ELECTRICAL DATA @ NOCT PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 Maximum Power-PMA%(Wp) 174 178 181 184 188 Maximum Power Voltage -V- (V) 26.6 26.8 27.0 27.2 27.4 Maximum Power Current-IMw (A) 6.55 6.64 6.70 6.77 6.86 Open Circuit Voltage (V)-Voc (V) 34.1 34.2 34.3 34.4 34.6 Short Circuit Current (A)-Isc (A) 7.04 7.10 7.25 7.31 7.37 NOCT: Irradiance at 800 W/m2. Ambient Temperature 200C. Wind Speed 1 m/s. MECHANICAL DATA EVIE'IN D FOR CODE COMPI_t Solar cells Multicrystalline 156 x 156 mm (6 inches) Cell orientation 60 cells (6 x 10) Module dimensions 1650 x 992 x 40 mm (64.95 x 39.05 x 1.57 inches) Weight 18.6 kg (41.0 lbs) Glass High transparency solar glass 32 mm (0.13 inches) ewed By. ,��•..r Backsheet White CERTIFICATION Frame Black Anodized Aluminium Alloy with Trinamount Groove J -Box IF 65 or IP 67 rated Cables Photovoltaic Technology cable 4.0 mm2 (0.006 inches'), SA„ 1100 mm (43.3 inches) Connector Original MC4 TEMPERATURE RATINGS Nominal Operating Cell Temperature (NOCT) Temperature Coefficient of P - Temperature Coefficient of Voc Temperature Coefficient of Isc MAXIMUM RATINGS 45•C (t2•C) Operational Temperature -40-+85°C Maximum System 1000V DC(IEC)/ - 0.43%/°C _ _ voltage /'� 66000pV�DC(UL) -0.32%/°C` (max Series Fuse RCLI�j TING 0.04z] callffnem i WARRANTY ".. "it+ :. OL 4 ZU 114 10 year Product Workmanship Warranty 25 year Linear Power Warranty EVIE'IN D FOR CODE COMPI_t NCE (Please refer to product warranty for details) Rev ewed By. ,��•..r CERTIFICATION R �e SA„ PACKAGING CONFIGURATION � Modules per box: 24 pieces A C VL US Modules per 40' container: 672 pieces in PV CYCLE ~.. usun V Trinasolar CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT.cOSPAr, © 2013 Trina Solar Limited. All rights reserved. Specifications included in this datasheet are subject to change without notice. ti'v¢ �.� j Smart Energy Together 'cOMPPt�, I" 0 A'-44Ed�e as;gr g`� µ'00%) Key Features Quick and easy to install - dramatically reduces installation time Lower system costs - can cut rooftop installation costs in half • Aesthetic seamless appearance - low profile with auto leveling and alignment • Built-in hyper -bonded grounding system - if it's mounted, it's grounded • Theft resistant hardware • Ultra-low parts count - 3 parts for the mounting and grounding system • Industry first comprehensive warranty insurance by AM Best rated leading insurance companies in the world • Industry leading plus only power tolerance: 0 —+5W • Backward compatibility with all standard rooftop and ground mounting systems • Backed By Our New 10/25 Linear Power Warranty Plus our added 25 year insurance coverage 100% s7% AddedValueF sox rOm Warranty so% a% s 10 1s 20 25 �� CanadianSolar 10 year product warranty on materials and workmanship 25 year linear power output warranty Next Generation Solar Module NewEdge, the next generation module designed for multiple types of mounting systems, offers customers the added value of minimal system costs, aesthetic seamless appearance, auto groundingand theft resistance. The black -framed CS6P-PX is a robust 60 cell solar module incorporating the groundbreaking Zap compatible frame. The specially designed frame allows for rail -free fast installation with the industry's most reliable grounding system. The module uses high efficiency poly -crystalline silicon cells laminated with a white back sheet and framed with black anodized aluminum. The black -framed CS6P-PX is the perfect choice for customers who are looking for a high quality aesthetic module with lowest system cost. Best Quality • 235 quality control points in module production • EL screening to eliminate product defects • Current binning to improve system performance • Accredited Salt mist resistant Best Warranty Insurance • 25 years worldwide coverage • 100% warranty term coverage • Providing third party bankruptcy rights Non -cancellable • Immediate coverage • Insured by 3 world top insurance companies Comprehensive Certificates • IEC 61215, IEC 61730, IEC61701 ED2, UL1703, CEC Listed, CE and MCS • IS09001: 2008: Quality Management System • ISO/TS16949:2009: The automotive quality management system • IS014001:2004: Standards for Environmental management system • QC080000 HSPM: The Certification for Hazardous Substances Regulations • OHSAS 18001:2007 International standards for occupational health and safety • REACH Compliance www.canadiansolar.com CS6P-235/240/245/250/255PX Electrical Data STC CS6P-235P CS6P-240P CS6P-245P CS6P-250P CS6P-255PX Nominal Maximum Power (Pmax) 235W 240W 245W 250W 255W Optimum Operating Voltage (Vmp) 29.8V 29.9V 30.OV 30AV 30.2V Optimum Operating Current (Imp) 7.90A 8.03A 8.17A 8.30A 8.43A Open Circuit Voltage (Voc) 36.9V 37.OV 37.1V 37.2V 37AV Short Circuit Current (Ise) 8.46A 8.59A 8.74A 8.87A 9.00A Module Efficiency 14.61% 14.92% 1 15.23% 15.54% 15.85% Operating Temperature -40°C -+85•C Maximum System Voltage 1000V IEC /600V UL Maximum Series Fuse Rating 15A Application Classification ClassA Power Tolerance 0 - +5w Under Standard Test Conditions (STC) of irradiance of 1000WIm`, spectrum AM 1.5 and cell temperature of 25'C NOCT CS6P-235P CS6P-240P CS6P-245P CS6P-250PXCS6P-255PX Nominal Maximum Power Pmax 170W 174W 178W 181W 185W Optimum Operating Voltage (Vmp) 27.2V 27.3V 27.4V 27.5V 27.5V Optimum Operating Current (Imp) 6.27A 6.38A 6.49A 6.60A 6.71A Open Circuit Voltage (Voc) 33.9V 34.OV 34.1V 34.2V 34AV Short Circuit Current (Isc) 6.86A 6.96A 7.08A 7.19A 7.29A Under Normal Operating Cell Temperature. I rradiance of 800 Wlm', spectrum AM 1.5, ambient temperature 20'C, wind speed 1 m/s Mechanical Data Cell Type Poly -crystalline 156 x 156mm, 2 or 3 Busbars Cell Arrangement 60 (6 x 10) Dimensions 1638 x 982 x 40mm (64.5 x 38.7 x 1.57in) Weight 20.5kg (45.21bs) Front Cover 3.2mm Tempered glass Frame Material Anodized aluminium alloy J -BOX IP65, 3 diodes Cable 4mm'(IEC)/12AWG(UL), 1000mm Connectors MC4 or MC4 Comparable Standard Packaging (Modules per Pallet) 24pcs Module Pieces per container (40 ft. Container) 672pcs (40'HQ) I-V Curves (CS6P-255PX) •Specifications included in this datasheet are subject to change without prior notice. About Canadian Solar Canadian Solar Inc. Is one of the world's largest solar companies. As a leading vertically -integrated manufacturer of ingots, wafers, cells, solar modules and solar systems, Canadian Solar delivers solar power products of uncompromising quality to worldwide customers. Canadian Solar's world class team of professionals works closely with our customers to provide them with solutions for all their solar needs. EN.Re 10.17Copyngrl 1 2012 C ...than Solar Inc. Black -framed Temperature Characteristics Temperature Coefficient Pmax -0.43%rC I Voc -0.34 %/°C Ise 0.065 %rC Normal Operating Cell Temperature 45t2•C Performance at Low Irradiance Industry leading performance at low irradiation environment, +95.5% module efficiency from an irradiance of 1000w/m'to 200w/m' (AM 1.5, 25 -C) Engineering Drawings Reviewed By CUPERTINO Building Depatnent a i, 2 CODE COMPLIANCE Canadian Solar was founded In Canada In 2001 and was successfully listed on NASDAQ Exchange (symbol: CSIQ) in November 2006. Canadian Solar has module manufacturing capacity of 2.05GW and cell manufacturing capacity of 1.3GW. solar=ee SolarEdge Single Phasi For North America SE3000A-US / SE380OA-US / SE5000A SE760OA-US / SE1000OA-US / SE11400 i :everter W�rrantY �aivah��• The best choice for SolarEdge enabled systems Integrated arc fault protection (Type 1) for NEC 2011 690.11 compliance - Superior efficiency (98%) - Small, lightweight and easy to install on provided bracket - Built-in module -level monitoring - Internet connection through Ethernet or Wireless - Outdoor and indoor installation - Fixed voltage inverter, DC/AC conversion only - Pre -assembled AC/DC Safety Switch for faster installation - Optional - revenue grade data, ANSI C12.1 USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - ISRAEL www.solaredge.us solar=eeSingle Phase Inverters for North America 183 - 208 - 229 Vac SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE760OA-US / SE1000OA-US / SE1140OA-US 4Mir 3/4" minimum / 1-2 strings / 24-6 AWG 3 strings/ 14-6 AW SE3000A-US SE380_0A-US I SE5000A-US I SE6000A-US SE7600A-USI SE10000A- US I SE1140OA-US OUTPUT AC Output Voltage Min. -Nom. -Max.* i n /� rtme epa Switch (HxWxD) 775 x 315 x 172 775 x 315 x 191 ( ,, mm nt Weight with AC/DC Safety Switch 51.2/23.2 54.7 / 24.7^'`.8'.A / 40.1 9980 @ 208V Cooling Natural Convection h, --(use[ replaceable) Nominal AC Power Output 3000 3800 5000 6000 7600 10000 @240V 11400 VA Max. AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA 1 5450 @240V A 10950 @240V AC Output Voltage Min. -Nom. -Max.* _ - V _ 183 - 208 - 229 Vac 3/4" minimum / 24-6 AWG m / 8-3 AWG DC input conduit size / p of strings 4Mir 3/4" minimum / 1-2 strings / 24-6 AWG 3 strings/ 14-6 AW PER1%^ iNtr 9 , AC Output Voltage Min. -Nom. -Max.* i n /� rtme epa Switch (HxWxD) 775 x 315 x 172 775 x 315 x 191 ( ,, mm nt Weight with AC/DC Safety Switch 51.2/23.2 54.7 / 24.7^'`.8'.A / 40.1 211- 240 - 264 Vac' Cooling Natural Convection h, --(use[ replaceable) Noise <.25 < 50 , :60.5) AC Frequency Min. -Nom. -Max.* **;i S r -13 to +140 / -25 to +60 (CAN version i-40'taiawN E [ j f- vR CODE r� �,C��fV!PLI NCE 59.3 - 60 - 60.5 (with HI country setting 57 - 60 - NEMA 3R support. Reviewed ' B Hz Max. Continuous Output Current 12.5 16 ( 24 @ 208V 25 I 32 j 48 @ 248V 1 47.5 A GFDI 1 A Utility Monitoring, Islanding Protection, Country Configurable Yes Thresholds INPUT Recommended Max. OC Power** 3750 4750 6250 7500 9500 12400 14250 W (STC) Transformer -less, Ungrounded Yes . Max. Input Voltage 500 Vdc Nom. DC Input Voltage 325 @ 208V / 350 @ 240V Vdc Max. Input Current*** 9.5 I 13 16.5 @ 208V 18 23 15.5 @ 240V 33 @ 208V ( 30.5 @ 240V 34.5 Adc Max. Input Short Circuit Current 30 45 Adc Reverse -Polarity Protection Yes . Ground -Fault Isolation Detection 600ku Sensitivity . Maximum Inverter Efficiency 97.7 98.298.3 98.3 98 98 98 % CEC Weighted Efficiency 97.5 ( 9S 197.5 @ 201V 97.5 97.5 97 @ 208V 97.5 % 98 @ 240V 97.5 @ 240V Nighttime Power Consumption < 2.5 _ <4 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, RS232, Ethernet, ZigBee (optional) Revenue Grade Data ANSI C12.1 Optional STANDARD COMPLIANCE Safety UL1741, UL16996, UL1998 ,CSA 22.2 Grid Connection Standards IEEE1547 Emissions FCC part15 class 8 INSTALLATION SPECIFICATIONS AC output conduit size / AWG range 3/4" minimum / 24-6 AWG m / 8-3 AWG DC input conduit size / p of strings 4Mir 3/4" minimum / 1-2 strings / 24-6 AWG 3 strings/ 14-6 AW PER1%^ iNtr 9 AWG range Dimensions with AC/DC Safety ,.nttumf, 30.5 x 12.1.7 / 30.5 x 12.5 x 7.5 / 0 U I ( 10 / 775 x 315 x 260 i n /� rtme epa Switch (HxWxD) 775 x 315 x 172 775 x 315 x 191 ( ,, mm nt Weight with AC/DC Safety Switch 51.2/23.2 54.7 / 24.7^'`.8'.A / 40.1 Ib / kg Cooling Natural Convection h, --(use[ replaceable) Noise <.25 < 50 d BA Min. -Max. Operating Temperature Range **;i S r -13 to +140 / -25 to +60 (CAN version i-40'taiawN E [ j f- vR CODE r� �,C��fV!PLI NCE Protection Rating For other rregional tontaaSolarEdge r� � NEMA 3R support. Reviewed ' B . please •• Limited to 125% for locations where the yearly average high temperature is above 77'F/25'C and to 135% for locations where it is below 77'F/25'G Y' For detailed information, refer to ut A higher current source may be used; the inverter will limit its input current to the values stated '• - CAN P/Ns are eligible for the Ontario FIT and micmFiT (micmFIT exc. 5E11400A-US-CAN).