14100057 CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 6191 BOLLINGER RD CONTRACTOR:A BRIGHT IDEA PERMIT NO: 14100057
OWNER'S NAME: WEST VALLEY PRESBYTERIAN CHURCH 30093 AHERN AVE DATE ISSUED: 10/09/2014
OWNER'S PHONE: 4156409673 UNION CITY,CA 94587 PHONE NO:(510)487-5483
LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL ❑ COMMERCIAL ❑
t REMOVE AND REPLACE ALL LIGHTING FIXTURE AND
License Class Lie.# �7 EQUIPMENT
1
Contractor )q gel Date
1 hereby affirm that 1 am licensed under the provisions of Chapter 9
(commencing with Section 7000)of Division 3 of the Business&Professions
Code and that my license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
I have and will maintain a certificate of consent to self-insure for Worker's
Compensation,as provided for by Section 3700 of the Labor Code,for the
performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$20670
have and will maintain Worker's Compensation Insurance,as provided for by
Section 3700 of the Labor Code,for the performance of the work for which this
APN Number:37541007.00 Occupancy Type:
permit is issued.
APPLICANT CERTIFICATION
I certify that 1 have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED
correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DA RMIT ISSUANCE OR
to building construction,and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS FR M LAST CALLED INSPECTION.
indemnify and keep harmless the City of Cupertino against liabilities,judgments,
costs,and expenses which may accrue against said City in consequence of the 6
granting of this permit. Additionally,the applicant understands and will comply Issued by: Date: d
with all non-p nt source regulations per the Cupertino Municipal Code,Section
9.18.
RE-ROOFS:
Signat e - .¢—"�--+ Date q— All roofs shall be inspected prior to any roofing material being installed. If a roof is
installed without first obtaining an inspection,I agree to remove all new materials for
inspection.
❑ OWNER-BUILDER DECLARATION
Signature of Applicant: Dale:
1 hereby affirm that I am exempt from the Contractor's License Law for one of
the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER
1,as owner of the property,or my employees with wages as their sole compensation,
will do the work,and the structure is not intended or offered for sale(Sec.7044,
Business&Professions Code)
1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE
construct the project(Sec.7044,Business&Professions Code). 1 have read the hazardous materials requirements under Chapter 6.95 of the
California Health&Safety Code,Sections 25505,25533,and 25534. I will
1 hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the
declarations: Health&Safety Code,Section 25532(a)should 1 store or handle hazardous
I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should 1 use equipment or devices which emit hazardous
Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District 1
performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and
I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sect' ns 255 5533,and 25534.
Section 3700 of the Labor Code,for the performance of the work for which this
Owner or authorized agent: Date:
permit is issued.
1 certify that in the performance of the work for which this permit is issued,I shall
not employ any person in any manner so as to become subject to the Worker's
Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY
become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of
forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.)
Lender's Name
APPLICANT CERTIFICATION Lender's Address
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction,and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes.(We)agree to save
indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION
costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records.
granting of this permit.Additionally,the applicant understands and will comply
with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional
9.18.
Date
GIENERAL PERMIT A.PPLICATION El��
COPJMUN1TY DEVELOPMENT DEPAR71VENI• BUILDING DIVIS101;
10300 TORRE AVENUE• CUPERTINO, CA 95014-32-55 1
_ (408) 777-3228 • r?x (4G8)777-3333•buildino(�cuc� ino.Dra
CUr0'f;i jK0
m I s
❑PLUMBINIGJl Cr-1�iCAL ❑azc-1-jc S
qfc-w,,f�DP SS
=1 e, ST —IE,Zi.'. I F
cme,ST.h-, Z2 FA--
CR'.n� ❑ CJ,��r:3L�._D3. L-1�G`3,7,1.��«ni ❑ CCT' hCC•OR ❑COTit�hCTvR�.CTi ❑ pAC-_=CT ❑=?.0-=��R ❑ D1•�0?"'�, ❑ '�.tT'I
CO? hCIOR?Aim �R+��LD(1a L C 1 S'c?iJ,r I L1C ;S'c-'i?= 131iS.UC 4
CO?JDA MY T.t t r � =-i✓ey FAX
ST-t c.Z-r Y-MR=Ss c=, ,STA i q Z3 PHONE
P RC vinCi/rTGTrERT�]✓" L CTsE?.TUA1SER BLJs.LIC R
CO?J9fRYT 4✓S I 1✓�hTs I aAX
ST?c:T hDDP=SS CITY,STAT F,ZP I P_OKE.
US2 OF ❑_sm or D.pT--.. ❑ mau-F'U'u Y PROJECT LTi WILDLf?NTD ❑ l m PP.OrtCT T ❑m I IST-BLDG 1.N ❑ 1 LS
BLT N01. ❑COlz�CL',L L?3!ND, 'rhe a.EA ❑ \,o :iOCDM?=- ❑ ,o =iGTi 807 ? ❑ \'0
nESMUTION of WORK
y-y s r a se belo;,,I ce, to e_Cii Of tae rollov,L : I am u,_ -er or udoriz.5d€gaat to act on t:_ ro o,,;mz t`s bthalf. I hF%:t;tad phis
application and tae inior-ation I have Prov;_cd is co-ect I have s_ad t:-,e Description Of��` ,k and v>_riry it is G c raLB, 1 F P.P.to conpIy Width all applicable local
ordinances pads to la,;s,elaa e to buildine corse_cticn. Int ives of Cuper:iao:o eater&,,e abo---identtij-�'ed proptgty`or i s-niction p�_rpeses.
S:--mature oi=.palic ,t' _ent: y a Date: — 1 CJI t'
SUPT F7 r?�T T 't0���� 0?v! F.QU=�.Di = — M.
L!
IMP
P _
_ _ •- _ S^
R.
?, P.%,�fsc.Ea�_201.1.docre-,,ised 06/21/11
CITY OF CUPERTINO
FEE ESTIMATOR-BUILDING DIVISION
MDDRESS: 6191 bollinger rd DATE: 10/09/2014 REVIEWED BY: Mendez
PN: BP#: `VALUATION: 1$20,670
PERMIT TYPE: Building Permit PLAN CHECK TYPE: Tenant Improvement
PRIMARY Commercial Building PENTAMATION 1GENCOM
USE: PERMIT TYPE:
WORK remove and replace all lighting fixture and equipment
SCOPE
F-1 _L_ LJ -t- LJ -L_
NOTE: This estimate does not include fees clue to other Departments(i.e.Planning,Public Works, Fire,Sanitary Sewer District,School
District,etc. . These ees are based on the preliminar information available and are only an estimate. Contact the De t or addn'l info.
FEE ITEMS (FeeResolution ll-0 3 r'' i:'1%13) FEE QTY/FEE MISC ITEMS
Plan Check Fee: Hourly Only? ®Yes ) No $0.00 1 hours Plan Check,Hourly
Suppl. PC Fee: Q Reg. 0 OT 10—.01hrs $0.00 $143.00 ISTPLNCK
PME Plan Check: $0.00
Permit Fee: Hourly Only? ®Yes Q No $0.00
Suppl. Insp. Fee:Q Reg. Q OT 0--.01hrs $0.00
PME Unit Fee: $0.00
PME Permit Fee: $0.00
Work Without Permit? 0 Yes (E) No $0.00
.Advanced Planning Fee: $0.00 Select a Non-Residential Q
Building or Structure
Strom Motion Fee: IBSEISMICO $5.79 3.0 hrs Inspections
Bldg,Stds Commission Fee: IBCBSC $1.00 $429.00 ISTINSP Inspection,Hourly
SUBTOTALS: $6.79 $572.00 TOTAL FEE: $578.79
Revised: 08/20/2014
STATE OF CALIFORNIA
INDOOR LIGHTING
CEC-NRCI-LTI-01-E Revised 06/13 CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF INSTALLATION NRCI-LTI-01-E
Indoor Lighting (Page 1 of 2)
Project Name:West Valley Presbyterian Church Enforcement Agency:Cupertino(City) Permit Number.
Project Address:6191 Bollinger Rd. ""Cupertino Z'P`°de 95014
GENERAL INFORMATION
DATE OF BUILDING PERMIT PERMIT#
BUILDING TYPE 0 Nonresidential ❑ High-Rise Res(Common Area) ❑ Hotel/Motel(Common Area)
PHASE OF
ElCONSTRUCTION New Construction ❑Addition Q El Unconditioned
SCOPE OF RESPONSIBILITY
Enter the date of approval by enforcement agency of the Certificate of Compliance that provides Date:
the specifications for the energy efficiency measures for the scope of responsibility for this
Installation Certificate.
In the table below identify all applicable construction documents that specify the requirements for the scope of
responsibility reported by this Installation Certificate(continued).
Date Approved By
Document Title or Description Applicable Sheets or Pages,Tables,Schedules,etc. the Enforcement
Agency
Lighting Certificate of Compliance
Lighting Controls Certificate of Compliance
Lighfing Power Allowance Certificate of Compliance
Lighting Controls Certificate of Acceptance
Lighting Controls Certificate of Installation
Oq` F F I G F. C;0 P Y
CA Building Energy Efficiency Standards-2013 Nonresidential Compliance June 2013
STATE OF CALIFORNIA
INDOOR LIGHTING 4
CEC-NRCI-LTi-01-E Revised 06113 CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF INSTALLATION NRCI-LTI-01-E
Indoor Lighting (Page 2 of 2)
Project Name:West Valley Presbyterian Church Enforcement Agency:Cupertino (City) Permit Number.
Project Address:6191 Bollinger Rd. ""'Cupertino Z'p`°de95014
Date Approved By
Document Title or Description Applicable Sheets or Pages,Tables,Schedules,etc. the Enforcement
Agency
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Installation documentation is accurate and complete.
Documentation uthor ame: Documentation Author gna re:
Documentation Au or Comp ny N_me:r.�- Date Signed:
ILA
Address: 3 _( CEA/HERS Certification Identification(If applicable):
City/State/TP—. _ t C\`� Phone: i�1 J_- 1
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury,under the laws of the State of California:
1. The information provided on this Certificate of Installation is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the
system design,construction,or installation of features,materials,components,or manufactured devices for the scope of work
identified on this Certificate of Installation and attest to the declarations in this statement(responsible builder/installer),
otherwise I am an authorized representative of the responsible builder/installer.
3. The constructed or installed features,materials,components or manufactured devices(the installation)identified on this
Certificate of Installation conforms to all applicable codes and regulations,and the installation conforms to the requirements
given on the plans and specifications approved by the enforcement agency.
4. 1 reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements
for the scope of construction or installation identified on this Certificate of Installation,and I have ensured that the requirements
that apply to the construction or installation have been met.
5. 1 will ensure that a completed signed copy of this Certificate of Installation shall be posted,or made available with the building
permit(s)issued for the building,and made available to the enforcement agency for all applicable inspections.I understand that a
completed signed copy of this Certificate of Installation is required to be included with the documentation the builder provides to
the building owner at occupancy.
Responsible Builder/Installer Name: Responsible Builder/Installer Si ture:
Company Name: nst g Subcontract� neral Contractor or Position With ompany Title):
Builder/Owner) (� C L 0 yp-y e-r
Address: ,r'�_�� r _I;Xu CSLB License:
City/State/V +� �f Phng`o Date Signed: `
CA Building Energy Efficiency Standards-2013 Nonresidential Compliance June 2013
STATE OF CALIFORNIA
AUTOMATIC DAYLIGHTING CONTROL ACCEPTANCE DOCUMENT -
CEC-NRCA-LTI-03-A Revised 06113 CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF ACCEPTANCE NRCA-LTI-02-A
Lighting Control Acceptance Document (Page 1 of 6)
F
Project Name:West Valley Presbyterian Church Enforcement Agency'Cupertino Permit Number
Project Address:6191 Bollinger Rd. °"Cupertino Zip Code:94014
Note: For more than 3 spaces attach additional sets of pages 2 Enforcement Agency Use: Checked by/Date
through 5,as required.
Automatic Shut-off Controls: Automatic Time Switch Control and Occupant Sensor
Intent: Lights are turned off or set to a lower level when not needed per Section 110.9(a)&130.1(c).
Guidance
This acceptance test form must be filled out for all newly-installed lighting control systems of the following types:
1. Automatic Time Switch Controls
II. Occupancy Sensors
III. Partial-OFF occupancy sensors
IV. Partial-ON occupancy sensors(only if used to claim a Power Adiustment Factor)
V. Occupancy Sensors serving small zones in large open plan offices(only if used to claim a Power Adjustment Factor)
For automatic daylighting controls use acceptance test form NRCA-LTI-03-A;for demand responsive lighting controls,use
acceptance test form NRCA-LTI-04-A.
The tests on this certificate are required by Section 140.6(a)2 and 130.4(a)of the Building Energy Efficiency Standards 2013. The
tests themselves are described in Sections 140.6(a)2 and in Reference Appendix NA7.6.
A. Construction Inspection
Fill out Section A to cover spaces 1 through 3 that are functionally tested under Section B. Make as many copies of pages 2-5 as
are required to test all spaces in the building,and attach to page 1.
Instruments needed to perform tests include,but are not limited to:hand-held amperage meter,power meter,or light meter
1 Automatic Time Switch Controls Construction Inspection—confirm for all listed in Section B
a. All automatic time switch controls are programmed for(check all):
�] Weekdays
Weekend
❑� Holidays
b. Document for the owner automatic time switch programming(check C
UPERTINO
0 Weekdays settings ,�� �
<�f �� ' Buildinq
.
aitment
�] Weekend settings
r
❑� Holidays settings
❑ Set-up settings la- -
0 Preference program setting
❑? Verify the correct time and date is properly set in the time switch
Verify the battery is installed and energized
❑? Override time limit is no more than 2 hours
Occupant Sensors and Automatic Time Switch Controls have been certified to the Energy Commission in
accordance with the applicable provision in Section 110.9 of the Standards,and model numbers for all such
controls are listed on the Commission database as Certified Appliance and Control Devices
2 Occupancy Sensor Construction Inspection—confirm for all listed in Section B
CA Building Energy Efficiency Standards-2013 Nonresidential Compliance lune 2013
STATE OF CALIFORNIA Ak
AUTOMATIC DAYLIGHTING CONTROL ACCEPTANCE DOCUMENT
CEC-NRCA-LTI-03-A Revised 06113 CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF ACCEPTANCE NRCA-LTI-02-A
Lighting Control Acceptance Document . (Page 2 of 6)
�
pro' Nam:West Valley Presbyterian Church Enforcement Agency.Cupertino
lino Permit Number.
Pm;ect Address:6191 Bollinger Rd. °11-Cupertino Zip Code:94014
Q Occupancy sensors are not located within four feet of any HVAC diffuser
Q Ultrasonic occupancy sensors do not emit audible sound 5 feet from source
B. Functional Testing of Lighting Controls
Representative Spaces Selected
For every space in the building,conduct functional tests I through V below if applicable.If there are several geometrically similar
spaces that use the same lighting controls,test only one space and list in the cells below which"untested spaces"are
represented by that tested space.
EXCEPTION:For buildings with up to seven(7)occupancy sensors,all occupancy sensors shall be tested.(NA7.6.2.3)
Tested space/room name: Space Type(office,corridor,etc)
❑? 1
Untested areas/rooms
Tested space/room name: Space Type(office,corridor,etc)
2
Untested areas/rooms
Tested space/room name: Space Type(office,corridor,etc)
❑� 3
Untested areas/rooms
Functional Tests Tested Space Number
Confirm compliance(Y/N)for all control system types(I-V)present in each space:
1.Automatic Time Switch Controls 1 2 3
Step 1:Simulate occupied condition
a. All lights can be turned on and off by their respective area control switch Y/N Y/N Y/N
b Verify the switch only operates lighting in the ceiling-height partitioned area in Y/N Y/N Y/N
which the switch is located
Step 2:Simulate unoccupied condition
a All lighting,including emergency and egress lighting,turns off. Exempt lighting may Y/N Y/N Y/N
remain on per Section 130.1(c)1 and 130,1(a)1.
Manual override switch allows only the lights in the selected ceiling height
b. partitioned space where the override switch is located and remain on no longer Y/N Y/N Y/N
than 2 hours(unless serving public areas and override switch is captive key type).
Step 3:System returned to initial operating conditions Y/N Y/N Y/N
2.Occupancy Sensors 1 2 3
Step 1:Simulate an unoccupied condition
a Lights controlled by occupancy sensors turn off within a maximum of 30 minutes Y/N Y/N Y/N
from start of an unoccupied condition per Standard Section 110.9(a)
The occupant sensor does not trigger a false"on"from movement in an area
b. adjacent to the controlled space or from HVAC operation Y/N Y/N Y/N
Step 2:Simulate an occupied condition
a. Status indicator or annunciator operates correctly Y/N Y/N Y/N
CA Building Energy Efficiency Standards-2013 Nonresidential Compliance June 2013
STATE OF CALIFORNIA _s
AUTOMATIC DAYLIGHTING CONTROL ACCEPTANCE DOCUMENT `
CEC-NRCA-LTI-03-A Revised 06113) CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF ACCEPTANCE NRCA-LTI-02-A
Lighting Control Acceptance Document F (Page 3 of 6)
Project Name:West Valley Presbyterian Church Enforcement Agenry:Cupertino Permit Number:
Project Address:6191 Bollinger Rd. ""Cupertino Zip`ode.94014
Lights controlled by occupancy sensors turn on immediately upon an occupied
b, condition OR sensor indicates space is"occupied"and lights may be turned on Y/N Y/N Y/N
manually
Step 3:System returned to initial operating conditions Y/N Y/N Y/N
CA Building Energy Efficiency Standards-2013 Nonresidential Compliance June 2013
STATE OF CALIFORNIA
AUTOMATIC DAYLIGHTING CONTROL ACCEPTANCE DOCUMENT
CEC-NRCA-LTI-03-A(Revised 06113) CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF ACCEPTANCE NRCA-LTI-02-A
Lighting Control Acceptance Document (Page 4 of 6)
Pmje�tName West Valley Presbyterian Church Entc—mentAgency:Cuperl:ino Permit Number:
oject Address:6191 Bollinger Rd. ""Cupertino Zip Code:94014
3. Partial Off Occupancy Sensor 1 2 3
Step 1:Simulate an unoccupied condition
a'
Lights go to partial off state within a maximum of 30 minutes from start of an / /unoccupied condition per Standard Section 110.9(a) Y N Y N Y/N
The occupant sensor does not trigger a false"on"from movement in an area
adjacent to the controlled space or from HVAC operation.For library book stacks or
b' warehouse aisle,activity beyond the stack or aisle shall not activate the lighting in Y/N Y/N Y/N
the aisle or stack.
In the partial off state,lighting shall consume no more than 50%of installed lighting
power,or:
• No more than 60%of installed lighting power for metal halide or high
pressure sodium lighting in warehouses.
C. • No more than 60%of installed lighting power for corridors and stairwells in Y/N Y/N Y/N
which the installed lighting power is 80 percent or less of the value allowed
under the Area Category Method.
Light level may be used as a proxy for lighting power when measurements are taken
Step 2:Simulate an occupied condition
rhe occupant sensing controls shall turn lights fully ON in each separately controlled / /
a' areas,Immediately upon an occupied condition Y N Y/N Y N
4. Partial On Occupancy Sensors 1 2 3
Step 1.-Simulate an occupied condition.Verify partial on operation.
a Immediately upon an occupied condition,the first stage activates between 30 to 70°x6 Y/N Y/N Y/N
of the lighting automatically.
After the first stage occurs, manual switches allow an occupant to activate the
b. alternate set of lights,activate 100%of the lighting power,and manually deactivate Y/N Y/N Y/N
all of the lights.
Step 2. Simulate an unoccupied condition
a' IBoth stages(automatic on and manual on)lights turn off within a maximum of 30
minutes from start of an unoccupied condition per Standard Section 110.9(a) Y/N Y/N Y/N
13, The occupant sensor does not trigger a false"on"from movement in an area adjacent Y/N Y/N Y/N
to the controlled space or from HVAC operation
S. Additional test for Occupancy Sensors Serving Small Zones in Office Spaces Larger 1 2 3
than 250 Square Feet,to Qualify for a Power Adjustment Factor(PAF)
First,complete Functional Test 2(above)for each controlled zone
Step 1. Verify area served and compare actual PAF with claimed PAF. Refer to Functional Test II.
a. Area served by controlled lighting(square feet)
b Enter PAF corresponding to controlled area from line(a)above(<125sf for PAF=0.4,
126-250sf for PAF=0.3,251-500sf for PAF=0.2).
Enter PAF claimed for occupant sensor control in this space from the Certificate of
C. Compliance
d' Y
The PAF corresponding to the controlled area(line b),is less than or equal to the PAF /N Y/N Y/N
claimed in the compliance documentation(line c)
e' Y
Sensors shall not trigger in response to movement in adjacent walkways or /N Y/N Y/N
workspaces.
CA Building Energy Efficiency Standards-2013 Nonresidential Compliance June 2013
STATE OF CALIFORNIA
AUTOMATIC DAYLIGHTING CONTROL ACCEPTANCE DOCUMENT ..
CEC-NRCA-LTI-03-A Revised 06113 CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF ACCEPTANCE NRCA-LTI-02-A
Lighting Control Acceptance Document (Page 5 of 6)
Project Name: rnforcement Agency:CLlpel.}ino Perm it Number:
West Valley Presbyterian Church
Project Address:6191 Bollinger Rd. "Cupertino Z`PCode:94014
All steps are conducted in Functional Test 2"Occupancy Sensor (On Off Control)"and / /
f' all answers are Yes(Y) Y/N Y N Y N
C Testing Results
PASS/ PASS/ PASS/
FAIL FAIL FAIL
I Automatic Time Switch Controls (all answers must bey).
II Occupancy Sensor(On Off Control)(all answers must be Y).
III Partial Off Occupancy Sensor(all answers must be Y). For warehouses, library book
stacks,corridors,stairwells in nonresidential buildings must also be accompanied by
passing Test I or Test II.
IV Partial On Occupant Sensor for PAF(all answers must be Y).
V Occupant Sensor serving small zones for PAF(all answers must be Y).Also must pass
Test II
D. Evaluation :
0 PASS:All applicable Construction Inspection responses are complete and all applicable Equipment Testing Requirements
responses are positive(Y-yes)
CA Building Energy Efficiency Standards-2013 Nonresidential Compliance June 2013
STATE OF CALIFORNIA
AUTOMATIC DAYLIGHTING CONTROL ACCEPTANCE DOCUMENT
CEC-NRCA-LTI-03-A Revised 06113 CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF ACCEPTANCE NRCA-LTI-02-A
Lighting Control Acceptance Document (Page 6 of 6)
Project Name: Enforcement Agency: Permit Number:
West Valley Presbyterian Church Cupertino
Project Address:6191 Bollinger Rd. ``"-Cupertino Zip code:94014
Documentation author's Declaration Statement
1. t certify that this Certificate of Acceptance documentation is accurate and complete.
Documentation Author Name: Documentation Author Signature:
Documentation Author Company Name: Date Signed:
Address: CEA/HERS/ATT Certification Identification(if applicable):
City/State/Zip: Phone:
FIELD TECHNICIAN'S DECLARATION STATEMENT
I certify the following under penalty of perjury,under the laws of the State of California:
1. The information provided on this Certificate of Acceptance is true and correct.
2. 1 am the person who performed the acceptance verification reported on this Certificate of Acceptance(Field Technician).
3. The construction or installation identified on this Certificate of Acceptance complies with the applicable acceptance requirements
indicated in the plans and specifications approved by the enforcement agency,and conforms to the applicable acceptance requirements
and procedures specified in Reference Nonresidential Appendix NA7.
4. 1 have confirmed that the Certificate(s)of installation for the construction or installation identified on this Certificate of Acceptance has
been completed and signed by the responsible builder/installer and has been posted or made available with the building permit(s)
issued for the building.
Field Tevknifkian NamL 49Field Technician Sig17k 0%.ir n
Field Technician Qmpany Name: t_ Pos tionwi h Company(Tftl�tc'f- Y�
Address: ,es S � Gy-Z ATT Certification identification Cif applicable):
City/Stati ' Date Signed:
r
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury,under the laws of the State of California:
1. 1 am the Field Technician,or the Field Technician is acting on my behalf as my employee or my agent and I have reviewed the
information provided on this Certificate of Acceptance.
2_ 1 am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system
design,construction or installation of features,materials,components,or manufactured devices for the scope of work identified on this
Certificate of Acceptance and attest to the declarations in this statement(responsible acceptance person).
3. The information provided on this Certificate of Acceptance substantiates that the construction or installation identified on this
Certificate of Acceptance complies with the acceptance requirements indicated in the plans and specifications approved by the
enforcement agency,and conforms to the applicable acceptance requirements and procedures specified in Reference Nonresidential
Appendix NA7.
4. 1 have confirmed that the Certificate(s)of Installation for the construction or installation identified on this Certificate of Acceptance has
been completed and is posted or made available with the building permit(s)issued for the building.
5. 1 will ensure that a completed,signed copy of this Certificate of Acceptance shall be posted,or made available with the building
permit(s)issued for the building,and made available to the enforcement agency for all applicable inspections. I understand that a
signed copy of this Certificate of Acceptance is required to be included with the documentation the builder provides to the building
owner at occupancy.
Responsible Acceptance PprSon Responsible Acceptance Person Sign t e:
Responsible Accep a Person omQany 0-it Position with Company(Title):
Address: CSLB Licens%-) l J
City/State/Z�ip��� I Ph Date Si ned:
tire-( (� �—
CA Building Energy Efficiency Standards-2013 Nonresidential Compliance June 2013
I
toewltificate
This certificate is presented to.,
Mark W Spahn
TC-A813540
For successfully completing the requirements for the
ftfornia Advanced Lighting Controls Trainhm.g Program,
Acceptance Technic fan requirements
February 7;2014
Date Training Director
February 7, 2015
Expiration Date
� 'PG&E Corporation.
CAlfPOfWlA LIGFfTINO TACHNC�I,C�Y C�v'!CR � ' � �.���__
Uq
Wgj�
NLUe+wmt`w
�+a d'
The Silicon Valley Energy watch Program is implementedtby
h Silicon Valley Energy Watch
Ecology Action and funded by California ratepayers under the
I °[, �'''•- " 'Y
auspices of the California Public Utility Commission. Energy Efficiency Program t
Change Order#: Contractor Work Order Agreement
2 Energy and Cost Saving Projects
West Valley Presbyterian Church - MLTG (CO#2)
Property: West Valley Presbyterian Church
6191 Bollinger Rd.
Cupertino,CA 95014
Presented To: Bill Johns
6191 Bollinger Rd.
Cupertino,CA 95014
(415)640-9673
Email:
Contractor: ABI Services Inc L04" FFICE O
30093 Ahern Ave.
Union City,CA 94587
(800)650-5483
Report Date: 9/19/2014
Presented by: For questions contact the Installation Manager:
Jack Lu Rachel Radcliffe
Ecology Action Ecology Action
2672 Bayshore Parkway#505 2672 Bayshore Parkway#505
Mountain View, CA 94043 Mountain View, CA 94043
Phone: Phone:(831)515-1304 ext 104
Mobile:+1 4152653707 Mobile:+1 6507667006
Fax:(831)427-1368 Fax:650-210-9953
Email:jlu@ecoact.org Email:rradcliffe@ecoact.org
Page 1 Contractor Change Order 9/19/2014
The Silicon Valley Energy watch Program is implementedtby
h Silicon Valley Energy Watch
Ecology Action and funded by California ratepayers under the 9# � -A C .�,I },,,
auspices of the California Public Utility Commission. Energy Efficiency Program
Change Order#: Summary of Recommended Energy Efficiency Upgrades
2 West Valley Presbyterian Church - MLTG (CO#2)
West Valley Presbyterian Church
6191 Bollinger Rd.
Cupertino,CA 95014
Estimated Costs Estimated Annual Payback
Savings
Total installed cost Before rebate $22,047.49
Total Rebate $20,670.01
Your final cost After rebate $1,377.48 $7,920.69- 0.17 Years
The project cost is based on current equipment prices and rebate levels and is valid for a period of 14 days from the date presented.
Deemed kWh Demand Electricity
vi .* ( k1 Why Gas(Therm) Water(ccf) Sewer(ccf)$ Annual Month
Utility Savings Summary 71,795.79 27.98 42,869.87 0.00 $7,920.69 $660.06
By implementing these efficiency upgrades you will reduce the emissions of CO2(carbon dioxide) into the atmosphere by 22,463.81 Ib/yr
*Note-Savings are estimated using standard engineering calculations and are based on the hours of operation as described to the surveyor. Depending on actual usage as well as
changes in your electric utility rate,your savings may be higher or lower.The savings indicated above are NOT guaranteed. Construction costs may vary slightly depending on
fixture quantities and unforeseen conditions.
**Note-Based on DEER property type and measure savings values from the CPUC,this project is deemed to deliver 71795.79 kWh and 27.98 kW. The rebate offered for the
project is calculated based on the deemed savings values.
Page 2 Contractor Change Order 9/19/2014
The Silicon Valley Energy Watch Program is implemented Silicon Valley Energy Watch
Ecology Action and funded by California ratepayers under the , , _.."
Ener Efficiency Program i t ( " '4°-I ''
auspices of the California Public Utility Commission. 9Y Y 9
Change Order#: Energy Efficiency Projects and Equipment List
2 West Valley Presbyterian Church - MLTG (CO#2)
West Valley Presbyterian Church
6191 Bollinger Rd.
Cupertino,CA 95014
Recommended Energy Efficiency Upgrades Quantity Equipment Cost(Per Labor Hrs/Cost(PerItem) Item)
Area: (1) Sanctuary
Area Comment:
INC 200A/LED PAR38 19W 36DEG 3000K(90W equiv) (Philips) : [729.96]-Hours=7.ox2.0
Access Difficulty:
Custom Component 1 (30) (30 Annual Savings=$768.ia/yr Standard Ceiling Height:ht' > 18 ft
Rate Multiplier: 1.0 Rate Multiplier: 1.43
Installation Comment: Total Install Cost=$1,631.86
E1.LED PAR38 19W 36DEG 3000K(90W equiv)(Philips) 30.0 $36.06 0.08/$6.00
E2.Custom Component 1 30.0 $3.00 0/$0.00
INC 150W/LED PAR30 Short Neck 12W 36DEG 3000K (Philips) : [729.96]-Hours=7.ox2.0
Access Difficulty: Ceiling Height: > 18 ft
Custom Component 2 (20) (20) Annual Savings=$390.44/yr Standard g g
Rate Multiplier: 1.0 Rate Multiplier: 1.54
Installation Comment: Total Install Cost=$1,110.72
E1.LED PAR30 Short Neck 12W 36DEG 3000K(Philips) 20.0 $36.44 0.08/$6.00
E2.Custom Component 2 20.0 $3.00 0/$0,00
[729.96]-Hou rs=7.0x2.0
INC 175w A/LED PAR38 19W 36DEG 3000K(90W equiv) (Philips) :
Custom 2 Component 30 30 Access Difficulty:
p ( ) ( ) Standard Ceiling Height: > 18 ft
Page 3 Contractor Change Order 9/19/2014
Installation Comment: Annual Savings=$662.04/yr Rate Multiplier: 1.0 Rate Multiplier: 1.43
Total Install Cost=$1,631.86
E1.Custom Component 2 30.0 $3.00 0/$0.00
E2.LED PAR38 19W 36DEG 3000K(90W equiv)(Philips) 30.0 $36.06 0.08/$6.00
Area: (2) Prayer Room
Area Comment:
[729.96]-Hours=7.0x2.0
INC 60A/LED A-Lamp 11W 2700K(60W equiv) (Philips)(14) (14) Access Difficulty: Ceiling Height: <9 ft
Annual Savings=$97.04/yr Standard Rate Multiplier: 1.0
Installation Comment:(8)in the Sanctuary Forward,(2)In the Sacristy Room. Rate Multiplier: 1.0
Total Install Cost=$373.10
E1. LED A-Lamp 11 W 2700K(60W equiv)(Philips) 14.0 $17.49 0.08/$6.00
Area: (3) Crash Zone Room
Area Comment:
T12 4' 40S 3L -(PG&E)/T8 4' 32W 2L LBP Dual Switch Step-Dim : [2346.3]-Hours=5.0x9.0
Access Difficulty: Ceiling Height: <9 ft
Control: Gang 2 G (8) (8) Annual Savings=$266.13/yr Standard g g
Rate Multiplier: 1.0 Rate Multiplier: 1.0
Installation Comment: Total Install Cost=$1,625.53
E1.Ballast Disconnect 16.0 $0.70 0/$0.00
E2.Recycle: Fluorescent Lamps 4'or Shorter 24.0 $0.70 0/$0.00
E3. Lamp T8 4'32W 16.0 $4.44 0/$0.00
E4.Ballast Bi-Level 1&2 Lamp QuickStep LBF 8.0 $30.43 0.33/$24.75
E5.Control:Gang 2 Gang Cover Plate 6.0 $5.00 0/$0.00
E6.Recycle:Non-PCB Ballast from 4'or Shorter 16.0 $0.00 0/$0.00
E7.Reflector Troffer:2'x4'for 2L 8.0 $15.31 0.08/$6.00
E8.Control Wall Sensor Dual Switch 6.0 $79.40 0.5/$37.50
Page 4 Contractor Change Order 9/19/2014
T12-4'-34w-4L-MagES-RS-NLO/T8 4' 32W 2L NBF Continuous Dim : [52.14]-Hours=1.0x1.0
Control: Gang 2 Ga (1) (1) Access Difficulty: Ceiling Height: <9 ft
Annual Savings=$0.86/yr Standard Rate Multiplier: 1.0
Rate Multiplier: 1.0
Installation Comment:C0#1-Youth storage room Total Install Cost=$217.78
E1.Ballast Disconnect 1.0 $0.70 0/$0.00
E2.Lamp T8 4'32W 2.0 $4.44 0/$0.00
E3.Ballast Dimmable Quicktronic 2-lamp T8 NBF 1.0 $44.11 0.33/$24.75
E4.Control:Gang 2 Gang Cover Plate 1.0 $5.00 0/$0.00
E5.Control Wall Sensor 1.0 $69.44 0.5/$37.50
E6.Recycle:Non-PCB Ballast from 4'or Shorter 2.0 $0.00 0/$0.00
E7.Recycle:Fluorescent Lamps 4'or Shorter 4.0 $0.70 0/$0.00
[2346.3]-Hours=5.0x9.0
T12-4'-34w-2L-MagES-RS-NLO/T8 4' 32w 2L LBF (1) (1) Access Difficulty: Ceiling Height: <9 ft
Annual Savings=$10.53/yr Standard
Installation Comment:C0#1 Rate Multiplier: 1.0 Rate Multiplier: 1.0
Total Install Cost=$56.35
E1.Ballast:T8-2L,IS,LBF 1.0 $14.95 0.33/$24.75
E2.Ballast Disconnect 1.0 $0.70 0/$0.00
E3.Lamp T8 4'32W 2.0 $4.44 0/$0.00
E4.SFL 5000°K Specification $0.00 0/$0.00
E5.Recycle:Fluorescent Lamps 4'or Shorter 2.0 $0.70 0/$0.00
E6.Recycle:Non-PCB Ballast from 4'or Shorter 1.0 $0.00 0/$0.00
Area: (6) Nursery 1
Area Comment:
[2346.3]-Hours=5.0x9.0
T12 4' 40S 4L -PG&E/T8 4'32W 2L LBF Dual Switch Step-Dim : Access Difficulty.
Control: Gang 2 Gan (8) (8) Standard Ceiling Height: <9 ft
Page 5 Contractor Change Order 9/19/2014
Installation Comment: Annual Savings=$441.12/yr Rate Multiplier: 1.0 Rate Multiplier: 1.0
Total Install Cost=$3,559.83
E1.Reflector Troffer:2'x4'for 2L 8.0 $15.31 0.08/$6.00
E2.Recycle:Fluorescent Lamps 4'or Shorter 32.0 $0.70 0/$0.00
E3.Recycle:Non-PCB Ballast from 4'or Shorter 16.0 $0.00 0/$0.00
E4.Ballast Disconnect 16.0 $0.70 0/$0.00
E5.Lamp T8 4'32W 16.0 $4.44 0/$0.00
E6.Ballast Bi-Level 1&2 Lamp QuickStep LBF 8.0 $30.43 0.33/$24.75
E7.Control Wall Sensor Dual Switch 20.0 $79.40 0.5/$37.50
E8.Control:Gang 2 Gang Cover Plate 20.0 $5.00 0/$0.00
Area: (7) Nursery 2
Area Comment:
T12 4' 40S 4L -PG&E/T8 4' 32W 2L LBF Dual Switch Step-Dim : [2346.3]-Hours=5.0x9.0
Access Difficulty: Ceiling Height: <9 ft
Control: Gan 2 Gan 8 8 9 9
9 � ) � ) Annual Savings=$441.12/yr Standard
Rate Multiplier: 1.0 Rate Multiplier. 1.0
Installation Comment: Total Install Cost=$805.12
E1.Reflector Troffer:2'x4'for 2L 8.0 $15.31 0.08/$6.00
E2.Recycle:Fluorescent Lamps 4'or Shorter 32.0 $0.70 0/$0.00
E3.Recycle:Non-PCB Ballast from 4'or Shorter 16.0 $0.00 ', 0/$0.00
E4.Ballast Disconnect 16.0 $0.70 0/$0.00
E5.Lamp T8 4'32W 16.0 $4.44 0/$0.00
E6.Ballast Bi-Level 1&2 Lamp QuickStep LBF 8.0 $30.43 0.33/$24.75
E7.Control Wall Sensor Dual Switch 0.0 $79.40 0.5/$37.50
E8.Control:Gang 2 Gang Cover Plate 0.0 $5.00 0/$0.00
Page 6 Contractor Change Order 9/19/2014
Area: (8) Nursery Bathroom
Area Comment:Area Exempt from T24,less than 100 sq ft
(52.14]-Ho urs=1.Ox 1.0
T12 4' 40S 4L -PG&E/T8 4' 32w 2L LBF w/Reflector(1) (1) Access Difficulty: Ceiling Height: <9 ft
Annual Savings=$1.20/yr Standard Rate Multiplier: 1.0
Installation Comment: Rate Multiplier: 1.0
Total Install Cost=$163.76
E1.Ballast Disconnect 1.0 $0.70 0/$0.00
E2.SFL 5000°K Specification $0.00 0/$0.00
E3.Lamp T8 4'32W 2.0 $4.44 0/$0.00
E4.Reflector Troffer:2'x4'for 2L 1.0 $15.31 0.08/$6.00
E5.Ballast:T8-2L,IS,LBF 1.0 $14.95 0.33/$24.75
E6.Recycle:Non-PCB Ballast from 4'or Shorter 2.0 $0.00 0/$0.00
E7.Recycle:Fluorescent Lamps 4'or Shorter 4.0 $0.70 0/$0.00
E8.Ballast Disconnect 1.0 $0.70 0/$0.00
E9.SFL 5000°K Specification $0.00 0/$0.00
E10. Lamp T8 4'32W 2.0 $4.44 0/$0.00
E11.Reflector Troffer:2'x4'for 2L 1.0 $15.31 0.08/$6.00
E12.Ballast:T8-2L,IS,LBF 1.0 $14.95 0.33/$24.75
E13.Recycle:Non-PCB Ballast from 4'or Shorter 2.0 $0.00 0/$0.00
E14.Recycle:Fluorescent Lamps 4'or Shorter 4.0 $0.70 0/$0.00
Area: (9) Nursery 3
Area Comment:
T12 4' 40S 4L -PG&E/T8 4' 32W 2L LBF Dual Switch Step-Dim : [2346.3]-Hours=5.ox9.0
Access Difficulty: Ceiling Height: <9 ft
Control: Gang 2 Gan (8) (8) Annual Savings=$441.12/yr Standard g g
Page 7 Contractor Change Order 9/19/2014
Installation Comment: Rate Multiplier: 1.0 Rate Multiplier: 1.0
Total Install Cost=$805.12
E1.Reflector Troffer:2'x4'for 2L 8.0 $15.31 0.08/$6.00
E2.Recycle:Fluorescent Lamps 4'or Shorter 32.0 $0.70 0/$0.00
E3.Recycle:Non-PCB Ballast from 4'or Shorter 16.0 $0.00 0/$0.00
E4.Ballast Disconnect 16.0 $0.70 0/$0.00
E5.Lamp T8 4'32W 16.0 $4.44 0/$0.00
E6.Ballast Bi-Level 182 Lamp Quickstep LBF 8.0 $30.43 0.33/$24.75
E7.Control Wall Sensor Dual Switch 0.0 $79.40 0.5/$37.50
E8.Control:Gang 2 Gang Cover Plate 0.0 $5.00 0/$0.00
Area: (13) Room 9
Area Comment:
T12 4' 40S 3L -(PG&E)/T8 4' 32W 2L LBF Dual Switch Step-Dim : [2346.3]-Hours=5.0x9.0
5 5 Access Difficulty:
Control: Gang 2 G ( ) ( ) Annual Savings=$166.33/yr Standard Ceiling Height: <9 ft
Rate Multiplier: 1.0 Rate Multiplier: 1.0
Installation Comment: Total Install Cost=$499.55
E1.Ballast Disconnect 10.0 $0.70 0/$0.00
E2.Recycle:Fluorescent Lamps 4'or Shorter 15.0 $0.70 0/$0.00
E3.Lamp T8 4'32W 10.0 $4.44 0/$0.00
E4.Ballast Bi-Level 182 Lamp QuickStep LBF 5.0 $30.43 0.33/$24.75
E5.Control:Gang 2 Gang Cover Plate 0.0 $5.00 0/$0.00
E6.Recycle:Non-PCB Ballast from 4'or Shorter 10.0 $0.00 0/$0.00
E7.Reflector Troffer:2'x4'for 2L 5.0 $15.31 0.08/$6.00
E8.Control Wall Sensor Dual Switch 0.0 $79.40 0.5/$37.50
Page 8 Contractor Change Order 9/19/2014
Area: (14) Room 8
Area Comment:
T12 4' 40S 3L -(PG&E)/T8 4' 32W 2L LBF Dual Switch Step-Dim : [2346.3]-Hours=5.0x9.0
Control: Gang 2 G (5) (5) Annual Savings=$166.33/yr Access
Standard Difficulty:
Ceiling Height: <9 ft
RRate Multiplier: 1.0
Rate Multiplier: 1.0
Installation Comment: Total Install Cost=$499.55
E1.Ballast Disconnect 10.0 $0.70 0/$0.00
E2.Recycle:Fluorescent Lamps 4'or Shorter 15.0 $0.70 0/$0.00
E3.Lamp T8 4'32W 10.0 $4.44 0/$0.00
E4.Ballast Bi-Level 1&2 Lamp Quickstep LBF 5.0 $30.43 0.33/$24.75
E5.Control:Gang 2 Gang Cover Plate 0.0 $5.00 0/$0.00
E6.Recycle:Non-PCB Ballast from 4'or Shorter 10.0 $0.00 0/$0.00
E7.Reflector Troffer:2'x4'for 2L 5.0 $15.31 0.08/$6.00
E8.Control Wall Sensor Dual Switch 0.0 $79.40 0.5/$37.50
[260.7]-Hours=5.0x 1.0
T12-4'-34w-2L-MagES-RS-NL0/T8 4' 32w 2L LBF (1) (1) Access Difficulty: Ceiling Height: <9 ft
Annual Savings=$1.17/yr Standard Rate Multiplier: 1.0
Installation Comment:C0#1-bathroom Rate Multiplier: 1.0
Total Install Cost=$56.10
E1.Ballast:T8-2L,IS,LBF t0 $14.95 0.33/$24.75
E2.Ballast Disconnect 1.0 $0.70 0/$0.00
E3.Lamp T8 4'32W 2.0 $4.44 0/$0.00
E4.SFL 5000°K Specification $0.00 0/$0.00
E5.Recycle:Fluorescent Lamps 4'or Shorter 2.0 $0.70 0/$0.00
E6.Recycle:Non-PCB Ballast from 4'or Shorter 1.0 $0.00 0/$0.00
Area: (15) Room 7
Page 9 Contractor Change Order 9/19/2014
Area Comment:
T12 4' 40S 3L -(PG&E)/T8 4' 32W 2L LBF Dual Switch Step-Dim : [2346.3]-Hours=5.ox9.0
Control: Gan 2 G 5 5 Access Difficulty: g Height: <9 ft
Gang ( ) ( ) Annual Savings=$166.33/yr Standard Ceilin Hei
Rate Multiplier: 1.0 Rate Multiplier: 1.0
Installation Comment: Total Install Cost=$499.55
E1.Ballast Disconnect 10.0 $0.70 0/$0.00
E2.Recycle:Fluorescent Lamps 4'or Shorter 15.0 $0.70 0/$0.00
E3.Lamp T8 4'32W 10.0 $4.44 0/$0.00
E4.Ballast Bi-Level 1&2 Lamp QuickStep LBF 5.0 $30.43 0.33/$24.75
E5.Control:Gang 2 Gang Cover Plate 0.0 $5.00 0/$0.00
E6.Recycle:Non-PCB Ballast from 4'or Shorter 10.0 $0.00 0/$0.00
E7.Reflector Troffer:2'x4'for 2L 5.0 $15.31 0.08/$6.00
E8.Control Wall Sensor Dual Switch 0.0 $79.40 0.5/$37.50
T12-4'-34w-2L-MagES-RS-NLO/T8 4' 32W 2L NBF Continuous Dim [260.7]-Hours=5.0x1.0
1 1 Access Difficulty: Ceiling Height: <9 ft
( ) ( ) Annual Savings=$0.66/yr Standard
RRate Multiplier: 1-0
Rate Multiplier: 1.0
Installation Comment: Total Install Cost=$90.08
E1.Ballast Disconnect 1.0 $0.70 0/$0.00
E2.Lamp T8 4'32W 2.0 $4.44 0/$0.00
E3.Ballast Dimmable Quicktronic 2-lamp T8 NBF 1.0 $44.11 0.33/$24.75
E4.Recycle:Non-PCB Ballast from 4'or Shorter 1.0 $0.00 0/$0.00
E5.Recycle:Fluorescent Lamps 4'or Shorter 2.0 $0.70 0/$0.00
[52.14]-Hours=1.0x1.0
INC 60A/LED A-Lamp 11 W 2700K (60W equiv) (Philips) (3) (3) Access Difficulty: Ceiling Height: <9 ft
Annual Savings=$1.49/yr Standard Rate Multiplier. 1.0
Installation Comment: Rate Multiplier: 1.0
Total Install Cost=$79.92
Page 10 Contractor Change Order 9/19/2014
E1.LED A-Lamp 11 W 2700K(60W equiv)(Philips) 3.0 $17.49 0.08/$6.00
Area: (17) Office
Area Comment:
T12 4' 40S 4L -PG&E/T8 4' 32W 2L LBF Dual Switch Step-Dim : [2346.3]-Hours=5.0x9.0
Control: Gan 2 Gan 4 4 Access Difficulty: Ceiling Height: <9 ft
9 Annual Savings=$220.56/yr Standard
Rate Multiplier: 1.0 Rate Multiplier: 1.0
Installation Comment: Total Install Cost=$402.63
E1.Reflector Troffer:2'x4'for 2L 4.0 $15.31 0.08/$6,00
E2.Recycle:Fluorescent Lamps 4'or Shorter 16.0 $0.70 0/$0.00
E3.Recycle:Non-PCB Ballast from 4'or Shorter 8.0 $0.00 0/$0.00
E4.Ballast Disconnect 8.0 $0.70 0/$0.00
E5.Lamp T8 4'32W 8.0 $4.44 0/$0.00
E6.Ballast Bi-Level 1&2 Lamp Quickstep LBF 4.0 $30.43 0.33/$24.75
E7.Control Wall Sensor Dual Switch 0.0 $79.40 0.5/$37.50
E8.Control:Gang 2 Gang Cover Plate 0.0 $5.00 0/$0.00
Area: (18) Pastor Kim's Office
Area Comment:
T12 4' 40S 4L -PG&E/T8 4' 32W 2L LBF Dual Switch Step-Dim : [2346.3]-Hours=5.0x9.0
Access Difficulty:
Control: Gang 2 Gan (4 Ceiling Height: <9 ft
� �4� Annual Savings=$220.56/yr Standard
Rate Multiplier: 1.0 Rate Multiplier: 1.0
Installation Comment: Total Install Cost=$402.63
E1.Reflector Troffer:2'x4'for 2L 4.0 $15.31 0.08/$6.00
E2.Recycle:Fluorescent Lamps 4'or Shorter 16.0 $0.70 0/$0.00
E3.Recycle:Non-PCB Ballast from 4'or Shorter 8.0 $0.00 0/$0.00
E4.Ballast Disconnect 8.0 $0.70 0/$0.00
Page 11 Contractor Change Order 9/19/2014
E5.Lamp T8 4'32W 8.0 $4.44 0/$0.00
E6.Ballast Bi-Level 1&2 Lamp QuickStep LBF 4.0 $30.43 0.33/$24.75
E7.Control Wall Sensor Dual Switch 0.0 $79.40 0.5/$37.50
E8.Control:Gang 2 Gang Cover Plate 0.0 $5.00 0/$0.00
Area: (19) Copy Room
Area Comment:Area exempt from T24,less than 100 sq ft.
[52.14]-Hours=1.0x1.0
T12 4' 40S 4L -PG&E/T8 4' 32w 2L LBF w/Reflector(2) (2) Access Difficulty: Ceiling Height: <9 ft
Annual Savings=$2.41 /yr Standard
Installation Comment: Rate Multiplier: 1.0 Rate Multiplier: 1.0
Total Install Cost=$327.65
E1.Ballast Disconnect 2.0 $0.70 0/$0.00
E2.SFL 5000°K Specification $0.00 0/$0.00
E3.Lamp T8 4'32W 4.0 $4.44 0/$0.00
E4.Reflector-Troffer:2'x4'for 2L 2.0 $15.31 0.08/$6.00
E5.Ballast:T8-2L,IS,LBF 2.0 $14.95 0.33/$24.75
E6.Recycle:Non PCB Ballast from 4'or Shorter 4.0 $0.00 0/$0.00
E7.Recycle:Fluorescent Lamps 4'or Shorter 8.0 $0.70 0/$0.00
E8.Ballast Disconnect 2.0 $0.70 0/$0.00
E9.SFL 5000°K Specification $0.00 0/$0.00
E10.Lamp T8 4'32W 4.0 $4.44 0/$0.00
E11. Reflector Troffer:2'x4'for 2L 2.0 $15.31 0.08/$6.00
E12. Ballast:T8-2L,IS,LBF 2.0 $14.95 0.33/$24.75
E13. Recycle:Non-PCB Ballast from 4'or Shorter 4.0 $0.00 0/$0.00
E14.Recycle:Fluorescent Lamps 4'or Shorter 8.0 $0.70 0/$0.00
Page 12 Contractor Change Order 9/19/2014
Area: (20) Finance Room
Area Comment:
T12 4' 40S 4L -PG&E/T8 4' 32W 2L LBF Dual Switch Step-Dim : [2346.3]-Hours=5.0x9.0
Access Difficulty: Ceiling Height: <9 ft
Control: Gang 2 Gan (2) (2) Annual Savings=$110.28/yr Standard g g
Rate Multiplier: 1.0 Rate Multiplier. 1.0
Installation Comment: Total Install Cost=$201.24
E1.Reflector Troffer:2'x4'for 2L 2.0 $15.31 0.08/$6.00
E2.Recycle:Fluorescent Lamps 4'or Shorter 8.0 $0.70 0/$0.00
E3.Recycle:Non-PCB Ballast from 4'or Shorter 4.0 $0.00 o/$0.00
E4.Ballast Disconnect 4.0 $0.70 0/$0.00
E5.Lamp T8 4'32W 4.0 $4.44 o/$0.00
E6.Ballast Bi-Level 182 Lamp QuickStep LBF 2.0 $30.43 0.33/$24.75
E7.Control Wall Sensor Dual Switch 0.0 $79.40 0.5/$37.50
E8.Control:Gang 2 Gang Cover Plate 0.0 $5.00 0/$0.00
Area: (21) Office Manager
Area Comment:
T12 4' 40S 4L -PG&E/T8 4' 32W 2L LBF Dual Switch Step-Dim : [2346.3]-Hours=5.ox9.0
Access Difficulty Ceiling Height: <9 ft
Control: Gang 2 Gan (2) (2) Annual Savings=$110.28/yr Standard g g
Rate Multiplier: 1.0 Rate Multiplier: 1.0
Installation Comment: Total Install Cost=$201.24
E1.Reflector Troffer:2'x4'for 2L 2.0 $15.31 0.08/$6.00
E2.Recycle:Fluorescent Lamps 4'or Shorter 8.0 $0.70 0/$0.00
E3.Recycle:Non-PCB Ballast from 4'or Shorter 4.0 $0.00 0/$0.00
E4.Ballast Disconnect 4.0 $0.70 0/$0.00
E5.Lamp T8 4'32W 4.0 $4.44 0/$0.00
Page 13 Contractor Change Order 9/19/2014
E6.Ballast Bi-Level 182 Lamp QuickStep LBF 2.0 $30.43 0.33/$24.75
ET Control Wall Sensor Dual Switch 0.0 $79.40 0.5/$37.50
E8.Control:Gang 2 Gang Cover Plate 0.0 $5.00 0/$0.00
Area: (22) Matt Hall's Office
Area Comment:
T12 4' 40S 4L -PG&E/T8 4' 32W 2L LBF Dual Switch Step-Dim : [2346.3]-Hours=5.0x9.0
Control: Gan 2 2 2 Access Difficulty: Ceiling Height: <9 ft
Gang Gan ( ) ( ) Annual Savings=$110.28/yr Standard
RRate Multiplier: 1.0
Rate Multiplier: 1.0
Installation Comment: Total Install Cost=$201.24
E1.Reflector-Troffer:2'x4'for 2L 2.0 $15.31 0.08/$6.00
E2.Recycle:Fluorescent Lamps 4'or Shorter 8.0 $0.70 0/$0.00
E3.Recycle:Non-PCB Ballast from 4'or Shorter 4.0 $0.00 0/$0.00
E4.Ballast Disconnect 4.0 $0.70 0/$0.00
E5.Lamp T8 4'32W 4.0 $4.44 0/$0.00
E6.Ballast Bi-Level 182 Lamp QuickStep LBF 2.0 $30.43 0.33/$24.75
ET Control Wall Sensor Dual Switch 0.0 $79.40 0.5/$37.50
E8.Control:Gang 2 Gang Cover Plate 0.0 $5.00 0/$0.00
Area: (23) Sarah's Office
Area Comment:
T12 4' 40S 4L -PG&E/T8 4' 32W 2L LBF Dual Switch Step-Dim : [2346.3]-Hours=5.0x9.0
Access Difficulty: Ceiling Height: <9 ft
Control: Gang 2 Gan (2) (2) Annual Savings=$110.28/yr Standard g g
Rate Multiplier: 1.0 Rate Multiplier: 1.0
Installation Comment: Total Install Cost=$201.24
E1.Reflector Troffer:2'x4'for 2L 2.0 $15.31 0.08/$6.00
E2.Recycle:Fluorescent Lamps 4'or Shorter 8.0 $0.70 0/$0.00
Page 14 Contractor Change Order 9/19/2014
E3.Recycle:Non-PCB Ballast from 4'or Shorter 4.0 $0.00 0/$0 00
E4.Ballast Disconnect 4.0 $0.70 0/$0.00
E5.Lamp T8 4'32W 4.0 $4.44 0/$0.00
E6.Ballast Bi-Level 1&2 Lamp Quickstep LBF 2.0 $30.43 0.33/$24.75
E7.Control Wall Sensor Dual Switch 0.0 $79.40 0.5/$37.50
E8.Control:Gang 2 Gang Cover Plate 0.0 $5.00 0/$0.00
Area: (24) Sunday School Superintendent Office
Area Comment:
T12 4' 40S 4L -PG&E/T8 4' 32W 2L LBF Dual Switch Step-Dim : [2346.3]-Hours=5.0x9.0
2 Gan 2 2 Access Difficulty, Ceiling Height: <9 ft
Control: Gang ( ) ( ) Annual Savings=$110.28/yr Standard Rate Multiplier: 1.0
Rate Multiplier: 1.0
Installation Comment: Total Install Cost=$201.24
E1.Reflector Troffer:2'x4'for 2L 2.0 $15.31 0.08/$6.00
E2.Recycle:Fluorescent Lamps 4'or Shorter 8.0 $0.70 0/$0.00
E3.Recycle:Non-PCB Ballast from 4'or Shorter 4.0 $0.00 0/$0.00
E4.Ballast Disconnect 4.0 $0.70 0/$0.00
E5.Lamp T8 4'32W 4.0 $4.44 0/$0.00
E6.Ballast Bi-Level 1&2 Lamp Quickstep LBF 2.0 $30.43 0.33/$24.75
E7.Control Wall Sensor Dual Switch 0.0 $79.40 0.5/$37.50
E8.Control:Gang 2 Gang Cover Plate 0.0 $5.00 0/$0.00
Area: (25) Mail Area
Area Comment:Area Exempt from T24 less than 100 sq.ft
[52.14]-Hours=1.0x 1.0
T12 4' 40S 4L -PG&E/T8 4' 32w 2L LBF w/Reflector(2) (2) Access Difficulty:
Page 15 Contractor Change Order 9/19/2014
Annual Savings=$2.41 /yr Standard Ceiling Height: <9 ft
Installation Comment: Rate Multiplier: 1.0 Rate Multiplier: 1.0
Total Install Cost=$327.65
E1.Ballast Disconnect 2.0 $0.70 0/$0.00
E2.SFL 5000°K Specification $0.00 0/$0.00
E3.Lamp T8 4'32W 4.0 $4.44 0/$0.00
E4.Reflector Troffer:2'x4'for 2L 2.0 $15.31 0.08/$6.00
E5.Ballast:T8-2L,IS,LBF 2.0 $14.95 0.33/$24.75
E6.Recycle:Non-PCB Ballast from 4'or Shorter 4.0 $0.00 0/$0.00
I
E7.Recycle:Fluorescent Lamps 4'or Shorter 8.0 $0.70 0/$0.00
E8.Ballast Disconnect 2.0 $0.70 0/$0.00
E9.SFL 5000°K Specification $0.00 0/$0.00
E10.Lamp T8 4'32W 4.0 $4.44 0/$0.00
E11.Reflector Troffer:2'x4'for 2L 2.0 $15.31 0.08/$6.00
E12.Ballast:T8-2L,IS,LBF 2.0 $14.95 0.33/$24.75
E13. Recycle:Non-PCB Ballast from 4'or Shorter 4.0 $0.00 0/$0.00
E14.Recycle.Fluorescent Lamps 4'or Shorter 8.0 $0.70 0/$0.00
Area: (26) Worship Director's Office
Area Comment:
T12 4' 40S 4L -PG&E/T8 4' 32W 2L LBF Dual Switch Step-Dim : [2346.3[-Hours=5.ox9.0
Control: Gan 2 Gan 4 4 Access Difficulty: Ceiling Height: <9 ft
9 Annual Savings=$220.56/yr Standard R
Rate Multiplier: 1.0 ate Multiplier: 1.0
Installation Comment: Total Install Cost=$402.63
E1.Reflector Troffer:2'x4'for 2L 4.0 $15.31 0.08/$6.00
E2.Recycle:Fluorescent Lamps 4'or Shorter 16.0 $0.70 0/$0.00
Page 16 Contractor Change Order 9/19/2014
E3.Recycle:Non-PCB Ballast from 4'or Shorter 8.0 $0.00 0/$0.00
E4.Ballast Disconnect 8.0 $0.70 0/$0.00
E5.Lamp T8 4'32W 8.0 $4.44 0/$0.00
E6.Ballast Bi-Level 1&2 Lamp QuickStep LBF 4.0 $30.43 0.33/$24.75
E7.Control Wall Sensor Dual Switch 0.0 $79.40 0.5/$37.50
E8.Control:Gang 2 Gang Cover Plate 0.0 $5.00 0/$0.00
Area: (27) Fridlund Kitchen
Area Comment:
T12 4' 40S 4L -PG&E/T8 4' 32W 2L LBF Dual Switch Step-Dim : [521.4]-Hours=5.0x2.0
2 Gan 2 2 Access Difficulty: Ceiling Height: < 9 ft
Control: Gang ( ) ( ) Annual Savings=$24.51 /yr Standard Rate Multiplier: 1.0
Rate Multiplier: 1.0
Installation Comment: Total Install Cost=$201.24
E1.Reflector Troffer:2'x4'for 2L 2.0 $15.31 0.08/$6.00
E2.Recycle:Fluorescent Lamps 4'or Shorter 8.0 $0.70 0/$0.00
E3.Recycle:Non-PCB Ballast from 4'or Shorter 4.0 $0.00 0/$0.00
E4.Ballast Disconnect 4.0 $0.70 0/$0.00
E5.Lamp T8 4'32W 4.0 $4.44 0/$0.00
E6. Ballast Bi-Level 1&2 Lamp QuickStep LBF 2.0 $30.43 0.33/$24.75
E7.Control Wall Sensor Dual Switch 0.0 $79.40 0.5/$37.50
E8.Control:Gang 2 Gang Cover Plate 0.0 $5.00 o/$0.00
Area: (28) Room 11
Area Comment:
T12 4' 40S 4L -PG&E/T8 4' 32W 2L LBF Dual Switch Step-Dim : [2346.3]-Hours=5.0x9.0
Access Difficulty: Ceiling Height: <9 ft
Control: Gang 2 Gan (8) (8) Annual Savings=$441.12/yr Standard g g
Page 17 Contractor Change Order 9/19/2014
Installation Comment: Rate Multiplier: 1.0 Rate Multiplier: 1.0
Total Install Cost=$805.12
E1.Reflector-Troffer:2'x4'for 211 8.0 $15.31 0.08/$6.00
E2.Recycle:Fluorescent Lamps 4'or Shorter 32.0 $0.70 0/$0.00
E3.Recycle:Non-PCB Ballast from 4'or Shorter 16.0 $0.00 0/$0.00
E4.Ballast Disconnect 16.0 $0.70 0/$0.00
E5.Lamp T8 4'32W 16.0 $4.44 0/$0.00
E6.Ballast Bi-Level 182 Lamp QuickStep LBF 8.0 $30.43 0.33/$24.75
E7.Control Wall Sensor Dual Switch 0.0 $79.40 0.5/$37.50
E8.Control:Gang 2 Gang Cover Plate 0.0 $5.00 0/$0.00
Area: (29) Room 12
Area Comment:
T12 4' 40S 4L -PG&E/T8 4' 32W 2L LBF Dual Switch Step-Dim : [2346.3]-Hours=5.0x9.0
Control: Gan Gan Access Difficulty: Ceiling Height: <9 ft
9 2 8) 8) Annual Savings=$441.12/yr Standard
Rate Multiplier 1.0
Rate Multiplier: 1.0
Installation Comment: Total Install Cost=$805.12
E1.Reflector Troffer:2'x4'for 2L 8.0 $15.31 0.08/$6.00
E2.Recycle:Fluorescent Lamps 4'or Shorter 32.0 $0.70 0/$0.00
E3.Recycle:Non-PCB Ballast from 4'or Shorter 16.0 $0.00 0/$0.00
E4.Ballast Disconnect 16.0 $0.70 0/$0.00
E5.Lamp T8 4'32W 16.0 $4.44 0/$0.00
E6. Ballast Bi-Level 182 Lamp QuickStep LBF 8.0 $30.43 0.33/$24.75
E7.Control Wall Sensor Dual Switch 0.0 $79.40 0.5/$37.50
E8.Control:Gang 2 Gang Cover Plate 0.0 $5.00 0/$0.00
Page 18 Contractor Change Order 9/19/2014
Area: (30) Room 13
Area Comment:
T12 4' 40S 4L -PG&E/T8 4' 32W 2L LBF Dual Switch Step-Dim : [2346.3]-Hours=5.0x9.0
Control: Gang 2 Gan (8) (8) Access Difficulty: Ceiling Height: <9 ft
Annual Savings=$441.12/yr Standard
Rate Multiplier: 1.0 Rate Multiplier: 1.0
Installation Comment: Total Install Cost=$805.12
E1.Reflector Troffer:2'x4'for 2L 8.0 $15.31 0.08/$6.00
E2.Recycle:Fluorescent Lamps 4'or Shorter 32.0 $0.70 0/$0.00
E3.Recycle:Non-PCB Ballast from 4'or Shorter 16.0 $0.00 0/$0.00
E4.Ballast Disconnect 16.0 $0.70 0/$0.00
E5.Lamp T8 4'32W 16.0 $4.44 0/$0.00
E6.Ballast Bi-Level 182 Lamp QuickStep LBF 8.0 $30.43 0.33/$24.75
E7. Control Wall Sensor Dual Switch 0.0 $79.40 0.5/$37.50
E8.Control:Gang 2 Gang Cover Plate 0.0 $5.00 0/$0.00
Area: (31) Room 14
Area Comment:
T12 4' 40S 4L -PG&E/T8 4' 32W 2L LBF Dual Switch Step-Dim : [2346.3]-Hours=5.0x9.0
2 Gan 8 8 Access Difficulty: Ceiling Height: <9 ft
Control: Gang ( ) ( ) Annual Savings=$441.12/yr Standard Rate Multiplier: 1.0
Rate Multiplier: 1.0
Installation Comment: Total Install Cost=$805.12
E1.Reflector Troffer:2'x4'for 2L 8.0 $15.31 0.08/$6.00
E2.Recycle:Fluorescent Lamps 4'or Shorter 32.0 $0.70 0/$0.00
E3.Recycle:Non-PCB Ballast from 4'or Shorter 16.0 $0.00 0/$0.00
E4.Ballast Disconnect 16.0 $0.70 0/$0.00
FEEm�pp:T:8:4'32W 16.0 $4.44 0/$0 00
Page 19 Contractor Change Order 9/19/2014
E6.Ballast Bi-Level 1&2 Lamp QuickStep LBF 8.0 $30.43 0.33/$24.75
E7.Control Wall Sensor Dual Switch 0.0 $79.40 0.5/$37.50
E8.Control:Gang 2 Gang Cover Plate 0.0 $5.00 0/$0.00
Area: (32) Room 15
Area Comment:
T12 4' 40S 4L -PG&E/T8 4' 32W 2L LBF Dual Switch Step-Dim : [2346.3]-Hours=5.0x9.0
Access Difficulty: Hei t: <
Control: Gang 2 Gan (16) (16) Annual Savings=$882.23/yr Standard Ceiling9 ft
Rate Heigtiht: 1.0
Rate Multiplier: 1.0
Installation Comment: Total Install Cost=$1,610.25
F1.Reflector-Troffer:2'x4'for 2L 16.0 $15.31 0.08/$6.00
E2.Recycle:Fluorescent Lamps 4'or Shorter 64.0 $0.70 0/$0.00
E3.Recycle:Non-PCB Ballast from 4'or Shorter 32.0 $0.00 0/$0.00
E4.Ballast Disconnect 32.0 $0.70 0/$0.00
F5.Lamp T8 4'32W 32.0 $4.44 0/$0.00
E6.Ballast Bi-Level 1&2 Lamp QuickStep LBF 16.0 $30.43 0.33/$24.75
E7.Control Wall Sensor Dual Switch 0.0 $79.40 0.5/$37.50
E8.Control:Gang 2 Gang Cover Plate 0.0 $5.00 0/$0.00
Area: (34) Exterior Storage Room
Area Comment:Rooms with 1 fixture each,exempt from T24
[52.14]-Hours=1.0x1.0
T12 4' 40S 4L -PG&E/T8 4' 32w 2L LBF w/Reflector (2) (2) Access Difficulty: Ceiling Height: <9 ft
Annual Savings=$2.41/yr Standard Rate Multiplier: 1.0
Installation Comment: Rate Multiplier: 1.0
Total Install Cost=$327.65
E1.Ballast Disconnect 2.0 $0.70 0/$0.00
E2.SFL 5000°K Specification $0.00 0/$0.00
Page 20 Contractor Change Order 9/19/2014
E3.Lamp T8 4'32W 4.0 $4.44 0/$0.00
E4.Reflector_Troffer:2'x4'for 2L 2.0 $15.31 0.08/$6.00
E5.Ballast:T8-2L,IS,LBF 2.0 $14.95 0.33/$24.75
E6.Recycle:Non-PCB Ballast from 4'or Shorter 4.0 $0.00 0/$0.00
E7.Recycle:Fluorescent Lamps 4'or Shorter 8.0 $0.70 0/$0.00
E8.Ballast Disconnect 2.0 $0.70 0/$0.00
E9.SFL 5000°K Specification $0.00 0/$0.00
E10.Lamp T8 4'32W 4.0 $4.44 0/$0.00
E11.Reflector Troffer:2'x4'for 2L 2.0 $15.31 0.08/$6.00
E12.Ballast:T8-2L,IS,LBF 2.0 $14.95 0.33/$24.75
E13.Recycle.Non-PCB Ballast from 4'or Shorter 4.0 $0.00 0/$0.00
E14.Recycle:Fluorescent Lamps 4'or Shorter 8.0 $0.70 0/$0.00
[52.14]-Hours=1.0x 1.0
T12-4'-34w-2L-EI-RS-NL0/T8 4' 32W 2L LBF (1) (1) Access Difficulty: Ceiling Height: <9 ft
Annual Savings=$o.11 /yr Standard Rate Multiplier: 1.0
Installation Comment: Rate Multiplier: 1.0
Total Install Cost=$56.35
E1.Recycle.Fluorescent Lamps 4'or Shorter 2.0 $0.70 0/$0.00
E2.SFL 5000°K Specification $0.00 0/$0.00
E3.Lamp T8 4'32W 2.0 $4.44 0/$0.00
E4.Ballast Disconnect 1.0 $0.70 0/$0.00
E5.Ballast:T8-2L, IS,LBF 1.0 $14.95 0.33/$24.75
E6.Recycle:Non-PCB Ballast from 4'or Shorter 1.0 $0.00 0/$0.00
Area: (194422) Custodian room
Area Comment:
Page 21 Contractor Change Order 9/19/2014
[11 560.0]-Ho u rs=5.0x6.0
T12-4'-34w-2L-MagES-RS-NLO/T8 4' 32w 2L LBF (1) (1) Access Difficulty: Ceiling Height: <9 ft
Annual Savings=$7.00/yr Standard Rate Multiplier: 1.0
Installation Comment:C0#1 Rate Multiplier: 1.0
Total Install Cost=$56.35
E1.Ballast:T8-2L,IS,LBF 1.0 $14.95 0.33/$24.75
E2.Ballast Disconnect 1.0 $0.70 0/$0.00
E3.Lamp T8 4'32W 2.0 $4.44 0/$0.00
E4.SFL 5000°K Specification $0.00 0/$0.00
E5.Recycle:Fluorescent Lamps 4'or Shorter 2.0 $0.70 0/$0.00
E6.Recycle:Non-PCB Ballast from 4'or Shorter 1.0 $0.00 0/$0.00
Page 22 Contractor Change Order 9/19/2014
• The Silicon Valley Energy Watch Program is implemented th Silicon Valley Energy Watch
Ecology Action and funded by California ratepayers under the _, ..
auspices of the California Public Utility Commission. Energy Efficiency Program
Change Order#: Recommendations and Savings Checklist
2 West Valley Presbyterian Church - MLTG (CO#2)
Materials List Summary
West Valley Presbyterian Church
6191 Bollinger Rd.
Cupertino,CA 95014
Equipment Labor Custom
Equipment Quantity Cost(Per Hrs/Cost(Per
IPriced Item
Item) Item)
Ballast: T8-2L, IS, LBF- Sylvania-49200 18.0 $14.95 0.33/$24.75 ❑
LED PAR38 19W 36DEG 3000K(90W equiv) (Philips)- Philips-429126 60.0 $36.06 0.08/$6.00 ❑
LED PAR30 Short Neck 12W 36DEG 3000K(Philips)- Philips-426964 20.0 $36.44 0.08/$6.00 ❑
Control Wall Sensor Dual Switch-WattStopper- PW-200 26.0 $79.40 0.5/$37.50
LED A-Lamp 11 W 2700K (60W equiv) (Philips)- Philips-423491 17.0 $17.49 0.08/$6.00 ❑
Custom Component 2-Bulb Extenders(if necessary) 50.0 $3.00 0/$0.00
Ballast Disconnect-Wago- 873-902 258.0 $0.70 0/$0.00 ❑
Lamp T8 4' 32W(SFL 5000°K)- Philips- 13987-0 or 13988-1 or 139 36.0 $4.44 0/$0.00 ❑
Control Wall Sensor-WattStopper- PW-100 1.0 $69.44 0.5/$37.50
Ballast Bi-Level 1&2 Lamp QuickStep LBF-Sylvania -49158 119.0 $30.43 0.33/$24.75 ❑
Page 23 Contractor Change Order 9/19/2014
Lamp T8 4' 32W- Philips- 13987-0 or 13988-1 or 139 242.0
$4.44 o/$o.00 ❑
Reflector Troffer: 2'x4'for 2L-Wellmade Reflectors- R304-248T8 133.0 $15.31 0.08/$6.00 p
Control: Gang 2 Gang Cover Plate 27.0 $5.00 0/$0.00 9
Custom Component 1-Bulb Extenders 30.0 $3.00 0/$0.00 p
Ballast Dimmable Quicktronic 2-lamp T8 NBF- Sylvania- 50707 2.0 $44.11 0.33/$24.75 ❑
Recycle: Fluorescent Lamps 4'or Shorter 523.0 $0.70 0/$0.00 ❑
Recycle: Non-PCB Ballast from 4' or Shorter 273.0 $0.00 0/$0.00 ❑
Disposal $366.10
Material $13,128.27
Base Labor Cost $5,832.75
Access Difficulty Cost Adjustment $0.00
Ceiling Height Cost Adjustment $219.60
Labor(weekdays Rate) $6,052.35
Pre-inspection Fee $90.00
Notes and Comments Permit Processing Fee $150.00
Permit Fee $666.39
Weekly Scissors Lift:$425/Week Fee $425.00
Estimated Taxes $1,148.69
$22,047.49
Total (Including
special
orders)
Page 24 Contractor Change Order 9/19/2014
The Silicon Valley Energy Watch Program is implemented Silicon Valley Energy Watch
Ecology Action and funded by California ratepayers under the ,
auspices of the California Public Utility Commission. Energy Efficiency Program
`
Change Order M Customer Change Order Agreement
2 West Valley Presbyterian Church - MLTG (CO#2)
West Valley Presbyterian Church
6191 Bollinger Rd.
Cupertino,CA 95014
Contractor:
_YES,ABI Services, Inc does accept the project.[West Valley Presbyterian Church-MLTG(CO#2)]
The cost of the work included in this bid proposal is not to exceed$22047.49 unless a fully executed and approved change order is received by the RightLights Program Administrator.The price and
specifications of this bid proposal are satisfactory and are hereby accepted by ABI Services, Inc.All work will be completed within three weeks of the project start date shown below.All work will be
completed pursuant to the terms of conditions specified in the original Contractor Participation Agreement between Ecology Action and ABI Services, Inc.
Per the RightLights Installation Standards the undersigned contractor will submit a fully-detailed invoice,a manifest for any associated recycling fees,and a Project Completion and Customer
Acceptance Certificate signed by the Customer.Upon receipt of these documents and a successful post-installation inspection,Ecology Action will pay the contractor the rebate portion of installed
costs. It is incumbent on the contractor to collect the remaining portion of installed costs from the customer.
Scheduled start date:
_NO,ABI Services, Inc does not accept the project.
The undersigned understands that repeated project refusals will result in exclusion from the RightLights Program. If desired,please comment on why the project was refused.
I certify that I am a licensed contractor and will comply with applicable permitting requirements,as appropriate,for this HVAC or lighting installation or replacement.
License#
Authorized Signature (Contractor) Date
(print name) Company
Customer:
The above prices and specifications of this Change Order are satisfactory and are hereby accepted.All work to be performed under same terms and conditions as specified in the original contract
unless otherwise stipulated.Customer Cost: 1377.48
Authorized Signature (Customer) Date
(print name) Company
Page 25 Contractor Change Order 9/19/2014
Page 26 Contractor Change Order 9/19/2014
L I +.'.,I.F
PROJECT COMPLETION AND CUSTOMER ACCEPTANCE CERTIFICATE
Contractor Statement
ABI Services, Inc(firm name) certifies that we installed the following:
In the building of:
Business Name: West Valley Presbyterian Church- MLTG (CO#2)
Street Address:6191 Bollinger Rd. City:Cupertino State:CA Zip:95014
Contractor Name : ABI Services, Inc Date:
Authorized Signature: Title:
Print Name:
Customer Statement
The undersigned hereby certifies that all equipment and materials included in the retrofit project including any change orders have been furnished and installed,
and that the work has been completed satisfactorily.
I understand that the Contractor is not an employee or representative of Ecology Action. 1 understand and agree that Ecology Action is not in any way liable or
responsible for any acts or omissions of Contractor.
By the signature below I certify that I have not accepted any incentives (i.e., rebates offered by Pacific Gas and Electric or any other energy-efficiency program
towards work that is covered by this agreement)from a source other than Ecology Action.
Date :
NOTICE TO CUSTOMER : Business Name : West Valley Presbyterian Church - MLTG (CO#2)
DO NOT SIGN this certificate until you Authorized Signature
are completely satisfied that the
Contractor has fulfilled his obligation to (print name):
you and the work or equipment has Title
been satisfactorily completed.
(Read before signing)
Page 27 Contractor Change Order 9/19/2014
Silicon Valley Energy Watch Customer Testimonial/information Release Form
Permission to Use Customer Energy Retrofit Information and/or Testimonial
In an effort to recognize the energy-savings accomplishments of its participants and promote the wider adoption of energy efficiency,
the Silicon Valley Energy Watch Program requests that satisfied customers provide permission to use information from their projects
for marketing and educational purposes.Your confidential information will never be sold to third party marketing firms.
Please initial below the extent to which you authorize promotional use of information related to your energy-efficiency project.
Promotional materials may be published and distributed in printed form, on the Internet and/or other formats,via text, pictures and/or
video formats.
Please initial each item as appropriate.
You may publish my energy savings information,measures installed,type of business,and the community in
which my business is located.
You may identify my business by name and address.
You may identify me by name and publish a statement attributable to me.
I DO NOT authorize the promotional uses of my information described above.
Customer:
Authorized Signature:
West Valley Presbyterian Church Print Name:
6191 Bollinger Rd.
Cupertino,CA 95014 Title:
Date:
Page 28 Contractor Change Order 9/19/2014