Loading...
13090066CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 825 KIM ST CONTRACTOR: NEW WORLD BUILDER PERMIT NO: 13090066 OWNER'S NAME: HEMAMALINI SANKAR 1 196 BRANDYBOOD WAY DATE ISSUED: 06/09/2014 OWNER'S PHONE: 4084167410 SAN JOSE, CA 95121 PHONE NO: (408) 472-3692 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL E] COMMERCIAL 5 ADDITION OF 537 S.F. TO FRONT OF SFD, REMODEL (E) License Class Lic. #' e7 O KITCHEN & CREATE (N) DINING RM AREA. RE -ROOF (E) V 6 (� 20 SQ'S TO MATCH ADDITION Contractor t -)Date r?-Zv I hereby of in that 1 am licensed under the provisions of Chapter 9 1 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $122000 performance of the work for which this permit is issued. 1 have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 35920004.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION 1 certify that 1 have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF ISSUANCE OR to building construction, and hereby authorize representatives of this city to enterupon �Ml' the above mentioned property for inspection purposes. (We) agree to save CLLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgmen costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply I Y.Date: v with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature dn%L Date C— 7, 1 RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ElV OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 25505, 25533, and 25534. Section 3700 of the Labor Code, for the performance of the work for which this ' / p IiV J Date: permit is issued. Owner or authorized agent: C7 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, 1 CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, ARCHITECT'S DECLARATION costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date CUPERTINO CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION O0� 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 41 (408) 777-3228 • FAX (408) 777-3333 • building a-cupertino.org ❑ NEW CONSTRUCTION © ADDITION ❑ ALTERATION / TI ❑ REVISION / DEFERRED ORIGINAL PERMIT # PROJECT ADDRESS 825 KIM STREET 7 APN# 359-20-004 OWNER NAME HEMAMALINI SANKAR PHONE (408)416-7410 E-MAIL 171.LI11 —It STREET ADDRESS 825 KIM STREET CITY, STATE, ZIP CUPERTINO, CA FAX N/A CONTACT NAME Juancarlos Navarro PHONE (408)205-9812 —7 E-MAIL jcnavarro@att.net STREET ADDRESS 1734 Winston St CITY, STATE, Z1PSan Jose, CA 95131 FAX (408)459-1619 ❑ OWNER ❑ OWNER -BUILDER 11 OWNER AGENT 11 CONTRACTOR 11 CONTRACTOR AGENT W ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME TBD D LICENSE NUMBER LICENSE TYPE BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE ARCHITECT/ENGINEER NAME Jose C. Fernadez LICENSE NUMBER C76349 BUS. LIC # COMPANY NAME IF Consultingplans@gmail.com E-MAIL FAX N/A STREET ADDRESS 2915 Maclntyre Dr# 104 CITY, STATE, ZIP San Jose, CA 95136 PHONE(408)512-8400 DESCRIPTION OF WORK Interior remodel, addition. Remodel e) kitchen, add 537 s.f. to the front of the house to add a new bedroom, one bathroom, and new living area, convert one bedroom into dining room and re -roof entire house. (Bldg, Plumbing, Electrical and mechanical permits) EXISTING USE single fam PROPOSED USE CONSTR. No chane TYPE v # STORIES 1 USE TYPE OCC. SQ.FT. VALUATION ($) AREAEXIST AREA 1, 603 NEW 1, 140 AREA DEMO 165 Porc TOTAL AREA NET AREA 2140 kitchen re odel $25 k BATHROOM REMODEL AREA KITCHEN REMODEL AREA ZZZ OTHER REMODEL AREA 2K too Addition 537 $97 k PORCH AREA 33 DECK AREA 0 TOTAL DECK/PORCH AREA 33 GARAGE AREA: DETACH 482 IM ATTACH # DW'ELLING UNITS. IS A SECOND UNIT ❑ YES SECOND STORY ❑ YES 1 BEING ADDED? M NO ADDITION? R) NO PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF IS THE BLDG AN ❑ YES RECEIy TAL VALUATION - PLANNING APPL # M NO PLANNING APPROVAL LETTER EICHLER HOME? M NO $122 k owner or thorized a o ac a property owner's behalf. I have read this By my signature below, 1 certify to each of the following: 1 am the plepresen application and the information I have provided is correct. 1 have reaescripti of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. 1 authoriz s of Cupertino to enter the above -identified property for inspection purposes. Signature of Applicant/Agent: Juancarlos Navarro Date: September 11, 2013 SUPPLEMENTAL INFORM TIO E IRED PLAN CHECK TYPE ROUTING SLIP 0 OV R.TM-COUNTER E3 BUILDING PLAN REVIEW New SFD or Multifamily dwellings: Apply fo d olition pe it for existing building(s). Demolition permit is required prior to issu ce of building permit for new building. ❑ EXPRESS ❑ PLANNING PLAN REVIEW Commercial Bldgs: Provide a completed Hazardous Materials Disclosure C$ STANDARD PUBLIC WORKS form if any Hazardous Materials are being used as part of this project. 0 LARGE 13 FIRE DEPT Copy of Planning Approval Letter or Meeting with Planning prior to 0 MAJOR © SANITARY SEWER DISTRICT submittal of Building Permit application. © ENVIRONMENTAL HEALTH BldgApp 2011.doc revised 06/21/11 CITY OF CUPERTINO FEE ESTIMATOR - BUILDING DIVISION OCCUPANCY TYPE: 825 KIM ST DATE: 09/11/2013 REVIEWED BY: MELISSA 1WADDRESS: APN: 359 20 004 BP#: ��9 GQ 'VALUATION: 1$122,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY SFD or Duplex USE: 2nd Unit? Yes . No OTC: O Yes (E) No I PENTAMATION 1 R3SFDADD PERMIT TYPE: WORK ADDITION OF 537 S.F. TO FRONT OF SFD REMODEL E KITCHEN & CREATE N DINING RM. SCOPE RE -ROOF (E) 20 SQ'S TO MATCH ADDITION OCCUPANCY TYPE: TYPE OF CONSTR. FLR AREA s.f. PC FEES PC FEE ID BP FEES BP FEE ID R-3 (Custom) II-B'111-B,IV,V-B 537 $2,577.00 IR3PLNCK $1,617.00 IR3INSP PME Plan Check: $0.00 100 s.f. $418.00 Remodel, Other IREMRESOTH Permit Fee: $1,617.00 Suppl. Insp. Fee -0 Reg. O OT 0,0 hrs $0.00 2,000 s.f. Re -roof $320.00 IREROOFRES PME Unit Fee: $0.00 PME Permit Fee: $0.00 P. [Itl:ift"dti'(it)f? lt:.i: TOTALS: 537 $2,577.00 $1,617.00 MECH, HOURLY O Yes Q No PLUMB, HOURLY O Yes O ' No ELEC, HOURLY -()Yes O No MISC ITEMS Plan Check Fee: $2,577.00 222 1 s.£ $626.00 Remodel, Kitchen (<=300 sf) IREMRESKIT c' �l. Tr:. A`•�� hrs $0.00 PME Plan Check: NOTE: This estimate does not include fees due to other Departments (i. e. Planning, Public Works, Fire, Sanitary Sewer District, School District etc ). These fees are haled an the nreliminary information available and are only an estimate. Contact the Dent for addn'1 info. FEE ITEMS (Fee Resolution 11-053 Eff 711113) FEE QTY/FEE MISC ITEMS Plan Check Fee: $2,577.00 222 1 s.£ $626.00 Remodel, Kitchen (<=300 sf) IREMRESKIT Suppl. PC Fee: Q Reg. O OTT0.0 hrs $0.00 PME Plan Check: $0.00 100 s.f. $418.00 Remodel, Other IREMRESOTH Permit Fee: $1,617.00 Suppl. Insp. Fee -0 Reg. O OT 0,0 hrs $0.00 2,000 s.f. Re -roof $320.00 IREROOFRES PME Unit Fee: $0.00 PME Permit Fee: $0.00 P. [Itl:ift"dti'(it)f? lt:.i: E) Work Without Permit? 0 Yes 0 No $0.00 Advanced Planning Fee: IPLLONGR $75.18 Select a Non -Residential Building or Structure O O 4'' ,;rfn0.o i' ... Strong, Motion Fee: IBSEISMICR $12.20 Select an Administrative Item Bldy, Stds Commission Fee: IBCBSC $5.00 SUBTOTALS: $4,286.38 $1,364.00 TOTAL FEE: 1 $5,650.38 Revised: 08/01/2013 CUPERTINO CONTRACTOR / SUBCONTRACTOR LIST Building Department City Of Cupertino 10300 Torre Avenue Cupertino, CA 95014-3255 Telephone: 408-777-3228 Fax: 408-777-3333 JOB ADDRESS: (R -2S K STfZC—GT— PERMIT # t 30 100 6 f - OWNER'S NAME: HF—m,4 Ll N) —9kNKA- PHONE # 40& — GENERAL CONTRACTOR: Ljo • d BUSINESS LICENSE # ADDRESS: 119 (—� C7P4 Covc; UjCtX4 CITY/ZIPCODE: 5OAt-rV Com- I *Our municipal code requires all bMinesses working in fte city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: Signature Please check applicable subcontractors and complete the following information: Date I/ SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring / Carpeting Linoleum / Wood Glass / Glazing Heating Insulation Landscaping Lathing Masonry Painting / Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile r / Contractor Signature qr Date CUPERTINO CONTRACTOR / SUBCONTRACTOR LIST Building Department City Of Cupertino 10300 Torre Avenue Cupertino, CA 95014-3255 Telephone: 408-777-3228 Fax: 408-777-3333 JOB ADDRESS: PERMIT # OWNER'S NAME: c(/ PHONE # GENERAL CONTRACTOR: BUSINESS LICENSE # ADDRESS: � kl?A CITY/ZIPCODE: *Our municipal code requires all`fiusinesses worlAg in the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors. Signature Date Please check applicable subcontractors and complete the following information: �I'v Owner / Contractor Signature � 12,0 lJr' Date SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring / Carpeting Linoleum / Wood Glass / Glazing Heating Insulation Landscaping Lathing Masonry Painting / Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile �I'v Owner / Contractor Signature � 12,0 lJr' Date BUILDING ENERGY ANALYSIS REPORT PROJECT: Hema Sankar 825 Kim Street Cupertino, CA 95014 Project Designer: D -Cube Studio 1734 Winston Street San Jose, California 408-205-9812 Report Prepared by: Rick Rocklewitz NRG Compliance, Inc PO Box 3777 Santa Rosa, California 95402 707-237-6957 n COMPLIAN7 Job Number: 08171301 Date: 8/17/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft Job Number: ID: 08171301 User Number: 5581 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Hema Sankar Building Type m Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 8/17/2013 Project Address 825 Kim Street Cupertino California Energy Climate Zone CA Climate Zone 04 Total Cond. Floor Area 2,254 Addition 639 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ECJ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Floor Wood Framed w/Crawl Space R-19 639 New Wall Wood Framed R-13 471 New Door Opaque Door None 40 New Roof Wood Framed Attic R-30 639 New Floor Wood Framed w/Crawl Space None 1,615 Existing Roof Wood Framed Attic R-11 1,611 Existing Wall Wood Framed None 1,080 Existing Door Opaque Door None 18 Existing FENESTRATION U- Orientation Area fo Factor Exterior SHGC Overhang Sidefins Shades Status Front (E) 40.0 0.400 0.40 none none Bug Screen New Right (N) 3.0 0.400 0.40 none none Bug Screen New Skylight 4.0 0.550 0.67 none none None Existing Left (S) 55.0 0.550 0.67 none none Bug Screen Existing Rear (W) 101.0 0.550 0.67 none none Bug Screen Existing Right (N) 76.0 0.550 0.67 none none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78% AFUE Split Air Conditioner 11.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5,1 by Ener Soft User Number: 5581 RunCode: 2013-08-17T13:57:45 ID: 08171301 Pae 3 of 10 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Hema Sankar Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date $/17/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. Ener Pro 5.1 by EnerqVSoft User Number.- 5581 RunCode: 2013-08-17T13:57:45 /D: 08171301 Page 4 of 10 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type mSingle Family ❑ Addition Alone Date Hema Sankar ❑ Multi Family m Existing+ Addition/Alteration 8/17/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 57.91 52.36 5.55 Space Cooling 33.75 32.85 0.90 Fans 13.96 13.22 0.74 Domestic Hot Water 18.16 18.16 0.00 Pumps 0.00 0.00 0.00 Totals 123.77 116.58 7.19 Percent Better Than Standard: 5.8 BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 402 40 Fuel Available at Site: Natural Gas (S) 540 55 Raised Floor Area: 2,254 (W) 402 101 Slab on Grade Area: 0 (N) 540 79 Average Ceiling Height: 8.0 Roof 2,254 4 Fenestration Average U -Factor: 0.53 TOTAL: 279 Average SHGC: 0.63 Fenestration/CFA Ratio: 12.4% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author x Company NRG Compliance, Inc 8/17/2013 Address PO Box 3777 Name Rick Rock/ewitz City!State/Zip Santa Rosa, California 95402 Phone 707-237-6957 Si Rd Date The individual with overall design responsibility hereby certifies that the proposed b ilding design represented in this set of construction documents is consistent with the other compliance forms and work heets, with the specifications, and with any other calculations submitted with this permit application, and recognizes t at compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and b 'Iding envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) i Company D -Cube Studio Address 1734 Winston Street Name D -Cube Studio City/State/Zip San Jose, California Phone 408-205-9812 ig d License Date Ener Pro 5.1 by Ene Soft User Number. 5581 RunCode: 2013-08-17713:57:45 ID: 08171301 Pa e 5 of 10 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Hema Sankar Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration7D7ate 013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Floor 639 0.037 R-19 0 180 New 4.4.1-A4 First Floor Wall 162 0.102 R-13 90 90 New 4.3.1-A3 First Floor Door 40 0.500 None 90 90 New 4.5.1-A4 First Floor Wall 156 0.102 R-13 180 90 New 4.3.1-A3 First Floor Wall 153 0.102 R-13 0 90 New 4.3.1-A3 First Floor Roof 639 0.031 R-30 90 18 New 4.2.1-A20 First Floor Floor 1,615 0.097 None 0 180 Existing 4.4.1-A1 First Floor Roof 1,611 0.079 R-11 90 18 Existing 4.2.1-A2 First Floor Wall 142 0.356 None 90 90 Existing 4.3.1-A1 First Floor Door 18 0.500 None 90 90 Existing 4.5.1-A4 First Floor Wall 329 0.356 None 180 90 Existing 4.3.1-A1 First Floor Wall 301 0.356 None 270 90 Existing 4.3.1-A1 First Floor Wall 308 0.356 None 0 90 Existing 4.3.1-A1 First Floor Wall 242 0.356 None 90 90 Remove 4.3.1-A1 First Floor FENESTRATION SURFACE DETAILS ID Type Area Ll -Factor' SHGC Azm Status Glazing Type Location/Comments 1 Window 40.0 0.400 NFRC 0.40 NFRC 90 New Dual Vinyl LowE First Floor 2 Window 3.0 0.400 NFRC 0.40 NFRC 0 New Dual Vinyl LowE First Floor 3 Skylight 4.0 0.550 Default 0.67 Default 90 Existing Double Non Metal Clear First Floor 4 Window 55.0 0.550 Default 0.67 Default 180 Existing Double Non Metal Clear First Floor 5 Window 101.0 0.550 Default 0.67 Default 2701 Existing Double Non Metal Clear First Floor 6 Window 76.0 0.550 Default 0.67 Default 0 Existing Double Non Metal Clear First Floor (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC Hat Wd Ove hang Left Fin Right Fin Len Hat I LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 None 1.00 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 EnergyPro 5.1 by Ener Soft User Number: 5581 RunCode: 2013-08-17713:57:45 ID: 08171301 Page 6 of 10 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Hema Sankar Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 8/17/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existina I Altered Removed Volume Year Built HVAC S stem Addition 639 5,112 Existing 1,615 12,920 1959 Totals 6391 1,6151 0 01 1 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC System 1 Central Furnace 78% AFUE Split Air Conditioner 11.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Coolinq Duct Location R -Value Ducts Tested? Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas No Pipe Insulation 40,000 50 0.58 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 i� -0 n a System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number: 5581 RunCode: 2013-08-17713:57:45 0: 08171301 Pae 7 of 10 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Hema Sankar Date 1811712013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(i)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 5581 RunCode: 2013-08-17713:57:45 ID: 08171301 Page 8 of 10 .1 tr` MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Hema Sankar 8/17/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ftz or 100 watts for dwelling units larger than 2,500 ftz may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number. 5581 RunCode: 2013-08-17T13:57:45 /D: 08171301 Page 9 of 10 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Hema Sankar 8/17/2013 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (FMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 5581 RunCode: 2013-08-17713:57:45 ID: 08171301 Page 10 of 10 BUILDING ENERGY ANALYSIS REPORT PROJECT: Hema Sankar 825 Kim Street Cupertino, CA 95014 Project Designer: D -Cube Studio 1734 Winston Street San Jose, California 408-205-9812 Report Prepared by: Rick Rocklewitz NRG Compliance, Inc PO Box 3777 Santa Rosa, California 95402 707-237-6957 a :i COMPLIANCE, Job Number: 08171301 Date: 8/17/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Number: 5581 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary EnergyPro 5.1 by EnergySoft Job Number: ID: 08171301 User Number: 5581 2 3 8 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Hema Sankar Building Type m Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 8/17/2013 Project Address 825 Kim Street Cupertino California Energy Climate Zone CA Climate Zone 04 Total Cond. Floor. Area 2,254 Addition 639 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Floor Wood Framed w/Crawl Space R-19 639 New Wall Wood Framed R-13 471 New Door Opaque Door None 40 New Roof Wood Framed Attic R-30 639 New Floor Wood Framed w/Crawl Space None 1,615 Existing Roof Wood Framed Attic R-11 1,611 Existing Wall Wood Framed None 1,080 Existing Door Opaque Door None 18 Existing FENESTRATION U- Orientation Area(ft) Factor Exterior SHGC Overhang Sidefins Shades Status Front (E) 40.0 0.400 0.40 none none Bug Screen New Right (N) 3.0 0.400 0.40 none none Bug Screen New Skylight 4.0 0.550 0.67 none none None Existing Left (S) 55.0 0.550 0.67 none none Bug Screen Existing Rear (W) 101.0 0.550 0.67 none none Bug Screen Existing Right (N) 76.0 0.550 0.67 none none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78% AFUE Split Air Conditioner 11.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number. 5581 Run Code: 2013-08-17T13:57:45 ID: 08171301 Page 3 of 10 PERFORMANCE CERTIFICATE: Residential Part 2 of 5) CF -1 R Project Name Hema Sankar Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 1811712013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. Ener Pro 5.1 by Ener Soft User Number. 5581 RunCode: 2013-08.17713:57:45 0:08171301 Page 4 of 10 PERFORMANCE CERTIFICATE: Residential Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Hema Sankar 1 ❑ Multi Family m Existing+ Addition/Alteration 8/17/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kgtu/ft2- r Space Heating 57.91 52.36 5.55 Space Cooling 33.75 32.85 0.90 Fans 13.96 13.22 0.74 Domestic Hot Water 18.16 18.16 0.00 Pumps 0.00 0.00 0.00 Totals 123.77 116.58 7.19 Percent Better Than Standard: 5.8 BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 402 40 Fuel Available at Site: Natural Gas (S) 540 55 Raised Floor Area: 2,254 (W) 402 101 Slab on Grade Area: 0 (N) 540 79 Average Ceiling Height: 8.0 Roof 2,254 4 Fenestration Average U -Factor: 0.53 TOTAL: 279 Average SHGC: 0.63 Fenestration/CFA Ratio: 12.4% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company NRG Compliance, Inc 8/17/2013 Address PO Box 3777 Name Rick Rocklewitz� City/State/ZipCity/State/Zip Santa Rosa, California 95402 Phone 707-237-6957 Signed Date The individual with overall design responsibility hereby certifies that the proposed ' ing design represented in this set of construction documents is consistent with the other compliance forms and wor she ts, with the specifications, and with any other calculations submitted with this permit application, and recognize that 1compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and ildi�g envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company D -Cube Studio IL;_ Address 1734 Winston Street Name D -Cube Studio j. City/State/Zip San Jose, California Phone 408-205-9812 qned License # Date Ener Pro 5.1 by EnerqySoft User Number: 5581 Run Code: 2013-08-17713:57:45 /D: 081713AI Pae 5 of 10 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF -1 R Project Name Hema Sankar Building Type ® Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 8/17/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Floor 639 0.037 R-19 0 180 New 4.4.1-A4 First Floor Wall 162 0.102 R-13 90 90 New 4.3.1-A3 First Floor Door 40 0.500 None 90 90 New 4.5.1-A4 First Floor Wall 156 0.102 R-13 180 90 New 4.3.1-A3 First Floor Wall 153 0.102 R-13 0 90 New 4.3.1-A3 First Floor Roof 639 0.031 R-30 90 18 New 4.2.1-A20 First Floor Floor 1,615 0.097 None 0 180 Existing 4.4.1-A1 First Floor Roof 1,611 0.079 R-11 90 18 Existing 4.2.1-A2 First Floor Wall 142 0.356 None 90 90 Existing 4.3.1-A1 First Floor Door 18 0.500 None 90 90 Existing 4.5.1-A4 First Floor Wall 329 0.356 None 180 90 Existing 4.3.1-A1 First Floor Wall 301 0.356 None 270 90 Existing 4.3.1-A1 First Floor Wall 308 0.356 None 0 90 Existing 4.3.1 -Ai First Floor Wall 242 0.356 None 90 90 Remove 4.3.1 Al First Floor FENESTRATION SURFACE DETAILS ID Type I Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 40.0 0.400 NFRC 0.40 NFRC 90 New Dual Vinyl LowE First Floor 2 Window 3.0 0.400 NFRC 0.40 NFRC 0 New Dual Vinyl LowE First Floor 3 Sk li ht 4.0 0.550 Default 0.67 Default 90 Existing Double Non Metal Clear First Floor 4Window 55.0 0.550 Default 0.67 Default 180 Existing Double Non Metal Clear First Floor 5 Window 101.0 0.550 Default 0.67 Default 2701 Existing Double Non Metal Clear First Floor 6 Window 76.0 0.550 Default 0.67 Default 0 Existing Double Non Metal Clear First Floor (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-8 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC Hot Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len Hot Dist Len Hot 1 Bug Screen 0.76 2 Bug Screen 0.76 3 None 1.00 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number.- 5581 RunCode: 2013-08-17T13:57:45 /D: 08171301 Page 6 of 10 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Hema Sankar Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family 0 Existing+ Addition/Alteration Date 8117/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area fe New Existing_Altered I Removed Volume Year Built HVAC System Addition 639 5,112 Existing 1,615 12,920 1959 Totals 639 1,615 0 0 HVAC SYSTEMS System Name Qt . Heatin T pe Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC System 1 Central Furnace 78% AFUE Split Air Conditioner 11.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Cooling Duct Duct Location R -Value Ducts Tested? Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Tank Input Cap. Btuh al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas No Pipe Insulation 40,000 50 0.58 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 i� CQ Q — System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried Ener Pro 5.1 by EnergySoft User Number: 5581 RunCode: 2013-08-17T13:57:45 ID: 08171301 Page 7 of 10 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Hema Sankar Date 8/17/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no areater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-8 and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 5581 RunCode: 2013-08-17713:57:45 0: 08171301 Page 8 of 10 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Hema Sankar 1811712013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire as specified by § 150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 5581 RunCode: 2013-08-17713:57:45 0:08171301 Page 9 of 10 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Hema Sankar 8/17/2013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 5581 RunCode: 2013-08-17T13:57:45 0:08171301 Page 10 of 10