B-2017-0672 CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: CONTRACTOR: PERMIT NO:B-2017-0672
10507 MANZANITA CT CUPERTINO,CA 95014-6579(342 61 017) LA SOLAR GROUP INC
VAN NUYS,CA 91406
OWNER'S NAME: DO CALVIN TAND TRAN ALISSAT TRUSTEE DATE ISSUED:04/28/2017
•
OWNER'S PHONE:650-207-1899 PHONE NO:(818)359-5868
LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO:
License Class C-39 Lic.#974115
Contractor)..A SOLAR GROUP INC Date 06/30/2018 X BLDG X ELECT _PLUMB
• MECH X RESIDENTIAL COMMERCIAL
I hereby affirm that I am licensed under the provisions of Chapter 9(commencing — — _
with Section 7000)of Division 3 of the Business&Professions Code and that my ,
license is in full force and effect. JOB DESCRIPTION:
' INSTALL ROOF MOUNTED SOLAR SYSTEM((18 MODULES)(6.03
I hereby affirm under penalty of perjury one of the following two declarations: kW). -
1. I have and will maintain a certificate of consent to self-insure for Worker's REV#1-INSTALL 30 A NON FUSED AC DISC.;INSTALL(N)SUB-
Compensation;as provided for by Section 3700 of the Labor Code,for the PANEL(100 AMP)-ISSUED 8/31/2017
performance of the work for which this permit is issued.
I have and will maintain Worker's Compensation Insurance,as provided for by
1p Section 3700 of the Labor Code,for the performance of the work for which this
`�'1 permit is issued. Sq.Ft Floor Area: Valuation:$42000.00 . •
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above
information is correct.I agree to comply with all city and county ordinances APN Number: Occupancy Type:
and state laws relating'to building construction,and hereby authorize 342 61 017 , ,
representatives of this city to enter upon the above mentioned property for 1 '
inspection purposes. (We)agree to save indemnify and keep harmless the '•
City of.Cupertino against liabilities,judgments,costs,and expenses which PERMIT EXPIRES IF WORK IS NOT,STARTED
may'accr•ue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR
Additionally,the applicant understands and will comply with all non-point
source'regulations per the Cupertino Municipal Code,Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION.
I ,
Signatur Date 08/31-2017 Issued by:SEAN HATCH
Date:04/28/2017
OWNER-BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for one of the RE-ROOFS: I ;
following two reasons: All roofs shall be inspected prior to any roofing material being installed.If a roof is
i. I,as owner of the property,or my employees with wages as their sole installed without first obtaining an inspection,l agree to,remove all new materials for
compensation,will do the work,and the structure is not intended or offered for inspection
sale(Sec.7044,Business&Professions Code)
2. I,as owner of the property,am exclusively contracting with licensed Signature of Applicant:
contractors to construct the project(Sec.7044,Business&Professions Code). Date:08/31-2017
I hereby affirm under penalty of perjury one of the following three'declarations: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER
1. I have and will maintain a Certificate of Consent to self-insure for Worker's
Compensation,as provided for by Section 3700 of the Labor Code,for the '
performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE •
2. I have and will maintain Worker's Compensation Insurance,as provided for by I have read the hazardous materials requirements under Chapter 6.95'of the
Section 3700 of the Labor Code,for the performance of the work for which this California Health&Safety Code,Sections 25505,25533,,and 25534. I will
permit is issued. maintain compliance with the Cupertino Municipal Code,Chapter 9.:12 and the
3. I certify that in the performance of the work for which this permit is issued,I
Health&Safety Code,Section 25532(a)sl ould;1 store or handle hazardous
shall not employ any person in any manner so as to become subject to the material. Additionally,should I use equipment or devices which emithazardous
Disrdous
air contaminants as defined by the Bay Area,Air Quality Management District I
Worker's Compensation laws of California. If,after making this certificate of will maintain compliance with the Cupertino Municipal Code,Chapter9.12 and
exemption,I become subject to the Worker's Compensation provisions of the the Health&Safety Code,Sections 25505,25533,and 25534.
Labor Code,I must forthwith comply with such provisions or this permit shall
be deemed revoked. Owner or authorized ager . I' ' '
APPLICANT CERTIFICATION Date:08/31-2017 • i ! '
I certify that I have read this application and state that the above information is CON al UCTION LENDING AGENCY
correct.I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction Ilending;agency,forthe performance
relating to building construction,and hereby authorize representatives of-this city of work's for which this permit is issued(Sec.;3097,Civ C)
to enter upon the above mentioned property for inspection purposes. (We)agree Lender's Name ,
to save indemnify and keep harmless the City of Cupertino against liabilities,. Lender's Address
judgments,costs,and expenses which may accrue against said City in 1 '
consequence of the granting of this permit. Additionally,the applicant understands I i i ' •
and will comply with all non-point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION
Code,Section 9.18. I understand my plans shall be used as public records.
• ' Licensed -
Signature • Date 08/31-2017 Professional '
•
I'
. CONSTRUCTION PERMIT APPLICATION
. , \\t
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
..
( 10300 TORRE AVENUE • CUPERTINO,CA 95014-3255
g-C tss
w ' (408) 777-3228 • building@cupertino.org PEMIT#B- 2-014 - o6n,
CUPERTINO REV# -DEF#
❑ NEW CONSTRUCTION ✓ADDITION ❑ALTERATION ❑T.I. III MEP ❑RE-ROOF ❑SWIMMING POOL/SPA
PROJECT ADDRESS 166\b 1- IK 14 n t 0 _e Cm fit' euTtrikilo 8 M 1&13
4 APN# 9392, / _ --.0
I
OWNER NAME 8409 (00 PHONE t�QQ 20'_ 1919 E-MAIL i\ llCS/Gtl.V�I rt�ld @CZ UO.cD Y9
STREET ADDRESSprp"��'D (1- •
CITY, STATE,ZIP
VLt1'4.- tL 2 0-- ..
l ,iu4
❑CONTRACTOR NAME ❑OWNER-BUILDER COMPANY NAME 'LICENSE NUMBER LICENSE TYPE
.kt(4cli kritif l 9nt- 61,1-kiC C-.39 tit t qb .
I STREET ADDRESS CI I Y,STATE, ZIP I
e4' 3�' �C/u�i3 ►02cr 16�n � x elk Q 1 i o b
E-MAIL _� �p C PHONE (J BUS.LIC#
6\ @ P.,t,e4'-(Tn(-_1.eor� big' 313 Oo �-
❑ARCHITE ❑OWNER'[ OWNER AGENT 0 CONTRACTOR AGENT.❑ENGINEER❑DEVELOPER❑'TENANT '
CONTACT NAME fip n E-MAIL R g I gl jet ,,t„,• •to •
l G f
STREET ADDRESS C CITY,STATE,ZIP PHONE '
23$:7ns T.Vrerf 8L t,n �vtOt, ;g(a is,r. ,R 243
DECRIPTON U '
6,c 3ti o pe, ('-N`.4x,; ,Ae) t,yot,�e. c� - �s 4(kbn on equnrttti, ` l P�.. dun °st -
(3s0 ko,,v4- i\e„ 1,244ik 14-ditts • 1.4 b-d •-• (SytAjtAci Oen (Ilk 6-v't • '
SINGLE-FAMILY/DUPLEX 0 MULTI-FAMILY 0 INDUSTRIAL 0 COMMERCIAL
1
EXISTING USE EXISTING SF NEW FLOOR SF PORCH SF DECK SF DEMO SF STORIES# TOTAL NET SF USE TYPE OCC SQ.FT. VALUATION($)
ib '
REMODEL REMODEL KITCHEN REMODEL OTHR GARAGE ❑ATTACHED ' i
BATHROOM SF SF SF SF ❑DETACHED
IREEXISISPRINKLERS 1:1 NO NG 0 YES
EICHLER 0 YES NO SECOND STORY ADDITION 0 YES ,
• •
DWELLING SECOND DWELLING' ❑YES D ATTACHED 0 DETACHED OTHER
UNITS# UNIT ADDITON: ;'❑NO. S F
POOLS' ❑FIBERGLASS '❑VINYL-LINED ❑GUNTTE ❑PREFABRICATED .
POOL-SF SPA-SF I SPA ATTACHED ❑YES CI NO TOTAL-SF ' ,
RECE EDT TOTAL,VALUATION:
Commercial or Multi-Family.Buildings with Public Sdaimming Pools requires Department of Environmental Heath approval lei/44c
RE-R001 EXISTING ROOF TYPE: .EI BUILT-UP ROOF El ASPHALT SHINGLES❑WOOD SHAKES❑WOOD S NG LES❑TILE 0 (SPECIFY) 1
REMOVE/REPLACE 0 NO. IF NO PLYWOOD ❑'e ❑3/8" PLYWOOD TYPE: PITCH: ROOF CLASS
OYES #OF LAYERS ' THICKNESS E 5/8" OTHER LI OSB ❑CDX OTHER .12 ' A
PROPOSED ROOF TYPE:❑BUILT-UP ROOF PASPHALT SHINGLES ❑WOOD SHAKES❑WOOD SHINGLES 0 OTHER '
*Provide a signed copy of the Cupertino's Tear-Off Policy SF #of SQUARES
By my signature below I certify'to each of the following: I am the property owner or authorized agent to act on the'.property'owner's behalf: I
have read this application and the information I have provided is correct. I have read the Description of Work and;verify itis accurate. I agree
to comply with all applicable'local ordinances and state laws relating to building construction. I authorize representatives of:Cupertino to
enter the above-identified property for inspection purposes. I acknowledge and authorize all information containedlon this application form
to be made available for public record. �rr � I
Signature of Applicant/Agent: (' &goy) '�` �''' 0.��
`' � Date: i ,I
• SUPPLEMENTAL INFORMATION REQUIRED ''I I '
*New SFD/Second Dwelling Units/Multifamily Dwellings:A Demolition permit'is required prior to issuance of a building permit for,all new construction.
*Commercial Buildings: Provide alcompleted Hazardous Materials Disclosure form if any Hazardous Materials are being used asjpart of this project.
*Copy of Planning Approval Letter or Meeting with Planning prior to submittal of Building Permit application. • I , ,
*HOA-Provide a letter of approval front the Home Owner's Association ,
I ' i
BldgApp_2017.doc revised 08/01/17
CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2017-0672
10507 MANZANITA CT CUPERTINO, CA 95014-6579 (342 61 017) LA SOLAR GROUP INC
VAN NUYS, CA 91406
OWNER'S NAME: DO CALVIN TAND TRANALISSAT TRUSTEE
OWNER'S PHONE: 650-207-1899
LICENSED CONTRACTOR'S DECLARATION
License Class CAA/C-46 Lic. #974115
Contractor LA SOLAR GROUP INC Date 06/30/2018
I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing
with Section 7000) of Division 3 of the Business & Professions Code and that my
license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
n. I have and will maintain a certificate of consent to self -insure for Worker's
DATE ISSUED: 04/28/2017
PHONE NO: (818) 359-5868
BUILDING PERMIT INFO:
X BLDG —ELECT -PLUMB
— MECH X RESIDENTIAL _ COMMERCIAL
JOB DESCRIPTION:
INSTALL ROOF MOUNTED SOLAR SYSTEM ((18 MODULES)(6.03
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
Z I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. Sq. Ft Floor Area: Valuation: $42000.00
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above
information is correct. I agree to comply with all city and county ordinances
and state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above mentioned property for
inspection purposes. (We) agree to save indemnify and keep harmless the
City of Cupertino against liabilities, judgments, costs; and expenses which
may accrue against said City in consequence of the granting of this permit.
Additionally, the applicant understands and will comply with all non -point
source regulations per the Cupertino Municipal Code, Section 9.18.
Signature Date 4.28.17
following two reasons:
1. I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec.7044, Business & Professions Code)
2. I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec.7044, Business & Professions Code).
I hereby affirm under penalty of perjury one of the following three declarations:
1. I have and will maintain a Certificate of Consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the
Worker's Compensation laws of California. If, after making this certificate of
exemption, I become subject to the Worker's Compensation provisions of the
Labor Code, I must forthwith comply with such provisions or this permit shall
be deemed revoked.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws
relating to building construction, and hereby authorize representatives of this city
to enter upon the above mentioned property for inspection purposes. (We) agree
to save indemnify and keep harmless the City of Cupertino against liabilities,
judgments, costs, and expenses which may accrue against said City in
consequence of the granting of this permit. Additionally, the applicant understands
and will comply with all non -point source regulations per the Cupertino Municipal
Code, Section 9.18.
Date 4.28.17
APN Number: Occupancy Type:
342 61017
PERMIT EXPIRES IF WORK IS NOT STARTED
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
180 DAYS FROM LAST CALLED INSPECTION.
by: SEAN HATCH
RE -ROOFS:
All roofs shall be inspected prior to any roofing material being installed. If a roof is
installed without first obtaining an inspection, I agree to remove all new materials for
inspection.
Signature of
Date: 4.28.17
"All
HAZARDOUS MATERIALS DISCLOSURE
I have read the hazardous materials requirements under Chapter 6.95 of the
California Health & Safety Code, Sections 25505, 25533, and 25534. I will
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
Health & Safety Code, Section 25532(a) should I store or handle hazardous
material. Additionally, should I use equipment or devices which emit hazardous
air contaminants as defined by the Bay Area Air Quality Management District I
will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and
the Health & Safety Code, Sections 25505, 25533, and 25534.
Owner or authorized agent: ; A r
Date: 4.28.17 r
I hereby affirm that there is a construction lending agency for the performance
of work's for which this permit is issued (Sec. 3097, Civ C.)
Lender's Name
Lender's Address
ARCHITECT'S DECLARATION
I understand my plans shall be used as public records.
Licensed
Professional
r
ALTERNATIVE ENERGY PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 • building(a)cupertino.ong
OA- &ice 1� 9- ' I�) 61
PROJECT ADDRESS lf)g } ` ` 7 \ �_ � �� � tl fl
'1fPHONE
AP�N#t7
OWNERNAME /�� (
L
LJ �O�f rl��
E-MAIL. U'tonCd.hO+�IV�
STREET ADDRESS 4 }&JA 1
L
CITY, STATE, ZIP �9 U Y)' oil �R �r�i� f� _ l • t ��i r FAX
CONTACT NAME _ B _ �I
PHONE
E-MAIL
STREET ADDRESS
CITY, STATE, ZIP
FAX
❑ OwNER ❑ owNER-BUII,DER ❑ OWNER AGENT u CONTRACTOR- ❑ CONTRACTORAGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT
CONTRACTOR NAME ��� 47I)O P ((p�j
(�
LICENSE NUMBER �1" & p�
''T{ry��-"4r
LpICENSE TYPE
BUS. LIC #(}}
COMPANY NAME AA. &tAr, N19 C
E-MAIL
(7
@ l
Ut�* E63Yi
FAX
STREET ADDRESS fo p �1 @!t s
t
CITY, STATE, ZIP f OA '1 14 0 6
PHONE ft , 43 0041-
[i
ARCIIITECT/ENGINEER NAME p r K(T P(0 Y AAJ
LICENSE NUMBER L g� t�
f tfi2
BUS. LIC
i
_8
,
COMPANY NAME [�. CLA1�� �nyC
1
i"l cpi_
&MAIL � Ml hn
� � '(p In
FAX
STREET ADDRESS 4 p� � p U
NLJ C
CITY, STATE, ZIP
PHONE av g 3,-S bo
USE OF SFD Or Duplex ❑ Multi -Family
STRUCTURE: ElCommercial
PROJECT IN WILDLAND
URBAN INTERFACE AREA Elq� Yes li�No
PROJECT IN
FLOOD ZONE ❑ Yes 0 No
SOLAR PANELS
TO ELECTRIC VEHICLE CHARGING STATION
❑ SOLAR WATER HEATING
❑ OTHER:
FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: 1 KILOWATTS (COMMERCIAL ONLY): J ,y
TOTAL VALUATION:
DESCRIPTION OF WORK
6 ° 63 W 0C �g T��tohcF.�' i � .w) qk el�� f60 5k 4�
Int QK�� yA�)
t �k� t' t`u`J VI S
(9LE f) Paw -w w � `�'> akc Ae if Q k C@.4�-� NzA kq,
RECEIVED BY
By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this
application and the information I have provided is collect. I have read the Description of Work and.verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to building construct io authorize representatives of Cupertino to enter the above -identified property for inspection purposes.
jX �S p�bI
Signature of ApplicantfAgent: � Date: � 4 A9
SUPPLEMENTAL INFORMATION REQUIRED
OFFICE USKONILl
:OVER-THE-COUNTER ,
F'
❑ EXPRESS_ -
ca
❑ STANDARD - -
_ , ❑ LARGE
❑ MAJOR
PVApp_2411.doc revised 03116111
SMOKE I CARBON MONOXIDE ALAR
OWNER CERTIFICATE OF COMPLIANCE
COMMUNITY DEVELOPMENT
DEPARTMENT
BUILDING
G DIVISION
5
10300 TORRE AVENUE • CUPERTI cuaertino.og
PERTINC 777-3228 • FAX (408) 777-3333 • buildinaC4
CU 408)
_. .:...::....._. .... .. ...... -......SBE
. :... . .... ......... . . .. ....:::.....:. >,..: : -,�
...:.. � ..0 .:. �.,-,.,.T,.Tn�r•.RF,.FIL���ED-;.��.�� __ �m�;�F:.� CR�:.r�rn??T�IYIS
is ks'<Z„.1 C N:p'1
titl:'Attx!"q Pt' K^tT"Fy"wMtN !e :-
rn
PURPOSE r the installation of all required Smoke and Carbon
a1b � Where no interior accessLs o
This affidavit is aself-certification for R315, 2016 CBC Sections 420.6 and 907
compliance ,gith 2016 CRC Section 8314,
for inspections are required.
GENERAL INFORMATION
' to existing dwelling units exceeds
inti -family dwellings shall be provided with Smoke Alarms and Carbon
gusting single-family and m alterations, or repairs
Monoxide alarms. When the valuation of additions,
$1000.00, CRC Section 8314, R315, and
CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or
in the followinlocations:
Carbon Monoxide Alarms be installed g SMOKE ALARM CO ALARN1'i
AREA X X
each separate sleeping area in the immediate vicinity of the I
Outside of plocatedX X
room s) — (Smoke alarms shall not be �rW ntsana habitabf b le attro ics
door X
bed ( ,unit includin bas
never level of a dwelling
Within each sleep i , roon' -burrdng a liances and that
alarms are not required in dwellings which dnot
with moke alarms shall comply with
Carbon Monoxide ala Q Carbon monoxide alarms combined
do not have an �t6a�ddhall be app by the Office of the State Fire Marshal.
CBC Section 4_ alarm(s) may be solely battery operated.
units �1rith no commercial power supply,
Power Supply In d�"ellrng erated tivhere repairs or alterations do
finishes or there is no access by means °cattic,al basementis required for
In existing dtivelling Liruts, alarms are permitted to be solely battery oP to
not result in the removal of wall and ceiling
space. Refer to
CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An elec
alarms �-vhich must be connected to the building wiring- referenced above has/have been
and in compliance with the Californiaa , aslo the
As Owner of the above -referenced property, I herebcertify that the alarms ho
installed in accordance �.��ith the manufacturers instructions
Residential Codes. The alarms specified below have been tested and are opeT �2
and California Re � � _ -
date signed below. tJ� )IN i
Permit No.
address:
Carbon Monoxide Detectors:
Specify Number of Alarms:
r Smoke AlarnLs:
agree
to comply with the terms and conditions of this statementa � /
I have read and Ovrner (or Owner Ag.,nt s)Name:..................................Si^nature..........(�4
..........................
Contractor Name: ................. Lic.."+ ........................................ Dae: ...............
Signature.....................................................
Smoke and COfornl.doc rcvised 01/10,11=01:
CUPERTINO
WATER -CONSERVING PLUMBING FIXTURES
OWNER CERTIFICATE OF COMPLIANCE
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 77.7-3228 • FAX (408) 777-3333 • building a cupertino.oL9
Owner Name 4 I�%i N 11i) Permit No. ? `2-6 06 7
Address 1 ��'_ �L� i�?�� 114
Is your real property a registered historical site?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.
No Go to Question 2.
2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its
plumbing, installation of water -conserving plumbing fixtures is not technically feasible?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply.
❑ The licensed plumber's certification has been provided to the Building Division.
Skip the rest of the form and sign bottom of form.
'l No Go to Question 3.
Is water service permanently disconnected for your building?
El Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.
`® No Go to Question 4.
Is your real property built and available for use or occupancy on or before January 1, 1994?
❑ No My real property is built and available for use or occupancy after January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.
i Yes My real property is built and available for use or occupancy on or before January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign
bottom of form..
Please check ONE of the following:
1!p My property is a single family residential real property. See Civil Code Section 1101.4.
On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures
to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non-
compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether
properly undergoes alterations or improvements).
❑ My property is a multifamily residential real property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water -
conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or
unprovements).
❑ Myproperty is a commercial real property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving
plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements).
I, as the oNvner or owner's agent of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be
replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1
through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's
installation requirements, and that the water -conserving plumbing fixtures comply with the requirements as indicated in the
table on the following Ua2e. /
I Owner or Owner Agent's Signature: (by 1-\) y N ))'J Date: )1j. / 1% 1
Upon completing and signing flus Certificate, please return it to the Building Division in order to final your building permit.
SB407 2015.doc revised 01/05/17
RACKING SPECS
SHEET 11DRAWN BY:
DATE:
34261017
Single Family Residence
Ara Petrosyan
MAP SHEET INDEXCONTRACTOR
LA SOLAR GROUP, INC
ADDRESS: 16238 B Raymer St.,
Van Nuys, CA 91406
PHONE: (818) 373-0077
EMAIL: Engineering@lasolargroup.com
LIC TYPE: C-46, C-10, C-39
LIC #: 974115
PROPERTY INFORMATION
Ara Petrosyan
PROPERTY ADDRESS:
PARCEL NUMBER:
PROPERTY TYPE:
OWNER:
DRAWN BY:
DATE:
Calvin Do
10507 Manzanita, Court Cupertino, CA 65014
April 27, 2017
PHOTOVOLTAIC LAYOUT
PROPERTY PLAN
ATTACHMENT LAYOUT
SHEET 1
SINGLE LINE DIAGRAM
CODE REQUIRED SINGNAGE
MODULE DATA SHEET
MODULE CERTIFICATION
RACKING CERTIFICATION AND ATTACHMENT SPECS
SHEET 2
SHEET 3
SHEET 4
SHEET 5
SHEET 6
SHEET 7
SHEET 8
SHEET 9
SHEET 10
GROUNDING & BONDING DETAILS
MIDNITE SOLAR BOX DATA SHEET
6.03kW DC (5.42 kW AC) PHOTOVOLTAIC SYSTEM INSTALLATION ON EXISTING ROOF
18 SUNPOWER 335 WATT AC BLACK MODULES WITH FACTORY-INTEGRATED MICROINVERTERS
TWO STORY HOUSE
CONSTRUCTION TYPE: VB
OCCUPANCY GROUP: R3
· 2016 California Building Code
· 2016 California Residential Code
· 2016 California Green Building Standard Code
· 2016 California Plumbing Code
· 2016 California Mechanical Code
· 2016 California Electrical Code
· 2016 California Fire Code
· 2016 California Energy Code
· 2014 International Property Maintenance Code
All materials, equipment, installation and work shall comply with the following applicable codes:
2016 CBC / 2015IBC, - 2016 CRC / 2015 IRC, - 2016 CEC / 2014 NEC, - 2016 CMC / 2015 UMC, - 2016CPC/ 2015UPC, - 2016 CFC /
2015IFC, - 2016 Building Energy Efficiency Standards
● Existing plumbing vents, skylights, exhaust outlets, ventilations intake air openings shall not be covered by the solar photovoltaic
system.
● All outdoor equipment shall be NEMA 3R rated, including all roof mounted transition boxes and switches.
● All equipment shall be properly grounded and bonded in accordance with NEC article 250.
● All circuits connected to more than one source shall have over current devices located so as to provide over current protection
from all sources. [NEC 690.9(A)]
● The utility-interactive inverters shall automatically de-energize its output to the connected electrical production and distribution
network upon loss of voltage in the system and shall remain in that state until the electrical production and distribution network
voltage has been restored.[NEC 690.61]
● Due to the fact that PV modules are energized whenever exposed to light, PV contractor shall disable the array during installation
and service by short circuiting, open circuiting, or covering the array with opaque covering. [NEC 690.1(G)]
● All conductor exposed to weather shall be listed and identified for use in direct sunlight. [NEC 690.31(B), 3i-0.8(D)]
● The module conductors must be type USE-2 or listed for photovoltaic (PV) wire. [NEC 690.31(B)]
● All conductors shall be marked on each end for unique identification. [NEC 690.4 (B)]
● All grounded conductor shall be properly color identified as white. [NEC 200.6]
● PV system connected on the load side of the service disconnecting means of the other source(s) at any distribution equipment on
the premises shall meet the following [NEC 705.12(D)]:
- Each source connection shall be made at a dedicated circuit breaker or fusible disconnecting means. [NEC 705.12(DX1)]
- The sum of the ampere rating of the over current devices in circuits supplying power to the bus bar or conductor shall not exceed
120% of the rating of bus bar or conductor. [NEC 705.12(D)(2)]
- The interconnection point shall be on the line side of all ground-fault protection equipment. [NEC 705.12(D)(3)]
- Equipment containing over current devices in circuits supplying power to a bus bar or conductor shall be marked to indicate the
presence of all sources. [NEC 705.12(D)(4)]
- Circuit breaker, if back fed, shall be suitable for such operation. [NEC 705.12(DX5)]
● To minimize overheating of the bus bar in panel board, the panel board main circuit breaker and the PV power source circuit
breaker shall be physically located at the opposite end of the bus bar.[NEC 705.12(DX7)]
● Marking and Labeling Methods and Locations. The labels or markings shall be visible after installation. The labels shall be reflective,
and all letters shall be capitalized and shall be a minimum height of 9.5 mm (3⁄8 in.) in white on a red background. 690.31 (4)
● Flexible, fine-stranded cables shall be terminated only with terminals, lugs, devices or connector that are identified and listed for
such use. [NEC 690.3].(F) & 110.14(A)]
● Connectors shall be of latching or locking type. Connectors that are readily accessible and operating at over 30 volts shall require
tool to open and marked "Do Not Disconnect Under Load" or "Not For Current interrupting”. [NEC 690.33(C) & (E)(2)]
● Equipment grounding conductor for PV modules smaller than 6AWG shall be protected from physical damage by a raceway or
cable armor. [NEC 690.45 & 250.120(C)]
● Equipment grounding conductor for PV systems without Ground Fault Protection (GFP) and installed on non-dwelling unit must
have ampacity of at least 2 times the temperature and conduit fill corrected circuit conductor ampacity, [NEC 690.45(B)]
● Fine-stranded cables used for battery terminals, devices, and connections require lugs and terminals listed and marked for the
use. [NEC 690.74 (A)]
● A directory is not required where all inverters and PV disconnecting means are grouped at the main service disconnecting
means, since the disconnects would all be located in close proximity to each other. NEC 690.4(D)
● Fuses and Fixed-Trip Circuit Breakers. The standard ampere ratings for fuses and inverse time circuit breakers shall be
considered 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250, 300, 350, 400, 450, 500, 600, 700,
800, 1000, 1200, 1600, 2000, 2500, 3000, 4000, 5000, and 6000 amperes. 690.9(A)
● Protection devices for PV source circuits and PV output circuits shall be in accordance with the requirements of 690.9(B)
through (E).
● Listed PV overcurrent devices shall be required to provide overcurrent protection in PV source and output circuits. The
overcurrent devices shall be accessible but shall not be required to be readily accessible. 690.9 (D)
● Equipment that performs the rapid shutdown shall be listed and identified. 690.12 The rapid shutdown initiation methods shall
be labeled in accordance with 690.56(B)
● PV source circuits and PV output circuits shall not be contained in the same raceway, cable tray, cable, outlet box, junction box,
or similar fitting as conductors, feeders, branch circuits of other non-PV systems, or inverter output circuits, unless the conductors of
the different systems are separated by a partition. NEC 690.31(B)
● Direct-Current Photovoltaic Source and Direct-Current Output Circuits on or Inside a Building. 690.31 (G)
GENERAL NOTES
SEAN HATCH
04/28/17
04/28/17
B-2017-0672
SEAN HATCH
Project Name and Address
No. Revision/Issue Date
General Notes
Project Sheet
Date
Scale
PV SYSTEM
AS INDICATED 1
CONTRACTOR:
Drawn By :
Ara Petrosyan
Lic # 974115
Ara Petrosyan
N
S
W E
Calvin Do
10507 Manzanita, Court
Cupertino, CA 65014
April 27, 2017
SOLAR MODULES
___ SunPower 335 Watt
Model #SPR-X21-335-BLK-C-AC (240V)
18
INVERTER
INVERTER TYPE: Micro:
___ FACTORY-INTEGRATED
MICROINVERTERS
Model #SPR-X21-335-BLK-C-AC (240V)
18
JB (N) Junction Box
EMT type Conduit
Fire Setback Line
INDEX
PHOTOVOLTAIC
LAYOUT
MSP (E) _____ Main Service Panel400APV ARRAY
MSB (N) 120A MidNite Solar Box
LA Solar Group
16238 B Raymer St.,
Van Nuys, CA 91406
Phone: (818) 373-0077
LIC TYPE: C-46, C-10, C-39
1'-6"
3'
1'-6"PV Array
18 SunPower 335 W
AC Modules
Tilt: 18 Deg
Azimuth: 210 Deg
MSP
MSB
0 5' 10'
2'' Pipe will be rerouted
(See Details on Page #3)
Existing Thermal Panels
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
JB
SEAN HATCH
04/28/17
Project Name and Address
No. Revision/Issue Date
General Notes
Project Sheet
Date
Scale 2PV SYSTEM
AS INDICATED
CONTRACTOR:
Drawn By :
Lic # 974115
Ara Petrosyan
Calvin Do
10507 Manzanita, Court
Cupertino, CA 65014
April 27, 2017
PROPERTY
PLAN
DRIVEWAY
POOL
LEGEND
MSB MidNite Solar Box
MSP Main Service Panel
Ara Petrosyan
LA Solar Group
16238 B Raymer St.,
Van Nuys, CA 91406
Phone: (818) 373-0077
LIC TYPE: C-46, C-10, C-39
0 5' 10'
N
SW
E
BARN
132'
142'
58'
65'
33'
30'
PROPERTY LINE
17'
18' 67'
58'
71'
MSB
MSP
Midnite Solar Box
EQUIPMENT ELEVATION
SEAN HATCH
04/28/17
Project Name and Address
No. Revision/Issue Date
General Notes
Project Sheet
Date
Scale 3PV SYSTEM
AS INDICATED
CONTRACTOR:
Drawn By :
Lic # 974115
Ara Petrosyan
Calvin Do
10507 Manzanita, Court
Cupertino, CA 65014
April 27, 2017
ATTACHMENT
LAYOUT
NOTE: MAXIMUM ATTACHMENT DISTANCE 6'-0''
SHEATHING
ROOF PENETRATION SEALED
WITH APPROVED SEALANT
TILE TRAC
L-FOOT
PV RAIL
3/8" * 3.5" LAG SCREW STAINLESS STEEL
MIN. 2.5" EMBED INTO FRAMING MEMBER
TILE TRAC ATTACHMENT DETAILS
1 Layer of ___________
Plywood & Building Felt
DF#2 2"x4" - 24" O.C.
SOLAR MODULE6"
ATTACHMENT
DF#2 2"x6"
BLOCKING
DF#2 2"x4"
Reroute using 45 Deg. fittings facing skyward, no
horizontal pipe runs under module or 90 degree
fitting. New upright pipe
18°
MODULES ON ROOF
S-Tile
Ara Petrosyan
LA Solar Group
16238 B Raymer St.,
Van Nuys, CA 91406
Phone: (818) 373-0077
LIC TYPE: C-46, C-10, C-39
INVISIMOUNT RAIL
6'
ATTACHMENTS
2" BY 4''
TRUSSES
24" O.C.
SEAN HATCH
04/28/17
Project Name and Address
No. Revision/Issue Date
General Notes
Project Sheet
Date
Scale 4PV SYSTEM
AS INDICATED
CONTRACTOR:
Drawn By :
Lic # 974115
Ara Petrosyan
Calvin Do
10507 Manzanita, Court
Cupertino, CA 65014
April 27, 2017
GROUNDING
& BONDING
DETAILS
LA Solar Group
16238 B Raymer St.,
Van Nuys, CA 91406
Phone: (818) 373-0077
LIC TYPE: C-46, C-10, C-39
Ara Petrosyan
SEAN HATCH
04/28/17
5
CONTRACTOR:
Drawn By :
Lic # 974115
Ara Petrosyan
Calvin Do
10507 Manzanita, Court
Cupertino, CA 65014
SINGLE LINE
DIAGRAM
BRANCH CIRCUIT #1
PV ARRAY
10 SUNPOWER
335W AC MODULES
10 FACTORY-INTEGRATED
MICROINVERTERS
1
2
J BOX
NEMA3R SUNPOWER TRUNK CABLE
(2) #12 AWG PV WIRE
FREE IN THE AIR
(4) #10 AWG THWN/THWN-2
(1) #8 AWG GND
3/4" EMT, 60 FEET
10
(2) #10 AWG THWN/THWN-2
(1) #8 AWG GND
3/4" EMT, 5 FEET_____ BUSUTILITY
M MAIN METER
EXISTING
______ MAIN
SERVICE PANEL
120/240V,
1P, 3W
NOTE: Service Panel does not contain center
fed Main breaker.
EXISTING
NON CENTER _____
MAIN C/B
GROUND ELECTRODE(S) TO
BE 5/8 DIAMETER X10'-0''
LONG EMBEDDED A MINIMUM
OF 8'-0'' DIRECTLY INTO SOIL
PER ART. 250.53(G)400A 200A
30AINSTALL ____ 2P CB(PV)
INSTALL AT OPPOSITE
END OF BUS FROM
MAIN FEEDER CB
400A
· If there is a cold water bonding and UFER, no
additional supplementary rod is required
· If there is no UFER, new ground rod shall be installed
· If existing ground rod is more than 25 OHM, than a
new ground rod shall be installed
MIDNITE SOLAR BOX
120/240V, NEMA 3R
(See Datasheet on Page 7)
INSTALL (2) 20A PV
2-POLE C/B
120A BUSProject Name and Address
No. Revision/Issue Date
General Notes
Project Sheet
Date
Scale
PV SYSTEM
AS INDICATED
April 27, 2017
Ara Petrosyan
PV MONITORING DEVICE
(if applicable)
Main Panel Suitable for
Back feed - NEC 705.12(D)(3)LA Solar Group
16238 B Raymer St.,
Van Nuys, CA 91406
Phone: (818) 373-0077
LIC TYPE: C-46, C-10, C-39
BRANCH CIRCUIT #2
ARRAY
8 SUNPOWER
335W AC MODULES
8 FACTORY-INTEGRATED
MICROINVERTERS
1
2
8
SEAN HATCH
04/28/17
6AS INDICATED
CONTRACTOR:
Drawn By :
Lic # 974115
Ara Petrosyan
Calvin Do
10507 Manzanita, Court
Cupertino, CA 65014
SIGNAGE
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM
THE FOLLOWING SOURCES WITH
DISCONNECTS LOCATED AS SHOWN :
CAUTION
North
WARNING PLAQUE
INVERTER TYPE: Micro
SunPower 335 W AC
Module System
SOLAR PHOTOVOLTAIC
MAIN SERVICE
PV SYSTEM
Project Name and Address
No. Revision/Issue Date
General Notes
Project Sheet
Date
Scale
Ara Petrosyan
SIGNAGE
PHOTOVOLTAIC REQUIREMENTS
PER CALIFORNIA ELECTRICAL CODE ARTICLE 690
PHOTOVOLTAIC SYSTEM DISCONNECT
RATED AC OUTPUT CURRENT - 29.93 AMPS
AC NORMAL OPERATING VOLTAGE 240 VOLTS
WARNING
DO NOT TOUCH TERMINALS ON BOTH
LINE AND LOAD SIDES MAY BE
ENERGIZED IN THE OPEN POSITION
WARNING
ELECTRIC SHOCK HAZARD.
DO NOT TOUCH TERMINALS.
TERMINALS ON BOTH THE LINE AND
LOAD SIDES MAY BE ENERGIZED IN THE
OPEN POSITION.
Marking shall be placed on interior and
exterior DC conduit, raceways, enclosures
and cable assemblies every 10 ft (3048 mm)
within 1 ft (305 mm) of turns or bands and
within 1 ft (305 mm) above and below
penetrations of roof/ceiling assemblies,
walls or barriers.
COMBINER /
JUNCTION
BOX
ON
ARRAY
WARNING
DO NOT TOUCH TERMINALS ON BOTH
LINE AND LOAD SIDES MAY BE
ENERGIZED IN THE OPEN POSITION
OFF
DC
DISCONNECT
(if applicable)
DC DISCONNECT
INVERTER
(if applicable)
ON
OFF
AC
DISCONNECT
WARNING:
PHOTOVOLTAIC POWER SOURCE
WARNING
RATED OUTPUT CURRENT 29.93 AMPS
AC NORMAL OPERATING VOLTAGE 240 VOLTS
This lable is to be located adjacent to the PV breaker
36'' to 75'' above the floor or grade
level to center of performance meters
(IF APPLICABLE)
SERVICE
METER
METER
SOCKET
(if applicable)
WARNING:
PHOTOVOLTAIC POWER SOURCE
WARNING
INVERTER OUTPUT
CONNECTION. DO NOT
RELOCATE THIS
OVERCURRENT DEVICE
OPTIONAL SOLAR P.V.
ONLY COMBINER
PANEL BOARD
PV SUB PANEL
(if applicable)
WARNING
PHOTOVOLTAIC SYSTEM - DO NOT
RELOCATE THIS BREAKER
WARNING
ELECTRIC SHOCK HAZARD.
IF GROUND FAULT IS INDICATED
NORMALLY GROUNDED
CONDUCTORS MAY BE
UNGROUNDED AND ENERGIZED.
Solar Source Only
No Other Loads in
This panel
CEC 690.5(C)
CEC 690.14(C)(2)
PHOTOVOLTAIC
SYSTEM DISCONNECT
CEC 690.17
WARNING
ELECTRIC SHOCK
HAZARD. THE DC CONDUCTORS
OF THIS PHOTOVOLTAIC SYSTEM
ARE UNGROUNDED AND MAY BE ENERGIZED.
CEC 690.35(F)
CEC 690.14(C)(2)
PHOTOVOLTAIC
SYSTEM DISCONNECT
CEC 690.54
WARNING
DUAL POWER SOURCES SECOND SOURCE IS
PHOTOVOLTAIC SYSTEM
CEC 690.64(B)(4)
690.64(b)(7)
PHOTOVOLTAIC SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
690.56
April 27, 2017
LOCUS METER
LA Solar Group
16238 B Raymer St.,
Van Nuys, CA 91406
Phone: (818) 373-0077
LIC TYPE: C-46, C-10, C-39
CEC. 5. MAKINGS, LABELS AND WIRING SIGNS.
A. Purpose: Provide emergency responders with appropriate warning and guidance with respect to isolating solar electric system.
This can facilitate identifying energized electrical lines that connect solar panels to the inverter, as these should not be cut when venting for smoke removal
B. Main Service Disconnect.
1. Residential buildings - The marking main be placed within the main service disconnect. The marking shall be placed outside cover if the main service disconnect is operable with the service
panel closed.
2. Commercial buildings - Tha marking shall be placed adjacent to the main service disconnect clearly visible from the location where the level is operated.
3. Markings: Verbiage, Format and Type of Material.
a. Verbiage: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED
b. Format: White lettering on a red background. Minimum 3/8 inches letter height. All letters shall be capitalized. Arial or similar font, non bold.
c. Material: Reflective, weather resistant material suitable for the environment (use UL - 969 as standard for weather rating). Durable adhesive materials meet this requirement.
C.Marking Requirements on DC conduit, raceways, enclosures, cable assemblies, DC combiners and junction boxes:
1. Markings: Verbiage, Format and Type of Material.
a. Placement : Markings shall be placed every 10 feet on all interior and exterior DC conduits, raceways, enclosures, and cable assemblies, at turns, above and for below penetrations, all DC combiners
and junction boxes
b. Verbiage: CAUTION: SOLAR CIRCUIT Note: The format and type of material shall adhere to "V. V-3b, c" of this requirement.
c. Inverters are not required to have caution markings
1. Marking is required on all interior and exterior DC conduit, raceway, enclosures, cable assemblies, and junction boxes, combiner and disconnects.
2. The materials used for marking shall be reflective, weather resistant material suitable for the environment.Minimum 3/8" letter height; all upper case letters Arial or similar font; Red
background with wight lettering.
3. Marking shall contain: WARNING: PHOTOVOLTAIC POWER SOURCE.
4. Marking shall be placed adjacent to the main service disconnect in a location clearly visible from the location were the disconnect is operated.
FIRE DEPARTMENT REQUIREMENTS
PV SYSTEM DISCONNECT
FOR UTILITY OPERATION
SERVICE POINT &
UTILITY METERING
SOLAR PHOTOVOLTAIC
ARRAY ON ROOF
EXISTING
THERMAL PANELS
SEAN HATCH
04/28/17
Project Name and Address
No. Revision/Issue Date
General Notes
Project Sheet
Date
Scale 7PV SYSTEM
AS INDICATED
CONTRACTOR:
Drawn By :
Lic # 974115
Ara Petrosyan
Calvin Do
10507 Manzanita, Court
Cupertino, CA 65014
April 27, 2017
MIDNITE SOLAR
BOX DATA SHEET
MIDNITE SOLAR BOX DATA SHEET
Ara Petrosyan
LA Solar Group
16238 B Raymer St.,
Van Nuys, CA 91406
Phone: (818) 373-0077
LIC TYPE: C-46, C-10, C-39
SEAN HATCH
04/28/17
Project Name and Address
No. Revision/Issue Date
General Notes
Project Sheet
Date
Scale 8PV SYSTEM
AS INDICATED
CONTRACTOR:
Drawn By :
Lic # 974115
Ara Petrosyan
Calvin Do
10507 Manzanita, Court
Cupertino, CA 65014
April 27, 2017
MODULE
DATA SHEET
MODULE DATA SHEET
Ara Petrosyan
LA Solar Group
16238 B Raymer St.,
Van Nuys, CA 91406
Phone: (818) 373-0077
LIC TYPE: C-46, C-10, C-39
SEAN HATCH
04/28/17
Project Name and Address
No. Revision/Issue Date
General Notes
Project Sheet
Date
Scale 9PV SYSTEM
AS INDICATED
CONTRACTOR:
Drawn By :
Lic # 974115
Ara Petrosyan
Calvin Do
10507 Manzanita, Court
Cupertino, CA 65014
April 27, 2017
MODULE
CERTIFICATION
MODULE CERTIFICATION
Ara Petrosyan
LA Solar Group
16238 B Raymer St.,
Van Nuys, CA 91406
Phone: (818) 373-0077
LIC TYPE: C-46, C-10, C-39
SEAN HATCH
04/28/17
RACKING
SPECS
RACKING SPECS
Project Name and Address
No. Revision/Issue Date
General Notes
Project Sheet
Date
Scale 10PV SYSTEM
AS INDICATED
CONTRACTOR:
Drawn By :
Lic # 974115
Ara Petrosyan
Calvin Do
10507 Manzanita, Court
Cupertino, CA 65014
April 27, 2017
Ara Petrosyan
LA Solar Group
16238 B Raymer St.,
Van Nuys, CA 91406
Phone: (818) 373-0077
LIC TYPE: C-46, C-10, C-39
SEAN HATCH
04/28/17
RACKING
CERTIFICATION
AND ATTACHMENT
SPECS
RACKING CERTIFICATION
Project Name and Address
No. Revision/Issue Date
General Notes
Project Sheet
Date
Scale 11PV SYSTEM
AS INDICATED
CONTRACTOR:
Drawn By :
Lic # 974115
Ara Petrosyan
Calvin Do
10507 Manzanita, Court
Cupertino, CA 65014
April 27, 2017
ATTACHMENT SPECS
Ara Petrosyan
LA Solar Group
16238 B Raymer St.,
Van Nuys, CA 91406
Phone: (818) 373-0077
LIC TYPE: C-46, C-10, C-39
SEAN HATCH
04/28/17