Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
B-2017-0222
CITY OF CUPERTINO BUILDING R RMIT BUILDING ADDRESS: — CONTRACTOR: PERMIT NO: B-2017-0222 1173 STAFFORD DR CUPERTINO, CA 9501414968 (362 06 027) WILLOW GLEN ELECTRIC INC SAN JOSE, CA 95115 OWNER'S NAME: MUKERJI PINAKI AND MEENAKSM I! [ DATE ISSUED: 02/07/2017 OWNER'S PHONE: 408-394-1177 �i PHONE NO: (408) 289-9725 LICENSED CONTRACTOR'S DECLARATION BUILDING PE u T INFO: License Class C-10 Lic. #591918 Contractor WILLOW GLEN ELECTRIC INC Date 04/30/2018 X BLDG _E T _PLUMB I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing MECH X RESIt ENTIAL COMMERCIAL with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTI N: EV CHARGII�i STATION (50 AMPS) IN GARAGE t I hereby affirm under penalty of perjury one of the following two declarations: I i 1. I have and will maintain a certificate of consent to self-insure for Worker's ,rr Compensation, as provided for by Section 3700 of the Labor Code, for the I `f erformance of the work for which this permit is issued. J n ll.7 I have and will maintain Worker's Compensation Insurance, as provided for by C)/JJ Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Sq. Ft Floor Area; f Valuation: $5440.00 APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances APN Number: j Occupancy Type: and state laws relating to building construction, and hereby authorize 362 06 027 representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non-point WITHIN 1'' .Q DAYS OF PERMIT ISSUANCE OR source regulations per the Cupertino Municipal Code, Section 9.18. 180 DAYS OM LAST CALLED INSPECTION, Signature Date 2/7/2017 Issued by: A A end f OWNER-BUILDER DECLARATION Date: 02/07/2017,1 I hereby affirm that I am exempt from the Contractor's License Law for one of theRE-ROOFS: following two reasons: All roofs shall be in Iiected prior to any roofing material being installed. If a roof is 1. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Sec.7044, Business-& Professions Code) 2. I, as owner of the property am exclusively contracting with licensed Signature ofApplicaiIf contractors to construct the project (Sec.7044, Business &Professions Code). Date: 20 I i I hereby affirm under penalty of perjury one of the following three declarations: ALL ROO COVERINGS TO BE CLASS "A" OR BETTER 1. I have and will maintain a Certificate of Consent to self-insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the j performance of the work for which this permit is issued. tUIZARDOUS MATERIALS 2. I have and will maintain Worker's Compensation Insurance, as provided for by I have read the ba 'ardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code, for the performance of the work for which this California Heajti' maintain complian II& Safety Code, Sections 25505, 25533, and 25534. I will a with the Cupertino Municipal Code, Chapter 9.12 and the permit is issued. Health & Safety I ode, Section 25532(a) should I store or handle hazardous 3. I certify that in the performance of the work for which this permit is issued, I material. Additioq y, should I use equipment or devices which emit hazardous shall not employ any person in any manner so as to become subject to the air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If, after making this certificate of will maintain comp ' a nce with the Cupertino Municipal Code, Chapter 9.12 and exemption, I become subject to the Worker's Compensation provisions of the the Heal' Safety Code, Sections 25 05, 25533, and 25534. Labor Code, I must forthwith comply with such provisions or this permit shall i I , be deemed revoked. , Ow" ner or authori��e d agent: APPLICANT CERTIFICATION 'Date: 2/7/2017 1 certify that I have read this application and state that the above information is I hereby affirm that, ONSTRUCTION LENDING AGENCY ere is a construction lending agency for the performance correct, I agree to comply with all city and county ordinances and state laws of work's for which his permit is issued (Sec. 3097, Civ C.) relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name I� to save indemnify and keep harmless the City of Cupertino against liabilities, Lender's Addres$i f I judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal 1 understand my pl1 ARC HITECT'S DECLARATION ns shall be used as public records. Code, Section 9.18. Licensed li Signature Date 2/7/2017 Si 9 Professional � / /Al 1-t,%-, % J f 00 CUPSRTINO � I I ALTERNATIVE ENERGY PERMIT APP I ICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING D1 SII I�SION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • tluilcii . L�c;tl�ie ►�1)i�;.41).�'; I� lu AE PROJECT ADDRESS Z)(/a I i APN OWNER NAME JyA �t/J PHONW%0i ,?4" 1 y ® E-MAIL STREETADDRE5S SWFOa A dA I FAX CONTACT NAMEPHONE Mark Londre (408)289.9725 If E-MAIL I office @wiAow lenelectric.com STREET ADDRESS r9 ®' ��x p4r30 CITY, STATE, ZIP C+an Jose, �A 95155 FAX (448)289-9725 ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT CONTRACTOR ❑ CONTRACTOR AGENT ❑ A CHITF.CT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LOndre77-7 LICENSE NUMBER 591918 LICiNSETYPE C-10 BUS. LIC# 15897 COMPANY NAME llow Alen Electric, Inc. Willow E-MAIL office@willowigieh, I lectric.com FAX (408)289-9725 STREET ADDRESS P. ®. Box 8430 CITY, STATE, ZIP Jose, Jose, �7 f 95155 PHONE / G \4Ov)�yV.7"97G5 ARCHITECT/ENGINEER NAME N/A LICENSE NUMBER ' AUS. LIC COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP j PHONE USE OF 7 SFD or Duplex ❑ Multi -Family STRUCTURE: ❑ Commercial PROJECT IN WILDLAND URBAN INTERFACE AREA ❑ Yes I ❑ NO PROJECT IN FLOOD ZONE 171Yes 171No El SOLAR PANELS S1 ELECTRIC VEHICLE CHARGING SjA LON ❑ SOLAR WATER HEAT II I I G ❑ OTHER: FOR SOLAR PANELS. NUMBL•'ROFPANELS/UNrFS: KILOWATTS (COMMERCIAL ONLY): TOTALVALUATIO DESCRIPTION OF WORK t/ Electric Vehicle Char in Circuit: xa-� )1-t ° \� i l ii i J 1 /ill '7 6A -P-46 4-167 `7`/1 [_r4 -:S , BY' �I By my signature below, I certify to each of the following: I am the property owner or authorized agent to act application and the information I have provided is correct. I have read the Description of Work and verify it is ordinances and state laws relating to building const m ' I 2Aize epres res of Cupertino to enter th, Signature of Applicant/Agent: Date: t1 he property owner's behalf. I have read this ,ccurate. I agree to comply with all applicable local above -identified property for inspection purposes. N. 1 r ,�.2 SUPPLEMENTAL INFORMATION REQUIRED I �11 Ili OFFICE USE ONLY OVER -TW CQYTQITER Q- EXPRESS 0 ,STANDARD ❑ LARGE © MAJOR'; PVApp_2011.doc revised 03/16111 y a :—. r •••uvov-�i uv rc�tr-.4,0,ubuuubl uti,t, \ SMOKE/ CARBON MONOXIDE-,ALARMS OWNER CERTIFICATE OF COMPLIANCE �SK.rpf COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION CUPERTINO 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 (408)777-3228•FAX(408)777-3333•buildinq(a?.cupertino.orq Permit No.B-2017-0222 Address 1173 Stafford Drive, Cupertino #of Alarms Smoke: 5 Carbon Monoxide: 4 PERMIT CANNOT BE FINALED AND COMPLETED UNTIL THIS CERTIFICATE HAS BEEN SIGNED AND RETURNED TO THE BUILDING DIVISION PURPOSE This affidavit is a self-certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION - Existing single-family and multi-family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations,or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the X X bedroom(s) On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel-burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply:In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic,basement or crawl space.Refer to CRC Section R314 and CBC Sections 907:2.11.4 and 420.6.2.An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above-referenced property, I hereby certify that the alarm(s)referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes.The alarms have been tested and are operational,as of the date signed below. I have read and agree to comply with the terms and conditions of this statement Owner(or Owner Agent's)Name: Docusigned by: n,. Meenakshi Mukerji Signatur AI $.IA�L.IY�t U(ji Dat /21/2017 Contractor Name: 3B652B70FEF0446... Signature Lic.# Date: Smoke and CO form doe revised 03/18/14 uuuuoign tnvelope iv zi ecuu9D-6766-424A-B45E-D500C51C6979 , 4 101.6,// ' WATER-CONSERVING PLUMBING FIXTURES 11> OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING[VISION CUPERTINO 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 (408)777-3228•FAX(408)777-3333•buildineicupertinti.brq Owner Name Meenakshi MUkerji Permit No. B-2017-0222 Address 1173 Stafford Drive, Cupertino, CA 950114 PERMIT CANNOT BE FINALED AND COMPLETED UNTIL THIS CERTIFICATE - HAS BEEN SIGNED AND RETURNED TO THE BUILDING DIVISION Please refer to the attached California Civil Code Sections 1101.1- 1101.8 which are part of this Certification form. I. Is your real property a registered historical site? 0 Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. ,..---DocuSigned by:. Owner' Signature: . Date: 2/21/2017 [3 No Go to Question 2. M-t-t-IAASttA klAttAt L--3B652B70FEF0446.. 2. Does your real property have a licensed plumber certifying that,due to the age or configuration of the property or its plumbing,installation of water-conserving plumbing fixtures-is not technically feasible? O Yes Civil Code Sections 1101.1 through 1101.8 do not apply. 0 The licensed plumber's certification has been provided to the Building Division. Sign below and skip the rest of the form. "--DocuSigned by: Owner'Signature: ktuutt s(ti kikuji Date:2/21/2017 [3 No Go to Question 3. , .----313652B7OFEF0446.. 3. Is water service permanently disconnected for your building? O Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner'Signature:r—DocuSigned by: Date: 2/21/2017 [3 No Go to Question 4. IktunAs(ci Ilitulcuiji '.--3B6521370FEF0446.. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? O No My real property is built and available for use or occupancy after January 1, 1994, 1 Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. DocuSIgned by: Owner' Signature: ikt-thAtS6 ,,,A.,,,t LDate:2/21J2017 N Yes My real property i iiinentbevailable for use or occupancy on or before January 1, 1994. • Civil Code Sections 1101.1 through 1101.8 apply. Refer to the attached. 0 My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non-compliant plumbing fixtures shall be replaced with water-conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). 0 My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1,2014,specified building alterations or improvements shall require non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures. On or before January 1,2019,all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building(regardless of whether property undergoes alterations or improvements). 0 My property is a commercial real property. See Civil Code Section 1101.5. - On and after January 1,2014,specified building alterations or improvements shall require non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures. SB407 2015.doc revised 02/04/15 DodaSign'Envelope ID:21CCDO9D-6766-424A-B45E-D50005106979 On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water-conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). 1/We,the owner(s)of this property,certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water-conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8,the current California Plumbing Code and California Green Building Standards Code,and manufacturer's installation requirements,and that the water-cons ' pyltittg fixtures comply with the requirements as indicated in the table below. Owner's(or Owner Agent's)Signature Alit-Un4E.St t ki tXt t Date?/11/2 0.0 38652B70FEF0446... Upon completing and signing this Certificate,please return it to the Building Division in order to final your permit. Non-Compliant Water-Conserving Plumbing Fixture Plumbing Fixture1 (Fixture Complying with Current Code Applicable to New Construction) Maximum Water Usage/Flow Rate Fixture Type 2013 CPC Ch.4 2013 CPC Ch.4 2013 CPC Ch.4 Water Usage 2013 CALGreen Div.4.3 2013 CALGreen Div.4.3 2013 CALGreen Div.5.3 /Flow Rate Single-Family Multi-Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume(the composite, average flush volume of two reduced flushes and one full flush) Urinals Exceed 1.0 0.5 gallons/flush Gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower,the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi,or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets— Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute @60 psi Faucets— Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute '1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi,and must gallons per minute @ default to maximum 60 psi,and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable,aerators or reduction. other means may be used to achieve reduction. 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown,it is not required to be upgraded. Ij SB40720I5doc revised 02/04/15 Install one 240 Volt 200 Amp overhead, flush mounted panel upgrade in place of the existing 100 Amp electrical panel. Includes new grounding electrode system, overhead service conduit mast and connections, and circuit breakers that will match the preexisting wire sizes. The new ground wire will be routed in the most straight- forward way from the main electrical panel to the existing water main, as required by code. Install one 240 Volt 50 Amp dedicated circuit with a NEMA 14-50 receptacle in the front left corner of the ygari P'+rF/ging-This; circuit will provide 40 continuous �.. �5 .. �.� r fit c iargmg: ur,6ce-mounted 3/4II EMT w/ #6 THWN conductors & #10 THWN ground will be used on the exterior of the home, and inside the garage, to route the circuit from above t ._ r-maI.+ r r(ii al.:,}aneI to the new NEMA 14-50 receptacle b'ar'' :.. LAI] tl��ilan:a:.]ly .71�, i_: -i.., ',:=�e,••u,';' . 1-,'.. ..... Ira -12'; 1 ( Au1 eqj cq ] , I ,, 12 House Aff 200A Main Panel (N) w/ 50A breaker (N) 3/4" EMT w/ #6 THWN conductors #10 THWN ground (N) Garage Pinaki Mukerji 1173 Stafford Dr Cupertino CA 950.4 (408) 896-5266 NEMA 14-50 Receptacle (N) Driveway TONVI-Id OO.400'3 NO-, 1 I�11 11t ; a Tlir. WOLUIJUCIOG NjipI!nEj Meenakshi Mukerji Page ( 200A Main Panel (N) w/ 50A breaker (N) 3/4" EMT w/ #6 THWN conductors #10 THWN ground (N) Garage Pinaki Mukerji 1173 Stafford Dr Cupertino CA 950.4 (408) 896-5266 NEMA 14-50 Receptacle (N) Driveway Residential Electrical Load Calculation Site Location: prepared by 11MILLOW Plnaki Mukerji Willow Glen Electric, Inc. L 8 N 1173 Stafford Dr PO Box 8430 L 8 C 7 R I C Cupertino CA 95014 San lose, CA 95155 �/ 1 (408)896-5266 (408)289 -9725 -office f General Lighting and Receptacle Loads [220.12] 3 watts per ft' x 2,236 = 6,714 Small -Appliance Branch Circuits [220.52(A), 21CA(C)(1[I 1,500 watts x 2 = 3,000 Laundry Branch CircUit(5) [220.521B), [210.11(C)(2)] 1,500 watts x 1 = 1,500 11,214 Fastened -In -Place Appliances Kitchen _ Bath(s) outisde/Miscellaneous [220.53] Refrlgcrator(s) = 780 Instant Hot H20(s) = Exhaust Fan(s) = Hot Tub = Dishwasher(s) = 969 Hood Exhaust(s) = Jacuzzl Tub(s) = Pool Equipment = Garbage Disposal(s) = 60D Gas Range(s) = Radiant Heating = Central Vacuum = Microwavo(s) = 1,200 'Gas Gven(s) = Steam shower = Sewage Ejector = Trash Compactor = Wine Frldge(s) = Sauna = 30ACimuit = Steamer = _ - Garden shed = Total Fastened -in-place Appliance Load 3,540 Clothes Dryer(S) [220.54[ 80% x 240 x Derating Volts Amps 51000 OR Name Plate Rating of Clothes Dryer = 5,000 Ranges, Ovens, Cooktops, and Other Household Cooking Appliances [220.551 601/6 x 240 x 50 = 9,600 Derating Volts AND/OR Name Plate Rating of Cooking Appliances = Heating or Air -Conditioning System (Compare the heat and A/C, and omit the smaller.) [220.60] Air Handler/Furnace 11s x 6,0 = Volts Amps Air Conditioners 5,970 55% x .240 x 40 - Derating Volts AND/OR Name Plate Rating of Air Handler & AC Units = Tota[ Volt -Ampere Demand Load [220.83] Greater of: Air-cond itiontng Equipment 5,970 x 100% = 5,970 Electric Space Heating - x 100% _ First 8kVA of all other loads 8,000 x 1DD% = 8,000 Remaindercf all other loads 21,354 x 44% = 8,542 22,512 Total Current Minimum Amperes 22,512 _ 240 = 93,8 Current Minimum 100 Amps (voltage) (minimum amperes) 17 Size Service or Feeder [240.6(A)] - - -currently Electric Vo 1ff41 3ONVI1C�WO0:1100,11H ()-A f"I:4AA�])„-,`- lzsu x Continuous Load zoo x Volts = Amps 12,000 Minimum Amperes with Adijed Load, t - ii r Mimmum3ize �Ii1J J4' Divide the foto! _ _, ;522 + 24a - 1418 5eruiie or Feeder 206 Amps volt-amperes by ,,y = ' (�fa� [minimum amperes) 20 w/Added Load with added load the voltage. rh rr. `r l [240.6{A]] - piee NOTES !all_LH` dn,,, .; All References are to 2014 National Electrical Code. INSTALLING YOUR 244 VOLT OUTLET F AuiluiN Departrrient REV(EV'VEL: '-OR C:C)I)E CC?M PLIAMCE The recommended home charging Installatlon for Tesla vehicles is a 240 Volt NEMA 14• t'0v 50 outlet. This outlet Is commonly used for electric ranges and large recreational vehicles. Installed with a 50 -amp circuit breaker, this outlet enables a recharge rate of about 25 miles per hour. Consult a Ilcensed electrician to review the electrical load of your home prior to Installation. They will design your charging system and obtain a permit for a general Purpose NEMA 1450 outlet from your local building department, After Installation, the electrician will schedule an Inspection to approve the new electrical circuit and design. This guide provides reference for specifications to install this outlet. Since each Installation Is custom to the home, all hardware for the NEMA 14.50 outlet will be Provided by your electrician, GROUND To Top NEMA 14-50 DETAILS • voltage: Single phase, 208-260 Volt AC supply, 60 hertz a Circuit Breaker: 80 amp (125% overcurrent protection) • Operating Current; 40 amp (maximum continuous current) • Conductors: 0 AWG, Copper Wire Only, Upsize wiring for Installations over 150 feet • Ground Fault Circuit Interrupter: Not required • Service Disconnect: Not required • Receptacle Recommendation: High quality, Industrial grade receptacle Examples: Hubbell part # HBL940A, Cooper part #5754N • Ventilation: Not required 0 Outdoors; Install with NEMA 3R rainproof enclosure RECOMMENDED LOCATIONS CHARGE PORT PlEXOMMENDED LOCATION FOR 240 VOIJ OUTLET T551—A ADDITIONAL RESOURCES EMAIL C:I-lARGINGINS TALL4TI0N@1TE9LA.CCM PHONE 650-6131,613-'3 (M. -F") 24/7 'TECH SUPPORT 877.798,:5752 WEB .rE:5LA.00M/StJI,-,poI:T ONLINE STORE SHC)RTI:; LA,C,Olvi 45500 Fremont Boulevard, Fremont, CA 94538 1 May, 2016 1 Version 3