B-2017-0032CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2017-0032 22600 RICARDO RD CUPERTINO, CA 95014-5447 (356 01 004) ARGON CONSTRUCTION INC MORGAN HILL, CA 95037 OWNER'S NAME: WENDT CRISTOPHER KAND WOLFGRAM TRINA J TRU OWNER'S PHONE: 408-497-0553 \. 1 11\ is 1 141-111001 . R41411[09 License Class GENERAL BUILDING CONTRACTOR Lic. #508042 Contractor ARGON CONSTRUCTION INC Date 03/31/2017 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: 1. I have and will maintain a certificate of consent to self -insure for Worker's as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. FD - i1XFIiS�ii hereby affirm that I am exempt from the Contractor's License Law for one of the illowine two reasons: 1. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION certify that I have read this application and state that the above information is correct. lagree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date 1/5/2017 ISSUED: 01/05/2017 NO: (408) 778-6835 BUILDING PERMIT INFO: X BLDG —ELECT —PLUMB _ MECH X RESIDENTIAL _ COMMERCIAL JOB DESCRIPTION: 1 ST FLOOR HALLWAY BATHROOM REMODEL (30 S.F.) Sq, Ft Floor Area: Valuation: $10000.00 "N Number: Occupancy Type: 356 01 004 PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Issued by: ABBY AYENDE Date: 01/05/2017 RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: 1/5/2017 ALL ROOF COVERINGS TO BE CLASS "A" OR HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Sections 25505, 25533, an 5534. i Owner or authorized agent: Date: 1/5/2017 I hereby affirm that thereat a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professional CUPERTINO CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(@cupertino.org ❑ NEW CONSTRUCTION ❑ ADDITION ❑. ALTERATION /TI (—I REVISION /DEFERRED ORTCUNAT.PFRMTT# PROJECT ADDRESS Q f6'lC - - - APN # /1 e ®'0C)q e®JS3 PHONE OWNERNAME-Z IA � W ®i O - E-MAIL STREET ADDRESS CITY, STATE, ZIP FAX CONTACT NAME PHONE STREET ADDRESS CITY, STATE, ZIP FAX ❑ OWNER ❑ OWNER -BUILDER ❑ OWNERAGENT 9 -CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME_ LICENSE NUMBER LICENS E BUS. LIC # Z4410 I p 46 � � COMPANY NAME �/ E-MAIL F ,c+ ��^/W l O"'� �C�C.iv!✓O� �-�/�� e fi®P� STREET ADDRESS27 � e ® fele- r s CITY, ST TE J / �� C� •�L/ PHONE e rte. `## ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OF WORK EXISTING USE PROPOSED USE CONSTR. TYPE # STORIES I USE TYPE OCC, SQ.FT. VALUATION (S) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA NET AREA BATHROOM KITCHEN OTHER REMODEL AREA ,�J� REMODEL AREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: DETACH I ❑ ATTACH ,','DWELLING UNITS: IS A SECOND UNIT ❑ YES SECOND STORY E] YES BEING ADDED? []NO ADDITION? ❑NO PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF IS THE BLDG AN ❑ YESIVED BY:,'s:: TQTAL VALUUATTION: PLANNING APPL # ❑ NO PLANNING APPROVAL LETTER EICHLER HOME? ❑ NO By my signature below, I certify to each of the following: I am the property owner or authorized age -A,$ act on the property owner's behalf. I have read this application and the information I have provided is correct. Pave read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to b ' dinlo constructi . I e representatives of Cupertino to enter the above -identified property for inspection purposes. Signature of Applicam/Agent: Date: �® �5 ®— 7 SUPPLE INF RMATION REQUIRED PLAN cicx TYPE ROUTING SLIP EI 0VER-TIiE-COUNTER _ El-BUH DING rLAxxEsTEv. _ New SFD or Multifamily dwellings: Apply for demolition permit for existing building s). Demolition permit is required prior to issuance of building permit for new building. ❑ EXPRESS ❑. PLANNING PLAN REVIEW Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ STANDARD ❑ -:PUBLIC ivoxxs _- Tom—.i if any Hazardous Materials are being used as part of this project. [] LARGE ❑ - FIRE DEPT. Copy of Planning Approval Letter or Meeting with Planning prior to ID ❑ sAI,IT CRY sEvvERnrsTRlcT submittal of Building Permit application. -MAJOR -- ' ❑•-EIQVIRON�HEALTH=- BldgApp_2011.doc revised 06121111 SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE > CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(a.cupertino.org PERMIT CANNOT BE IlINALED UNTIL THIS CERTIFICATE BIAS BEEN CQMPLETED�IGN, AND RETUIRNEj2TO THE BUILDING DIVISION PURPOSE This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms specified below have been tested and are operational, as of the date signed below. Address: 2 tl ®��� . �� Permit No. f0t 7_0®-3 Z - T Specify Number of Alarms: # Smoke Alarms: # Carbon Monoxide Detectors: 1 1 / have read and agree to comply with the terms and conditions of this statement Owner (or Owner Agent's) Name: ���// Signature ...... ./../.S:%...�....(... .:.... l Date: Q -C "1 ........... ............ ...... ......... . Contractor Name: t� Signature.... .... ....... ..... ... ................... Lic.# . � ? . .. . ....... Date: �) . ............... ........ ... ....................................... Smoke and CO foi-in.doc revised 09/27116 Owner Name WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 FAX (408) 777-3333`• building@cupertino.ora Address Address 5 C-06 ®aS -Z— 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form W�o Go to Question 2. 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the properly or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form. ll�N0 Go to Question 3. 3. Is water_ service permanently disconnected for your building? W0ElCode Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. Go to Question 4. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form.. Plea'eheck ONE of the following: LAY My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I, as the owner or owner's agent of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's .nstallation requirements, and that the water -conserving plumbing fixtures comply with the requirements as indicated in the table on the following pace. Owner or Owner Agent's Signature: f/yi'--;� Date: �_ Upon completing and signing this Ce f �,5 flelret:rn it to the Building Division in order to final your building permit. SB4072015.doc revised 08/26/15 i. It the existing plumbing texture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB407 2015. doc remised 08/26115 Non -Compliant Water -Conserving Plumbing Fixture PlumbingFixture (Fixture Complying with Current Code Applicable to New Construction) Fixture Type Maximum Water Usage/Flow Rate 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CPC Ch. 4 Water Usage /Flow Rate 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 Single -Family Multi -Family Commercial Residential Residential Wafer Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 Gallons/flush 0.5 gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets — Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute 60 psi Faucets — Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to rr aximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. i. It the existing plumbing texture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB407 2015. doc remised 08/26115