Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
B-2016-2079
.4. CITY OF UPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2016-2079 10435 DEMPSTER AVE CUPERTINO, CA 95014-1224 (326 48 014) SLINGSHOT POWER INC LOS ALTOS, CA 94022 OWNER'S NAME: KIRLOSKAR VIRENDRA AND ANJALI TR STEE DATE ISSUED: 06/07/2016 OWNER'S PHONE: 408-221-8271 ( PHONE NO: (650) 308-9055 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class CC=10 Lie. #984488 Contractor SLINGSHOT POWER INC Date 06/30/2017 X BLDG _ELECT _PLUMB MECH X RESIDENTIAL _ COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapte 9 (commencing with Section 7000) of Division 3 of the Business &Professions Coe and that my license is in full force and effect. JOB DESCRIPTION: (l) 10 PANEL ROOF -MOUNTED PV SYSTEM (3.0 KW) I hereby affirm under penalty of perjury one of the following twoeclarations: 1. I have and will maintain a certificate of consent to self -ins a for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. -1 have and will maintain Worker's Compensation Insuranc , as provided for by Section 3700 of the Labor Code, for the performance of th work for which this Sq. Ft Floor Area: Valuation: $11400.00 permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the abov information is correct. I agree to comply with all city and county ordinances APN Number: Occupancy Type: and state laws relating to building construction, and hereby authorize 326 48 014 representatives of this city to enter upon the above mentioned roperty for inspection purposes. (We) agree to save indemnify and keep armless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. ion WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally, the applicant understands and will comply with all -point source regulations per the Cupertino Municipal Code, Section E.18. 180 DAYS FROM LAST CALLED INSPECTION. Signature/✓v l i Date 6 2 16 Issued by: Abb A end Date: 06/07/2016 OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is following two reasons: i. I, as owner of the property, or my employees with wages a their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not inended or offered for inspection. sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting witli licensed Signature of Applicant: contractors to construct the project (Sec.7044, Business & professions Code). Date: 6/7/2016 I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1. 1 have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labpr Code, for the performance of the work for which this pei4�qit is issued. i HAZARDOUS MATERIALS DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code, for the performance of th� work for which this California Health & Safety Code, Sections 25505, 25533, and 25534. I will permit is issued. maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the 3. I certify that in the performance of the work for which this permit is issued, I Health & Safety Code, Section 25532(a) should I store or handle hazardous shall not employ any person in any manner so as to becom� subject to the material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If, after making this certificate of will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and exemption, I become subject to the Worker's Compensati provisions of the the Health & Safety Code, Sections 25505, 25533, and 25534. Labor Code, I must forthwith comply with such provisioor this permit shall J _ be deemed revoked. c ;Owner or authorized agent: / APPLICANT CERTIFICATION Date: 6/7/2016 I certify that I have read this application and state that the above information is CONSTRUCTION LENDING AGENCY correct. I agree to comply with all city and county ordinances acid state laws I hereby affirm that there is a construction lending agency for the performance to building construction, and hereby authorize represe tatives of this city of work's for which this permit is issued (Sec. 3097, Civ C.) to enter upon the above mentioned property for inspection pur oses. (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino aga nst liabilities, judgments, costs, and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally, the apjlicant understands and will comply with all non -point source regulations per the Cu ertino Municipal ARCHITECT'S DECLARATION Code, Section 9.18. 1 understand my plans shall be used as public records. Licensed Signature Date 6/7/2016 Professional ALTERNATIV ENERGY PERMIT APPLICATION JA COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISIONA1= 10300 TORRE AVEN E • CUPERTINO, CA 95014-3255 (408) 777-3228 • FP.X'(408) 777-3333 • buildinala�ouoertino.org CUPERTI O q PROJECT ADDRESSi e I APN R •2,7-6 V� PH/ONE !O� � (jV(' JZ f M?.IL 1 � � i /� Q� I FAX STREET ADDRESS 4i'� y� J /> //� � ` ✓ (..{' CITY, STATE, t, ZIPLkj�) A CONTACT Nva ECh rl-5& � CC C/v� laf-0 K=4l6i/� S T R:ET r'.DDRESS CITY, STATE, ZIP I FAX ❑ oWIv:.R ❑ 01lNcR-3Ly)E$ ❑ OWKzPLAGEI 1 KCONTI24CTOR E CONrMkCTORAGE? 1 ❑ .kRC:1TcCT ❑ ENGTTER ❑ DEIE-LOPER ❑ icwyr CONTR 10"` ��V�� L]C'jSEhICEN$E�YPE I BUS. LIC 4' CO .?�NYWJAE / wer I EMAIL I FPY o SR i`� DD�6'GG{ l(I ' C�TYdRESSStTE, IP kELIis PHONE ARCHITECT/ENGLNEER NPa!E I LICENSE N1121BER BUS. LIC,, COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF ❑ SFD or Duplex ❑ 'Multi-Famil PROMCT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN IN, t.RFACE AREA ❑ Yes ❑ No FLOOD ZONE ElYes E3No �SOLA.R PANELS U -) ELECTP.IC VEHICL't CY 4RGING STATION ❑ SOLAR 1 ATER HEATING ❑ OTHER: FOR SOL1_R PANELS: NUMBER OF ?AN LS/U ,1TS: \ KILOWA7 iS (COM?,iRCIAL ONL)7: O TOTP.L VALUATION:,, f Liu �/ V .DESCRIPTION OF WORK 07 By my signature below, I ce tifyto each o? the following: ) am the property ol4ne.r or authorized agent to act on the property owner's behalf I have reed this application and the information I have provided is correct, have read the Description of Work and verity it is accurate. I agree to comply with all applicable local ordinances and state laws relating o building construction. I aut rize representatives of Cupertino to enter the above-identi ted prope, , for inspection purposes. '�l 7116 5 i mature of„pplicant/Agent: Date: SUPPLEMENTAL r-NF0R4ATIO1\I REQUIRED mo flt O�ERSHP COULTER;, ❑3.PRESS rZ ,4 ` al a cTA%D�StDs tc k - _Ua < ` ZSRGE E ] _- . n _ e PT!4pp_2011.doc revised 03/16/11 ABBREVIATIONS ELECTRICAL NOTES GENERAL NOTES SCOPE OF WORK aD S A AMPERE 1. A NATIONALLY RECOGNIZED 1. THIS SYSTEM IS GRID -TIED WITH A SLINGSHOT POWER IS TO INSTALL A AC ALTERNATING CURRENT TESTING LABORATORY SHALL LIST ALL UL LISTED POWER CONDITIONING ROOF MOUNTED PV ARRAY. O ART ARTICLE EQUIPMENT IN COMPLIANCE WITH ART INVERTER BLDG BUILDING STRUCTURE 110.3 2. THIS SYSTEM HAS NO BATTERIES. CONTRACTOR ADDRESS .t t CONC CONCRETE 2. ALL EXTERIOR EQUIPMENT SHALL NO UPS SLINGSHOT POWER DC DIRECT CURRENT BE RAIN TIGHT AND APPROVED FOR USE 3. ALL WORK SHALL COMPLY WITH 164 MAIN ST EGC EQUIPMENT GROUNDING IN WET CONDITIONS THE 2013 CALIFORNIA BUILDING CODE LOS ALTOS, CA 94022 CONDUCTOR 3. BACKFEED BREAKER MUST BE AND THE 2013 CALIFORNIA RESIDENTIAL 800.8M�94u14�, n� N! i DEVELOPMENT DEPARTMENT (E) EXISTING LOCATED AT THE OPPOSITE END OF CODE; CSLB #Cs46E9&.44s88ON-CUPERTINO (n EMT ELECTRIC METALLIC TUBING BREAKER OR LUGS PROVIDING POWER 4. ALL WORK SHALL COMPLY WITH APPROVED GALV GALVANIZED FROM THE UTILITY THE 2011 NATIONAL ELECTRIC CODE AS S%,�tofpians�TSYeFa,1IEptatthe GEC GROUNDING ELECTRODE 4. DC CONDUCTORS ENTERING A AMENDED BY THE 2013 CALIFORNIA _416t W UJTJLITY,-:,in3 cPP,G-8aEon. it is unlawful to make any U CONDUCTOR BUILDING WILL BE RUN IN METALLIC ELECTRIC CODE changes or I' a.ions on same, or to deviate HOA: '.. NAY Z t� a,rom, withou approval from the Building Official. GND GROUND RACEWAYS TO THE FIRST ACCESSIBLE 5. LOCAL UTILITY SHALL BE ��r LLj 2 W Th s ncp of this pian and specifications SHALL NOT W HDG HOT DIPPED GALVANIZED MEANS OF DISCONNECTION PER ART CONTACTED PRIOR TO ENERGIZATION �� i;�id to permit or to be an approval of the violation F— (n Q e-,ld t I CURRENT 690.31 (E) OF THE SYSTEM of a provisions of any City Ordinance or state Law. W . Icont CONTINOUS CURRENT 5. ALL CONDUCTORS SHALL BE ice- BY jh� Lin U � Im MAX POWER CURRENT P PROVIDED WITH STRAIN RELIEF UPON _ (n DATE 20 0 0 Is SHORT CIRCUIT CURRENT ENTRY INTO ENCLOSURES. PERr�ITNo. ,�_ N kVA KILOVOLT AMPERE 6. EACH UNGROUNDED CONDUCTOR CU 0 W N W ' kW KILOWATT SHALL BE IDENTIFIED BY PHASE AND -1 0 C) LBW LOAD BEARING WALL SYSTEM PER ART 210.5 — M MAX MAXIMUM 7. WHERE ALL TERMINALS OF THE SHEET INDEX o Y o MIN MINIMUM DISCONNECTING MEANS SHALL REMAIN C6 Q r- •1r, N<' NEUTRAL ENERGIZED IN THE OPEN POSITION, A PV01 COVER SHEET =: NEC - "NATIONAL ELECTRIC CODE WARNING SIGN SHALL BE PROVIDED PV02 SITE PLAN Q NTS NOT TO SCALE PER ART 690.17 SLOT pNS 01E PV03 ARRAY DETAILS PV LI_NE�-DIAGRAM- -- I�}EW-- - __ _ =8=—THE--=9C GROUNSIIVG-ELECTRE3D - = - - -04 — - OC ON CENTER CONDUCTOR SHALL BE SIZED PER ART 447.# . LBLS LABELS PL PROPERTY LINE 690.47 AND 250.66(8) ��� DATA SHEETS ATTACHED POI POINT OF 9. MODULE FRAMES SHALL BE INTERCONNECTION GROUNDED AT THE UL -LISTED LOCATIONS TIN J PTC PVUSA TEST CONDITIONS PROVIDED BY THE MANUFACTURER? Lo CO PV PHOTOVOLTAIC USING UL -LISTED HARDWARE' ❑ -q-W 2 o CO PVC POLYVINYL CHLORIDE 10. ALL METALLIC COMPONENTS VICINITY > Y W co uj w w SCH SCHEDULE SHALL BE GROUNDED VIA ELECTRIC a o z = 0� 0[f SS STAINLESS STEEL GROUNDING CONDUCTORS AND CUPERTINO L W W o _1 > z w J a w w w STC STANDARD TES CONDITIONS GROUNDED AT THE MAIN SERVICE Building pePa►trnen LizTYP _ � Y� `. ` # REVISION DATE - TYPICAL SUN 2015 a 0 Original 6/6176 Al_ UPS UNINTERRUPTIPLE POWER REVIEWED B C - - SUPPLY FOR OR CODE COMPLIANCE D - - V VOLT Reviewed By. �. E - - I Vmp MAX POWER VOLTAGE L E VOC OPEN CIRCUIVT O TAG ;doe #: isTaoss DESIGN: RDECGADO • , ?Ky r;p'. W WA TT - - - r. �•_ PAGE: COVER PAGE PAGE NUMBER PV01 n�. X14 , M AC 0 DRIVEWAY MP1 LLIEl Q W H B c/) W C/) W 0 a = O LL 0 I— z 0 o O - L.L �. JUN 0 7 2016 REVIEWED FOR CODE COMPLIANCE Reviewed By: C- CONDUIT RUN ON THE ROOF IN COMPLIANCE WITH 2013 CEC 690.31 & 2013 CRC R331.3 (EXACT RUN TBD AT INSTALL). CUPER TINO Building Department J_ Q Q'NO(n WU00 > o> Q W W CLMZC-W W J d W W W REVISION DA Original 6/6 #:13774066 PAGE: SITE PLAN SITE PLAN PAGE NUMBER PV02 W U z W W P- (n Q W C� 00N > U) V U) N W ' 0 C) Y M O It Cao z Q J_ Q Q'NO(n WU00 > o> Q W W CLMZC-W W J d W W W REVISION DA Original 6/6 #:13774066 PAGE: SITE PLAN SITE PLAN PAGE NUMBER PV02 # CONDUCTORS CONDUIT LENGTH PROPERTIES NOTES A (1) ENGAGE CABLE, (1) #6 BARE EGC N/A 5' DC: Vmax=39.7, Vmp=32.5, Imax=9.7, Imp=9.26 B (2) #10 THWN-2, (1) #10 N, (1) #8 EGC/GEC 3/4" EMT 50' AC: V=240, BRANCH #1: 1=10A U Q- C (2) #8 THWN-2, (1) #8 N, (1) #8 EGC/GEC 3/4" EMT 5' AC: V=240, BRANCH #1: 1=10A a� J co) V (E) MAIN SERVICE 100A, 240/120V, 1 �, 3W SYSTEM POC SYLVAN IA I LSCO IPC 1/042 W U UNDERGROUND SERVICE FEED Z METER NO.: 1006521104 W W (E) 100A/2P U j w a U)IY� oNo B E T RANCH TERMINATOR O ��� C B A N UUP \ ENGAGE 0 dam' M L1 CABLE _ _ _ _ - - Lo M TO (E) BRANCH #1 o Y o SUBPANEL L2 O I 0 I 10 MODULE O I O I cY Q C) _ _ N N N z G — — — — — — — — — G EGC EGC — — Q - I -- - - GEC - - 240/120V (10) PV MODULES J N o SINGLE PHASE 300W, 273.4W PTC 00 o'n � 2 U � UTILITY SERVICE LG300N1 K-G4 > Y w co cn co Q (10) ENPHASE M250 > o > W W amzaww (1) AC DISCONNECT MICROINVERTERS W J j a W W > W W W 30A, 240V, 2P, NEMA 3R 250W, 48Vmp # REVISION DATE 0 Original 6/6/16 FUSIBLE JUNCTION BOX(S)B 120% RULE EATON DG221 NRB NEMA 3R CUPERTINO - D - (MSP): MAINS RATING = 100A (2 ) 15A FUSES R� Building Department E - — 100A * 1.2 = 120 AMPS ALLOWABLE TOTAL OF BREAKERS FEEDING BUS BAR = 120A �----, JUN 0 ? 2016 JOB #:13774066 120% OF BUS NOT EXCEEDED (NEC 705.12(D)(2)) DESIGN: RDELGADO REVIEWED FOR CODE COMPLIANCE PAGE: LINE DIAGRAM PAGE NUMBER GEC BONDED DIRECTLY TO (E) GROUNDING ELECTRODE. Reviewed By:,(�G ALL AVAILABLE ELECTRODES PV04 SHOULD BE USED PER CEC 250.50 REQ. BY NEC 690.17 APPLY TO: DISCONNECTS PV LOAD CENTERS COMBINER BOXES REQ. BY NEC 2 APPLY TO: MAIN SERVICE PANEL REQ. BY NEC 690.53 3 APPLY TO: INVERTER LABELS REQ. BY NEC 690.5 (CL ---El APPLY TO: INVERTER REQ. BY NEC 690.5 4 5 APPLY TO: PV SYSTEM DISCONNECT REQ. BY NEC 705.12 (D)(7) 6 APPLY TO: PV SYSTEM BREAKER REQ. BY NEC 690.1 4 C 2 7 APPLY TO: AC DISCONNECT REQ. BY NEC 705.1 2 D 4 8 APPLY TO: MAIN SERVICE PANEL REQ. BY CRC R331.7 9 APPLY TO: MAIN SERVICE DISCONNECTS REQ... BY 690.1 3 (B)(2) 10 APPLY TO: DC DISCONNECT REQ. BY NEC 690.31 (E)(3)11 APPLY TO: EXPOSED RACEWAYS, CABLE TRAYS COVERS OR ENCLOSURES OF JUNCTION BOXES W W � C/)Q > W tY 0 a- U U) :2 W C) O p fY � ? C) c';Q� Z ti N 00 N N 00 0 d - J Q J Q' N O c) v WU 10 >a> w CL C) mac) W W � JILLL, W # REVISION DATE PAGE NUMBER LBLS SIGNAGE REQUIREMENPE Building Del 1. RED BACKGROUND 2. WHITE LETTERING R— JUN 3 7 2016 3. MIN. 3/8" LETTER HEIGHT 4. ALL CAPITAL LETTEWSVIEWED FOR CODE COMP 5. ARIAL OR SIMILAR FONTeviewed By: 6. WEATHER RESISTANT MATERIAL, PER UL 969 W W � C/)Q > W tY 0 a- U U) :2 W C) O p fY � ? C) c';Q� Z ti N 00 N N 00 0 d - J Q J Q' N O c) v WU 10 >a> w CL C) mac) W W � JILLL, W # REVISION DATE PAGE NUMBER LBLS 0 CUP RTINO ,F�afin Qepartment C,..7 rt Nt�LIANCE ��"c,-.. ; �' �. i f.': @ 'r' .wt : i =��- :..1 I•..r v `zt _.. f.71- °�° i LG300N1K*G4�. LG's new module, LG NeCINT" 2 Black, adopts Cello o!• ® LG ca AVE c � APPROVED PRODUCT A customer's values beyond efficiency. It features enhanced warranty, durability, performance under real environment, Life`s Good and aesthetic design suitable for roofs. CUP RTINO ,F�afin Qepartment C,..7 rt Nt�LIANCE ��"c,-.. ; �' �. i f.': @ 'r' .wt : i =��- :..1 I•..r v `zt _.. f.71- °�° i LG300N1K*G4�. LG's new module, LG NeCINT" 2 Black, adopts Cello o!• technology. Cello technology replaces 3 busbars with 12 thin wires to enhance power output and reliability. LG NeON 2 Black demonstrates LG's efforts to increaseC ca AVE c � APPROVED PRODUCT A customer's values beyond efficiency. It features enhanced warranty, durability, performance under real environment, Intertek ta4564573 BSEN61215 Pnenoemkraada� and aesthetic design suitable for roofs. Front Load NLIEnhanced Performance Warranty®. High Power Output LG NeONT 2 Black has an enhanced performance a Compared with previous models, the LG NeONnu 2 Black warranty. The annual degradation has fallen from-0.7%/yr has been designed to significantly enhance its output to-0.6%/yr. Even after 25 years, the cell guarantees 2.4%p efficiency, thereby making it efficient even in limited space. more output than the previous LG NeCINT" modules. Aesthetic Roof y O Outstanding Durability WIN", LG NeONT"' 2 Black has been designed with aesthetics $ fps With its newly reinforced frame design, LG has extended in mind; thinner wires that appear all black at a distance. of ag the warranty of the LG NeON""' 2 Black for an additional The product may increase the value of a property with 2 years. Additionally, LG NeONT" 2 Black can endure its modem design. a front load up to 6000 Pa, and a rear toad up to 5400 Pa About LG Electronics Double -Sided Cell Structure The rear ofthe cell used in LG NeCINT"° 2 Blackwill contribute a ! to generation, just like the front; the light beam reflected a from the rear of the module is reabsorbed to generate a great amount of additional power. LG Electronics is a global player who has been committed to expanding its capacity, based on solar energy business as its future growth engine We embarked on a solar energy source research program in 1985, supported by LG Gmup's rich experience in semi -conductor, LCD, chemistry, and materials industry We successfully released the first Mono XO series to the market in 2010, which were exported to 32 countries in the following 2 years, thereafter. In 2013, LG NeON- (previously known as Mono Xe NeON) won `Intersolar Award; which proved LG is the leader of innovation in the industry. LG Ne®N_2Block Mechanical Properties Celts 6 x 10 Cell Vendor LG LMO= K -G4 Cell Type o!• Better Performance on a Sunny Day 156.75 x 156.75 mm / 6 inches "® ® LG NeCINT" 2 Black now performs better on sunny days Dimensions (L x W x H) thanks to its improved temperature coefficiency. About LG Electronics Double -Sided Cell Structure The rear ofthe cell used in LG NeCINT"° 2 Blackwill contribute a ! to generation, just like the front; the light beam reflected a from the rear of the module is reabsorbed to generate a great amount of additional power. LG Electronics is a global player who has been committed to expanding its capacity, based on solar energy business as its future growth engine We embarked on a solar energy source research program in 1985, supported by LG Gmup's rich experience in semi -conductor, LCD, chemistry, and materials industry We successfully released the first Mono XO series to the market in 2010, which were exported to 32 countries in the following 2 years, thereafter. In 2013, LG NeON- (previously known as Mono Xe NeON) won `Intersolar Award; which proved LG is the leader of innovation in the industry. LG Ne®N_2Block Mechanical Properties Celts 6 x 10 Cell Vendor LG LMO= K -G4 Cell Type Monocrystalline / N -type Cell Dimensions 156.75 x 156.75 mm / 6 inches 0 of Busbar 12 (Multi Wire Busbar) Dimensions (L x W x H) 1640 x 1000 x 40 mm 64.57 x 39.37 x 1.57 inch Front Load 6000 Pa / 125 psf Rear Load 5400 Pa / 113 psf Weight 17.0 t 0.5 kg / 37.48 t 1.1 lbs Connector Type MC4, MC4 Compatible, IP67 Junction Box IP67 with 3 Bypass Diodes Length of Cables 2 x 1000 mm / 2 x 39.37 inch Glass High Transmission Tempered Glass Frame Anodized Aluminum Certifications and Warranty Certifications IEC 61215, IEC 61730-1/-2 IEC 62716 (AmmoniaTest) IEC 61701 (Satt Mist Corrosion Test) ISO 9001 UL 1703 Electrical Properties (STC *) Module Type 300 W MPP Voltage (Vmpp) 32.5 MPP Current (Impp) 9.26 Open Circuit Voltage (Voc) 39.7 Short Circuit Current (Isc) 9.70 Module Efficiency (%) 18.3 Operating Temperature (°C) -40-+90 Maximum System Voltage (V) 1000 Maximum Series Fuse Rating (A) 20 Power Tolerance (%) 0-+3 ' STC (Standard Test Condition): &radiance 1000 W10, Module Temperature 25'C, AM 1.5 • The nameplate p—,output 4 n ea%ned and determined by LG Etecironirsat its cote and absolute disvetion *The typical change N module effidencyat 200 W/m' in relation to 1000 W/m= is -3.036 Electrical Properties (NOCT*) Module Type 300 W Maximum Power (Pmax) 218 MPP Voltage (Vmpp) 29.5 MPP Current (Impp) 7.38 Open Circuit Voltage (Voc) 36.5 _ Short Circuit Current (Isc) 7.83 - NOCT (Nominal Operating CellTemperatume Irradiance 800 W1m',ambient temperature 20'C, wind speed 1 m!s Module Fire Performance (USA) Type 2 (UL 1703) — Fire Rating (for CANADA) Class C (ULC/ORD C1703) Dimensions (mm/in) Product Warranty 12 years Output Warranty of Pmax Linear warranty* • 1) layear. 98%, 2) After 2nd year. 0.6%p amwat degradation, 3)1316% for 25 years Temperature Characteristics yl� yl NOCT 46 t 3 °C Pmpp -0.38 Y*rC a ax o w" m "z a awm �n smm maim Voc -0.28 %/°C — Isc — 0.03 YeC ,mmrm Characteristic Curves � T"o ----------- ----- y 20 .40 -25 0 Z 50 3 �� North America Solar Business Team (8LG Electronics USA Inc Ufe's Good 1000 Sylvan Ave, Englewood Cliffs, NJ 07632 vnmseM w P_-- TemperaturerCt 90 * The dMance between the center of the mounting/grounding holes Product specifications are subject to change without notice. DS -N2 -60 -K -G -F -EN -50427 Copyright ID 2015 LG Electronic All rights reserved. Contact Ig.solar@lge.com 01/04/2015 www.lgsolarusa.com [Nil -5,1% ff] Innovation for a Better We Enphase® M250 Microinverter // DATA INPUT DATA (DC) M250-60-2LL-S22 Enphase®Microinverters Recommended input power (STC) 210 - 310 W Enph-ase@M-250 Maximum input DC voltage 48V _ Peak power tracking voltage 27 V - 39 V Operating range 16 V - 48 V Min/Max start voltage 22 V / 48 V Max DC short circuit current 15A OUTPUT DATA (AC) @208 VAC @240 VAC Peak output power 250 W 250 Wdl E -1 Rated (continuous) output power 240 W 240 W Nominal output current 1.15 A (A rms at nominal duration) 1.0 A (A rms at nominal duration) f Nominal voltage/range 208 V / 183-229 V 240 V / 211-264 V * Nominal frequency/range 60.0 / 57-61 Hz 60.0[57-61 Hz r* Extended frequency range* 57-62.5 Hz 57-62.5 Hz Power factor >0.95 >0.95 t Maximum units per 20 A branch circuit 24 threephase) 16 (singlephase) Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6cycles EFFICIENCY �9ca1� a CEC weighted efficiency 96.5% a-ta Can$ ding Dep Peak inverter efficiency 96.5% Static MPPT efficiency (weighted; reference EN50530) 99.4% Night time power consumption 65 mW max �4f . L. MECHANICAL DATA Ambient temperature range 40°C to +65°C T-he-Enphase° gvr25O-tViicroinverrterdelivers-inereased-energy- iar-rest-and--reduces-design-and Operating -temperature -range -(internal) -40°C o�85°C r, ie�yed _ _ _ _ _ _ . .__. _ . _ ..__ e� _ - Installation complexity with its all -AC approach. With the M250, the DC circuit is isolated and insulated Dimensions (WxHxD) 171 mm x 173 mm x 30 mm. (without mounting bracket) _. ____ ___ _ .__ __. _______ _ __ _ __ ____ _ ____ . __._ __ -_. __ _ _ . _ _. _ from ground so no Ground Electrode Conductor (GEC) is required for the microinverter. This Weight 2.0 kg further simplifies installation, enhances safety, and saves on labor and materials costs. Cooling Natural convection - No fans Enclosure environmental rating Outdoor - NEMA 6 The Enphase M250 integrates seamlessly with the Engage® Cable, the Envoy® Communications FEATURES Gateway', and Enlighten, Enphase's monitoring and analysis software. Compatibility Compatible with 60 -cell PV modules F Communication Power line - - I Integrated groundThe DC circuit meets the requirements for ungrounded PV arrays in PRODUCTIVE $I P`.E RELIABLE NEC 690.35. Equipment ground is provided in the Engage Cable. No i additional GEC or ground is required. Ground fault protection (GFP) is - Optimized for higher -power - No GEC needed for microinverter - 4th -generation product integrated into the microinverter. modules - No DC design or string calculation - More than 1 million hours of testing Monitoring Free lifetime monitoring via Enlighten software - Maximizes energy production required and millions of units shipped Compliance _ UL1741/IEEE1547 FCC Part 15 Class 13CAN/CSA-C22.2 NO 0-M91, - Minimizes impact of shading, - Easy installation with Engage - Industry-leading warranty, up to 25 0 4 04, and 1071-01 dust, and debris Cable years * Frequency ranges can be extended beyond nominal if required by the utility r enphase° To learn more about Enphase Microinverter technology, enphase- L E N E R G YC US visit enphase.com E N E R G Y 0 2015 Enphase Energy. All rights reserved. All trademarks or brands in this document are registered by their respective owner. MKT -00070 Rev 1.0 Everest Solar Systems Crosshil 48-S CrossRail 48-S is the latest addition to our residential product line. It has been optimized for installations with low to moderate snow loads, and can be used as a more economical solution for these markets. ➢ Cost effective solution for areas with snow loads under 40 psf ➢ 6' spans achieved under 10 psf snow load ➢ UL 2703 Listed System ➢ Available in mill or dark anodized finish ➢ Compatible with existing CrossRail hardware 4� ,�., � d' � w•r 9 Yu �4ar7 �,. yygg ya v.^ a ey„�/ 4baCa®tlCa •tl ! f r r a. New rail connector uses only two bolts! CrossRail 48-S shown with EverFlash roof attachment Everest Solar System . CrossRail 48-S Technical data: Material: corrosion resistant aluminum and stainless steel Engineering: stamped engineering letters available for all solar states Warranty: 12 years Certification: UL 2703 Listed System for bonding and fire 2.028 in [52 mm] 'UPF�� 1NO wilding oepatnp-n' Aug o a 2016 f enl�revefome' 48-5 Rail Connector Z 1.890 in [48 mm] 48-5 Rail Profile 1.535 in ................................ 170 110 KEY 50 130 48-5 150 0101 s 170 Note: Spans based on Exposure Category B. Consult CrossRail Engineering Letters for detailed span ch 8' KEY y Table 1: Rail Selection Chart crossRail 48-s i US110615 Everest Solar Systems, LLC Product images are for illustrative purposes �� �'®` b cE 3809 Ocean Ranch Blvd., Suite 111 VDE (C .STI' j �L7, d— ) ,,,, VpE %,gg�-�CT-�^I�� only. Specifications are subject to change `` u +�!. °°, Oceanside, CA 92056 VDE �CSTIL� without notice. All sales of our products shall be REG:Nr. E524 REG. -Nr. E524 avw� nr P ca+1.760.301.5300 0 �--<ew_ subject to Everest Solar Systems terms and VDE CEIAB (fr) Pass1nnovatior TOV Rheinland VDE Certificate REG: Nr. E524 REG. -Nr. E524 info@everest-solarsystems.com VDE CEIAB conditions, including the exclusive limited Declaration of 2011-128 (fr) -Iso (de) (fr) Pass'Innovatlar TOV Rheinland VDE Certificate warranty set forth therein. Conformity 9001:2008 20150618-03 vwvw.everest-solarsystems.com LASTED Declaration of 2011-128 (fr) -ISO (de) Conformity 9001:2008 20150618-03 Mounting systems for solar technology EVEREST SOLAR SYSTEMS EverFlash 4000367 EverFlash Comp Kit, 10X12" Mil COMP SHINGLE ROOF ATTACHMENT 4000366 I EverFlash Comp Kit, 10X12" Black EverFlash Flashing, 10" x 12" 5/16" Sealing Washer Material: aluminum Material: stainless steel, EPDM insert Finish: mill, dark EverFlash L -Foot and Hardware 5/16" Lag Bolt Material: aluminum Material: stainless steel Finish: mill, dark ctlP ERTILIO GENERAL GUIDELINES t ±wilding Oep8lttnent Always refer to roofing manufacturer's instructions prior to starting work. 2®�� Refer to the American Wood Council's guidelines for Lag pull-out capacities (NDS 2005, Tab ' JUN Q Everest Solar recommends consulting a professional roofer prior to beginning work. COMPLIANCE Installer is responsible for verifying the structural integrity of the roof prior to installation. SEC FOR CODE ASSEMBLY: STEP BY STEP The EverFlash is simple and fast to install. Please contact us for further assistance: SERVICE -HOTLINE + 1760.301.5300 Reviewed BY: ®Locate the rafters and snap horizontal and vertical lines to mark the installation position for each EverFlash flashing. Materials required: Tape measure, string line Drill a pilot hole (1I4" diameter) for the lag bolt. Remove any saw dust and fill the hole with i the roofing manufacturer's recommended sealant. Materials required: Drill 0 Insert the flashing so the top part is under the next row of shingles and pushed far enough up slope to prevent water infiltration through vertical joint in shingles. The leading edge of flashing must butt against upper row of nails to prevent turning when tourqued. Materials required: EverFlash flashing Line up pilot hole with EverFlash flashing hole. Insert the lag bolt through the EPDM bonded washer, the L -Foot, the gasketed hole in the flashing and into the rafter. Torque: The range is between 8.3 - 11.6 Ib -ft depending on the type of wood and time of year. The visual indicator for proper torque is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses. If using an impact wrench to install the fasteners be careful not to over torque the fastener. You may need to stop and use a ratchet to finish the install. ® Install Everest Mounting System (refer to CrossRail 48/80 installation manual) Everest Solar Systems, LLC 3809 Ocean Ranch Blvd., Suite 111 Oceanside, CA 92056 Service -Hotline +1.760.301.5300 info@everest-solarsystems.com www.everest-solarsystems.com ctxrtWhrtd,imi Flprl usi(Dais Pei Ib.'�es e:e frw6ArcTz°imN�� #kad'�"m¢are Ell S.I. arts malt A'.ti"u ktle_,q lMeaBm:¢dnvstary Gu?E?����nt ���" =�aull�lr►g Departm Engage Cable System and Accessories Y - Enphase® Engage Cable System // DATA 7�� 1 DE COMPLIA�`10E REV v: Com° Enh E C b l CABLE TYPES /ORDERING OPTIONS - Voltage Connector Spacing PV Module Orientation Model Number #Connectors` Weight`* ase° n a e a e p g g 240 VAC, 4 conductors 1.025 meter (40") Portrait ET10-240-40 40 40 lbs 240 VAC, 4 conductors 1.7 meter (67") Landscape ET17-240-40 40 45 lbs !` �a►� rt_. _ 208 VAC, 5 conductors 1.025 meter (40") Portrait ET10-208-30 30 lbs 208 VAC„ 5 conductors 1.7 meter (67") Landscape — — --��30 ET17-208-30 30 35, lbs 'additional lengths available through Enphase authorized distributors. —weights are approximate ' CABLE SPECIFICATIONS Description Rating Cable temperature rating 90°C (194°F) wet/dry x _ Cable insulatorrating THWN-2 UV exposure rating UL 746 C, F1 t Conductor,size 12, AWG Compliance IEC 60529 IP67, CAN/CSA 22.2 No. 21, 182.3, UL 486A/B, 514C, 6703, and 9703 Cable rating TC -ER Cable Diameter 240 VAC: 10.75mm (0.425") e -- 208 VAC: 11.75mm (0.463") Minimum bend radius 12 cm (4 75) ENGAGE ACCESSORIES The EngageTm Cable is a continuous length of 12AWG cable with pre-installed connectors for Enphase Microinverters. The cable is handled like standard outdoor -rated electrical wire, allowing it to be cut, spliced and extended as needed. Branch Terminator One terminator needed per branch circuit Disconnect Tool Plan to use at least one per, installation The Engage Accessories complement the Engage Cable and give it the ability to adapt to any ET -TERM -10 (sold in packs of 10) ET -DISC -05 (sold in packs of 5) installation. Watertight Sealing Cap Cable Clip One needed to cover each unused ' Many needed to fasten cabling FAST FLEXIBLE SAFE connector on the cabling ET -SEAL -10 (sold in packs of 10) to the racking or to secure looped cabling - Quick installation - Simple design - No high voltage DC ET -CLIP -100 (sold in packs of 100) - Large branch capacity - No additional cables - Reduced fire risk Engage Coupler Used for splicing two power cables within an array ET-SPLK-05 (sold in packs of 5) �] en Kase- E N E R G Y C US To learn more about Enphase Microinverter technology, visit enphase.com r, 1 enphaseg I 1 E N E R G Y © 2014 Enphase Energy. All rights reserved. Al trademarks or brands in this document are registered by their respective owner. SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION UPISERTINO 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 C (408) 777-3228 - FAX (408) 777-3333 -Lild—in-oLokuperlinq.or-tI Pernift No. a - � 1 G7 Den Ave, #of Alarms Smoke: Carbon Monoxide. Address PIE11ART CANNOT BE FINALE D AND CO1MFLE`rr1D UNTIL TtIIS CERTIFICATE 11AS BEEN DIVISION T"El Bu� &UNM A1�1) REJURNLM TO PURPOSE This. affidavit is a self -certification for the installation of all required Smoke and Carbon Mono)dde-A-larms for compliance with 2013 CRC Section R314,2013 CBC Sections and 907.2.11,12 Avhere no interior access for inspections,are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be pravided with Smoke Alarms and Carbon Monoxide Alarms. When the valuation of addition,-,, Alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section 8314 And CBC Sections 907.2.11.5 and 420.6 require that Smoke. Alarms and/or Carbon Monoxide Alarms be installed in the following locations' AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the X X bedroora(s) _2rt_(,N el of a divelling LtL± inc ing basements X ��ry- level X Within each slecjj ng room X Carbon Monoxide Alarms Are not required in dwellings which d6 not contain fuel -burning appliances and that do nothavean Attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with C13C Section 420.6 and shall be approved by the Office of the -State Fire Marshal, Power Supply: In dwc1ling -units with no commercial power supply, alarm(s) may be solely battery operated. Inexist existing dwelling units, alarins are permitted to be solely battery operated where repairs or -alterations do not Testitt in thezeinoval of wall and ceiliirg finislies or there is no access by means of -,-tttic, base rLent car cravtiyl space. Refer to CRC Section R314 And CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for l alarms wih1ci -tiiiiistbeconnected to -the building A?iring. - As owner of th-e above-refereneed property, I hereby certify that the alarm(s) referenced above has/have been installed in accordanco'kvith the manufacturer's instructions and in compliance, with the California Building. acidCalifornia Residential, Codes. The alatjijs have been tested and are operational, as of the date signed below. Sjjro4-�e aild COfarnuloc redsed 03/18114 Owner Name WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATEOF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 (408)777-$228 - ZI Address De W) VI:�e"l-"A'z L 1. Is your real property a registered historical site? El Yes Civil Cade Sections 1101.1 through 1101.8 do nota y. Skip (lie rest of the forniand sign bottom of forin. -2 V,ErNo Go to Question . PI)l 2. Does your real propertyliave a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installationof water-consming plumbing fixtures isnot technically feasible'? 11 Yes Civil Code Sections 1101.1 through 1101.8 do not apply. 0 The licensed plumber's certification has been provided to .the Building Division. Skip the rest of the form andsign bottom of forin. No Go t0Q.iiestion3. I Is water ser vice disconnected for your building? D Yes Civil Code Sections 1101.1 through 1101.8 do not apply.. Skip the test of the forni and sign bottom of form. VPI`�Jo Go to Question 4. 4. Is your real property built and available- for use or occupancy on or before Januaq/ 1, 1994? 0 No My real property is built and available for use or occupancyq January 1;;1994 Civil Code Sections 11.01.1 through 1101.8 do not apply. Skip the rest of the forni and sign bottoin of fbnii,/-' veYes My real property, is built and available for use or occupancy on or before January 1,1914. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and Sign bottom of form.. 5. Please check ONE of the following: vo'mypropertyis, a-singk-fewdly residenflalreal property.. See Civil Code. Section 1101.4, On'a'nd after January 1, 2014, building alterations or improvements sliall requi I re. all non-compliant plumbing fixtures to be replaced With water -conserving plumbing fixtures throughout the building. Oil or before January 1, 2017, all non- compliant plumbing fixtures Shall be replaced with water -conserving plumbing, umbing, fixtures (regardless of whether property undergoes alterations or finprovenients). D Mypropertyis a property, See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements sliall fequire non-,66inpliant plumbing fixtures to be replaced with -water-conserving plumbing. fixtures. On or before January 1, 2019, all 11011 -compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations, or improvements). - Cl';My prol)ertyisieoiiiiiiel-c,ialreal property, Sed Civil Code Section 11OLS. Ch1 and after January 1, 2014,, specified building a , Iterations- our improvements sliall require cion- coirypliant plumbing fixtures to be replaced witli-\vitfr-conservingpitiinbling fixtures: On or -before .January 1, '2019, all non7eppipliant plumbing fixtures shall be replaced with water- -conserving plumbing fixtures ,throu g-hout the building (regardless of whether property, undergoes alterations or improvements). Li,sthe oNviierorowner's agentof thisproperty, certify tinder penalty ofperjury tI.iatiioii-c.oi-npiiiii.tpluiii.bitigfixftires will be replaced prior to date specified above with water -conserving plunibing fixtures in.accordance. with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and Califorilia'Green Building Standards Code, and manufacturer's installation requirements, and that the water-ediiseeving plumbing fixtures comply with the requirements as indicated ti the (,able on the following page. Owner or OwnO.r Agent's Signature: Date: 6 11 14 Upon completing and signing this Certificate, please'rJeturn it to tate Building Division in order to final your building permit. , Z4072015. doe i-evised 08126115