B-2016-1758
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2016-1758 20688 SHELLY DR CUPERTINO, CA 95014-2924 (359 15 002) SANTA CRUZ WESTSIDE ELECTRIC INC SANTA CRUZ, CA 95060 OWNER'S NAME: HUI BEN K AND ANGELA H DATE ISSUED: 04/13/2016 OWNER'S PHONE: 408-966-6351 PHONE NO: (831) 469-8888 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class C-10 Lic. #846294 Contractor SANTA CRUZ WESTSIDE ELECTRIC INC Date 04/30/2017 X BLDG —ELECT —PLUMB MECH X RESIDENTIAL COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing _ _ with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: INSTALL (N) PV SOLAR ARRAY SYSTEM - 5AKW AND 18 I hereby affirm under penalty of perjury one of the following two declarations: MODULES 1. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this Sq. Ft Floor Area: Valuation: $18900.00 permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances APN Number: Occupancy Type: and state laws relating to building construction, and hereby authorize 359 15 002 representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally, the applicant understands and will comply with all non -point source regulations per th Cupertino Municipal Code, Section 9.18. 180 DAYS FROM LAST CALLED I SPECTION. r Signs re Date 4/13/2016 Issued by: Alex Vallelunea Date: 04/13/2016 OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the RE -ROOFS: following two reasons: All roofs shall be inspected prior to any roofing material being installed. If a roof is 1. 1, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Sec.7044, Business & Professions Code) 2. 1, as owner of the property, am exclusively contracting with licensed Signature of Applicant: contractors to construct the project (Sec.7044, Business & Professions Code). Date: 4/13/2016 1 hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1. 1 have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code, for the performance of the work for which this California Health & Safety Code, Sections 25505, 25S33, and 25534. I will permit is issued. maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the s. I certify that in the performance of the work for which this permit is issued, I Health & Safety Code, Section 25532(a) should I store or handle hazardous shall not employ any person in any manner so as to become subject to the material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If, after making this certificate of will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and exemption, I become subject to the Worker's Compensation provisions of the the Health & Safety Code a ions �505, 25533, and 25534. Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. f•) .nt f or att&; sP iced' ager1t;: APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is CONSTRUCTION LENDING AGENCY correct. I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agency for the performance relating to building construction, and hereby authorize representatives of this city of work's for which this permit is issued (Sec. 3097, Civ C.) to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code, Section 9.18. 1 understand my plans shall be used as public records. Licensed Signature Date 4/13/2016 C;UP.ERTINO ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building (�cupertino. org AE PROJECT ADDRESS 4PN# 20688 SHELLY DR OWNERNAME BEN HUI PHONE 408 966-6351 E-MAIL STREET ADDRES k688 Shell Drive CITY, STATE, ZIP Cu etno 95014 7 FAX CONTACT NAME Kristi Cassetta PHONE 831-226-9363 E kcassetta@sandbarsc.com STREET ADDRESS 2119 Delaware Avenue CITY, STATE, ZIP Santa Cruz Ca 95060 FAX 831-515-5098 ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT IX CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS. LIC # Sandbar 846294 C-10 `9ana erAum Westside Electric dba Sandbar E kcassetta sandbarsc.com FAX 831-515-5098 STREET ADDRESS 2119 Delaware Avenue CI Y, STATE, ZIP Santa Cruz Ca 95060 PHONE 831-469-8888 ARCHITECT/ENGINEER NAME Sun evit LICENSE NUMBER BUS. LIC # COMPANYNAME E-MAII Sam - sholing@sungevity.com FAX STREET ADDRESS Franklin Street Ste. 310 CITY, CITY,STAT�akland CA 94607 ZIP PHONE USE OF SFD or Duplex ❑ Multi -Family PROJECT IN AMDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes NO FLOOD ZONE ❑ Yes ❑ No IX SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: KILOWATTS (COMMERCIAL ONLY): TOTAL VALUATION: $18, 900 DESCRIPTION OF WORK t Installation of a 5.4kw grid tied photovoltiac solar array roof mount [ RECEIVED BY, ,°,, By my signature below, I certify to each of the follow I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is orrect I have Teathe Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building c ns do . I r' a representatives of Cupertino to enter the above -identified property for inspection purposes. Signature of Applicant/Agent: Date: 4/13/16 SUPPL9MrNTAL MtOJkMATION REQUIRED o> FicE usE 01NLY OVER-Tl )± gql INTER F" ❑ EXPRESS • -� . �, STANDARD PHOTOVOLTAIC- SYSTEM SYSTEM SIZE: AC / DC kW STC EQUIPMENT: A PV MODULES: INVERTER(S): SCOPE OF WORK: 4.717kW \ 5.4kW (18) LG LG30ON1 K-G4 (1) ABB PVI-4.2-OUTD-S-US-A INSTALLATION OF A SAFE AND CODE -COMPLIANT GRID -TIED SOLAR PV SYSTEM ON AN EXISTING RESIDENTIAL ROOF TOP. 0 1 1 OFFICE C `Py-' FLOTPJANS CHECKED BY DATE V4113 NAP C PLANNING DEPT CUPERTINO sunGEVITY' GENERATE POSITIVE- DRIVEWAY I SHELLY DR UMI`IIUPJITY DEVELOPMENT D RTNIENT BUILDING GIV!S!ON - CUPER O This set of \asp3cifications MUST\kep.,.job sit; d�icn. It is unlavijfuchangns on Sarre,, or t The strr.1pinci of this planand specifications SHALL NOT bo- i s yid to permit or to be an aNproval of the violation of any provision f any 'it, 0 F State Law. BY DATE PERMIT NO. (� ^ l ii— A rj 0 SITE PLAN N SCALE: N.T.S. 4 I RECEIVED' BY CUPERTINO Building Deparb-nern API ! 2 20 IEVVED FOR CODE COMPLIANCE Reviewed By: ROOF MOUNTED CONDUIT ----ram I I I Z Q SERVICE DROP 5 SHEET INDEX PV0.0 COVER AND SITE=PLAN PV1.0 GENERAL NOTES PV2.0 ARRAY LAYOUT PV3.0 LINE DIAGRAM PV4.0 LABELS KEY: ---- PROPERTY LINE ' — — — CONDUIT RUN INVERTER DRIVEWAY Ea SUBPANEL FENCE Q DC DISCONNECT FIRE CLEARANCE ao AC DISCONNECT STRUCTURAL UPGRADES JUNCTION BOX SOLAR MODULE 0 MONITORING UNIT ^^� MAIN SERVICE PANEL °a COMBINER BOX 0 UTILITY METER ROOF 0 PV METER OBSTRUCTION APPLICABLE CODES: 2013 CEC (BASED ON 2011 NEC) 2013 CBC 2013 CRC 2013 CPC 2013 CMC 2013 CFC LOCAL AMENDMENTS TO CA CODES CONTRACTOR INFORMATION: SANDBAR SAN JOSE 2119 DELAWARE AVE SANTA CRUZ, CA 95060 JURISDICTIONAL INFORMATION: CUPERTINO, CITY OF 10300 TORRE AVENUE CUPERTINO, CA 95014 NOTES TO INSTALLER: QUAD (E) QO BREAKERS IN MSP TO LAND SOLAR IN MSP FARTHEST AWAY FROM MAIN BREAKER. POST INSTALL SUNEYES REQUIRED? NO I CERTIFY THAT NO CHANGES HAVE BEEN MADE TO THE ARRAY LAYOUT: CUSTOMER INFORMATION: BEN HUI 20688 SHELLY DR CUPERTINO, CA 95014 (408) 966-6351 / #2567969 DESIGNED BY: REV #: DATE: Suraj.N 0 1 4/11/16 PV- 0.0 THESE DRAWINGS, SPECIFICATIONS, AND DESIGNS ARE THE PROPERTY OF SUNGEVITY INC. NO PART SHALL BE COPIED OR USED FOR OR WITH ANY OTHER WORK OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSENT A I♦ 11 SUNGEVITY INC. 66 FRANKLIN ST SUITE 310 OAKLAND, CA 94607 By: JJAFFE Date:4/11/16 Location: Hui - 2567969 SW Sheet Size: 11 x17 -GENERAL NOTES ELECTRICAL NOTES. GENERAL NOTES: E1. ALL EQUIPMENT IS LISTED FOR USE. N1. DRAWINGS ARE DIAGRAMMATIC ONLY. THE LOCATION AND ROUTING OF RACEWAYS SHALL BE DETERMINED BY THE CONTRACTOR UNLESS OTHERWISE NOTED OR STANDARDIZED. N2. ALL EQUATIONS ACCOUNT FOR WORST CASE CONDITIONS. A N3. IF A DISCREPANCY IN QUANTITY OR SIZE OF CONDUIT, WIRE, EQUIPMENT DEVICES, OVERCURRENT PROTECTION, GROUNDING SYSTEMS, ETC. (ALL EQUIPMENT AND MATERIALS) THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INFT Ldi! ALL MATERIALS AND SERVICES REQUIRED BY THE STRICTEST CONSDI i iONS IN THE SPECIFICATIONS OR NOTED ON THE PLANS TO ENsuRE COMPLETE COMPLIANCE WITH ALL CODFS .AND TO ENSURE TN;C LONGEVIT'y AND SAFETY OF THE OPERABLE SYSTEM. N4. ALL OUTDOOR EQUIPMENT SHALL BE MIN. NEMA 311 RATED. N5. METAL CONDUIT AND ENCLOSURES SHALL BE USED WHERE PV SOURCE OR OUTPUT CIRCUITS ARE RUN INSIDE A BUILDING. N6. MODULES SHALL NOT BE PLACED OVER ANY PLUMBING VENTS AND AT LEAST 6" ABOVE FLUSH VENTS. N7. THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ANY AND ALL REQUIREMENTS GIVEN BY UTILITY COMPANIES. N8. FOR ADDITIONAL EQUIPMENT SPECIFICATIONS, SEE PROVIDED CUT SHEETS. N9. ALL LABELS AND MARKINGS SHALL BE ATTACHED ACCORDING TO REQUIREMENTS BY NEC AND THE LOCAL AHJ. THE AHJ MAY HAVE SPECIAL LABEL REQUIREMENTS BEYOND THE B SCOPE OF THIS DOCUMENT. THIS MAY ENCOMPASS LANGUAGE INCLUDING, BUT NOT LIMITED TO, THAT FOUND IN NEC ARTICLES 690.5 (C), 690.14 (C)(2), 690.17, 690.53,690.35(F), 690.54, 690.64(B)(7) and 705.10 N10. INSTALLER TO FOLLOW ALL LOCAL JURISDICTION GUIDELINES. N11. ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEC REFERENCES. N12. IT IS ILLEGAL FOR ANYONE UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFFESIONAL ENGINEER OR REGISTERED ARCHITECT TO ALTER ANY ITEMS ON THIS PLAN. N13. THE ENGINEER HAS NOT BEEN RETAINED FOR JOB SUPERVISION. N.14 ALL OSHA REGULATIONS AND STANDARDS FOR SAFE AND HEALTHFUL WORKING CONDITIONS TO BE FOLLOWED. N.15 ALL CONTRACTORS WORKING ON ROOFS TO BE INSURED AS SUCH. STRUCTURAL NOTES: S1. MOUNTS ARE DIAGRAMMATIC AND EXACT LOCATION MAY CHANGE, BUT SHALL BE ACCURATELY SPACED. C S2. MOUNTS SHALL BE STAGGERED WHEN NECESSARY TO EVENLY DISTRIBUTE LOAD AMONGST RAFTERS. S3. DO NOT SPLICE RAILS IN MIDDLE 50% OF SPAN BETWEEN TWO MOUNTS. E2. MAXIMUM VOLTAGE DOES NOT EXCEED 600VDC. E3. ANY EQUIPMENT OR ELECTRICAL MATERIALS USED FOR THIS INSTALLATION SHALL BE NEW AND LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY. E4. AN INVERTER IN AN INTERACTIVE SOLAR PV SYSTEM SHALL AUTOMATICALLY DE -ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMIAM IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED. E5. ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION. E6. ANY AC COMPONENT SHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENT CALCULATED AT THAT COMPONENT. E7. ALL MODULES AND. ANY RELATED ROOF MOUNTED METALLIC EQUIPMENT SHALL BE PROPERLY GROUNDED. E8. DC EQUIPMENT SHALL BE 60OVDC RATED MINIMUM. E9. MARKINGS SHALL BE PROVIDED TO INDICATE THAT ALL CONTACTS OF THE DISCONNECT EQUIPMENT MIGHT BE ENERGIZED. E10. CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OR JUNCTION BOXES/COMBINER BOXES PER APPROPRIATE JURISDICTIONAL REQUIREMENTS. E11. FOR ANY UNGROUNDED PV SYSTEM, A LABEL READING: "WARNING - ELECTRICAL SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED." SHALL BE PLACED AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE. E12. INVERTER(S) SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION DEVICE. E13. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. E14. THE POINT OF CONNECTION COMPLIES WITH APPLICABLE CEC/NEC. E15. BACKFED SOLAR BREAKER(S) SHALL BE INSTALLED ATTHE OPPOSITE END OF THE CIRCUIT OR FURTHEST AWAY FROM THE MAIN BREAKER. E16. ALL WIRE, VOLTAGES, AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TO TEMPERATURE DERATING AND LOCATION. E17. ONLY COPPER (CU) CONDUCTORS SHALL BE USED. CONDUCTORS SHALL BE STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS. E18. DISCONNECT SHALL BE WIRED SO NO BLADES ARE ENERGIZED E19. ALL MODULES AND RACKING SHALL BE GROUNDED VIA IRON RIDGE RAIL INTEGRATED GROUNDING (PLEASE SEE DATA SHEET) OR WITH TIN PLATED DIRECT BURIAL RATED LAY IN LUGS USING STAINLESS STEEL HARDWARE, STAR WASHERS, AND THREAD FORMING BOLTS. E20. ALL EQUIPMENT SHALL BE GROUNDED, INCLUDING BONDING JUMPERS WHERE NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDIVIDUAL PIECES OF RAIL. gs� , ,7q �,-� I��{p ttty+++,,,q,Ip� p�pp C U E 11 1 9 iT �7 O.! Building Depoment t 2j1, REVIEWED FOR CODE COMPLIANCE Reviewed By. CUSTOMER INFORMATION: BEN HUI 20688 SHELLY DR CUPERTINO, CA 95014 (408) 966-6351 / #2567969 0 1 C sunGEVITY° GENERATE POSITIVE' DESIGNED BY: IREVU DATE: PV-1.0 Suraj.N 1 0 1 4/4/16 SUNGEVITY INC. 66 FRANKLIN ST SUITE 310 OAKLAND, CA 94607 By: SURAJ.NAIR Date:- Location: Hui - 2567969 SV1 Sheet Size: 1 1x1 7 THESE DRAWINGS, SPECIFICATIONS, AND DESIGNS ARE THE PROPERTY OF SUNGEVITY INC. NO PART SHALL BE COPIED OR USED FOR OR WITH ANY OTHER WORK OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSENT --: -- - _- _- - - -- - - - - - - - - _ - -- - -- (18) LG LG300N1 K G4 - -- -- - - -- — -- - ----- --- ---------- MODULE WEIGHT: 37.48 - - -- ---- - ------ MODULE LENGTH: _ - _ - . - 64.57 MODULE WIDTH: 39.37 - 3' 42'-4" 4,_2„ ROOF 1 SPECS RAFTER SIZE: 2X6 NOMINAL RAFTER SPAN: 7' - 2" RAFTER SPACING: 24" ROOF MATERIAL: COMPOSITE SHINGLE I I I I I I I I I I I I I I I O I I I I I I I I ARRAY 1 SPECS NUMBER OF MODULES: 18 A I I I I TOTAL MOD. WEIGHT (Ibs): 674.6 A RACKING WEIGHT (Ibs): 90.8 T I ( I I I I I I I I I I I I I ARRAY WEIGHT (Ibs): 765.5 ARRAY AREA (sgft): 317.8 I T 1 I ! I I I I i I I I i I � I ! 1 �II�•r• �I-- :.. I" ARRAY DEAD LOAD (Ibs/sgft): 2.4 - NUMBER OF MOUNTS: 32 I II LOAD PER MOUNT(I.bs): 23.9 c° --� AZIMUTH( 180 H ARRAY TILT(') 20 NUMBER -OF FLOORS 2ARRAY 11 C NOTE: MODULES SHALL NOT BE GREATER INCHES ABOVE ROOF COVERING 4e sunGEVITY° GENERATE POSITIVE` SOLAR MOD IRONRIDGE X L-F( QMSE-LAG SHIN, COMPOSITE SHIN, 5" X 5/16" - 1 2.5" MIN. EMBEDMENT[ SCF 2X6 NOMINAL, 24 1... . . IWIOUNTING ®ETf41L 2 SCALE : NTS � RRAY L�►YOU� SERVICE DROP �r55' ,� rcfig wilding Depatmenl -170 C''OidiPL iAr�cE REV1E`�GD FOR CaDE RPvle�ed 8��. ROOF SECTION SYMBOL KEY: ------- RAIL — — — — RAFTERS ROOF FIRE CLEARANCE ®.............(2) STRING CONFIG. I STRUCTURAL UPGRADES SOLAR MODULE ® MOUNT ® SKYLIGHT ® CHIMNEY c PLUMBING OR ATTIC VENT ED ATTIC VENT CUSTOMER INFORMATION: BEN HUI 20688 SHELLY DR CUPERTINO, CA 95014 (408) 966-6351 / #2567969 DESIGNED BY: IREV #: DATE: PV- 2.0 Suraj.N 0 4/4/16 By: SURAJ.NAIR Date:— Locabon: Hui - 2567969 SV1 Sheet Size: 11x17 THESE DRAWINGS, SPECIFICATIONS, AND DESIGNS ARE THE PROPERTY OF SUNGEVITY INC. NO PART SHALL BE COPIED OR USED FOR OR WITH ANY OTHER WORK OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSENT C 91 SUNGEVITY INC. 66 FRANKLIN ST SUITE 310 OAKLAND, CA 94607 - - - -ELECfRtCAtKEY..-�-- --= --- _,.- --- -- - - - --- -- _--•-.- �.--.-.�..... - ---- -- ----- - - --- - - -- -- MODULE -ELECTRICAL -SPECIFICATIONS- - - - - - - - -- _-.------ _ -_-•�_..------�---_ `_ - - ---- - ---- - - -- -- -- - - -- - -- - - - S):LG LG300N1K G4- �. - -- -���-- --BREAKER --- ----- - - - -- --- ---• =- - --- - - -- SHORT CIRCUIT CURRENT (Isc): 9.7 --'r=-SWITCH - - - -- - :_ - - -- --- - - - - -- - - -_ -- - - - - - - - ----_ - ---- OPEN CIRCUIT VOLTAGE (Vo -� - - - ---- 39 7 - - - 0 SCREW TERMINAL - - _. ---_: = - _-_ _ _ _ -- OPERATING CURRENT (IMP): - - 9.26 - FUSE OPERATING VOLTAGE (VMP): 32.5 • SPLICE MAX SERIES FUSE RATING: 20 EARTH GROUND STC RATING: 300 ril CHASSIS GROUND PTC RATING: 273 - - - GEC DESIGN CONDITIONS EGC HIGHEST 2% DB DESIGN TEMP (°C): 32 A V C (4) #10 PV-Wire (1) #10 EGC FREE AIR 1 STRING OF 9 MODULES 1 STRING OF 9 MODULES (4) #10 THWN-2 (1) #10 EGC 1/2" EMT (IF APPLICABLE) MIN. NEMA3R UL LISTED JUNCTION BOX WITH 90'C TERMINAL RATINGS LOCATED ON ROOF (3) #10 THWN-2 (3) #10 THWN-2 (1) #8 GEC (1) #8 GEC 1/2" EMT 1/2" EMT (N) PVI-4.2-OUTD-S-US-A INVERTER W/ INTEGRATED DC DISCONNECTS MPPT 1 AC DC .. OUTPUT -- - - - - - - GEC --- --- MPPT 2 INVERTER MAX Voc = 9 x [39.7V + (39.7V x-0.0028 x (0°C - 25°C))] = 382.5VDC Imax = 9.7A x 1. STRING x 1.25 = 12.125A 150x1.2=180 180 - 1.50(MCB) = 30A MAX ALLOWABLE AC PV BREAKER = 30A sunGEVITY' GENERATE POSITIVE- SUNGEVITY INC. 66 FRANKLIN ST SUITE 310 OAKLAND, CA 94607 By: JJAFFE Date:4111/16 Location: Hui - 2567969 SV1 Sheet Size: 11x17 LOCUS METER .-_T -. CONDUIT ELEVATION: 1/2 TO 3-1/2" = 22 °C HIGH AMBIENT TEMPERATURE: 32 °C EXTREME LOW: 0°C ROOFTOP AMBIENT TEMP (Tcorr): 54°C = 0.76 CONDUIT FILL (Cfill): 0.8 CONTINUOUS USE = Imax * 1.25 = 15.16A CONDITIONS OF USE = Imax / Tcorr / Cfill = 12.1 A/0.76/0.8 = 19.90A ' 150A MAIN BREAKER METER (E) LOADS r1 (E) LOADS (E) 150A MSP 25A 2P 240V 2P 3-W 1(D MIN. MEAN EXTREME ANNUAL DB ('C): 0 A INVERTER 1 SPECIFICATIONS ABB PVI-4.2-OUTD-S-US-A -_ RATED WATTS (EACH): 4600 AC OPERATING VOLTAGE (V): 240 AC OPERATING CURRENT (A): 20 NUMBER OF MPPT CHANNELS 2 INVERTER EFFICIENCY: 0.96 INTEGRATED DC DISCONNECT INVERTER 1 MPPT 1 SPECIFICATIONS MAXPOWER POINT CURRENT (Imp): 9.3 MAX POWER POINT VOLTAGE (Vmp): 292.5 MAX SYSTEM VOLTAGE (Voc): 382.5 SOURCE CIRCUIT CURRENT (Isc): 12.1 MAX SHORT CIRCUIT CURRENT (Isc): 12.1 INVERTER 1 MPPT 2 SPECIFICATIONS MAXPOWER POINT CURRENT (Imp): 9.3 MAX POWER POINT VOLTAGE (Vmp): 292.5 MAX SYSTEM VOLTAGE (Voc): 382.5 SOURCE CIRCUIT CURRENT (Isc): 12.1 MAX SHORT CIRCUIT CURRENT (Isc): 12.1 I I GEC IRREVERSIBLY SPLICED TO EXISTING GEC OR BONDED DIRECTLY TO EXISTING GROUNDING ELECTRODE Od' P E tl 6 I I 1 d V '4 j R; I(,j; Building Department >- fff REVIEWED FOR CODE COMPLIANCE Reviewed By: 18 MODULES TOTAL 18 x 273(PTC WATTS) x 0.96 = 4717 CEC WATTS PVI-4.2-OUTD-S-US-A MAX OUTPUT CURRENT = 20A BREAKER SIZE = 20A x 1.25 = 25A => 25A CUSTOMER INFORMATION: BEN HUI 20688 SHELLY DR CUPERTINO, CA 95014 (408) 966-6351 / #2567969 CONDUCTOR SIZE FOR 19.90A DESIGNED BY: IREV #:I DATE: INSTALLATION SHALL USE MIN. #10 AWG Suraj.N 1 0 4/11/16 PV- 3.0 THESE DRAWINGS, SPECIFICATIONS, AND DESIGNS ARE THE PROPERTY OF SUNGEVITY INC. NO PART SHALL BE COPIED OR USED FOR OR WITH ANY OTHER WORK OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSENT L -- - - - — — -- -- — - -- - - Lt NEG_690.5(c) __ _-__ . _ _ __==_-NEC 690.31 (E) 3_&`4:;`2012IFC 605.11.1 --� - — ✓ _ _ _- - - - INTERACTIVE PHOTOVOLTAICPOWERSOURCE. _: -_ --- - -- PLACETHIS LABEL ON_INVERTER(S) OR_NEAR_=- .- PLACE ON ALL JUNCTION BOXES, EXPOSED GROUND -FAULT INDICATOR (ON INVERTER(S) U.O.N.) RACEWAYS EVERY 10' AND=-1' FROM BENDS - - _ _ ENT (A): 20 - — RATED AC OUTPUT CURR - AND PENETRATIONS, ADJACENT TO THE NOMINAL OPERATING AC VOLTAGE (V): 240 MAIN SERVICE DISCONNECT WARNING A _ - -A ----- - - ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY RE UN-GRCUNIDED AND ENERGIZED NEC 690.17(E) PLACE THIS LABEL ON ALL DISCONNECTING MEANS 1A/HP:PF FNFRr,17r=n IN AN nPFN P0.glTICIN WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION NEC 705.12(D)(2)(b) B PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL AND SUBPANEL IF APPLICABLE)) C WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE NEC 705.12(D)(3) PLACE LABEL ON ALL EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES. CAUTION CONTAINS MULTIPLE POWER SOURCES sunGEVITY° GENERATE POSITIVE' SUNGEVITY INC. 66 FRANKLIN ST SUITE 310 OAKLAND, CA W07 WARNING PHOTOVOLTAIC POWER SOURCE NEC 690.35(F) PLACE THIS LABEL AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE: WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED NEC 705.12(D)(2)(c) PLACE LABEL ON ALL EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES. WARNING THIS EQUIPMENT FED BY MULTIPLE POWER SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR INVERTER 1 MPPT 1 DC DISCONNECT PHOTOVOLTAIC SYSTEM DISCONNECT RATED MAX POWER POINT CURRENT (Imp): 9.3 RATED MAX POWER POINT VOLTAGE (Vmp): 292.5 MAX SYSTEM VOLTAGE (Voc): 382.5 SHORT CIRCUIT CURRENT (Isc): 12.1 INVERTER 1 MPPT 2 DC DISCONNECT PHOTOVOLTAIC SYSTEM DISCONNECT RATED MAX POWER POINT CURRENT (Imp): 9.3 RATED MAX POWER POINT VOLTAGE (Vmp): 292.5 MAX SYSTEM VOLTAGE (Voc): 382.5 SHORT CIRCUIT CURRENT (Isc): 12.1 1 -Tjj.A0 -P c'-SLl1�CSln`� DePaftmen GODS Compup NCE FOR Reviewed CUSTOMER INFORMATION: BEN HUI 20688 SHELLY DR NOTE: CUPERTINO, CA 95014 BACKGROUND AND LETTERING COLORS FOR (408) 966-6351 / #2567969 SIGNAGE/LABELS SHALL COMPLY WITH (IN ORDER OF PRIORITY) AHJ & FIRE DEPARTMENT AMENDMENTS, STATE CODE, AND ANSI GUIDELINES. THIS PAGE IS DESIGNED BY: REV #: DATE: INTENDED FOR SIGNAGE/LABEL VERBIAGE ONLY. PV- 4.0 . Suraj.N 0 4/4/16 By: SURAJ.NAIR Date:— Location: Hui - 2567969 SV1 Sheet Size: t tx17 THESE DRAWINGS, SPECIFICATIONS, AND DESIGNS ARE THE PROPERTY OF SUNGEVITY INC. NO PART SHALL BE COPIED OR USED FOR OR WITH ANY OTHER WORK OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSENT A N C I. i I Q• r 1 LG30QI11TfC=G4. 1 s , Innovation for s gum LG NU a oI= LG's new module, NeONTM 2 Black, adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires APPROVED PRODUCT to enhance power output and reliability. NeONTm 2 Black V 6 0 demonstrates LG's efforts to increase customer's values E 05 °s �-C'11111 C��� beyond efficiency. It features enhanced warranty, durability, Intertek ~�M1 KN1 S64S73 RSEN61215 performance under real environment, and aesthetic design PhotcvoltalcModules suitable for roofs. ® Enhanced Performance Warranty ®® High Power Output LG NeONT" 2 has an enhanced performance warranty. - Compared with previous models, the LG NeONTM 2 The annual degradation has fallen from-0.7%/yr to has been designed to significantly enhance its output -0.6%/yr. Even after 25 years, the cell guarantees 2.4%p efficiency, thereby making it efficient even in limited space. more output than the previous NeONTM modules. Aesthetic Roof O Outstanding Durability LG NeONTM 2 has been designed with aesthetics in mind; With its newly reinforced frame design, LG has extended thinner wires that appear all black at a distance. The the warranty of the NeONTM 2 for an additional 2 years. product may increase the value of a property with its Additionally, LG NeONTM 2 can endure a front load up to modern design. 6000 Pa, and a rear load up to 5400 Pa. ®s Better Performance on a Sunny Day WN Double -Sided Cell Structure ° LG NeONTM 2 now performs better on sunny days thanks The rearof the cell used in LG NEON' 2 will contribute to to its improved temperature coefficiency. generation, just like the front; the light beam reflected from the rear of the module is reabsorbed to generate a great amount of additional power. About LG Electronics LG Electronics is a global player who has been committed to expanding its capacity, based on solar energy business as its future growth engine. We embarked on a solar energy source research program in 1985, supported by LG Groups rich experience in semi -conductor, LCD, chemistry, and materials industry. We successfully released the first Mono X® series to the market in 2010, which were exported to 32 countries in the following 2 years, thereafter. In 2013, NeON'" (previously known as Mono X's NeON) won "Intersolar Award'; which proved LG is the leader of innovation in the industry. Mechanical Properties Cells 6 x 10 Cell Vendor LG Cell Type Monocrystalline / N-type Cell Dimensions 156.75 x 156.75 mm / 6 x 6 inch u of Busbar 12.�Multi Wire Busbar) Dimensions (Lxyyo xrti),I �_ - '.:. '" 1640 x 1000 x 40 mm 64.57 x 39.37 x 1.57 inch Front Load 6000 Pa / 125 psf 0 Rear Load 5400 Pa / 113 psf weight 17.0 ± 0.5 kg / 37.48 ± 1.1 lbs Connector Type MC4, MC4 Compatible, IP67 Junction Box IP67 with 3 Bypass Diodes Length of Cables 2 x 1000 mm / 2 x 39.37 inch Glass High Transmission Tempered Glass Frame Anodized Aluminum Certifications and Warranty Certifications (In Progress) IEC 61215, IEC 61730-1 /-2, UL 1703, - ISO 9001, IEC 62716 (Ammonia Test), IEC 61701(Salt Mist Corrosion Test) Module Fire Performance Type 2 (UL 1703) Product Warranty 12 years Output warranty of Pmax (measurement Tolerance ± 3%) Linear warranty* I * 1) 1 st year 98%, 2) After 2nd year. 0.6%p annual degradation, Temperature Coefficients 3) 83.6%for 25 years NOCT 46 ± 3 °C Pmpp -0.38 %/oC Voc -0.28 %/°C Isc 0.02 %/°C Characteristic Curves 5 1o0ow E 10.00 e.0o eoow 6.00 600W 4.00 40OW zoow volra9� N) _ 0.00 5.00 10.00 1s.00 2000. 25.00 30.00 35.00 40.00 45.o0 40 zo 0 40 -25 0 :5 so 75 90 North America Solar Business Team LG LG Electronics U.S.A. Inc Lifes Good 1000 Sylvan Ave, Englewood Cliffs, NJ 07632 Contact lg.solar@lge.com www.Igsolarusa.com Te peram,e (7e1 Electrical Properties (STC *) 300 W MPP Voltage (Vmpp) 32.5 MPP Current (Impp) 9.26 Open Circuit Voltage (Voc) 39.7 Short Circuit Current (Isc) 9.70 Module Efficiency (%) 18.3 v r v l� i[ v t J I V 1 1 i- Operating Temperature (eC) -40 - 40 Maximum System Voltage (V) 1000 Maximum Series Fuse Rating (A) 20 Power Tolerance (%) 0 - +3 * STC (Standard Test Condition): Iradiance 1000 W/m-' Module Temperature 25 °C, AM 1.5 The nameplate power output is measured and determined by LG Electronics at its sole and absolute discretion. •The typical change in module efficiency at 200 W/m' in relation to 1000 W/m' is -3.091a Electrical Properties (NOCT*) 300 W Maximum Power (Pmpp) 218 MPP Voltage (Vmpp) 29.5 MPP Current (Impp) 7.38 Open Circuit Voltage (Voc) 36.5 Short Circuit Current (Isc) 7.83 * N0CT (Nominal Operating Cell Temperature): Irradiance 800 W/m2, ambient temperature 20 °C, wind speed 1 m/s Dimensions (mm/in) x -.1y -.1 cotes :id.shot side Game `The distance behwen the center of the mounting/grounding holes. Product specifications are subject to change without notice. DS-N2-60-K-G-F-EN-50427 Copyright © 2015 LG Electronics. All rights reserved. Innovation for a Better Life 01/04/2015 —_ ------------= -_ _- ----- - - - - - ------_----- - -- Mec an ca-Inatallation Intertek AUTHORIZATION TO -MARK - - • Four bolts, four nuts, four spring Mounting Methods ur M6 stainless steel r This authorizes the .application of the Certification Mark(s) shown below to the models described in the Products) General Information _. washers; and -eight flatare recommended Covered section when made in accordance with, the conditions set.forth in the Certification Agreement and Listingper solar module. • Select_the_appropriate-oTientaflon tatnaximize Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing _-- - -- •For rear loads 5400Pa, modules should be Re ort. sunlight exposure. p fastened with four M8 stainless steel bolts, four • Module should not be mounted or stored in a way nuts, four spring washers, and eight flat washers. This document is the property of Intertek Testing Services and is not transferable. The certification marks may be that the front/top glass faces downward in order to P P Y 9 () Y • The module may be fastened to a support by using applied only at the -location of the Party Authorized To Apply Mark. prevent water from entering the junction box, which both the outer and inner bolt holes of the frame. could cause a safety hazard. Applicant: LG Electronics Inc. 168, Suchul-daero, Solar Business Division (Solar Factory), Gumi-si, Address: Gyeongsangbuk-do 730-903, Republic of Korea Country: Republic of Korea Contact: Mr. Jeongwon Choi Phone: +82-54-4690386 FAX: +82-54-4607931 Email: jeongwon7.choiQlge.com Manufacturer: LG Electronics Inc. 168, Suchul-daero, Solar Business Division (Solar Factory), Gumi-si, Address: Gyeongsangbuk-do 730-903, Republic of Korea Country: Republic of Korea Contact: Mr. Jeongwon Choi Phone: +82-54-4690386 FAX: +82-54-4607931 Email: jeongwon7.choi@lge.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Intertek Testing Services Shanghai Control Number: 5000343 Authorized by: usUS»v. Intertek Thomas J. Manager • Clearance between the solar module frames and structures such as roofs or ground is required to prevent wiring damage and to allow air to circulate behind the solar module. The recommended standoff height is a minimum of 100mm. • When installed on a roof, the solar module must be mounted over a fire-resistant roof covering rated for the application. The fire resistance of the solar module is class C after ANSI/UL790. • A slope less than 5in/ft is required to maintain a fire class rating. • The solar module is only IEC listed for use when its factory frame is fully intact. • Removal or alteration must be done by an authorized and qualified individual • Creating additional mounting holes may damage the solar module and reduce the strength of the frame. • We recommend a 6mm gap between module frames to avoid tension from thermal expansion. �-_ TIN(DThe fire rating of this module is valid only when �..ry �yw=eNounted in the manner specified in the mechanical i �. building Dep� '+ ,. (� , ,2"01 mounting instructions. t R �� �� The module is considered to be in compliance with 10 � P• �'� UL1703 only when the module in mounted in the L. ,,,�.. This document supersedes all previous Authorizations to Mark for the noted Report Number. l.._-------- _goner specified by the mounting instructions This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client Intertek's responsibility and rtabT�,arre_ t N manner n . 6rnited to the terns and conditions of the agreement_ Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage ocgsionedu E. 0 FOR C O L F- C O M P i i r by the use of this Authorization to Mark. Only the Client is authorized to pen -nit copying or distribution of this Authorim ion to Mark and then only in its entirety. use of Interte's Certification mark is ,he solar module may be mounted by using the restricted to the conditions laid out in the agreement and in this Authorization to Mark- Any further use of the Intertek narna for the sale or advertisement of the tested material, product or service roust- firstbeappnrvedinwritingbylntertek.InitiWFackxyAssessmentsandFollowupServicesareforthepurposeofassuringappropriateusageoftheCertificationrnarkinaccordancewiththe r��:vie�Ned By: following methods: (*Torque:8-12Nm ) agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s)• UL 1703 2002/03/15 Ed:3 Rev:2014/11/18 UL Standard for Safety Rat -Plate Photovoltaic Modules and Panels Product: Crystalline Silicon Photovoltaic modules Brand Name: L Electarownics LGxxxN 1 C-G4 ('xxx' is the number from 280 to 340, in step of 5), LGxxxN1 W-G4 ('xxx' is the number from 280 to 340, in step of 5), Models: LGxxxS1 C-G4 ('xxx' is the number from 250 to 300, in step of 5), LGxxxS1 W-G4 ('xxx' is the number from 250 to 300, in step of 5), LGxxxNIK G4 ('xxx' is the number from 280 to 330, in step of 5). ATM for Report 150201020SHA-001 Page 1 of 1 ATM Issued: 28-Apr-2015 ED 16-3-15 (1,fan-13) Mandatory • When installing modules in heavy snow areas, special care should be taken to install the modules in a manner that provides sufficient design strength while meeting local code requirements. • LG modules (Fire performance: Type 2) shall be mounted with racking and mounting products certified and listed for system fire class rating in accordance with UL1703 edition 2014 and UL2703 edition 2014. • It is recommended to check with local authorities for fire safety guidelines and requirements for any building or structure on to which the panels will be installed. Mounting by using frame bolts holes • Secure the solar module to the structure by using the factory mounting holes. • Each module should be securely fastened at a minimum 4 points on two opposite sides. • Specific information on the solar module dimensions and location of mounting holes is provided in 'Product Specifications'. Module frame Bolt Flat washer Flat washer Spring washer Nut Support • Tighten the bolt securely by using the combination shown above. Place the spring washer between the Flat washer and Nut. Mounting by using clamps • The module may be fastened to a support by using clamps on both the long edge and the short edge of the modules. • Specific information on location of clipping is provided in 'Mechanical Installation Scene'. (Refer to next page) More than 10mm II This family of single-phase string inverters complements the typical number o,rooftop solar panels enabling homeowners tuget the most eno|o,u energy »mvmtmo for the size of the property. This inverter offers a dual input section that processes two strings with independent Multiple Power Point naomng(KxPPT. This iaespecially useful for rooftop installations with two different orientations from two sub -arrays oriented in different directions, or unbalanced strings (for example: East and West). The dual -input sections with independent IVIPPTenable amore optimal energy harvesting condition. - Additional highlights ' -`��' - - ~="� � - RS~485communication interface (for connection to. laptop ordata logger) ' Available with the optional VSN3OO Wifi Logger Card for easy and affordable wireless monitoring Compliant with NEC 8QO.12when used with ABBsRapid Shutdown device Comes standard with DC Arc Fault Cirouit|ntenupto (AFCVtocomply with NEC OQ0.11 = r'` ^ ' The high-speed mlPPToffers real- time powertraokingand|mproveu energy harvesting. The flat efficiency curve ensures high - efficiency ata||output|ovo|aa||ovving aconsistent and stable performance across the entire input voltage and output power range. The tranaformodoaaoperation gives the highest efficiency ofupto 97.0 percent. The wide input voltage range makes the inverter suitable to low -power installations with reduced string size. This rugged, outdoor inverter has been designed toboacompletely sealed unit, towithstand the harshest environmental conditions. � *rnent gu\\d\nguep6.�'_ - ~- -m»% -.DK8pUANCE REJONED FOR CODE Highlights: - Single-phase and three-phase output grid connection - Wide input -voltage range for increased stringing flexibility and energy harvesting - The high-speed and precise MPPT algorithm offers real-time power tracking and improved energy harvesting - Outdoor NEIVIA4Xrated enclosure for unrestricted use under any environmental conditions - Integrated DCdisconnect switch in compliance with international Standards ('SVersion) Power and productivity for a better world TM Ar% NIP IV Technical data and types Type code pw~30-ourooa pv/'nnooTo'oe pm*8-ourous pvw2-oorous :,General specifications Nominal output power 300OW 360OW 3300 Maximum output power wattage 'Input side (DO) Operating MPPT voltage range Maximum short circuit current limit per channel Array wiring termination Terminal block, pressure clamp, AW020-AWG6 Output side (AG) Grid connection type rid wiring termination type Terminal block, Pressure clamp, AWG20-AWG6 Operating performance Comrnunicatiom VSN700 Data Logger (opt.), VSN300 Wifi Logger Card (opt.) Environmental 'i 'a"p-a' *b- i I' it'y' an"a, b1'ed'at' no- *m- i'n' C v'o-it'a- g* a a-nd with sufficient DC power available. umaosolar inverters | Product flyer for pw-3.mu.em.8/4.u-TL-ouTo - _ Block -diagram-of-PVI=3:0/3:6/3:8/4:2=TL=0UTD -- = - -- - - —`--- ------=---, - --- - - - - -- , - - - - - .- _ _ _ _ ; I - I _ MPPrI - - INVERTER INl.11+) I ' � +, (DClDQ RUIX CAPS RxJA LINE GRID PARALLEL + + + + /� + FILTER RELAY ry1,m'��I, ' —d Ll ' INI INI , , INI INI N i y _ I IN7.2(-) DC- i I , - ' AFDI I I -- - - - -r---, , MPPT2 (DCJDQ i + ' + +I + i IN2 ' —� gE51DUALCLI R IN2 IN2 ; i IN2 IN2 ; I. , IN2 _ DETECTON R5985 PE IN2.1 (-) ' - I +UR STANDARDVERSION -AVERSION -S VERSION •---------- - -------- - - -- -- - - -- - - a - uac REMOTECANTROL•' '------- i _____________ �. DaDc DSP CONTR.•_., o CONT11. T - GRDUND FAULT , �, - P. ' ' OETECIION ALARM CONTROLORCUn L_____________________________________________________________________________- Remote control function not available on -A version PVI 42 'OUTD-US Technical data and types P,VI 4.2=QUTD-U& +R N.0 No C Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US ,Wechanica'l'specifications, Enclosurerating........................................................ ................... ;... ......................................................................... NEMA 4X............................................................................. Cooling .......................................................................................................................................................................... Natural convection ..........................................................-.................................................. ........................... . Dimensions H x W x D 33.8 x 12.8 x 8.71n (859 x 325 x 222mm) ........................................................................................................................................................................................................................................................................................................ Weight.............................................................................................................................................................................................................. <47. 31b..(21.3kg)Z...............,............................................................... Shipping wei9ht............................................... ............................................ ............ ... ......... .[..................................................................................< 601b (27..Okg)................................................................................... Mounting..system Wall bracket ...................................................................................................._€. ..................Trade size iZOs (tea x 172") and (tea x 1-1�4", 3 places sicJe, front, rear) Conduit connections' Side: (2) plugged 3/4" openings, (2) Concentric KOs 3/4", 1" _Back;...(4).Concentric,EKOs 3/41..1............................................................... ................................................................................................................... DC switch rating (per contact) (AN) [ 25/600 =:Safetyand` Compliance=' , . .. Isolation level Transformerless (floating array).................... ............................. ...........................................................................................................s................. UL1741, IEEE1547, IEEE1547.1, CSA-C22.2 N. 107.1-01, UL1998 UL 1699B, FCC Part Safety and EMC standard ......................................................................................... ..............................................................................................................................................................................................................................5a aPProval............ ,Clss..B . ..................... .. CSA .Safety, Regional Compliance Rule 21 HECO NEC 2014 690.11 NEC 690 12 with ABB Rapid Shutdown device Available models , With DC switch, wiring box, arc fault detector and PVI-3.0 0'0TD-9 PVI 3.6-OUTD S PVI-3.8 CUTD S PVI 4 2 C�UTD-5- interrupter......... ........................................................................ US -A US -A US. -A..................................... US..A.................... .................................................................................................. ...............;...........;.............................. 2. When equipped with optional DC switch and wiring box. All data is subject to change without notice Product flyer for PVI-3.0/3.6/3.8/4.2-TL-0UTD I ABB solar inverters 3 Issued to: ABB, Inc. 16250 W. Glendale Drive New Berlin, WI 53151 USA The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Jocelyn Jens Product Group Coordinator CP O C us Authorized by: Lindsay Clark Operations Manager PRODUCTS CLASS 531109 - POWER SUPPLIES - Distributed Generation Power Systems Equipment CLASS 531189 - POWER SUPPLIES - Distributed Generation - Power Systems Equipment - Certified to U.S. Standards Utility Interactive Inverter, Models PVI-42-OUTD-US, PVI-3.8-OUTD-US, PVI-3.6-OUTD-US, PVI-3.0-OUTD-US, PVI4.2-OUTD-S-US, PVI-3.8-OUTD-S-US, PVI-3.6-OUTD-S-US, PVI-3.0-OUTD-S-US, PVI-4.2-OUTD-S-US-A, PVI-3.8-OUTD-S-US-A, PVI-3.6-OUTD-S-US-A, PVI-3.0-OUTD-S-US-A, PVI-42 OUTD US W, PVI-3.8-OUTD-US-W, VI- .6-OUTD-US-W and PVI-3.0-OUTD-US-W, provided with two DC input channels, permanently connected, system ratings as follows: Notes: 1. All above models in this series may include expansion board with wireless antennae option and will be identified with model designation including "—Z" suffix. 2. For details related to rating, size, configuration, etc. reference should be made to the CSA Certification Record or the Certificate of Compliance Annex A. mx CUPERTINO �! ' -ef wilding Department a, l l APR �; _. ! 2 2 REVIEWED FOR CODE COMPLIANCE Reviewed By'. AsA' fflAiiii;�t ` V IRONRIDGE __- _ Roof Mount System __ - AUTHORIZATION TO MARK Built for solar's toughest roofs. IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested All components evaluated for superior structural performance. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. Integrated Grounding UL 2703 system eliminates separate module grounding components. PE Certified Pre -stamped engineering letters available in most states. Design Software Online tool generates a complete bill of materials in minutes. 20 Year Warranty Twice the protection offered by competitors. This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. i j This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. --........ _ _ Applicant: IronRidge, Inc. Manufacturer: IronRidge, Inc. Address: 1495 Zephyr Ave Address: 1435 Baechtel Road Hayward, CA 94544 Willits, CA 95490 Country: USA Country: USA Contact: Yann Schwarz Contact: Jim Norsworthy Phone: (800) 227-9523 Phone: (800).227-9523 (510) 225-0973 FAX: (707) 459-1833 FAX: (707) 459-1833 Email: yschwarz@ironridge.com Email: Norsworthy@ironridge.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CAI �1SL�t GA Control Number: 4007559 Authorized by: for Thomas J. Patterson, Certification Manager ETL CLASSIFIED E / us �famo Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any parry, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in 'its entirety. Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s): UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat -Plate Photovoltaic Modules and Panels, Issue Number: 1, October 4, 2010 Product: XR Rails with Integrated Grounding. Brand Name: N/A Models: 51-61GD-0051 51-61GD-0056, 51-5000-001, and 51-65-001 . ATM for Report 101541132LAX-002 Page 1 of 3 ATM Issued: 10-Nov-2014 3 777 en, E ,4 . v f y '���sy' ,.a.: ED 16.3.15 (1-Jan-13) Mandatory --- -- -- — ------------- - .' rF _ IR R DGE Integrated -Grounding -System instauation Overview For Greater Safety & Lower Cost Traditionally, solar modules are grounded by attaching lugs, bolts or clips to the module frame, then connecting these to a copper conductor that runs throughout the array. This process adds time and cost to the installation, and often results in improper grounding, creating significant long-term safety risks. The IronRidge Integrated Grounding System solves these challenges by bonding modules directly to the mounting rails. This approach eliminates separate module grounding hardware, and it creates many parallel grounding paths throughout the array, providing greater safety for system owners. 2 Install Roof Attachments `� • Install appropriate roof flashing and/or standoff for roof type. - • Attach L-Feet to flashing or standoff. Grounding Mid Clamp Each Grounding Mid Clamp pierces through the anodized coatings of both the module frame and the mounting rail to form secure electrical bonds, which are repeated throughout the array. i � `RL•x "� � f A Grounding Strap Grounding Straps are used to bond rail -to -rail connections. They are only required on the rail with the grounding lug. 3 I Grounding Lug A single Grounding Lug connects an entire row of PV modules to the grounding conductor. Un Prepare Rail Connections • Insert splice into first rail, then secure with Grounding Strap and self -drilling screw. • Slide second rail over splice, then secure with opposite end of Grounding Strap and self -drilling screw. Mount & Ground Rails • Attach rails to L-Feet and level rails. • Install one Grounding Lug per row of modules. • Connect Grounding Lug to grounding conductor. Install Modules & Clamps • Install first module using End Clamps and Grounding Mid Clamps • Install additional modules using Grounding Mid Clamps. • Finish row with a second pair of End Clamps. Testing & Certification The IronRidge Integrated Grounding System has been tested and certified to UL 2703 by Intertek Group plc. UL 2703 is a proposed UL standard for evaluating solar module mounting and clamping devices. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. The testing process closely mirrors that of UL 1703, the solar module testing standard, including temperature and humidity cycling, electrical and mechanical load testing, and manufacturing quality reviews. FBI Module Frame Compatibility A Any module frames whose parameters are not listed in the provided table have not been tested for compatibility. The Grounding Clamp has proven robust in grounding 60-cell and 72-cell solar module frames with box construction and a range of anodization thicknesses. All solar modules listed to UL 1703 and with frame construction within the parameters stated above are compatible with the IronRidge Integrated Grounding System. Go to ironfldge•com/i Dimension Range A � 31.Omm - 51.Omm B 5.08mm (minimum) ,� s.. < ... i ': s.. - .:,�. r.. I IronRidge 1495 Zephyr Ave Hayward, CA 94544 Starling Madison-Lofquist, Inc. Consult-Ing Structural and Forensic Engineers 5224 South 39th Street, Phoenix, Arizona 85040 tel: (602) 438-2500 fax: (602) 438-2505 ROC#291316 www.smleng.com Attn: Mr. David F. Taggart, Vice President Products December 18, 2014 Page 1 of 20 Subject: IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis Dear Sir: We have analyzed the IronRidge XR10 Rail for the subject solar module support system and determined that, for the configurations and criteria described below, it is in compliance with the applicable sections of the following Reference Documents: Codes: ASCE/SEI 7-10 Min. Design Loads for Buildings & Other Structures California Building Code 2012 Edition Other: AC428, Acceptance Criteria for Modular Framing Systems Used to Support PV Modules, dated Effective November 1, 2012 by ICC-ES Aluminum Design Manual, 2010 Edition The IronRidge XR10 Rail is an extruded aluminum section with an overall depth of 1.75 in. and a net area of 0.363 sq.in. The rails are used to support solar modules, typically, on the roof of a building. See Exhibit A — attached. The rails are clamped to aluminum angle brackets that are either attached directly to the roof framing or attached to a stand that is screwed to the roof framing. The rails are mounted across the slope with a small clearance (flush mounting) to the underlying roof structure. The installed solar modules are at the same slope as the underlying roof structure. All loads are transferred to the roof framing through the angle brackets by simple bi-axial flexure of the rails. The maximum span of the rails is governed by either the mid -span flexural stresses or the deflection requirement that the rail not come into contact with the roof. The effect of seismic loads (for all design categories A-F) have been determined to be less than the effect due to wind loads in all load conditions and combinations. Therefore, the maximum allowable spans for common load cases are shown in the tables below. Tables IA-9A are for modules with a maximum long dimension of 67.5 inches and Tables 1B-9B are for modules with a maximum long dimension of 78.5 inches. Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers IronRidge _ December 18, 2014 Mr. David F. Taggart Page 5 of 20 IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis Table 4A - MAXIMUM SPANS (in) - Roof Slope 7° to 27° - Wind Zone 1 (67.5" Max Module Length) Rail Rail Wind Speed Ground Snow Load, - Exposure mph 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 100 75 65 55 49 43 39 35 33 31 29 105 1 75 65 55 49 43 39 35 33 31 29 110 75 65 55 49 43 39 35 33 31 29 Category 120 75 65 55 49 43 39 35 33 31 29 B 130 75 65 55 49 43 39 35 33 31 29 140 71 65 55 49 43 39 35 33 31 29 150 66 65 55 49 43 39 35 33 31 29 160 62 62 54 48 43 39 35 33 31 29 170 59 59 53 47 43 39 35 33 1 31 29 100 75 65 55 49 43 39 35 33 31 29 105 1 75 65 55 49 43 39 35 33 31 29 110 75 65 55 49 43 39 35 33 31 29 120 70 65 55 49 43 39 35 33 31 29 Category C 130 65 64 54 48 43 39 35 33 31 29 140 60 60 53 48 43 39 35 33 1 31 29 150 56 56 52 47 43 39 35 33 31 29 160 53 53 51 46 42 39 35 33 31 29 170 50 50 50 45 41 1 38 35 33 31 29 100 75 65 55 49 43 39 35 33 31 29 105 73 65 55 49 43 39 35 33 31 29 110 70 65 55 49 43 39 35 33 31 29 120 64 64 54 48 43 39 35 33 31 29 Category D 130 60 60 53 47 43 39 35 33 31 29 140 55 55 52 46 42 39 35 33 31 29 150 52 52 50 46 42 39 35 33 31 29 160 49 49 49 45 41 38 35 33 31 29 170 46 46 1 46 44 1 40 37 1 35 1 33 1 31 29 Notes — see page 20 Starling Madison Lofquist, Inc. -5- Consulting Structural and Forensic Engineers _-!�- 1ronRidge December 18, 2014 IronRidge December 18, 2014 Mr. David F. Taggart Page 6 of 20 Mr. David F. Taggart Page 7 of 20 IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis Table 5A - MAXIMUM SPANS (in) - Roof Slope 7° to 27° - Wind Zone 2 (67.5" Max Module Length) Rail Rail Wind Speed Ground Snow Load Exposure mph 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 100 72 65 55 49 43 39 35 33 31 29 105 69 65 55 49 43 39 35 33 31 29 110 66 65 55 49 43 39 35 33 31 29 Category 120 60 60 55 49 43 39 35 33 31 29 B 130 56 56 55 49 43 39 35 33 31 29 140 52 52 52 49 43 39 35 - 33 31 .29 150 49 49 49 49 43 39 35 33 31 29 160 46 46 46 46 43 39 35 33 31 29 170 43 43 43 43 43 39 35 33 31 29 100 61 61 55 49 43 39 35 33 31 29 105 58 58 55 49 43 39 35 33 31 29 110 56 56 55 49 43 39 35 33 31 29 120 51 51 51 49 43 39 35 33 31 29 Category C 130 48 48 48 48 43 39 35 33 31 29 140 44 44 -44 44 43 39 35 33 31 29 150 41 41 41 41 41 1 39 35 1 33 31 29 160 39 39 39 39 39 39 35 33 31 29 170 36 36 36 36 36 36 35 33 31 29 100 56 56 55 49 43 39 35 33 31 29 105 54 54 54 49 43 39 35 33 1 31 29 110 52 52 52 49 43 39 35 33 31 29 120 47 47 47 47 43 39 35 33 31 29 Category D 130 44 44 44 44 43 39 35 33 31 29 140 41 41 41 41 41 39 35 33 31 29 150 38 38 38 38 38 38 35 33 31 29 160 36 36 36 36 36 36 35 33 31 29 170 1 33 33 33 33 33 33 33 33 31 29 Notes — see page 20 Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers Table 6A - MAXIMUM SPANS (in) - Roof Slope 7° to 27'- Wind Zone 3 (67.5" Max Module Length) XR10 Rail Wind Speed Ground Snow Load Exposure mph 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 100 59 59 55 49 43 39 35 33 31 29 105 56 56 55 49 43 39 35 33 31 29 110 54 54 54 49 43 39 35 33 31 29 120 49 49 49 49 43 1 39 35 1 33 31 29 Category B 130 46 46 46 46 _ 43 39 35 33 31 29 140 42 42 42 42 42 39 35 33 31 29 150 40 40' 40 40 40 39 35 33 31 29 160 37 37 37 37 37 37 35 33 1 31 29 170 35 35 35 35 35 1 35 35 33 31 29 100 50 50 50 49 43 39 1 35 33 31 29 105 48 48 48 48 43 39 35 33 31 29 110 45 45 45 45 43 39 35 33 31 29 120 42 42 42 42 42 39 35 33 31 29 Category C 130 39 39 39 39 39 39 35 33 31 29 140 36 36 36 36 36 36 35 33 31 29 150 33 33 33 33 33 33 33 33 31 29 160 31 31 31 31 31 31 31 31 31 29 170 29 29 29 29 29 29 29 29 29 29 100 46 46 46 46 43 39 35 33 31 29 105 44 44 44 44 43 39 35 33 31 29 110 42 42 42 42 42 39 35 33 31 29 120 38 38 38 38 38 38 35 33 31 29 Category D 130 35 35 35 35 35 35 35 33 31 29 140 33 33 33 33 33 33 33 33 31 29 150 31 31 31 31 31 31 31 31 31 29 160 29 29 29 1 29 29 29 29 29 29 29 170 27 1 27 27 1 27 27 27 27 27 27 27 Notes — see page 20 Starling ]Madison Lofquist, Inc. -6- -7- Consulting Structural and Forensic Engineers — - - ---- -- - ----- ----- --.. _ - - - ---- - -- -- - — — - - ---IronRidge =— - —-- December 18, 2014 - _ - - - - - --- - -- - ----Middle o�pvvio535sz USA Mr. David F. Taggart Page 20 of 20Interte Telephone: 608.836.4400 IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis Facsimile: 608.831.9279 www.intertek.com Notes — Tabulated values are based on the following criteria: Tverification Conformity l . Building meanroof height = 30 ft 2. Risk Category I 3. Solar maximum module long dimension is 67.5 inches for Tables lA-9A and 78.5 inches for Tables I13-913. 4. Provide 2 in. clear between roof and rail 5. End cantilever span (max) = 0,40 x maximum span from above tables 6. No rail splices in end spans 7. No rail splices in middle 1/3 of interior spans 8. SingIe simple span(s). Spans listed in the tables above may be multiplied by 1.08 for continuous rails of 3 or more spans. Our analysis assumes that the rails, including the connections and associated hardware, are installed in a workmanlike manner in accordance with the "IronRidge Roof Mount Installation Manual" by IronRidge and generally accepted standards of construction practice. Additional information is available at the IronRidge web site, IronRidge.com. Verification of PV Module capacity to support the loads associated with the given array shall be the responsibility of the Contractor or Owner and not IronRidge or Starling Madison Lofquist. The adequacy of the supporting roof framing is to be determined by others. Please feel free to contact me at your convenience if you have any questions. Respectfully yours, Tres Warner, P.E. Design Division Manager MA U- W --�1-� is?. L C +S CIu11. j.ANC Department �iDE ,()NIPLIANCE Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers -20- In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. Applicant Name & Address: Product Description: Ratings & Principle Characteristics: Models: Brand Name: Relevant Standards: Verification Issuing Office: Date of Tests: Test Report Number IronRidge, Inc. 1495 Zephyr Ave. Hayward, CA 94544 USA XR Rails with Integrated Grounding. Fire Class Resistance Rating: -Flush Mount (Symmetrical). Class A Fire Rated for Low Slope applications when using Type 1, 2 and 3, listed photovoltaic modules. Class A Fire Rated for Steep Slope applications with Type1, 2 and 3, listed photovoltaic modules. Tested with a 5" gap (distance between the bottom the module frame and the roof covering), per the standard this system can be installed at any gap allowed by the manufacturers installation instructions. No perimeter guarding is required. 51-61GD-005, 51-61GD-005B, 51-5000-001 and 51-65-001 IronRidge Roof Mount UL 2703 (Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat -Plate Photovoltaic Modules and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition dated Nov. 18, 2014, (Section 31.2) Standard for Safety for Flat -Plate Photovoltaic Modules and Panels. Intertek Testing Services NA, Inc. 8431 Murphy Drive Middleton, WI 53562 08/27/2014to 03/17/2015 101769343MID-001r1, 101769343MID-001a, 101915978MID-001 & 101999492MID-001ar1-cr1. This verification is part of the full test report(s) and should be read in conjunction with them. This report does not automatically imply product certification. Completed by: Chad Naggs Reviewed by: Gregory Allen Title: Technician 11, Fire Resistance Title: Engineering Team Lead, Fire Resistance Signature: /% Signature: Date: 03/30/2015 Date: 03/30/2�15 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product or service is or has ever been under an Intertek certification program. GFT-OP-11a (24-MAR-2014) - - — -- -- - - -- -- -- - - - — - - — — -- - - -- -- — — - - -- --- - -- --- - - - -: -_- _ _-__: -------E=Mount-La Installation --Instructions- lnstallationTools Required: tape measure, roofing bar, chalk line, stud finder, caulking gun, sealant compatible with roofing materials, _.._ __. _ _ ....... drill with 7/32" long -style bit, drill or impact gun with 1/2" socket. THIS EDGE TOWARDS ROOF RIDGE 9.00 ITEM NO. DESCRIPTION QTY./BOX i 1 FLASHING, 9" X 12" X .040", 5052, MILL 1 2 QBLOCK, CLASSIC, A360.1 CAST AL, MILL 1 3 PLUG, SEALING, 5/16" X 7/8", EPDM / 18-8 SS I _I 4 LAG SCREW, HEX HEAD, 5/16" x 5-1/2", 18-8 SS I j 5 WASHER, FENDER, 5/16" ID X 1-1/4" OD, 18-8 SS 1 ulck Mount TITLE AVAILABLE IN MILL, AND QMSE-LAG: QMPV E-MOUNT 3RONZE ANODIZED FINISHES WITH LAG BOLT FRoPRIETAW AND CON NDENTIAL THEINFOR"TION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION IN PARE OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF QUICK MOUNT PV IS PROHIBITED. 5 4 DIMENSIONS ARE IN INCHES TOLERANCES: ------- ---. FRACTIONAL_ 1 /8 DO NOT SCALE DRAWING TWOPLACEDECIMAL 2A8 THREE PLACE DECIMAL 2.125 3 2 WE I DRAWN BY: DFM REV A i DATE: 8/29/2014 I 7 SCALE: 1:3 WEIGHT:0.96 i SHEET I OF 1 Lag pull-out (withdrawal) capacities (lbs) in typical lumber: Lag Bolt Specifications Specific Gravity 5/16" shaft per 3" thread depth 5116" shaft per 1" thread depth Douglas Fir, Larch .50 798 266 Douglas Fir, South .46 705 235 Engelmann Spruce, Lodgepole Pine (MSR 1650 f & higher) .46 705 235 Hem, Fir .43 636 212 Hem, Fir (North) .46 705 235 Southern Pine .55 921 307 Spruce, Pine, Fir .42 615 205 Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) .50 798 266 Sources: American Wood Council, NDS 2005,Table 11.2 A,11.3.2 A Notes: 1) Thread must be embedded in a rafter or other structural roof member. 2) See NDSTable 11.5.1 C for required edge distances. s Pv) u�+c ount RE:SPI CT THE ROOF Locate, choose, and mark centers of rafters to be mounted. Select the courses of shingles where mounts will be placed. Using drill with 7/32" bit, drill pilot hole into roof and rafter, taking care to drill square to the roof. Do not use mount as a drill guide. Drill should be 'long style bit, aka 'aircraft extension bit'to drill a 13/4" deep hole into rafter.. Carefully lift composition roof shingle with roofing bar, just above placement of mount. Remove nails as required. See "Proper Flashing Placement" on next page. Insert flashing between 1 st and 2nd course. Slide up so top edge of flashing is at least 3/4" higher than the drip edge of the 3rd course and lower flashing edge is above the drip edge of 1 st course. Mark center for drilling. Clean off any sawdust, and fill hole with sealant Slide the flashing into position. Insert the rubber compatible with roofing materials. plug into the QBlock cavity. Slide the washer and the L-foot (not included) onto Using a 1/2 inch socket on an impact gun drive the lag screw. the lag screw until the QBlock stops rotating easily. DO NOT over -torque. BI 7.2.3-31 Sep-2014, Rev 1 BI 7.2.3-31 Sep-2014, Rev 1 ■ -- — -- - -- - - -- --- .`-��� Rp-. - IN I C-�- �1a�M`_ _ - - = DIAGRAM - TYPICAL CONFIGURATION _ - Product Datasheet ENERGY __ i .P :9®= 1!!� -- Shielded CATS 1®� ®!• INTERNET ��` t I • RESIOENTIAL SOLAR MONITORING SOLUTION I�� { _ The LGate 120 is a • • - • • 1 f,E P3iiIDiE 3¢ �®M MI= ELECTRICAL fo"r rerno.te• • • of • . photovoltaic '` ��� ®� SERVICE i ter•., WM ®M coMmunications •• -P • ��. ®� �® INVERTER(S) LGATE 120 The LGate 120 combines a revenue -grade, solid-state power meter with an advanced communications gateway. These components work in conjunction to remotely monitor the performance of residential solar energy installation regardless of panel or inverter type. The LGate 120 is a one-piece completely under glass meter which installs easily using a standard socket base. Performance data is uploaded in near real-time to the Locus Energy SolarOS monitoring platform which provides a suite of tools and analytics for asset managers. DATA COLLECTION AC energy data is collected by the meter and passed to the communications module. Additional system performance data can be collected directly from meteorological sensors and supported inverters via available RS-485 or Zigbee connections. All data is stored in non-volatile memory and then automatically uploaded to the SolarOS and SolarNOC platforms. NETWORK CONNECTIVITY The communications gateway inside the LGate 120 supports plug and play connectivity through a cellular or available Ethernet network connection. Once the unit is installed and powered on, it will immediately begin transmitting data without any configuration. For maximum reliability, the communications gateway will automatically route uploads between the wireless and wired connections if either of the networks are unavailable. FEATURES • ANSI 02.20 power meter • RS-485 and Zigbee inputs • GSM cellular or Ethernet connectivity • Over the air firmware updates • Easy, low cost installation • Doesn't require entrance into the building • Plug and play activation • LCD display PV ARRAY DIMENSIONS i LOCUS ENERGY METER BASE, COMM MODULE METER MODULE s� SPECIFICATIONS DATALOGGER Processor- ARMS) embedded. CPU OS Custom version of Linux 16, OTA firmware updates Memory, 128 MB RAM Display LCD screen Enclosure. . NEMA 3R Type Weight, 8 oz Dimensions 6.95" x 6.5" x 7.3" Environment 720 to 60C, all-weather Warranty, 5 year limited warranty OPTIONSCOMMUNICATION INTERFACE Model Number LGatel20-3Gx I.Gate120-3Gy LGate120-3Gz . Cellular. -3G GSM �/ ✓ RS-485 2'and 4 wire ✓ Modbus Zigbee, Ethernet RJ-4510/100, DHCP/Static SOCKET METER 6.95 in 6.31 in 5.46 in 6.00 in — 7.30 in Accuracy ANSI 12.20 (Class 0.2%) Voltage Inputs. 120 - 480 VAC Max. Current Input' 200 A Service Type Single phase, 60 Hi Socket Type 2S COMPLIANCE ANSI 12120 class 0.2% FCC Part 15B. PT.CRB AT&T Carrier Compliance' " Single Meter Sockets - Without Bypass _ _ _ ___ Single= Meter Sockets=- Without Bypass _ 125 & 200 Amp 011 (closed) U204(open) Application • Single meter position • Receive ANSI C12.10 watthour meters • Surface or flush mount (see chart) Construction • Ring type • NEMAType 3R � Q • ANSI 61 gray E-coat finish • Aluminum snap ring included Standards Accessories • UL 414 Listed • 5th Jaw Kit - 50365 • ANSI C12.7 • 200ATriplex Ground - ETB200 • AW Hub Part/UPC Catalog Amp Service Connections Number Number Rating Jaws Type Access Line Load Neutral 78205142000 011 125 4 10/3W OH%UG #14 - 2/0 #14 - 2/0 #14 - 2/0 78205142040 011 F 125 4 10/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 78205142045 011 MS73 125 4 10/3W OH/UG #14 - 2/0 #14 - 2/0 #14.- 2/0 78205142050 011 SF 125 4 10/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 78205144030 927 - 1D0 7 30/4W OH/U13 #14 -1/0 #14 -1/0 #14 - 2/0 78205156000 204 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156020 204 F 200 4 10/3W OH _ #6 - 250MCM #6 -.250MCM- #6 - 350MCM 78205156030 204 F MS73 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156040 204 MS68 200 4 10f3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156035 204 MS68A 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 18205108490 204 MS73 20014 10/3W OH #6 - 250MCM' #6:- 250MCM #6 - 350MCM 78205156005 U204 200 4 10/3W UG #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156045 U204 F 200 4 10/3W UG . #6- 250M4A #6--, 25-W(M #6'- 350MCM 78205156060 U204 F MS73 200 4 10/3W UG #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156070 U204 MS73 200 4 10/3W UG #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156140 U207 200 7 30/4W OH/UG #6 - 250MCM #6 - 250MCM #6 - 250MCM 78205156170 U207 F 200 7 30/4W UG #6"- 2501VICM #6 - 250MW #6 - 250MCM 78205156180 U207 MS73 200 7 30/4W OH/UG #6 - 250MCM #6 - 250MCM #6 - 250MCM Part/UPC Catalog Overall Dimensions Top Knockout Number Number Height Width Depth Provision Layout 78205142000 011 12" 8" 45/a" AW Hub Fig. 1 78205142040 011 F 12" 8"" 45/a" 2" max KO Fig. 1 78205142045 011 MS73 12" 8" 45/e" - AW Hub Fig. 1 78205142050 011 SF 12" 8" 45/8" 2" max KO Fig. 1 78205144030 927 17" 8" 45/8" AW Hub Fig. 1: 78205156000 204 15" 8" 45/a" AW Hub Fig. 2 78205156020 204 F 15" 8" 6" 2" max KO Fig. 2 78205156030 204 F MS73 15" 8" 6" 2" max KO Fig. 2 78205156040 204 MS68 15" 8" 45/8'' AW /'2" Hub Fig. 2 78205156035 204 MS68A 15" 8" 45/a" AW / 2" Hub Fig. 2 78205108490 204 MS73 15" 8" 4%" None _Fig. 2 78205156005 U204 15" 12" ON' None Fig.3 782051.56045 U204 F 15" 12" 6" (2) 2" max KO Fig. 3'. 78205156060 U204 F MS73 15 12' 6" None Fig. 3 78205156070 U204 MS73 15 12" 45/8" None Fig. 3 78205156140 U207 18" 12" 5" AW Hub Fig. 4 AIC Note: 78205156170 U207 IF 18" 12'" 5'" 21/2" max KO Fig. 4 For short circuit current 78205156180 U207 MS73 18" 12" 5" AW Hub Fig. 4 ratings see page 131. B-Line by Fff-N Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 5 Meter Mounting Equipment Oil F - Flush Mount (U) 204 MS68 - 2" Conduit Hub (U) 207 MS68A - MS73 + MS68 927 MS73 - AL Screw Type Ring SF - Semi Flush Mount SS - Stainless Steel Knockout Layouts Fig. 1 Top Provision 0 4F 4F both sides 1A Fig. 3 :,-4Top Provision 4F 4G 4F s de Os e 4G 1 W 125 & 200 Amp 1W=1/4" 1 A = 1/2' 2A = 1/2' - 1/4' 4F=2"-11h'-11/4'-1' 4G=21/T-2"-11/2'-11/4' Top Provision = See Chart Fig. 2 Top Provision 11 0 4F both sides 4F 1A Fig. 4 Top Provision 0 4113 4G 4G b3 th sides b,o 4G 2A Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment 6 B-Line by IFa•IJU nd lop ENERGY October 22"d, 2013 This letter is to certify that the I -Gate 120 and I -Gate 320 are communication boards built into the Vision Meter 2S CL200 and 16S CL320 socket meters, respectively. Each of these meters was certified to the ANSI C12.20 (class 0.2%) standard by Underwriters Laboratory on June 7, 2013 as part of the Vision Meter Family (Project Number 12CA71134, Job Number 1001541515, and Report Number R12CA71134- ANSI). ANSI C12.20 is currently recognized as the industry standard for electrical socket meters in both utility and PV monitoring applications. These tests cover both meter accuracy as well as several safety standards including electrical and environmental safety, as well as resistance to various types of mechanical shock. As electrical socket meters are generally installed and maintained by trained and certified professionals, rather than consumers, they do not fit the typical criteria for additional types of UL or IEC certification. If you have any further questions regarding the product certification of any Locus Energy I -Gate -branded device, please contact us at support@ locusenergy.com. The Locus Energy Team Locus Energy, LLC www.locusenergy.com --—CIgSSIC -Conduit-Com os�t�on-Mount-_6Z11/I =C,_ __ _ - _ _ - Classic Conduit-Mouritin- -Instructions-- - - -- _ Installation Tools Required: tape measure, roofing bar, chalk line, stud finder, caulking gun,1 tube of appropriate sealant, drill with 1/8" bit, drill or impact gun with 7/16" deep socket. TI — 1--r! Tr %S I A I'Sf1C 1`1/l 17 nlflr"C 79 i PROPRIETARY AND CONFIDENTIAL ME INFORMATION CONTAINED W THIS DRAWING U THE SOLE PROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION W PART OR AS A WHOLE WITHOUT ME WRITTEN PERMISSION OF QUICK MOUNT PV IS PROHIBITED. 5 4 ITEM NO. DESCRIPTION QTY. I FLASHING, 9" X 12" X .040", 5052, MILL 1 2 QBLOCK, CONDUIT, 5/16", 6061-T6, MILL 1 WASHER, SEALING, 1/4" ID X 7/8" OD, EPDM 3 BONDED SS 1 4 LAG SCREW, HEX HEAD, 1/4" x 2-1 /2", 18-8SS 1 AVAILABLE IN MILL, CLEAR ANODIZED, AND BRONZE ANODIZED FINISHES. TITLE: Jvioun.T rv-- QMCC: CLASSIC CONDUIT COMPOSITION MOUNT urvLlaa -m—L-SrDL.Ineu_ SIZE DRAWN BY: RAD REV DIMENSIONS ARE IN INCHES I ' TOLERANCES: A DATE: 9/24/2013 `+ ......._.._......... ......___.._.._........__.—......_.._ FRACTIONAL21le �. TWOPLACEDECIMAL :.18 r._._...__....--r.__--..__..._..______.._.....-_.._......_._... DO NOT SCALE DRAWING THREE PLACE DECIMAL t.125 SCALE: 1:3 WEIGHT:0.68 SHEEr I OF 1 3 2 1 .. . ..capacities Lag Bolt Specifications Specific Gravity 1/4" shaft per 1 3/4" thread depth 1/4" shaft per 1" thread depth Douglas Fir, Larch .50 393 225 Douglas Fir, South .46 353 202 Engelmann Spruce, Lodgepole Pine (MSR 1650 f & higher) .46 353 202 Hem, Fir .43 313 179 Hem, Fir (North) .46 353 202 Southern Pine .55 455 260 Spruce, Pine, Fir .42 302 173 Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) . 00 393 225 Sources: American Wood Council, NDS 2005,Table 11.2 A,11.3.2 A Notes: 1) Thread must be embedded in a rafter or other structural roof member. 2) See IBC for required edge distances. IMPORTANT: To maintain waterproofing it is important that the aluminum flashing (item 1) is properly placed under one full course above the mounting block with at least some of the flashing extending up under the course above that- wall (;— inctrl Irtinnc nn harlr quick Mount PV RESPECT THE ROOF BI 7.2.3-8 Aug-2014, Rev 4 WARNING: Quick Mount PV products are NOT designed for and should NOT be used to anchor fall protection equipment. Choose placement of conduit mounts along path Lift composition roof tile with roofing bar, just Slide conduit mount into desired position. Remove of conduit. Select location over center of rafter. above placement of conduit mount. any nails that conflict with getting the mount flush with front edge of shingle course. Mark cernter for drilling. Using drill with 1/8" long bit, drill pilot hole into roof and rafter, taking care to drill square to the roof. Clean off any sawdust, and fill hole with roof Lift shingle and slide conduit mount into place. manufacturer's approved sealant. Prepare lag bolt with sealing washer and single hole clamp (not included) as shown. Insert lag through hole in block, and position clamp over conduit. CUPERTINO 5I,jildina Department APB 12 201 _.1 .; , ;UDE COMPLIANCE (F;evleweO BY Insert, lag through hole in block, and position clamp over conduit. Using drill with 7/16" socket, drive lag until block is tight. Quick Mount PVD 925-478-8269 • www.quickmountpv.com • info@quickmountpv.com BI 7.2.3-8 2700 Mitchell Dr., Bldg 2 • Walnut Creek, CA 94598 Aug-2014, Rev 4 02013 by Quick Mount PV. All rights reserved. ' i • e 1 COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 buildinq�cupertino_ong 1iLE� Permit No. B-2016-1758 Address 20688 Shelly Drive # of Alarms Smoke: Carbon Monoxide: 41- PERMIT CANNOT BE FINALED AND COMPLETEDUNTIL THIS CERTIFICATE 14AS RFF.N STf NFT):ANT) RTTITRNF.D TO THE RTTTI DING T)TVTSTtlN PURPOSE This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated.. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below. and aaree to comply with the terms and conditions of this Owner (or (or Owner Agent's) Name: H� ................... Date:/ /�_?14 Contractor Name: Sianature................................................................... Lic.#...................................,.. Date: ................... Smoke and C'O forin.doe revised 03118114 CUPERTINO WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE-'CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 buildinq(@cupertino.org Owner Name % Permit No.�{� Address 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. No Go to Question 2. 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form. `Z No Go to Question 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. 'IS-- No Go to Question 4. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. +b4 Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form.. Please check ONE of the following: My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non -compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations,or improvements shall require non compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). 1, as the owner or owner's agent of this property, certify under penalty of perjury that non -compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water -conserving plumbing fixtures comply with the requirements as indicated in the table on the following page. Owner or Owner Agent's Signat /l o Date: Unon comnletine and signing this Certificate. please return it to the Building Division in order to final your building permit. SB407 2015. doc revised 08126115