Loading...
B-2016-1421r CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2016-1421 22266 HARTMAN DR CUPERTINO, CA 95014-1020 (326 13 087) ( BAY AREA SOLAR SOLUTIONS INC) PLEASANTON,CA 94588 OWNER'S NAME: SCHANNON DAVID AND DENISE DATE ISSUED: 02/23/2016 OWNER'S PHONE: 617-947-5110 PHONE NO: 925-380-9500 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class B Lic. #928652 Contractor ( BAY AREA SOLAR SOLUTIONS INC) Date 02/22/2016 X BLDG _ELECT _PLUMB MECH X RESIDENTIAL COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing _ with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: 5.6 KW ROOF/ FLUSH MOUNTED PV SYSTEM, (18) PANELS I hereby affirm under penalty of perjury one of the following two declarations: 1. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which Sq. Ft Floor Area: Valuation: $22300.00 this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above APN Number: Occupancy Type: information is correct. I agree to comply with all city and county 326 13 087 326 ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and PERMIT EXPIRES IF WORK IS NOT STARTED expenses which may accrue against said City in consequence of the WITHIN 180 DAYS OF PERMIT ISSUANCE OR granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal 180 DAYS FROM LAST CALLED INSPECTION. Code, Section 9.18. Issued by: ABBY AYENDE , gnature Date 02/22/2016 Date: 02/22/2016 OWNER -BUILDER DECLARATION RE -ROOFS: I hereby affirm that I am exempt from the Contractor's License Law for one of the All roofs shall be inspected prior to any roofing material being installed. If a roof is following two reasons: installed without first obtaining an inspection, I agree to remove all new materials for 1. I, as owner of the property, or my employees with wages as their sole inspection. compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) Signature of Applicant: 2. I, as owner of the property, am exclusively contracting with licensed Date: 02/22/2016 contractors to construct the project (Sec.7044, Business & Professions Code). ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the HAZARDOUS MATERIALS DISCLOSURE performance of the work for which this permit is issued. I have read the hazardous materials requirements under Chapter 6.95 of the 2. I have and will maintain Worker's Compensation Insurance, as provided for California Health & Safety Code, Sections 25505, 25533, and 25534. I will by Section 3700 of the Labor Code, for the performance of the work for which maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the this permit is issued. Health & Safety Code, Section 25532(a) should I store or handle hazardous a. I certify that in the performance of the work for which this permit is issued, I material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I shall not employ any person in any manner so as to become subject to the will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and Worker's Compensation laws of California. If, after making this certificate of the Health & Safety Code, ections 25505, 25533, and 25534. exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shalllOiivner `//%/ or authorized agent: be deemed revoked. Date: 02/22/2016 APPLICANT CERTIFICATION CONSTR TION LENDING AGENCY I certify that I have read this application and state that the above information is I hereby affirm that there is a construction lending agency for the performance correct. I agree to comply with all city and county ordinances and state laws of work's for which this permit is issued (Sec. 3097, Civ C.) relating to building construction, and hereby authorize representatives of this city Lender's Name to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, Lender's Address judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant ARCHITECT'S DECLARATION understands and will comply with all non -point source regulations per the I understand my plans shall be used as public records. Cupertino Municipal Code, Section 9.18. Licensed Professional Signature Date 02/22/2016 -20ju_- ILk7.1 GENERAL PERMIT APPLICATION M(tp COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 v FAX (408) 777-3333 • building(alcupertino.org CUPERTINO MISC ❑ PLUMBING ❑ MECHANICAL , ,ELECTRICAL ❑ MISCELLANEOUS PROJECT ADDRESS .22 2 6( I /��� p APN # 32 , 0 97 OWNERNAME UG� K l' PHONE (�17)9y7--51�v E-MAII�Gr✓/ .SC/avj+g.Ot� Li-�c��l,Cat.�i BVI ! uuiKpl�t CSI `2 STREET ADDRESS.,2y 6 L �Y p CITY, STATE, ZIP /'� r ,(� d / C FAX CONTACT NAMEV 5 PHONE&29 vyry� E M4I,,���� 4� �� Fjk� CJN2r/ SO1aTa (- STREET ADDRESS 215 p I e� %�� CI fea STATE, et�Z� LA' �� r � � ff FAX ❑ OWNER ❑ OwNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR KONTRACTORAGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME 0�7 1jr, lO l u✓ �G /� 'i10 S LICENSE NUMBER I-?5652 LICENSE TYPE BUS. LIC # j �OA COMPANY NAME . S r '' / FAX j l�,cE-MAIL if E-MAIL6��vtey' Sa��,I��o�S•co STREET ADDRESS �'�� j�r1 �� �/ S�f� CITY, STATE, ZIP bleuf 2 PHONE /'P5 ARCHITECT/ENGINEER NAME / LICENSE NUMBER BUS. LICC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF SFD or DUPLEX ❑ MULTI-FAMILY PROJECT IN WILDLAND ❑ YES PROJECT IN ❑ YES IS THE BLDG AN ❑ YES BUILDING: ❑ COMMERCIAL URBAN INTERFACE AREA lja_ FLOOD ZONE NO EICHLER HOME? ❑ NO DESCRIPTION OF WORK �4 AV roof- rz, o,,t -144 if V TOTAL VALUATION: 2 L/ 3® *' RECEIVED BY:affi4 By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property o er's b half. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating toconstruction. I raze representatives of Cupertino to enter the above-identified property for inspection purposes. Signature of Applicant/Agent: Date: 3/ZC C UPPLEMENTAL INFORMATION REQUIRED OFFICE USE ONLY �W OVER-THE-COUNTER F ❑ EXPRESS x ❑ STANDARD U , a❑ LARGE ❑ MAJOR jWEPMiseApp_2011.doe revised 06/21/11 Cef/t PROJECT DATA PROJECT ADDRESS: 22266 HARTMAN DR. CUPERTINO, CA 95014 APN: 326-13-087 OWNER: DAVID SCHANNON 22266 HARTMAN DR. CUPERTINO, CA 95014 (617) 947-5110 CONTRACTOR AND DESIGNER: YOUR ENERGY SOLUTIONS LIC.# 5128652 2150 RHEEM DR. SUITE D PLEASANTON, CA 945EIB 925-344-5890 SCOPE OF WORK: INSTALL A 5.6kW GRID -TIED PHOTOVOLTAIC. SYSTEM TOTALING (18) LG315N1C-G4 MONO MODULES WITH (18) P320 DC OPTIMIZERS (1) SOLAREDGE 760OA-US INVERTER. MODULES WILL BE FLUSH MOUNTED ON COMPOSITION SHINGLE ROOF. SITE SPECIFICATIONS: OCCUPANCY: SINGLE FAMILY DWELLING DESIGN WIND SPEED: 110 MPH EXPOSURE CATEGORY: C ROOF HEIGHT: 24'-0" DESIGN SNOW LOAD: 0 psf ROOF SPECIFICATIONS: ROOF COMPOSITION SHINGLE 2x4 TRUSS @ 24" OC PITCH. 18° (4/12) AZIMUTH: 275° 18 MODULES EQUIPMENT SPECIFICATIONS: MODULE: (18) LG315N1 C -G4 MONO INVERTER: (1) SOLAREDGE 760OA-US INVERTER DC OPTIMIZERS: (18) P320 RACKING: IRON RIDGE XR10 ATTACHMENT FLASHING: QUICK MOUNT E -COMP LAG ROOF MOUNTED PHOTOVOLTAIC SYSTEM DC Rating,, 5.6kW DAVID SCHANNON 22266 HARTMAN DR. CUPERTINO, CA 95,014 Jurisdiction: CITY OF CUPERTINO GENERAL NOTES SHEET INDEX SHEET NO. SHEET TITLE: PV -001 COVER SHEET COMMUNITY EVELPV-AO'IlT DEPARTMENT SITE PLAN BUILDIN DIVISION -CUPERTINO - __ZV_-A02._. SYSTEM LAYOUT job site during c charges or The stamping of th' I— `-.sld to permit 1. SYSTEM FOLLOWS ANY/ALL F=IRE CODE SETBACKS PER ORDINANCES OF THE CITY OF .iy proons CUPERTINO. 2. ALL PROJECTS WILL COMPLY WITH THE ORDINANCES OF THE CITY OF CUPERTIN(�y 3. CONSTRUCTION HOURS: 7am-8pm MONDAY - FRIDAY, 9am-8pm SATURDAY, NO TIMEDQ�SUNDAY OR LEGAL HOLIDAYS. (SUBJECT TO CHANGE) 4. PRODUCT DATA SHEETS WILL BE INCLUDED, PERMIT NO. 5. ROOFTOP PENETRATIONS WILL BE COMPLETED AND SEALED PER CODE BY LICENSED CONTRACTOR. 6. ALL PHOTOVOLTAIC MODULES WILL BE TESTED AND LISTED BY A RECOGNIZED LABORATORY 7. CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730. 8. A CONTINUOUS GROUND WILL BE PROVIDED FOR THE ARRAY AND FOR ALL PHOTOVOLTAIC EQUIPMENT. 9. DC WIRING WILL BE RUN IN METAL CONDUIT OR RACEWAYS WITHIN ENCLOSED SPACES IN A BUILDING. 10. CONDUIT, WIRE SYSTEMS AND RACEWAYS WILL BE: LOCATED AS CLOSE AS POSSIBLE TO RIDGES, HIPS AND OUTSIDE WALLS, 11, CONDUIT BETWEEN SUB ARRAYS AND TO DC COMBINERS/DISCONNECTS WILL USE GUIDELINES THAT MINIMIZE THE TOTAL AMOUNT OF CONDUIT BY TAKING THE SHORTEST PATH. 12. SPACE REQUIREMENTS FOR ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110. 13. EQUIPMENT GROUNDING WILL BE SIZED IN ACCORDANCE WITH TABLE 21,50.122. 14, CONNECTORS THAT ARE NOT READILY ACCESSIBLE AND ARE USED IN THE CIRCUITS OPERATING AT OR OVER 30V AC OR DC, SHALL REQUIRE A TOOL FOR OPENING AND ARE REQUIRED TO BE MARKED "DO NOT DISCONNECT UNDER LOAD" OR " NOT FOR CURRENT INTERRUPTING", PER 690.33 (c) & (e). 15. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. 16. SIGNS OR DIRECTORIES WILL BE ATTACHED TO THE ELECTRICAL EQUIPMENT OR LOCATED ADJACENT TO HE IDENTIFIED EQUIPMENT. 17. SIGNS SHOULD BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT. 18, ANY PLAQUES WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERS, OR ELECTRO -PLATING, IN A RED BACKGROUND WITH WHITE LETTERING, A MINIMUM OF HEIGHT AND ALL CAPITAL LETTERS. 19. ALL INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AC PHOTOVOLTAIC MODULES, SOURCE CIRCUIT COMBINERS AND CHARGE CONTROLLERS INTENDED FOR USE IIV A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (d). 20. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOLID WASTE, PETROLEUM BYPRODUCTS, SOIL PARTICULATE, CONSTRUCTION WASTE: MATERIAL OR WASTE WATER GENERATED PM CONSTRUCTION SITE OR BY CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED, OR DISCHARGED INTO THE STREET, GUTTER, OR STORM DRAIN SYSTEM. 21. FINE STRANDED CABLE WILL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR CONNECTORS THAT ARE IDENTIFIED AND LISTED FOR SUCH USE PER THE 2010 CEC 690.31 (f) AND 690.74. spec%&Wns MUST be kept &+MING PLAN tructi��t�� s unlawful to make,aVrl rations d ame, or to deviate �C k.�w.� apprglam the Building OffigidNAGE planfications SHALL NOT r to *T�Pcrioval of the viol aPVrM0DULE SPEC any j dinance or Stal, INVERTER SPEC IPV- , i RACKING SPEC [ACHMENT/FLASHING SPEC PV -1305 GROUNDING SPEC CODES REFERENCES 2013 CALIFORNIA ELECTRICAL CODE (2008 NEC) 2013 CALIFORNIA ENERGY CODE 2013 CALIFORNIA FIRE CODE (2005I_IFfwk, , 2013 CALIFORNIA BUILDING CODE (26d9 I6C ' F �F� t;4::L 2013 CALIFORNIA RESIDENTIAL CODE (2009 IRC)f � 2013 CALIFORNIA MECHANICAL CODE (2009 UMC)- 2013 CALIFORNIA PLUMBING CODE (2009 UPC) CITY OF CUPERTINO BUILDING CODE CITY OF CUPERTINO ELECTRICAL CODE CITY OF CUPERTINO MECHANICAL CODE CITY OF CUPERTINO PLUMBING CODE CITY OF CUPERTINO FIRE CODE 2011 NATIONAL ELECTRICAL CODE ASCE/ANSI 7.10 MINIMUM DESIGN LOADS FOR 0 U.11 -DING" Q1JjE ES1.RUj.TUREk,-,j FF-rl(;%.#%JPN VICINITY MAP LL) Ir z o m Z N Q = P J U N Z N In I() QJ 0 ZD ul a) m' o � 4h � wz 0 z Lu IY L.1 z w �J 00 w 00 I� n N 0) Q U ^ o C z w = a V�[ n) o a N z Q 1x tret11? rn z 5 �LIANGE w Ir 9 w v Z � FLJ � Z z a �� Q w L � . V) U CL LL. 0 U O Ln 0 LQ > F= o <C c� = C�l cc c� N N N SHEET TITLE: COVER SHEET SHEET NUMBER: P V — c: O SHEET 1 OF 1 REV: w � z o � O1 05 m ci N = r N l J � tp Q � z .� t� Lr) CJ o � � � � !Y v �k Z O Lu Ld � U, �] ZO W Ir co 00OLd '� ul-) C f— f U Z O r LLJ = Q a W O ) Or� LrEn N F - E E] Z Q 118 PV MODULES 0 FACING 275° W 4/ I 112 (18.43°) PITCH z 0 C] w SHEET NUMBER: PV -/x,01 SHEET 1 OF 1 REV: C V PC R e �# w s "s Bull aiCie�. Dep ,..." 'FEB 2 3'2016 O 'n [] I REV�IEVVEG FOR CODE COAAPLIA, _ z ; LJ w I Review- Bye. Q� � `s cn o Lt; _ (CD CJ U O ct> Q r� n = a- co N c� N N SITE PLAN N SHEET TITLE: SITE PLAN SCALE: 1/16" = 1'-O" SHEET NUMBER: PV -/x,01 SHEET 1 OF 1 REV: 18 PV MODULI= FACING 2750 V 4/12 (18.43°) PITCI ROOF PLAN LAYOUT SCALE: 1/8" = V-0" NOTES 1. 18° ROOF PITCH 2. 2X4 DF TRUSS @ 24" O.C. 3. COMPOSITION SHINGLE ROOF 4.(18) LG 315N1C-G4 PV MODULES 5. (18) SOLAR EDGE PP320 DC 6. QUICK MOUNT E COMP LAG 7. IROWDGE XR10 RAIL 8. A MIN OF X-0" CLEARANCE BETWEEN PANELS ON CONNECTING ROOFS 9. A MIN OF T-0" CLEARANCE BETWEEN TOP OF PANELS AND THE RIDGE OF THE ROOF KEY/ COMPONENTS SOLAR EDGE P320 DC Ll OPTIMIZER, LG 315N1C-G4 - PV MODULE NEMA 3R JBOX 3/4" EM'r CONDUIT CJPC Bu�Iding DePar FER Z 3 29 REVIEWED FUR DOUE COMPLIAA I Revio. wed By: 1 o: (n o: (n O co m Z_ N N s- N N Z, Z `14o \ p a) p N :- to pq CJ C47 z u .. m Aloo WW- Z p Z z � t,1 U) F IY LL, 2j a� U n 00 F- � rn � U A� n z O V = a o NCL N z a 0 V) z 0 V) w a: w o: w � n z °' F- m- o 6 a w C� >- Z z o �o QU, � a.U im n Q J (/) o n O n O o w0 `n > .. �= o Q ri N N SHEET TITLE: SYSTEM LAYOUT SHEET NUMBER: PV -A\02 SHEET 1 OF 1 REV: 18 PV MODULES FACING 275'" 4/12 (18.43°) PITCF 2X4" D.F. RAFTERS 0 24" O.C. (TYR) SYSTEM SIZE 5.6 kW DC MODULE TYPE LG315NiC-G4 z 0 o MODULES IN ARRAY 18.00 MODULE WEIGHT (Ibs) 44.00 TOTAL MODULE WEIGHT 792.00 RACKING(Ibs)/MODULE 2.90 TOTAL RACKING WEIGHT (Ibs) 52.20 TOTAL ARRAY WEIGHT (Ibs) 844.20 J MODULE AREA 17.48 TOTAL ARRAY AREA 314.64 Ibs/ Sq ft (LESS THAN 5 -OK) P.68 r) — cV ch NUMBER OF VERTICAL SUPPORTS 30.00 Ibs PER SUPPORT (LESS "i HAN 45 - OK) 28,14 FRAMING PLAN SCALE: 3/32" = V-0" IRON RID(== YRin oeu UAY cceti = Al IRO'NRIDGE GR M IRON X IRON RIDGE XR10 RAIL MAX SPAN = 6'-0' QUICKMOUNT PV SPACING = 24" - 72' N IV /11 FRAMING CROSS SECTION SCALE: NTS ATTACHMENT DETAIL SCALE: NTS VRIDGE RATED L -FOOT " SS BOLT Ct!PLZ FEP 2 31 aEl'lEWED FOR CODE Cpm Reviev�ej By. ; S LAG BOLT 5" PENETRATION Or-MLr-U vV/APPROVED SEALANT U-1 z 0 o m N = N 00 uN Z N N J 00 0 Z (n r) — cV ch O z 0 W Ln rn =1k W� m p Z W .. LV > x w Zir '- Ld a nd o 6 o a 0 00 O H Lo 0) � U Z O LLJ Q = a o CLN r- H z a 0 V) Z O V) w W d N cn LJ .� Lli D O Z .- :2�� Q9n _ � r- (D v U C-) O a J p O ccs o LL, F- 0 Q � _ o CL � N N N SHEET TITLE: FRAMING PLAN SHEET NUMBER: PV—A.o3 SHEET 1 OF 1 REV: VOLTAGES INTERCONNECTION: (N) BOLIN PANELS (ON ROOFTOP): - (14 LO.71EN1C41 (1E) 8" EWE PVD DC OPTIM2ERS -1 CIROW OF 8 MODULES AND 1 CIRC:UR OF 10 MODULES or WWI (N) SOLAR EDGE P320 _ OF TIMIZERS ff Ira momallreill—FIRT116pla, (4) #10 AWG THWN-2 (1) #10AWG THWN-2 GROUND (1) 3/4" EMT CONDUIT (N) TYP. JUNCTION BOX: - 4X4, NEMA 3R F � 10 (� ---� (NISOLAREDGE P320___- _ / OPITWIZERS (4) #10 AWG THWN-2 (1) #10 AWG THWN-2 GROIJND - - - (1) 3/4" EMT CONDUIT (3) #8 AWG THWN-2 (1)#8AWGTHWN-2 GROUND-- - - (1) 3/4" EMT CONDUIT (N) NEW INVERTER (MOUNTED INSIDE GARAGE OPPOSITE SIDE OF MSP) SOLAR EDGE 790OA-US 1 DC `.9"Ir ti (E) SUBPANEL (INT. SOUTH WALL): 200A RATED, 240V CUTLER HAMMER LABELED AS PER NEC 090-54 d 880.59 LOCATED INSIDE GARAGE BACK WALL UN GROUNDED TRANSFORMERLESS INTEGRATED DC DISCONNECT L_ (N) 2P 40A / 2P 16 4 QUAD BREAKER USED FOR PV TIE IN 40A I2 N 'i EXISTING (3) 0= AWG THWN-2 (1) MB AWG THWN-2 GROUND (E) MAIN SERVICE PANEL (EXT. NORTH WEST WALL): 200A RATED, 240V GENERAL ELECTRIC L2 N LY ilP'c 2001 ldina I� o 2 3 • xid 4.� C �. _. Cot 1 UTILITY 11"0"- LINE IN Fod ca DC MAX: O 0) co MAX DC VOLTAGE SET BY DC OPTIMIZER 120% RULE (NEC. 12(D)(2) Z \ 500V 10 UTILITY FEED (200A) + TOTAL PV BACKFE:ED (40A) =240A DC OP: DC OPERATING VOLTAGE SET BY DC OPTIMIZER N BUSS RATING 200A X 120% =240A _ _ ( ) -__ (n In _ 350V m - rn � vJ 0- CURRENTS CIRCUIT: UJI U7 w n 18 MODULES & 18 P320 DC OPTIMIZERS WITH (1) DC MAX: MODULE Isc x strings x 1.25 SE760OA-US OVERCURRENT PROTECTION CALCULATION c) .J _ DC OP: � uj opo 0 rn 10.02 x 2 x 1,25 = 25.05A MODULE IMP x strings — 760OW / 240V = 31.6A — � z w z 9.50 x 2 = 19A MODULE Isc x 1.25 x 1.25 — 10.02 x 1.25 x 1.25 = 15.6562A .31.6AX 125% (CONTINUOUS DUTY = 39.5A I(1) 2 POLE 40A OCPD TO BE USED —_ SOURCE Idc_:_ OUTPUT lac: INVERTER lac x 1.25 x INVERTER QTY 1x 1.25 x 31.6 = 39.5A (N) BOLIN PANELS (ON ROOFTOP): - (14 LO.71EN1C41 (1E) 8" EWE PVD DC OPTIM2ERS -1 CIROW OF 8 MODULES AND 1 CIRC:UR OF 10 MODULES or WWI (N) SOLAR EDGE P320 _ OF TIMIZERS ff Ira momallreill—FIRT116pla, (4) #10 AWG THWN-2 (1) #10AWG THWN-2 GROUND (1) 3/4" EMT CONDUIT (N) TYP. JUNCTION BOX: - 4X4, NEMA 3R F � 10 (� ---� (NISOLAREDGE P320___- _ / OPITWIZERS (4) #10 AWG THWN-2 (1) #10 AWG THWN-2 GROIJND - - - (1) 3/4" EMT CONDUIT (3) #8 AWG THWN-2 (1)#8AWGTHWN-2 GROUND-- - - (1) 3/4" EMT CONDUIT (N) NEW INVERTER (MOUNTED INSIDE GARAGE OPPOSITE SIDE OF MSP) SOLAR EDGE 790OA-US 1 DC `.9"Ir ti (E) SUBPANEL (INT. SOUTH WALL): 200A RATED, 240V CUTLER HAMMER LABELED AS PER NEC 090-54 d 880.59 LOCATED INSIDE GARAGE BACK WALL UN GROUNDED TRANSFORMERLESS INTEGRATED DC DISCONNECT L_ (N) 2P 40A / 2P 16 4 QUAD BREAKER USED FOR PV TIE IN 40A I2 N 'i EXISTING (3) 0= AWG THWN-2 (1) MB AWG THWN-2 GROUND (E) MAIN SERVICE PANEL (EXT. NORTH WEST WALL): 200A RATED, 240V GENERAL ELECTRIC L2 N LY ilP'c 2001 ldina I� o 2 3 • xid 4.� C �. _. Cot 1 UTILITY 11"0"- LINE IN Fod ca 'Z 0 O 0) co a] p Z \ 10 CJ 00 z 0 zU) z N (n In CJ a) m m rn � vJ 0- z 0 UJI U7 w n 0 '§2 0 a- c) .J 00 � uj opo 0 rn � U � z w z Of CA �x I � a _ 04 z a 0 In z 0 V) w a% w w f a L0 Z C� Ld O �� w Ca V) Z F Qffiu7 .s (n U D D- ( = 0n U C-)0 LCL- Q U (n _ J Q za ^ w p to I 0 0 C] N C, N SHEET TITLE: SINGLE LINE DWG SHEET NUMBER: Pv-EOI SHEET 1 OF 1 REV: N' k (A 00 N rn w W z w U J A I RON RI DGE Simplified Grounding Por Grpnter ,Safety & Lower Cont Traditionally, solar modules are grounded by attaching lugs, bolts or clips to the module frame, then connecting these to a copper conductor that runs throughout the array. This process adds time and cost to the installation, and often results in improper grounding, creating significant long-term safety risks. The IronRidge Integrated Grounding System solves these challenges by bonding modules directly to the mounting rails. This approach eliminates separate module grounding hardware, and it creates many parallel grounding paths throughout the array. providing greater safety for system owners. 2 Grounding Strap Grounding Straps are used to I bond rail -to -rail connections They are only required on the rad with the grounding lug. Integrated Grounding System Grounding Mid Clamp Each Grounding Mrd Clamp pierces through the anodized coatings of both the module frame and the mounting rail to form secure electrical bonds, which are repeated throughout the array 3 Grounding Lug A single Grounding Lug connects an entire row of PV modules to the grounding conductor. Installation Overview Install Roof Attachments • Install appropriate roof flashing and/or standoff for roof type. • Attach L -Feet to flashing or standoff. Prepare Rail Connections • Insert splice into first rail. then secure with Grounding Strap and self -drilling screw. • Slide second rail over splice, then secure with opposite end of Grounding Strap and self -drilling screw. Mount & Ground Rails • Attach rails to L -Feet and level rails. • Install one Grounding Lug per row of modules. • Connect Grounding Lug to grounding conductor. Install Modules & Clamps • Install first module using End Clamps and Grounding Mid Clamps. • Install additional modules using Grounding Mid Clamps. • Finish row with a second pair of End Clamps. Testing & Certification The IronRidge Integrated Grounding System has been tested and certified to UL 2703 by Intertek Group plc. UL 2703 is a proposed UL standard for evaluating solar module mounting and clamping devices. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. The testing process closely mirrors that of UL 1703, the solar module testing standard, including temperature and humidity cycling. electrical and mechanical load testing, and manufacturing quality reviews. Module Frame Compatibility Dimension Range A 31.Omm - 51.Omm B 5.08mm (minimum) Any module frames whose parameters are not listed in the provided table have not been tested for compatibility The Grounding Clamp has proven robust in grounding 60.Cve,Il 72 -cell solar module frames wi uction and a rf�ct ERs 11 anodization thicknesses. ,� t�J�IGing Doper lull7 All solar modules listed to UL 1fwith frame construction within the parameters stated a g compatible with the, IronRidge Integrated Groundtn _. - REVIEWED FON GOOGC NIPLl Reviewed By In O al o '0 to � 0ai p a (n r7 cJ zy L0 o) M z w w o F W z p� o 10: ci a. _J ao L.Li 00 U f t� Z L,J Ol_- i Q W O T N t— z Q V) z O W 0_ w a: 0 rn p zLLJ O Z oo O to Z :2V)o Qg� (L ILL U U Y 0)o (/) IZ J o O co W0 to ~ O CIDa N N N SHEET TITLE: GROUNDING SPECS SHEET NUMBER: PV—DO5 SHEET 1 OF 1 REV: PER NEC 690.17(4) PER NEC 110.27(C) & OSHA 1910.145 (17(7) 39A 240V PER NEC 705.12(D)(4) & NEC 690.64 PER NEC 690.5(C) PER NEC 705.12(D)(4) & NEC 690.64 CAUTION: SOLAR CIRCUIT J PER NEC 690.31(E)(3) & IFC 605.11.1.2 PER NEC 705.12(D)(4) & NEC 690.64 �. ? " C`:PcRs `IN0 " Pu;Iding D partment FEB 212016 RE`'IEWED FOR CGDE COMPLIANCE Reviewed By .��" •�7RT� w Z O m Z °° N = \ s ccq ino J OD 0 N m Z 0 } W v � m Ww > O Z W N O Z per, 0 d Q D LZL0 co O W co:D'I- h- V) 0) `} Q U O Z O Q = W O Lr) C.L N z Q 0 V) z 0 V) w W 0 o z °'Ld o z W z z o 0 Q a I _ r LL- U O o Y Ln J 0 .. O tD n 0 a w O 'n Q o= o � � 0 N N N SHEET T1TLE: SIGNAGE SHEET NUMBER: Pv—O1 SHEET 6 OF 11 REV: it LG NeON" 2 EMMU Y) z LG ... . 03 Life's Good Of < T_ Mechanical Properties Electrical Proper -ties (STC 0 rn C4 .cells 6x10 Module Type 315W (D ._J 0 a)ED Cell Vendor t G MPP Voltage (Vmpp) 33.2 W re) — Cell Type_. MPP Current (Impp) 9.50 �J ;� 0 Ir Cell Dimensioits. 15675x156J5mm/6inches Open Circuit Voltage (Voc) 40.6 M z of Busbitr 12 (%Ai Wife Busbal) Short Circuit Current (Kc) 10.02 0 of 0 Dimensions (L x W x H) 1640 w 1 !q - -r 64.57 x 39.37 x 1.57 inch Module liffitiency Operating Temperature (IC) 19.2 _46 - -go 21 ul korrt Load 6000 Pa 112 5 Wf­* Row Load 5400 Pa 13 psf Maximum system Voltage M Maximum Series Fuse Rating (A) 1 0()r .--- willeight 17.0.t 0.5k9/37.48:t 1.1 Itis Connector Type MC4, MC4 Compatible, IP67 JwIctiom so IP67 with 3 Bypass Diodes Length of Cables 2 x 1000 mm 12 x 39.37 inch Glass High Yransmiss*n Tempered Class Frame Anodized Aluminum Power Tolerance 0-3 JW0W/,VU0dL*Tan,.;1n,_25-C. • nir n,..om p., w ; rnas. " iiiiii. , r*4 by I r i wcron� at ft NW and &6.Ait. awrr,­ AMIS Electrical Properties (NOCT*) (L Certifications and Warranty Module. Type Maximum Power (Pmax) 315W 230 00 LLJ 00 O ur) Certifications IEC 61215,117C 61730-1/-2___ MPP voltage (Vmpp) 30.4 Z 0 LJJ LG IEC 62716 (Ammonia Test) IEC 7 1 (Salt M;st Corrosion Test) MPP Current (1impp) Open Circuit Voltage (Voc) 758 31.6 Short Circuit Current (Isc) 8.08 Module Fire Performance (USA) Type 2 (UL 1703) LG's new module, LG NeONI 2, adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires APPPOVFr, PFK)MA7 to enhance power output and reliability. LG NeON'w 2 demonstrates LG's efforts to increase customer's values 60 cell C E 0 - vv beyond efficiency. It features enhanced warranty, durability, Intem* performance under real envir environment, and aesthetic design suitable for roofs.VOC Fire Rating (for CANADA) Class C (ULC/CRD C1703) Product Warranty 12 years 0 __ ___ � .......... Output Warranty of Pmax LrvarwarTanty' rir, IS%, 2) Af�­`,il y,., 0 6%p &q,.dalor, 3)83 6% fix 25 r.,, Temperature Characteristics NOICT 46:L 3 *C Pmpp -0.38 XrC -0,28 %/*C.-- Dimensions (mm/in) Isc 0 03 %/*C Enhanced Performance Warranty High Power Output LG NeCN' 2 has an enhanced performance warranty. Compared with previous models, the LG NeCIN^" 2 Characteristic Curves loom .^a 16-1 The annual degradation has fallen from -0 7%/yr to has been designed to significantly enhance its output -0.6%/yr Even after 25 years, the cell guarantees 2.4%p efficiency, thereby making it efficient even in limited space more output than the premus LG NeONI modules. Aesthetic Roof Outstanding Durability LG NeON'" 2 has been designed with aesthetics in mind; With its newly reinforced frame design, LG has extended allow 400 .. can 1,00 t5ov logo Me woo ]OX W 6100 Co L RTI 3U,ding . . . . . 20 thinner wires that appear all black at a distance. the warranty of the LG NeON" 2 for an additional The product may help increase the value of 2 years. Additionally, LG NeONTI 2 can endure d front a property with its modem design. load up to 6000 Pa, and a rear load up to 5400 Pa. 0 REVIEWE 0 E COMPLI • Better Performance on a Sunny Day Double -Sided Cell Structure En L G NeON- 2 now performs better on sunny days thanks the rear of the cell used in LG NeGN— 2 will contnbutp. to to its improved temperature coeffictency generation, just like the from. the light beam reflected fmm the rear of the module is reabsorbed to generate a great amount of additional power 40 20 D 0 5 About LG Electronics North America Solar Business Team Product spectications are subiecl to change without notice. (8 LG LG Flectrumcs U S A, fm DS -N2 -60-C -G-F- EN -504 27 ufes Gow 1000 SyNan Ave, Fnglewood Cliffs, N) 0 1632 Copyright 0 201 S LG tiftimws, Ail ngm% rpsmod, co -tact iquilArCoNge(On 01/04/2015 ww*1irsclarusacom kaaxation for a Witter Lo. LG EiectDr<s,s a global player who has been committed to expanding its capavty, based on solar energy b,%�ness as its M,re growth engine We embarked ci^ a solar energy source research program in 1985, supported by LG Group's rich expeierice in sem;-condurtci, LCD. chems" and materials industry. We successOully released the first Mono X9 series to the market in 2010- wt o- were exported to 32 co,,nt,raism the hollowing 2 years, thervaltet. In 2013, LG NrMl (iwriosly known as Mo -o X* NeM) wor'ntwsc&, Award' %Pwl proved LG lis the leader of ­uvirtlan in the r,d,,%-,y. LL it Y) z 03 Of < T_ to — "i, 0 rn C4 Z C*4 c14 I'll (D ._J 0 a)ED 0 z C14 W re) — C14 0) Z 9 �J ;� 0 Ir ul) C14 0) :4k M z W z W UJ (A 0 of 0 X Lij z 21 ul L) (L _J 00 LLJ 00 O ur) CI) < C) Z 0 LJJ < V) 0 Q_ V) Z 0 En 5 LLL LL >1 C. LLJ X lent to z 4M F_ :2 0 z Lli NZ C; 0 z — V3 0 g U-) CL 0 C) 0 < 0 > LLi C) 117 > 0 < X Of 0- to 0 cli (14 cli SHEET TITLE: PV MODULE SPECS SHEET NUMBER: PV -DO 1 SHEET 1 OF 1 1 REV: !/I rn Ol solar ' • • solar " • • SolarEdge Power Optimizer F 00 ca Module Add -On for North America Ir) P300 / P400 / P405 \ SolarEdge Power Optimizer W V) Z N P300 P400 P405 in Module Add -On For North America INPUT (for 60 -cell modules) (for 72 & 96 -cell modules) (for thin him modulesi 0) �k M Rated Input DC Power"` 300 400 405 W w P300 / P400 / P405 • Absolute Maximum Input Voltage (Voc at lowest temperature.) 48 80 125 Vdc LiZU) — MPPT Operating Range 8-48 8-80 12.5-105 Vdc 'D O Uj Maximum Short Circuit Current (Isc) 10 Adc CL Maximum DC Input Current 12.5 Adc LLJ 0000 Ln rn Efficiency 99.5 % z LLI LJ Z _Maximum Weighted Efficiency 98.8 % 0 In CL N Overvoltage Category 11 00K OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc ` Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE Z EMC FCC Partly Class B, IEC61000-6-2, IEC61000-6-3 O •4 w'i' Safety IEC62109-1 (class II safety), UL1741 (1) �A5 leafs RoHS Yes W a Watran�'1?s INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Pxxx-2 series 141 x 212 x 40.5 / 5.55 x 8.34 x 1.59 mm/in Dimensions (W if L if H) Pxxx-5 series 128 x 152 x 27.5 / 128 x 152 x 35 / 128 x 152 x 48 / mm/in 5x5,97x1.08 Sx5.97x1.37 5x5.97x1.89 0: r l Pxxx-2 series Weight (including cab`es)g Pxxx-5 series 950/2.1 770/1.7 930/2.05 930/2.05 r / lb gr / Ib Input Connector MC4 Compatible 1 W ° Output Wire Type / Connector Double Insulated; MC4 Compatible Z- L0 (n U � o Output Wire Length 0.95/3.0 1,2/3.9 m / ft o Q rn Operating Temperature Range Protection Rating Pxxx 2 series -40 - +85 / 40 - +185 IP65 / NEMA4 SP / is Lyr W OO Ln O Pxxx-5 series IP68 / NEMA6P/" Relative Humid;ty 0 100 f+ t ` Rated STC oower of the module. Module of up to •S% Dower to'e+a�ce a:.•wed Funding Depa 1,4, % f� a- IAC PV SYSTEM DESIGN USING A SOLAREDGE INVERTER' SINGLE PHASE THREE PHASE 208V THREE PHASE 4$OV N SHEET TITLE: Minimum String Length ` REVIEWED SUR CODE ODE COMPLIA PV -D02 PV the REV: (Power Optimizers) 8 10 ] 8 Reviewed $y' power optimization at module -level Maximum String Length - Up to 25% more energy (Power Optimizers) 25 25 Maximum Power per String I 5250 6000 12750 W - Superior efficiency (99.5%) Parallel Strings of Different Lengths - Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading or Orientations Yes —Flexible system design for maximum space utilization 1)'t is not aiiowed to mWJ ix PWS with P300/P4WPGPxxf in one string, — Fast installation with a single bolt - Next generation maintenance with module -level monitoring - Module -level voltage shutdown for installer and firefighter safety !/I rn Ol F 00 ca C14l Ir) Z \ D W V) Z N c4 in 0 0 04X 0) �k M Z a; w 0L LiZU) 'D O Uj CL D 00 LLJ 0000 Ln rn � � U z LLI LJ Z Of V) N �I �1 � 0 In CL N H Z Q O U) Z O (1) W X w 0: .r Z Li 1 W O O Z- L0 (n U � o _ 5- U U o Q rn O C� W OO Ln O C, f� a- IAC C, N cV N SHEET TITLE: INVERTER SPECS SHEET NUMBER: PV -D02 SHEET 1 OF 1 REV: solar -••: SolarEdge Single Phase Inverters For North America SE3000A-USI SE380OA-US / SE5000A-US / SE6000A-US i SE760OA-US / SE10000A-US / SE1140OA-US ��verrej 25 m 12Qats ` �� vJartant'1 if i 0 The best choice for SolarEdge enabled systems + Integrated arc fault protection (Type 1) for NEC 2011690. 11 compliance Superior efficiency (98%) Small, lightweight and easy to install on provided bracket Built-in module -level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only Pre -assembled Safety Switch for faster installation Optional - revenue grade data, ANSI C12.1 solar - - single Phase Inverters for North America z. SE3(, a -US / SE380OA-US / SE5000A-US / SE6000A-US SE760OA-US / SEt0000A-US / SE1140OA-US SE3000A-US SE380OA-US SESOOOA US SE6000A-US SE7600A-US SE1000OA- US SE1140OA-US OUTPUT Z Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V .... 0 00 10000 , I Max. AC Power Output ' 3300 4150 6400 @ 208V 6000 8350 10800 @ 208@240VV . ........ . 5450 @240V. 10950 @240V, AC Output Voltage Min. -Nom. -Max.") �.......... O 183-2178-229 Vac (W .... 04 AC Output Voltage Min. -Nom: Max j1) o y- Y 211 240 264 Vac 0) �k M f AC Frequency M n.-Nom.-MaxP1 ) . 59.3 - 60 - 60.5 � (wfthHl country setting 57 - 60 - 60.5) Max. Continuous Output Current ` 12.5 16 24 @ 208V I 25 32 48 @ 208V {... 0 O 21 @ 240V { 42 @ 240V GFDI Threshold I IY ZUJ o 1 a Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT c) Maximum DC Power (STC) I 4050 5100 6750 8100 10250 13500 Transformer -less, Ungrounded I Yes ©00 LLJ Max input Voltage I Ir U 500 Z Nom. DC Input Voltage z Q Cy 325 @ 208V / 350 @ 240V Max. Input Currenti" I 9.5 13 16.5 @ 208V 18 23 33 @ 208V 15.5 @ 240V 30.5@ 240V Max. Input Short Circuit Current. ....... ..... .. ................ 45 Reverse -Polarity Protection I Yes Ground -Fault Isolation Detection I Q 600ku Sensitivity Maximum Inverter Efficiency I 97.7 982 98.3 98.3 98 98 CEC Weighted Effie ency 97.5 y8 97.5 @ 208V 97 5 97.5 97 @ 208V 98 @ 240V 97.5 @ 240V Nighttime Power Consumption ; < 2.5 < 4 ADDITIONAL FEATURES Supported Communication Interfaces V) R5485, R5232, Ethernet, ZigBee (optional) Revenue Grade Data, ANSI C12.1 W Optional"' Rapid Shutdown - NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installed' STANDARD COMPLIANCE Safety UL1741. UL1699B, UL1998 , CSA 22.2 Grid Connection Standards IEEE1547 Emissions FCC par,15 class B INSTALLATION SPECIFICATIONS 11400 VA 12000 VA .. H7 47.5 P A I.. A yes 15350 I W Vdc Vdc 34 5 Adc Adc 98 % 97 5 % W AC output conduit size / AWG range 3/4" minimum / 16 6 AWG 3/4" minimum / 8-3 AWG DC input conduit size / q of strings / 8 3/4" minimum / 1 2 stringer _- 3/4" minimum / 1-2 strings ! 16-6 AWG (`4 AWG range 1at1 14-6 AWG / Dimensions with Safety Switch �slt'"°a .5 x 17.5 x 10.5 /, �� ,.1�t in/ n r �y,., (H%WMD) 30.5 x 12.5 x 7.2 / 775 x 315 x / �++ ! 775 x 315 x 260 8,u*,*Idi +II@rraev I t� ! .i Weight with Safety Switch 51.2 / 23.2 54.7 / 24.7 {.� 88A / 40.1 Ib / 4 Nat .t conve Cooling Natural Convection and n of q(user repiaabi�} fan (user replay"EVIEVVED FUR CGU CUMPLIAN Noise <25 < So d Min. Max. Operating Temperature ,Range 13 to +140 / 25 to +60 (40 to +60 version availabRo Vlewe-) By ATS Protection Rating NEMA 3R 11' For other reg anal set nip pkat* contact SoiarFdre WPOolt '4 A higher current source mar be used, the inverter *A s;m;t its input current to the values stated. 1r19everrue grade leverter P/N: %*=A-USMNNI12 (for 760OW Inv*ntv.SE760eA•US002NNR2). Rapid sh ldown krt P/N: SE1004RSD51. -40 vrrsbn P/N SEnouA US000NNU4 (ra• 7600W irnerter.SE760DA-USt102NNU4) Z B] to 0 00 C14 S u) I If) N O (W M 04 o y- Y u^y v 0) �k M W y g Z I-Zil Ij 0 O IY ZUJ o 2. a c) ©00 LLJ Lo Ir U Z (] LLJ z Q Cy (1fW J t1i 0�x C 0- N F - Z Q Z O V) W W Z C] � O �' LJ o to Z Z C> Q Uj C] _ t\ n U U o Q � � J LJ O In / ~ 0 C] Q CL c0 C, N N N SHEET TITLE: INVERTER SPECS SHEET NUMBER: PV -D02 [SHEET 1 OF 1 REV: IRONRIDGE Solar Is Not Always Sunny Over their lifetime. solar panels experience countless extreme weather events. Not just the worst storms in years but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. Compatible with Flat & Pitched Roofs XR Rail Family Force -Stabilizing Curve Stoped roots generate both vertical and lateral forces on mounting rails which can cause them to bend and twist The curved shape of XR Rads is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. XR Rails are IronRidge otters Compatible with o range of tilt leg FlashFoot and options for flat other pitched roof roof mounting attachments. applications. li Corrosion -Resistant Materials All XR Rads are made of marine -grade aluminum alloy, then protected with an anodized finish Anodizing prevents surface and structural corrosion, while also providing a more attractive appearance Ito XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. XR10 XR10 is a sleek, low profile mounting rail, designed for regions with light or no snow. It achieves 6 foot spans, while remaining light and economical 6' spanning capability Moderate load capability Clear anodized finish Internal splices available Rail Selection XR100 XR100 is the ultimate residential mounting rail It supports a range of wind and snow conditions, while also maximizing spans up to 8 feet. 8' Spann ng capability Heavy load capability Clear & black anodized finish Internal splices available XR 1000 XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans 12 feet or more for commercial applications. 12' spanning capability • Extreme load capability Clear anodized finish Internal splices available The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria: ASCE 7-10. Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.c:om for detailed span tables and certifications. KS XR10 XR100 XR1000 •-�'- C,iPL, I �w Building a.� y Ti ; LP s '� RE -VIEWED FOR CODE U Reviewed By: , p:l IN 120 None Z 140 a1 160 Q 100 120 10-20 CJ 140 04 160 100 30 ZN 160 100 40 a) 160 50.70 160 80-90 160 XR10 XR100 XR1000 •-�'- C,iPL, I �w Building a.� y Ti ; LP s '� RE -VIEWED FOR CODE U Reviewed By: , p:l IN Z O a1 Q CD z, O CJ 04 1 ZN a) O Z to M CJ Z r (Y uj v Oi M W O til U7 a F tI Z ` w U Q } � _J 00 L.Li 00 Cr U ED O = Q W o D_ 04 tV f - Z a a Z O En w It W W O in U Li0 H � Z w Z z o j c~n , ,s V Q g Lr) o _ � r O U c 0_ ^ - w0 tri > FI O Qt�C tcOD � N N N SHEET TITLE: RACKING SPACES SHEET NUMBER: PV-DO3 SHEET 1 OF 1 REV: E -Mount Lag I QMSE - LAG THIS EDGE TOWARDS ROOF RIDGE ITEM DESCRIPTION OTY./BOx No— I FLASHING. 4 x 17 x .010'. SIM, WILL 1 2 Q11LOCK. CLASSIC, A360.1 CAST AL, WILL 1 i 3 �4 PLUG, SEAUNG. 5111V x 719", EPOM / 16-8 SS 1 _ LAG SCREW, HEX WAD. 5/16'• S-1/2-. 164 SS 1 5 WASHER_ FENDER, 5/ 16.10x1 -1/l Do. 16.6 SS 1 o --- Quick Mount Pv rr,E. AVAILABLE IN MILL. AND QMSE-LAG: QMPV E-MOUNT WITH LAG BOLT BRONZE ANODIZED FINISHES SUE oenv,+16. RAD REV ranwrxa A !)ALE: 2/2l7oif 3 2 KIM P10F.11101101 Lag Bon Spec" rations _—.._ __-- sp.oec cma d+e- re vrr 2- ryya e•� s',e- •vs Pr +'swa e•Pn tso,gw F v, lr«n x rsa 796 po.4-Fr, S.* t M 1 706 736 C nas'r.rr 6o^+r+. -aypo. P-7 LVSR 16 i a"w� .e !oi 175 _F _.—..--------'--- '— 43 ex— 7.2 wn.r.iNON; .e 706 i 236 s> , oyr. Fr .2 els t .206 S— 4w Fe LE W 2 +,.am. P>w •rd rgew 6-w d A6R roc MC.! 5C 166 296 sera•ec Am•rWn Wale Counts. NOS 20os. Table 11.2 A 11 3.2 A kl.m: I (Thread ^ 1 be embedded,n a rifer or other stvctura rod'Wr- v 21. sea NDs laMe t I.s.IC for rpwred edge ehtanen 817.2.3.31 Ouick Mount Reference and Tips Proper , Flashing Placement 6hRs fwt r�moveel. - Keyway atlows wMer emry. �eelNae � rllollaura/eeats 7•eaaliw saurtwiaaon can twa.re.6 Additional tips and information for installing mounts: • See Quick Tips videos on nail removal, and more at: http://www.quickmountpv.com/support/videos.html • It is not necessary or advisable to use nails or other fasteners to secure the perimeter of the flashing. • The E -Mount is made to work with standard and high-definition composition/asphalt and wood shingle roofs with 5" to 5-5/8" courses. If the exposed surface of the course exceeds this measure- ment you may need to use our Classic Shake Mount instead. • Depending on the season and climate, size and location of seal tabs, and quality of the shingles, the seal tabs that adhere the shingle courses together may not effectively seal the shingles to the flashings. If this is the case, simply add several quarter -sized dabs of manufacturer accepted sealant or asphalt roofing cement, meeting ASTM D 4586 Type 11, between the flashing and the shingle above. • Mounts should not be installed in areas of the roof susceptible to ice damming. Water ponding un- der the shingles can reach the bolt penetration. • Take care not to damage the roofing material while working on the roof. Removing stone granules and deforming the shingles in any way can shorten the lifespan of the roofing. The value of the solar array is directly affected by the condition of the roof it is attached to. Mal r-201 S, Rev 3 I 1117./_3 it Mar 1015, Rry 3 E -Mount Lag Installation Instructions Installation Tools Required: tape measure, roofing bar, chalk line, stud finder, caulking gun, sealant compatible with roofing materials, drill with /i32" longstylebit, drill or impact gun with 1/2' socket. • • • we • •• • • • • • •- -• • • • • • -r Locate, choose, and mark centers of rafters to be Carefully lift composition roof shingle with roofing Insert flashing between t st and 2nd course, Slide mounted. Select the courses of shingles where bar, just above placement of mount. Remove nails up so top edge of flashing Is at least 3/4' higher mounts will be placed. as required. See 'Proper Flashing Placement' on than the drip edge or the 3rd course and lower neat page. flashing edge Is above the drip edge of 1 st course. Mark center for drilling, Using drill with 7/32' bit, drill plot hole into roof Clean off any sawdust, and fill hole with sealant Slide the Trashing into position. Insert the rubber and rafter, taking care to drill square to the root compatible with roofing materialsplug into the 09lock cavity. Do not use mount as a drill guide. Drill should be ':org style bit: aka aircraft extension bit'to drill a 1 W deep hole into raker. Slide the washer and the L -foot (not included) onto Using a 112 inch socket on an impact gun drive the lag screw. the lag screw until the ClSock stops total easily. DO NOT over -torque. BI 7.2.3 31 Ma, 2015, Rev 3 't t?J:Iding DuGer l FE � - 2016 REL-VIEVVEO FOR GODS COMPL AM Reviewed By' j� harA V) to O M 'o o N _ \ O N O V M co N r In Ct) M W Z LLJ W In Z Z Li CIL O M U CO O LLJ CO 0) U Z O LLJ i. - UJ Z = < �~ O In CV z Q V/ Z O W W IY d 0 o Z Q Z LLJ Z Z O D 0 >_ Q Lo _ n O O o; Ui a -Y J r` Oco zd o LLJO to >v �o Q o= o co N N N SHEET TITLE: ATTACHMENT/FLASHING SPECS SHEET NUMBER: PV— D0 - SHEET 1 OF 1 REV: - A -) MAJ (CUPIEKTINO EI:PA-Nft U-NNERCWTIFICAtE OFCOMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT z, BUILDING DIVISION 10300 TORRE AVENUE - CUPERTINO., CA. 95014-3255 '(408) 777-3228 a F.AX- (408) 777-3333 i buildinc0cupertho.orci It 41mmmo— f A-15ml PERMIT CXN-N OT BY, 1r4NiUjrbDAND -Cog plU ,TEI) UNTIL THIS Cr, qtTWECATU This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Ahari�s I for compliance with 2013 CRC Section R,314,2.013 CBC Sections 420.6 and 907.2.11.2 where no interior. access for inspections are required. GtNEHAL INFORMATION Existing Single-family and multi -family d�Mlings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of: additions, alterations, or repairs to existing dwelling units exceeds $-1000-M CRC Section, R-314 and CBC Sections 907.2.11.5 and 4-20.6 require that Smoke Alarms andyorCarbon Monoxide Alarms b- e irts-ta Ue d in L the f o116 : whag locations: A)it V,A, SA&CrKE AILAIRM77" C G A, t AR, MA Gutgld-e of, eachtseparate sleeping area in the immediate vicinity of the X bedsaofn(g) On every level of Et dwellb�-g unit incliiding basements X X Wiffi ffim eacf-,i, sleep-!p1room X Carbon Monoxide all -arms. are inotrequired in, dwellings which da Rut cOnt'a m— fuel 1>UFnnlg. appliances andthatdot not Dave aniatt,a-chedigarage. Carboa:manoxide alarms combined with smoke alarms shall comply with CBC Section 42G4and shall be' approved; by the Office of the State litre Mar Fower S ha dwdqzq ura#,s wiffi TL Lo cav=ercial power supply, allarm(s) May be solely battery operated. 1nexisChdwellmmunfts; alaxms areP e4mitte d to be solely battery operated whi e re repairs ar: Jeratju sdoY not resv& in, the removal of wa-111 mid cei.-H % fishes ox there, is., na aae&& by mw ie2aas- of atfic, basement ,enit orm OXaw1 vee, Refer' toCC Sections 14 ad CC Sections. an420�6- AnlecricalperHatequited for - F' 1 alanw, wluk h-, M- uisit We C led, to, ffinebvAlding. wir&!& Asowm'oitk,ea'b-,@v,e-r,ef,eyel,i,ce(ilpro pet,y, lherebyc has/havebee plilarwie and The 4, aTimmahawe- Beemittlested and a%eoperatkanalk azord the, date slpedl Snzak, dk rayj;ye&U3gp8,1j,!*- address A '2-7 W - XTER-CONSW tV ING P-LUMBING, FIXTURES .2 OWNERCERTIFICATE OF COMPL-tiANcE OMMOR TY �DEWWMMEWIUEPARTUENT - BUILDIM DIVISION 10300 TORRE AVaJUJE -'G UERTIND. CA -9M 4=3255 TIM 1TR-32-28*FAX(,4U8) 7,7,7-333-3-buildinc(a-?cuu--&-lio.o fW P.,-rmm A N Is your real prqprertyaqp-�r ht oredhistoridi site? 11 yes Civil Code Sections 1101.1 througli'1101.18 do not apply. Skip therestof the form and sign bottom of form. MNo Go to Question 2. 2. Does your real property have a licensed pluMbelr certifying that, due to the age or configuration of the property or its plumbing, installation lof water -conserving plut6bing fixtures is not technically feasible? El Yes Civil Code Sections 1101.1 thrbugh','- -1101.846not apply. to The -licensed plumber's certification has-been provided to the Building Division. Slap the rest of the form. and sign b4ttom of fb= 5' No Go toQuestion 3. 3. Is water serviedpenrm -ently disconnected for yourbuilding? F1 Yes Civil Gide Sections 1101.1 through 1101.8 do riot apply. Skip the rest of the form and sign bottom of form. No Go to Question 4. 4. Is your real propertybuilt and available foruse of occupancy oftorbefore January 1, 19941 0 No My real property is built and available for tee or occupancy after January 1, 1994. Civil Code Sections 1101.1 lfirb-UO, 110111 donutapply. Skip the rest of ffie form and sign bottom of form. M,lg Yes Myreal property is built and available for. use or occupancy.on or before ]a nuuy 1, 199`4 Civil. Code; Sections. 1101.1 thoughl1011 apply. Check one of the three following statements and sign bottom of form. 5, Please check M of tyre- fallowing, 0 P&O 96-C.; Civil. Code Seetion 11011..4. 0A amid after, lanwaty L. 20141,, building ailt�a-fio- as, cit improvements pro-vernents shall require all nouwcoxnvfiant Flumbing. fixtures tube libudd-mg. gnedrbdfbre January 1, 2017, all non- conTfiam placating fixtures- shall be fepfadedf with, grater conserving plusaffigg liktures (regardless of whether property m6rgeeg alterations or' imipfavefneuu), 0 MypfGperty-i&e�rnttltlfafnityresidential realiptogaity866 Civil Code Section 11015, Onm- daffier January 1, 2614,, or improveffimts, shaff, requ e non- compliant plumblvg, fixtures to, be replaced withi vvater=ddngeiviftgplb mbing fixt ures-. On or before Ja nmry 1, 2919;, alf(nen-co mpriantplug6mh ig, flixturea Adf, be, replaced wiffi water - Conserving plmnbing fixtureg• tharmig-kou, tithe b A& ft (regardilas, of whedierproyeitywdi-trgoes, alterations or knproveme9l's). - i 3 E3 My property is a commercial real: Ptopert-Y, ij, S"cer, Civil CT'646 Section 110,1.5. On and after January 1,, 2014,; specified bu.Odiqlg, aftermflonz or improvements shall reguffhe non- .compliant polun-ffing, fixtures to, be replaced, with wator-conservilig p in fixtures. On or bidiem Yanuary, % 2019, all non:—compliant. &itking fixtures shall be replaced with, water'- emaserwgilg. of fiether property uftdergM or inTre 1,, as the owner or owner"S. agpnd Of this, property'.;, eertify URder penalty of per ing jury that, Hort plant prh m bm -.. fixtures: wiffbe. rep-Baced pflor to. 65a -ft. sp ucifivdt above=wlffi,w4ler-cqns m—Ing plumbing fktures in, aceordm-z e withUWAt Cede S. eotionas 110`1..1 i California Codb,and manufacturm's, iiistaRafion req a -ad that tfit water- eons er, ving pjunaffiring factures comply w, Rh the requirements, as, indicated in the taBle, on,tie fallrowin-a raze'. Owner ©>; 0WRevA1_qgnYs, Upon! e o m p fe On g andi s iggiiig. this C edifie aft,, p Nasf, r, etumn 1 t ta th e, B uRA i a g Di As i o a im. @ rde v ta, finall youry b- ull din g perm -4 S,B4R720T'5.d6c revtse-d, oslmliu,