Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
15090010
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10775 WUNDERLICH DR CONTRACTOR: FOUR SEASONS PERMIT NO: 15090010 ROOFING OWNER'S NAME: IAN GERBODE & SARA -JANE SKIWSKI PO BOX 1668 DATE ISSUED: 09/01/2015 OWNER'S PHONE: 6508058588 SAN JOSE, CA 95109 PHONE NO: (408)278-0330 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL REMOVE (E) TAR AND GRAVEL AND INSTALL License Class Lic. # ',"7 Z /o _ CERTAINTEED _ V--_, ;r /Datep BUILT UP ROOF SYSTEM (1600 SQ FT). Contractor /` r .S/ 1 hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $4800 erformance of the work for which this permit is issued. have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 37529006.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 DAYS FROM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, J costs, and expenses which may accrue against said City in consequence of the Issued by: G Date: granting of this permit. Additionally, the applicant understands and will comply `! with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date / RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature ofApplic Date: r /_J_ I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will 1 hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Mu ' ' al Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 255 5 33, and 5534. Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Owner or authorized agen Date: / I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, ARCHITECT'S DECLARATION costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date CUPERTINO REROOF PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildingQcupertino.orq PROJECT ADDRESS 10-77Si APN # OV,INER NAME �7 j r�G �r PHONE E-MAIL 55 STREET ADDRESS _ I CITY TATE, ZIP FAX Y�G�A 7 r7 (V ! • CONTACT NAME PHONEE-MAIL _ o - P15 — S%_J 2 .w! e►�w! l 6-5 STREET ADDRESS e� n CITY, ;T TE, ZIP FAX s y ❑CONTRACTOR 13 OWNER El OWNER -BUILDER LS 0111ER AGENT E3 CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT COM OR NAME /� p �Z LICENSY-NUMBER LICENSE TYPE BUS�iLtC.ff 3 Z 3 COMPANY AME rY rim E-MAILFAX C c�c�t.Z �S fobs/. 2L r� U f3 — 2 STREET ADDRESS CITY STATE, ZIP rte— t i PHONE 19 0 —Z 7,:v 0 se �-ii ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC. # COMPANY NAME Z� E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF FD or Duplex ❑ Multi -Family ROOF AREA: VALUATION: Commercial STRUCTURE: EXISTING ROOF TYPE: LT BUILT-UP ROOF ❑ ASPHALT SHINGLES ❑ WOOD SHAKES ❑ WOOD SHINGLES ❑ OTHER (SPECIFY) REMOVE REPLACE L7YES IF NO, PLYWOOD ❑ '/:" ❑ PLYWll 11 OSB [PITCH: ROOF ❑ No # L.AYERS: 1 THICKNESS: ❑ 5/81, TYPE: ❑ CDX :12 CLASS: A PROPOSED ROOF TYPE: '— BUILT-UP ROOF ❑ ASPHALT SHINGLES ❑ WOOD SHAKES ❑ WOOD SHINGLES ❑ OTHER ICC -ES REPORT # DESCRIPTION OF WORK: 4 ��_� ..e /� � � enc ` .vrz✓ By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building c tr n. I aut orize representatives of Cupertino to enter the above -id ified roperty for inspection purposes. SignatureofApp] icant/Agent: Date: �� SUPPLEMENTAL INFORMATION REQUIRED If building is associated With a Home Owner's Association, provide letter = PLAN CHECK TYPE `' RovruvcsLiP ovEx Ta>rcoiJtyTEx PI AN REPIE�V of approval from HOA. Provide Planning approval to verify if there any restrictions. ti kBUiLDI1�G ❑ `r EXPRESS , PIANNII�GPLANRE«Ew Provide copy of Manufacturer's Installation Specifications. ❑ STANDARD ❑ FIRE DEPT -_ Provide signed copy of Cupertino's Tear -Off Policy. q ❑ oTHEx — ReroofApp_2011. doc revised 03/16/11 CITY OF CUPERTINO FM_7 FEE ESTIMATOR - BUILDING DIVISION LIM ADDRESS: 10775 WUNDERLICH DR DATE: 09/01/2015 REVIEWED BY: SEAN gmN APN: BP#: 'VALUATION: 1$4,800 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY USE: SFD or Duplex 1,/11701. Insp. Fc, PENTAMATION PERMIT TYPE: 1SFDWLR00 WORK REMOVE E TAR AND GRAVEL AND INSTALL CERTAINTEED BUILT UP ROOF SYSTEM 1600 SCOPE I SQ FT). NOTE: This estimate does not include fees due to other Departments (Le. Planning, Public Works, Fire, Sanitary Sewer District, School District. etc). These fees are based on the nreliminary information available and are onlv an estimate, Contact the Dent for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff' 711113) Mech. Plan Check Ph1n1b. Plan Check Elec. Plan Check Meeh. Permit Fee' Plumb. Permittee: inter Permit G. • Other,ilech. Insp. Other Plumb Insp.Li Other Elec. Insp. i?ech. Insp. F", 1,/11701. Insp. Fc, le c. Insp. Fee: NOTE: This estimate does not include fees due to other Departments (Le. Planning, Public Works, Fire, Sanitary Sewer District, School District. etc). These fees are based on the nreliminary information available and are onlv an estimate, Contact the Dent for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff' 711113) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 F-1,60fl s.f. $272.00 Re -roof IREROOFRES Suppl. PC Fee: (E)Reg. OOT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee -0 Reg. Q OT0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Const-uction Tax:T_T_ -ldministr-ative Fee: Work Without Permit? © Yes (j) No $0.00 Advanced Planning Fee: $0.00 Select a Non -Residential Building or Structure i 7'rovel Documentation Fees: Strong- Motion Fee: 1BSEISMICR $0.62 Select an Administrative Item Bldg Stds Commission Fee: 1BCBSC $1.00 SUBTOTALS: $1.62 $272.00 TOTAL FEE: $273.62 Revised: 07/02/2015 r CUPERTINO REROOF TEAR -OFF POLICY COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 (408) 777-3228 - FAX (408) 777-3333 - buildino aQcuper ino.org PROJECT ADDRESS / 075 �/v.✓,Or�/rte. �+'�v� APN 4 OWNER NAME �.� P ONE G� $ib % Gr�a6 STREEeddDRESS CITY A 0 FAX `�r CONTRA/Cu1&NAME;0 A-� LICENSE NUM LICENSE TYPE BUS. LIC. d COMPA ME /� �� '✓ /� - � E-MAIL //++ r/�i•G2" t?r S�v� le�w-1 FAX S/o Z �fl-o 33 a STREET ADDRESS CITY, STATE, ZIP Ca- F 7__ PHONE Jeoe - 7 -rJ L iw sa- .-// I UNDERSTAND AND AGREE TO THE FOLLOWING: 1. The re -roof project shall comply with all applicable provisions of the 2013 California Codes. 2. An inspection request can be scheduled un to one business day before the requested inspection date. Please schedule inspections online or call (408) 777-3228 from 7:30-3:30pm (Mon-Thurs) or 7:30- 2:30pm (Friday) to schedule inspection. For Tear -Off and Nailing Inspections, you must also call on the day of the inspection only after that phase of the work is completed. The building inspector will be available within one hour. The hours for this service are: 7:30-10:30am and 12:30-3:30 (Mon-Thurs) and 7:30-10:30am and 12:30-2:30 (Friday). Final Inspections will be given a two hour window. 3. Tear -Off Inspection is required. Any and all dry -rotted wood shall be replaced prior to this inspection. Unless new plywood roof sheathing is proposed throughout, all the nails/fasteners shall be either completely knocked -down or removed prior to this inspection. 4. If plywood is installed, a plywood Nailing Inspection is required. 5. Roofing shall not be applied without first obtaining all prior inspection and written approvals from the building inspector. Any roofing which is applied without first obtaining an approved inspection will require the removal of all new material down to the sheathing so a proper inspection can be performed. 6. A Final Inspection and approval shall be obtained from the building inspector when the re -roofing is completed. To receive a final sign -off, the following items will be verified: a. Flat roofs shall have a minimum of I/4" per foot of slope and demonstrate there is no ponding. b. Listings from approved testing agencies for all pre -manufactured products used shall be available on-site to review at the time of the inspection. Proper spark arrestor installation, vents painted, gutter/downspouts installed, debris removed. 7. NOTE: If you call for a tear -off or plywood nailing inspection and the work is not complete, you will be charged a re -inspection fee. The re -inspection fee shall be paid before another inspection can be scheduled. . By my signing below, I certify each of the following is true: I am the property owner or authorized agent to act on the property owner's behalf. I understand and agree to comply with the re -roof policy stated above. I also understand that smoke detectors and carbon monoxide detectors are re ui_red to be installed in accordance with Sections R314 and R315 of the 2013 California Residential Code. Signature of Applicant/Agent: -- Date: ReroofPolicy_2014.doc revised 01/15/1=1 rpt_ R CUPERTINO Address \ ttk SMOKE I CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMIMUNITY DEVELOPMENT DEPART MENT - BUILDING DIVISION 10300 TORRE AVENUE - CUPER 7NO, CA 95014-3255 (408) 777-3225 - FAX (40B) 777-3333 - buiidinp�a /S'O PURPOSE TI -as affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11,2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwelluxigs, shall be provided with Smoke Alarms and Carbon 0 1 Monoxide alarms. M -ten the valuation of additions, alterations, or re -pairs to existing dwelling units exceeds $1000.00, CRC Section I2314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon. -Monoxide Alarms be installed in the following locations: r AREA SMOKE ALARM CO ALAR -31\1 C4 Outside of each separate sleeping area in the iini,_n eddate VjX d of the I bedroom(s) X X On eveLy.level of a dwellirtg unit including basements X X Within each slee-ping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. ro-v,7er Supply: In dwelling units with no com-mercial power supply, alarm(s) may be solely battery operated. where rep airs or alterations do In existing dwelling units, alarms are permitted to be solely battery operated wl not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section 8314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the g building wiring. 11") 1 As owner of the above -referenced property, I hereby certify that the alarrn's) referenced above hasrhave been installed in accordance with the _.nanuracturer'si.1l.structions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below. zz— I have read and agree to coir alyvvfth the terms and conditions of ,h;s sfatement Owner �AgiWt' Name: e(-,, vip, c �--Q *C)V�L ......... __ ........... ......... Date: 1b.5.bi Contractor Name: JCSV.I- 04_� c ............... Smo,',-e and COform,doc revised 03118114 42CSIMC4 V I a LfWAU=$ 101 I COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 1 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 CUPERTINO 1 (408) 777-3228 - FAX (409) 777-3333 - buildinca-cupertino.org Owner Name I Cx-^ Gr e- C � A 9L, Permit No. /6-0 Y" 16 Address (ADr ----- ----- PERN11T CANNOTBE FI-NALED AND COMPLETED UNTIL THIS 01HU'IFICATE IlIks 11t 1 N 5t 1) RF -T1,7 jLN_TjED TO THE BUILDING DINTISIO - . . .. . . . .. . . . Please refer to the attached California Civil Code Sections 1101.1 - 1101.8 which are part of this Certification form. 1. Is your real property a registered historical site? 0 Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: XNo Go to Question 2. Date: (-,) I \ C) )I I -!; 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water-conseiving plim-nbing fixtures is not technically feasible? 0 Yes Civil Code Sections 1101.1 through 1101.8 do not apply. D The licensed plumber's certification has been provided to the Building Division. Sign below and skip the rest of the form. Owner' Signature: No Go to Question 3. Date: tji15,e 7Y 3. Is ,,nater service permanently disconnected for your building? El Yes Civil Code Sections 1.1.01.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: No Go to Question 4. Date: 4. Is your real property built and available for use or occupancy on or before January 1, 1994? 0 No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: Date: Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Refer to the attached. My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvement--, shall require all non-compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non-compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). El My propert-y- is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or itnprovements shall require non- compliant plumbingfixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). 0 My property is a commercial real property. See Civil Code Section 11.01.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing -fixtures. SB407 2015.doc revised 0210485 On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I/We, the owner(s) of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California. Green Building Standards Code, and manufacturer's installation _requirements, and that the water conserving plumbing fixtures comply with the requirements as indicated in the table below. Owners (or OvCntr A e 's) Signature: ` Date: \ Upon completing and signing this Certificate, please return it to the Building Division in order to final your permit. 1. If the existing plumbing fixture water usager'flaw rate is equal to or lower than the figure shown, it is not required to be upgraded. 513407 2015. doc revised 02104/15 Non -Compliant Water -Conserving Plumbing Fixture i Plumbing Fixture (Fixture Complying with Current Code Applicable to New Construction) Maximum Water Usage/Flow Rate Fixture Type Water Usage 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 /Flow Rate Single -Family Multi -Family Commercial i Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 0.5 gallonstflush Gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets — Exceed 2.2 gallons Maximum 1.5 gallons per 1 Within units: 0.5 gallons per minute a 60 Lavatory per minute minute @ 60 psi; minimum ` Maximum 1.5 gallons psi j Faucets 0.8 gallons per minute @ per minute @ 60 psi; i 20 psi minimum 0.8 gallons I per minute @ 20 psi In common and public use areas. 0.5 gallons per minute @ 60 psi 1.8 gallons per minute ! 60 psi Faucets — Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum I 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction, other means may be used to achieve reduction. 1. If the existing plumbing fixture water usager'flaw rate is equal to or lower than the figure shown, it is not required to be upgraded. 513407 2015. doc revised 02104/15