13050021
• 'CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10699 LARRY WAY CONTRACTOR:SOLARCITY PERMIT NO:13050021 OWNER'S NAME: RAJPALI SAVITA ET AL 3055 CLEARVIEW WAY DATE ISSUED:05/03/2013 OWNER'S PHONE: 4082429676 SAN MATEO,CA 94402 PHONE NO:(650)638-1028 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL COMMERCIALS License Class C 4'� Lica# -6 6 5 (PI INSTALL 20 ROOF TOP FLUSH MOUNTED SOLAR PANELS Contractor Sa"r'C;4/ Date 51 3/ I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and thatmy license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of.consent to self-insure for Worker's Compensation,as providedfor by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$20000 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:31602008.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WIT I h 181 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for'inspection purposes. (We)agree to save 180 DA �S 'OM LAST CALLED INSP TON. indemnify and keep harmless the City of Cupertino against liabilities,judgments, / /� costs,and. expenses which may accrue against said City in consequence of the Issued by: Date: granting of this permit: Additionally,the applicant understands and will comply / with all non-point sou regulations per the Cupertino Municipal Code,Section 9.18. RE-ROOFS: Signatur " 3//3 Date ' All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materialsfor inspection. OWNER-BUILDER DECLARATION Signature of Applicant: Date:. • I.hereby affirm:that I am"exempt from the Contractorys License Law for one of the following two reasons:' ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the,proPerty,or my employees with wages as their sole compensation, will do the work,'and the'structure isnot intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec;7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: 1 ,1 i ' Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as.provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 2550 5533,and 25534. Section 3700'of the Labor Code,for the performance of the work for which this Date: /3�I 3 Owner or authorized agen . permit is issued. I certify that in the performance of the work for which this permit is issued,I shall not employ any person int,any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If,after making this certificate of exemption,I become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name • APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and;state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection.purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,;the applicant understands and will comply with all non-point source regulations,per the Cupertino Municipal Code,Section Licensed Professional 918. LII! ! I .1 I i I.' I Signature Date 1' ! 11 !111 '.1, 1 11,1 1 ' II 1 \\\t. // ALTERNATIVE ENERGY PERMIT APPLICATION V . COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION V ...,„.,9„ 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 A E (408)'777-3228 • FAX(408)777-3333 •buildinq@cupertino.orq ( CUPERTINO • PROJECT ADDRESS bu / AP"x 3 I (Q 0/7 0 �( p OWNER NAME •mf r`- * 1• 1 PH• I, I ` ..i: E- • 1 Gt/ refirllagi.11112a s a , , ' ) 0 6 -�- - -- . L 404- A , / STREET ADDRESS l Q/ q / 14 C7Q�A E `„.Lc 7 , v / 1 1 FAX CONTACT NAME A__,07--,,v1 ` �e/a _„/•L PHO I E-MAIL w ����„JJJJ ((( V� (.� STREET ADDRESS / CITY,STATE. ZIP FAX ❑ OWNER 0 OWNER-BUILDER 0 OWNER AGENT• lr,COINTRACTOR 0 CONTRACTOR AGENT 0 ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME4)) •l h l/i(��j�'I LICENSE NUMBER , / LICENSE TYPED't /� I BUS.Ll � � ae 14 Uset COMPANY NAME ,c.'`30 I, ^c1 i/ Ea \� WIl I��� ��6)A�t.l i /{4�-�/�lQ STREET ADDRES /.� s !t../M l ii Vol c CI YCCCJ!! (J-1 C _/ ( (/4 L� v` D/ 1.!! )_ J 3 77' ARCHITECT/ENGINEER NAME LICENSE NUMBER / BUS.LIC k COMPANY NAME ' E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF XSFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE. 0 Commercial URBAN INTERFACE AREA ❑ Yes ❑ No FLOOD ZONE ❑ Yes El NO I LAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING I ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS. KILOWATTS : v a k� TOTAL VALUATI$2O n / J v vim' e� DESCRIPTION OF WORK .- A — � 7 y j:li U✓44— l�� �/ 5dl ids ( `�, 91� RECE- D: ` . / By my signature below,I certify to each of the foils ing: I am the 1 operty o •r or authorized ages -o act on the p •pei owner's behalf. I have read this application and the information I have pr. ided I •rrect. I have re. the Descr•tion of Work a, d v: Ify it is accurate. ree to comply with all applicable local ordinances and state laws relating to bu %,in_c..: ction. I authori, represe 11.tive of pertmo • -nter the above-id• if ed property for inspection purposes. Signature of Applicant/Agent: A 6 / —1.4 '49 ' ` Date: 3 S ,LEMENTAL INFO' 'T ION REQUIRED - ..... , MICE USEUlla - . Os?ER=THE-COUN£ER - 'D' EXPRESSI .- ❑ STANDARD ci _z ❑ .. 4 . LARGE ,. a ❑ MAJOR PVApp_2011.doc revised 03/16/11 CITY OF CUPERTINO y` (t,,,,,// FEE ESTIMATOR—BUILDING DIVISION ADDRESS: DATE: 05/03/2013 REVIEWED BY: Mendez ".)' '' r 1' APN. BP#: *VALUATION: $20,000 a *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration/ Repair PRIMARY PENTAMATION SOLAR-RES USE: SFD or.Duplex PERMIT TYPE: i WORK install 20 roof top fl th mounted solar panels, 4.9 kw SCOPE OS 4 d q Mech. Plan Check Plumb Plan Check Elec.Plan Check I I Ltech.Permit Fee: Plumb. Permit Fee: Elec.. Permit Fee Other:ilech.Insp. Other Plumb Insp. Other Eke.Insp. Mech.Insp.lee: Plumb. Insp.Fee: Elee.Insp.Fee: NOTE:This estimate does not include fees due to other Departments(Le.Planning,Public Works,Fire,Sanitary Sewer District,School District,eta). These fees are based on the preliminary information available and are only an estimate. Contact the Dept for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff.' 7/1/12) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 I 1 I # Alternative Energy System Suppl.PC Fee: Q Reg. 0 OT 10.0 hrs $0.00 $219.00 IPHOTOVRES Photovoltaic System i PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp.Feer Reg. 0 OT 10.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Construction Tax: 11 Administrative Fee: Work Without Permit? 0 Yes C) No $0.00 tO Advanced Planning Fee: $0.00 Select a Non-Residential C Building or Structure (ravel Documentation Fees: A Strong Motion Fee: 1BSEISMICR $2.00 Select an Administrative Item Bldg Stds Commission Fee: 1BCBSC $1.00 ;-1 ; a a $3.00 $219.00 z.,Al.,,,, '>CO ‘',..4,-.0,a $222.00 Revised: 04/29/2013 / - Building Department City Of Cupertino 1,010300 Torre Avenue ss.I94 ,• Cupertino, CA 95014-3255 CUPERTINO Telephone: 408-777-3228 Fax: 408-777-3333 CONTRACTOR/ SUBCONTRACTOR LIST,: JOB ADDRESS: l / G l r PERMIT.# � (� ' OWNER'S NAME: /D / PHONE# yosn-s-tx. Z—(6 GENERAL CONTRACTOR: v n BUSINESS LICENSE .Z 3 ADDRESS: q 1 54.e/ii, teed. CITY/ZIPCODE: ,.-�' ( V 0 *Our municipal code requires all businesse working in the city to have-a City.of Cupertino business/license. NO BUILDING FINAL OR FINAL OCCUPANCY INS'ECTION S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL UBC,1 NTRAC t RS '' • OBTAINE' A'CITY OF CUPERTINO I BUSINESS LICENSE. ' / I am not using any subcontractors: , - •,/ 513/(3 Sign: re Date Please check applicable subcontractors and complete the following information: V SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE# Cabinets &Millwork Cement Finishing -::, : -, ,, - Electrical Excavation Fencing Flooring/Carpeting Linoleum/Wood Glass/Glazing Heating Insulation Landscaping Lathing Masonry Painting/Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile 46t4Cs'it .'c- i 13 13 Owner f ontractor Signature Date a ABBREVIATIONS ELECTRICAL NOTES INDEX LICENSE JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING PV1 COVER SHEET CA # 888104 FLASHING WILL BE PAINTED TO MATCH AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN PV2 SITE PLAN C-46, C-10 EXTERIOR POSITION, A SIGN WILL BE PROVIDED WARNING PV3 STRUCTURAL VIEWS BLDG BUILDING OF THE HAZARDS PER ART. 690.17. PV4 STRUCTURAL VIEWS CONC CONCRETE 2. EACH UNGROUNDED CONDUCTOR OF THE PV5 UPLIFT CALCULATIONS C COMBINER BOX MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PV6 THREE LINE DIAGRAM DC DIRECT CURRENT D DISTRIBUTIONPANEL BY PHASE AND SYSTEM PER ART. 210.5. PV7 ELECTRICAL CALCULATIONS EGC EQUIPMENT GROUNDING CONDUCTOR 3. A NATIONALLY-RECOGNIZED TESTING Cutsheets Attached - INSTALLING 18 ROOF-TOP, (E) EXISTING LABORATORY SHALL LIST ALL EQUIPMENT IN FLUSH-MOUNTED SOLAR PANELS EMT ELECTRICAL METALLIC TUBING COMPLIANCE WITH ART. 110.3. G SOLAR GUARD METER 4. CIRCUITS OVER 250V TO GROUND SHALL (4.41 KW) GALV GALVANIZED COMPLY WITH ART. 250.97, 250.92(B) SUPPLY SIDE TAP GEC GROUNDING ELECTRODE CONDUCTOR 5. DC CONDUCTORS EITHER DO NOT ENTER "SENT DEPARTMENT GND GROUND BUILDING OR ARE RUN IN METALLIC RACEWAYS GENERAL NOTES COMMUNITY HDG HOT DIPPED GALVANIZED OR ENCLOSURES TO THE FIRST ACCESSIBLE DC APPROVED ttRi I CURRENT DISCONNECTING MEANS PER ART. 690.31(E). ImpCURRENT AT MAX POWER 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN 1. THIS SYSTEM IS GRID-INTERTIED VIA A planskept This set of and specifications MUST be at the INVS INVERTERS RELIEF AT ALL ENTRY INTO BOXES AS UL-LISTED POWER-CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. job sit-,:during construction. It is unlawful to make any Isc SHORT CIRCUIT CURRENTcha„ges or alterations on same,or to deviate kVA KILOVOLT AMPERE 7. MODULE FRAMES SHALL BE GROUNDED AT THE 3. PHOTOVOLTAIC SOURCE AND INPUT CIRCUITS AND thcrafrom,without approval from the Building Official. kW KILOWATT UL-LISTED LOCATION PROVIDED BY THE INVERTER INPUT CIRCUIT ARE UNGROUNDED. LBW LOAD BEARING WALL MANUFACTURER USING UL LISTED GROUNDING 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED Thr aping of this plan and specifications SHALL NOT '"''" CUPERTINO MIN MINIMUM HARDWARE. 5. ALL WORK TO BE DONE TO 2010 CALIFORNIA b.REQUIRED BY UL LISTING. h,-,Id lc permit or to be an approval of the violation i '� ''', BIa;Id;n9 Dapartment MIR MIRROR 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, BUILDING CODE. e an proN,iolonsj of any City Ordinance or State Law. 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE `1, - (N) NEW RAIL, BOXES, ETC.) SHALL BE GROUNDED USING 2008 NATIONAL ELECTRIC CODE AS AMENDED BY "' LF '''' '1. " MAY 0 e 2013 NEC NATIONAL ELECTRIC CODE UL LISTED LAY-IN LUGS LISTED FOR THE THE 2010NACALIFORNIA ELECTRIC CODE. "S13 l (�' NIC NOT TOICONTRACT PURPOSE. POSTS CONTINUOUSHALL BE MADE (395COZ-_____..,, REVIEWED FOR CODE COMPLIANCE NTS NOT SCALE ELECTRICALLY WITH ATTACHED OC ON CENTER RAIL. Reviewed By ,,544,, /-irb / ` P PANEL BOARD 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE PL PROPERTY LINES BONDED WITH EQUIPMENT GROUND CONDUCTORS PV PHOTOVOLTAIC AND GROUNDED AT THE MAIN ELECTRIC PANEL. PVC POLYVINYL CHLORIDE 10. THE DC GROUNDING ELECTRODE CONDUCTOR P S SUBPANEL SHALL BE SIZED ACCORDING TO ART. VICINITY MAP catea SCH SCHEDULE 250.166(B) & 690.47. ;�- - „'Wr0,; �" ; .,. 8t SS STAINLESS STEEL t► I c --- , •: S 3 I SSD SEE STRUCTURAL DRAWINGS la litit-..-T la.y ---.."----.111111111111111& - 4R STC STANDARD TESTING CONDITIONS " !�` .amuf„,......,'"' . '. ... r a� ..,- 4 .I. ~ .• y�,_ �. ---.-..,,�!_'_SWH SOLAR WATER HEATER - - .� D.,„ TYP TYPICAL ' � 2${� ,Kin{ ero Serra"F _ _. 1► ':_� UON UNLESS OTHERWISE NOTED - R_--.i ; . i•� �.,` `} UPS UNINTERRUPTIBLE POWER SUPPLY eAVe ; �- .- _'-, LuciilenAve �. . V VOLT ,.,� �� ra+ = s Vmp VOLTAGE AT MAX POWER '# rP'•°- frit , _ _""�_ _``, Voc VOLTAGE AT OPEN CIRCUIT _ �i�".' , ' It - •. QlIVeWflod'St W WATT • CO • . f.� 3R NEMA 3R, RAINTIGHT i"" . ''�' Q."..,, -2,.• ,,� 1„ „, �£,�; L;- .,' ; ! • I ',13'.: enlnsula #,. ;�, �: �A� Beekman*PSTN BY DATE COMENTS p ' ' . . .,Bible Church - s l -71 1. .10. 'i f ..• , '� 5.1.'<i u ctr/Ih ' COM NTS' +C'�'', 1 rgr ,I.'-,..„.K.-, p _ _.IJ.$. - :,4 . ” I SurVQY." 1 al yy` '+ CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J B-9501640 00 PREMISE OMMER AHJ: DESCRIPTION: DESIGN: `����4 CONTAINED SHALL NOT BE USED FOR THE PAL, SANJAY PAL RESIDENCE Tyler Blauvelt :� �, BENEFIT SH LL IT ANYONE DI EXCEPT SOL WHOLE IRC I, MARKET: MO20S: 4.9 KW PV Array 'I' SoiarEity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI (20) TRINA SOLAR # TSM-245PC05/PA05.1810699 LARRY WAY PART TOZ OTHERS OUTSIDE THE RECIPIENTS AT PROJECT MANAGER: MOUNTING SYSTEM: C U P E R TI N O CA 95014 ��. 0� � ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTM CompMount Type C 3055 Cleorview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: Son Mateo, CA 94402 PERMISSION OF SOLARCITY INC. PAYMENT TYPE: INVERTER: 4082429676 4/30/2013 T:(650)638-1028 F:(>50) 638-102 PPA POWER-ONE # AURORA PVI-5000-OUTD-L,S-Z COVER SHEET PV 1 (888)-sa-aTY(7ss-248s www.soIarclt.com "' ,4...' PITCH: 23 ARRAY PITCH:23 :1-6.-1. _1_1 MP1 AZIMUTH: 179 ARRAY AZIMUTH: 179 .+ ""____ '''J Ii MATERIAL: Comp Shingle STORY: One Story At I•. Alai .V 0 le 1 ,:' x. �� 6 I 0 111%0 rf.- Ef \ <4r To ,•�� ,,'' W CUPERTINO i .o '..,t V 7'toPL 'r �� �i Building Department I f AC AC M , ,/, i'w,a r ...'1 r g ., ' ® HH o - \ ,. -'' , ., Jur '� �;;, _ �' ���� ,; ,L6 t MAY 0 2013 i °- ' �r1 / `r'EWED FOR CO(3E COMPLIANCE ,�: w s.: 4,1, eye/ evie'rved By ��,� t7� vim„. :1 r",, �`% testi r *S .:y • / ,!./AT, `iuy?>' / 10699 Larry Way / r I LEGEND 3°°81e�, 1 Ima-e r- a y[1- 1� , al I - - 35'to PL 0 O 0:::1 0 (E) UTILITY METER & WARNING LABEL �I ® INVERTER W/ INTEGRATED DC DISCO I & WARNING LABELS ( 35'to PL II II F DC DISCONNECT & WARNING LABELS Front Of House N ADD SISTERS �i AC DISCONNECT & WARNING LABELS III HERE 0 JUNCTION BOX Dill [E ® ® C H PV4 ® DC COMBINER BOX & WARNING / 0 DISTRIBUTION PANEL & WARNING \\ Lc LOAD CENTER & WARNING LABELS _ MP1 O B DEDICATED PV SYSTEM METER 1 PV3 "® CONDUIT RUN ON EXTERIOR 410 -•-- CONDUIT RUN ON INTERIOR 0 GATE/FENCE A --- INTERIOR EQUIPMENT 7 to PL 1 PV3 oR TOTAL ARRAY AREA = 326.14 SQ FT off, TOTAL ROOF AREA = 2368.8 SQ FT SITE PLAN N D % AREA = 13.8 % GT PV4 Scale: 1/8" = 1' W -� E Ni 0 1' 8' 16' CONFIDENTIAL- THE INFORMATION HEREIN £6 NUMBER: J 3-9501640 00 PREMISE OWNER AHJ. DESCRIPTION: DESIGN: `,0644 CONTAINED SHALL NOT BE USED FOR THE PAL, SANJAY PAL RESIDENCE Tyler Blauvelt :� %, BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES NOR SHALL IT BE DISCLOSED IN WH 'I/ SolarCityOLE OR IN REST (20) TRINA SOLAR # TSM-245PC05/PA05.18 10699 LARRY WAY 4.9 KW PV Array �,�j PART IZ OTHERS E OUTSIDE THE RECIPIENTS PROJECT MANAGER: MOUNTING SYSTEM: C U P E R TI N O, CA 95014 i%,; C r 3055 Clearview Way ORGANIZATION, EXCEPT IN CONNECTION WITH San 5MCle CA 94402 THE SALE AND USE OF THE RESPECTIVE Comp Mount Type C SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: INVERTER: PAGE NAME: SHEET: REV: DATE: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. PPA POWER-ONE # AURORA PVI-5000-OUTD-US-Z 4082429676 SITE PLAN PV 2 4/30/2013 (888)-SOL-CITY(765-2489)www.solarcity.com / 4' J' (E) 2x4 RAFTER ® 24" O.C. i i i i MODULES 6" \ T V OFF ROOF [ i A N ? (E) 2x4 il (11? „....r(0/ I 1 / 2'i00 \ (E) 2x4 RAFTERS CO 24'' SPACING 6'-10" / 4'-7"-------de (E) 2x6 CEILING JOIST ® 16" O.C. 1'_2''+ (E) LBW + (E) LBW FRONT VIEW OF MP1 SIDE VIEW OF MP1 RAFTER: 2x4 SCALE: 1/2" = 1' ANOTA R�UPGRADES NOT SHOWSUPPORT: 2x4, 2x6 SCALE: 1/4 -- 1 MAX SPAN: 6'-10" PV MODULE 5/16" BOLT WITH LOCK / INSTALLATION ORDER :1UPT(!NO • & FENDER WASHERS LOCATE RAFTER, MARK HOLE ,-Iriir Building Department ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. 02013 (4) (2) P OLSEYU PILOT HOLESWITH I REVIEWED FOR CODE COMPLIANCE ZEP COMP MOUNT C POLYURETHANE SEALANT. J ��) riwA1i N i'•, y ,.� /- _��-- �,. Reviewed B � �s� ZEP FLASHING C <� T�� �ag. (3) INSERT FLASHING. (E) COMP. SHINGLE vim; lmi - Co PLACE MOUNT. (E) ROOF DECKING MihMil MEM INSTALL LAG BOLT WITH 5/16" DIA LAG BOLT (5) (,5) SEALING WASHER. WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES LEVELING FOOT WITH (2-1/2" EMBED, MIN) 6., BOLT & WASHERS. (E) RAFTER S 1 STANDOFF Scale: 1 1/2" = 1' CONFIDENTIAL— THE INFORMATION HEREIN I JOB NUMBER J BPREMISE OMMER: AHJ: DESCRIPTION: DESIGN: 0.4 CONTAINED SHALL NOT BE USED FOR THE -9501640 00 PAL, SANJAY PAL RESIDENCE Tyler Blauvelt ��� �� BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: 4,9 KW PV Array 'I, SO�a �ty. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN REST (20) TRINA SOLAR # TSM-245PC05/PA05.18 10699 LARRY WAY -� J PRGA TO TI N, IIN THE ECTION PROJECT MANAGER: MING SYSTEM: CUPERTINO, CA 95014 . 3055 Gearvle.Way _ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE Comp Mount Type Son Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV DALE PERMISSION OF SOLARGTY INC. PAYMENT TYPE: INVERTER: T:(650)638-1028 F:(650)636-1029 PPA POWER-ONE # AURORA PVI-5000-OUTD-US-Z 4082429676 STRUCTURAL VIEWS PV 3 4/30/2013 (888)—SOL—CITY(765-2489) solarcHy.co„ (N) SIMPSON A34 CLIP W/ / 4' i (8) 8d (0.131x1.5") NAILS (E) 2x4 RAFTER • © 24" O.C. 8'-10" (+/-) • (E) 1x6 RIDGE BOARD 1 i �. i V i \ } 8'-9" /� k N N (E) 2x4 1j�jX i (E) 2x6 GUPERTINO (N) 2x4 DF #2 SISTER V4 / ^ '1 SEE TOP VIEW ♦ 2' (E) 2x4 SAE 13u1ld'ng Dzpartment ® 24" - 10'""' �r,,� , ^W, ‘ REVIEWED FOR CODE COMPLIANCE 0000001.11.1P- � (t) LBW } (E) 2x6 CEILING Reviewed By _54414 /7� df�3'-„"-� 8'-1” /-3'-6" JOIST @ 16" O.C. D FRONT VIEW OF MP2 SCALE: 1/2" = 1' 1,_24- (E) LBW _ , (E) LBW 0 SIDE VIEW OF MP2 RAFTER: 2x4 (N) SISTER MEMBER TO BEAR SUPPORT: 2x4, 1x6, 2x6 ON SUPPORT BELOW SIMPSON SDW 22458 SIMPSON SDW SCALE: 1/4" = 1' MAX SPAN: 8'-1" WOOD SCREWS 22300 WOOD (E) RAFTER SCREWS 111 iii . /////iiiiiii4/iiiii ii iii.iiiiii77////i ///// ///A r„„4,,,,,,„„,,„,iii iifi //7/ ilii /777,„iii1 M .I' 4'-0" MIN. (N) SIMPSON A34 CLIP J (E) WALL OR W/ (8) 8d (0.131x1.5") NAILS SUPPORT BELOW PV MODULE (E) RIDGE BOARD OR SUPPORT BELOW 5/16" BOLT WITH LOCK INSTALLATION ORDER TOP VIEW OF FULL LENGTH LAPPED SISTER • & FENDER WASHERS l LOCATE RAFTER, MARK HOLE NOTE: LAP SPLICE DOES NOT NEED TO BE CENTERED ON THE MEMBER Scale: 3/4"=1'-0" ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. SEAL PILOT HOLE WITH 6" END UPGRADE NOTES: (4) (2) DISTANCE POLYURETHANE SEALANT. f ,r 16" O.C., TYP.--1 ZEP COMP MOUNT C014— 4. NIMIMPINI i:; * 1. CUT AND ADD (N) SISTER AS SHOWN IN THIS :� 3 INSERT FLASHING. "' o — ° — ° c. — - SIDE VIEW AND REFERENCED TOP VIEW. ZEP FLASHING C `�� � � .: O 2. FASTEN (N) SISTER TO (E) MEMBER W/ / SIMPSON SDW (N) 2x4 SIDE MEMBER i r (E) COMP. SHINGLE �'; �� (� PLACE MOUNT. I WOOD SCREWS SIMPSON SDW 22300 (IF 2—PLY) OR 22458 (IF 3—PLY) SDW SCREWS STAGGERED AT 16" (E) ROOF DECKINGUMINSTALL LAG BOLT WITH O.C. ALONG SPAN AS SPECIFIED, IF WOOD 5/16" DIA LAG BOLT (5) (5) SEALING WASHER. 4110 2x4 END FASTENER GROUPING SPLITTING IS SEEN OR HEARD, PRE—DRILL LOWEST MODULE SUBSEQUENT MODULES WITH A DRILL BIT. WITH SEALING WASHER INSTALL LEVELING FOOT WITH Scale:l"=�'0" ALT. OPTION FOR FULL LENGTH MEMBERS (2-1/2" EMBED, MIN) (6) BOLT & WASHERS. ONLY— FASTEN (N) SIDE MEMBER TO (E) (E) RAFTER RAFTER W/ 10d (IF 2—PLY) OR 16d 0 STANDOFF FROM EACH SIDE (IF 3—PLY) COMMON Scale: 1 1/2" = 1' NAILS AT 6" O.C. ALONG SPAN. • SISTER ALL RAFTERS ON THIS MP SECTION INTO WHICH THE ARRAY IS LAGGED CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER JB-9501640 0 0 PREMISE OWNER. AHJ• DESCRIPTION: DESIGN 'O�r CONTAINED SHALL NOT BE USED FOR THE PAL, SANJAY PAL RESIDENCE Tyler Blauvelt �.I,•S��a�l BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: NNOR ORTSHHO ALL IT BERS WTSIOSED IN E RE PENTS OR IN RESI (20) TRINA SOLAR # TSM-245PC05/PA05.18 10699 LARRY WAY 4.9 KW PV Arra yOo ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: MOUNTING SYSTEM: CUPERTINO, CA 95014 ;;; ' ' C 3055 Cleariew Way THE SALE AND USE OF THE RESPECTIVE Comp Mount Type C San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTENPAGE NAME: SHEET: REV: DATE: PERMISSION OF SOLARCITY INC. PAYMENT TYPE: INVERTER: T:(650)638-1028 F:(650)638-1029 PPA POWER—ONE # AURORA PVI-5000—OUTD—US—Z 4082429676 STRUCTURAL VIEWS PV 4 . 4/30/2013 (86)-Sol-aTY(765-2489)www.solarcIty.com UPLIFT CALCULATIONS 04.29.2013 Version#9.4 SolarCity Wind Uplift Calculator Project Information Risk Category II PV System Type SolarCity SleekMount" Comp Roof Comp Roof #Layers(Comp Roof Only) 1 Roof Slope 23° Rafter Spadng 24"O.C. PV Module Orientation Landscape Total Area of Array 317 sf PV Module Width 3.3 ft PV Module Length 5.4 ft Attachment Type Comp Mount Type C Ground/Roof Snow Loads Ground Snow Load pg 0.0 psf ' ASCE Table 7-1 Roof Snow Over PV Modules ps-pv 0.0 psf Surrounding Roof Snow ps-roof 0.0 psf Wind Design Criteria Wind Design Code 0 ASCE 7-05 Wind Design Method 0 Partially/Fully Enclosed Method Basic Wind Speed V 85 mph Fig.6-1 Exposure Category 0 C ' Section 6.5.6.3 Roof Style 0 Gable Roof 'Fig.6-11B/GD-14A;'B Mean Roof Height 11 0 ft Section 6.2 Least Horiz.Dim. of Building [HD 0 ft i .t, � R (NO .. Effective Wind Area(I Module) A 17.6 sf IBC 1509.7.1 ,� Roof Wind Zone Width a 3 ft o Building Department Wind Pressure Calculation Coefficients 1 Wind Pressure Exposure Kz 0.85 Section 6-3 't_`` MAY 0 7113 Topographic Factor Kzt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Section 6-4 Importance Factor I 1.0 Table 6-1 REVIEWED FOR CODE COMPLIANCE Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 /_r 13.3 psf Reviewed By ___. -s,/ "7AT Wind Zone Interior(Zone 1) Edge(Zone 2) Corner(Zone 3) Ext. Pressure Coefficient(Up) GCp(Up) -0.9 -1.6 -2.5 Fig.6-118:C1D-14Al8 Ext.Pressure Coefficient(Down) GCp(Down) 0.5 0.5 0.5 Fig.6-118IC:0-14A/6 Design Wind Pressure p p= qh(GCp) Equation 6-22 Wind Pressure Up p(up) -11.7 psf -21.0 psf -32.7 psf Wind Pressure Down p(down) 10.0 psf 10.0 psf 10.0 psf Comp Allowable Attachment Spacing (In.)And Tributary Area (Ft^2) Interior(Zone 1) Edge(Zone 2) Corner(Zone 3) Max Allowed Foot X-Spacing Landscape 48" 48" 48" Max Allowed X Cantilever Landscape 24" 24" 24" Max Standoff Tributary Area TribCL 13 sf 13 sf 13 sf PV Assembly Dead Load WPV 3 psf 3 psf 3 psf DLPV PCL 39 lbs 39 lbs 39 lbs WLUP-0.6 DLPVcos(6) TCL -152 lbs -274 lbs -426 lbs Attachment Uplift Capacity Tallow 637 lbs 637 lbs 637 lbs TCL/Tallow DCRLand 23.9% 43.0% 66.9% CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J 3-9501640 00 PREMISE OWNER: AHJ: DESCRIPTION: DESIGN: viilkka4 CONTAINED SHALL NOT BE USED FOR THE PAL, SANJAY PAL RESIDENCE Tyler Blauvelt �� �, BENEFIT OF IT ANYONE EXCEPT SOL WHOLE INC., MARKET: MODULES:20 'It SoIarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI (20) TRINA SOLAR # TSM-245PC05/PA05.18 10699 LARRY WAY 4.9 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS PROJECT MANAGER: MOUNTING SYSTEM: CUPERTINO, CA 95014 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE CompMount Type C 3055 Cleaiew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. PAYMENT TYPE: INVERTER: 4082429676 4/30/2013 T:(650) 638-1028 F:(650) 638-1029 PPA POWER-ONE # AURORA PVI-5000-OUTD-US-Z UPLIFT CALCULATIONS PV 5 (888)-SOL-CITY(765-2489) www.sd°rcity.c°m GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) UFER AT PANEL (E) 125A MAIN SERVICE PANEL Inv 1: DC Ungrounded INV 1—(1)POWER-ONE#AURORA PVI-5000-OU1D-US-Z LABEL A —(20)TRINA SOLAR#TSM-245PC05/PA05.18 CA # 888104 WITH IRREVERSIBLE CRIMP E1002MAIN CIRCUIT BREAKER Tie-In: Supply Side Connection Inverter; 5000W, 240V, 96.5% PV Module 245W,222.9W PTC, 40MM, Black Frame Voc: 37.3 C-46, C-10 • Panel Number:TLM812F INV 2 Meter Number:1006503965 :30.7 Overhead Service Entrance INV 3 *MODULE CURRENT RATINGS ARE SHOWN AS Isc AND Imp IN THE DC STRINGS IDENTIFIER OF THE SINGLE LINE DIAGRAM. MAIN SERVICE PANEL CUTLER-HAMMER Inverter 1 IND Disconnect CUTLER-HAMMER 1 ® _ Disconnect 3Q POWER-ONE De+DO NOT ADJUST MIN.ACTIVATION V LTAGE i •�_ A 30A AURORA PVI-5000-OUTD-US-Z A DC- 1 Stnng(s)Of 8 On MP 2 • EGC J • • A \ = (\ �..\ LI 210V r 1� 100A/2P B A�\`•� 1 1 .-------•— , . L2N GFP/GFCI�� DC+ I �•-- _ EGC/ •/ DC+ I Y DC+DO NOT ADJUST MIN.ACTIVATION VOLTAGE (E) LOADS GND _Nisi - •� '1 � —- ----1�� GEC �_ DC_ L DC- 1 String(s)Of 12 On MP 1 �� ____J I GND I EGC I EGC J ITt/Lr (1)Conduit Kit; 3/e EMT N I 1 — I o z-z C., T GEC{ TO 120/240V SINGLE PHASE UTILITY SERVICE I II I , CUPERTINO 24 4- , Building Department ,t. 1! MAY 0 1 2013 REVIEWED FOR CODE COMPLIANCEI • Reviewed By' _;^4 /% POI T(2)I ns ti IPC eA �i Insulation Piercing Connector; Main 4/0-4,Tap 6-14 —(1) #�uabte IA311AC DC SSCSUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE —(2)F fPF 100A•Generd Duty(DO AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. —(1)ctlitgairlitate6°A a4.26°6 (2)FHRzRi sRGi r/1R3OR Pv RAcKREED OCP Fuee;30A.250V,noes RK5 BB I—t 1)WRfR-NeYER/Op2NRB (1)q t 30A,2D10Vae.bNarFuble,I e JR lkoviAlsubal AYIEN�IO&Cuwd Duty(DC) 4 (1)AWG#6, THWN-2,Black ( AWG#10,THWN-2, Black /� �\ (2)AWG#10,PV WIRE,Black Voc =298.4 VDC Isc =8.47 ADC O cm—(1)AWG#6, THWN-2,Red (. .5 1 g—(1)AWG#10,THWN-2, Red ( I 1 -4—(1)AWG#8.Solid Bare Copper EGC Vmp =245.6 VDC Imp=7.98 ADC (1)AWG#6, THWN-2,White NEUTRAL Vmp =240 VAC Imp=23 MC `J (1)AWG#10,THWN-2, White NEUTRAL Vmp =240 VAC Imp=23 MC �/ (1)Conduit Kit; 3/4' EMT —(1)AWG#6, Solid Bare Copper GEC —(1)Conduit Kit; 3/4'EMT —(1)AWG 18,THWN-2, Green EGC/GEC —(1)Conduit Kit; 3/4' EMT —(2)An#10,PV WIRE,Black Voc =447.6 VDC Isc =8.47 ADC O 0D (1)AWG#8,Solid Bare Copper EGC Vmp =368.4 VDC Imp=7.98 ADC (1)Conduit Kit; 3/e EMT CONFIDENTIAL- NE INFORMATION HEREIN JOB NUMBER J B—9 501 6 40 00 PREMISE OWNER AHJ: DESCRIPTION: DESIGN: 4!tAr CONTAINED SHALL NOT BE USED FOR NE PAL, SANJAY PAL RESIDENCE Tyler Blauvelt �; = BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: 4.9 KW PV ArraySoiarCi*Y NOR SHALL IT BE DISCLOSED IN WHOLE OR IN REST (20) TRINA SOLAR # TSM-245PC05/PA05.18 10699 LARRY WAY PART TO OTHERS THE RECIPIENT'S,ORGANIZATION, EXCEPT IN CONNECTION WIH PROJECT MANAGER: MOUNTING SYSTEM: CUP E R TI N O, CA 95014 -r/ie7 /^w7 3055 Clearview Way THE SALE AND USE OF NE RESPECTIVE Comp Mount Type C San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: OFAYMENT TYPE: INVERTER: PERMISSIONSOLARCITY INC. 4/30/2013 4082429676 PV 6 x'(650)638-1028 F:(650)638-1029 _ _ PPA POWER-ONE # AURORA PVI-5000-OUTD-US-Z THREE LINE DIAGRAM (888)-SOL-CITY '1. Conductor Sizing per Art 690.8(A) ELECTRICAL CALCULATIONS a. Conductor must have 30 deg. C ampacity >= 125% of continuous cd. current. Module: 20 TRINA SOLAR#TSM-245PC05 222.9 Inv Power WPTC Voltage Drop Calculations Version 5_8.0 Jake Tornatzky Inverter 1: 1 Power-One PVI-5000-S 0.965 5000 4301.97 Vdrop= Imp) * (2*Length)*(Resistance) / mp) b. Conductor must have (after corrections for conditions of use) >= Module: Imp(A) Max.Length(ft) Wire continuous current per Table 310.15(6)(16). Inverter 2: String: 7.98 70 AWG_10 at Max Ave Hi:80 deg F Module: Vdrop= (7.98 * 140 *0.00124011-ms) / 337.2096 0.62 Inverter 3: Branch: 7.98 I 0 AWG_10 I at Max Ave Hi:80 deg F c. Evaluate conductor temperature at terminations per 110.14(C). Vdrop= (7.98 *.0 *0.0 124Ohms) / 337.2096 0 Ampacity of wire derated for conditions of termination must be >= Module: Total voltage drop in DC conductors= 0.62 continuous current*1.25. All string terminations are rated at 90° C. Inverter 4: Inverter: 7.9820 I AWG_10 I at 240V * * Vdrop= (7.98 40 0.0012 Ohms) / 240 V 0.1596 Total: 20 Modules Total Inv Pwr: 5000 4301.97 PTC Combined: 0 I 0 I at 240V 2. OCP Sizing per Art 690.8(B)(1) Photovoltaic Module Electrical Specifications: Total STC: 4900 Vdrop= (0 *0 Ohms) / 240 V 0 a. Round up to next size per Art 240.4(B) Voc: 37.3 V deg F deg C 3. Conductor Sizing per Art 690.8(A) Vmp: 30.7 V Record Low Temp: 32 0 Total voltage drop in AC conductors= 0.16 Ise: 8.47 A Max Average Hi Temp: 80 27 Total voltage drop in AC and DC conductors= 0.78 a. Conductor must have 30 deg. C ampacity >= 125% of continuous Imp: 7.98 A Record Hi Temp: 87 31 current. Tvoc: -0.11532 V/deg C Tisc: 4.185 mA/deg C b. Conductor must have (after corrections for conditions of use) >= String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch Circuit Type A 1 way wire length: 0 continuous current per Table 310.15(B)(16). Voc Correction Factor: Power One PVI 5000 S 1 strings per branch 1 1 strings per branch 2 Inverter Min Vdc Input: 120 12 TRINA SOLAR#TSM-245PC05 12 modules per series string 8 modules per series string c. Evaluate conductor temperature at terminations per Art 110.14(C). Voc= 447.6 Min Vmp at Max Temp: 337.21 Voc= 447.6 V Voc= 298.4 V Ampacity of wire derated for conditions of termination must be >= Vmp= 368.4 Max Voc at Min Temp: 482.2 Vmp= 368.4 V Vmp= 245.6 V continuous current*1.25. All branch terminations are rated at 75' C Isc= 8.47 Inverter Max Vdc Input: 600 Isc= 8.47 A Isc= 8.47 A Max String Size: 14 min. Imp= 7.98 Imp= 7.98 A Imp= 7.98 A Icons= 10.59 Art 690.8(A)(1) 1-way wire length: 70 (cont= 10.59 A Icont= 10.59 A Art 690.8(A)(1) 4. OCP Sizing 1.a Conductor: AWG_10 I PV Wire 2.a Conductor 1: AWG_10 PV Wire a. Round up to next size per Art 240.4(B) Conductor 2: AWG_10 PV Wire (cont*1.25=(Amps) 13.23 Conductor 1 Conductor 2 5. Conductor Sizing per Art 690.8(A) 30 deg C ampacity= 40 (cont*1.25=(Amps) 13.23 13.23 a. Conductor must have 30 deg. C ampacity >= 125% of continuous 1.b Icont=(Amps) 10.59 30 deg C ampacity= 40 40 Start ampacity 40 2.b Icons=(Amps) 10.59 10.59 current. Temperature derate(%=F) 0.71 Start ampacity 40 40 Conduit fill derate(%=#) 1 Temperature derate(%=F) 0.82 0.82 b. Conductor must have (after corrections for conditions of use) >_ Derated ampacity 28.4 Conduit fill derate(%=#) 0.8 0.8 : ,LJPER"�"'NQ, continuous current per Table 310.15(6)(16). 1.c Derated ampacity 26.24 26.24 I r `,. •s Icont*1.25=(Amps) 13.23 2.c Term 1 Term 2 I(aM�j • �''-=Z �Il�itl� Department Ampacity 40 Temp table 75degC 75degC `+ c. Evaluate conductor temperature at terminations per Art 110.14(C). a+9 CQ hI Ampacity of wire derated for conditions of termination must be >= 1.d (cont*1.25=(Amps) I 13.23 I Icont*1.25=(Amps) 13.23 13.23 a l a 2 continuous current*1.25. All inverter output terminations are rated at OCP Size= 15 Ampacity 35 35 t _ r .`•! � - }t„t (,C�i?iw COMPLIANCE 75° C. Inverter Type A Output 2.d OCP Size= I 15 15 Power-One PVI-5000-S 1 way wire length: 10 ft Reviewed By .___24.7,4 /1/47-‘,./6. OCP Sizing � Combined Inverter Output • Icont= I 23 I A Art 690.8(A)(1) Service Voltage= a. Round up to next size per Art 240.4(B) 3.a Icont*1.25=(Amps) 28.75 Art 690.8(B)(1) Total Inverter Power= 1 way wire length= 0 OCP Size= 30 Art 240.6(A) (cont=#of inverters*max inverter current Art 690.8(A)(1) 7. Conductor Sizing per Art 690.8(A) 3.b Conductor: AWG_10 THN-2 at 90 deg C:Table 310.16 Icont=(Amps) W a. Conductor must have 30 deg. C ampacity >= 125% of continuous Icont*1.25=(Amps) 28.75 4.a Icont*1.25=(Amps) Art 690.8(6)(1) Current. 30 deg C ampacity= 40 OCP size= Art 240.6(A) 3.c Icont=(Amps) 23 4.b Conductor: 'THWN-2 at 90 deg C:Table 310.16 Icont*1.25=(Amps) b. Conductor must have (after corrections for conditions of use) >= Start ampacity 40 30 degC ampacity= Temperature derate(%=F) 0.91 p y continuous current per Table 310.15(6)(16). Conduit fill derate(%=#) 1 4.c Icons=(Amps) Derated ampacity 36.4 Start ampacity c. Evaluate conductor temperature at terminations per Art 110.14(C). 3.d Icont*1.25=(Amps) 28.75 Temperature derate(%=F) Ampacity of wire derated for conditions of termination must be >= Ampacity 35 Conduit fill derate(%=#) continuous current*1.25. All inverter output terminations are rated at Derated ampacity 4.d Icont*1.25=(Amps) 75' Cmin. I Ampacity CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER J B-9501640 00 PREMISE OWNER AHJ: DESCRIPTION: DESIGN: `Odd CONTAINED SHALL NOT BE USED FOR THE PAL, SANJAY PAL RESIDENCE Tyler Blauvelt .it BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES S ��a l NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 10699 LARRY WAY PART TO OTHERS OUTSIDE ME RECIPIENT'S REST (20) TRINA SOLAR # TSM-245PC05/PA05.18 4.9 KW PV Array ORGANIZATIONty, , EXCEPT IN CONNECTION MATH PROJECT MANAGER: MOUNTING SYSTEM: C U P E R TI N O, CA 95014 • 3055 Clearview way THE SALE AND USE OF THE RESPECTIVE Comp Mount Type C San Mateo, CA 94402 SOLARaTY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: INVERTER: PAGE NAME: SHEET: REV: DAZE: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARgTY INC. PPA POWER-ONE # AURORA PVI-5000-OUTD-US-Z 4082429676 ELECTRICAL CALCULATIONS PV 7 4/30/2013 (888)-SOL-aTY(765-2489)vwwsolarclty.com • CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE • FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: INVERTER & . ITC El UTILITY SER AC DISCONNECT VICE FRONT OF HOME \ El . SOLAR PHOTOVOLTAIC ON ROOF El PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS 11 CUP RTf NO Building Department A/C DISCONNECT PER NEC 690.17 i ;��—va ii riV: . 2013 OPERATING VOLTAGE = 240 V MAX CURRENT = 16 A :'i E V I El" -OR �, ._:..,1 ; (..,ODE COMPLIANCE R J I :VI IA�Gd By -,/EAN /L1/ CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER J B-9 501 6 40 0 0 PREMISE OWNER AHJ: DESCRIPTION: DESIGN: `bit44 CONTAINED SHALL NOT BE USED FOR THE PAL, SANJAY PAL RESIDENCE Tyler Blauvelt 1;1 BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,IMARKET: MODULES: I�i�SotarCity FARTST OTHERS DISCLOSED IN RECIPIENr31N REST (20) TRINA SOLAR # TSM-245PC05/PA05.18 10699 LARRY WAY 4.9 KW PV Array ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: MOUNTING SYSTEM: C U P E R TI N O, C A 95014 '%/� �Q % 3055 Clearview Way 'THE SALE AND USE OF THE RESPECTIVE Comp Mount Type C PAGE NAME SHEET: REV: DATE: San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: INVERTER: 1:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. PPA POWER—ONE # AURORA PVI-5000—OUTD—US—Z 4082429676 SITE PLAN PLACARD PV 8 4/30/2013 (888)-SOL-arr(ass-lass)►�. salaranya«n Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT (C) MAXIMUM AC _ A (AC) (POI) WARNING (DC) (INV) Per Code: OPERATING CURRENT Per Code: Per Code: CA Fire Guidelines MAXIMUM AC - v CEC 690.54 ELECTRIC SHOCK HAZARD CEC 690.35(F) OPERATING VOLTAGE THE DC CONDUCTORS OF THIS Label Location: PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN UNGROUNDED AND INVERTER IS PHOTOVOLTAIC DC (DC) (INV) MAY BE ENERGIZED UNGROUNDED DISCONNECT Per Code: CEC 690.14.C.2 Label Location: PV SYSTEM (AC) (P01) DISCONNECT FOR UTILITY OPERATION Label Location: MAXIMUM POWER-_A (DC) (INV) POINT CURRENT(Imp) Per Code: MAXIMUM POWER-_ CEC 690.53 POINT VOLTAGE(Vmp) MAXIMUM SYSTEM_V Label Location: VOLTAGE(Voc) WARNING (AC) (P01) SHORT-CIRCUIT CURRENT(Isc) A ELECTRIC SHOCK HAZARD Per Code: CEC 690.17 DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Location: WARNING (DC) (CB) Per Code: ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS CEC 690.17 Label Location: TERMINALS ON BOTH LINE AND PHOTOVOLTAIC POINT OF (P01) LOAD SIDES MAY BE ENERGIZED INTERCONNECTION Per Code: IN THE OPEN POSITION WARNING ELECTRIC SHOCK DC VOLTAGE IS HAZARD. DO NOT TOUCH CEC 690.54; CEC 690.17 ALWAYS PRESENT WHEN TERMINALS.TERMINALS ON SOLAR MODULES ARE BOTH THE LINE AND LOAD SIDE EXPOSED TO SUNLIGHT MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE MAXIMUM AC Label Location: OPERATING CURRENT WARNING (DC) (INV) MAXIMUM AC { ' CUPERTINO Per Code: OPERATING VOLTAGE V !IV-1 aullding DepartmentELECTRIC SHOCK HAZARD CEC 690.5(C) l ',; IF A GROUND FAULT IS INDICATED 1 :r 4 i A � i NORMALLY GROUNDED , / - ' i� n 2[ 3 CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Label Location: REVIEWED FOR CODE COMPLIANCE CAUTION (D) (POI) Reviewed By _5;67,/ //A7 Per Code: PHOTOVOLTAIC SYSTEM CEC 690.64.B.4 Label Location: CIRCUIT IS BACKFED PHOTOVOLTAIC AC (AC) (P01) (AC): Disconnect Per Code: (C)):: Conduit DISCONNECT (CB): Combiner Box CEC 690.14.C.2 (D): Distribution Panel Label Location: (DC): DC Disconnect CAUTION (P01) (IC): Interior Run Conduit DUAL POWER SOURCE Per Code: SECOND SOURCE IS CEC 690.64.8.4 (INV): Inverter With Integrated DC Disconnect PHOTOVOLTAIC SYSTEM (LC): Load Center (M): Utility Meter (P01): Point of Interconnection CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR %1I� .„..,,,,,,orj 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED As. San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, S C - CA Label Set j��� T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE ,/ So I a rC i t .. (888)SOL-CITY(765-2489)www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. • mono multi solutions TrinamOUllt II FOR PITCHED ROOF TSM-PC05/ PA05.18 mono multi solutions ELECTRICAL DATA STC TSM-225 TSM-230 TSM-235 TSM-240 TSM-245 DIMENSIONS OF PV MODULE TSM-PC05/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 Peak Power Watts-P.m 225 230 235 240 245 • 936 10 YEAR A R Power Output Tolerance-Pox,(%) 01+3 0/+3 0/+3 0/+3 0/+3 Ii na m o u n t 111111 m c - Maximum Power Vottoge Vim(V) 29.4 29.8 30.1 30.4 30.7 PRODUCT WARRANTY FOR MODULE Maximum Power Current-Iorr(Al 7.66 7.72 7.81 7.89 7.98 by Trmasolar AND MOUNTING SYSTEM Open Circuit Voltage-Voc(V) 36.9 37.0 37.1 37.2 37.3 FOR PITCHED ROOF Short Circuit Current-Isc,Al 8.20 8.26 8.31 8.37 8.47 5XModule Efficiency nn,(%) 13.7 14.1 14.4 14.7 15.0 FASTER TO INSTALL AL dA Values at Standard Test Conditions STC(Air Moss AM1.5.Irradiance 1000W/m'.Cell Temperature 25°C). ULTRA L O • ELECTRICAL DATA 00 NOCT TSM-225 TSM-230 TSM-235 TSM-240 TSM-245 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 RESISTANCE - Maximum Powe(W( 164 168 172 175 178 a xG Maximum Power Voltage(VI 26.9 27.1 27.4 27.7 27.8 8 e3 GROUND BOND CONNECTION "°- Maximum Power Current(A) 6.12 6.20 6.27 6.32 6.41 10X BETTER THAN UL MINIMUM CRITERIA GPOU=GOLE I Open Circuit Voltage IV) 33.8 33.9 34.0 34.1 34.2 -w,.. "x'" Hn Q Short Circuit Current(A) 6.62 6.68 6.70 6.75 6.83 • • NOCT:Irradiance al 800W/m'.Ambient Temperature 20°C,Wind Speed 1 M/s. 4 ; -F Back View a4 MECHANICAL DATA Solar cells Multicrystalline 156 x 156mm(6 inches) 11 I Cell orientation 60 cells(6 x 10) , ��,� " Module dimension 1650 x 992 x 40mm(64.95 0 39.05 x 1.57 inches) , 1 i �. Y\ "s.., I ,1_ ,,��'�,ty 4'� \\:,,t......-•-` k �->~~ Weight 20.3kg(44.8 Ib) 4 �`" �, Z a Glass High transparancy solar glass 3.2mm(0.13 inches) \\\si...'y\ \°\ 2.s.-c- ,, s- ��� Frame Anodized aluminium alloy - 1 -, _ J-Box IP 65 rated t 1,^'' A-A Cables/Connector Photovoltaic Technology cable 4.0mm'(0.006 inches'), 1100mm(43.3 inches),MC4/H4 I-V CURVES OF PV MODULE TSM-230PC05/PA05.18 9)0 i 1000W/m' , 89.r-'--- - TEMPERATURE RATINGS . 700 1'8DtfV77rr7- Nominal Operating Cell 46°C(+2°C) 69. 600 I --- --------y Temperature(NOCT) a 600W/m' i � Temperature Coefficient of P.m -0. _-.-_ •'S; C V P E RT I N O ,I 400w/rsit" -- --- - _-- - --- ' Temperature Coefficie D 3' zoow/mT---- ----- - TemperatureCoefficiienntatIre .04i ' ` j,^,)!I!!'�1)'1(� Dapartrttent 2� -----...----------------- \ --- �ti..,... SUITABLE FOR COMBINING PV MODULE EXPERTISE WITH A HIGHLY D� °' MAY L0 3 2011 0.`° 1000 2040 30!° 400° -�' =_ Voltage(V( INNOVATIVE MOUNTING SYSTEM SOLUTION. MAXIMUM RATINGS �` ■m■ COMPOSITION SHINGLE Operational Temperature -40-+85°C RE',,J)E6/Vrl,;: (-(1R CODE COMPLIANCE mg. Trina Solar is introducing Trinamount-the fastest,easiest and least Maximum System Voltage IOOOV DC(IEC)/600V expensive way to mount PV modules onto residential and commercial DC(UL) Reviewed'rVVlBBd BY a ® rooftops.With a series of drop-in and quarter-turn connections on a Max Series Fuse Rating 15A �"-" 6_ TRAPEZOIDAL METAL specialized module frame,this mounting solution installs up to 5 times CERTIFICATION k faster than conventional mounting systems.Trinamount connects directly to the module frame, eliminating the need for long rails. (E ISO PV CYCLE il COUS WARRANTY rt - V ;:,.„K usTED R STANDING SEAM ROOF By drastically reducing the number of parts,cost of materials and 10year workmanship warranty installation time,Trinamount offers the optimal solution for residential C ►�,, w� 25 year linear performance warranty �r and commercial installations. (Please refer to product warranty for details) Q�0MP4TS@ Trinasolar W Trmasolar 9 CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. The power behind the panel coMPpt, The power behind the panel @ 2011 Trina Solar Limited.All rights reserved.Specifications included in this dotosheet are subject to change without notice. • SolarCity SleekMountTM - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules aesthetics while minimizing roof disruption and • Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and • Interlock and grounding devices in system UL Fastener Size Per NDS Section 1.1.3.2 listed to UL 2703 mounting clamps, combined with the addition ® Seal pilot hole with roofing sealant of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 to a more visually appealing system.SleekMount as"Grounding and Bonding System" ® Insert Comp Mount flashing under upper utilizes Zep CompatibleTM modules with •Ground Zep UL and ETL listed to UL 467 as q layer of shingle strengthened frames that attach directly to grounding device Place Comp Mount centered Zep Solar standoffs, effectively eliminating the need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition 0 Install lag pursuant to NDS Section 11.1.3 •Anodized components for corrosion resistance shingles are not required to be cut for this with sealing washer. system, allowing for minimal roof disturbance. •Applicable for vent spanning functions 0 Secure Leveling Foot to the Comp Mount using machine Screw 0 Place module cti c1 A Components B �'���_ 5/16"Machine Screw •v. 0 Leveling Foot �• mit trili ,, 0 Lag Screw 11- ti 1 0 Comp Mount r Comp Mount Flashing ... 0 0© D 0• `; 0 `, E ® i�;01 =-r CUPERTINO op At ,• �I `` e' 1 ?u,,ilding Department . , ._..J MAY 02013 REVIEWED FOR CODE COMPLIANCE Reviewed By -, //4T SolarCity© January / 4, ETI LISTED SoiarCity® January Janua 2013 compos Janua 2013 POlief-0118® /\hL..JROR .`./Renewable Energy SolutionsTECHNICAL DATA VALUES PVI-5000-OUTD-US PVI-6000-OUTD-US Nominal Output Power W 5000 6000 Maximum Output Power W 5000 6000 O Rated Grid AC Voltage V 208 240 277 208 240 277 Z Input Side(DC) Number of Independent MPPT Channels 2 2 i PVI-5000-TL Q Maximum Usable Power for Each Channel W 4000 4000 cc Absolute Maximum Voltage(Vmax) V 600 600 C) Start-Up Voltage(Vstart) V 200 (ad).120-350) 200 (ad).120-350) PVI—6 00 0—T J Full Power MPPT Voltage Range V 200-530 200-530 r Q Operating MPPT Voltage Range V 0.7xVstart-580 0.7xVstart-580 Maximum Current(Idcmax)for both MPPT in Parallel A 36 36 Maximum Usable Current per Channel A 18 18 GENERAL SPECIFICATIONSMaximum Short Circuit Current Limit per Channel A 22 22 � Number of Wire Landing Terminals Per Channel 2 Pairs 2 Pairs I OUTDOOR MODELS CC Array Wiring Termination Terminal block,Pressure Clamp,AWG8-AWG4 ® • Output Side(AC) Grid Connection Type 10/2W Split-0/3W 10/2W 10/2W Split-0/3W 10/2W ix�r AdjustableVoltage Range(Vmin-Vmax) V 183-228 211-264 244-304 183-228 211-264 244-304 Grid Frequency Hz 60 60 Adjustable Grid Frequency Range Hz 57-60.5 57-60.5 <` Maximum Current pacmax) ARMS 27 23 20 30 28 24 Power Factor >0.995 >0.995 Total Harmonic Distortion At Rated Power % <2 <2 Designed for residential and small commercial PV installations,this Contributory Fault Current** Ae/Aare, 36.25/25.63 36.5/25.81 31.75/22.45 36.25/25.63 36.5/25.81 31.75/22.45 Grid Wiring Termination Type Terminal block,Pressure Clamp,AWG8-AWG4 inverter fills a specific niche in the Aurora product line to cater for Protection Devices those installations producing between 5kW and 20kW. Input fsG• Reverse Polarity Protection Yes Yes ,�ss �t� Over-Voltage Protection Type Varistor,2 for each channel Varistor,2 for each channel This inverter has all the usual Aurora benefits,including dual input �� , - PV Array Ground Fault Detection Pre start-up Riso and dynamic OFOl Pm start-up Riso and dynamic GFDI section to process two strings with independent MPPT,high speed Output (Requires Floating Arrays) (Requires Floating Arrays) and precise MPPT algorithm for real-time power tracking and Anti-Islanding Protection Meets UL 1741/IEE1547 requirements Meets UL 1741/IEE1547 requirements J - energy harvesting, as well as transformerless operation for high Over-Voltage Protection Type Varistor,2 IL,-L,/L,-G) Varistor,2(Li-1.2/L,-G) performance efficiencies of up to 97.1%. UNO Maximum AC OCPD Rating A 35 30 25 40 35 30 ) Efficiency Maximum Efficiency % 97.1 97.1 The wide input voltage range makes the inverter suitable to low a CECratng Efficiency % 96 96.5 96.5 96 96.5 96.5 _ ,. Operating Performance power installations with reduced string size.This outdoor inverter Stand-by Consumption Warns <8 <8 has been designed as a completely sealed unit to withstand the Night time consumption warts <06 <0.6 Communication harshest environmental conditions. - User-Interface 16 characters x 2 lines LCD display Remote Monitoring(1xR5485 incl.) AURORA-UNIVERSAL(opt) �'aa 1110 Wired Local Monitoring(1xRS485 incl.) PVI-USB-RS485_232(opt.),PVI-DESKTOPt)) J U P E RTI NO Wireless Local Monitoring PVI-DESKTOP(opt.)with PVI-RADIOMODUKpt.) w J J Environmental -13 toI�I lll(�It1Q Department • v Ambient Air Operating Temperature Range °F(°C) -13 to+140(-25 to+60) 3 40(-25 to+6b) with der t•r-above.122;(50) * Ambient Air Storage Temperature Range °F(°C) -40 to 176(-40 to+80) -40 t o•f i'(-40 to+80) t tsyq�} Relative Humidity %RH 0-100 condensing 0th atInflAPA.iogfikj Ij1oT Acoustic Noise Emission Level db(A)@1 m <50 <50 Maximum Operating Altitude without Derating ft(m) 6560(2000) -S60(2000)• ,-- Mechanical Specifications • .4-V `2 L., r;JR COUE COMPLIANCE Enclosure rating NEMA 4X NEMA 4X Cooling Natural Convection Natural Convk,ctio. ��',1 • Each inverter is set on specific grid codes which can be selected in the fieldiopi fy�tj By yJ Dimensions(H x W x D) in(mm) 41.4 x 12.8 x 8.6(1052x 325 x218) •Single phase output Weight lb(kg) <59.5(27.0) <59.5(27.0) • Dual input sections with independent MPPT,allows optimal energy harvesting from two sub-arrays oriented Shipping Weight lb(kg) <78(35.4) <78(35.4) Mounting System Wall bracket Wall bracket in different directions Trade Size Kos:(tea x 1/2") Trade Size Kos:(2ea x 1/2") Conduit Connections and(tea x 1-1/4, places laces side,front,rear) and(tea x 1-1/4, places laces side,front,rear) •Wide input range DC Switch Rating-(Per Contact) AN 25/600 25/600 • High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting Safety •Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance Isolation Level Transformerless(Floating Array) Transformerless(Floating Array) across the entire input voltage and output power range Safety and EMC Standard UL 1741,CSA-C22.2 N.107.1-01 UL 1741,CSA-C22.2 N.107.1-01 Safety Approval ,CSA.,, ,CSA,„ •Outdoor enclosure for unrestricted use under any environmental conditions Warranty • RS-485 communication interface(for connection to laptop or datalogger) Standard Warranty years 10 10 I Extended Warranty years 15&20 15&20 •Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP Available Models Standard-With DC Switch-Floating Array PVI-5000-OUTD-US PVI-6000-OUTD-US 'All data is subject to change without notice "Inverter can apply that much current-Breaker will open r , CSA Group Certificate of Compliance Certificate: 1841082 Master Contract: 173688 Project: 2550432 Date Issued: August 20,2012 Issued to: Power-One,Inc 740 Calle Plano Camarillo,CA 93012 USA Attention:Robert White The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C'and 'US'for Canada and US or with adjacent indicator 'US'for US only or without either indicator for Canada only. IP® Brij fl ewc . Issued by: Brij Aggarwal,P.Eng. C US PRODUCTS CLASS 531109 -POWER SUPPLIES-Distributed Generation Power Systems Equipment CLASS 531189 -POWER SUPPLIES-Distributed Generation-Power Systems Equipment -Certified to U.S.Standards Utility Interactive Inverter,Models PVI-6000-OUTD-US,PVI-6000-OUTD-US-W and PVI-5000-OUTD-US, permanently connected: Notes: ._ 1. All above models in this series may include expansion board with wireless antennae option and will be i n;R. 7:: { C U PERTI NQ identified with model designation including"Z"suffix at the end. ! 7+iil�l;np i�2partrrlent E'` 1 2. For details related to rating,size,configuration,etc.reference should be made to the CSA Certification Record,Annex A of the Certificate of Compliance,or the Descriptive Report. ',R, 2U13 FOR COOE COMPLIANCE DQD 507 Rev.2012-05-22 Page:1 a