BAKCFLOW CERTIFICATION OF RE-CLAIMED WATER SYSTEMS ,_-"" CROSS CONNECTION SPECIALISTS
CERTIFIED CROSS CONNECTION CONTROL CONSULTANTS BACKFLOW PREVENTION VALVE EXPERT
I NSTALLATION-REPAI RS-TESTING-CERTIFICATION
it • 'Stro4ClaN'9sa
BACKFLOW PREVENTION SPECIALISTS, INC,
LICENSED CONTRACTOR C.C.L.#427328 CALIFORNIA (800)464-FLOW(3589)
3750-E CHARTER PARK DR.,SAN JOSE CA 95136-1356 (408)269-2600
1522-A DAY AVE.,SAN MATEO CA 94403 FAX(408)269-2650
SERVICE ADDRESS 22622 Marianist Way.,Cuperiino/X-Vos&Foothill Blvd
MAILING ADDRESS The Marianist Center CONTACT SteVC
22622 Marianist Way TEL# 253-6979
Cupertino, CA 95014
MANUFACTURER MODEL NUMBER TYPE SIZE SERIAL NUMBER
FebDo 765 PVB 2" 80610
INTERNAL TAG LOCATION OF DEVICE irrigation
EXTERNAL Cl
IF DEVICE IS ANEW INSTALLATION PLEASE CHECK THIS BOX[:I PASSWFAIL❑
• REDUCED PRESSURE DEVICES
PRESSURE TYPE
DOUBLE CHECK VALVES VACUUM BREAKERS
RPP VALVES DIFFERENTIAL
CHECKVALVE CHECK VALVE PRESSURE/RELIEF
N0,1 N0.2
VALVE AIR INLET CHECK VALVE CLOSED TIGHT ❑ CLOSED TIGHT Cl //,,OPENED AT_LES. OPENED AT7 '�LBS CLOSED TIGHT
INITIAL #lbs. #lbs. #LBS #LBS. 7- Z
TEST OPENED UNDER 2.0 OPENED UNDER 1.0
LEAKED ❑ LEAKED ❑ OR DID NOT OPEN ❑ OR DID NOT OPEN ❑ LEAKED ❑
REPAIRS
AND
` MATERIALS
USED
FINAL CLOSED TIGHT Cl CLOSED TIGHT ❑ CLOSED TIGHT❑
TESTOPENED AT_LBS OPENED AT_LBS
#LBS #LBS #ls5
THE ABOVE REPORT IS CERTIFIED TO BE TRUE
INITIAL TEST BV CERTIFIED TESTER NO.Z� DATE 3-17-03
• REPAIRED BY
DATE MO. DAY YR.
FINAL TEST BY CERTIFIED TESTER NO. DATE
MO. DAY YR.
CERTIFICATION OF RE-CLAIMED WATER SYSTEMS �sA1". CROSS CONNECTION SPECIALISTS
CERTIFIED CROSS CONNECTION CONTROL CONSULTANTS BACKFLOW PREVENTION VALVE EXPERT
INSTALLATION-REPAIRS-TESTING-CERTIFICATION
BACKFLOW PREVENTION SPECIALISTS, INC,
LICENSED CONTRACTOR C.C.L.#427328 CALIFORNIA (800)464-FLOW(3569)
3750-E CHARTER PARK DR.,SAN JOSE CA 95136-1356 (408)269-2800
1522-A DAY AVE.,SAN MATEO CA 94403 FAX(408)269-2850
SERVICE ADDRESS 22622 Marianist Way.,Cupertino/X-Vos&Foothill Blvd
MAILING ADDRESS The Marianist Center CONTACT Steve
22622 Marianist Way TEL# 253-6979
Cupertino,CA 95014
MANUFACTURER MODEL NUMBER TYPE SIZE SERIAL NUMBER
Watts 009M1 RP 2" 91593
INTERNAL ❑ TAG LOCATION OF DEVICE next to fence by dining ball irrigation
EXTERNAL ❑
IF DEVICE IS ANEW INSTALLATION PLEASE CHECK THIS BOX[] PASA FAIL❑
• REDUCED PRESSURE DEVICES PRESSURE TYPE
DOUBLE CHECK VALVES VACUUM BREAKERS
RPP VALVES DIFFERENTIAL
CHECK VALVE CHECK VALVE PRESSURE/RELIEF
NO.1 N0.2
VALVE AIR INLET CHECK VALVE
CLOSEDTIGHT • LBS.CLOSEDTIGHTO_ OPENED ATZOPENEDAT_LBS CLOSED TIGHT ❑
INITIAL #Ibs.—fpL)r� #Ibs. ALBS #LBS,
TEST OPENED UNDER 2.0 OPENED UNDER 1.0
LEAKED ❑ LEAKED ❑ OR DID NOT OPEN ❑ OR DID NOT OPEN ❑ LEAKED ❑
REPAIRS
AND
MATERIALS
USED
v..
FINAL CLOSED TIGHT Cl CLOSED TIGHT ❑ CLOSED TIGHT❑ '
TEST III LBS #LBS OPENED AT_LBS OPEN ED AT_LBS
t LBS
THE ABOVE REPORT IS CERTIFIED TO BE TRUE
INITIAL TEST BY �ZOG CERTIFIED TESTER NO, DATE 3-17-03 •.
MO. DAY YR.
• REPAIRED BY
DATE
FINAL TEST BY CERTIFIED TESTER NO. DATE
MO. DAY YR.
CERTIFICATION OF RE-CLAIMED WATER SYSTEMS �_ •��//��... CROSS CONNECTION SPECIALISTS
CERTIFIED CROSS CONNECTION CONTROL CONSULTANTS BACKFLOW PREVENTION VALVE EXPERT
INSTALLATION-REPAIRS-TESTING-CERTIFICATION
BACKFLOW PREVENTION SPECIALISTS, INC.
LICENSED CONTRACTOR C.C.L.#427328 CALIFORNIA (800)464-FLOW(3569)
3750-E CHARTER PARK DR.,SAN JOSE CA 95136-1356 (408)269-2600
1522-A DAY AVE.,SAN MATEO CA 94403 FAX(408)269-2650
SERVICE ADDRESS 22622 Marlanist Wy.,Cupertino
MAILING ADDRESS ThC MarlanlSt Center CONTACT .SteVC
22622 Marianist Wy TEL# 253-6279
Cupertino,CA 95014
MANUFACTURER MODEL NUMBER TYPE SIZE SERIAL NUMBER
Wilkins 975)CLSE RP 2° 1382169
INTERNAL ❑ TAG LOCATION OF DEVICE mtr#23129255
EXTERNAL
v�
IF DEVICE IS ANEW INSTALLATION PLEASE CHECK THIS BOX[3 PASS FAIL,
• REDUCED PRESSURE DEVICES
PRESSURE TYPE
DOUBLE CHECK VALVES VACUUM BREAKERS
RPP VALVES DIFFERENTIAL
CHECK VALVE CHECK VALVE PRESSURE/RELIEF
N0.1 N0.2
VALVE AIR INLET CHECK VALVE
CLOSED TIGHT ❑ CLOSED TIGHT ❑ OPENEDAT3• V LBS. OPENEDAT_LBS CLOSED TIGHT ❑
INITIAL #IDs. #16s. #LBS #LBS,
TEST OPENED UNDER 2.0 OPENED UNDER 1.0
LEAKED ❑ LEAKED OR DID NOT OPEN ❑ OR DID NOT OPEN ❑ LEAKED ❑
REPAIRS SGS�/�Cc'GS
AND
MATERIALS
USED
FINAL CLOSED TIGHT❑ CLOSED TIGHT El CLOSED TIGHT❑
TEST #LBS #LBS OPENED AT_LBS OPENED AT_LBS
I LBS
THE ABOVE REPORT IS CERTIFIED TO BE TRUE
INITIAL TEST BY�i y�—P CERTIFIED TESTER NO. DATE 3-17-03
�. REPAIRED BY
ROTE MO. DAY YR.
FINAL TEST BY CERTIFIED TESTER NO. DATE
.- MO. DAY YR.
CERTIFICATION OF RE-CLAIMED WATER SYSTEMS CROSS CONNECTION SPECIALISTS
BACKFLOW PREVENTION VALVE EXPERT
CERTIFIED CROSS CONNECTION CONTROL CONSULTANTS
INSTALLATION-REPAIRS-TESTING-CERTIFICATION
SMnrr4ap?w#
BACKFLOW PREVENTION SPECIALISTS, INC.
LICENSED CONTRACTOR C.C.L.#427328 CALIFORNIA (800)464-FLOW(3569)
3750-E CHARTER PARK DR.,SAN JOSE CA 95136-1356 (408)269-2600
1522-A DAY AVE.,SAN MATEO CA 94403 FAX(408)269-2650
SERVICE ADDRESS 22622 Marianist Wy.,Cupertino
MAILING ADDRESS The Manamst Center CONTACT Steve
22622 Marianist Wy TEL# 253-6279
Cupertino,CA 95014
MANUFACTURER MODEL NUMBER TYPE SIZE SERIAL NUMBER
Wim W03920
RP 2° x(003920
INTERNAL ❑ TAG LOCATION OF DEVICE mtr#23129255
EXTERNAL
IF DEVICE IS ANEW INSTALLATION PLEASE CHECK THIS BOX❑ PASS,q,I FAIL❑
• REDUCED PRESSURE DEVICES
PRESSURE TYPE
DOUBLE CHECK VALVES VACUUM BREAKERS
RPP VALVES DIFFERENTIAL
CHECK VALVE CHECK VALVE PRESSURE I RELIEF
N0.1 N0.2VALVE AIR INLET CHECK VALVE
� 7 -
CLOS pTIGHT CLOSED TIOHT� OPENED ATJ•oLBS. OPENED AT_LBS CLOSEDTIGHT ❑
INITIAL #lbs. z #lbs. #LBS #LBS.
TEST OPENED UNDER 2.0 OPENED UNDER 1.0
LEAKED ❑ LEAKED ❑ OR DID NOT OPEN ❑ OR DID NOT OPEN ❑ LEAKED ❑
REPAIRS
AND
MATERIALS
USED
r�
FINAL CLOSED TIGHT❑ CLOSED TIGHT ❑ ,CLOSED TIGHT❑
TEST #LBS #LBS OPENED AT_LBS OPENED AT_LBS IBS
THE ABOVE REPORT IS CERTIFIED TO BE TRUE
INITIAL TEST BY CERTIFIED TESTER NO, z 6 S DATE 3-17-03
• "MO. DAY YR
REPAIRED BY DATE
FINAL TEST BY CERTIFIED TESTER NO. b• DATE
MO. DAY YR.