.01 M-2006-06 Peets Coffee CITY OF CUPERTINO 10300 Torre Avenue, Cupertino, California 95014 DEPARTMENT OF COMMUNITY DEVELOPMENT REPORT FORM Application: M-2006-06 Agenda Date: January 9, 2007 Applicant: Laura Tomas (Peet's Coffee & Tea) Owner: Thomas Harrington, Harprop, Inc. Location: 22350 Homestead Road, APN 326-01-018 APPLICATION SUMMARY: Modification of a use permit (U-2005-11) to allow an opening time of 5:30 AM. RECOMMENDATION: Staff recommends that the Planning Commission: 1. Approve the Modification to the Use Permit (U-2005-11) with recommended changes in accordance with the model resolution. Project Data: General Plan Designation: Zoning Designation: Site Area: Parking: Commercial! Residential P (CG) 32,272 square feet (.74 acres) 47 parking spaces Peel's Coffee Tenant SF: Total Building SF: 1,774 square feet 9,119 square feet Hours of Operation Currently Allowed Hours: Proposed Hours for Peet's Coffee: 7:00 a.m. to 11 p.m., seven days a week 5:30 a.m. to 11 p.m., seven days a week Environmental Assessment: Categorically Exempt BACKGROUND: The applicant, Laura Tomas of Peet's Coffee and Tea, is requesting approval to modify an existing use permit (U-2005-11) to allow Peet's Coffee & Tea shop located at 22350 Homestead Road to begin its hours of operation at 5:30 a.m. Peet's Coffee & Tea is located in a recently remodeled building at the Homestead Shopping Center that is located on the south side of Homestead Road, east of Foothill Boulevard. Homestead Shopping Center is surrounded by single-family residences to the north across Homestead Road, retail commercial uses to the south and west, and multi-family residential condominiums to the east. The applicant was requested by the Planning Department to submit applications to extend hours for both of the Peet's Coffee & Tea shop locations in Cupertino after staff I-I M-2006-06 Page 2 January 9, 2007 became aware in October during the hearings for a Starbucks coffee shop that both of the Peet's Coffee & Tea shop locations were operating earlier than the allowable 7 a.m. DISCUSSION: Peet's Coffee & Tea is requesting approval to operate between the hours of 5:30 a.m. and 11 p.m. daily. Allowed hours are 7 a.m. to 11 p.m., so only the earlier opening time requires approval. The request is consistent with the morning opening time of the adjacent Starbucks Coffee shop that was granted in October by the Planning Conunission. Peet's has already been opening at this time and wishes to continue with these hours. Cupertino's Code Enforcement Division is not aware of any complaints related to its early morning hours at either of its Cupertino locations. Staff Reconunendation Staff is concerned about the early opening hour of 5:30 a.m. based upon this particular tenant's close proximity to surrounding residential uses. Although the applicant is requesting the same opening time as approved for the nearby Starbucks Coffee shop, this particular location is not completely buffered by retail conunercial uses and is directly adjacent to a multi-family residential condominium to the east. The rear of the Peet's Coffee building is constructed along the eastern property line inunediately adjacent to the condominium complex. The Peet's Coffee shop is approximately 55 feet from the nearest residential units on the adjacent property. Staff believes that this closer proximity to residential uses than the Starbucks Coffee shop could create more noise and traffic impacts onto the adjacent residential properties and that it is not good public practice to promote early morning operations next to residential for these reasons. Additionally, staff recognizes that Peet's employees would be arriving earlier than 5:30 a.m. to prepare its opening for the public. Therefore, staff's reconunendation for this application is consistent with the staff reconunendation for the Starbucks Coffee shop, which would be to reconunend the following hours of operation: Monday through Sunday, 6:00 a.m. to 11:00 p.m. However, the Planning Commission may consider the applicant's request for a 5:30 a.m. opening time that is consistent with the approval the Commission granted to the nearby Starbucks Coffee shop in October. Should the Conunission approve any early morning opening time, staff also reconunends that a condition of approval be added that is the same condition for the Starbucks approval. The condition, which was added due to neighbor concerns about impacts of expanded hours of operation, is: ,---) M-2006-06 CITY OF CUPERTINO 10300 Torre Avenue Cupertino, California 95014 MODEL RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF CUPERTINO APPROVING A MODIFICATION TO A USE PERMIT (V-2005-11) TO ALLOW A COFFEE SHOP (PEET'S COFFEE & TEA) TO BEGIN HOURS OF OPERATION AT 5:30 A.M. IN AN EXISTING COMMERCIAL RETAIL BUILDING SECTION I: FINDINGS WHEREAS, the Planning Commission of the City of Cupertino received an application for a Use Permit Modification, as described in Section II of this Resolution; and WHEREAS, the applicant has met the burden of proof required to support said application; and WHEREAS, the Planning Commission finds that the application meets the following requirements: a) That the use is in conformance with the General Plan of the City of Cupertino, and is not detrimental to existing uses or to uses specifically permitted in the zone in which the proposed use is to be located. b) That the property involved is adequate in size and shape to accommodate the proposed use. c) That the proposed use will not generate a level of traffic over and above that of the capacity of the existing street system. d) That the proposed use is otherwise not detrimental to the health, safety, peace, morals and general welfare of persons residing or working in the neighborhood of such proposed uses, nor injurious to property and improvements in the neighborhood. NOW, THEREFORE, BE IT RESOLVED: That after careful consideration of maps, facts, exhibits, testimony and other evidence submitted in this matter, the application for use permit is hereby recommended for approval, subject to the conditions which are enumerated in this Resolution beginning on Page 2 thereof; and That the subconc1usions upon which the findings and conditions specified in this resolution are based and contained in the public hearing record concerning Application M-2006-06 as set forth in the Minutes of the Planning Commission Meeting of January 9, 2007, and are incorporated by reference as though fully set forth herein. SECTION II: PROJECT DESCRIPTION Application No.: M-2006-06 Applicant: Laura Tomas (Peet's Coffee & Tea) Location: 22350 Homestead Road ,~~ Model Resolution Page-2- M-2006-06 January 9, 2007 SECTION III: CONDITIONS ADMINISTERED BY THE COMMUNITY DEVELOPMENT DEPT. 1. PREVIOUS CONDITIONS OF APPROVAL All prior use permit conditions for U-200S-11 shall remain in effect, unless in conflict with the conditions of approval for M-2006-06. 2. HOURS OF OPERATION Hours of operation shall be 6:00 a.m. to 11 p.m. daily (Monday through Sunday). 3. COMPLAINTS In the event the City receives a complaint after the establishment of these approved hours of operation, review of this use permit may be brought back to the Planning Commission for a hearing to consider addition of mitigation measures that may include reduction of hours of operation. 4. NOTICE OF FEES, DEDICATIONS, RESERVATIONS OR OTHER EXACTIONS The Conditions of Project Approval set forth herein may include certain fees, dedication requirements, reservation requirements, and other exactions. Pursuant to Government Code Section 66020(d) (1), these Conditions constitute written notice of a statement of the amount of such fees, and a description of the dedications, reservations, and other exactions. You are hereby further notified that the 90-day approval period in which you may protest these fees, dedications, reservations, and other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest within this 90-day period complying with all of the requirements of Section 66020, you will be legally barred from later challenging such exactions. PASSED AND ADOPTED this 9th day of January 2007 at a regular meeting of the Planning Commission of the City of Cupertino, State of California, by the following roll call vote: AYES: NOES: ABSTAIN: ABSENT: COMMISSIONERS: COMMISSIONERS: COMMISSIONERS: COMMISSIONERS: ATTEST: APPROVE Steve Piasecki Director of Community Development Marty Miller, Chairperson Cupertino Planning Commission glp lanning/pdreportlres/2006/M - 2 006-06 1~5 VICINITY MAP \~~~:~~~..;~, !~:!"", ,'U ,t'iL~EI'~J!.i_!~~~~l " '1-c"-"'--." "-"~ , ""'", "'-'" ',',-" "',,-,4, ''=I''---'~,,' ",-','--,'---',','-", ~,,~~~-.. ,~'-~>~~-) i')lo'ii ii~!tdi!~:, ~~i~~~iii:i.ti J;~...., .. ,'~.. 7\ / e::,J ',-" ",~.jp......~, F' -;.;~ \ ,_;~," ~', ~" b ~,~~ ;,:~~c~_ -~'~:~\\~;~(~b--}~~lP.;:;;'J~j ':",-"".~~. ~....'(.>':; :0;-,1(' \ HI _;~:!","I..-ilICt J'f~~i~I:t:~~~<t,;.~r ~~. ~,;. ~. \ KEy PLAN IW)<:ioUlMGUllill .~~ AJWSHIU.. -"'-""'" .,. 'OI'1,S1WIU ." . .i! 1 ~ :I: z8 STOCK: 362 SFI 300 LOAD FACTOR .2 ocaJPANTS GENERAL NOTES I. GENERAL CONTRACTOR SHALL REVIEW THE CONTRACT DOCUMENTS AND VERIFY ALL DlMENSIONS AND CONOmONS ON THE JOB SITE PRIOR TO EXECUTING THE WORK. CONTRACTOR SHAll NOTIFY THE ARCHITECT AND/OR OWNERS REPRESENTATIVE IMMEDIATELY OF ^NY DISCREPANCIES GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR All COSTS INCURRED DUE TO HIS FAlLURE TO 0050, 2. PERMIT EXPEDITER OR GENERAL CONTRACTOR SHAlL BE RESPONSIBLE FOR ALL FEES. PERMITS, UllU1Y CONNECTION FEES AND OTHERASSOClATED COSTS AS REQUIRED BY GOVERNMENT AGENQES OR 1.1TllITY COMPANIES. 3. PERMIT EXPEDITER OR GEN'ERAl CONTRACTOR SHAll BE RESPONSIBLE FORAll COSTS REQUlRED BY THESE CONTRACT DOCUMENTS OR GOVERNMENT AGENCY IN REGARD TO INSPECtlON. 4. All WORK AND MATERlALSHAll BE EXECUTED IN FULLACCORDANCE WITH ALLAPPUCABLE CODES. 5. GENERAl CONTRACTOR SHALL PROVIDE AND BERESPONSI8LE FORAllCOSTS FOR P'UBUC PROTECTION AS REQUIRED BY THE CONnACT DOCUMENTS AND LOCAL GOVERNMENT AGENCIES. 6. EXTERlOR SJGNAGEAS SHOWN ON THESE DOalMFNTS IS FOR CONVENIENCE ONLY AND ANY PERMtTS REQUIRED SHALL BE UNDERA SEPARATE CONTRACT. 7. FlRE EXTINGUISHERS AND CABINETS AS REQUIRED BY LOCAL GOVERNMENT AGENCY SHAlL BE PROVIDED BY GENERAl CONTRACTOR AND INa..UDED IN COrrrRACT. 8. GENERAl CONTRACTOR SHALL MAKE NO REVISIONS, ALTERATIONS OR CHANGES TO THE WORK AS SHOWN IN THE CONTRACT JX>CUMENTS WITHOUT THE PRIOR WRITTEN APPROVAL OF THE ARCHITECT AND/OR OWNERS REPRESENTATIVE. NO ADOmONAl COSTS FROM THE GENERAL CONTRACTOR SHALL BE CONSIDERED AND THE WORK MAY BE REQUlRED TO BE REMOVED WITHOUT SUCH APPROVAl BY ARCHITECT. 9. GENERAl CONTRACTOR SHALL PROVIDE THE BUILDING OFFJClAL WITH A CERTIFICATE OF CONSTRUcnON COMPlJANCE WITH ENERGY CONSERVATION STANDARDS UPON FINAl BUIlDING DEPARTMENT INSPECTIONS (WHERE REQUIRED), 10. GENERAL CONTRACTOR SHALL PREPARE THE FlOOR LEVEL AND SMOOrn AND PROVIDE FOR mE FIlliNG OF All FLOOR DRAIN'S, FLOOR SINKS OR OTHER SUCH DEPRESSIONS, CRACKS OR IRRF.GUL\RITlF.S IN FLOOR SlAB. 11. GENERAL CONTRACTOR SHAI.L PROVIDE ACCESS PANElS FORAll TRADES AS REQUIRED BY CODE. LOCATIONS TO BE APPROVED BY ARCHITECT ANDlOR OWNERS REPRESENTATIVE PRlOR TO EXECUTION OF WORK. 12. CONTRACTOR IS TO VERIFY All DIMENSIONS AND EXISTING CONDmONS ON THE SITE AND BE RESPONSIBLE FOR CONFIRMING AND CORJt.El.A~G All QUANTITIES AND DIMENSIONS, SELECTING FABRICATION PROCESSES AND TECHNIQUES OF CONSTRUcnON, COORDINATING HISlHER WORK WITH All OTHER TRADES AND PERFORMING HlSIHER WORK IN A SAfE, COMPLETE. AND SATISFACTORYMANNEJL 13. All WAll DIMENSIONS ARE F.O.F. TO F.O.F., U.O.N. 14. PR.OVIDE BLOCKING AT WALLS WHERE REQUIRED FOR. SUPPORT OF SHEI.:VThlG. 15. All EXITS TO BE OPENABLE FROM INSIDE WITHOUT USE OF A KEY. -e PROJECT TEAM 0...../ PraJc<t ~t 1400 ParkA....cnuc EmeryviJk. CA 94608 F"" (510) 594.2180 Cont2a: Julio Guerrero Phol1C: (510) 594-3242 ContaCt: Nouman Tarabichi PhOI1C: (510) 594-2111 SHEET INDEX AO Covet Sheet A2 Floor Plan A4 Rdleaed CdliDg Plan A5 FiDishPlan A6 Interior Elevations A6.1 Exterior Elevations A7 Detaas A7.1 DeWIs KI EqwpmCD[ Plan K2 Eqwp...m Schedule ASPI-8 Specific:ariollS &: leam en.... AtdIIaaate 85 Bolinas Road Suite 17 Fairtax. CA 94930 Pho." (41~)453-07oo Fax, (41~) 4~3-O785 ContaCt: Mu Yun Otang LaadIanl, '" I...~ Harrington Properti~ 10S Fremont A....c. Suitc B Los Ahos. CA 94022 PhoD" (650) 941-6922 F"" (650) 941-6908 Contaa: lbomas E. Haningron 1iItdIoaIoII/1!IemIool........ MIchaud Cooley Erid<soD 1200 McttDpolitan Centte 333 Sooth Seventh Su= MmneapolIs. MN 55402 Ph""" (612) 673-6834 F= (612) 339-8354 Contact, R;ck I...... M I MtchanIal Specific:ari... Load Summary & Drawing I.dex M2 Ajr Handling Systems Checklist M3 HV AC Plan & Schedules M4 MtchanIal Detail. M5 Tttle 24 Fonns PI PlumbIng SpecificatiollS P2 FruhWa{t:J'Plan. Wutt&VemPbn P3 Rise< D"gwm & Detail. EO Elearital Symbols Legend and Specific:ariOD E I Elearital Ughting Plan E2 Elearital P..... & Systems Plan E3 Elearital Detalls E4 Elearital Rise< Dl2gtam and !'2nd Schedules E5 Low VDluge Diagnm E6 CalIfornia TIde 24 PROJECT DATA PIOjI!CI' ADDIIlSS: 22350 HOMESTEAD RD. CUPERTINO. CA 9-4014 _ 326-01-018 SCOPE OJ! WORK: INTERJOR TENANT IMPROVEMENT. CXlDISI CBC 2001. TI11-E 24. NEC 1999. CEC 2001, CPC 2001, CMC 2001, UFe 1998. CURFFL 2003 IIUIlDING TYPE: Y.N um ReWI OCCUPANCrGROUP, B I!XISTING Sf, 1.720 SF (LOD) . OJ! STOBII!S, I OCCUPANCrLOAD CALCUIA11ON: OCCUPANCY AlUlA LOAD PACI"OR . OCCUPANTS RETAIL SEATING EMPLOYEE STOCK 398 290 134 362 30 I~ 200 300 13 19 I 2 TOTAL 35 I!XrI'S: Number Df...a requited, I Number of exits provided: 1 Exit w;dth Jeljuited, 36" miD Exit wIdth provided, greatct than 36" Environmental Health Notes: I. All food items to come from an inspected and approved source. 2. A copy of the menu is included with the equipment CUt sheets. No potentially hazardous foods will be served, Faaory ptep:ued and wrapped pastries and candies made elsewhere will be served. No food will be reheated. No multiple step ptocessing will be used. Assembly of drinks may involve mixing of milk (stOred in ",ftigetators), flavot syrups, and similar items, No other foods will be mixed ot assembled, REsPONSIBIUTY SCHEDULE ON. OWNERNENDOR c. GENERAl. CONTR. L- LANDLORD Ez EXISTING , '" 'IWNISH I !INSTAU. I UWABS "DlUIIDI S1GNAG1! l'J'.~ii2nSlir B . star' C.C. PROVIDES CYUNDW LEVEL 5 FnJISH AT p~ AS REQUIRED BY CODE. LL RESPONSIBLE FOR PATCHES AT U. WOI HAllDWARE BY GC nonillum.) N,^ .' :::::~~:~vinyWUlDhiG I . C.C TO PltOVlDE I'CITD.. J.IOX, AND noo:JNG IIl'IDIll& JILlXaCllYlllNG ~ " ~ae ICOUOI isuenOJ' furniture ~~nn IWI IaIUBIlT IYIa'SIlIISII:/STOCIi wirineutda:rminatiOl1 NO'I1lSo ~, 1HSTAl1.ER TO PlOVlDEQUAN'nTlU FOR VDUFlCAnON iPE n: FINISH SCHEDULE FOR SPECIFlc:ATION ;EE FINISH SCHEDULE FOR SPECIFICATION ;EE FINISH SCHEDUll FOR SPECIFICATION & com. EXTER.lORSEATlNG UNDER SEPARATE PERMIT INCL. BOLTING TO TH-E WAll WHERE REI OCTOPJlOVID[f"CONCREn~AD"IlOLTOOlI'N~ CCTOADOHlWSAR'{K"'-D'II'.oJl.tA.51lEQUl1lED 1.5 REQUIRED BY CODE GCTOASSEMIUI'lI,EQIJIIW> SEE FINISH SCHEDULE HARDWARE NEW BY G.C. PXiN"fBVG.C . I SEESHEETM.I FORFIXl1JRESCHEDULE lainl IUIoEOtANIC\l.SHEml'Oll.SCOPiOFWI)I,K .15El~SHU:T$FOll$COPlOF'II01.K SE1~SHUTSI'Oll.5COftOF_ SElloECHAHJCALSHEEnl'Oll5COftOF WOQ; Siill4OtAHlCALatEEnI'ORSCOPtOF'W()IU;: mr.aow<<:ALSHUTSI'Oll.$CDPtOFWOIU: 22350 Homestl Cupertino, CA DO Set 01 13 CD Set 02 03 6, 0308 ~ .~ ~ ~ ;f . J: ] ~ .~ '0 .. ~ ~ -#/ ~I lEA DEADBOLT#B6tiOR '" sa<!AGE ~ 2EA PlJU..#Jl 61l neE >PAIl BUTTS 4-I1r X +lIr #BBJ79 NRP S!ANIE{ 0 DOOIl 2EA ICICXPlA.TlIO"' X,... 18400 61l MS c:r:: 2 2EA a.ow. ."...DA USIO) NOATON ~ 6EA SlLENaJll21 GIlAY MS lEA nlUSHOW NarE., PEM1CO I ~ 2EA FLUSH EXTENSION BOLT #SOlO ALUM. BBW BArn I lEA PRNACY lOCK SET ID40S 613 SCHLAGI'. DOOR RHODts i blJTT~ ~ I Slr."l:r. , ClOSEIl. .t7~oo.u," I U5'" I NORW.' WAll.STOP*<109.)/2 BlOB ~'E5 SJUNCER,.21 GRAY MS COATHOOK(ATRE.STR..DOORSj MalOl MS #S7](MOUNT" +6'~' AF.F.) KtCKPI.An JO"'X"'"18400 ~ .. l!! ~ lEVER OPERATEP LOCK SET 1I'S021S-1P1.. (SCHlAGE. COMPATlBU) l~lI2PAIR Bl1TTS~112"X4.1f2~ 'BB179 N1U' 1613 2EA JOCKPUTE JfnGf"184OO B.B lEA a.osERl7500-0A USIOB lEA WAll sro,lI!409-112 BlOB 3EA S1!.I!>ICEIl121 GRAY lEA PEEP HOLE #U691B 1 OB ,,^ DEAD BOLT ft66OR. Haxdware Notes AU. LOCKS TO BE SOiLAGE lNTER.CiANGEABLE CORE. SUBMIT THREE (3) COPIES OF HARDWARE PRODUCT" DATA AND HARDWARE SCHEDUl.E.S FOR..AR.OIIttCI"S/'O'fINER.'S REVIEW PRlOI!. TO PURQiASE OF HARDWARE. R.EVU:\I1 AU KEYING ON sm 'WITH 0WNEIl DOORS TO COMPLY WI lAC400JIOij) AND HAVE!' DOOll.lEVER OPERAnD OREQUAl DOOR.HARDWAk!.ll" ONntEPUll.SIDE.AND A 5 LIl MAX. FORCE TO OPEN ON ALL HINGED EXI'ElJOlNID INlRIUOR DOORS. So VERJFY SADDLE TYPE I RNlSH B I MATCH TO FRAME. SIZE. { VERIFY OFFSETTO SITE CONDmoNS I l SJi..\Dm ITEMS NOT l1SEDS. TYP. Door Schedule NO. SIZE I OOOA I FRAME THDWR Fl1UNG DErAILS AEMAJUCS TIP MAT MAll H }MB SET RATING THR HD JMB ] OOSTING A ALUM! ALU ALU AW 2 5/A7 A.D.E 6'..()"z 7...(1' GlA<< 2 3'.0" x 7-0' C sew MTL IMTl IMTI ; <JA7 4/A '.F ; 3'-O~:r7...o' C sew MTL IMTl IMTI 3 4/A7 <JA '.F , 3'..()"z:7-63/4" D ALUM. MTL IMTl MTL MFA IsEEbR.mES FOR SPECS \ OOSTING . sew MTL IMTl MTL \ 5JA7 A.D.E 3'...0"& 7..0" ....hbreviations ~ ALUMINUM Fr: FACTORY FOOSH :oL-) TEMPEJW) GlASS tiC HOllOW CORE HW HOllOWMETAl lrln METAL P PAINT SC SOUD CORE 55 STAINLESS STEEl sew SOUO CORE WOOD YO WOOD Remarks ,... . MAINTAIN (E) DOORS" HARDWAlE.ASSESS CE) DOOR HARDWARE&. FIELD DETERMINE EXTEND OF MODIFICATION TO fE) HARDWAR,E TO MATCH THE HARDWARE GROUP SPECIFIED IN SCHEDULE. B -UNDERClTT 3W. FOR ADA SICHACE SllDETAlL8, SHEET AJ. :: . FOR PANT KEY AND Sl'!C. SEE SHEET AS, PlNISH PLAN AND SHEm A6, INTERIOR ELEVATIONS. D . EXIT DOORS ARE TO BE OPENABU FROM INSIDE WITHOUT" USE OF ^ KEY. SPBClAL KNOWLEDGE :>Il. EFFORT. KEY LOCKING HARDWAkEMAYBE USED ON THE MAIN EXIT WHEN THE MAIN EXIT DOOR HAS A Dl1JI.ABl.E SIGN ON OR ADJACENT TO TIlE DOOR STATING: nus DOOll MUST IU!.MAIN UNl..OCEED DUIUNG IUSJN!SS HOUU. THE SIGN SHALL BE IN l.ETI'ERS NOT LESS THAN ONE D\lCH HIGH ON A CONJ1tASTlNG BACKGROUND. E . UNl.ATCHING FORCE.. OR OPENING FORCE. NOT TO EXCEED 5 POUNDS. (CALIFORNIA) F . PAINT DOOR e:. FRAME 0 ;; . PAINT DOOR A: FRAME0 Stl'~7' VJ~. DODD '" '" 44" MlN '" (E) MECH ROOM, N1C 8'.11- @HOME .. ADJACENT SPACE " '" ~~~ (i) """,PI.. ~ \14" .\'-0" A Wall Legend Floor Plan Key Notes (continued) @ RECESSED ELECTRlCAL PANELS @ NOT USED @ HOT WATER AND DRAIN PIPES ACCESSIBLE UNDER L.A.vATORJES SHAll BE INSUlATED OR OTHERWISE COVERED. THERE SHAll BE NO SHARP OR ABRASIVE SURfACES UNDER L,AVATORJES. SEC 1115B.2.1.2.2 @ UGHTING CONTROLS @ PRIMARYDATIJMAND DIMENSIONSTAlCEN FROM FACE OF CYP. BOARD @ 6" INTEGRATED SPLASH GUARD @ NOT USED (E) TENANT DEMISINC WAll.. BY lJINDLORD. EXISTING WAll. PATCH AND REPAIRAllGYP. BO. AS REQUIRED FOR NEW FINISH (N) NON-RATEDWAll3-5Ir 20GAMEI'ALm.IOS@16"O.C.W/518"GYP.BO.ON BOTH SIDES (V.C.N.) PROVIDE R.ll BATT. INSUU.TION@RESTRooMWALlS. WAll TO 6" ABOVE THE CEILING W1BRACIN"G TO STRUCTURE ABOVE. AT MOP SINK LOCATION.WAll. TOPUTFORMABOVE.. S,EEDETAILI1JA]. (N) NON-RATEDWAll6"lOGAMETALSTUDS .2"" O.C.WI S18~ GYP. BO. ON BOTH SIDES (GYP. BD. ON ONE SIDE BEHnm THE WATER.a.DSET@WOMEN'SRESTROOM) PROVIDEINSt1U.TION@R.ESTROOMWAllS. WAll T06~ ABOVE THE CEILING W!BRACING TO STR.UCTUR.EABOVE.. SECURE TO FRAMING ABOVE. REF. DETAIL l/A] 5IM1lAIl IN) FtJRRED WAll 3 518" OR2112" 20 GA METAL S'J11DS AS REQUIRED WI 518" GYP. BD. ON INT. SIDE AND 114 WHITEMEI.AMINEON EXT. SIDE. PAINT SCREWS TO MATCH. WAll. TO 6- ABOVE THE CEllJNC W/BRACING TO STRUCTUR.E ABOVE. SECURETO FRAMU'IIG ABOVE. W. DErAIL I/A7 SIM1U.R. @ NOT USED @ 36"W CASED OPENING @ PARTIAL HT. wAll. FOR WATER HEATER. PUTFORM. REF. DET. 3/A7.1 @ NOTUSED @) DOUBLEACfING SWlNGCATE VlIO LATCH. SEEALSO INTERIOR ELEVATION HA6. I I Floor Plan General Notes 1. CONCRETE. SUB TO BE PROVIDED FOR EXTERIOR TRASH. GAllBAGE. AND GREASE 8AR.REl STORAGE. THE WAllS ENCLOSING THE AAEA SHALL BE SMOOTH, SEALED AND WASHABLE (E.G.. PLASTERED SMOOTH AND PAINTED, ETC.). CONTRAcrOR SHALL VERlFYTHAT ALL PENETR.A.TIONS WILL NOT COMPROMISE THE STRUcruRAllNTEGRlTY OF THE EXISTING SLAB X-RAY OF EXlSTING CONomONS MAY BE REQUlllED (V.LF.). Door Types ._____L__. .____c~: 200 SQ. IN VIEW WINDOW ., ;., " " \1/ " C S'WlNG AS SHOWN ON PUN D ELIASON LTP.,AWM"...VM DOUBLE SWlNC. NO lATOI ~~~~D~r. SWING ~ SHOWN ON PIN< Floor Plan Key Notes CD H.ANDICA.PACCESSIBLE5EA~G o ACCESSIBLE COUNI'ER. AREA o CENTER.UNE OF BEAN SALES MENU (ITEM C.2) TO AUGN W, CENrElUlNE OF BEAN DISPLAY MODULE (ITEM M.I) BELOW. o CENTERLINE OF DRJNKSALES MENU (ITEM G.l) TO AUGN VII CENTER.LlNE.OF PASTRY CASE ANDI0R URN CAlmEr (ITEM 5.5) BELOW. CD SECURE CAB TO WALL REF. DET 6/A7.1 o 1"~ll28-a.EARAREAFORCRATES (2) WATER HEATER. PLATFORM ABOVE.. STRAP WATER HEATER TOTHEWAll. SEE DETAIL 9/A7.1 o 5- Hx15 112- Wx18~ D CONCRETE PAD BELOW SAFE ~ H.4). VE.RlFY EXACT SIZEAND LOCATION PRIOR TO INSTAl.lATION. SEE DETAD..10lA7.1 o (N) THERMOSTAT (SEE MECHANICAL DRAWINGS) @ eN) REMOTE SENSOR FOR THERMOSTAT (SEE MECHANlCALDRAWINGS) @ REF.61A7.1 fQRSHELVINGSUPPORTS. @ ANCHOR GRAB BARS TO FRAMING, TYP.SEEDETAlL6IA7 @ PROVlOEI"''TERNATIONALSYMBOLOF ACCESSIBIUTI' PER DHAI~.7/A7. ~~l L/ Peets 22350 Homestead Road CupertiDo. CA 94014 DD Set 01 13 06 CD Set 02 03 06 ,& 03 08 06 ~ ~ E ~ ~ M .., ~ u ~ GJ ~ .., I- e .r::. ~ ~ .. '-' n <t ~ ~ Jl GJ ... E ~ n 0 c '0 L. a> ~ U '" ; ~ ... o o E: ~.