Loading...
BLD-2023-1990_CF1RRegistrationNumber:223-A026581626A-000-000-0000000-0000 RegistrationDate/Time:   HERSProvider:CalCERTS CA Building EnergyEfficiencyStandards -2022 Residential Compliance Report Version:2022.0.000 Schema Version:rev 20220101 Report Generated:2023-08-31   14:28:42 ALTERATIONSTO SPACE CONDITIONINGSYSTEMS (FORMERLY CF-1R-ALT-HVAC) CF1R-ALT-02-E (Page1 of3) CERTIFICATE OF COMPLIANCE ProjectName: 21163 Gardena Drive EnforcementAgency: Cityof Cupertino Dwelling Address: 21163 Gardena Drive PermitNumber: TBD City and ZipCode Cupertino, 95014 PermitApplication Date: A.General Information CF1R-ALT-02 is applicable to multiple space conditioning systems contained withina single dwelling unit. 01 ProjectName 21163 Gardena Drive 02 DatePrepared 2023-08-31 03 ProjectLocation 21163 Gardena Drive 04 Building Type Single family 05 CA City Cupertino 06 Dwelling UnitName 21163 Gardena Drive 07 ZipCode 95014 08 Dwelling UnitConditioned Floor Area (ft2)1100 09 ClimateZone 4 10 Number ofSpaceConditioning (SC)Systems in this Dwelling Unit: 1 B.SpaceConditioning (SC)System Information 01 02 03 04 05 06 07 08 09 10 SC System ID or Name SC System Location or Area Served CFA served by this SC System (ft2) Is theSC system a ducted system? Installing a refrigerant containing component? Installing new SC system components? Installing more than 25 feetof ducts? Installing entirely new ductsystem? Installing entirely new SC system?Alteration Type Wallace Chan Location1 1100 Yes Yes Yes No No No Altered space conditioning system 2023-08-31 14:28:42 Arnold Hom 09/11/23 ALTERATIONSTO SPACE CONDITIONINGSYSTEMS (FORMERLY CF-1R-ALT-HVAC)CF1R-ALT-02-E (Page2 of3) RegistrationNumber:223-A026581626A-000-000-0000000-0000 RegistrationDate/Time:   HERSProvider:CalCERTS CA Building EnergyEfficiencyStandards -2022 Residential Compliance Report Version:2022.0.000 Schema Version:rev 20220101 Report Generated:2023-08-31   14:28:42 C.Extension ofExisting DuctSystem,Greater Than 25 Feet(Section150.2(b)1Diib) This sectiondoes not applyto this project. D.Altered SpaceConditioning System (Sections 150.2(b)1E and F) 01 02 03 04 05 06 07 08 09 010 11 12 13 14 System ID/ Name SC System Description ofArea Served Heating System Type Altered Heating Component s Heating Efficiency Type Heating Minimum Efficiency Value Cooling System Type Altered Cooling Component s Cooling Efficiency Type Cooling Minimum Efficiency Value SEER/SEER2 Cooling Minimum Efficiency Value EER/EER2/C EER Required Thermostat Type New or Replaced DuctLength New Duct R-Value Wallace Chan Location1 Central gas furnace All new heating components AFUE 80 Central split AC All new cooling components EERSEER 14 11.7 Setback n/a n/a Required Documentation: CF2R-MCH-01-E -Space Conditioning Systems -Duct insulationrequirement for the new portions of supply-air and return-air ducts or plenums:R6 (CZ3, 5-7)and R8 (CZ1, 2, 4, 8-16) CF2R and CF3R-MCH-20-H -Duct Leakage Test required whenheating or cooling components are installed inducted systems, or whenmore than25 ft of duct length is replaced -Leakage rate compliance:less thanor equal to 10%or less thanor equal to 7%leakage to outside, or seal all accessible leaks. CF2R and CF3R-MCH-25-H Refrigerant Charge verificationrequired whenrefrigerant containing components are installed or altered (applicable inCZ2, 8-15). CF2R and CF3R-MCH-23 Airflow Rate greater thanor equal to 300 CFM per tonrequired whenMCH-25 is required. Exceptions: -Duct systems registered with HERSprovider as previouslysealed are exempt from MCH-20 Duct Leakage Testing requirements. -Heating-onlysystems and Air Handler Furnace changes do not require verificationof Air Flow MCH-23, or Refrigerant Charge MCH-25. -Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH-20 Duct Leakage Testing requirements. E.Entirely New or CompleteReplacementDuctSystem,with or withoutEquipmentChangeout(Sections 150.2(b)1Diia and 150.2(b)1E,F) This sectiondoes not applyto this project. F.Entirely New or CompleteReplacementSpaceConditioning System (Section 150.2(b)1C) This sectiondoes not applyto this project. 2023-08-31 14:28:42 ALTERATIONSTO SPACE CONDITIONINGSYSTEMS (FORMERLY CF-1R-ALT-HVAC)CF1R-ALT-02-E (Page3 of3) RegistrationNumber:223-A026581626A-000-000-0000000-0000 RegistrationDate/Time:   HERSProvider:CalCERTS CA Building EnergyEfficiencyStandards -2022 Residential Compliance Report Version:2022.0.000 Schema Version:rev 20220101 Report Generated:2023-08-31   14:28:42 DOCUMENTATION AUTHOR'SDECLARATION STATEMENT 1.I certifythat this Certificate of Compliance documentationis accurate and complete. DocumentationAuthor Name: CindyFaulkner DocumentationAuthor Signature: Company: ATKINSON CLIMATROLLERSINC dba VALLEY HEATING,COOLING &ELECTRICAL Signature Date: Address: 1171 NORTH 4TH STREET CEA/HERSCertificationIdentification(if applicable): City/State/Zip: SAN JOSE CA 95112 Phone: 408-294-6290 RESPONSIBLE PERSON'SDECLARATION STATEMENT I certifythe following under penaltyof perjury, under the laws of the State of California: 1. The informationprovided onthis Certificate of Compliance is true and correct. 2. I am eligible under Division3 of the Business and Professions Code to accept responsibilityfor the building designor system designidentified onthis Certificate of Compliance (responsible designer). 3. The energyfeatures and performance specifications, materials, components, and manufactured devices for the building designor system designidentified onthis Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building designfeatures or system designfeatures identified onthis Certificate of Compliance are consistent with the informationprovided onother applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agencyfor approval with this building permit application. 5. I understand that a registered copyof this Certificate of Compliance shall be made available with the building permit(s)issued for the building, and made available to the enforcement agencyfor all applicable inspections, and I will take the necessarysteps to accomplish this requirement. 6. I understand that a registered copyof this Certificate of Compliance is required to be included with the documentationthe builder provides to the building owner at occupancy, and I will take the necessarysteps to accomplish these requirements. Responsible Designer Name: CindyFaulkner Responsible Designer Signature: Company: ATKINSON CLIMATROLLERSINC dba VALLEY HEATING,COOLING &ELECTRICAL Date Signed: Address: 1171 NORTH 4TH STREET License: 258540 City/State/Zip: SAN JOSE CA 95112 Phone: 408-294-6290 Easy to Verify at CalCERTS.com 2023-08-31 14:28:42 2023-08-31 14:28:42 Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 2023-08-31 14:28:42